Footing and Column Detail

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

11 No's 2 No's

1½" Covering 20mm Ø - 2 No's 1½" Covering 16mm Ø - 2 No's

16mm Ø - 6 No's 16mm Ø - 6 No's

20mm Ø - 2 No's 16mm Ø - 2 No's

Ring: 8mmØ - 6"C/C Ring: 8mmØ - 7"C/C


Column Size: 9" x 18" Column Size: 9" x 15"

21" 21"

15" 20mm Metal 15" 20mm Metal


9" 40mm Metal 9" 40mm Metal
6" Sand Filling 6" Sand Filling

5'-0" 4'-6"

Column No : C1 Column No : C2

16mm Ø - 6" C/C 16mm Ø - 6" C/C


BOTTOM BOTTOM

12mm Ø - 6" C/C 12mm Ø - 6" C/C


6'-0"

6'-0"

TOP TOP

5'-0" 4'-6"

F1 F2 All dimensions are in feets


Drawing not to scale

NO DESCRIPTION DATE

0 NEW DRAWING GENERATED 17-01-2024

GENERAL NOTES:-

1- READ ALL STRUCTURAL DRAWINGS IN CONJUNCTION WITH SLABS/STAIRCASES: 20" TO MAIN REINF.
ARCHITECTURAL & SERVICES DRAWINGS. BEAMS: 40" TO STIRRUPS AT TOP & BOTTOM
2- ALL FOUNDATION SHALL REST ON FIRM AND VIRGIN SOIL.
COLUMNS: 40" TO LINKS
POCKETS OF LOOSE SOIL IF ENCOUNTERED SHALL BE
REMOVED AND REPLACED WITH SUITABLE SOIL.
10- UNLESS SPECIFIED ALL LAP LENGTHS SHALL BE MINIMUM OF
3- ALL STRUCTURE CONCRETE IN FOUNDATION, COLUMN 48 TIMES DIA OF BAR EXCEPT COLUMN PREFERABLE LOCATION
UNDER GROUND WATER TANKS SHALL BE WITH MINIMUM TOP BARS SHALL BE AT CENTER OF SPAN AND FOR
CYLENDRICAL STRENGTH OF 4000psi AT 28 DAYS BOTTOM BARS SHALL BE AT SUPPORT.
STRUCTURE
4- ALL CONCRETE OTHER THAN MENTIONED ABOVE IN NOTE 3 SHALL
BE WITH MIN. 28 DAYS CYLENDRICAL STRENGTH STRENGTH DETAILING OF PILES AND
OF 3000 psi. THE LAP LENGTH SHALL BE CALCULATED ON THE BASIS OF
DIA OF SMALLER BAR. FOOTING
5- FOUNDATION DESIGN IS BASED ON SAFE ALLOWABLE
BEARING CAPACITY OF 0.75 TSF. CONSULTANT
11- ALL EXPOSED SURFACE OF CONCRETE ON EARTH SIDE SHALL
6- SULPHATE RESISTANT CEMENT SHALL BE USED IN ALL BE PROTECTED WITH TWO COATS OF BITUMINOUS PAINT.
CONCRETE WORKS UPTO PLINTH.
12- ABBREVIATION USED ARE
7- ALL REINFORCING BARS SPECIFIED BY .NO.(#) SHALL BE
COLD WORKED RIBBED TOR STEEL OR DEFORMED BARS T : TOP
STHAPATHI
WITH MIN. YEILD STRENGTH OF 60,000 PSI. B : BOTTOM ARCHITECTS & CONSULTANTS
EF : EACH FACE # 5-381, 1ST FLOOR, RAAVI ANJANEYULU STREET
8- ALL REINFORCING BARS SPECIFIED BY DIAMETER (Ø) SHALL NSE : NOT SHOWN IN ELEVATION OPP:POWER OFFICE,KURNOOL ROAD,ONGOLE -523001
BE PLAIN MILD STEEL WITH MIN. YEILD STRENGTH NSP : NOT SHOWN IN PLAN E Mail : [email protected] Ph No: 9866938926,9502478008
OF 36,000 PSI.
BL : BOTTOM LEVEL OF FOUNDATION
9- UNLESS OTHERWISE MENTIONED IN DRAWINGS ALL CLEAR
CONCRETE COVER SHALL BE AS FOLLOW.

PROJECT NUMBER DETAILING-01

DATE

FOOTING & COLUMN DETAIL DESIGNED BY

CHECKED BY

S-2
A.VEERA BRAHMAM

M.SAI KUMAR