Always consult electronic master. Paper copies are uncontrolled.
Contents............................................................................................................................................................................................. 1
Foreword ........................................................................................................................................................................................... 1
1.0 Scope ..................................................................................................................................................................................... 1
2.0 References............................................................................................................................................................................ 2
3.0 Concessions ......................................................................................................................................................................... 2
4.0 Assessment method for permissible imperfections ................................................................................................... 2
5.0 Surface classifications......................................................................................................................................................... 2
5.1 Definitions............................................................................................................................................................ 2
5.2 General requirements ....................................................................................................................................... 2
6.0 Defect types......................................................................................................................................................................... 3
7.0 Physical tests........................................................................................................................................................................ 6
Foreword
This standard has been prepared under the authority of the JCB Research Standards department.
This standard is intended solely for use in connection with the business requirements of J C Bamford Excavators
Ltd. (JCB) and is for use by appropriately qualified and competent people.
This is the fourth issue of this standard, which has been up-issued to include specific HBU requirements in clause
7.0 item 20.
Contractual and legal considerations are not part of the scope of this standard. This standard does not
relinquish any responsibility, regulatory requirements or duty of care.
1.0 Scope
This standard specifies the minimum acceptance criteria for the appearance of painted surfaces on JCB products.
This standard is applicable to all JCB painted products.
This standard does not apply to non accessible and non visual areas of a component, these are exempt from
surface appearance requirements. Typically non visible areas of the vehicle are interior of booms and closures
etc.
THIS DOCUMENT IS THE PROPERTY OF J C BAMFORD EXCAVATORS LTD. IT MUST NOT BE COPIED, REPRODUCED OR TRANSMITTED WITHOUT PRIOR WRITTEN CONSENT
2.0 References
This standard incorporates provisions from other standards. These references are cited at the appropriate
places within the text and are listed hereafter. For undated references, the latest edition applies.
Always consult electronic master. Paper copies are uncontrolled.
3.0 Concessions
In the case of a failure to conform to the requirements of this standard, a documented concession should be
generated. This concession shall clearly state:
- title and name of person requesting the concession.
- the reason why the concession is being requested.
- summary of action in place to ensure that concession will be corrected within a specified time.
- title and name of director who is authorising concession within the business unit.
A digital copy of the concession shall be filed with JCB Standards department.
5.1 Definitions
Surfaces shall be characterised in respect to their visual impact upon the perception of the vehicle. Classification
shall be based upon 4200/0000. These are:
Class ‘A’ surfaces that have a high visual impact upon the perception of the product.
Class ‘B’ surfaces that have a visual impact upon the perception of the product.
Class ‘C’ surfaces that have no visual impact upon the perception of the product.
THIS DOCUMENT IS THE PROPERTY OF J C BAMFORD EXCAVATORS LTD. IT MUST NOT BE COPIED, REPRODUCED OR TRANSMITTED WITHOUT PRIOR WRITTEN CONSENT
A B C
Defect shall NOT be
visible at stated
viewing distance (m)
1 Handling / Any damage, scratches, ≥ 1.0 ≥ 1.5
processing gouges, entrained
damage in base millscale from handling
material or manufacturing
processes
THIS DOCUMENT IS THE PROPERTY OF J C BAMFORD EXCAVATORS LTD. IT MUST NOT BE COPIED, REPRODUCED OR TRANSMITTED WITHOUT PRIOR WRITTEN CONSENT
visible at stated
viewing distance (m)
6 Orange peel Poor flow of coating ≥ 1.5 ≥ 3.0
surface giving
appearance similar to an
orange peel
THIS DOCUMENT IS THE PROPERTY OF J C BAMFORD EXCAVATORS LTD. IT MUST NOT BE COPIED, REPRODUCED OR TRANSMITTED WITHOUT PRIOR WRITTEN CONSENT