Development of A Hydraulic Component Leakage Detecting System Usi
Development of A Hydraulic Component Leakage Detecting System Usi
UNI ScholarWorks
2015
Recommended Citation
Shang, Xuanju, "Development of a hydraulic component leakage detecting system using pressure decay
signal" (2015). Dissertations and Theses @ UNI. 219.
https://scholarworks.uni.edu/etd/219
This Open Access Thesis is brought to you for free and open access by the Student Work at UNI ScholarWorks. It
has been accepted for inclusion in Dissertations and Theses @ UNI by an authorized administrator of UNI
ScholarWorks. For more information, please contact [email protected].
DEVELOPMENT OF A HYDRAULIC COMPONENT LEAKAGE DETECTING
An Abstract of a Thesis
Submitted
in Partial Fulfillment
Master of Science
Xuanju Shang
December 2015
ABSTRACT
and then further assembly of hydraulic components with leakage problems can be
avoided. Integrating a USB based microcontroller and a pressure sensor; this study
developed a hydraulic leakage detection system in using air instead of hydraulic oil as
medium, through measuring pressure decay signals captured by a real time data
acquisition system. Compared with the conventional hydraulic system using oils, this
system shows advantages in safety operation and little environmental concerns due to use
The low-cost hydraulic leakage detection system was developed can record and
visualize the system pressure in real time. Experimental tests were conducted to test this
system performance. The pressure decay of the hydraulic system inserted in good
hydraulic tubes were tested as the system pressure holding performance baseline, and
then compared with the pressure decay of the same system when the tube was installed
with connection errors. The experiments were repeated when the system was set up at
different operating pressure levels to test if the system can consistently fulfill its designed
functionality. Through statistical analysis it was found that the developed prototype
system can capture and visualize the pressure decay curve in real time, and two signals,
the pressure drop from the test start to end point and the pressure drop rate in the testing
components’ status.
DEVELOPMENT OF A HYDRAULIC COMPONENT LEAKAGE DETECTING
A Thesis
Submitted
in Partial Fulfillment
Master of Science
Xuanju Shang
December 2015
ii
___________ _____________________________________________________
Date Dr. Zhe Zhang, Chair, Thesis Committee
___________ _____________________________________________________
Date Dr. Nilmani Pramanik, Thesis Committee Member
___________ _____________________________________________________
Date Dr. Nageswara Rao Posinasetti, Thesis Committee Member
___________ _____________________________________________________
Date Dr. Bo Li, Thesis Committee Member
___________ _____________________________________________________
Date Dr. Kavita R. Dhanwada, Dean, Graduate College
iii
AKNOWLEDGEMENT
I want to express my sincere gratitude to people who gave me guidance and help
from the thesis proposal to accomplishment, this study integrated into their wisdom and
time.
To my thesis advisory committee members: Dr. Zhe (Julie) Zhang, Dr. Nilmani
Pramanik, Dr. Nageswara Rao Posinasetti, Dr. Bo Li. Thank you all for giving me the
great instructions, you enlightened me to finish the research from a fuzzy concept to a
logical analysis step by step, and you also encouraged me to do better as I can.
Thanks to Janet Witt and other faculties who supported me to edit the thesis with
To my family, your unlimited love and spiritual support let me have confidence
TABLE OF CONTENTS
PAGE
Background .............................................................................................................4
Assumption ...........................................................................................................10
Limitation ..............................................................................................................11
REFERENCES .................................................................................................................42
LIST OF TABLES
TABLE PAGE
LIST OF FIGURES
FIGURE PAGE
17. Pressure decay curve and equations at 50 psi with leakage condition ..................39
1
CHAPTER I
INTRODUCTION
Based on the definition of Word Net (2012), the hydraulic system is a mechanism
operated by the resistance offered or the pressure transmitted when a liquid is forced
through a small opening or tube (WordNet 3.0, 2012). Through technical integration of
significantly in the past few decades (National Fluid Power Association, 2000). The
changes the functionality, efficiency and accuracy of hydraulic system. As the analysis
“Hydraulics” a key component in the field of applied science and engineering (Global
Industry Analysts Inc., 2013). The wide use of hydraulic systems such as the iron and
steel industry, mining, agriculture machine, defense, automobile, aircraft, ship industry
technology fields.
The characteristics of hydraulic system are the primary reasons why hydraulic
system, equipment and components are widely used in industry. First, the hydraulic
system can transfer high pressure through liquids, and the pressure can reach up to 3000
to 5000 PSI (Pounds per Square Inch), and even more (SKYbrary, 2014). As shown in
Figure 1 (Erjavec, 2004), when the pressure is converted to the force and it can complete
specific work for example used in the crane, digger, and lifting jack to lift workload.
2
Second, power units such as pumps and motors can be connected through
hydraulic tubes, which make the assembly of mechanical components more flexible in a
constrained space. The typical cases are that the steering unit, driver unit and auto rise up
unit can be combined together on the automobile, tractor and spraying machine as shown
in Figure 2 (Rosth, 2007). As a result, the connections through hydraulic tubes lead to a
hydraulic system with a small size, light weights, and changeable working directions for
the mechanical system to conduct workload in flexible means which is another important
The third very important feature is that the hydraulic system can easily implement
control and high degree of automation that means servomechanism or servo. As the
definition by Jyotsnaj in his blog (2009), the servomechanism is an automatic device with
mechanism. The process of sending the error signal back for comparison with the input is
called feedback. The whole process of the input, output, error signal, and feedback is
called a closed loop. The Figure 3 (Jyotsnaj, 2009) shows a typical example of main
is when an airplane uses the automatic hydraulic servomechanism (Fine Tubes Company,
2006) to adjust the angle and areas of wing through computer control system to
Figure 4: A380 hydraulic flying control servo system (Fine Tubes Company, 2006)
Due to the advantages presented above, the hydraulic products have been
extensively used in force conversion, power exchange and other mechanism control
system aspects.
Background
The quality of the hydraulic system design and manufacturing plays a key role in
the entire machinery system. No leakage is one of the critical quality features that will
ensure the hydraulic system quality. Absolute leakage for any hydraulic and pneumatic
valve, cylinder, tube, hydraulic oil, seal parts, control system and related accessories.
Contrary to so many advantages mentioned earlier, there are also some disadvantages.
The hydraulic system has higher requirements for maintenance compared with ordinary
5
mechanical systems, such that the hydraulic oil cleanliness must be maintained at a
certain level; the working environment temperature must be in certain range; and the cost
for components are relatively high. Comparing with common mechanical systems, the
hydraulic system. From the quality engineering aspect, the hydraulic leakage is one of the
80% of machine and equipment stoppages and component failures; many times these
contaminated fluids are a direct cause of fluid leaks from hydraulic machinery (Leugner,
2010). The leakage will cause unnecessary energy consumption, reduce equipment
performance, decrease reliability and increase fluid costs. The direct impact is that the
system loses pressure, which results in insufficient power to do the intended work, and
even sometimes, the hydraulic system leakage can cause vital accidents. Moore (2012)
mentioned an injury that a shop technician who incurs an injection of hydraulic fluid at
the base of his finger when investigating a leak in a wheel loader. After few hours when
this injury occurred, his hand was severely swollen and inflamed, with dark discoloration
in his index and middle fingers. So, effectively and safely detect the leakage status for the
Currently, it is still very common to use hydraulic oils to test if there is a leakage
in the hydraulic system. Because the medium of the hydraulic system is oil when there is
6
a leak, it may cause pollutions and even risks for fire. Particularly, the petroleum-based
hydraulic oils are environmentally more difficult to handle. The cleaning and disposal of
hydraulic oils require special physical and chemical treatment techniques by an EPA-
authorized hazard waste management agency which would incur additional costs to the
manufacturing companies. Sometimes the hydrostatic pressure test can use water as
medium, but in some special conditions when the material and system are sensitive for
corrosion, this method cannot be used. This study will focus on the detection of leakage
for hydraulic systems in using clean air as a testing medium, as a result to filter individual
hydraulic components with leakage flaw in the first place, and also help assure the quality
such as pump, valve, cylinder, tube, seal parts and related connecting accessories. The
leakage reasons could be: bad or damaged threads in the connecting hoses, the product
dimensions are out of tolerance, and/or faulty actions such as wrong mating occurred in
the assembly process. Sometimes the leakage may even be caused when the components
are conforming parts without any quality issue. For example, hydraulic connecting tubes
in good quality could have leakages caused by the contaminations of the connectors or
Developing a prototype system to quickly and easily detect the leakage risk before
the hydraulic component leaving the factory is the main objective of this research.
7
Statement of Purpose
leakage testing system will be developed by using compressed air instead of hydraulic
oil, so that this system can be easily implemented in the manufacturing floor to detect
hydraulic components’ leakage status, meanwhile the pressure change of the testing
hydraulic parts to ensure the manufacturing quality. It is still common to use liquids to
test hydraulic leakage in many applications where the liquids sealed in the hydraulic
circuit must be compressed to a very high pressure level. This may not be an easy, safe
operation for some small manufacturing shops. This research proposes a novel leakage
test method by using compressed air as a test medium at a relatively low pressure range
to assure the quality of hydraulic individual parts and assembled systems with less safety
and environment concerns. The proposed testing system will provide the following
characteristics:
1. Low operation risks and high safety assurances in the operation process compared
to the leakage test system employing high pressure hydraulic oil. The general air
pressure in the test system is about 100 psi while the oil pressure could be up to
3000 psi and runs the risk of causing accidents and hurt operators.
8
hydraulic oil leakage may influence the working environment; and it will also
incur additional costs to clean the pollution if any oil leakage happens in the
testing process. In addition, the oil needs containers and places for storage around
the manufacturing floor. Even when the hydraulic parts are produced with no
leakage problems, disposal and draining of the testing hydraulic oils require
resources.
3. Ensure that the hydraulic products freshly produced will comply with
required to be clean before they are moved forwarded for the assembly process.
With no cleaning process needed, the air based leakage test system could meet the
facility.
4. Low-cost and high efficiency. The cost for the testing medium (air) could be
ignored compared to the hydraulic oil. The proposed leakage test system
integrates computer and real time data acquisition technology. Once the testing
parameters are set up, it doesn’t need people to be around and it can monitor,
record, and visualize the pressure changes automatically. Meanwhile, the pressure
change and the pressure change curve and trend visualization can be calculated
and displayed by a VBA (Visual Basic for Applications). Given the specific
determined.
9
5. The air has much lower density and viscosity than oil, so it is easier for air to
penetrate the tiny gap between the assembled hydraulic components. Therefore
the air testing system renders a tight quality standard. The low viscosities indicate
rate.
Leakage rate is a function of fluid viscosity. As the Formula Book for Hydraulics
and Pneumatics of Linkoping University (2008), the formula of the leakage flow
The formula indicates the relationship of gaps, pressure and viscosity. The leakage
volume will be directly proportion upon the viscosity and pressure change. The gap
height “h” has much more influence on the leakage than the length.
ℓ: length [m]
above analysis, when the viscosity and pressure values of air and oil are used in the
formula respectively, the values of air uses 33 psi and 0.018 centipoises, oil uses 3000 psi
10
and 65 centipoises, the calculated result shows that air can more easily leak at same
temperature and same gap than oil. The theoretical derivation shows if the hydraulic
component can successfully pass the air-based leakage test system, it may pass the
Based on the justifications above, the research proposes to develop an air based
leakage detection system that can be easily adapted by the manufacturing companies that
The research proposes to develop the air based leakage testing system that
After the system coupling hardware and software components were completed through
• If the proposed system can capture the difference of pressure changes for the
• If the proposed system can perform consistently at different air pressure levels?
• If the regular pressure decay pattern for further comparison study could be find
out?
Assumptions
1. The test instruments (sensor, data acquisition board, pressure gauge) are in good
2. The testing samples (tubes) can perform consistently and their tiny variations in
3. The testing air supplied in the production lab is clean and its impurity will not
4. The air pressure supplied in the production lab may have minor variations, but the
air pressure fluctuation will not impact the performance of the developed
5. The testing accessories in the system such as seals and connectors are normal and
Limitation
The objective of the research is to develop a low-cost prototype system that can
display pressure decay in real time through a low-cost USB-based microcontroller so that
it can be easily used in the manufacturing floor. The research bears the following
limitations:
1. The research plans to measure the pressure drop for faulty hydraulic components
against the performance base line of pressure drop for non-faulty hydraulic
leakage or non-leakage. The leakage detection system does not intend to measure
2. This research does not perform the comparison study between hydraulic leakage
tests in using air or oil as testing medium. With more data collection in the future,
3. Because the air pressure is supplied by the production lab air compressor and the
researcher cannot adjust the incoming air pressure level and also because of safety
concerns, the leakage detection test will be only conducted at less than 100 psi
pressure range. Therefore, the testing results to be concluded only will be applied
4. To construct the hydraulic detection system and make the system function
properly, all the components must be connected tightly to make sure the system
does not have leakage. As digital wrench tools that can provide numerical torques
are unavailable to be used in this research, the regular soap bubble leakage test is
1. Review the past literature about the leakage detection such as leakage detection
2. Design and layout the system schematic before purchasing the components.
4. Write and test the data acquisition computer program in using VBA that is
5. Integrate the proposed pneumatic system by interfacing the data acquisition code
with hardware.
6. Conduct test activities including collection and analysis of data, and making
conclusions.
Definition of Terms
1. PSI: means pounds per square inch. It is a unit of pressure or of stress based on
2. The Pascal (Pa): is the SI derived unit of pressure, internal pressure, stress,
Young's modulus and ultimate tensile strength, defined as one newton per square
3. VBA: Visual Basic for Applications (VBA) is a macro language of Basic. It was
task programming language. The main functions can be used to extend the
CHAPTER II
LITERATURE REVIEW
The hydraulic leakage generally includes two kinds of status: the external leakage
The external leakage often happens on the connection and seal position, such as
the connecting position between cylinder and tube, or the valve and tube. Faulty
installation and poor maintenance are the primary causes of external leakage. The
excessive pressures or contamination can cause seals to blow or be damaged. The leakage
could be caused by a gash, rust or other corrosion hole, a very tiny pinhole leak, crack or
micro crack, or inadequate sealing between components or parts joined together. For
example, the seal issue or the tiny pinholes can cause the leakage coming from hydraulic
cylinder and hydraulic rod. External leakage can be hazardous, expensive, and unsightly.
According to the study by Parker Hannifin Corp (2013), three drops of oil leaking per
minute from one place in hydraulic system will lead to 9.3 gallons in a year, which costs
The internal leakage often happens on hydraulic system interior. It can occur in
the pump, valves, and other moving parts such as the leakage between valve spool and
valve housing, leakage between two gears in gear pump, leakage between cylinder rod
and sleeve. Internal leakage almost can’t be avoided and it is more difficult to detect and
isolate. Partial internal leakage can act as a self-lubricate function, but too much internal
leakage will slow down actuators. The power loss is accompanied by the heat generated
at a leakage path. The clearance between two components is the key factor causing
15
internal leakage. It includes the fitting clearance and assembly clearance. The fitting
clearance indicates the manufacturing precision of single parts. The assembly clearance
indicates the process stability of assembly process. The minimum fitting and assembly
clearances are key parameters to ensure the internal leakage. The oil film thickness takes
effect to seal two parts instead of the specific seal components. When the clearance of
two matching parts is bigger than the oil film thickness, the leakage will happen. Based
on the calculation result from “Leakage Calculation through Clearances” (Huang, 1994);
the formula of mass flow rate (𝑚𝑚̇) indicates the relationship between clearance, viscosity
and geometry with fixed pressure ratio. The clearance height “δ” has much more
𝜌𝜌𝛿𝛿 3
𝑚𝑚̇ = 𝐺𝐺 where:
12
G = Geometry
𝜌𝜌 = viscosity
The following gives a brief overview of various leakage detection methods that
The simplest external leakage testing method is through observation. The oil
leakage area has an obvious oil mark. Sometimes, the leakage is not easy to be observed
directly, and the test can be performed by applying a soap solution to potential outer leak
sources and observing for bubbles. This is so-called soap bubble method.
16
The aerostatic pressure test that defined by ASTM 380 - 94 (2012) also belongs to
the bubble test. It puts the test hose with pressured air under the water, and once can
observe if there are bubbles coming out from hose surface in two minutes. If a steady
stream of bubbles out from any location it shall be considered failure to meet the test.
position should be repaired, SAE Sub 4 (1977) provides a leakage classification as listed
in Table 1 to define leakage levels. Table 1 can be used to level leaks based on qualitative
leakage information.
The bubble detection method will be used as the initial checking method to
Table 1
In many complex hydraulic systems, especially for the heavy industry, the high
pressure and large rate of flow circuits system are fit to measure the components
temperature to justify the internal leakage. Such as the steel mill production line, there are
many pumps, valves and cylinders which are served by one hydraulic station, some of
valves or cylinders on the function parts; the internal leakage of them is not fit the
measurement by flow meter. The basic theory of using heat to detect leakage is that the
internal leakage caused the power loss. The flow energy is not transmitted as mechanical
power but transformed to the heat. So the lost power gives raise of the temperature. In the
research conducted by Mollo (2001), the leakage on the high pressure gears pump
increase 1 gpm (gallon per minute), and then the temperature rise would be more than
20 °F at 2250 psi and 80 °F at 4500 psi. The infrared heat gun can be used to measure
temperature. Generally, the heat distribution data of a new hydraulic system is treated
as the base line, and then it is compared with the operational pressure change and
temperature change to justify the internal leakage status. If the temperature change is
larger than a certain cutoff value, it can be concluded that the pump or valve needs to
maintain or repair. This method cannot quantify pressure lost. But it can only estimate the
For the internal leakage, the acoustic emission method has been employed by
high pressure or high speed leaks in different locations of valve and cylinder leakage
18
Acoustic emission was defined as the transient elastic waves generated by the
rapid release of energy from localized sources. It has been found that acoustic emission
signals can be produced by fluid leakage (Nivesrangsan, Steel, & Reuben, 2007). When
turbulent flow conditions existed in the leakage hole in a pressure boundary, the time
dependence of the flow was caused by the instability of the fluid flow. The acoustic
emission Root-Mean-Square (RMS) value was often used to calculate the average energy
1 𝑄𝑄 8 𝑝𝑝 𝑆𝑆 4
1
AE2RMS = C1𝛼𝛼5 𝜌𝜌3 𝐷𝐷14 �𝑐𝑐 � � ∆𝑝𝑝 �
𝑣𝑣
C1: the function of fluid variables with some factors neglected to simplify the
relationship
This equation is the basis for a quantitative approach. The variants of volume flow
rate and the pressure drop across valve are very sensitive to influence the test result. This
19
method is able to fix the position of the leakage and detection of acoustic emission
signals produced by liquid and gas. The leakage through valves can be related directly to
the qualitative leakage rate. The effect of the influenced factors of leakage rates, inlet
pressure levels, valve sizes and valve types are the variants to influence the quantifiable
frame, we need to use a flow meter or other related test equipment needs to be used
(Slater, 2001 ). Detection of unknown internal leakage in most cases would depend on
specific tools to detect the location and leakage volume. Leakage issues or a unstable
hydraulic circuit to perform its designed function need to install flow meters in various
locations to detect excessive leakage; that caused by the components over tolerance
clearances of mating inner surfaces. The installation flow meters on pumps and motors
help to determine when overhaul of these components are needed before performance is
severely affected. For example, when the internal leakage happens, the pump has to
increase flow rate to keep the system maintain a constant pressure. When the flow rate is
out of defined range, it can be deduced that the internal leakage is unacceptable. In
critical hydraulic systems, both the control valves and the hydraulic cylinders need timely
pressure change. According to ASTM A1047M – 05 (2014) testing standard, leakage can
20
time. This method uses one set standard part to be the base line, and against another tube
at an identical pressure or volume, the instruments to measure the pressure at the end of
test period, if the final test pressure has not cross the threshold pressure, it could be
the drop in pressure over time in a specific range could determine if the test is passed or
not.
tubing to a suitable low pressure and measures the increase in pressure. If the pressure
has not crossed the threshold pressure, the test should be passed.
measurement instrument, an operator needs to be around all the time so that the operator
can read the pressure change immediately. If the pressure gauge is not connected in an
automatic data acquisition system, it is hard to record and remember the pressure change.
fast detection and diagnosis of leakage conditions. The Festo (US) system company
developed PLC-based real-time control and data acquisition system. It includes hardware,
software, and human machine interface control panel to make up this mechatronic
21
system. The research was to diagnose the leakage fault of pneumatic system by
comparing the flow rate and pressure change. The leakage classification curve can show
the multiple-actuator pressure change result. It gets feature extraction through the wavelet
transform. Its localized properties are in time and frequency domains. Its fast algorithms
are ready for an on-line implementation. And its efficient data compression is for feature
extraction. Figure 5 (Zhang, 2011) displays the threshold range in details. In coming
cycle, each sampled value will be compared with the three-sigma rang.
The research of Zhang (2011) and the equipment of Festo system company PLC-
based real-time control and data acquisition system have practical and theoretical
meaning, it inspired the proposed research approach to combine the pressure gauge and
22
monitor system together through a microprocessor data acquisition system, so that the
pressure drop due to leakage can be captured and displayed in a computer in real time.
This approach for leak detection is called on-line system monitoring and performance
CHAPTER III
METHODOLOGY
This chapter will describe the methodology of the study, including categories: (1)
pneumatic system schematic and layout, (2) hardware set up, (3) data collection system
development, (4) data analysis software development, (5) data collection, (6) data
analysis.
the study, test and analysis for hydraulic leakage detection. Based on the schematic, the
1. The dry and pressurized air from the production lab is pumped through the filter
to clear the impurities and then is pumped into the testing system.
2. The regulator and flow valve controls the pressure and rate of flow for the test
needs.
3. The first bidirectional valve is used to control the air into to test unit or not, while
the second bidirectional valve is used to control the air release from the test unit.
They all accept the signal from the computer control board.
4. The pressure transducer monitors the pressure change on line, and sends the
changed signal to the data acquisition module. The data will then be recorded and
5. The gauge on line could be the pressure monitor and read directly by the tester.
24
Hardware Setup
1. A regulator that combines with 5 micrometer filter and a 100 psi gauge, it was
2. A flow controller and two bidirectional valves, they were used to control the air in
3. A 200 psi pressure gauge, it can observe the pressure of test unite.
4. A pressure transducer to monitor the pressure change and create the voltage
signal.
9. Two muffles assembled on bidirectional valve to reduce the noisy of air release.
All the test components were mounted on the testing platform that is a sheet metal
Table 2
The basic working theory of the data collection system is: the pressure transducer
detects the pressure change when the test unite has leakage, and the pressure change is
transformed to the voltage change signal and then captured by DAQ Board (USB-
1608G). The DAQ board connected with the computer by a USB port, the voltage signal
was collected and recorded by the software that was developed in using VBA (Visual
Basic Application). The pressure and voltage ratio through the pressure transducer was:
27
1.0 psi equal to 0.03 volts, the related coefficient was defined in the software and directly
reflects on the pressure degradation curve that was created by the software.
automatically control the system operations. The bidirectional valves will take action
through the commands from the VBA software in Excel so it will release the air in and
The data acquisition software was customized and developed. It uses Microsoft
VBA functions in an Excel file to control the electrical –mechanical equipment to realize
the electrical signal collection and test system control function. The data acquisition
1. When starting a new test, it needs to initialize the data to clean out the old
2. The acquire icon can show the real time pressure point.
3. Click the start test icon, the software starts recording the real time pressure.
4. At the end of test, the final pressure and the real time data of pressure changes
will be recorded by the software in a test cycle (50 seconds) on the data sheet
page.
29
5. The pressure change curve will be created and shown on the main interface.
Figure 10 was a pressure change curve under non-leakage status that was obtained
from a pilot test. Figure 11 was a pressure change curve under leakage status.
6. Copy or move the test data to another data sheet for reference and calculation.
Data Collection
The experiment was conducted in two steps. In step one, the system performance
baseline on the pressure drop was established. To do this, the first treatment was the
normal system setting, which was generated by tightly inserting a good thread tube. In
Step two, the system was set up on purpose to have leakage by loosely inserting the
hydraulic tube.
The pressure holding time was set at 50 seconds. A testing time is given in ASTM
1047 / A 1047M – 05 that quantifies the leakage detection time for pressure decay. For a -
inch OD by 0.050 inch wall by 60 feet long tube with a 0.003 inch diameter hole, the
leakage detection time is 1.7 seconds. Therefore the testing period of 50 seconds would
To answer the second research question, the purpose of this step was to check
whether the system can consistently perform the designed function. The pressure decay
was measured 10 times when the hydraulic system inserted in a good tube was set to
different pressure levels less than 100 PSI (82 PSI and 50 PSI respectively);
Two groups of data were acquired at two kinds of artificial conditions. The first
condition was under non-leakage status. The bubble checking method was used to
confirm there was no leakage happening. There were ten sub groups of data recorded
under the pressure 50 psi condition, and every sub group includes 50 pressure values
(recorded in appendix). The same method was used on the second condition under
leakage status, which means the bubble checking method was used to confirm that there
Data Analysis
To identify the pressure decay at the setup pressure levels, the leakage and non-
leakage status were recorded. The statistics analysis software Minitab was used as the
primary tool for data analysis. The pressure change value ∆P of every sub group was
When the system was set at 50 psi, the changed pressure values of every sub
group at non-leakage (∆P1) and leakage (∆P2) status were listed in Table 3.
Table 3
∆P1 0.4610 0.3987 0.3914 0.3781 0.3941 0.1895 0.4285 0.2477 0.3712 0.2811
∆P2 8.4164 8.1931 8.3363 8.4489 8.3798 8.2841 8.3318 8.3130 8.1999 8.2603
32
Based on the statistical analysis, the two samples of T-Test results are as following.
From the above T-Test result, the P-value equals zero so it can be concluded that
the second group of data was statistically different from the first group of data. The
For the object to verify the test system will be able to perform consistently at
different air pressure levels, the higher pressure with the 82 psi test condition was
conducted. The changed pressure values at non-leakage (∆P3) and leakage (∆P4) status
Table 4
∆P3 0.2092 0.1689 0.2129 0.2637 0.2367 0.2719 0.2435 0.1648 0.2065 0.2628
∆P4 2.336 2.2929 2.3016 2.1844 2.2911 2.1423 2.2092 2.0805 2.1524 2.1762
33
The results demonstrated that the data at leakage status was statistically different
from the data at non-leakage status. The leakage status was identified. The system can
To further analyze the trend of system pressure change and conclude the pressure
decay model in testing period, Microsoft Excel software was used as the data analysis
tool.
Firstly, the linear pressure decay curve of every sub group data was created as
shown Figures 12 to 15. The curves can intuitively and clearly reveal the pressure decay
status for every test. When the linear trend lines were added on the selected chart series in
Excel, the specific pressure change equations and the coefficient of time are listed on the
charts. The intercepts and slopes (coefficients) showed that the air pressure of test was
not perfectly consistent; the inconsistency is due to the fact that the initial pressure was
obtained from the shop had a little variations. But all the pressure decay curve trends are
The random selected equation of sub group data of every figure is as following:
The equation of sub group data linear 5 at 50 psi under non-leakage status in
Figure 12 is:
y=-0.0012x + 50.315
The equation of sub group data linear 1 at 50 psi under leakage status in Figure 13
is:
y = -0.1716x + 51.368
The equation of sub group data linear 7 at 80 psi under non-leakage status in
Figure 14 is:
y = -0.001x + 83.123
The equation of sub group data linear 6 at 80 psi under leakage status in Figure 15
is:
y = -0.0456x + 82.99
The equation of linear 5 in Figure 12 indicated the slope for pressure change is
very small accompanied with time change. The slope for pressure change of linear 1 in
12.
The pressure change curves and slopes at 82psi pressure status are as Figure 14
and Figure 15. The slope proportion of leakage lines is 45 times of non-leakage lines.
35
50.8000 Series2
50.6000 Series3
y = -0.0012x + 50.317
50.4000
Series4
50.2000
Pressure (psi)
50.0000 Series5
49.8000 Series6
49.6000
Series7
49.4000
49.2000 Series8
49.0000 Series9
48.8000
Series10
0 10 20 30 40 50 60
Time (s) Linear (Series5)
50.0000 Series3
Series4
48.0000
Pressure (psi)
Series5
46.0000 y = -0.1716x + 51.368
Series6
44.0000 Series7
Series8
42.0000
Series9
40.0000 Series10
0 10 20 30 40 50 60
Linear (Series1)
Time (s)
82.5
Series5
Series6
82
Series7
81.5 Series8
Series9
81 Series10
0 10 20 30 40 50 60
Linear (Series7)
Time (s)
According to the observation of pressure change curves at 50 psi and 82 psi, the
pressure decay curves appear to fit well in a linear line. One linear regression model was
generated out of the four data collection treatments and was marked in Figure 12, 13, 14,
and 15, respectively. To confirm that the experimental data meet the assumptions of
multiple regressions, the normal probability plot of pressure data was created to check
normality and residual plot was created in Figure 16 to make sure that regression models
Residuals
50.5 0.2
50.4
0.1
50.3
50.2 0
0 50 100 150 0 20 40 60
-0.1
Sample percentile Time: second
40 0.1
Residuals
20 0
0 20 40 60
0 -0.1
0 50 100 150
-0.2
Sample Percentile Time: second
(Figure continues)
38
83.1
0
Residuals
83 0 20 40 60
-0.1
82.9
82.8 -0.2
0 50 100 150
-0.3
Sample Percentile Time: second
82.5
Residuals 0
82
81.5 -0.05 0 20 40 60
81 -0.1
80.5 -0.15
0 50 100 150
-0.2
Sample Percentile Time: second
distribution of the pressure data. The residual plots for non-leakage at 50 psi and non-
leakage at 82 psi indicated the residuals were approximately constant magnitude and
randomly spread, which means the linear regression line includes all the explainable
items; the residuals for leakage at 50psi leakage condition, there was an obvious
quadratic pattern, which indicated a second order term should be included in the
regression model; the residuals for leakage at 82 psi are in between of the random pattern
39
and quadratic pattern. So, the polynomial equation and R-Square were generated
regarding the pressure data for leakage status at 50psi in Figure 17 and intended to verify
52.0000 Series2
Series3
50.0000 y = -0.1716x + 51.368
R² = 0.9987 Series4
48.0000 y = 0.0005x2 - 0.1958x + 51.578 Series5
Pressure (psi)
R² = 0.99996 Series6
46.0000
Series7
44.0000 Series8
Series9
42.0000
Series10
40.0000 Linear (Series1)
0 10 20 30 40 50 60
Poly. (Series1)
Time (s)
Figure 17: Pressure decay curve and equations at 50 psi under leakage condition
y = -0.1716x + 51.368
R² = 0.9987
R² = 0.9996
the model explains all the variabilities of the response data are around its mean, so the
model fits the test data almost perfectly. The R-Square value of linear model equals
0.9987 (99.87%); it also indicates that the linear model fits the test data very well.
Meantime, the coefficient for the second term in polynomial model is 0.0005; the value is
very small and only contributes a very little portion to the result, so it could be ignored on
According to above analyses, the linear model can be used as leakage model to
CHAPTER IV
The air based hydraulic leakage detection system was developed by pressure
decay signal acquisition technology in this research. Based on above experiment and
analysis result, the test theory and equipment were verified, the leakage model was
1. The proposed system can capture the difference of pressure changes for the faulty
2. The proposed system can perform consistently at different air pressure levels.
These linear equation analysis methods are very easy to be put into practice in
factory with Excel software by quality control or engineering teams. When the specific
slope value is defined, the benchmark curve of non-leakage is fixed, it can very easily
justify the leakage is happening or not. The proposed system can fulfill its designed
function properly. Although the research does not perform the comparison study between
hydraulic leakage tests in using air or oil as testing medium, but the fundamental pressure
decay equation for further comparison with real hydraulic system has concluded.
For further study, the leakage relationship with mathematic equation could be
formed to correlate with leakage flow rates in pressured air or in hydraulic oil.
42
REFERENCES
ASTM A1047-05 (2014). Standard Test Method for Pneumatic Leak Testing of
Tubing. West Conshohocken, PA: ASTM International.
ASTM D380-94 (2012). Standard Test Method for Rubber Hose. West Conshohocken,
PA: ASTM International.
Erjavec, J. (2004). Automobile breaks: Hydraulic system basic theory. 1st ed.
Independence, KY: Delmar Cengage Learning.
Global Industry Analysts, Inc. (2013) Technology Developments Spur Growth in the
World Hydraulic Components Market. Retrieved from
http://www.prweb.com/releases/hydraulic_components/hydraulic_pumps_market/
prweb10736203.htm
Huang, Y., (1994). Leakage Calculation Through Clearances( Paper 953). International
Compressor Engineering Conference. Retrieved from
http://docs.lib.purdue.edu/icec/953
Mollo, J. (2001). Heat Detection Hydraulic System Healt, Hydraulics and Pneumatics.
p50.
National Fluid Power Association (2000). Needs and Requirements. (Milwaukee, WI).
Retrieved from http://www.NFPA.com
Nivesrangsan, P., Steel, J.A. & Reuben, R.L. (2007). Acoustic emission mapping of
diesel engines for spatially located time series – part II: spatial reconstitution.
Mechanical Systems and Signal Processing, 21 (2), 1084–1102.
Rosth, M. (2007). Hydraulic power steering system design in road vehicles, Mechanical
Engineering Linkoping University SE-581 83 Linkoping, Sweden.
SAE Sub 4 (1977). External Leakage Classifications for Hydraulic Systems SAE J1176.
Warrendale, PA: SAE.
44
Sharif, M. A. & Grosvenor, R.I. (1998). Internal valve leakage detection using an
acoustic emission measurement system. Transactions of the Institute of
Measurement and Control, 20 (5), 233–242.
APPENDIX
TEST DATA
Table 5
1 2 3 4 5 6 7 8 9 10
1 50.5179 50.5115 50.5270 50.5751 50.6282 49.6431 49.4270 49.3094 49.4678 49.4609
2 50.1361 50.1727 50.2441 50.2377 50.2913 49.5250 49.0723 49.1098 49.1954 49.2847
3 50.1489 50.2020 50.1956 50.2606 50.2684 49.5209 49.0654 49.1391 49.1995 49.2485
4 50.1160 50.1805 50.2217 50.2364 50.2954 49.5255 49.0393 49.1011 49.2439 49.2567
5 50.1109 50.1906 50.2052 50.2744 50.2895 49.4943 49.0672 49.1313 49.2133 49.2426
6 50.1457 50.1471 50.2263 50.2734 50.2940 49.5268 49.0457 49.1148 49.1945 49.2412
7 50.1329 50.1910 50.2309 50.2762 50.2730 49.5030 49.0411 49.1441 49.2078 49.2206
8 50.1128 50.1846 50.2327 50.2744 50.3000 49.5245 49.0517 49.1235 49.1666 49.2192
9 50.1636 50.1457 50.2377 50.2158 50.3064 49.5163 49.0517 49.1235 49.2123 49.2810
10 50.1416 50.1741 50.1778 50.2757 50.2831 49.5140 49.0457 49.1148 49.2041 49.2188
11 50.1352 50.1833 50.2341 50.2405 50.2872 49.5355 49.0860 49.1277 49.1386 49.2101
12 50.1054 50.1572 50.2158 50.2679 50.3059 49.5030 49.0164 49.1336 49.2201 49.2490
13 50.1366 50.1476 50.2249 50.2451 50.2776 49.4934 49.0425 49.1281 49.1995 49.2741
14 50.1155 50.1590 50.2249 50.2547 50.2716 49.4902 49.0274 49.1386 49.1794 49.2728
15 50.1205 50.1471 50.2034 50.2483 50.3064 49.4916 49.0407 49.0974 49.1794 49.2371
16 50.1324 50.1750 50.2016 50.2377 50.3082 49.4820 49.0901 49.1222 49.2041 49.2741
17 50.1100 50.1576 50.1938 50.2158 50.2831 49.5131 49.0453 49.1231 49.1872 49.2339
18 50.1270 50.1453 50.2277 50.2304 50.2629 49.4778 49.0549 49.1418 49.1844 49.2517
19 50.1210 50.1659 50.2048 50.2428 50.2748 49.4843 49.0082 49.0924 49.1982 49.2760
20 50.1247 50.1498 50.2126 50.2066 50.3169 49.5094 49.0443 49.1048 49.1327 49.2558
21 50.1073 50.1453 50.2350 50.2579 50.2606 49.4820 49.0375 49.0837 49.1615 49.2192
22 50.1187 50.1636 50.2116 50.2267 50.2492 49.4948 48.9986 49.0883 49.1766 49.2210
23 50.1242 50.1361 50.1828 50.2148 50.3032 49.4897 49.0105 49.1208 49.1908 49.2393
24 50.0711 50.1471 50.2061 50.2304 50.2542 49.5012 49.0508 49.0965 49.1922 49.2645
25 50.1096 50.1654 50.1883 50.2510 50.2872 49.5090 49.0201 49.0979 49.1908 49.2270
26 50.1013 50.1471 50.1855 50.2364 50.2657 49.5149 49.0480 49.1336 49.1739 49.2201
27 50.0743 50.1439 50.2112 50.2396 50.2341 49.4971 49.0027 49.1139 49.1602 49.2412
28 50.1439 50.1627 50.1961 50.2597 50.2643 49.5007 49.0356 49.1341 49.1895 49.2526
29 50.0967 50.1476 50.1933 50.2556 50.2908 49.4801 49.0530 49.1231 49.1524 49.2215
30 50.1416 50.1421 50.1823 50.2126 50.2831 49.4783 49.0590 49.0617 49.1803 49.2380
31 50.1260 50.1343 50.1357 50.2423 50.2634 49.4733 49.0512 49.0942 49.1730 49.2535
32 50.0569 50.1242 50.2107 50.2405 50.2638 49.4682 49.0219 49.1020 49.1464 49.2540
33 50.1384 50.1718 50.2094 50.2304 50.2620 49.4902 49.0485 49.0691 49.2009 49.2119
34 50.1036 50.1512 50.1617 50.2240 50.2794 49.5094 49.0283 49.0961 49.1858 49.2494
35 50.1054 50.1471 50.1869 50.1984 50.2931 49.4838 49.0668 49.0906 49.1533 49.2087
36 50.1434 50.1535 50.2071 50.2441 50.2853 49.5085 49.0279 49.1071 49.1830 49.2293
37 50.0958 50.1503 50.1961 50.2084 50.2954 49.4939 49.0100 49.0965 49.1579 49.2197
38 50.1128 50.1292 50.1791 50.2299 50.2817 49.5062 49.0384 49.1002 49.1730 49.2288
39 50.0922 50.1210 50.1768 50.2469 50.2588 49.4847 49.0540 49.0700 49.1753 49.2444
40 50.0803 50.1590 50.1796 50.2286 50.2950 49.4856 49.0462 49.0965 49.1551 49.2256
41 50.1100 50.1338 50.1837 50.2290 50.2748 49.4957 49.0178 49.1011 49.1698 49.2165
42 50.0766 50.1714 50.1993 50.2048 50.2798 49.4563 49.0508 49.0681 49.1505 49.2737
43 50.0935 50.1375 50.1892 50.2126 50.2858 49.4618 49.0704 49.0860 49.1510 49.2412
44 50.1031 50.1160 50.2048 50.1970 50.3114 49.4591 49.0324 49.0915 49.1290 49.2220
45 50.0954 50.1736 50.1736 50.2702 50.2693 49.4646 49.0109 49.1418 49.0965 49.2513
46 50.0780 50.1132 50.2098 50.2281 50.2675 49.4710 49.0146 49.1103 49.1840 49.1798
47 50.0858 50.1672 50.1787 50.2043 50.2615 49.4984 49.0022 49.0897 49.1936 49.2055
48 50.0981 50.1338 50.2061 50.2121 50.2602 49.4701 48.9995 49.0828 49.1670 49.2128
49 50.0803 50.1128 50.1677 50.2213 50.2840 49.4536 49.0224 49.1263 49.1620 49.2151
50 50.0739 50.1517 50.1686 50.2277 50.2428 49.4952 49.0091 49.0938 49.1739 49.2155
46
Table 6
1 2 3 4 5 6 7 8 9 10
1 51.3721 49.7063 49.9068 50.0249 50.0125 49.9196 50.0418 50.0656 49.9718 50.0258
2 51.1903 49.2691 49.3387 49.3813 49.4055 49.4403 49.4801 49.5282 49.5891 49.5959
3 50.9871 49.1176 49.1629 49.1812 49.2513 49.2741 49.2847 49.3675 49.3991 49.4485
4 50.8095 48.9445 49.0054 49.0421 49.0544 49.1002 49.1341 49.1556 49.2293 49.2549
5 50.6287 48.7610 48.7445 48.8452 48.8516 48.8919 48.9565 48.9903 49.0320 49.0828
6 50.4117 48.5568 48.6072 48.6562 48.7184 48.7386 48.7711 48.8022 48.8521 48.8782
7 50.2409 48.3737 48.4355 48.5088 48.5138 48.5646 48.6026 48.6415 48.6607 48.6951
8 50.0583 48.1906 48.2309 48.2588 48.3307 48.3673 48.3888 48.4369 48.4630 48.4904
9 49.8523 47.9947 48.0560 48.1256 48.1659 48.1851 48.2231 48.2753 48.2863 48.3293
10 49.6490 47.8262 47.8912 47.9539 47.9851 48.0043 48.0542 48.1233 48.1627 48.1563
11 49.4810 47.6353 47.7127 47.7869 47.7896 47.8377 47.8656 47.8958 47.9352 47.9590
12 49.3117 47.4797 47.5584 47.5781 47.6422 47.6358 47.7159 47.7187 47.7667 47.8244
13 49.1039 47.2902 47.4129 47.3996 47.4408 47.4948 47.4916 47.5713 47.6152 47.6102
14 48.9345 47.1272 47.1877 47.2742 47.2540 47.2934 47.3167 47.4138 47.4234 47.4646
15 48.7569 46.9331 47.0274 47.0554 47.0677 47.1405 47.1378 47.2224 47.2559 47.2701
16 48.5600 46.7871 46.8700 46.9029 46.9757 46.9473 46.9849 47.0425 47.1053 47.1286
17 48.3820 46.6379 46.6640 46.7290 46.7693 46.8343 46.8237 46.8951 46.9107 46.9221
18 48.2144 46.4447 46.5028 46.5463 46.5898 46.6631 46.6699 46.7001 46.7798 46.7766
19 48.0093 46.2804 46.3316 46.3934 46.4301 46.4438 46.5079 46.5225 46.5720 46.6026
20 47.8400 46.1119 46.1668 46.2410 46.2415 46.2936 46.2996 46.3788 46.3820 46.4337
21 47.6646 45.9375 46.0103 46.0428 46.0670 46.1536 46.1755 46.1961 46.2099 46.2808
22 47.4825 45.7860 45.8546 45.9050 45.9242 45.9837 45.9796 46.0057 46.0469 46.1064
23 47.3071 45.6335 45.6624 45.6844 45.7498 45.7828 45.8620 45.8601 45.9192 45.9210
24 47.1469 45.4422 45.5154 45.5722 45.5901 45.6203 45.6720 45.6610 45.7320 45.7896
25 46.9949 45.2911 45.3378 45.3809 45.4124 45.4381 45.4852 45.5370 45.5548 45.6313
26 46.8118 45.1561 45.1881 45.2380 45.2655 45.3232 45.3246 45.3868 45.4257 45.4491
27 46.6631 44.9886 45.0439 45.0870 45.1044 45.1437 45.1698 45.2060 45.2440 45.2747
28 46.4653 44.8398 44.8842 44.8874 44.9084 45.0037 44.9876 45.0792 45.0549 45.1053
29 46.3033 44.6169 44.7185 44.7391 44.7670 44.8027 44.8398 44.8828 44.9428 44.9854
30 46.1380 44.4992 44.5674 44.5747 44.6040 44.6320 44.7070 44.7382 44.7835 44.7926
31 45.9933 44.3060 44.4333 44.4328 44.4644 44.4960 44.5464 44.5738 44.6475 44.6530
32 45.7759 44.1536 44.2332 44.2763 44.2969 44.3536 44.3710 44.4196 44.4484 44.4919
33 45.6262 44.0076 44.0712 44.1142 44.1536 44.1925 44.2213 44.2676 44.2923 44.3248
34 45.4669 43.8922 43.9462 43.9444 43.9769 44.0268 44.0598 44.1174 44.1628 44.1669
35 45.2870 43.7009 43.7924 43.8144 43.8167 43.8753 43.8744 43.9673 43.9590 44.0163
36 45.1552 43.5612 43.6176 43.6299 43.7100 43.6967 43.7581 43.7549 43.8611 43.9297
37 44.9478 43.3887 43.4811 43.4912 43.5471 43.5553 43.6075 43.6102 43.6986 43.7260
38 44.8535 43.2211 43.3200 43.3539 43.3653 43.3818 43.4317 43.5118 43.5095 43.5773
39 44.7011 43.0984 43.1424 43.2147 43.2280 43.2541 43.3237 43.3438 43.3919 43.4198
40 44.5166 42.9533 42.9945 43.0449 43.1090 43.1158 43.1868 43.1561 43.2211 43.2838
41 44.3655 42.7647 42.8682 42.9291 42.9327 42.9959 43.0220 43.0673 43.0939 43.1039
42 44.1682 42.6443 42.7048 42.7487 42.7876 42.7991 42.8613 42.9080 42.9089 42.9767
43 44.0378 42.5084 42.5597 42.6260 42.6476 42.6727 42.7396 42.7263 42.7583 42.8334
44 43.8606 42.3834 42.4306 42.4457 42.4883 42.5020 42.5812 42.6260 42.6224 42.6750
45 43.7357 42.2383 42.2914 42.3253 42.3555 42.3701 42.4223 42.4493 42.4704 42.4965
46 43.5805 42.0758 42.1188 42.1431 42.2003 42.1994 42.2768 42.3102 42.3523 42.3807
47 43.4253 41.9316 41.9884 42.0589 42.0648 42.0703 42.1449 42.1495 42.1875 42.2530
48 43.2779 41.7659 41.8730 41.8881 41.9339 41.9371 42.0003 42.0433 42.0795 42.0735
49 43.1255 41.6336 41.7151 41.7238 41.7384 41.7833 41.8117 41.8616 41.9078 41.9669
50 42.9556 41.5132 41.5704 41.5759 41.6327 41.6354 41.7101 41.7526 41.7719 41.7654
47
Table 7
1 2 3 4 5 6 7 8 9 10
1 82.2592 82.4666 82.3773 82.5046 82.6501 82.8154 82.9079 82.2079 81.2778 81.4261
2 82.3636 82.56 82.5829 82.7142 82.8799 83.0521 83.1326 82.3247 81.4659 81.6422
3 82.3274 82.4977 82.5774 82.7682 82.8383 82.9811 83.1514 82.3398 81.4842 81.6096
4 82.3114 82.565 82.5902 82.7321 82.8868 82.9944 83.1129 82.332 81.4659 81.6188
5 82.3462 82.5687 82.5357 82.6785 82.8227 83.0484 83.1262 82.3508 81.4778 81.6637
6 82.3105 82.5549 82.5673 82.7641 82.8259 83.0873 83.1313 82.2917 81.4691 81.644
7 82.2958 82.5256 82.5229 82.6822 82.8351 83.0164 83.1354 82.3146 81.3945 81.6531
8 82.2839 82.4963 82.5284 82.6932 82.8268 83.0516 83.1473 82.3489 81.4513 81.6348
9 82.3325 82.5476 82.5046 82.663 82.8671 83.0424 83.1166 82.3393 81.4101 81.6087
10 82.2716 82.5357 82.4492 82.7536 82.8328 82.9752 83.134 82.3105 81.4384 81.6467
11 82.3068 82.533 82.5005 82.7646 82.8273 83.0342 83.139 82.3352 81.4742 81.6266
12 82.2835 82.5215 82.5581 82.706 82.8186 83.0003 83.1454 82.3558 81.4371 81.5932
13 82.3174 82.5398 82.4808 82.7655 82.8429 83.0099 83.0978 82.3055 81.422 81.6888
14 82.2784 82.5096 82.4579 82.6588 82.8191 82.9468 83.1125 82.3663 81.4394 81.6151
15 82.305 82.5165 82.5197 82.7032 82.83 83.0594 83.1377 82.2949 81.4233 81.6252
16 82.229 82.5201 82.4808 82.6263 82.8662 82.9692 83.139 82.3347 81.427 81.5652
17 82.2235 82.4373 82.5371 82.6968 82.8406 83.0081 83.107 82.2638 81.4407 81.6211
18 82.283 82.5201 82.4501 82.635 82.8511 82.9921 83.123 82.3151 81.4183 81.5753
19 82.283 82.5014 82.4922 82.6895 82.831 83.0553 83.0562 82.343 81.4723 81.6087
20 82.2391 82.4684 82.4954 82.6859 82.8172 82.9784 83.1239 82.2661 81.427 81.6495
21 82.2459 82.4483 82.5385 82.663 82.8392 82.9385 83.1015 82.2926 81.4243 81.6147
22 82.2244 82.4629 82.4345 82.6122 82.8264 83.0003 83.1221 82.2849 81.3831 81.6321
23 82.2556 82.4565 82.5536 82.717 82.7866 83.0095 83.0722 82.326 81.4618 81.6385
24 82.2002 82.5357 82.494 82.6813 82.7934 82.9596 83.1322 82.2748 81.4348 81.6115
25 82.2652 82.4872 82.5586 82.6355 82.8049 82.9449 83.0965 82.2679 81.4037 81.5753
26 82.2569 82.3997 82.4881 82.6341 82.7637 82.9825 83.1175 82.3219 81.3647 81.5836
27 82.2569 82.4707 82.4725 82.6653 82.8214 82.9779 83.0818 82.3022 81.4325 81.6019
28 82.2263 82.4702 82.4771 82.6968 82.8777 83.0392 83.0695 82.3059 81.443 81.5845
29 82.218 82.4313 82.5293 82.6685 82.8415 82.9678 83.118 82.2894 81.4032 81.6673
30 82.234 82.4776 82.4748 82.6872 82.8241 82.9486 83.0878 82.2446 81.3556 81.5753
31 82.2194 82.4785 82.4419 82.6891 82.8113 82.9752 83.1175 82.2798 81.3821 81.611
32 82.2176 82.5114 82.4565 82.6437 82.7847 82.9468 83.1079 82.3009 81.4059 81.5776
33 82.2752 82.4886 82.4057 82.6785 82.7357 82.9555 83.075 82.2821 81.3968 81.5936
34 82.2606 82.4625 82.4808 82.6868 82.8017 83.0063 83.0223 82.2885 81.4316 81.6019
35 82.2409 82.4785 82.5568 82.6506 82.7765 82.9472 83.123 82.2935 81.4325 81.5785
36 82.2386 82.4396 82.478 82.6936 82.7756 82.971 83.129 82.3215 81.367 81.5822
37 82.1773 82.4821 82.4496 82.6598 82.8026 82.9326 83.1152 82.3434 81.3913 81.6023
38 82.2185 82.4579 82.5064 82.6831 82.7847 82.9633 83.0658 82.2015 81.3968 81.5538
39 82.1722 82.4991 82.4529 82.6501 82.798 82.9285 83.1212 82.2771 81.4169 81.6156
40 82.1544 82.5027 82.4817 82.6886 82.8081 82.9756 83.0722 82.2583 81.33 81.6151
41 82.2313 82.4043 82.451 82.597 82.7751 82.912 83.0228 82.2537 81.3153 81.5776
42 82.2139 82.4377 82.4583 82.6703 82.7888 82.9189 83.0859 82.2844 81.3721 81.5817
43 82.2812 82.4199 82.4615 82.6598 82.8044 82.9358 83.0466 82.3068 81.3528 81.5945
44 82.2139 82.4373 82.4611 82.6479 82.7335 82.9449 83.0859 82.2437 81.3602 81.524
45 82.1786 82.4451 82.4771 82.6144 82.803 82.9454 83.0818 82.2963 81.3249 81.5968
46 82.2491 82.4657 82.5 82.6483 82.749 82.9019 83.0782 82.2491 81.329 81.5941
47 82.2423 82.4286 82.4391 82.6108 82.7797 82.9285 83.0525 82.3402 81.3739 81.6074
48 82.1823 82.4419 82.4817 82.6442 82.8127 82.9257 83.0873 82.2162 81.4114 81.5657
49 82.1887 82.4396 82.4744 82.6071 82.7179 82.9207 83.0676 82.2359 81.3629 81.5845
50 82.2025 82.4213 82.4474 82.619 82.8099 82.9514 83.0525 82.343 81.4206 81.5941
48
Table 8
1 2 3 4 5 6 7 8 9 10
1 82.03537 82.09076 82.17865 82.42905 82.64557 82.79526 82.25922 81.47095 81.30936 81.47964
2 82.08527 82.19009 82.34894 82.58102 82.72202 82.90009 82.37961 81.58493 81.42792 81.64902
3 82.05276 82.21893 82.37 82.58423 82.75452 82.90192 82.35672 81.53595 81.30295 81.66504
4 81.99875 82.18185 82.26379 82.53067 82.64923 82.86255 82.29309 81.48285 81.31943 81.51947
5 81.9928 82.11594 82.25418 82.55814 82.59705 82.81036 82.18872 81.46317 81.25168 81.54694
6 81.8866 82.07886 82.13791 82.39105 82.52014 82.72385 82.14294 81.43295 81.22192 81.50024
7 81.87561 81.88889 82.06787 82.39059 82.49634 82.70279 82.11685 81.4357 81.1647 81.44302
8 81.7923 81.91635 82.05872 82.31873 82.4675 82.6767 82.08893 81.28372 81.16928 81.41968
9 81.68152 81.83487 82.02255 82.24594 82.43774 82.58011 82.07382 81.31668 81.09192 81.28693
10 81.65314 81.89758 81.99417 82.22351 82.3645 82.53342 81.93512 81.28281 81.08597 81.27319
11 81.59729 81.7749 81.91132 82.16537 82.33246 82.49588 81.9548 81.2265 80.96832 81.25488
12 81.58173 81.71814 81.88431 82.12692 82.28577 82.45331 81.93649 81.16882 80.94177 81.23245
13 81.56067 81.71814 81.80649 82.05414 82.22992 82.36908 81.85272 81.12946 80.89279 81.0672
14 81.53137 81.67648 81.78131 82.06238 82.13928 82.37961 81.81335 81.08185 80.91568 81.1171
15 81.43799 81.54785 81.69067 82.01614 82.14981 82.29675 81.76071 80.99121 80.79117 81.05438
16 81.42654 81.53687 81.7598 81.9342 82.07062 82.27203 81.72913 80.99167 80.81406 81.03882
17 81.37436 81.51352 81.63254 81.93512 82.06238 82.22855 81.66229 80.8548 80.68405 81.02371
18 81.28738 81.4476 81.57898 81.80099 81.97952 82.17911 81.61377 80.9317 80.70923 80.923
19 81.26129 81.41235 81.5863 81.79138 81.88568 82.12692 81.5506 80.78247 80.64514 80.96283
20 81.13495 81.36154 81.47003 81.70898 81.87927 82.06329 81.53183 80.74814 80.6369 80.83969
21 81.10107 81.27045 81.38123 81.67465 81.7836 82.04727 81.43616 80.72205 80.54718 80.77606
22 81.0672 81.30615 81.43661 81.63895 81.77216 81.95755 81.38992 80.67398 80.51193 80.77057
23 81.01181 81.24115 81.34048 81.60599 81.75064 81.94016 81.35284 80.69092 80.5188 80.73486
24 80.99762 81.16562 81.21323 81.59546 81.70624 81.83624 81.33087 80.64651 80.43182 80.70053
25 80.91339 81.15051 81.26495 81.49521 81.67191 81.83762 81.32401 80.56686 80.37048 80.67719
26 80.91614 81.07224 81.26907 81.46042 81.62796 81.76483 81.24619 80.52704 80.32242 80.60257
27 80.84885 80.97794 81.18164 81.42288 81.5538 81.76163 81.18073 80.4657 80.29037 80.59067
28 80.78339 80.98526 81.14639 81.39679 81.56479 81.73874 81.09879 80.42999 80.20935 80.53024
29 80.7756 80.97336 81.07224 81.26358 81.49979 81.64719 81.08597 80.36041 80.19058 80.46661
30 80.72937 80.89142 81.04568 81.27411 81.41327 81.64032 81.07361 80.3334 80.12558 80.40115
31 80.68634 80.85571 80.9642 81.22559 81.35651 81.55655 80.97977 80.22583 80.09949 80.29999
32 80.56549 80.75134 80.93674 81.14319 81.30615 81.51581 80.96741 80.24551 80.06699 80.31097
33 80.63416 80.67535 80.86304 81.17294 81.28098 81.48743 80.97473 80.20981 80.08072 80.20157
34 80.54169 80.6868 80.85022 81.10062 81.26495 81.4682 80.86166 80.11276 79.97131 80.20752
35 80.49774 80.67398 80.78064 81.04111 81.16013 81.37115 80.78613 80.13336 79.96124 80.15076
36 80.38971 80.56183 80.72067 80.9166 81.1441 81.34094 80.79254 80.0592 79.94247 80.10452
37 80.35309 80.48538 80.64102 80.93124 81.11389 81.29471 80.74997 80.00427 79.83765 80.07797
38 80.28534 80.52246 80.65338 80.90286 81.07132 81.28006 80.69092 79.9942 79.785 80.00748
39 80.26428 80.43228 80.58929 80.85297 81.02829 81.21323 80.62408 79.96582 79.74106 79.99374
40 80.28854 80.41534 80.51697 80.82367 80.97015 81.1647 80.60989 79.9205 79.67239 80.00656
41 80.15076 80.38742 80.55038 80.76508 80.9198 81.06766 80.59662 79.86511 79.65637 79.91684
42 80.16266 80.3302 80.44144 80.70923 80.8667 81.05347 80.52475 79.76807 79.61517 79.82529
43 80.13519 80.27069 80.43457 80.66666 80.80078 81.04889 80.46616 79.76349 79.60373 79.79691
44 80.03448 80.21576 80.354 80.55496 80.78979 80.96191 80.39886 79.67972 79.52545 79.79462
45 79.99786 80.21622 80.27664 80.55038 80.74356 80.9317 80.36728 79.63852 79.51721 79.73511
46 79.91776 80.09491 80.25284 80.51834 80.71564 80.93307 80.33386 79.5845 79.51218 79.66873
47 79.88068 80.12833 80.25238 80.48584 80.59982 80.86761 80.25604 79.59 79.36569 79.68201
48 79.86923 80.04639 80.17822 80.41946 80.59845 80.78476 80.21118 79.54788 79.34647 79.57581
49 79.7818 79.97498 80.19699 80.44785 80.59204 80.80444 80.17044 79.53415 79.33731 79.5813