0% found this document useful (0 votes)
152 views4 pages

Fanuc Controller Fanuc Controller Software

This document provides information on Fanuc controller parameters related to starting the Manual Guide I (MGI) software and customizing the controller display. It notes that the machine in question did not test the MGI function before shipping. It then lists several parameters, their default values on other controllers, and comments explaining how modifying the parameters can enable MGI, control the display screen, and customize other controller functions.

Uploaded by

wega7777
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
152 views4 pages

Fanuc Controller Fanuc Controller Software

This document provides information on Fanuc controller parameters related to starting the Manual Guide I (MGI) software and customizing the controller display. It notes that the machine in question did not test the MGI function before shipping. It then lists several parameters, their default values on other controllers, and comments explaining how modifying the parameters can enable MGI, control the display screen, and customize other controller functions.

Uploaded by

wega7777
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Page 1 of 4

Fanuc Controller
Fanuc Controller>>Software

MGI can't start

EX:MV-50I#0112 SET LBV-3224 MGI PARAMETER SHOW:


1.Log in Manual Guide I will show the alarm message.
Parameter revise P27000=00000000 -> 01000000
P27004=00000000 -> 00000001

2.Push blank button MGI screen not show


Parameter revise P14794=00100000 -> 00000000
P14795=00000000 -> 00101000

This machine not test MGI function before shipping.

LBV-3224 21I-MB Manual Guide I Parameter Compare


Parameter LBV 21I- Vertical-milling Statement
No. MB
P3103 00000000 00001000 #2: When two-path control is applied, the
current position display screen displays: The
current position of a path selected by the
tool post select signal.
#3 : In the FS160i and NC systems
connected to a personal computer
(with an Ethernet board or HSSB
board), NC software reads the
[HELP] key and changes screens

http://www.leadwell.com.tw/faq.php?mode=show&serialNum=78&faqSerialNum= 2009/3/13
Page 2 of 4

even when a C-EXE screen is


being displayed.
To suppress this, set bit 3 of parameter No.
3103 to 1. The NC software will then ignore
any press of the [HELP] key while a C-EXE
screen is being displayed.
P3106 00110010 00000100 #3: During multi-spindle control, names for
actual spindle speed values are displayed:
Depending of the selected spindle position
coder (in second position coder selection
signal (PC2SLC))
#4: The operation history screen is:
Displayed.
#6 : The function of C language
executor refers to this parameter. If
this parameter is set to 1, Slant
face machining does not work
correctly.
P3112 00001000 00101100 #0=0 : This parameter enables or
disables servo waveform display.
When this parameter is set to 1,
other graphic functions become
unavailable.
P3116 00000101 00000100 #2 : Alarm No.100 (parameter enable) clear
by reset key
P3201 01000000 01000000 #6 : With an M02, M30, or M99
block, program registration is
assumed to be not completed
P3206 01000000 01000000 #6 : Absolute position display in the three-
dimensional coordinate conversion mode
using BOP follows the setting of bit 6 (DAK)
of parameter No. 3106
P8650 00000011 00000011 #0 : When the reset key is pressed,
the key code is passed to the
OVERHAUL
application using C language
OF
executor.
PROCESS
When an NC alarm is issued
during the display of the user
screen for the C language
executor: The NC alarm screen is
not displayed
#1 : During display of the screen of
C language executor, Alarm screen
is not changed when the alarm
occurs.

P8652 00000000 00010000 #4: When the [FAPT] key is pressed, the C
language executor screen defined with
CRT_FAPT is: Displayed.
P8661 40 40 Variable area size(0~59)
P8662 23 23 SRAM disk size(4~63)
P8701 01010000 01010000 #4 : Read of “vacant” P code macro
variables is enabled.
#6 : When the TV check is set to ON, edit
operations are not regarded as errors
P8781 0 0 Amount of DRAM used with the C language
executor (16~64)
P9000 00000000 00000000 #0=0 : This parameter is for debugging
machining macro program. And if this
parameter is set to 1, Manual Guide I does
not work correctly.
#7=0: If this bit is set, MANUAL GUIDE i
does not update the screen display at the
time of operation, and cycle execution is not
performed normally.
P12381 10000 10000 Top number of variables for measurement
condition
P12382 10180 10180 Top number of variables for calibration
P12383 10300 10300 Top number of variables for measurement
execution

http://www.leadwell.com.tw/faq.php?mode=show&serialNum=78&faqSerialNum= 2009/3/13
Page 3 of 4

P12384 10500 10500 Top number of variables for storing


measurement result
P12385 699 699 Amount number of variables for storing
measurement result
P12386 951 951 Address of PMC R signal for measurement
P12387 0 0 Macro program number for tool select
P12388 3600 3600 Macro program number for measurement
execution
P14700 00000000 00000000 #0=0 :When the power is turned on, the
system is not switched to the Manual Guide
screen.
#2#3=0: When the power is turned
on, the custom screen is not
displayed
#7=0 : MANUAL GUIDE i is enabled.

P14702 00000000 00000000 #0=0 : Vertical.


#0=1 : Horizontal
#1=0 : No sub-spindle is provided.
P14706 20 20 Number of Workpiece coordinate
for main spindle
16 : Right-handed coordinate system, right
= +Z, up = +X
20 : Right-handed coordinate system, right
= +X, up = +Z

P14713 55 255 Scaling unit for graphic


enlargement and reduction.
Scaling unit = 64/GRPSCALE
P14714 10 10 Graphic horizontal movement unit (dots)
P14715 10 10 Graphic vertical movement unit (dots)
P14717 4 0 Rotate (Cs) axis number
P14718 5 0 Rotate (Cs) axis number, which tilts tool
head or table
P14794 00100000 00000000 #0~#5=0 :
The Manual Guide does not start when
function key 1~6
P14795 00000000 00101000 #3=1:
The Manual Guide starts when
function key < > is pressed.
#4=0,#5=1,#6=0:
The maximum memory size is set to 1M
byte.
P27000 00000000 01000000 #0=0 : In ZC plane cycle output, G02/G03
are inverted.
#6=1: In [START] menu screens, the tab of
[COORD CONV] is not displayed.
P27001 00000000 00000000
P27002 00000000 00000000
P27003 00000001 00000001 By setting this parameter, the
optimum cycle menus can be
displayed on the screen. Please set
1 bit only according to the machine
configuration.
#0=1 : Machining center X/Y/Z-axis
#1=0 : Machining center X/Y/Z/C/B-
axis
(B-axis : Tool tilting axis)
#2=0 : Machining center X/Y/Z/A
(A-axis : work rotation axis)/B-axis
(B-axis : Tool tilting axis)

#7,#3-#0
0xxx0001: 2 axes (XZ) lathe
0xxx0010: 3 axes (XZC) lathe
0xxx0100: 4 axes (XZCY) lathe

http://www.leadwell.com.tw/faq.php?mode=show&serialNum=78&faqSerialNum= 2009/3/13
Page 4 of 4

0xxx1000: 5 axes (XZCYB) lathe


1xxx0001: 2 axes (XZ) lathe with
sub spindle
1xxx0010: 3 axes (XZC) lathe with
sub spindle
1xxx0100: 4 axes (XZCY) lathe
with sub spindle
1xxx1000: 5 axes (XZCYB) lathe with sub
spindle
P27004 00000000 00000001 #0=1:
The following menus are displayed.
Hole Machining (G1000 to
G1006) or (G1110 to G1114)
Facing (G1020 to G1021)
Contouring (G1030 to G1033)
Pocketing (G1040 to G1043)
Grooving (G1050 to G1053)
XY-plane : Free figure (G1200
to G1206)
XY-plane : Hole position
(G1210 to G1217)
XY-plane : Fixed form figure (G1220 to
G1223)
P27060 00000000 00000010 #2=1: Method of interpolation during
roughing and bottom finishing(interpolation
of elements by extending them).
P27103 00000000 00000000 #0 : Lathe - X/Z-axis
#1 : Lathe - X/Z/C-axis

http://www.leadwell.com.tw/faq.php?mode=show&serialNum=78&faqSerialNum= 2009/3/13

You might also like