Aluminium motors

This product catalogue contains electrical and mechanical data


on the aluminium motor range available from ABB Motors. It can
be used in conjunction with the catalogue BA/Basic GB which
contains basic technical information about standard motors.
ABB Automation
Wärtsilä id: VPENC000053 -

Totally enclosed squirrel cage


three phase motors
Sizes 63 to 250, 0.18 to 75 kW
Section Page

Mechanical design 4
Stator
Drain holes
Terminal box
Connections
Bearings
Transport locking
Axially-locked bearing
Bearing life
Pulley diameter
Permissible loading on shaft
Lubrication

Electrical design 10
Stator winding temperature sensors
t6-times

Ordering information 11

Data tables, single-speed motors 12

Data at voltage ranges 20

Data table, two-speed motors


for fan drives 22

Data tables, two-speed motors with


highest output at both speeds 26

Motors with other no. of poles 29

Rating plates 30

Variant codes 31

Dimension drawings 36

Dimensions for alternative designs 52

Accessories 53

Aluminium motors in brief 55

ABB Motors product range 57

Cutaway view, M2AA 132 59-60

ABB Motors 61

ABB Motors reserves the right


to change the design, technical
specification and dimensions
without prior notice.

ABB Automation
Wärtsilä id: VPENC000053 -

Mechanical design
Stator
Stator framework, bearing shields and feet are made of Size 250-2 SMB, high output version, has cast iron feet
an extra corrosion resistant aluminium alloy with low and bearing shields.
copper content, with the following exceptions:
Size 250-2 SMA, basic version, has cast iron feet. The flange bearing shields of sizes 180 to 250 are
made of cast iron.

Drain holes
Motors that will be operated in very humid or wet Sizes 112 to 250 are provided with closable plastic
environments, and especially under intermittent duty, plugs in the drain holes (see diagram below). The plugs
should be provided with drain holes. The appropriate will be open on delivery. When mounting the motors, it
IM designation, such as IM 3031, is specified on the should be ensured that the drain holes face down-
basis of the method of mounting the motor. wards. In the case of vertical mounting, the upper plug
must be hammered home completely. In very dusty
In the basic design, sizes 63 to 100 are supplied
environments, both plugs should be hammered home.
without drain holes, with which they can be provided as
needed. If holes are drilled, the degree of protection will See variant codes 065, 066 and 076 under the
change to IP 54. If the motors are provided with special heading, “Drain holes”, on page 31.
felt plugs in the holes, the IP 55 will be retained.

Terminal box
Sizes 63 to 180 opening on the other side is provided with a cover
The terminal box is made of light metal alloy and is flange. The box can also be provided with an FL 13
located on top of the stator. The lower part of the box is opening towards the N-end.
integrated with the stator. It is provided with 2 knockout
The motors can also be provided with an extra large
openings on each side. Sizes 160-180 also have a
terminal box, standard for voltage code S. See variant
smaller opening. Cable glands are not included.
code 019, under the heading “Terminal box”, on page
Sizes 200 to 250 34. This will increase the dimension HD by 32 mm.
The terminal box and cover are made of deep drawn The box is supplied with two FL 21 openings. The right
steel and mounted on top of the stator. The box is opening is provided with a flange with two holes for Pr
bolted to the stator and is thus not rotatable. The size 54 cable glands. The holes are sealed by means of
of the box is the same in all motors. plastic plugs. Cable glands are not supplied. The
opening on the other side is provided with a cover
In the basic design, the terminal box is provided with
flange.
two FL 13 flange openings, one on each side. The
opening on the right side, seen from the D-end, is When new motors are manufactured, the terminal box
supplied with a flange with two holes for Pr 37 cable can be mounted on the left or the right side. See variant
glands. On delivery, the holes are sealed by means of code 021 and 180, under the heading “Terminal box”,
plastic plugs. Cable glands are not supplied. The on page 34.

4 ABB Motors
Wärtsilä id: VPENC000053 -
Connection openings Comparison of Pr and Pg
Motor Pr 15.4 Pg 9 Pr 37 Pg 29
size Opening Holes Pr 18.6 Pg 11 Pr 47 Pg 36
Pr 22.5 Pg 16 Pr 54 Pg 42
63 1)
4 x Pr 18.6 Pr 28.3 Pg 21
1)
71-100 4 x Pr 22.5
1)
112, 132 2 x (Pr 28.3 + Pr 22.5)
1)
160, 180 4 x Pr 37 + 2 x 15.4
200-250 2 x FL 13 2 x Pr 37
1
) Knockout openings.

Connections
The terminal block is provided with 6 terminals for
connecting Cu-cable. The terminals are marked in
accordance with IEC 34-8.
Terminal box
Motor Method of Maximum connectable
size connection For screw Cu-cable area, mm2

63-100 Screw terminal 2.5


112, 132 Cable lug M5 10
160, 180 Cable lug M6 35
200-250 Cable lug M 10 70

Bearings
The motors are provided with bearings, according to in such cases, the axial force must only operate in one
the tables below. direction.
Greater axial forces can be tolerated if the motors are Motor versions with roller bearings tolerate greater
provided with angular contact ball bearings. Note that radial forces.

Basic version with deep groove ball


bearings
Basic design motors High-output motors
Single-speed motors Two-speed motors Single-speed motors
Motor Foot- and flange-mounted motor Foot- and flange-mounted motor Motor Foot- and flange-mounted motor
size D-end N-end D-end N-end size D-end N-end

63 6202-2Z/C3 6202-2Z/C3 6202-2Z/C3 6202-2Z/C3 71 6203-2Z/C3 6202-2Z/C3


71 6203-2Z/C3 6202-2Z/C3 6203-2Z/C3 6202-2Z/C3 80 6204-2Z/C3 6203-2Z/C3
80 6204-2Z/C3 6203-2Z/C3 6204-2Z/C3 6203-2Z/C3 90 6305-2Z/C3 6204-2Z/C3
90 6305-2Z/C3 6204-2Z/C3 6305-2Z/C3 6204-2Z/C3 100 6306-2Z/C3 6205-2Z/C3
100 6306-2Z/C3 6205-2Z/C3 6306-2Z/C3 6205-2Z/C3 112 6206-2Z/C3 6206-2Z/C3
112 6206-2Z/C3 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 132 6208-2Z/C3 6208-2Z/C3
160 6309-2Z/C3 6209-2Z/C3
132 S 6208-2Z/C3 6206-2Z/C3 6208-2Z/C3 6206-2Z/C3 180 6310-2Z/C3 6209-2Z/C3
132 M 6208-2Z/C3 6206-2Z/C3 6208-2Z/C3 6208-2Z/C3
160 6309-2Z/C3 6209-2Z/C3 6309-2Z/C3 6209-2Z/C3 200 6312/C3 6210/C3
180 6310-2Z/C3 6209-2Z/C3 6310-2Z/C3 6209-2Z/C3 225 6313/C3 6212/C3
250 6315/C3 6213/C3
200 6312/C3 6210/C3 6312/C3 6210/C3
225 6313/C3 6212/C3 6313/C3 6212/C3
250 6315/C3 6213/C3 6315/C3 6213/C3

Alternative design
63-series bearings at the D-end Version with roller bearings.
Standard for sizes 90, 100, and 200 to 250. It is recommended to use roller bearings in belt drives
See variant code 188, under the heading “Bearings for motor sizes 160 - 250.
and lubrication”, on page 31.

ABB Motors 5
Wärtsilä id: VPENC000053 -
Version with roller bearings
See variant code 037, under the heading “Bearings and
lubrication”, on page 31.

Basic design motors High-output motors


Single-speed motors Two-speed motors Single-speed motors
Motor Foot- and flange-mounted motor Foot- and flange-mounted motor Motor Foot- and flange-mounted motor
size D-end N-end D-end N-end size D-end N-end

160 NU 209 ECP - NU 209 ECP - 160 NU 209 ECP -


180 NU 210 ECP - NU 210 ECP - 180 NU 210 ECP -
200 NU 312 ECP - NU 312 ECP - 200 NU 312 ECP -
225 NU 313 ECP - NU 313 ECP - 225 NU 313 ECP -
250 NU 315 ECP - NU 315 ECP - 250 NU 315 ECP -

Version with angular contact ball bearings


See variant codes 058 and 059, under the heading
“Bearings and lubrication”, on page 31.

Basic design motors High-output motors


Single-speed motors Two-speed motors Single-speed motors
Foot- and flange-mounted motor Foot- and flange-mounted motor Foot- and flange-mounted motor
Motor D-end N-end D-end N-end Motor D-end N-end
size 058 059 058 059 size 058 059

112 7206 BE 7205 BE 7206 BE 7206 BE 112 7206 BE 7206 BE


132 7208 BE 7206 BE 7208 BE 7208 BE 132 7208 BE 7208 BE
160 7309 BE 7209 BE 7309 BE 7209 BE 160 7309 BE 7209 BE
180 7310 BE 7210 BE 7310 BE 7210 BE 180 7310 BE 7209 BE
220 - 7210 BE - 7210 BE 200 - 7210 BE
225 - 7212 BE - 7212 BE 225 - 7212 BE
250 - 7213 BE - 7213 BE 250 - 7213 BE

Transport locking
Motors provided with roller bearings or angular contact damage to the bearings, due to vibration, during
ball bearings are fitted with a transport lock to prevent transport.

Axially-locked bearings
The table below shows which of the motor’s bearings is
axially locked in the bearing seat, by an inner bearing
cover.
See also variant code 042, under the heading
“Bearings and lubrication”, on page 31.

Motor Foot-mounted Flange-mounted motors


size motors Large flange Small flange

1) 1)
63-80 D-end
90, 100 D-end D-end D-end
1)
112, 132 D-end D-end
160-180 D-end D-end -
200-250 N-end N-end -
1
) Foot motor. A spring-washer at the N-end presses the rotor toward the D-end.

6 ABB Motors
Wärtsilä id: VPENC000053 -
Bearing life
The nominal life is defined as the number of hours that Permissible force at changed bearing life or supply frequency
are attained or exceeded by 90% of identical bearings,
in a large test series, under certain specified conditions. Bearing life in hours at
50% of the bearings attain a life of as much as 5 times Permissible force, as percentage of
50 Hz 60 Hz value in table on page 8 and 9
this figure.
The life of bearings is dependent on various factors, 25000 21000 100% of value
such as bearing load, motor speed, operating tempera- for 25000 hours
ture and the purity of the grease. The permissible radial 40000 33000 100% of value
and axial loading for different motor sizes is shown in for 40000 hours
the table on page 8 and 9. 63000 52000 86% of value
for 40000 hours
The table is valid for 50 Hz. For 60 Hz and/or some
other bearing life than is specified in the table, the 80000 67000 80% of value
values are changed according to the table on the right. for 40000 hours

The table values assume the occurrence of only radial


(FR) or axial (FA) forces. In the case of simultaneous
radial and axial forces, information can be supplied on
request. It is assumed that the radial force, FR, is
applied at the end of the motor shaft, according to the
diagram on the right.
LLX
FRX = FR • —————
LLX – X

where:
LLX = distance between end of motor shaft extension
at D-end and centre of bearing at N-end.
X = distance between end of motor shaft extension LLX values for basic design of single-speed motors
at D-end and centre of pulley. Motor LLX E Motor LLX E
size mm mm size mm mm
In the case of forces applied beyond the end of the
shaft, information can be supplied on request. 63 164 30
71 181 30
80 208 40
90 245 50
100 282 60
112 M 284 60
112 MB 316 60
132 S(A, B) 366 80
132 M(A) 366 80
132 MB-6 366 80
132 SC 402.5 80
132 MB-4, 8 402.5 80
132 MC 482.5 80
160 M 2-8 506.3 110
160 M 2/4, 4/6, 4/8 506.3 110
160 MA 2, 8, 2/4 506.3 110

Pulley diameter
When the desired bearing life has been determined, the
minimum permissible pulley diameter can be calculated
with FR (or FRX), according to the formula:

1.9 • 107 • K • P
D=
n • FR(X)

where:
D = diameter of pulley, mm
P = power requirement, kW FR = permissible radial force according to the table
n = motor speed, r/min. on page 8 and 9.
K = belt tension factor, dependent on belt type and FRX = permissible radial force according to the
type of duty. A common value for V-belts is formula under the heading “Bearing life”,
K = 2.5 above.

ABB Motors 7
Wärtsilä id: VPENC000053 -
Permissible loading on shaft
Permissible axial force FA and radial force FR
The table values for FA apply to horizontal mounting. In the case of vertical mounting, consideration must be given
to the rotor weight, according to note 2. The bearing life, L10, is calculated according to SKF’s new theory on
bearing life, L10aah, which also takes the purity of the grease into consideration. An adequate lubrication is a
necessary prerequisite for the table below.

Ball bearings Roller bearings


Basic design with deep Alternative design Alternative design
groove ball bearings with 63-series bearings with roller bearings
25000 hrs 40000 hrs 25000 hrs 40000 hrs 25000 hrs 40000 hrs
Rotor weight
Motor No. of FGR FA FR FA FR FA FR FA FR FA FR FA FR
size poles N N N N N N N N N N N N N

631) 2 590 400 520 400


4 665 400 580 400
8 695 400 600 400
711) 2 735 570 650 570
4 820 570 720 570
6 885 570 770 570
8 880 570 765 570
801) 2 1005 750 885 750
4 1120 750 995 750
6 1205 750 1050 750
8 1240 750 1075 750
901) 3) 2 1835 1200 1625 1200
4 2055 1200 1805 1200
6 2210 1200 1930 1200
8 2285 1200 1985 1200
1001) 3) 2 2370 1800 2100 1800
4 2645 1800 2330 1800
6 2830 1800 2480 1800
8 2925 1800 2555 1800
112 M1) 2 64 1500 1420 1320 1280 2230 1700 1970 1700
4 84 1600 1410 1390 1250 2410 1700 2110 1700
6 85 1730 1510 1500 1340 2590 1700 2260 1700
8 89 1750 1530 1510 1360 2680 1700 2320 1700
112 MB1) 2 85 1530 1470 1340 1330 2250 1700 1990 1700
4 106 1600 1430 1390 1260 2410 1700 2110 1700
6 107 1720 1520 1490 1340 2590 1700 2250 1700
8 107 1760 1560 1520 1370 2680 1700 2320 1700
132 SA1) 2 89 2570 2360 2260 2140 3460 3180 3070 2870
132 SB1) 2 101 2570 2360 2260 2130 3460 3170 3070 2870
132 SC1) 2 143 2520 2430 2210 2200 3410 3200 3020 2960
132 S1) 4 138 2770 2440 2440 2180 3770 3200 3320 2990
132 M1) 4 160 2750 2410 2420 2150 3750 3200 3290 2950
132 MB1) 4 211 2680 2440 2340 2170 3670 3200 3220 3000
132 S1) 6 140 2950 2560 2580 2270 4020 3200 3520 3120
132 MA1) 6 165 2940 2530 2570 2250 4010 3200 3500 3100
132 MB1) 6 197 2910 2500 2550 2220 3980 3200 3480 3070
132 MC1) 6 214 2830 2510 2460 2220 3900 3200 3400 3090
132 S1) 8 165 3040 2630 2650 2330 4150 3200 3610 3200
132 M1) 8 197 3020 2590 2630 2300 4130 3200 3590 3170
132 MB1) 8 214 2940 2630 2560 2330 4050 3200 3520 3200
160 MA1) 2 211 4730 3500 4220 3500 3050 3500 2720 3500
8 280 5240 3500 4640 3500 3400 3500 3100 3500
160 M1) 2 227 4730 3500 4220 3500 3060 3500 2710 3500
4 270 5230 3500 4640 3500 3370 3500 3000 3500
6 320 5220 3500 4630 3500 3330 3500 2970 3500
8 320 5220 3500 4630 3500 3330 3500 2970 3500
160 L1) 2 277 5240 3500 4650 3500 3350 3500 2980 3500
4 338 5220 3500 4630 3500 3330 3500 2970 3500
6 374 5050 3500 4470 3500 3150 3500 2760 3500
8 445 4720 3500 4740 3500 3590 3500 3170 3500
160 LB1) 2 296 5240 3500 4650 3500 3350 3500 2980 3500
4 374 5050 3500 4470 3500 3150 3500 2760 3500
6 445 4720 3500 4740 3500 3590 3500 3170 3500
8 445 4720 3500 4740 3500 3590 3500 3170 3500
180 M1) 2 332 4660 5550 4250 5110 2820 5900 2420 5900
4 451 4950 5710 4500 5200 3120 5900 2660 5900
1
) For motor sizes 63 to 180, axial tension in the direction of the shaft is 2
) Method of mounting Direction of force Permissible axial force
assumed. The specified values take the weight of the rotor and the
effects of the spring washer at the N-end into consideration. Horizontal Horizontal FA according to table
3
) Basic design with 63-series bearings at the D-end. Vertical Downwards FA – rotor weight FGR1)
Vertical Upwards FA + rotor weight FGR1)

8 ABB Motors
Wärtsilä id: VPENC000053 -
Permissible axial force FA and radial force FR – contd.
Ball bearings Roller bearings
Basic design with deep Alternative design Alternative design
groove ball bearings with 63-series bearings with roller bearings
25000 hrs 40000 hrs 25000 hrs 40000 hrs25000 hrs 40000 hrs
Rotor weight
Motor No. of FGR FA FR FA FR FA FR FA FR FA FR FA FR
size poles N N N N N N N N N N N N N

180 L1) 4 522 4870 5670 4390 5150 3030 5900 2560 5900
6 571 5200 5900 4710 5500 3360 5900 2870 5900
8 561 5370 5900 4850 5570 3540 5900 3010 5900
180 LB1) 2 382 4660 5550 4250 5110 2820 5900 2420 5900
4 602 4870 5670 4390 5150 3030 5900 2560 5900
6 610 5200 5900 4710 5500 3360 5900 2870 5900
8 606 5370 5900 4850 5570 3540 5900 3010 5900
200 MLA3) 2 490 1600 4070 1360 3600 1600 7790 1360 7790
4 638 1750 4410 1480 3860 1750 7790 1480 7790
6 697 1870 4600 1590 3990 1870 7790 1590 7790
8 765 1880 4680 1570 4040 1880 7790 1570 7790
200 MLB3) 2 559 1570 4060 1340 3590 1570 7790 1340 7790
4 746 1670 4360 1400 3810 1670 7790 1400 7790
6 785 1800 4540 1510 3940 1800 7790 1510 7790
8 883 1870 4670 1470 4030 1780 7790 1470 7790
200 MLC3) 2 579 1560 4050 1330 3590 1560 7790 1330 7790
6 873 1670 4430 1380 3820 1670 7790 1380 7790
225 SMA3) 4 746 2490 4930 2130 4320 2490 8300 2130 8300
8 893 2790 5420 2380 4700 2790 8300 2380 8300
225 SMB3) 2 697 2200 4530 1890 4010 2200 8900 1890 8900
4 814 2440 4870 2070 4260 2440 8300 2070 8300
6 691 2570 5080 2170 4400 2570 8300 2170 8300
8 971 2720 5350 2310 4630 2720 8300 2310 8300
225 SMC3) 2 765 2170 4510 1860 3990 2170 8900 1860 8900
4 942 2360 4840 1980 4230 2360 8300 1980 8300
6 1090 2465 5020 2065 4340 2460 8300 2060 8300
8 1110 2580 5230 2160 4500 2580 8300 2160 8300
250 SMA3) 2 824 2620 5620 2250 4980 2620 9100 2250 9100
4 971 2970 6200 2530 5440 2970 11550 2530 11550
6 1235 3100 6430 2630 5590 3100 11550 2630 11550
8 1255 3230 6650 2740 5760 3230 11550 2740 11550
250 SMB3) 2 942 2570 5610 2210 4960 2570 9100 2210 9100
4 1175 2860 6140 2410 5380 2860 11550 2410 11550
6 1430 2985 6400 2500 5560 2980 11550 2500 11550
8 1450 3080 6590 2570 5700 3080 11550 2570 11550
1 2
) For motor sizes 63 to 180, axial tension in the direction of the shaft is ) Mounting arrangement Direction of force Permissible axial force
assumed. The specified values take the weight of the rotor and the Horizontal Horizontal FA according to table
effects of the spring washer at the N-end into consideration. Vertical Downwards FA – rotor weight FGR1)
3)
Vertical Upwards FA + rotor weight FGR1)
Basic design with 63-series bearings at the D-end.

Lubrication
On delivery, the motors are lubricated with a type of with grease nipples for both bearings. See variant code
grease intended for use in dry or humid environments, 041, under the heading “Bearings and lubrication”, on
at normal ambient temperatures. Motor sizes 63 to 100 page 31.
are lubricated for bearing temperatures of between -25
The basic design of motor sizes 200 to 250 have
to +150°C. Motor sizes 112 to 250 are lubricated for
provision for bearing lubrication during service.
bearing temperatures of between -30 to +110°C. See
Lubrication intervals and grease quantities are
also variant codes 039 and 40, under the heading
specified on a plate on the motor as well as in the
“Bearings and lubrication”, on page 31.
instructions for maintenance supplied with the motor.
Information about ambient temperature applies to
standard motors according to insulation class F and The lubrication interval is defined as the period after
temperature rise class B. which 99% of the bearings still have enough lubrication,
L01. At double the time 90% of the motors still have
On request, motor sizes 112 to 180 can be provided
adequate lubrication. (L10)

Motors without valve lubrication


Hours of operation during which the bearings still have adequate lubrication, L01. (Adequate lubrication, however max. 5 years)
Ambient temperature: 25 °C Ambient temperature: 40 °C
Motor Motor size Motor size
speed
r/min 63-100 112, 132 160, 180 63-100 112, 132 160, 180

3000 26000 22000 16000 21000 11000 8000


1500 44000 42000 32000 34000 21000 16000
1000 44000 44000 42000 40000 23000 21000
750 44000 44000 44000 43000 27000 22500

ABB Motors 9
Wärtsilä id: VPENC000053 -

Electrical design
Stator winding temperature
sensors
Motors frame size 200-250 have as standard 3 PTC winding. For other sizes see under the heading "Stator
thermistors for 150 °C connected in series in the stator winding temperature sensors" on page 33 and 34.

t6- times for setting of motor t6-times in seconds

protection Motor size 2 poles 4 poles 6 poles 8 poles

63-80 The starting current of sizes 63 to 80, 2 to 8 poles,


Setting of certain electronic motor protection devices and sizes 90 to 100, 4 to 8 poles, is <6 x the rated
requires knowledge of the t6 time. current.
t6 is defined as the acceptable time, from thermal 90 9
considerations, for which a motor can withstand the 100 10
locked rotor condition with a supply current equal to 6 112 M 15 12 13 11
times the rated value. 132 S - 12 15 12
132 SA 17 - - -
Note: the starting current of some smaller motor sizes 132 SB 16 - - -
with normal supply voltage is less than 6 times the
132 M - 12 - 13
rated value. 132 MA - - 13 -
132 MB - - 14 -
160 MA 35 - - 27
160 M 27 16 21 17
160 L 26 17 17 17
160 LB 16 16 15 15
180 M 25 20 - -
180 L - 20 23 31
180 LB 18 17 19 27
200 MLA 25 29 24 26
200 MLB 21 28 23 21
200 MLC 16 - 20 -
225 SMA - 23 - 24
225 SMB 26 20 20 20
225 SMC 20 19 24 24
250 SMA 18 28 27 24
250 SMB 20 18 27 24

Sophisticated winding machinery is used to produce


the stators of ABB Motors standard pole products, such
as M2AA range, shown.

10 ABB Motors
Wärtsilä id: VPENC000053 -

Ordering information
Sample order
When placing an order, the motor type, size and product code must be specified. The product
code of the motor is composed in accordance with the following example.
Motor size

A B C D, E, F A Motor type
B Motor size
M2AA 112 M 3GAA 112 001 - ADA, 032, 043, etc. C Product code
D Code for mounting
1 2 3 4 5 6 7 8 9 101112 13 14... arrangement
E Voltage and frequency
code
F Generation code
followed by variant
codes

Explanation of the product code


Positions 1 and 2 Positions 8 to 10
3G = Business area ABB Motors Serial number
Position 3 Position 11
Enclosure and stator frame material - (dash)
A = Totally enclosed motor with aluminium stator frame
Position 12
Position 4 Mounting arrangement
Type of rotor A = Foot-mounted motor
A = Squirrel cage rotor B = Flange-mounted motor. Large flange with
Positions 5 and 6 clearance holes.
IEC size C = Flange-mounted motor. Small flange with tapped
holes.
06 = 63 11 = 112 22 = 225 F = Foot- and flange-mounted motor. Special flange.
07 = 71 13 = 132 25 = 250 H = Foot- and flange-mounted motor. Large flange with
08 = 80 16 = 160 clearance holes.
09 = 90 18 = 180 J = Foot- and flange-mounted motor. Small flange with
10 = 100 20 = 200 tapped holes.
V = Flange-mounted motor. Special flange.
Position 7
Pole pairs Position 13
1 = 2 poles 5 = 10 poles Voltage and frequency
2 = 4 poles 6 = 12 poles See appropriate pages with tables
3 = 6 poles 7 = >12 poles
4 = 8 poles 8 = Two-speed motors Position 14
9 = Multi-speed motors Version
A = Generation code followed by variant codes

ABB Motors 11
Wärtsilä id: VPENC000053 -
Totally enclosed squirrel cage
three phase motors, aluminium frame
IP 55 IC 411

400 V 50 Hz

Current Torque
Effi- Power
IN IS TN TS Tmax
Output Motor type Product code Speed ciency factor
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN

3000 r/min = 2 poles Basic design


0.25 63 B 061 001- 2820 70.6 0.75 0.70 4.0 0.85 2.2 2.7
0.25 63 B1) 061 002- 2820 70.6 0.75 0.70 4.0 0.85 2.2 2.7
0.37 71 A 071 001- 2840 72.7 0.80 0.93 4.5 1.25 2.2 2.7
0.55 71 B 071 002- 2850 76.1 0.80 1.33 5.0 1.9 2.2 2.7
0.75 80 A 081-001- 2860 78.8 0.82 1.7 5.0 2.5 2.2 2.7
1.1 80 B 081 002- 2870 80.1 0.85 2.4 5.5 3.7 2.4 3.0
1.5 90 S 091 001- 2870 80.1 0.82 3.35 5.5 5.0 2.4 3.0
2.2 90 L 091 002- 2870 82.8 0.86 4.55 7.0 7.5 2.7 3.4
3 100 L 101 001- 2900 83.8 0.88 5.95 7.5 10.0 2.7 3.6
4 112 M 111 001- 2850 86 0.91 7.4 7.5 13.4 2.8 3.0
5.5 132 SA 131 001- 2855 86 0.88 10.5 7.8 18.4 3.2 3.4
7.5 132 SB 131 002- 2855 87 0.90 13.9 8.5 25.1 3.4 3.6
11 160 MA 161 101- 2930 91.2 0.88 20.0 6.3 36 1.9 2.5
15 160 M 161 102- 2920 91.7 0.90 26.5 6.6 49 2.3 2.5
18.5 160 L 161 103- 2920 92.4 0.91 32 7.3 60 2.6 2.7
22 180 M 181 101- 2930 92.8 0.89 38.5 7.2 71 2.5 2.7
30 200 MLA 201 001- 2955 93.2 0.88 53 7.3 97 2.4 3.1
37 200 MLB 201 002- 2950 93.6 0.89 64 7.3 120 2.5 3.2
45 225 SMB 221 001- 2960 93.9 0.88 79 7.3 145 2.5 2.8
55 250 SMA 251 001- 2970 94.4 0.89 95 7.5 177 2.0 3.0

2)
3000 r/min = 2 poles High-output design
0.753) 71 C 071 003- 2820 77.1 0.80 1.75 5.0 2.5 2.2 2.7
1.53) 80 C 081 003- 2840 80.1 0.87 3.15 5.5 5.0 2.3 2.8
2.73)4) 90 LB 091 003- 2860 80.7 0.86 5.7 7.0 9.0 2.6 3.2
43) 100 LB 101 002- 2900 84.1 0.86 8.1 7.5 13.0 2.7 3.6
5.53) 112 MB 111 002- 2855 86.5 0.93 9.9 7.3 18.4 2.7 2.9
9.23) 132 SBB 131 004- 2840 85.9 0.93 16.6 7.8 31 2.7 3.0
113) 132 SC 131 003- 2835 87.0 0.93 19.6 8.0 37 3.2 3.3
223) 160 LB 161 104- 2920 92.1 0.91 38 7.1 72 2.6 2.6
303) 180 LB 181 102- 2945 93.7 0.89 53 8.3 97 3.1 3.4
45 200 MLC 201 003- 2950 93.8 0.89 78 7.3 146 2.6 3.3
55 225 SMC 221 002- 2960 94.3 0.89 95 7.0 177 2.5 2.9
75 250 SMB 251 002- 2970 95.2 0.90 127 7.3 241 2.1 3.0
1
) Shaft Ø14 mm, large flange F 130.
2
) High-output design
The output of these motors is one step higher than the basic design
with rated outputs in accordance with CENELEC. Motor sizes 112 to 132 are
somewhat longer than the basic design.
3
) Temperature rise class F.
4
) Lower than CENELEC +1.
The bullet indicates a 3-letter product code supplement for choice of mounting arrangement
(page 11, pos. 12), voltage and frequency (below) and generation code (page 11, pos. 14).
Code letters for supplementing the product code
Code letter for voltage and frequency
Direct start or, with ∆−connection, also Y/∆-start
Motor S D H E F T U X
size 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz

63-100 220-240 V∆ 380-420 V∆ 440-480 V∆ - 500 V∆ 500 VY 660 V∆1) 690 V∆1) Other rated
380-420 VY 440-480 VY 660-690 VY - voltage,
112-132 220-240 V∆ - 380-420 V∆ 440-480 V∆ 415 V∆ 500 V∆ 660 V∆ 690 V∆ connection
380-420 VY 440-480 VY 660-690 VY - or frequency,
160-250 220, 230 V∆ - 380,400,415V∆ 440 V∆ 415 V∆ 500 V∆ 660 V∆ 690 V∆ 690 V maximum
380,400,415 VY 440 VY 660, 690 VY −
1
) On request.

12 ABB Motors
Wärtsilä id: VPENC000053 -

Insulation class F
Temperature rise class B

380 V 50 Hz 415 V 50 Hz

Moment Weight Sound


Effi- Power Current Effi- Power Current of inertia Foot-mounted pressure level
Output Speed ciency factor IN Speed ciency factor IN J = 1/4 GD2 motor Lp
kW r/min % cos ϕ A r/min % cos ϕ A kgm2 kg dB(A)

3000 r/min = 2 poles Basic design


0.25 2790 70.7 0.79 0.70 2830 69.7 0.69 0.72 0.00018 4.5 48
0.25 2790 70.7 0.79 0.70 2830 69.7 0.69 0.72 0.00018 4.5 48
0.37 2830 72.5 0.84 0.93 2860 72.4 0.77 0.95 0.0004 5.5 55
0.55 2830 76 0.84 1.32 2870 75.3 0.75 1.37 0.0005 6.5 55
0.75 2840 77.9 0.85 1.73 2880 78.6 0.8 1.7 0.0009 9 58
1.1 2850 79.3 0.88 2.43 2890 80.1 0.81 2.42 0.0011 10 58
1.5 2850 79.7 0.88 3.40 2890 79.8 0.79 3.4 0.0019 13 63
2.2 2850 81.8 0.89 4.70 2890 82.9 0.82 4.57 0.0024 16 63
3 2890 82.9 0.90 6.2 2910 84.1 0.85 5.95 0.0041 21 68
4 2830 85.0 0.92 7.80 2865 86.5 0.90 7.2 0.010 25 63
5.5 2835 85.0 0.90 10.9 2870 86.5 0.87 10.2 0.014 37 69
7.5 2835 86.0 0.91 14.7 2870 87.5 0.88 13.6 0.016 42 69
11 2915 90.8 0.89 20.5 2935 91.3 0.86 19.4 0.039 73 69
15 2905 91.2 0.90 27.5 2925 92.0 0.89 25.5 0.047 84 69
18.5 2910 92.0 0.91 33.5 2930 92.6 0.90 31 0.053 94 69
22 2930 92.4 0.90 40.5 2945 93.0 0.88 37.5 0.077 119 69
30 2955 93.1 0.89 55 2960 93.3 0.86 52 0.15 175 72
37 2950 93.4 0.89 68 2955 93.7 0.87 63 0.18 200 72
45 2955 93.7 0.89 82 2965 93.9 0.87 77 0.26 235 74
55 2960 94.3 0.89 100 2970 94.5 0.88 92 0.49 285 75

2)
3000 r/min = 2 poles High-output design
0.753) 2800 76.8 0.85 1.8 2840 77.7 0.77 1.8 0.0006 7.5 55
1.53) 2820 78.6 0.88 3.3 2860 80.6 0.84 3.15 0.0013 11 58
2.73)4) 2840 80.2 0.89 5.8 2870 80.6 0.83 5.7 0.0027 18 63
43) 2890 83.9 0.88 8.3 2910 85.8 0.84 7.8 0.005 25 68
5.53) 2835 85.5 0.93 10.5 2865 87.5 0.92 9.5 0.012 33 63
9.23) 0.019 50
113) 2815 86.5 0.92 21 2845 88.0 0.92 18.9 0.022 56 69
3)
22 2910 91.6 0.91 40 2925 92.4 0.90 37 0.058 100 69
303) 2940 93.5 0.90 55 2950 93.8 0.87 52 0.092 137 70
45 2935 93.5 0.89 82 2955 93.8 0.88 76 0.19 205 72
55 2950 94.2 0.89 100 2965 94.3 0.88 92 0.29 260 74
75 2965 95.0 0.90 134 2970 95.3 0.89 123 0.57 330 75
3
) Temperature rise class F.
4
) Lower than CENELEC +1.

Recalculation factors
Recalculation factors for current at rated voltages other than 400 V 50 Hz
Rated voltage at 50 Hz
and motor wound for Recalculation factor

220 V 1.82
230 V 1.74
415 V 0.96
500 V 0.80
660 V 0.61
690 V 0.58

ABB Motors 13
Wärtsilä id: VPENC000053 -
Totally enclosed squirrel cage
three phase motors, aluminium frame
IP 55 IC 411

400 V 50 Hz

Current Torque
Effi- Power IN IS TN TS Tmax
Output Motor type Product code Speed ciency factor
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN

1500 r/min = 4 poles Basic design


0.18 63 B 062 001- 1370 58.7 0.63 0.72 3.0 1.25 2.2 2.6
0.18 63 B1) 062 002- 1370 58.7 0.63 0.72 3.0 1.25 2.2 2.6
0.25 71 A 072 001- 1400 66.8 0.67 0.83 3.5 1.7 2.2 2.7
0.37 71 B 072 002- 1410 70.5 0.69 1.12 4.0 2.5 2.2 2.7
0.55 80 A 082 001- 1420 74 0.73 1.45 4.0 3.7 2.2 2.7
0.75 80 B 082 002- 1420 77 0.74 1.9 4.5 5.0 2.2 2.7
1.1 90 S 092 001- 1410 77.5 0.81 2.59 5.0 7.5 2.2 2.7
1.5 90 L 092 002- 1420 80.3 0.79 3.45 5.0 10.0 2.4 2.9
2.2 100 LA 102 001- 1430 81.7 0.81 4.8 5.5 15.0 2.4 2.9
3 100 LB 102 002- 1430 83.5 0.81 6.48 5.5 20.0 2.5 2.9
4 112 M 112 001- 1435 84.5 0.80 8.6 7.0 26.6 2.9 3.1
5.5 132 S 132 001- 1450 87.0 0.83 11.1 7.3 36.2 2.2 3.0
7.5 132 M 132 002- 1450 88.0 0.83 14.8 7.9 49.4 2.5 3.2
11 160 M 162 101- 1460 90.3 0.81 21.5 6.7 72 2.9 2.8
15 160 L 162 102- 1455 91.1 0.84 28.5 6.8 98 3.0 2.8
18.5 180 M 182 101- 1470 92.3 0.84 35 7.0 120 3.1 2.7
22 180 L 182 102- 1470 92.4 0.83 41 7.0 143 2.9 2.8
30 200 MLA 202 001- 1475 92.9 0.83 56 6.7 194 2.6 2.8
37 225 SMA 222 001- 1480 93.6 0.84 68 6.6 239 2.4 2.5
45 225 SMB 222 002- 1480 94.2 0.83 83 6.7 290 2.7 2.6
55 250 SMA 252 001- 1480 94.6 0.86 98 7.5 355 2.3 2.8

2)
1500 r/min = 4 poles High-output design
0.553) 71 C 072 003- 1380 72.5 0.73 1.5 4.0 3.7 2.2 2.4
1.13) 80 C 082 003- 1380 76.1 0.80 2.65 4.5 7.5 2.0 2.2
1.853)4) 90 L 092 003- 1390 79.5 0.80 4.4 4.5 13.0 2.2 2.4
2.23) 90 LB 092 004- 1390 80.3 0.83 4.85 4.5 15.0 2.2 2.4
43) 100 LC 102 003- 1420 82.7 0.82 8.73 5.5 27.0 2.5 2.8
5.53) 112 MB 112 002- 1425 84.5 0.83 11.4 7.1 36.9 2.8 3.1
9.23) 132 MBA 132 004- 1445 86.5 0.87 17.5 8.0 61 2.5 2.7
113) 132 MB 132 003- 1450 88.0 0.86 21 8.3 72.4 3.0 2.7
18.53) 160 LB 162 103- 1450 90.5 0.84 36 6.9 122 2.9 2.9
303) 180 LB 182 103- 1465 92.5 0.84 56 6.9 195 3.2 2.8
37 200 MLB 202 002- 1475 93.4 0.84 68 7.8 236 3.6 3.2
55 225 SMC 222 003- 1480 94.6 0.84 100 7.3 355 3.1 2.8
75 250 SMB 252 002- 1480 95.0 0.86 132 7.0 484 2.4 3.0

1
) Shaft Ø14 mm, large flange F 130. 2) High-output design The output of these motors is one step higher than the basic design with rated outputs in accordance
with CENELEC. Motor sizes 112 to 132 are somewhat longer than the basic design. 3) Temperature rise class F. 4) Lower than CENELEC +1.

The bullet indicates a 3-letter product code supplement for choice of mounting arrangement
(page 11, pos. 12), voltage and frequency (below) and generation code (page 11, pos. 14).

Code letters for supplementing the product code


Code letter for voltage and frequency
Direct start or, with ∆−connection, also Y/∆-start
Motor S D H E F T U X
size 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz

63-100 220-240 V∆ 380-420 V∆ 440-480 V∆ - 500 V∆ 500 VY 660 V∆1) 690 V∆1) Other rated
380-420 VY 440-480 VY 660-690 VY - voltage,
112-132 220-240 V∆ - 380-420 V∆ 440-480 V∆ 415 V∆ 500 V∆ 660 V∆ 690 V∆ connection
380-420 VY 440-480 VY 660-690 VY - or frequency,
160-250 220, 230 V∆ - 380,400,415V∆ 440 V∆ 415V∆ 500 V∆ 660 V∆ 690V∆ 690 V maximum
380,400,415 VY 440 VY 660, 690 VY −
1
) On request.

14 ABB Motors
Wärtsilä id: VPENC000053 -

Insulation class F
Temperature rise class B

380 V 50 Hz 415 V 50 Hz

Moment Weight Sound


Effi- Power Current Effi- Power Current of inertia Foot-mounted pressure level
Output Speed ciency factor IN Speed ciency factor IN J = 1/4 GD2 motor Lp
kW r/min % cos ϕ A r/min % cos ϕ A kgm2 kg dB(A)

1500 r/min = 4 poles Basic design


0.18 1370 60.6 0.68 0.68 1370 56.9 0.60 0.75 0.00028 4.5 37
0.18 1370 60.6 0.68 0.68 1370 56.9 0.60 0.75 0.00028 4.5 37
0.25 1400 67.9 0.72 0.80 1410 65.4 0.63 0.89 0.00073 5.5 45
0.37 1400 70.8 0.74 1.11 1420 69.7 0.66 1.15 0.00098 6.5 45
0.55 1410 73.6 0.78 1.45 1420 73.5 0.70 1.48 0.0017 9 48
0.75 1410 76.4 0.78 1.90 1430 76.7 0.70 1.95 0.0021 10 48
1.1 1410 76.3 0.83 2.66 1430 77.7 0.76 2.60 0.0032 13 50
1.5 1420 79.9 0.82 3.5 1430 80.3 0.77 3.45 0.0043 16 50
2.2 1430 80.6 0.85 4.96 1430 81.8 0.78 4.85 0.0069 21 54
3 1430 82.6 0.85 6.61 1430 83.1 0.77 6.55 0.0082 24 54
4 1425 84.0 0.83 8.7 1440 85.0 0.75 8.80 0.015 27 56
5.5 1445 86.0 0.85 11.5 1455 87.5 0.81 10.9 0.031 40 59
7.5 1445 87.0 0.86 15.3 1455 88.0 0.82 14.5 0.038 48 59
11 1450 89.9 0.83 22.5 1465 90.5 0.79 21.5 0.067 75 62
15 1445 90.6 0.84 30.0 1460 91.4 0.83 28 0.091 94 62
18.5 1465 91.7 0.85 36.0 1470 92.2 0.83 34.0 0.161 124 62
22 1465 92.1 0.85 42.5 1475 92.6 0.82 40.0 0.191 141 63
30 1470 92.6 0.83 59 1475 93.0 0.83 54 0.29 180 63
37 1475 93.4 0.84 72 1480 93.7 0.81 68 0.37 215 66
45 1475 94.0 0.85 86 1480 94.2 0.81 82 0.42 230 66
55 1475 94.3 0.86 103 1480 94.7 0.84 96 0.72 275 67

2)
1500 r/min = 4 poles High-output design
0.553) 1370 71.9 0.78 1.51 1390 72.5 0.68 1.55 0.0012 7.5 45
1.13) 1370 73.7 0.84 2.76 1400 76.8 0.76 2.6 0.0024 11 48
1.853)4) 1380 78.8 0.83 4.4 1400 79.5 0.76 4.35 0.0043 16 50
2.23) 1380 78.4 0.85 5.1 1400 80.8 0.80 4.9 0.0048 17 50
43) 1410 81.5 0.85 8.89 1420 82.9 0.77 8.8 0.009 25 54
5.53) 1415 84.5 0.85 11.7 1430 85.5 0.79 11.4 0.018 34 56
9.23) 0.048 59
113) 1445 87.5 0.87 22 1455 88.5 0.83 21 0.048 59 59
3)
18.5 1440 89.8 0.85 37 1450 90.8 0.83 34 0.102 103 63
303) 1465 92.2 0.85 58 1470 92.7 0.82 55 0.225 161 63
37 1475 93.3 0.85 71 1475 93.3 0.82 67 0.34 205 63
55 1475 94.5 0.84 105 1480 94.6 0.82 99 0.49 265 66
75 1475 94.5 0.87 139 1480 95.1 0.86 128 0.88 335 67

3
) Temperature rise class F.
4)
Lower than CENELEC + 1.

Recalculation factors
Recalculation factors for current at rated voltages other than 400 V 50 Hz
Rated voltage at 50 Hz
and motor wound for Recalculation factor

220 V 1.82
230 V 1.74
415 V 0.96
500 V 0.80
660 V 0.61
690 V 0.58

ABB Motors 15
Wärtsilä id: VPENC000053 -
Totally enclosed squirrel cage
three phase motors, aluminium frame
IP 55 IC 411

400 V 50 Hz

Current Torque
Effi- Power IN IS TN TS Tmax
Output Motor type Product code Speed ciency factor
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN

1000 r/min = 6 poles Basic design


0.12 71 073 001- 930 55.4 0.56 0.59 2.5 1.2 2.3 2.7
0.18 71 A 073 002- 920 57.8 0.62 0.75 2.5 1.9 2.0 2.4
0.25 71 B 073 003- 920 62 0.64 0.92 3.0 2.6 2.0 2.4
0.37 80 A 083 001- 920 68 0.66 1.25 3.5 3.8 2.1 2.5
0.55 80 B 083 002- 930 69.8 0.67 1.78 3.5 5.7 2.1 2.5
0.75 90 S 093 001- 930 71.5 0.67 2.36 4.0 7.5 1.9 2.3
1.1 90 L 093 002- 930 74.4 0.69 3.25 4.0 11.0 1.9 2.3
1.5 100 L 103 001- 950 78.2 0.69 4.1 4.5 15.0 1.9 2.3
2.2 112 M 113 001- 940 80.5 0.74 5.4 5.6 22.3 2.1 2.7
3 132 S 133 001- 960 84.5 0.75 6.9 6.1 29.8 2.4 2.6
4 132 MA 133 002- 960 85.5 0.78 8.7 7.1 39.7 2.6 2.8
5.5 132 MB 133 003- 955 86.0 0.78 11.9 6.9 55 2.8 2.8
7.5 160 M 163 101- 970 89.3 0.79 15.4 6.7 74 2.0 2.8
11 160 L 163 102- 970 89.8 0.78 23.0 7.1 109 2.2 2.9
15 180 L 183 101- 970 90.8 0.78 31.0 7.0 148 2.1 3.0
18.5 200 MLA 203 001- 985 91.1 0.81 36 7.0 179 2.5 2.7
22 200 MLB 203 002- 980 91.7 0.81 43 7.2 214 2.5 2.7
30 225 SMB 223 001- 985 92.8 0.83 56 6.6 291 2.5 2.7
37 250 SMA 253 001- 985 93.7 0.83 69 7.3 359 2.8 2.8

2)
1000 r/min = 6 poles High-output design
0.373) 71 C 073 004- 890 63 0.70 1.27 3.0 3.8 1.7 1.9
0.753) 80 C 083 003- 910 71.5 0.70 2.27 3.5 7.5 1.9 2.2
1.31)3) 90 LB 093 003- 910 72.4 0.71 3.85 4.0 13.5 1.9 2.2
2.23) 100 LC 103 002- 940 79 0.71 5.8 4.5 22.0 1.9 2.3
33) 112 MB 113 002- 935 80.0 0.76 7.2 5.5 30.6 2.4 2.7
6.51) 3) 132 MC 133 004- 960 85.0 0.75 14.8 6.6 64.7 2.3 2.7
141)3) 160 LB 163 103- 960 89.1 0.77 29.5 7.6 139 2.7 3.1
18.53) 180 LB 183 102- 965 90.6 0.79 37.5 6.2 183 2.0 2.6
30 200 MLC 203 003- 980 91.7 0.81 56 7.5 292 3.3 3.0
37 225 SMC 223 002- 985 93.2 0.83 69 7.7 359 3.1 3.0
45 250 SMB 253 002- 985 94.1 0.84 82 7.3 436 2.8 2.8
1
) Lower than CENELEC +1.
2
) High-output design
The output of these motors is one step higher than the basic design
with rated outputs in accordance with CENELEC. Motor sizes 112 to 132 are
somewhat longer than the basic design.
3
) Temperature rise class F.

The bullet indicates a 3-letter product code supplement for choice of mounting arrangement
(page 11, pos. 12), voltage and frequency (below) and generation code (page 11, pos. 14).

Code letters for supplementing the product code


Code letter for voltage and frequency
Direct start or, with ∆−connection, also Y/∆-start
Motor S D H E F T U X
size 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz

63-100 220-240 V∆ 380-420 V∆ 440-480 V∆ - 500 V∆ 500 VY 660 V∆1) 690 V∆1) Other rated
380-420 VY 440-480 VY 660-690 VY - voltage,
112-132 220-240 V∆ - 380-420 V∆ 440-480 V∆ 415 V∆ 500 V∆ 660 V∆ 690 V∆ connection
380-420 VY 440-480 VY 660-690 VY - or frequency,
160-250 220, 230 V∆ - 380,400,415V∆ 440 V∆ 415 V∆ 500 V∆ 660 V∆ 690 V∆ 690 V maximum
380,400,415 VY 440 VY 660, 690 VY −
1
) On request.

16 ABB Motors
Wärtsilä id: VPENC000053 -

Insulation class F
Temperature rise class B

380 V 50 Hz 415 V 50 Hz

Moment Weight Sound


Effi- Power Current Effi- Power Current of inertia Foot-mounted pressure level
Output Speed ciency factor IN Speed ciency factor IN J = 1/4 GD2 motor Lp
kW r/min % cos ϕ A r/min % cos ϕ A kgm2 kg dB(A)

1000 r/min = 6 poles Basic design


0.12 920 58.2 0.60 0.56 940 53.5 0.54 0.61 0.0007 5.0 36
0.18 910 59.2 0.66 0.72 930 56.2 0.59 0.77 0.0007 5.5 36
0.25 910 62.6 0.68 0.9 930 61.1 0.61 0.95 0.0009 6.5 36
0.37 910 68.4 0.69 1.22 930 67.3 0.62 1.28 0.0017 8.5 43
0.55 920 69.8 0.72 1.72 930 69.2 0.64 1.78 0.0021 9.5 43
0.75 920 70.6 0.72 2.3 930 70.6 0.64 2.36 0.0032 13 44
1.1 920 73.9 0.73 3.2 930 74.2 0.66 3.25 0.0043 16 44
1.5 940 77.8 0.74 4.1 960 78.4 0.67 4.1 0.0082 23 49
2.2 930 80.0 0.78 5.4 950 80.5 0.71 5.4 0.015 27 54
3 955 84.0 0.77 7.1 965 84.0 0.72 6.9 0.031 39 61
4 955 85.0 0.81 8.9 965 85.5 0.76 8.6 0.038 46 61
5.5 950 85.5 0.81 12.2 960 86.0 0.76 11.8 0.045 54 61
7.5 960 88.7 0.80 16.1 970 89.6 0.77 15.1 0.089 88 59
11 960 89.4 0.80 23.5 970 90.0 0.76 22.4 0.107 102 59
15 970 90.9 0.79 32 975 91.1 0.74 31.0 0.217 151 59
18.5 980 90.8 0.81 38 985 91.1 0.78 36 0.37 165 63
22 980 91.6 0.81 45 985 91.8 0.79 42 0.43 185 63
30 985 92.6 0.83 59 985 92.9 0.82 55 0.64 225 63
37 985 93.5 0.84 72 990 93.8 0.81 67 1.16 280 63

2)
1000 r/min = 6 poles High-output design
0.373) 870 62.5 0.74 1.25 900 62.5 0.66 1.3 0.0012 7.5 36
0.753) 900 71.4 0.74 2.21 920 71.6 0.66 2.3 0.0024 11 43
1.33) 900 71.5 0.75 3.8 920 72.4 0.67 3.8 0.0048 18 44
2.23) 930 77.9 0.75 5.85 940 78.8 0.67 5.9 0.009 26 49
31)3) 925 79.5 0.79 7.3 940 80.0 0.73 7.2 0.018 33 54
6.51) 3) 955 85.0 0.79 14.8 965 84.5 0.71 15.1 0.049 59 61
141)3) 955 88.7 0.79 30.5 965 89.2 0.75 29.2 0.127 117 62
18.53) 965 90.0 0.81 39 965 90.8 0.78 36.5 0.237 160 59
30 980 91.5 0.83 57 985 91.9 0.83 53 0.49 200 63
37 980 93.0 0.83 72 985 93.2 0.81 68 0.75 252 63
45 985 93.8 0.86 85 985 94.2 0.83 80 1.49 320 63
1
) Lower than CENELEC +1.
3
) Temperature rise class F.

Recalculation factors
Recalculation factors for current at rated voltages other than 400 V 50 Hz
Rated voltage at 50 Hz
and motor wound for Recalculation factor

220 V 1.82
230 V 1.74
415 V 0.96
500 V 0.80
660 V 0.61
690 V 0.58

ABB Motors 17
Wärtsilä id: VPENC000053 -
Totally enclosed squirrel cage
three phase motors, aluminium frame
IP 55 IC 411

400 V 50 Hz

Current Torque
Effi- Power IN IS TN TS Tmax
Output Motor type Product code Speed ciency factor
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN

750 r/min = 8 poles Basic design


0.055 63 B 064 002- 650 32.2 0.62 0.44 1.5 0.8 1.6 2.0
0.09 71 A 074 001- 680 43.4 0.63 0.53 2.0 1.3 1.7 2.0
0.12 71 B 074 002- 680 48.6 0.59 0.63 2.0 1.8 1.7 2.0
0.18 80 A 084 001- 700 54.4 0.56 0.90 2.5 2.5 1.8 2.3
0.25 80 B 084 002- 700 58.6 0.55 1.18 2.5 3.4 1.9 2.4
0.37 90 S 094 001- 700 61.5 0.56 1.60 3.0 5.0 1.9 2.4
0.55 90 L 094 002- 700 62.9 0.57 2.35 3.0 7.5 1.9 2.4
0.75 100 LA 104 001- 700 72.9 0.59 2.67 3.5 10.0 2.1 2.7
1.1 100 LB 104 002- 700 74 0.64 3.42 3.5 15.0 2.1 2.7
1.5 112M 114 001- 695 74.5 0.65 4.5 4.1 20.6 1.9 2.4
2.2 132S 134 001- 720 80.5 0.67 5.9 5.3 29.2 1.9 2.5
3 132M 134 002- 720 82.0 0.68 7.8 5.5 39.8 2.4 2.6
4 160 MA 164 101- 715 84.1 0.69 10.0 5.2 54 2.1 2.4
5.5 160 M 164 102- 710 84.7 0.70 13.4 5.4 74 2.4 2.6
7.5 160 L 164 103- 715 86.3 0.70 18.1 5.4 100 2.4 2.8
11 180 L 184 101- 720 88.7 0.76 23.5 5.9 146 2.4 2.6
15 200 MLA 204 001- 740 91.1 0.82 29 7.4 194 1.8 3.0
18.5 225 SMA 224 001- 730 91.1 0.79 37 6.2 242 1.9 2.7
22 225 SMB 224 002- 730 91.5 0.77 45 6.0 288 1.9 2.7
30 250 SMA 254 001- 735 92.8 0.79 59 6.9 390 1.9 2.9

2)
750 r/min = 8 poles High-output design
0.183) 71 C 074 003- 660 51.3 0.64 0.85 2.0 2.5 1.6 1.9
0.373) 80 C 084 003- 680 58.2 0.60 1.60 3.0 5.0 1.7 1.9
0.753) 90 LB 094 003- 680 66.9 0.65 2.6 3.0 10.0 1.8 2.1
1.53) 100 LC 104 003- 700 74 0.66 4.6 3.5 21.0 1.8 2.2
21) 3) 112 MB 114 002- 685 73.5 0.67 5.9 4.4 27.9 1.9 2.2
3.81) 3) 132 MB 134 003- 710 80.5 0.69 9.9 5.2 51.1 2.0 2.3
8.51) 3) 160 LB 164 104- 700 83.5 0.70 21.0 5.1 115 2.4 2.5
153) 180 LB 184 102- 720 88.0 0.76 32.5 6.0 199 2.5 2.6
18.5 200 MLB 204 002- 745 91.4 0.81 36 6.7 237 1.7 2.8
30 225 SMC 224 003- 735 91.8 0.79 60 7.2 390 2.1 3.3
37 250 SMB 254 002- 735 93.2 0.81 71 7.2 481 2.0 2.9
1
) Lower than CENELEC +1.
2
) High-output design
The output of these motors is one step higher than the basic design
with rated outputs in accordance with CENELEC. Motor sizes 112 to 132 are
somewhat longer than the basic design.
3
) Temperature rise class F.

The bullet indicates a 3-letter product code supplement for choice of mounting arrangement
(page 11, pos. 12), voltage and frequency (below) and generation code (page 11, pos. 14).

Code letters for supplementing the product code


Code letter for voltage and frequency
Direct start or, with ∆−connection, also Y/∆-start
Motor S D H E F T U X
size 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz

63-100 220-240 V∆ 380-420 V∆ 440-480 V∆ - 500 V∆ 500 VY 660 V∆1) 690 V∆1) Other rated
380-420 VY 440-480 VY 660-690 VY - voltage,
112-132 220-240 V∆ - 380-420 V∆ 440-480 V∆ 415 V∆ 500 V∆ 660 V∆ 690 V∆ connection
380-420 VY 440-480 VY 660-690 VY - or frequency,
160-250 220, 230 V∆ - 380,400,415V∆ 440 V∆ 415 V∆ 500 V∆ 660 V∆ 690 V∆ 690 V maximum
380,400,415 VY 440 VY 660, 690 VY −
1
) On request.

18 ABB Motors
Wärtsilä id: VPENC000053 -

Insulation class F
Temperature rise class B

380 V 50 Hz 415 V 50 Hz

Moment Weight Sound


Effi- Power Current Effi- Power Current of inertia Foot-mounted pressure level
Output Speed ciency factor IN Speed ciency factor IN J = 1/4 GD2 motor Lp
kW r/min % cos ϕ A r/min % cos ϕ A kgm2 kg dB(A)

750 r/min = 8 poles Basic design


0.055 650 33.6 0.65 0.43 660 30.8 0.61 0.46 0.00028 4.5 32
0.09 670 44.7 0.66 0.50 690 42 0.60 0.55 0.0007 5.5 39
0.12 670 49.9 0.64 0.60 690 47.2 0.57 0.65 0.0009 6.5 39
0.18 690 55.4 0.59 0.85 700 53.5 0.53 0.95 0.0017 8.5 44
0.25 690 60 0.58 1.15 700 57.3 0.51 1.22 0.0021 9.5 44
0.37 690 62.7 0.59 1.57 700 60.5 0.54 1.7 0.0032 13 43
0.55 690 64.9 0.59 2.27 700 61.5 0.55 2.43 0.0043 16 43
0.75 690 72.9 0.61 2.59 700 71.1 0.55 2.78 0.0069 20 46
1.1 700 73.8 0.68 3.38 710 73.1 0.60 3.5 0.0082 23 46
1.5 685 74.0 0.69 4.5 700 74.0 0.62 4.6 0.016 28 52
2.2 715 80.0 0.71 5.9 725 80.0 0.65 5.9 0.038 46 56
3 715 82.0 0.72 7.8 720 82.0 0.66 7.8 0.045 53 56
4 710 83.8 0.71 10.2 720 84.5 0.66 9.9 0.072 75 59
5.5 705 84.0 0.72 13.8 715 85.0 0.68 13.3 0.091 88 59
7.5 710 85.7 0.72 18.6 715 86.6 0.68 17.8 0.131 118 59
11 715 88.2 0.77 24.5 720 89.0 0.75 23.0 0.224 147 59
15 735 91.0 0.83 30 740 91.2 0.79 29 0.45 175 60
18.5 730 91.0 0.79 39 735 91.3 0.76 36 0.61 210 63
22 730 91.4 0.81 45 735 91.5 0.76 44 0.68 225 63
30 735 92.6 0.81 61 740 92.9 0.77 58 1.25 280 63

2)
750 r/min = 8 poles High-output design
0.183) 650 51.4 0.68 0.85 670 50.4 0.61 0.87 0.0012 7.5 39
0.373) 670 59.6 0.64 1.55 690 57.3 0.57 1.65 0.0024 11 44
0.753) 670 66.8 0.69 2.55 690 66.5 0.61 2.65 0.0048 18 43
1.53) 690 73.8 0.70 4.52 700 73.6 0.62 4.7 0.009 26 46
21) 3) 675 73.0 0.71 5.9 690 73.5 0.64 6.0 0.018 33 52
3.81)3) 705 80.0 0.72 10 715 80.5 0.67 9.9 0.049 59 56
8.51)3) 695 81.7 0.73 21.5 705 83.8 0.68 21.0 0.131 118 62
153) 715 87.6 0.78 33.5 720 88.3 0.74 32.0 0.240 155 62
18.5 735 91.2 0.83 37 735 91.6 0.79 35 0.54 200 60
30 730 91.7 0.80 62 735 91.9 0.77 61 0.80 255 63
37 735 92.5 0.82 74 735 93.2 0.81 71 1.52 320 63
1
) Lower than CENELEC +1.
3
) Temperature rise class F.

Recalculation factors
Recalculation factors for current at rated voltages other than 400 V 50 Hz
Rated voltage at 50 Hz
and motor wound for Recalculation factor

220 V 1.82
230 V 1.74
415 V 0.96
500 V 0.80
660 V 0.61
690 V 0.58

ABB Motors 19
Wärtsilä id: VPENC000053 -
Data at voltage ranges
Rated data at voltage codes S and D
Single-speed motors of size 63 to 132 can be produced current that can exist within the voltage range at the
with voltage codes S and D, i.e., voltage range at both rated output. The power factor and speed specified on
50 and 60 Hz. The current rating for each voltage range the rating plate apply at the average voltage within the
is specified on the rating plate. It represents the highest range.

Current in A2) at Speed


r/min Power factor cos ϕ
Output in kW Motor type Product code 380-420 V 440-480 V
50 Hz 60 Hz M2AA 3GAA 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz

3000/3600 r/min = 2 poles Basic design


0.25 0.3 63 B 061 001- 0.75 0.75 2820 3370 0.74 0.75
0.25 0.3 63 B1) 061 002- 0.75 0.75 2820 3370 0.74 0.75
0.37 0.45 71 A 071 001- 1.0 1.0 2840 3410 0.80 0.79
0.55 0.65 71 B 071 002- 1.4 1.4 2850 3410 0.80 0.79

0.75 0.9 80 A 081 001- 1.8 1.8 2860 3440 0.82 0.82
1.1 1.3 80 B 081 002- 2.5 2.5 2870 3450 0.85 0.83

1.5 1.75 90 S 091 001- 3.5 3.5 2870 3460 0.84 0.82
2.2 2.5 90 L 091 002- 4.7 4.7 2870 3470 0.86 0.85
3.0 3.5 100 L 101 001- 6.2 6.2 2900 3470 0.88 0.86

4.0 4.6 112 M 111 001- 7.8 7.7 2850 3450 0.91 0.91
5.5 6.4 132 SA 131 001- 10.9 10.9 2855 3455 0.88 0.88
7.5 8.6 132 SB 131 002- 14.7 14.4 2855 3455 0.90 0.90

3000/3600 r/min = 2 poles High-output design


0.75 0.9 71 C3) 071 003- 1.9 1.9 2820 3410 0.80 0.79
1.5 1.75 80 C3) 081 003- 3.4 3.4 2840 3430 0.84 0.84
2.7 3 90 LB3) 091 003- 5.8 5.8 2860 3470 0.86 0.85
4 4.6 100 LB3) 101 002- 8.3 8.3 2900 3470 0.86 0.85
5.5 6.4 112 MB 111 002- 10. 5 10.4 2855 3455 0.93 0.93
11 12.6 132 SC 131 003- 21 20 2835 3435 0.93 0.93

1500/1800 r/min = 4 poles Basic design


0.18 0.22 63 B 062 001- 0.8 0.8 1370 1660 0.64 0.64
0.18 0.22 63 B1) 062 002- 0.8 0.8 1370 1660 0.64 0.64
0.25 0.30 71 A 072 001- 0.90 0.90 1400 1690 0.67 0.67
0.37 0.45 71 B 072 002- 1.2 1.2 1410 1690 0.70 0.70
0.55 0.65 80 A 082 001- 1.5 1.5 1420 1700 0.74 0.73
0.75 0.90 80 B 082 002- 2.0 2.0 1420 1700 0.74 0.75
1.1 1.30 90 S 092 001- 2.7 2.7 1410 1700 0.79 0.79
1.5 1.75 90 L 092 002- 3.5 3.5 1420 1710 0.79 0.78
2.2 2.5 100 LA 102 001- 5.0 5.0 1430 1720 0.81 0.79
3.0 3.5 100 LB 102 002- 6.6 6.6 1430 1720 0.81 0.79
4.0 4.6 112 M 112 001- 8.9 8.6 1435 1735 0.80 0.81
5.5 6.4 132 S 132 001- 11.5 11.5 1450 1750 0.83 0.83
7.5 8.6 132 M 132 002- 15.3 15.1 1450 1750 0.83 0.83

1500/1800 r/min = 4 poles High-output design


0.55 0.65 71 C3) 072 003- 1.6 1.6 1380 1670 0.73 0.73
1.1 1.3 80 C3) 082 003- 2.8 2.8 1380 1680 0.80 0.80
1.85 2.2 90 L3) 092 003- 4.4 4.4 1400 1690 0.80 0.79
2.2 2.5 90 LB3) 092 004- 5.1 5.1 1390 1690 0.81 0.80
4.0 4.6 100 LC 102 003- 8.9 8.9 1420 1710 0.79 0.78
5.5 6.4 112 MB 112 002- 11.7 11.6 1425 1725 0.83 0.83
11 12.6 132 MB 132 003- 22 22 1450 1750 0.86 0.86

1
) Shaft Ø14 mm, large flange F 130.
2
) Recalculation factors
Multiply by 1.73 when recalculating:
from 380-420 V to 220-240 V 50 Hz
from 440-480 V to 250-280 V 60 Hz
3
) Class F temperature rise

20 ABB Motors
Wärtsilä id: VPENC000053 -
Data at voltage ranges
Rated data at voltage codes S and D
Single-speed motors of size 63 to 132 can be produced current that can exist within the voltage range at the
with voltage codes S and D, i.e., voltage range at both rated output. The power factor and speed specified on
50 and 60 Hz. The current rating for each voltage range the rating plate apply at the average voltage within the
is specified on the rating plate. It represents the highest range.

Current in A1) at Speed


r/min Power factor cos ϕ
Output in kW Motor type Product code 380-420 V 440-480 V
50 Hz 60 Hz M2AA 3GAA 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz

1000/1200 r/min = 6 poles Basic design


0.12 0.15 71 073 001- 0.65 0.65 930 1120 0.58 0.59
0.18 0.22 71 A 073 002- 0.80 0.80 920 1110 0.62 0.62
0.25 0.30 71 B 073 003- 0.95 0.95 920 1110 0.64 0.65
0.37 0.45 80 A 083 001- 1.3 1.3 920 1120 0.66 0.66
0.55 0.65 80 B 083 002- 1.8 1.8 930 1120 0.68 0.64
0.75 0.9 90 S 093 001- 2.4 2.4 930 1120 0.67 0.68
1.1 1.3 90 L 093 002- 3.3 3.3 930 1120 0.69 0.67
1.5 1.75 100 L 103 001- 4.2 4.2 950 1130 0.71 0.69
2.2 2.5 112 M 113 001- 5.4 5.3 940 1140 0.74 0.74
3.0 3.5 132 S 133 001- 7.1 7.0 960 1160 0.75 0.75
4.0 4.6 132 MA 133 002- 8.9 8.9 960 1160 0.78 0.78
5.5 6.4 132 MB 133 003- 12.2 12.2 955 1155 0.78 0.78

1000/1200 r/min = 6 poles High-output design


0.37 0.45 71 C2) 073 004- 1.3 1.3 890 1080 0.70 0.70
0.75 0.9 80 C2) 083 003- 2.3 2.3 910 1100 0.70 0.68
1.3 1.5 90 LB2) 093 003- 3.9 3.9 910 1110 0.71 0.70
2.2 2.5 100 LC2) 103 002- 5.9 5.9 940 1130 0.71 0.69
3.0 3.5 112 MB 113 002- 7.3 7.3 935 1135 0.76 0.75
6.5 7.5 132 MC 133 004- 15.2 14.9 960 1160 0.75 0.76

750/900 r/min = 8 poles Basic design


0.055 0.07 63 B 064 002- 0.5 0.5 650 770 0.62 0.63
0.09 0.11 71 A 074 001- 0.55 0.55 680 780 0.63 0.64
0.12 0.15 71 B 074 002- 0.7 0.7 680 780 0.61 0.62
0.18 0.22 80 A 084 001- 1.0 1.0 700 840 0.56 0.54
0.25 0.30 80 B 084 002- 1.25 1.25 700 840 0.55 0.54
0.37 0.45 90 S 094 001- 1.7 1.7 700 850 0.56 0.56
0.55 0.65 90 L 094 002- 2.5 2.5 700 850 0.57 0.57
0.75 0.9 100 LA 104 001- 2.8 2.8 700 850 0.59 0.60
1.1 1.3 100 LB 104 002- 3.5 3.5 700 850 0.64 0.65
1.5 1.7 112 M 114 001- 4.6 4.4 695 845 0.65 0.65
2.2 2.5 132 S 134 001- 5.9 5.9 720 870 0.67 0.66
3.0 3.5 132 M 134 002- 7.8 7.8 720 870 0.68 0.68

750/900 r/min = 8 poles High-output design


0.18 0.22 71 C2) 074 003- 0.95 0.95 660 780 0.64 0.62
0.37 0.45 80 C2) 084 003- 1.7 1.7 680 820 0.60 0.60
0.75 0.90 90 LB2) 094 003- 2.7 2.7 680 830 0.65 0.65
1.5 1.75 100 LC2) 104 003- 4.8 4.8 700 840 0.66 0.66
2.0 2.3 112 MB 114 002- 6 6 685 835 0.67 0.66
3.8 4.4 132 MB 134 003- 10 10 710 860 0.69 0.69

1
) Recalculation factors.
Multiply by 1.73 when recalculating:
from 380-420 V to 220-240 V 50 Hz
from 440-480 V to 250-280 V 60 Hz
2
) Class F temperature rise

ABB Motors 21
Wärtsilä id: VPENC000053 -
Totally enclosed squirrel cage three phase motors, aluminium frame
IP 55 IC 411 two-speed motors

400 V 50 Hz1)
Current Torque
Moment
Power IN IS TN TS Tmax of inertia
Output Motor type Product code Speed Efficiency factor J=1/4 GD2 Weight
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN kgm2 kg

3000/1500 r/min = 2/4 poles Fan drive, two separate windings


0.37/0.07 71 B 078 202- 2810/1450 64/43 0.90/0.62 1.0/0.4 3.5/2.9 1.2/0.46 1.0/1.1 1.7/2.2 0.0005 6.5
0.65/0.10 80 A 088 201- 2860/1460 68/40 0.86/0.62 1.6/0.6 4.1/2.8 2.1/0.65 1.2/1.1 2.0/2.2 0.0009 9
0.9/0.15 80 B 088 202- 2870/1460 73/45 0.87/0.66 2.1/0.75 4.8/2.8 3.0/1.0 1.5/1.0 2.2/2.3 0.0011 10
1.4/0.22 90 S 098 201- 2870/1470 77/48 0.89/0.63 3.0/1.1 5.3/3.3 4.6/1.4 1.7/1.0 2.4/2.7 0.0019 13
1.9/0.3 90 L 098 202- 2880/1470 78/58 0.89/0.68 4.0/1.1 5.8/3.7 6.3/1.9 1.9/1.0 2.5/2.3 0.0024 16
2.5/0.4 100 L 108 201- 2900/1470 80/60 0.87/0.67 5.2/1.5 6.5/4.1 8.2/2.6 2.1/1.0 3.0/2.7 0.0041 21
3.5/0.6 112 M 118 204- 2895/1470 83.0/68.0 0.92/0.60 6.6/2.1 7.0/5.8 11.5/3.9 1.7/1.8 2.3/2.8 0.012 32
5.5/1.0 132 S 138 207- 2900/1470 84.0/64.0 0.88/0.65 10.8/3.5 7.8/5.7 18.1/6.5 2.4/2.0 2.9/2.8 0.016 42
7.4/1.2 132 M 138 208- 2875/1475 85.0/67.0 0.93/0.64 13.5/4.1 7.5/5.9 24.6/7.8 2.1/2.0 2.6/2.8 0.022 56
13/1.9 160 M 168 352- 2940/1470 88.5/79.5 0.92/0.79 23.0/4.4 7.8/6.4 42/12 2.1/2.1 3.0/2.5 0.054 92
17.5/2.5 160 L 168 353- 2925/1475 89.0/81.0 0.92/0.77 31.0/5.8 7.1/6.7 57/16 2.0/2.5 2.6/2.9 0.057 99
20/2.8 180 M 188 357- 2930/1465 89.0/77.0 0.90/0.77 36.0/6.9 6.4/5.8 65/18 2.1/1.9 2.4/2.0 0.094 132
25/3.6 180 L 188 358- 2940/1465 90.0/78.0 0.88/0.78 46.0/8.6 7.5/7.3 81/24 2.6/1.9 2.9/1.9 0.108 152
30/4.1 200 MLA 208 210- 2945/1480 91.5/85.0 0.89/0.72 54/10 8.0/7.1 97/26 2.2/2.7 2.8/2.8 0.15 175
38/5.5 200 MLB 208 211- 2945/1480 92.5/86.5 0.91/0.74 67/13 7.7/6.8 123/35 2.2/2.6 2.6/2.6 0.19 205
43/6 225 SMB 228 207- 2950/1475 92.5/86.5 0.90/0.78 75/13 7.1/5.8 139/39 2.3/2.7 2.4/2.0 0.26 235
50/7 225 SMC 228 208- 2955/1480 93.0/87.5 0.91/0.78 86/15 7.3/6.1 162/45 2.4/2.9 2.4/2.1 0.29 260
70/10 250 SMB 258 204- 2965/1485 94.0/89.5 0.90/0.76 119/22 9.3/7.1 225/64 2.3/2.5 3.1/2.3 0.57 330

3000/1500 r/min = 2/4 poles Fan drive, Dahlander-connection


0.55/0.11 71 B 078 102- 2800/1440 68/50 0.85/0.62 1.4/0.5 4.0/3.0 1.8/0.73 1.5/1.4 2.0/2.4 0.0005 6.5
0.65/0.13 71 C 078 103- 2800/1440 70/55 0.87/0.62 1.6/0.55 4.1/3.0 2.2/0.86 1.6/1.4 2.1/2.4 0.0006 7.5
0.75/0.15 80 A 088 101- 2850/1460 73/57 0.80/0.57 1.9/0.67 4.5/3.5 2.5/0.98 1.8/1.4 2.4/2.4 0.0009 9
1.1/0.23 80 B 088 102- 2860/1460 76/63 0.83/0.60 2.6/0.88 5.0/3.7 3.8/1.5 1.8/1.3 2.4/2.4 0.0011 10
1.4/0.3 80 C 088 103- 2840/1450 75/67 0.86/0.64 3.1/1.0 5.0/3.7 4.7/2.0 1.8/1.2 2.4/2.5 0.0013 11
1.5/0.33 90 S 098 101- 2860/1460 77/66 0.87/0.67 3.3/1.1 5.2/3.9 5.0/2.1 1.8/1.1 2.4/2.4 0.0019 13
2.2/0.45 90 L 098 102- 2860/1460 80/73 0.88/0.65 4.6/1.4 5.9/4.4 7.3/2.9 2.1/1.2 2.6/2.6 0.0024 16
2.5/0.47 90 LB 098 103- 2860/1460 78/75 0.88/0.62 5.2/1.5 6.1/4.5 8.3/3.1 2.2/1.4 2.7/2.8 0.0027 18
3.0/0.6 100 L 108 101- 2880/1470 81/74 0.89/0.61 6.2/1.9 6.3/4.8 9.9/3.9 2.2/1.4 2.8/2.8 0.0041 21
3.5/0.7 100 LB 108 102- 2880/1470 80/77 0.91/0.65 7.0/2.0 6.2/4.8 12/4.6 2.1/1.2 2.8/3.0 0.005 25
4.5/1 112 M 118 104- 2875/1450 83.0/80.0 0.93/0.76 8.4/2.4 7.0/6.0 14.9/6.6 1.8/1.9 2.3/2.8 0.012 32
6.2/1.3 132 S 138 127- 2880/1455 84.0/80.0 0.91/0.67 11.8/3.5 7.0/6.5 20.6/8.5 2.0/2.6 2.6/3.3 0.016 42
8.3/1.7 132 M 138 108- 2875/1455 84.0/82.0 0.93/0.71 15.4/4.2 7.4/6.6 27.6/11.2 2.5/2.7 2.7/3.3 0.022 56
10/2 160 MA 168 301- 2910/1465 85.0/83.5 0.89/0.73 19.0/4.8 5.9/6.1 30/43 1.5/2.4 2.3/2.8 0.039 73
16/3.2 160 M 168 302- 2915/1465 87.5/86.5 0.92/0.76 28.5/7.0 6.6/6.3 52/21 1.8/2.5 2.4/2.8 0.054 92
19.5/4.5 160 L 168 303- 2930/1465 89.0/88.0 0.89/0.77 36/9.7 7.6/6.4 64/29 2.3/2.5 2.9/2.8 0.057 99
21.5/4.7 180 M 188 305- 2935/1465 90.0/88.0 0.91/0.77 38/10 7.0/5.3 70/28 2.1/2.1 2.6/2.3 0.094 132
26/5.2 180 L 188 306- 2940/1470 90.5/89.5 0.89/0.75 47/11 6.9/5.8 85/34 2.3/2.4 2.6/2.4 0.108 152
32/8 200 MLA 208 110- 2940/1465 90.0/89.0 0.89/0.85 58/16 7.1/6.2 104/52 2.0/2.0 2.5/2.2 0.28 180
39/10 200 MLB 208 111- 2950/1475 91.5/91.0 0.89/0.85 69/19 7.4/6.2 126/65 2.0/2.0 2.6/2.3 0.34 205
42/11 200 MLC 208 112- 2950/1470 92.5/91.0 0.89/0.77 75/23 7.7/5.6 136/71 2.2/2.1 3.0/2.5 0.19 205
45/13 225 SMB 228 107- 2955/1475 93.0/91.5 0.92/0.82 76/25 7.4/5.3 145/84 2.0/2.0 2.6/2.1 0.27 235
55/15 225 SMC 228 108- 2955/1475 93.5/92.5 0.91/0.82 94/29 7.3/5.4 178/97 2.0/2.0 2.6/2.2 0.30 260
75/25 250 SMB 258 104- 2965/1475 94.5/93.0 0.92/0.82 125/48 8.9/5.5 241/162 2.3/2.0 3.1/2.2 0.36 330
1
) Sizes 63 to 100 voltage code H.
Sizes 112 to 250 voltage code D.
The bullet indicates a 3-letter product code supplement for choice of mounting arrangement
(page 11, pos. 12), voltage and frequency (below) and generation code (page 11, pos. 14).

Code letters for supplementing the product code


Code letter for voltage and frequency
Motor size A S B D H E X
1)
63-100 - 220-230 V - 380-400 V 400-415 V 500 V Other rated voltage or
112-132 - 220-230 V - 380-400 V 400-415 V 500 V frequency, 690 V maximum
160-250 220 V 230 V 380 V 400 V 415 V 500 V
1
) Restamping from code H. Note that this results in a certain reduction of output. Rated output on request.

22 ABB Motors
Wärtsilä id: VPENC000053 -
Insulation class F
Temperature rise class F

400 V 50 Hz1)
Current Torque Moment
Power of inertia
IN IS TN TS Tmax
Output Motor type Product code Speed Efficiency factor J=1/4 GD2 Weight
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN kgm2 kg

1500/1000 r/min = 4/6 poles Fan drive, two separate windings


0.30/0.10 71 B 078 205- 1400/950 64/41 0.78/0.66 0.9/0.56 3.3/2.3 2.0/1.1 1.5/1.4 2.0/2.1 0.0009 6.5
0.45/0.15 80 A 088 204- 1400/960 66/46 0.78/0.65 1.3/0.73 3.7/2.6 3.0/1.5 1.7/1.3 2.1/2.2 0.0017 8.5
0.65/0.22 80 B 088 205- 1400/960 70/53 0.82/0.64 1.7/0.94 3.9/2.9 4.4/2.2 1.7/1.4 2.1/2.2 0.0021 9.5
1.0/0.3 90 S 098 204- 1400/940 73/53 0.83/0.75 2.5/1.2 4.2/2.6 6.8/3.0 1.8/1.0 2.2/1.7 0.0032 13
1.5/0.45 90 L 098 205- 1400/940 75/58 0.84/0.73 3.5/1.6 4.3/2.9 10.0/4.5 1.7/1.0 2.1/1.8 0.0043 16
2.0/0.6 100 LA 108 203- 1430/960 77/62 0.85/0.72 4.5/2.0 5.0/3.3 13.0/5.9 1.8/1.0 2.4/1.9 0.0069 20
2.5/0.8 100 LB 108 204- 1430/960 79/68 0.84/0.71 5.5/2.5 5.6/3.5 16.0/7.9 2.0/1.1 2.5/2.0 0.0082 23
3.0/1.0 112 M 118 205- 1445/975 82.0/67.0 0.84/0.68 6.3/3.1 6.0/4.0 19.8/9.8 1.3/1.0 2.3/2.2 0.018 33
4.5/1.5 132 S 138 229- 1460/985 83.0/67.0 0.85/0.64 9.2/5.1 6.5/4.2 29.4/14.5 1.5/1.0 2.3/2.2 0.038 48
6.0/2.0 132 M 138 230- 1460/980 84.0/71.0 0.86/0.73 12.0/5.6 7.1/4.5 39.2/19.5 1.8/1.3 2.5/2.0 0.048 59
10.5/3.5 160 M 168 354- 1460/965 87.0/75.5 0.84/0.78 21/8.6 6.4/4.1 69/35 2.0/1.3 2.5/1.7 0.089 93
14.5/4.5 160 L 168 355- 1460/970 88.5/77.0 0.85/0.76 28/11.0 6.9/4.6 95/44 2.2/1.5 2.6/1.9 0.119 117
16/5 180 M 188 359- 1470/980 89.0/78.0 0.83/0.73 31/12.5 6.3/4.6 104/49 1.9/1.5 2.5/2.0 0.176 131
20/6.5 180 L 188 360- 1470/980 90.0/79.5 0.83/0.74 39/16.0 7.2/5.0 130/63 2.4/1.8 2.7/2.0 0.224 159
23/7.2 200 MLA 208 213- 1475/985 89.5/84.0 0.88/0.87 43/15 7.7/7.8 149/70 1.6/1.9 2.8/2.9 0.44 175
30/9 200 MLB 208 214- 1470/985 90.0/83.5 0.90/0.89 54/18 7.7/7.9 195/87 1.6/1.7 2.7/2.5 0.53 200
34/11 225 SMB 228 209- 1470/985 91.0/85.0 0.91/0.89 60/21 7.7/6.7 221/107 1.5/1.3 2.7/2.3 0.67 225
42/14 225 SMC 228 210- 1475/985 91.5/89.0 0.89/0.89 75/27 8.4/6.8 272/136 1.7/1.4 3.0/2.3 0.78 255
63/18.5 250 SMB 258 205- 1475/985 93.5/87.0 0.89/0.79 110/40 7.5/7.3 408/179 2.4/3.0 2.7/2.6 0.89 335
1
) Sizes 63 to 100 voltage code H.
Sizes 112 to 250 voltage code D.

Recalculation factors
Recalculation factors for current at rated voltages other than 400 V 50 Hz
Motor sizes 63-100 Motor sizes 112-250
Rated voltage at 50 Hz Rated voltage at 50 Hz
and motor wound for Recalculation factor and motor wound for Recalculation factor
1
220 V ) 220 V 1.82
230 V 1.74 230 V 1.74
2
380 V ) 380 V 1.05
415 V 0.96
500 V 0.80 500 V 0.80
660 V 0.61 660 V 0.61
690 V 0.58 690 V 0.58
1 2
) Code S. ) Restamping of code H. Note that this results in a certain reduction of output. Rated output on request.

ABB Motors 23
Wärtsilä id: VPENC000053 -
Totally enclosed squirrel cage three phase motors, aluminium frame
IP 55 IC 411 two-speed motors

400 V 50 Hz1)
Current Torque Moment
Power IN IS TN TS Tmax of inertia
Output Motor type Product code Speed Efficiency factor J=1/4 GD2 Weight
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN kgm2 kg

1500/750 r/min = 4/8 poles Fan drive, two separate windings


0.45/0.07 80 A 088 207- 1380/710 66/34 0.83/0.65 1.3/0.47 3.3/2.0 3.0/0.94 1.3/1.2 1.8/1.8 0.0017 8.5
0.65/0.09 80 B 088 208- 1380/710 69/34 0.84/0.67 1.7/0.56 3.6/2.0 4.4/1.2 1.6/1.0 1.9/1.8 0.0021 9.5
1.0/0.13 90 S 098 207- 1400/700 71/38 0.83/0.70 2.6/0.72 3.9/2.1 6.8/1.8 1.5/1.0 2.0/1.8 0.0032 13
1.4/0.18 90 L 098 208- 1420/710 74/41 0.81/0.62 3.5/1.0 4.5/2.3 9.4/2.4 1.7/1.1 2.3/2.1 0.0043 16
1.85/0.25 100 LA 108 206- 1430/720 78/45 0.84/0.60 4.2/1.4 4.9/2.5 12.0/3.3 1.7/1.1 2.3/2.2 0.0069 20
2.3/0.33 100 LB 108 207- 1430/720 80/49 0.86/0.60 5.0/1.6 5.2/2.6 15.0/4.3 1.8/1.1 2.4/2.2 0.0082 23
3.0/0.4 112 M 118 206- 1440/730 81.0/51.0 0.87/0.58 6.2/2.0 6.8/3.8 19.9/5.2 1.5/1.6 2.4/2.6 0.018 32
4.0/0.6 132 S 138 231- 1465/740 84.0/51.0 0.84/0.53 8.2/3.2 6.5/3.5 26.1/7.7 1.5/1.1 2.4/2.5 0.038 48
5.5/0.9 132 M 138 232- 1455/735 84.0/53.0 0.87/0.64 10.9/3.9 6.2/3.1 36.1/11.7 1.5/1.1 2.2/2.0 0.048 59
9/1.3 160 M 168 356- 1460/735 87.0/60.0 0.84/0.53 18/5.9 6.6/4.0 59/17 2.0/2.2 2.5/2.7 0.089 92
13/1.8 160 L 168 357- 1455/735 88.0/64.0 0.85/0.53 26/8.2 6.0/4.1 89/26 1.9/2.2 2.3/2.6 0.119 117
16/2.3 180 M 188 361- 1475/740 88.5/64.0 0.82/0.53 32/9.7 6.8/4.1 104/30 2.2/2.2 2.7/2.6 0.176 130
19/2.7 180 L 188 362- 1475/740 89.5/68.0 0.83/0.54 37/10.5 7.5/7.2 123/35 2.6/2.6 2.9/2.6 0.224 159
26/3.3 200 MLA 208 216- 1475/740 91.0/73.0 0.85/0.59 49.0/11.0 6.9/4.6 168/46 2.1/2.2 2.5/2.3 0.28 180
30/3.8 200 MLB 208 217- 1470/740 91.5/75.5 0.86/0.59 55.0/12.5 6.7/4.6 195/49 2.1/2.2 2.4/2.2 0.34 205
38/5.2 225 SMB 228 211- 1480/740 91.5/80.5 0.84/0.63 72/15 7.3/5.2 245/67 2.1/2.3 2.6/2.3 0.41 230
46/7 225 SMC 228 212- 1480/740 92.5/82.0 0.86/0.66 85/19 7.7/4.9 297/90 2.3/2.1 2.7/2.1 0.49 265
63/10 250 SMB 258 206- 1475/740 93.5/83.0 0.89/0.65 110/27 7.5/6.0 408/129 2.4/3.0 2.7/2.7 0.89 335

1500/750 r/min = 4/8 poles Fan drive, Dahlander-connection


0.37/0.09 71 B 078 104- 1390/680 65/42 0.73/0.63 1.2/0.49 3.3/2.0 2.5/1.2 1.8/1.4 1.8/1.8 0.0009 6.5
0.45/0.1 71 C 078 105- 1390/690 64/62 0.73/0.59 1.4/0.57 3.4/2.1 3.1/1.4 1.9/1.6 2.3/2.1 0.0012 7.5
0.55/0.11 80 A 088 104- 1380/700 67/48 0.80/0.61 1.6/0.54 3.1/2.3 3.8/1.5 1.5/1.4 1.8/1.8 0.0017 8.5
0.75/0.16 80 B 088 105- 1390/700 71/51 0.80/0.62 2.0/0.70 3.4/2.4 5.1/1.2 1.5/1.2 1.9/1.9 0.0021 9.5
0.9/0.2 80 C 088 106- 1390/700 70/57 0.80/0.62 2.4/0.83 3.6/2.4 6.2/2.8 1.7/1.3 2.1/1.9 0.0024 11
1.1/0.26 90 S 098 104- 1410/700 73/53 0.80/0.63 2.8/1.2 4.2/2.4 7.4/3.6 1.8/1.2 2.3/1.9 0.0032 13
1.5/0.31 90 L 098 105- 1420/710 77/57 0.78/0.54 3.7/1.5 4.8/2.8 10/4.2 2.2/1.7 2.7/2.5 0.0043 16
1.8/0.35 90 LB 098 106- 1410/710 76/60 0.83/0.56 4.2/1.5 4.3/2.7 12/4.8 1.9/1.6 2.3/2.3 0.0048 18
2.2/0.48 100 LA 108 103- 1430/720 79/65 0.82/0.59 5.1/1.8 5.1/3.0 14/6.4 1.9/1.2 2.5/2.1 0.0069 20
2.8/0.6 100 LB 108 104- 1430/720 81/68 0.82/0.58 6.4/2.2 5.2/3.0 18/8.0 2.0/1.2 2.6/2.2 0.0082 23
3.0/0.65 100 LC 108 105- 1430/720 81/67 0.81/0.56 6.8/2.5 5.6/3.0 20/8.7 2.2/1.3 2.8/2.3 0.009 26
3.5/0.7 112 M 118 126- 1430/720 81.0/71.0 0.89/0.58 7.0/2.5 6.8/4.4 23.4/9.3 1.6/1.7 2.5/2.7 0.018 32
5.0/1.0 132 S 138 131- 1450/725 83.0/74.0 0.87/0.59 9.9/3.3 6.4/3.6 32.9/13.2 1.5/1.0 2.3/2.0 0.038 48
6.8/1.4 132 M 138 132- 1460/730 85.0/73.0 0.84/0.55 13.7/5.1 7.6/3.6 44.5/18.3 2.0/1.4 2.8/2.7 0.048 59
10.5/2.2 160 M 168 304- 1460/735 87.5/79.0 0.84/0.54 21/7.4 6.9/3.7 69/29 2.2/1.5 2.7/2.3 0.089 92
15.5/2.7 160 L 168 305- 1460/735 88.5/79.5 0.85/0.51 30/9.5 6.9/3.9 101/35 2.2/1.7 2.6/2.6 0.119 117
17/3.4 180 M 188 307- 1470/730 88.5/78.0 0.85/0.56 33/11 5.8/4.3 111/44 1.7/1.2 2.3/1.9 0.176 130
22/4.4 180 L 188 308- 1475/735 89.5/79.0 0.83/0.53 43/15 6.7/3.9 143/57 2.0/1.7 2.6/2.3 0.224 159
29/6.5 200 MLA 208 116- 1470/730 90.5/86.0 0.86/0.64 54/17 6.9/4.2 188/81 2.2/1.9 2.4/1.9 0.28 180
33/8 200 MLB 208 117- 1475/730 91.5/86.5 0.86/0.64 61/21 7.8/4.2 214/105 2.6/1.9 2.6/1.8 0.34 205
42/10 225 SMB 228 111- 1480/740 92.0/89.5 0.86/0.64 85/27 7.8/5.0 271/129 2.5/2.2 3.0/2.3 0.49 265
50/11 225 SMC 228 112- 1465/735 92.5/89.5 0.87/0.65 91/28 7.3/4.7 324/143 2.3/2.0 2.5/2.0 0.49 265
60/15 250 SMB 258 106- 1475/735 93.0/90.0 0.86/0.70 104/34 7.9/4.7 388/195 2.6/2.1 2.7/2.0 0.89 335
1
) Sizes 63 to 100 voltage code H.
Sizes 112 to 250 voltage code D.

The bullet indicates a 3-letter product code supplement for choice of mounting arrangement
(page 11, pos. 12), voltage and frequency (below) and generation code (page 11, pos. 14).

Code letters for supplementing the product code


Code letter for voltage and frequency
Motor size A S B D H E X

63-100 - 220-230 V - 380-400 V1) 400-415 V 500 V Other rated voltage or


112-132 - 220-230 V - 380-400 V 400-415 V 500 V frequency, 690 V maximum
160-250 220 V 230 V 380 V 400 V 415 V 500 V
1
) Restamping from code H. Note that this results in a certain reduction of output. Rated output on request.

24 ABB Motors
Wärtsilä id: VPENC000053 -
Insulation class F
Temperature rise class F

400 V 50 Hz1)
Current Torque Moment
Power IS TN TS Tmax of inertia
In
Output Motor type Product code Speed Efficiency factor J=1/4 GD2 Weight
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN kgm2 kg

1000/750 r/min = 6/8 poles Fan drive, two separate windings


0.25/0.10 80 A 088 210- 930/700 52/39 0.74/0.67 0.95/0.56 2.6/2.0 2.6/1.3 1.2/1.1 1.8/1.8 0.0017 8.5
0.33/0.14 80 B 088 211- 940/700 57/44 0.71/0.67 1.2/0.70 3.0/2.1 3.3/1.9 1.4/1.1 2.0/1.7 0.0021 9.5

0.45/0.2 90 S 098 210- 940/700 59/44 0.72/0.67 1.6/1.0 3.1/2.2 4.6/2.7 1.4/1.0 2.0/1.7 0.0032 13
0.7/0.3 90 L 098 211- 930/700 63/49 0.75/0.64 2.2/1.5 3.1/2.3 7.2/4.1 1.3/1.1 1.8/1.8 0.0043 16

0.9/0.37 100 LA 108 209- 940/710 69/55 0.79/0.63 2.4/1.55 3.3/2.6 9.2/5.0 1.2/1.1 1.8/1.9 0.0069 20
1.2/0.5 100 LB 108 210- 940/710 73/58 0.75/0.67 3.2/1.9 3.4/2.6 12.0/6.7 1.2/1.1 1.9/1.9 0.0082 23

1.6/0.8 112 M 118 207- 965/720 73.0/57.0 0.70/0.66 4.5/3.1 5.8/4.0 15.8/10.6 2.0/1.6 2.6/2.2 0.018 33
2.6/1.3 132 S 138 213- 975/730 77.0/64.0 0.72/0.64 6.8/4.6 6.5/4.3 25.5/17.0 1.6/1.4 2.8/2.5 0.031 48
3.5/1.6 132 M 138 214- 975/730 79.0/66.0 0.72/0.66 8.9/5.2 7.0/4.9 34.3/20.9 1.8/1.5 3.0/2.5 0.049 59

160 M On request
160 L On request
180 M On request
180 L On request
17/7.5 200 MLB 208 221- 985/740 88.0/81.5 0.85/0.77 33/17 7.1/6.4 165/97 2.2/2.2 2.5/2.5 0.42 185
20/9 200 MLC 208 222- 985/740 88.5/82.5 0.84/0.74 39/21 7.6/7.0 194/116 2.4/2.6 2.7/2.9 0.48 200
26/12 225 SMB 228 215- 985/740 89.5/84.5 0.85/0.76 49/27 7.4/7.1 252/155 2.2/2.4 2.5/2.7 0.63 225
32/14 225 SMC 228 216- 985/740 90.5/85.5 0.83/0.76 62/31 7.0/7.2 310/180 2.4/2.5 2.4/2.5 0.74 250
43/15 250 SMB 258 208- 990/745 91.0/86.0 0.84/0.75 81/34 7.3/7.4 415/198 2.2/2.7 2.5/2.8 1.41 320

1000/500 r/min = 6/12 poles Fan drive, Dahlander-connection


0.28/0.05 80 A 088 107- 920/440 54/31 0.72/0.60 1.1/0.40 2.6/1.7 2.9/1.1 1.3/1.4 1.8/1.8 0.0017 8.5
0.42/0.07 80 B 088 108- 920/440 57/34 0.74/0.57 1.5/0.54 2.7/1.7 4.4/1.5 1.2/1.5 1.7/1.9 0.0021 9.5

0.5/0.08 90 S 098 107- 920/440 60/31 0.74/0.59 1.7/0.63 2.9/1.7 5.2/1.7 1.2/1.5 1.8/2.0 0.0032 13
0.75/0.12 90 L 098 108- 930/450 64/36 0.73/0.54 2.4/0.90 3.0/1.8 7.7/2.5 1.3/1.6 1.9/2.1 0.0043 16

0.9/0.16 100 LA 108 106- 940/470 69/50 0.73/0.49 2.6/0.96 3.6/2.1 9.0/3.2 1.3/1.2 2.0/2.1 0.0069 20
1.3/0.2 100 LB 108 107- 940/470 71/52 0.76/0.47 3.5/1.2 3.4/2.2 13.0/4.0 1.2/1.2 1.8/2.2 0.0082 23
1
) Sizes 63 to 100 voltage code H.
Sizes 112 to 250 voltage code D.

Recalculation factors
Recalculation factors for current at rated voltages other than 400 V 50 Hz
Motor sizes 63-100 Motor sizes 112-250
Rated voltage at 50 Hz Rated voltage at 50 Hz
and motor wound for Recalculation factor and motor wound for Recalculation factor
1
220 V ) 220 V 1.82
230 V 1.74 230 V 1.74
2
380 V ) 380 V 1.05
415 V 0.96
500 V 0.80 500 V 0.80
660 V 0.61 660 V 0.61
690 V 0.58 690 V 0.58
1 2
) Code S. ) Restamping of code H. Note that this results in a certain reduction of output. Rated output on request.

ABB Motors 25
Wärtsilä id: VPENC000053 -
Totally enclosed squirrel cage three phase motors, aluminium frame
IP 55 IC 411 two-speed motors

400 V 50 Hz1)
Current Torque Moment
Power of inertia
IN IS TN TS Tmax
Output Motor type Product code Speed Efficiency factor J=1/4 GD2 Weight
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN kgm2 kg

3000/1500 r/min = 2/4 poles Highest output at both speeds, two separate windings
0.45/0.22 80 A 088 213- 2890/1440 65/55 0.82/0.62 1.25/0.95 3.8/3.0 1.5/1.5 1.1/1.4 2.1/2.4 0.0009 9
0.65/0.33 80 B 088 214- 2880/1440 69/61 0.88/0.68 1.6/1.2 4.2/3.4 2.2/2.2 1.2/1.2 2.1/2.1 0.0011 10
1.1/0.55 90 S 098 213- 2900/1450 74/62 0.87/0.64 2.5/2.0 5.1/3.6 3.6/3.6 1.4/1.5 2.3/2.5 0.0019 13
1.5/0.75 90 L 098 214- 2900/1450 77/70 0.87/0.67 3.3/2.4 5.7/4.1 4.9/4.9 1.5/1.5 2.5/2.5 0.0024 16
2.0/1.0 100 L 108 212- 2890/1450 76/68 0.91/0.75 4.2/2.9 5.8/3.7 6.6/6.6 1.7/1.1 2.5/2.0 0.0041 21
2.6/1.3 112 M 118 201- 2900/1460 80.0/75.0 0.92/0.72 5.1/3.5 6.4/5.0 8.6/8.5 1.6/1.6 2.3/2.3 0.012 32
4.4/2.2 132 SB 138 201- 2925/1450 81.0/74.0 0.86/0.73 9.1/5.9 7.3/4.4 14.4/14.5 2.0/1.3 2.3/2.2 0.016 42
5.6/2.8 132 M 138 202- 2885/1440 82.0/77.0 0.93/0.75 10.6/7.0 6.7/5.0 18.5/18.6 1.8/1.4 2.1/2.2 0.022 56
12/6 160 M 168 359- 2835/1460 87.5/84.5 0.92/0.80 22/13.0 7.7/6.0 39/39 2.1/2.3 2.8/2.4 0.054 92
15/7.5 160 L 168 360- 2940/1460 88.5/84.5 0.93/0.78 27/16.5 7.9/6.0 49/49 2.2/2.4 2.9/2.4 0.057 99
18/9 180 L 188 352- 2945/1460 89.0/84.0 0.90/0.77 32/20 7.7/5.2 58/59 2.5/2.3 2.8/2.1 0.108 152
23/12 200 MLA 208 201- 2960/1475 90.0/89.0 0.89/0.85 42/23 7.8/7.4 74/77 1.7/2.2 2.8/2.5 0.28 178
30/16 200 MLB 208 202- 2960/1475 91.0/90.0 0.90/0.87 53/30 8.2/7.3 97/104 1.8/2.2 2.9/2.5 0.34 204
36/18 225 SMB 228 201- 2960/1480 91.5/91.5 0.91/0.76 63/38 8.0/7.2 116/116 2.5/3.8 2.7/2.5 0.26 236
40/20 225 SMC 228 202- 2960/1475 92.0/91.5 0.91/0.79 69/41 8.5/6.5 129/129 2.8/3.3 2.8/2.2 0.29 261
50/25 250 SMB 258 201- 2965/1485 93.0/93.0 0.91/0.76 86/52 8.9/8.5 161/161 2.1/3.5 2.9/2.9 0.57 333

3000/1500 r/min = 2/4 poles Highest output at both speeds, Dahlander-connection


0.45/0.3 71 B 078 111- 2700/1390 60/61 0.87/0.77 1.3/1.0 3.0/3.2 1.6/2.0 1.6/1.6 1.8/2.0 0.0009 6.5
0.6/0.45 80 A 088 110- 2770/1400 63/66 0.83/0.80 1.7/1.3 3.4/3.4 2.0/3.0 1.6/1.4 2.0/1.9 0.0017 9
0.85/0.65 80 B 088 111- 2770/1400 68/68 0.86/0.84 2.1/1.7 3.8/3.5 2.9/4.4 1.7/1.4 2.1/1.8 0.0021 10
1.3/1.0 90 S 098 110- 2730/1400 71/71 0.88/0.80 3.1/2.6 3.9/3.8 4.5/6.8 2.0/1.5 2.2/2.0 0.0032 13
1.9/1.5 90 L 098 111- 2820/1420 76/75 0.82/0.76 4.4/3.9 5.1/4.4 6.4/10 2.8/2.0 3.0/2.5 0.0043 16
2.5/2.1 100 LA 108 109- 2800/1430 68/76 0.89/0.81 6.0/5.0 4.8/4.4 8.5/14 2.4/1.6 2.7/2.2 0.0069 20
3.1/2.5 100 LB 108 110- 2820/1440 72/79 0.90/0.80 7.0/5.7 5.5/5.1 10/16 2.6/1.8 2.9/2.5 0.0082 23
4/2.6 112 M 118 101- 2865/1430 82.0/77.0 0.94/0.76 7.6/6.5 6.3/6.2 13.3/17.4 1.8/2.3 2.1/2.6 0.012 32
4.7/3.1 132 SB 138 101- 2820/1420 79.0/77.0 0.93/0.76 9.2/7.7 5.5/5.7 15.9/20.8 1.8/2.2 2.1/2.4 0.016 42
7.2/4.8 132 M 138 102- 2870/1435 84.0/81.0 0.93/0.76 13.3/11.5 7.1/6.2 24.0/31.9 2.4/2.5 2.6/2.7 0.022 56
9/6.5 160 MA 168 306- 2885/1440 83.0/82.0 0.92/0.74 17.1/15.6 4.6/4.3 40/43 1.3/1.7 1.9/1.9 0.039 73
12.5/9 160 M 168 307- 2890/1440 85.5/85.5 0.93/0.80 22.5/19 5.2/4.6 41/60 1.4/1.8 1.9/1.9 0.054 92
15/10.5 160 L 168 308- 2900/1445 87.0/86.0 0.93/0.77 27/23 5.8/4.9 49/69 1.6/2.1 2.1/2.1 0.057 99
18/12 180 M 188 301- 2940/1455 89.0/89.0 0.88/0.79 33/25 6.8/5.3 59/79 2.1/2.4 2.6/2.2 0.094 132
24/17 180 L 188 302- 2945/1455 90.0/90.0 0.89/0.80 43/34 7.4/5.2 78/111 2.4/2.4 2.8/2.1 0.108 152
32/24 200 MLA 208 101- 2940/1470 89.0/90.5 0.89/0.86 58/45 6.8/5.9 104/156 1.8/2.1 2.4/2.1 0.28 180
39/29 200 MLB 208 102- 2950/1470 90.5/91.0 0.84/0.86 75/53 6.8/7.0 126/188 1.7/2.2 2.6/2.4 0.34 205
42/32 225 SMB 228 101- 2955/1475 92.5/93.0 0.92/0.88 71/57 7.1/6.5 136/207 1.5/1.9 2.5/2.3 0.49 230
50/40 225 SMC 228 102- 2960/1475 92.5/93.0 0.84/0.87 94/71 7.4/7.1 161/259 1.8/2.0 2.8/2.5 0.49 265
68/50 250 SMB 258 101- 2940/1475 93.0/93.5 0.93/0.88 113/87 6.6/6.9 220/324 1.5/2.1 2.4/2.5 0.89 335
1
) Sizes 63 to 100 voltage code H.
Sizes 112 to 250 voltage code D.

The bullet indicates a 3-letter product code supplement for choice of mounting arrangement
(page 11, pos. 12), voltage and frequency (below) and generation code (page 11, pos. 14).

Code letters for supplementing the product code


Code letter for voltage and frequency
Motor size A S B D H E X
1)
63-100 - 220-230 V - 380-400 V 400-415 V 500 V Other rated voltage or
112-132 - 220-230 V - 380-400 V 400-415 V 500 V frequency, 690 V maximum
160-250 220 V 230 V 380 V 400 V 415 V 500 V
1
) Restamping from code H. Note that this results in a certain reduction of output. Rated output on request.

26 ABB Motors
Wärtsilä id: VPENC000053 -
Insulation class F
Temperature rise class F

400 V 50 Hz1)
Current Torque Moment
Power IN IS TN TS Tmax of inertia
Output Motor type Product code Speed Efficiency factor J=1/4 GD2 Weight
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN kgm2 kg

1500/1000 r/min = 4/6 poles Highest output at both speeds, two separate windings
0.28/0.18 71 B 078 217- 1410/930 57/45 0.75/0.67 1.0/0.90 3.0/2.2 1.8/1.8 1.5/1.3 2.0/1.9 0.0009 6.5
0.35/0.30 80 A 088 216- 1430/930 59/52 0.65/0.69 1.4/1.2 3.5/2.4 2.3/3.0 1.8/1.3 2.4/1.9 0.0017 8.5
0.5/0.37 80 B 088 217- 1430/940 64/59 0.71/0.67 1.6/1.4 3.7/2.8 3.3/3.7 1.8/1.4 2.4/2.0 0.0021 9.5
0.8/0.5 90 S 098 216- 1430/940 68/57 0.80/0.66 2.2/2.0 3.9/2.8 5.3/5.0 1.5/1.4 2.1/2.1 0.0032 13
1.2/0.75 90 L 098 217- 1430/940 73/63 0.81/0.67 3.0/2.6 4.4/3.1 8.0/7.6 1.7/1.5 2.3/2.1 0.0043 16
1.5/0.9 100 LA 108 214- 1440/960 75/69 0.84/0.65 3.5/3.0 4.7/3.8 9.9/8.9 1.5/1.5 2.2/2.4 0.0069 20
1.8/1.1 100 LB 108 215- 1460/960 77/70 0.78/0.64 4.4/3.6 5.8/3.9 11/11 2.1/1.6 3.0/2.5 0.0082 23
2.6/1.7 112 M 118 202- 1445/960 80.0/73.0 0.86/0.76 5.5/4.4 5.9/5.2 17.2/16.9 1.5/1.5 2.2/2.4 0.018 33
3.3/2.2 132 S 138 223- 1470/980 82.0/76.0 0.82/0.65 7.1/6.4 6.8/4.6 21.4/21.4 1.4/1.2 2.5/2.4 0.038 48
4.5/3 132 M 138 224- 1470/980 82.0/77.0 0.85/0.70 9.3/8.0 7.2/5.6 29.2/29.2 1.4/1.5 2.3/2.6 0.048 59
7.5/5.5 160 M 168 361- 1465/965 85.5/80.5 0.83/0.77 15.5/13.0 7.1/4.7 49/54 2.1/1.8 2.7/1.9 0.089 93
11.5/8.5 160 L 168 362- 1465/965 86.5/82.5 0.84/0.76 23.0/19.5 7.0/4.9 75/84 2.1/1.8 2.8/2.0 0.119 117
13/8 180 M 188 353- 1475/975 88.0/82.5 0.82/0.75 26.0/19.0 6.5/4.3 84/78 1.9/1.4 2.6/1.8 0.176 131
15/10 180 L 188 354- 1475/975 88.5/84.0 0.83/0.74 30.0/23.0 7.1/4.4 97/98 2.3/1.5 2.7/1.9 0.224 159
18/12 200 MLA 208 204- 1475/985 88.5/86.0 0.91/0.86 33/24 7.6/7.8 117/116 2.1/2.6 2.5/2.6 0.42 185
22/14.7 200 MLB 208 205- 1480/985 89.5/86.5 0.89/0.87 40/29 8.2/7.6 142/143 2.4/2.6 2.8/2.5 0.48 200
25/16.7 200 MLC 208 206- 1475/980 89.0/85.5 0.87/0.88 47/32 7.7/6.7 162/162 2.3/2.3 2.6/2.2 0.48 200
32/21 225 SMB 228 203- 1480/985 90.0/89.5 0.88/0.86 58/40 8.6/8.0 206/204 2.3/2.4 2.8/2.7 0.63 225
36/24 225 SMC 228 204- 1480/985 90.5/90.0 0.88/0.87 66/45 8.4/7.4 232/233 2.2/2.2 2.8/2.5 0.74 250
50/32 250 SMB 258 202- 1475/985 92.5/90.5 0.89/0.80 89/65 7.5/7.1 324/310 2.3/3.1 2.6/2.6 0.89 335
1
) Sizes 63 to 100 voltage code H.
Sizes 112 to 250 voltage code D.

Recalculation factors
Recalculation factors for current at rated voltages other than 400 V 50 Hz
Motor sizes 63-100 Motor sizes 112-250
Rated voltage at 50 Hz Rated voltage at 50 Hz
and motor wound for Recalculation factor and motor wound for Recalculation factor
1
220 V ) 220 V 1.82
230 V 1.74 230 V 1.74
2
380 V ) 380 V 1.05
415 V 0.96
500 V 0.80 500 V 0.80
660 V 0.61 660 V 0.61
690 V 0.58 690 V 0.58
1 2
) Code S. ) Restamping of code H. Note that this results in a certain reduction of output. Rated output on request.

ABB Motors 27
Wärtsilä id: VPENC000053 -
Totally enclosed squirrel cage three phase motors, aluminium frame
IP 55 IC 411 two-speed motors Insulation class F
Temperature rise class F
400 V 50 Hz1)

Current Torque Moment


Power of inertia
Output Motor type Product code Speed Efficiency factor IN IS TN TS Tmax J=1/4 GD2 Weight
kW M2AA 3GAA r/min % cos ϕ A IN Nm TN TN kgm2 kg

1500/750 r/min = 4/8 poles Highest output at both speeds, two separate windings
0.22/0.11 80 A 088 219- 1420/700 61/45 0.80/0.58 0.7/0.65 3.4/2.2 1.5/1.5 1.2/1.4 2.0/2.2 0.0017 8.5
0.33/0.16 80 B 088 220- 1420/690 63/49 0.83/0.60 0.95/0.80 3.2/2.3 2.2/2.2 1.2/1.3 1.9/2.0 0.0021 9.5
0.5/0.25 90 S 098 219- 1440/690 64/51 0.78/0.65 1.5/1.1 3.6/2.3 3.3/3.4 1.3/1.2 2.2/1.9 0.0032 13
0.7/0.33 90 L 098 220- 1440/690 69/57 0.80/0.61 1.9/1.4 4.2/2.4 4.6/4.6 1.3/1.2 2.2/1.9 0.0043 16
1.0/0.5 100 LA 108 217- 1440/700 71/61 0.86/0.63 2.4/1.95 4.2/2.5 6.6/6.8 1.2/1.1 2.0/1.9 0.0069 20
1.4/0.7 100 LB 108 218- 1440/700 73/62 0.87/0.62 3.2/2.7 4.3/2.6 9.3/9.5 1.2/1.1 2.0/1.9 0.0082 23
1.8/0.9 112 M 118 203- 1470/715 77.0/65.0 0.76/0.66 4.4/3.0 6.5/4.0 11.7/12.0 1.2/1.6 2.2/2.4 0.018 32
2.5/1.3 132 S 138 225- 1470/730 80.0/69.0 0.79/0.58 5.7/4.7 6.7/4.4 16.2/17.0 1.6/1.4 2.6/2.7 0.038 48
3.3/1.7 132 M 138 226- 1470/725 81.0/71.0 0.83/0.67 7.1/5.2 8.0/4.8 21.4/22.4 1.8/1.8 2.7/2.2 0.048 59
5.5/2.7 160 M 168 363- 1465/730 85.0/71.0 0.83/0.57 11.5/9.6 6.8/4.0 36/35 2.1/2.0 2.6/2.3 0.089 92
9/4.5 160 L 168 364- 1465/730 86.5/73.5 0.83/0.56 18/16 7.0/4.1 59/59 2.1/2.1 2.7/2.5 0.119 117
14/7 180 L 188 356- 1475/735 88.0/76.0 0.83/0.56 28/24 7.7/4.2 91/91 2.6/2.3 2.9/2.3 0.225 159
18.5/9.4 200 MLA 208 207- 1475/730 89.5/82.5 0.85/0.65 35/26 7.3/4.3 120/123 2.2/1.9 2.5/1.8 0.28 180
22/11 200 MLB 208 208- 1480/735 90.5/83.0 0.84/0.60 42/32 8.4/4.7 142/143 2.6/2.4 2.9/2.2 0.34 205
28/14 225 SMB 228 205- 1480/735 90.0/85.5 0.85/0.61 53/39 7.7/4.9 181/182 2.1/2.4 2.7/2.2 0.41 230
34/17 225 SMC 228 206- 1480/735 92.0/87.0 0.86/0.66 63/43 7.9/4.8 219/221 2.2/2.2 2.7/2.0 0.49 265
50/25 250 SMB 258 203- 1480/740 92.5/88.0 0.87/0.60 90/68 8.6/6.0 323/323 2.6/3.5 3.0/2.9 0.89 335

1500/750 r/min = 4/8 poles Highest output at both speeds, Dahlander-connection


0.22/0.12 71 B 078 114- 1410/680 61/36 0.73/0.62 0.75/0.80 3.4/1.8 1.4/1.6 1.6/1.5 1.9/1.9 0.0009 6.5
0.4/0.2 80 A 088 113- 1410/700 63/45 0.78/0.60 1.2/1.1 3.1/2.1 2.7/2.7 1.3/1.4 1.9/2.0 0.0017 8.5
0.6/0.28 80 B 088 114- 1410/700 67/50 0.78/0.56 1.7/1.5 3.5/2.2 4.0/3.8 1.5/1.7 2.0/2.2 0.0021 9.5
0.7/0.37 90 S 098 113- 1420/700 72/50 0.80/0.57 1.8/1.9 4.4/2.3 4.7/5.1 1.6/1.6 2.3/2.2 0.0032 13
1.1/0.55 90 L 098 114- 1420/700 73/55 0.84/0.58 2.6/2.6 4.1/2.3 7.4/7.5 1.4/1.5 2.0/2.1 0.0043 16
1.5/0.75 100 LA 108 112- 1440/710 76/62 0.85/0.57 3.4/3.2 4.6/2.8 10.0/10.0 1.4/1.5 2.2/2.2 0.0069 20
2.0/0.95 100 LB 108 113- 1440/710 78/64 0.86/0.55 4.4/4.0 4.8/2.9 13.0/12.0 1.4/1.6 2.2/2.3 0.0082 23
2.5/1.5 112 M 118 103- 1410/705 78.0/67.0 0.90/0.66 5.1/4.9 5.5/4.1 16.9/20.3 1.4/1.5 2.1/2.4 0.018 32
3.8/1.9 132 S 138 125- 1450/730 82.0/70.0 0.86/0.52 7.7/7.6 5.6/3.7 25.0/24.9 1.4/1.3 2.1/2.7 0.038 48
5/2.5 132 M 138 126- 1455/730 85.0/73.0 0.88/0.52 9.6/9.6 6.9/4.8 32.8/32.7 1.7/2.0 2.4/2.8 0.048 59
8/4.5 160 M 168 309- 1440/730 84.5/79.5 0.86/0.60 16/13.5 4.5/3.4 53/59 1.3/1.4 1.8/1.9 0.089 92
12/7 160 L 168 310- 1445/730 86.5/81.0 0.87/0.59 23/21 5.0/3.5 79/92 1.5/1.4 1.9/1.9 0.119 117
16/8 180 L 188 304- 1460/730 88.0/78.5 0.86/0.53 31/28 1.9/3.4 105/104 1.4/1.6 1.9/2.1 0.224 159
22/13 200 MLA 208 107- 1475/735 87.5/86.0 0.81/0.69 45/32 6.5/5.9 142/169 2.0/2.5 2.6/2.7 0.36 165
25/15 200 MLB 208 108- 1475/735 89.0/86.0 0.86/0.67 47/38 7.6/6.0 162/195 2.2/2.6 2.7/2.7 0.42 185
29/17 200 MLC 208 109- 1475/735 90.0/88.0 0.91/0.75 52/38 7.2/6.1 188/221 2.2/2.6 2.4/2.4 0.48 200
35/21 225 SMB 228 105- 1475/735 90.0/89.0 0.90/0.74 63/47 6.7/5.8 227/273 1.7/2.1 2.2/2.3 0.63 225
42/25 225 SMC 228 106- 1475/735 91.0/89.5 0.91/0.75 74/54 6.8/5.9 272/325 1.8/2.1 2.2/2.2 0.74 250
55/33 250 SMB 258 103- 1480/740 92.0/90.5 0.90/0.75 97/71 7.3/6.4 355/426 2.1/2.5 2.5/2.5 1.50 320

1000/750 r/min = 6/8 poles Highest output at both speeds, two separate windings
16/12 200 MLB 208 219- 985/740 86.5/82.5 0.85/0.73 31/29 7.0/6.3 155/155 2.1/2.4 2.4/2.6 0.42 185
18/13.5 200 MLC 208 220- 985/740 87.5/83.5 0.83/0.72 36/32 7.9/6.6 174/174 2.5/2.6 2.8/2.8 0.48 200
23/17 225 SMB 228 213- 985/740 89.0/85.5 0.84/0.78 46/37 7.9/6.3 222/220 2.3/2.2 2.7/2.3 0.63 225
28/20 225 SMC 228 214- 985/740 89.0/86.5 0.86/0.77 57/43 7.1/6.5 272/259 2.0/2.3 2.4/2.4 0.74 250
37/27 250 SMB 258 207- 990/740 90.0/87.5 0.83/0.75 71/59 7.8/6.7 357/348 2.3/2.5 2.7/2.5 1.41 320
1
) Sizes 63 to 100 voltage code H. Sizes 112 to 250 voltage code D.
The bullet indicates a 3-letter product code supplement for choice of mounting arrangement
(page 11, pos. 12), voltage and frequency (below) and generation code (page 11, pos. 14).

Code letters for supplementing the product code


Code letter for voltage and frequency
Motor size A S B D H E X

63-100 - 220-230 V - 380-400 V1) 400-415 V 500 V Other rated voltage or


112-132 - 220-230 V - 380-400 V 400-415 V 500 V frequency, 690 V maximum
160-250 220 V 230 V 380 V 400 V 415 V 500 V
1
) Restamping from code H. Note that this results in a certain reduction of output. Rated output on request.

28 ABB Motors
Wärtsilä id: VPENC000053 -
Motors with other number of poles
Data on these, and on bigger frame size, on request. IP 55 IC 411

Single-speed motors
Speed
No. of poles r/min Motor type M2AA

10 600 90-100
12 500 80-100
14 430 90-100
16 375 90-100
18 330 90-100

Two-speed motors for fan drives


Type of Speed
No. of poles winding r/min Motor type M2AA

4/6 PAM 1500/1000 71-100


6/8 PAM 1000/750 71-100
6/12 Dahlander 1000/500 71-100
8/16 Dahlander 750/375 90-100
2/6 2 windings 3000/1000 71-100
4/12 2 windings 1500/500 80-100
4/16 2 windings 1500/375 90-100
6/12 2 windings 1000/500 80-100
8/12 2 windings 750/500 80-100
8/16 2 windings 750/375 90-100

Two-speed motors with highest output at both speeds


Type of Speed
No. of poles winding r/min Motor type M2AA

4/6 PAM 1500/1000 71-100


6/8 PAM 1000/750 71-100
6/12 Dahlander 1000/500 80-100
2/6 2 windings 3000/1000 71-100
2/8 2 windings 3000/750 71-100
2/12 2 windings 3000/500 80-100
2/16 2 windings 3000/375 90-100
4/12 2 windings 1500/500 80-100

Three-speed motors for fan drives


Type of Speed
No. of poles winding r/min Motor type M2AA

2/4/6 Dahlander + 1 winding 3000/1500/1000 80-100


2/4/8 Dahlander + 1 winding 3000/1500/750 80-100
4/6/8 Dahlander + 1 winding 1500/1000/750 71-100
4/6/12 Dahlander + 1 winding 1500/1000/500 80-100

Three-speed motors with highest output at all speeds


Type of Speed
No. of poles winding r/min Motor type M2AA

2/4/6 Dahlander + 1 winding 3000/1500/1000 90-100


4/6/8 Dahlander + 1 winding 1500/1000/750 90-100

ABB Motors 29
Wärtsilä id: VPENC000053 -

Rating plates
Motor sizes 63 to 100 Motor sizes 112 to 132

Single-speed motors of size 63 to 132 are available current that can exist within the voltage range at the
with voltage codes S and D, i.e., voltage range at both rated output. The power factor and speed specified on
50 and 60 Hz. The current rating for each voltage range the rating plate apply at 400 V 50 Hz and 460 V 60 Hz.
is specified on the rating plate. It represents the highest

Motor sizes 160 to 250

Single-speed motors of size 160 to 250 are available


with voltage codes S and D, i.e., voltage range at both
50 and 60 Hz. The rating plate is arranged in the form
of a table, with values for current, power factor and
motor speed at six voltages.

30 ABB Motors
Wärtsilä id: VPENC000053 -

Variant codes
Code Variant Motor type
1)
M2AA
63-100 112-132 160-180 200-250
Balancing
052 Balancing to grade R (IEC 34-14). T T T T
417 Balancing to grade S (IEC 34-14). – T T R
423 Balancing without key R R R R
424 Balancing with full key T T T T
Bearings and lubrication
036 Transport lock for bearings. – L L L
037 Roller bearing at D-end – – L L
Transport lock included.
039 Cold resistant grease. L L L L
For bearing temperatures -55 - +100 °C.
040 Heat resistant grease. S L L L
For bearing temperatures -25 - +150 °C.
Mandatory for ambient temperatures >50 °C.
041 Bearings regreasable via grease nipples. – L L S
042 Internal bearing cover, locked D-end. L L S L
Standard for sizes 90 and 100
Standard for sizes 112 and 132, flanged versions.
043 SPM nipples. – L L L
057 2RS bearings at both ends. L L L L
Grease for bearing temperatures -20 - +110°C
058 Angular contact ball bearing at D-end, R L L –
shaft force away from bearing.
Transport lock included.
059 Angular contact ball bearing at N-end, R L L L
shaft force towards bearing.
Transport lock included.
060 Angular contact ball bearing at D-end, R – – –
shaft force towards bearing.
061 Angular contact ball bearing at N-end. – – – L
Shaft force away from bearing.
Transport lock included.
188 Larger bearing than standard. – L S S
Larger bearing at D-end, 63 series.
Sizes 90 and 100 have 63 series bearings as standard.
Brake
196 Built-on brake, standard motor. R2) L2) – –
Externally mounted brake with automatic adjustment of brake air gap.
197 Built on brake, type BXLF, standard motor. R2) L2) – –
Externally mounted brake with automatic adjustment of brake air gap.
Branch standard designs
071 Cooling Tower duty. T T T T
Only motors with shaft extensions downwards.
079 Silumin-alloy rotor cage. T T T T
142 ”Manilla" winding connection. (440 V∆ series, 220 V∆ parallel, 60Hz) T T T T
Single speed motors only.
170 Smoke venting specification 200 °C, 2 h. T T T T
171 Smoke venting specification 200 °C, 0.5 h. T T T T
172 Smoke venting specification 200 °C, 1 h. – R R R
178 Stainless steel/acid proof bolts. L L L L
199 Extreme heavy duty design. – L T T
Basic version supplemented with:
External screws are stainless/acid resistant,
sizes 112 and 132 only in the terminal box.
63 series ball bearings at both ends, sizes 112 and 132 only at D-end.
Stainless steel rating plate.
Sizes 200-250, special terminal box. Sizes 160 and 180: grease nipples.
209 Non-standard voltage or frequency (special winding). T T T T
416 High speed design. R R R R
425 Corrosion protected stator and rotor core. L T T T
Cooling system
053 Metal fan cover. L L S S
The dimension L1 and L2 respectively is increased by 7.5 mm
for the frame size 112 and 5.5 mm for the frame size 122.
068 Aluminium fan. L L L L
Mandatory for ambient temperatures:
For sizes 62-100, ≥80 °C, For sizes 112-250, > 50 °C.
075 Cooling method IC418 (without fan). L R R R
183 Separate motor cooling (fan axial, N-end) R L L L
1
) Certain variant codes cannot be used simultaneously. S Included as standard.
2
) From SEMOT stock. L On modification of a stocked motor, or on new manufacture, the number per order may be limited.
T New manufacture only.
R On request.
ABB Motors 31
Wärtsilä id: VPENC000053 -
Code Variant Motor type
1)
M2AA
63-100 112-132 160-180 200-250

Dimension drawing
141 Binding dimension drawing L L L L
Drain holes
065 Plugged drain holes. – L L L
066 Modified drain hole position. IP 54 for sizes 63-100. L L L L
Specify IM designation.
076 Drain holes with plugs. L – – –
Holes are sealed with a felt plug. Corrosion protected rotor. IP 55.
IM designation must be stated.
Earthing bolt
067 External earthing bolt. L L L L
Earthing screw for connection of external protective earth.
Hazardous environments
See catalogue ”Motors for Hazardous Environments EEx d,
EEx de, EEx e, Ex nA, BA/Ex-motors GB 99-03”, for details.
Heating elements
Motor size Element capacity
62-71 8W
80-160 25 W
180-250 50 W
450 Heating element 100-120 V. L L L L
451 Heating element 200-240 V. L L L L
High Performance Motors
See catalogue ”High Performance Motors, BA/High
Performance GB 98-01”, for details.
Insulation systems
014 Winding insulation class H. T T T T
405 Special winding insulation for frequency converter supply R T T T
rated voltage >500 V.
406 Winding for supply >690 ≤1000 V. – R R R
Marine Motors
See catalogue ”Marine Motors, BA/Marine GB 98-05”, for details.
Mounting arrangements
007 IM 3001 flange mounted, IEC flange, from IM 1001 (B5 from B3). – – – L
Large flange with clearance holes.
008 IM 3101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). L L – –
Small flange with tapped holes.
009 IM 3001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). L L L L
Large flange with clearance holes.
047 IM 3601 flange mounted, IEC flange, from IM 2001 (B14 from B5),
flange mounted motor with large flange. L L – –
Small flange with tapped holes.
048 IM 3001 flange mounted, IEC flange, from IM 3601 (B5 from B14),
flange mounted motor with small flange. L – – –
Large flange with clearance holes.
078 (IM 3601) Flange mounted, DIN C-flange. L – – –
Small flange with tapped holes.
Larger flange than standard version.
080 (IM 3001) Flange mounted, DIN A-flange, L – – –
Large flange with clearance holes.
Larger flange than standard version.
090 (IM 2101) foot/flange mounted, DIN C-flange,
from IM 1001 (B34 from B3). L – – –
Small flange with tapped holes.
Larger flange than standard version.
091 (IM 2001) foot/flange mounted, DIN A-flange,
from IM 1001 (B35 from B3). L – – –
Large flange with clearance holes.
Larger flange than standard version.
Painting
114 Special paint colour, standard grade. L L L L
179 Special paint specification. R R R R

1
) Certain variant codes cannot be used simultaneously. S Included as standard.
L On modification of a stocked motor, or on new manufacture, the number per order may be limited.
T New manufacture only.
R On request

32 ABB Motors
Wärtsilä id: VPENC000053 -
Code Variant Motor type
1)
M2AA
63-100 112-132 160-180 200-250

Protection
005 Protective roof, vertical motor, shaft down. L L L L
Vertically mounted motors with shaft extension downwards.
073 Radial seal at D-end. T L L L
Only flange mounted motors for sizes 63-100.
158 Degree of protection IP65. L R R R
403 Degree of protection IP 56.
Dust proof version. Water from waves which – L L L
splash over must not enter in serious quantities.
784 Gamma-seal at D-end. L R R R
Rating and instruction plates
002 Restamping voltage, frequency, and output. Continuous duty. L L L L
All data to be specified in the order.
003 Individual serial number. L L L L
013 Restamping to output for class F temperature rise. L R R R
Applies to variants with temperature rise to class B as standard.
095 Restamping of output. Maintained voltage and frequency. Intermittent duty. L L L L
All data to be specified in order.
098 Stainless rating plate. L L L L
138 Mounting of additional identification plate. L L L L
139 Additional indentification plate delivered loose. L L L L
160 Additional rating plate affixed. – R R R
161 Additional rating plate delivered loose. L L L L
198 Aluminium rating plate. L R S S
Shaft and rotor
069 Two shaft extensions as per basic catalogue. T T T T
Standard shaft material.
070 One or two special shaft extensions, standard shaft material. T T T T
165 Shaft extension with open key-way. T T T T
410 Stainless/acid-proof steel shaft, standard or non-standard design. T T T T
One or two shaft extensions.
Standards and regulations
010 Fulfilling CSA requirements. T L L L
029 Fulfilling Underwriters Laboratory (UL) requirements. T – – –
770 Motor designed to comply with IEC 34-1 standard R R R R
but with S.F. = 1.2 (service factor).
Stator winding temperature sensors
Breaking capacity for bimetal detector:
Size 63-100
2 A at 280 V vs
5 A at 240 V vs
2.5 A at 24 V ls
Size 112-250
4 A at 250 V vs
2 A at 60 V ls
121 Bimetal detectors, break type (NCC), L L2) L2) L2)
(3 in series), 130°C, in stator winding.
2 in series for 71-100. Size 63, new manufacture only.
122 Bimetal detectors, break type (NCC), L L2) L2) L2)
(3 in series), 150 °C, in stator winding.
2 in series for 71-100. Size 63, new manufacture only.
123 Bimetal detectors, break type (NCC), L L2) L2) L2)
(3 in series), 170 °C, in stator winding.
2 in series for 71-100. Size 63, new manufacture only.
125 Bimetal detectors, break type (NCC), L L2) L2) L2)
(2x3 in series), 150 °C, in stator winding.
2 x 2 in series for 71-100. Size 63, new manufacture only.
127 Bimetal detectors, break type (NCC), L L2) L2) L2)
(3 in series, 130 °C & 3 in series , 150 °C), in stator winding.
2 x 2 in series for 71-100. Size 63, new manufacture only.
321 Bimetal detectors, closing type (NO), R R R R
(3 in parallel), 130°C, in stator winding.
322 Bimetal detectors, closing type (NO), L R R R
(3 in parallel), 150°C, in stator winding.
325 Bimetal detectors, closing type (NO), R R R R
(2x3 in parallel), 150°C, in stator winding.
327 Bimetal detectors, closing type (NO), R R R R
(3 in parallel, 130°C, & 3 in parallel, 150°C), in stator winding.

1
) Certain variant codes cannot be used simultaneously. S Included as standard.
2
) Two speed motors, new manufacture only. L On modification of a stocked motor, or on new manufacture, the number per order may be limited.
T New manufacture only.
R On request.
ABB Motors 33
Wärtsilä id: VPENC000053 -
Code Variant Motor type
1)
M2AA
63-100 112-132 160-180 200-250

435 PTC - thermistors L L2) L2) L2)


(3 in series), 130 °C, 3 in stator winding.
Two speed motors and size 63, only for new manufacture.
Tripping device, more information from ABB Control.
436 PTC thermistors. L L2) L2) S
150 °C, 3 in series.
Two speed motors and size 63, only for new manufacture.
Tripping device, more information from ABB Control.
437 PTC - thermistors L L2) L2) L2)
(3 in series), 170 °C, in stator winding.
Two speed motors and size 63, only for new manufacture.
Tripping device, more information from ABB Control.
439 PTC - thermistors L L2) L2) L2)
(2x3 in series), 150 °C, in stator winding.
Two speed motors and size 63, only for new manufacture.
Tripping device, more information from ABB Control.
440 PTC - thermistors L R R R
(3 in series, 110 °C, & 3 in series, 130 °C), in stator winding.
Two speed motors and size 63, only for new manufacture.
Tripping device, more information from ABB Control.
441 PTC - thermistors L L2) L2) L2)
(3 in series, 130 °C, & 3 in series, 150 °C), in stator winding.
Two speed motors and size 63, only for new manufacture.
Tripping device, more information from ABB Control.
442 PTC - thermistors L L2) L2) L2)
(3 in series, 150 °C & 3 in series , 170 °C), in stator winding.
Two speed motors and size 63, only for new manufacture.
Tripping device, more information from ABB Control.
445 PT100 – L2) L2) L2)
(1 per phase) in stator winding. Measurement current max. 10 mA.
Temperature: 0 10 20 50 100 150°C
Resistance: 100 103.9 107.7 119.3 128.5 158 Ohm
Monitoring unit, more information from ABB Network Partner.
446 PT100 – – L2) L2)
(2 per phase) in stator winding. Measurement current max. 10 mA.
Temperature: 0 10 20 50 100 150°C
Resistance: 100 103.9 107.7 119.3 128.5 158 Ohm
Monitoring unit, more information from ABB Network Partner.
Terminal box
015 Ð connection in terminal box, (reconnection from Y.) L S S S
Single speed motors only.
017 Y connection in terminal box (reconnection from Ð.) L S S S
Single speed motors only.
018 Ð connection in terminal box (reconnection from Y.) L R R R
Single phase Steinmetz.
019 Larger than standard terminal box. R 3) – L L
Standard for 200-250, voltage code S.
021 Terminal box on left-hand side, seen from D-end. – – – T
112 Mounting of plug-in contact. L3) R – –
180 Terminal box on right-hand side, seen from D-end. – – – T
136 Extended cable connection, standard terminal box. L R R R
2 m long connection cable.
137 Extended cable connection, low terminal box. T T T T
Sizes 63-100: terminal box without screw terminals,
2 m long connection cable.
Sizes 112-250: 2 m long flying leads.
187 Cable glands of non-standard design. R R R R
230 One standard cable gland. L L L L
402 Terminal box adapted for Al cables. – – – T
418 Separate terminal box for temperature detectors. R T L L
467 Lower than standard terminal box and rubber extended cable. – L L T
Terminal box without screw terminals and extended rubber
connection cable, 2 m.
M2AA 112-180 have standard terminal box with low, flat cover.
731 Two standard cable glands. L L L L

1
) Certain variant codes cannot be used simultaneously. S Included as standard.
2
) Two speed motors, new manufacture only. L On modification of a stocked motor, or on new manufacture, the number per order may be limited.
3
) Only for frame size 80-100. T New manufacture only.
R On request.

34 ABB Motors
Wärtsilä id: VPENC000053 -
Code Variant Motor type
1)
M2AA
63-100 112-132 160-180 200-250

Testing
140 Test confirmation. L L L L
145 Type test report from test of identical motor. R L L L
400 V 50 Hz.
146 Type test with report for motor from specific delivery batch. T L L L
147 Type test report with motor from specific delivery batch, T L L L
customer witnessed.
148 Routine test report. R L L L
149 Test according to separate test specification. R L L L
221 Type test and multi-point load test with report for motor T R R R
from specific delivery batch.
222 Torque/speed curve, type test and multi-point load test with report T R R R
from specific delivery batch.
498 Test report fulfilling SGS requirements. L – – –
760 Vibration level test. R R R R
762 Noise level test. L R R R
764 Complete test with ABB frequency converter. R R R R
Variable speed drives
For long cables, see code 405 ”Insulation systems”.
182 Pulse sensor mounted as specified. R R R R
470 Prepared for hollow shaft pulse tacho. T T T L
(Leine & Linde equivalent).
472 1024 of pulse tacho. T T T T
(Leine & Linde equivalent).
Hollow shaft version.
473 2048 of pulse tacho. T T T L
(Leine & Linde equivalent).
Hollow shaft version.
474 Separate motor cooling and prepared for – R R T
hollow shaft pulse tacho (Leine & Linde equivalent).
476 Separate motor cooling (fan axial, N-end) – R R T
and 1024 pulse tacho (Leine & Linde equivalent).
477 Separate motor cooling (fan axial, N-end) – R R T
and 2048 pulse tacho (Leine & Linde equivalent).
700 Insulated bearing assembly. – R R R
Y/D starting
117 Terminals for Y/∆ start – – T R
at both speeds
(two speed motors with separate windings).
118 Terminals for Y/∆ start – T T –
at high speed
(two speed motors with separate windings).

1
) Certain variant codes cannot be used simultaneously. S Included as standard.
2
) Two speed motors, new manufacture only. L On modification of a stocked motor, or on new manufacture, the number per order may be limited.
T New manufacture only.
R On request.

ABB Motors 35
Wärtsilä id: VPENC000053 -

Dimension drawings
M2AA 63-100
Basic design and high-output design
Foot-mounted motor IM 1081, IM 1082, IM B 3 Flange-mounted motor, large flange
IM 3081, IM 3082, IM B 5

Flange-mounted motor, small flange


IM 3681, IM 3682, IM B 14

IM 1081, IM 1082, IM B 3

Type
M2AA A1) AA AB AC AE B1) BA BB C1) CA CB D1) DA1) DB DC E2) EA EG EH F1)

632) 100 16 120 120 85 80 14 98 40 68 9 14 11 M5 M4 30 23 12.5 10 5


71 112 20 136 140 85 90 21 112 45 80 11 14 11 M5 M4 30 23 12.5 10 5
80 125 25 154 158 97 100 20 125 50 87 12.5 19 14 M8 M5 40 30 19 12.5 6
90 S 140 27 170 178 97 100 30 125 56 94 12.5 24 14 M8 M5 50 30 19 12.5 8
90 L 140 27 170 178 97 125 30 150 56 94 12.5 24 14 M8 M5 50 30 19 12.5 8
100 L 160 32 197 198 97 140 34 172 63 100 16 28 19 M10 M8 60 40 22 19 8

Type
M2AA FA1) G GA GB GC H1) HA HC HD HE K KA L LC UB VA VB VC VD

632) - 11 16 9.5 - 63 7 123 150 50.5 7 10 213 241 Pr 18.6, Pg 11 31 92 30.5 61.5
71 - 11 16 9.5 - 71 9 141 172 62.5 7 11 239 268 Pr 22.5, Pg 16 34 92 30.5 61.5
80 5 15.5 21.5 11 16 80 10 159 192 68.5 10 14 272 307 Pr 22.5, Pg 16 37.5 100 33 67
90 S 5 20 27 11 16 90 10 179 212 79.5 10 14 295 330 Pr 22.5, Pg 16 43.5 100 33 67
90 L 5 20 27 11 16 90 10 179 212 79.5 10 14 320 355 Pr 22.5, Pg 16 43.5 100 33 67
100 L 6 24 31 15.5 21.5 100 12 199 236 93.5 12 14 358.5 403 Pr 22.5, Pg 16 47 100 33 67

IM 3081, IM 3082, IM B 5 IM 3681, IM 3682, IM B 14

Type Type
M2AA HB LA M N P S T M2AA HB LA M N P S T
2)
63 2)
87 9 115 95 140 10 3 63 87 8 75 60 90 M5 2.5
63 87 9 130 110 160 10 3.5 71 101 10 85 70 105 M6 2.5
71 101 9 130 110 160 10 3.5 80 112 10 100 80 120 M6 3
80 112 10 165 130 200 12 3.5
90 S 122 14 115 95 140 M8 3
90 S 122 10 165 130 200 12 3.5 90 L 122 14 115 95 140 M8 3
90 L 122 10 165 130 200 12 3.5 100 L 136 16 130 110 160 M8 3.5
100 L 136 11 215 180 250 15 4
2
1
) Tolerances ) M2AA 63 can be supplied with shaft extension D = 11,
A, B ISO js14 E = 23, F = 4 and GA = 12.5 mm, and DB = M4,
D, DA ISO j6 if B5 flange M = 115 mm.
3
F, FA ISO h9 ) Alternative version of additional shaft extension for
H +0 -0.5 M2AA 63 and M2AA 71.
N ISO j6
C, CA ±0.8

36 ABB Motors
Wärtsilä id: VPENC000053 -
M2AA 63-100
Basic and high output design
Foot- and flange-mounted motor Foot- and flange-mounted motor
IM 2081, IM 2082, IM B 35, large flange IM 2181, IM 2182, IM B 34, small flange

IM 2081, IM 2082, IM B 35, IM 2181, IM 2182, IM B 34

Type
M2AA A1) AA AB AC AE B1) BA BB C1) CA CB D1) DA1) DB DC E2) EA EG EH F1)
2)
63 100 16 120 120 85 80 14 98 40 68 9 14 11 M5 M4 30 23 12.5 10 5
71 112 20 136 140 85 90 21 112 45 80 11 14 11 M5 M4 30 23 12.5 10 5
80 125 25 154 158 97 100 20 125 50 87 12.5 19 14 M8 M5 40 30 19 12.5 6
90 S 140 27 170 178 97 100 30 125 56 94 12.5 24 14 M8 M5 50 30 19 12.5 8
90 L 140 27 170 178 97 125 30 150 56 94 12.5 24 14 M8 M5 50 30 19 12.5 8
100 L 160 32 197 198 97 140 34 172 63 100 16 28 19 M10 M8 60 40 22 19 8

Type
M2AA FA1) G GA GB GC H1) HA HC HD HE K KA L LC UB VA VB VC VD

632) - 11 16 9.5 - 63 7 123 150 50.5 7 10 213 241 Pr 18.6, Pg 11 31 92 30.5 61.5
71 - 11 16 9.5 - 71 9 141 172 62.5 7 11 239 268 Pr 22.5, Pg 16 34 92 30.5 61.5
80 5 15.5 21.5 11 16 80 10 159 192 68.5 10 14 272 307 Pr 22.5, Pg 16 37.5 100 33 67
90 S 5 20 27 11 16 90 10 179 212 79.5 10 14 295 330 Pr 22.5, Pg 16 43.5 100 33 67
90 L 5 20 27 11 16 90 10 179 212 79.5 10 14 320 355 Pr 22.5, Pg 16 43.5 100 33 67
100 L 6 24 31 15.5 21.5 100 12 199 236 93.5 12 15 358,5 403 Pr 22.5, Pg 16 47 100 33 67

IM 2081, IM 2082, IM B 35 IM 2181, IM 2182, IM B 34

Type Type
M2AA HB LA M N P S T M2AA HB LA M N P S T

632) 87 9 115 95 140 10 3 632) 87 8 75 60 90 M5 2.5


63 87 9 130 110 160 10 3.5 71 101 10 85 70 105 M6 2.5
71 101 9 130 110 160 10 3.5 80 112 10 100 80 120 M6 3
80 112 10 165 130 200 12 3.5
90 S 122 14 115 95 140 M8 3
90 S 122 10 165 130 200 12 3.5 90 L 122 14 115 95 140 M8 3
90 L 122 10 165 130 200 12 3.5 100 L 136 16 130 110 160 M8 3.5
100 L 136 11 215 180 250 15 4
1
) Tolerances 2
) M2AA 63 can be supplied with shaft extension D = 11,
A, B ISO js14 E = 23, F = 4 and GA = 12.5 mm, and DB = M4,
D, DA ISO j6 if B5 flange M = 115 mm.
F, FA ISO h9 3
) Alternative version of additional shaft extension for
H +0 -0.5 M2AA 63 and M2AA 71.
N ISO j6
C, CA ±0.8

ABB Motors 37
Wärtsilä id: VPENC000053 -
M2AA 63-100
Special design with DIN flange
Basic design and high-output design

Flange-mounted (IM 3081, IM B 5) and foot- DIN A-flange. Large flange with clearance holes.
and flange-mounted motor (IM 2081, IM B 35), Larger than large flange of basic design.
respectively. See variant codes 080 and 091, respectively.

Type Flange designation Flange dimensions


M2AA IEC DIN LA M N P S T
1)
63 FF 115 A 140 9 115 95 140 9 3
71 FF 165 A 200 10 165 130 200 12 3.5
80 FF 215 A 250 11 215 180 250 15 4
90 S FF 215 A 250 11 215 180 250 15 4
90 L FF 215 A 250 11 215 180 250 15 4
100 L FF 265 A 300 12 265 230 300 15 4
1
) Smaller than corresponding IEC flange.

Flange-mounted (IM 3081, IM B 5) and foot- DIN A-flange. Large flange with clearance holes.
and flange-mounted motor (IM 2081, IM B 35), Smaller than large flange of basic design.
respectively. Only available on request.

Type Flange designation Flange dimensions


M2AA IEC DIN LA M N P S T

71 FF 115 A 140 9 115 95 140 10 3


80 FF 130 A 160 9 130 110 160 10 3.5
90 S FF 130 A 160 9 130 110 160 10 3.5
90 L FF 130 A 160 9 130 110 160 10 3.5
100 L FF 165 A 200 10 165 130 200 12 3.5

Note: Dimensions C, L and LC are 15 mm longer than in the standard version.

Flange-mounted (IM 3681, IM B 14) and DIN C-flange. Large flange with tapped holes.
foot- and flange-mounted motor Larger than small flange of basic design.
(IM 2181, IM B 34), respectively. See variant codes 078 and 090, respectively.

Type Flange designation Flange dimensions


M2AA IEC DIN LA M N P S T

71 FT 115 C 140 12 115 95 140 M8 3


80 FT 130 C 160 12 130 110 160 M8 3.5
90 S FT 130 C 160 15 130 110 160 M8 3.5
90 L FT 130 C 160 15 130 110 160 M8 3.5
100 L FT 165 C 200 15 165 130 200 M10 3.5

38 ABB Motors
Wärtsilä id: VPENC000053 -
M2AA 112, 132
Basic design
Foot-mounted motor IM 1001, IM 1002, IM B 3 Flange-mounted motor, large flange
IM 3001, IM 3002, IM B 5

Flange-mounted motor, small flange


IM 3601, IM 3602, IM B 14

IM 1001, IM B 3

Type
M2AA A1) AA AB AC AE B1) B' BA BB BC C1) CA' 1) 4) CA1) 5) CB D1) DA1) DB DC E2) EA EG EH F1) FA1) G

112 M 190 41 222 221 160 140 - 31 168 31 70 111.5 138 14 28 19 M10 M8 60 40 22 19 8 6 24
132 S 216 47 262 261 160 140 1788) 40 212 76 89 158 191 18 38 24 M12 M8 80 50 28 19 10 8 33
132 M 216 47 262 261 160 1408) 178 40 212 76 89 120 153 18 38 24 M12 M8 80 50 28 19 10 8 33

Type
M2AA GA GB GC H1) HA HC HD HE K L14) L25) LC14) LC25) UB13) UB23) VA VB VC6) VD17) VD27)

112 M 31 15.5 21.5 112 12 226 258 92 12 361 388 421.5 448 Pr 22.5, Pg 16 Pr 28.3, Pg 21 60 160 80 120 40
132 S 41 20 27 132 14 263.5 295.5 109.5 12 447 447 517 517 Pr 22.5, Pg 16 Pr 28.3, Pg 21 71 160 80 120 40
132 M 41 20 27 132 14 263.5 295.5 109.5 12 447 481.5 517 550 Pr 22.5, Pg 16 Pr 28.3, Pg 21 71 160 80 120 40

IM 3001, IM B 5 IM 3601, IM B 14

Type Type
M2AA HB LA M N1) P S T M2AA HB LA M N1) P S T

112 146 11 215 180 250 14.5 4 112 146 20 130 110 160 M8 3.5
132 163.5 14 265 230 300 14.5 4 132 163.5 18 165 130 200 M10 3.5
1
) Tolerances 2
) Shoulder of shaft extension and contact surface of flange are in the same plane.
A, B ISO js14 3
) Knockout openings
C, CA +0 -2 4
) Single-speed motors and two-speed motors 132 S.
D28 ISO j6 For variant code 053 and 097 the dimension L1 and L2 is increased by 7.5 mm
D38 ISO k6 for the frame size 112 and 5.5 mm for the frame size 132.
DA ISO j6 5
) Two-speed motors, exkl. 132 S.
F, FA ISO h9 6
) Dimensions to UB1.
H +0 -0.5 7
) Dimensions to UB2 (VD1 = right side, VD2 = left side) as viewed from the D-end.
N ISO j6 8
) Not acc. to IEC.

ABB Motors 39
Wärtsilä id: VPENC000053 -
M2AA 112, 132
Basic design
Foot- and flange-mounted motor, IM 2001, IM 2002, IM B 35, large flange

Foot- and flange-mounted motor, IM 2101, IM 2102, IM B 34, small flange

IM 2001, IM 2002, IM B 35

Type
M2AA A1) AA AB AC AE B1) B' 1) BA BB BC C1) CA' 1) 4) CA1) 5) CB D1) DA1) DB DC E2) EA EG EH F1) FA1) G

112 M 190 41 222 221 160 140 - 31 168 31 70 111.5 138 14 28 19 M10 M8 60 40 22 19 8 6 24
132 S 216 47 262 261 160 140 1788) 40 212 76 89 158 191 18 38 24 M12 M8 80 50 28 19 10 8 33
132 M 216 47 262 261 160 1408) 178 40 212 76 89 120 153 18 38 24 M12 M8 80 50 28 19 10 8 33

Type
M2AA GA GB GC H1) HA HC HD HE K L14) L25) LC14) LC25) UB13) UB23) VA VB VC6) VD17) VD27)

112 M 31 15.5 21.5 112 12 226 258 92 12 361 388 421.5 448 Pr 22.5, Pg 16 Pr 28.3, Pg 21 60 160 80 120 40
132 S 41 20 27 132 14 263.5 295.5 109.5 12 447 447 517 517 Pr 22.5, Pg 16 Pr 28.3, Pg 21 71 160 80 120 40
132 M 41 20 27 132 14 263.5 295.5 109.5 12 447 481.5 517 550 Pr 22.5, Pg 16 Pr 28.3, Pg 21 71 160 80 120 40

IM 2001, IM B 35 IM 2101, IM B 34

Type Type
M2AA HB LA M N1) P S T M2AA HB LA M N1) P S T

112 146 11 215 180 250 14.5 4 112 146 20 130 110 160 M8 3.5
132 163.5 14 265 230 300 14.5 4 132 163.5 18 165 130 200 M10 3.5
2
1
) Tolerances ) Shoulder of shaft extension and contact surface of flange are in the same plan.
3
A, B ISO js14 ) Knockout openings.
4
C, CA +0 -2 ) Single-speed motors and two-speed motors 132 S.
D28 ISO j6 For variant code 053 and 097 the dimension L1 and L2 is increased by 7.5 mm
D38 ISO k6 for the frame size 112 and 5.5 mm for the frame size 132.
5
DA ISO j6 ) Two-speed motors, 132 S not included .
6
F, FA ISO h9 ) Dimension to UB1.
7
H +0 -0.5 ) Dimension to UB2 (VD1 = right side, VD2 = left side) as viewed from the D-end.
8
N ISO j6 ) Not acc. to IEC.

40 ABB Motors
Wärtsilä id: VPENC000053 -
M2AA 112, 132
High-output design
Foot-mounted motor IM 1001, IM 1002, IM B 3 Flange-mounted motor, large flange
IM 3001, IM 3002, IM B 5

Flange-mounted motor, small flange


IM 3601, IM 3602, IM B 14

IM 1001, IM 1002, IM B 3

Type
M2AA A1) AA AB AC AE B1) B' 1) BA BB BC C1) CA' 1)
CA1) CB D1) DA1) DB DC E2) EA EG EH F1) FA1) G GA

112 M 190 41 222 221 160 140 - 31 168 31 70 - 138 14 28 19 M10 M8 60 40 22 19 8 6 24 31


132 S 216 47 262 261 160 140 1786) 40 212 76 89 153 191 18 38 24 M12 M8 80 50 28 19 10 8 33 41
132 M 216 47 262 261 160 1406) 178 40 212 76 89 153 191 18 38 24 M12 M8 80 50 28 19 10 8 33 41

Type
M2AA GB GC H1) HA HC HD HE K L7) LC UB13) UB23) VA VB VC4) VD15) VD25)

112 M 15.5 21.5 112 12 226 258 92 12 388 448 Pr 22.5, Pg 16 Pr 28.3, Pg 21 60 160 80 120 40
132 S 20 27 132 14 263.5 295.5 109.5 12 481.5 550 Pr 22.5, Pg 16 Pr 28.3, Pg 21 71 160 80 120 40
132 M 20 27 132 14 263.5 295.5 109.5 12 481.5 550 Pr 22.5, Pg 16 Pr 28.3, Pg 21 71 160 80 120 40

IM 3001, IM B 5 IM 3601, IM B 14

Type Type
M2AA HB LA M N1) P S T M2AA HB LA M N1) P S T

112 146 11 215 180 250 14.5 4 112 146 20 130 110 160 M8 3.5
132 163.5 14 265 230 300 14.5 4 132 163.5 18 165 130 200 M10 3.5

2
1
) Tolerances ) Shoulder of shaft extension and contact surface of flange are in the same plane.
3
A, B ISO js14 ) Four knockout openings.
4
C, CA +0 -2 ) Dimension to UB1.
5
D28 ISO j6 ) Dimension to UB2 (VD1 = right side, VD2 = left side) as viewed from the D-end.
6
D38 ISO k6 ) Not acc. to IEC.
7)
DA ISO j6 For variant code 053 and 097 the dimension L is increased by 7.5 mm
F, FA ISO h9 for the frame size 112 and 5.5 mm for the frame size 132.
H +0 -0.5
N ISO j6

ABB Motors 41
Wärtsilä id: VPENC000053 -
M2AA 112, 132
High-output design

Foot-mounted and flange-mounted motor, IM 2001, IM 2002, IM B 35, large flange

Foot-mounted and flange-mounted motor, IM 2101, IM 2102, IM B 34, small flange

IM 2001, IM 2002, IM B 35

Type
M2AA A1) AA AB AC AE B1) B' 1) BA BB BC C1) 7) CA' 1) 7) CA1) CB D1) DA1) DB DC E2) EA EG EH F1) FA1) G

112 M 190 41 222 221 160 140 - 31 168 31 70 - 138 14 28 19 M10 M8 60 40 22 19 8 6 24


132 S 216 47 262 261 160 140 1786) 40 212 76 89 153 191 18 38 24 M12 M8 80 50 28 19 10 8 33
132 M 216 47 262 261 160 1406) 178 40 212 76 89 153 191 18 38 24 M12 M8 80 50 28 19 10 8 33

Type
M2AA GA GB GC H1) HA HC HD HE K L7) LC UB13) UB23) VA VB VC4) VD15) VD25)

112 M 31 15.5 21.5 112 12 226 258 92 12 388 448 Pr 22.5, Pg 16 Pr 28.3, Pg 21 60 160 80 120 40
132 S 41 20 27 132 14 263.5 295.5 109.5 12 481.5 550 Pr 22.5, Pg 16 Pr 28.3, Pg 21 71 160 80 120 40
132 M 41 20 27 132 14 263.5 295.5 109.5 12 481.5 550 Pr 22.5, Pg 16 Pr 28.3, Pg 21 71 160 80 120 40

IM 2001, IM B 35 IM 2101, IM B 34

Type Type
M2AA HB LA M N1) P S T M2AA HB LA M N1) P S T

112 146 11 215 180 250 14.5 4 112 146 20 130 110 160 M8 3.5
132 163.5 14 265 230 300 14.5 4 132 163.5 18 165 130 200 M10 3.5
2
1
) Tolerances ) Shoulder of shaft extension and contact surface of flange are in the same plan.
3
A, B ISO js14 ) Knockout openings.
4
C, CA +0 -2 ) Dimension to UB1.
5
D28 ISO j6 ) Dimension to UB2 (VD1 = right side, VD2 = left side) as viewed from the D-end.
6
D38 ISO k6 ) Not acc. to IEC.
7)
DA ISO j6 For variant code 053 and 097 the dimension L is increased by 7.5 mm
F, FA ISO h9 for the frame size 112 and 5.5 mm for the frame size 132.
H +0 -0.5
N ISO j6

42 ABB Motors
Wärtsilä id: VPENC000053 -
M2AA 160-180
Basic and high output design
Foot-mounted motor IM 1001, IM 1002, IM B 3

IM 1001, IM 1002, IM B 3

Type
M2AA A1) AA AB AC AE B1)7) B' 1)7) BA BB BC C1) CA1) CA' 1)
CB D1) DA1) DB DC E EA EG EH F1 )

160 3) 254 56 310 310 210 210 254 55 287.5 86 108 185.5 141.5 20 42 32 M16 M12 110 80 36 28 12
160 4) 254 56 310 310 210 210 254 55 287.5 86 108 226.5 182.5 20 42 32 M16 M12 110 80 36 28 12
180 5) 279 65.5 340 360 210 241 279 58 316 88 121 218 180 25 48 32 M16 M12 110 80 36 28 14
180 6) 279 65.5 340 360 210 241 279 58 316 88 121 238 200 25 48 32 M16 M12 110 80 36 28 14

Type
M2AA FA1) G GA GB GC H1) HA HC HD HE K L LC UB2) UB22) VA VB VC VD VE

160 3) 10 37 45 27 35 160 20 325 370 130 15 602.5 693.5 Pr 37, Pg 29 Pr 15.4, Pg 9 89 210 84.5 134.5 167.5
160 4) 10 37 45 27 35 160 20 325 370 130 15 643.5 734.5 Pr 37, Pg 29 Pr 15.4, Pg 9 89 210 84.5 134.5 167.5
180 5) 10 42.5 51.5 27 35 180 20 360 405 145 15 680 770 Pr 37, Pg 29 Pr 15.4, Pg 9 77.5 210 84.5 134.5 167.5
180 6) 10 42.5 51.5 27 35 180 20 360 405 145 15 700.5 790 Pr 37, Pg 29 Pr 15.4, Pg 9 77.5 210 84.5 134.5 167.5
2
1
) Tolerances ) Knockout openings.
3
A, B ISO js14 ) M-2, MA-2, M-4, M-6, M-8, MA-8, L-2, L-4, L-6,
C, CA +0 -2 MA-2/4, M-2/4, L-2/4, M-4/6, M-4/8, LB-2 and LB-4
4
D, DA ISO k6 ) L-8, L-4/6, L-4/8, LB-6 and LB-8
5
F, FA ISO h9 ) M-2, M-4, L-4, L-6, L-8, M-2/4, M-4/6, M-4/8 and LB-2
6
H +0 -0.5 ) L-2/4, L-4/6, L-4/8, LB-4, LB-6 and LB-8
7
) 160 M: B' not acc. to IEC
160 L: B not acc. to IEC
180 M: B' not acc. to IEC
180 L: B not acc. to IEC

ABB Motors 43
Wärtsilä id: VPENC000053 -
M2AA 160-180
Basic and high output design
Flange-mounted motor IM 3001, IM 3002, IM B 5

IM 3001, IM 3002, IM B 5

Type
M2AA AC AE D1) DA1) DB DC E7) EA EG EH F1) FA1) G GA GB GC HB HE
3
160 ) 310 210 42 32 M16 M12 110 80 36 28 12 10 37 45 27 35 210 130
160 4) 310 210 42 32 M16 M12 110 80 36 28 12 10 37 45 27 35 210 130
180 5) 360 210 48 32 M16 M12 110 80 36 28 14 10 42.5 51.5 27 35 225 145
180 6) 360 210 48 32 M16 M12 110 80 36 28 14 10 42.5 51.5 27 35 225 145

Type
M2AA L LA LB LC M N1) P S T UB12) UB22) VA VB VC VD VE

160 3) 602.5 16 492.5 693.5 300 250 350 19 5 Pr 37, Pg 29 Pr 15.4, Pg 9 89 210 84.5 134.5 167.5
160 4) 643.5 16 533.5 734.5 300 250 350 19 5 Pr 37, Pg 29 Pr 15.4, Pg 9 89 210 84.5 134.5 167.5
180 5) 680 21 570 770 300 250 350 19 5 Pr 37, Pg 29 Pr 15.4, Pg 9 77.5 210 84.5 134.5 167.5
180 6) 700.5 21 590.5 790 300 250 350 19 5 Pr 37, Pg 29 Pr 15.4, Pg 9 77.5 210 84.5 134.5 167.5
1
) Tolerances 3
) M-2, MA-2, M-4, M-6, M-8, MA-8, L-2, L-4, L-6,
D, DA ISO k6 MA-2/4, M-2/4, L-2/4, M-4/6, M-4/8, LB-2 and LB-4
F, FA ISO h9 4
) L-8, L-4/6, L-4/8, LB-6 and LB-8
N ISO j6 5
) M-2, M-4, L-4, L-6, L-8, M-2/4, M-4/6, M-4/8 and LB-2
2
) Knockout openings. 6
) L-2/4, L-4/6, L-4/8, LB-4, LB-6 and LB-8
7
) Shoulder of shaft extension and contact surface of flange are in the same plane.

44 ABB Motors
Wärtsilä id: VPENC000053 -
M2AA 160-180
Basic design and high-output design
Foot- and flange-mounted motor IM 2001, IM 2002, IM B 35

IM 2001, IM 2002, IM B 35

Type
M2AA A1) AA AB AC AE B1)8) B' 1)8)
BA BB BC C1) CA1) CA' 1)
CB D1) DA1) DB DC E7) EA EG EH F1)

160 3) 254 56 310 310 210 210 254 55 287.5 86 108 185.5 141.5 20 42 32 M16 M12 110 80 36 28 12
160 4) 254 56 310 310 210 210 254 55 287.5 86 108 226.5 182.5 20 42 32 M16 M12 110 80 36 28 12
180 5) 279 65.5 340 360 210 241 279 58 316 88 121 218 180 25 48 32 M16 M12 110 80 36 28 14
180 6) 279 65.5 340 360 210 241 279 58 316 88 121 238 200 25 48 32 M16 M12 110 80 36 28 14

Type
M2AA FA1) G GA GB GC H1) HA HB HC HD HE K L LA LB LC M N1) P S
3)
160 10 37 45 27 35 160 20 210 325 370 130 15 602.5 16 492.5 693.5 300 250 350 19
160 4) 10 37 45 27 35 160 20 210 325 370 130 15 643.5 16 533.5 734.5 300 250 350 19
180 5) 10 42.5 51.5 27 35 180 20 225 360 405 145 15 680 21 570 770 300 250 350 19
180 6) 10 42.5 51.5 27 35 180 20 225 360 405 145 15 700.5 21 590.5 790 300 250 350 19

Type
M2AA T UB2) UB22) VA VB VC VD VE

160 3) 5 Pr 37, Pg 29 Pr 15.4, Pg 9 89 210 84.5 134.5 167.5


160 4) 5 Pr 37, Pg 29 Pr 15.4, Pg 9 89 210 84.5 134.5 167.5
180 5) 5 Pr 37, Pg 29 Pr 15.4, Pg 9 77.5 210 84.5 134.5 167.5
180 6) 5 Pr 37, Pg 29 Pr 15.4, Pg 9 77.5 210 84.5 134.5 167.5
2
1
) Tolerances ) Knockout openings.
3
A, B ISO js14 ) M-2, MA-2, M-4, M-6, M-8, MA-8, L-2, L-4, L-6,
C, CA +0 -2 MA-2/4, M-2/4, L-2/4, M-4/6, M-4/8, LB-2 and LB-4
4
D, DA ISO k6 ) L-8, L-4/6, L-4/8, LB-6 and LB-8
5
F, FA ISO h9 ) M-2, M-4, L-4, L-6, L-8, M-2/4, M-4/6, M-4/8 and LB-2
6
H +0 -0.5 ) L-2/4, L-4/6, L-4/8, LB-4, LB-6 and LB-8
7
N ISO j6 ) Shoulder of shaft extension and contact surface of
flange are in the same plan.
8
) 160 M: B' not acc. to IEC
160 L: B not acc. to IEC
180 M: B' not acc. to IEC
180 L: B not acc. to IEC

ABB Motors 45
Wärtsilä id: VPENC000053 -
M2AA 200-250
Basic design

Foot-mounted motor IM 1001, IM 1002, IM B 3

Dimension AD and HD refer to side


mounted terminal box, see page 52.

IM 1001, IM 1002, IM B 3

Type IEC- No. of


M2AA size poles A1) AA AB AC AE B1) B'1) BA BB C1) CA1) CA' 1)
CB D1) DA1) DB DC E EA EG EH
5)
200 ML. 200 M 2-8 318 64 380 386 243 267 305 98 365 133 273 235 30 55 45 M20 M16 110 110 42 36
200 ML. 200 L 2-8 318 64 380 386 243 2675) 305 98 365 133 273 235 30 55 45 M20 M16 110 110 42 36
225 SM. 225 S 4, 8 356 69 418 425 243 286 3115) 84 360 149 300 275 24.5 60 55 M20 M20 140 110 42 42
225 SM. 225 M 2, 2/4 356 69 418 425 243 2865) 311 84 360 149 300 275 24.5 55 55 M20 M20 110 110 42 42
225 SM. 225 M 4-8 356 69 418 425 243 2865) 311 84 360 149 300 275 24.5 60 55 M20 M20 140 110 42 42
250 SM. 250 S 2 406 78 474 471 243 311 3495) 94.5 409 168 263 225 40 60 55 M20 M20 140 110 42 42
250 SM. 250 S 4-8 406 78 474 471 243 311 3495) 94.5 409 168 263 225 30 65 55 M20 M20 140 110 42 42
250 SM. 250 M 2, 2/4 406 78 474 471 243 3115) 349 94.5 409 168 263 225 40 60 55 M20 M20 140 110 42 42
250 SM. 250 M 4-8 406 78 474 471 243 3115) 349 94.5 409 168 263 225 30 65 55 M20 M20 140 110 42 42

Type IEC- No. of


M2AA size poles F1) FA1) G GA GB GC H1) HA HD HE K L LC UB2) VA VB VC3) VC4) VD3) VD4)

200 ML. 200 M 2-8 16 16 49 59 39 49 200 25 500.5 224 18 774 893 2 x FL 13 75.5 243 118 89.5 168 163.5
200 ML. 200 L 2-8 16 16 49 59 39 49 200 25 500.5 224 18 774 893 2 x FL 13 75.5 243 118 89.5 168 163.5
225 SM. 225 S 4, 8 18 16 53 64 49 59 225 25 546 244.5 18 866 985 2 x FL 13 93.5 243 118 89.5 168 163.5
225 SM. 225 M 2, 2/4 16 16 49 59 49 59 225 25 546 244.5 18 836 955 2 x FL 13 93.5 243 118 89.5 168 163.5
225 SM. 225 M 4-8 18 16 53 64 49 59 225 25 546 244.5 18 866 985 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 S 2 18 16 53 64 49 59 250 40 594 267.5 22 875 992 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 S 4-8 18 16 58 69 49 59 250 30 594 267.5 22 875 992 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 2 18 16 53 64 49 59 250 40 594 267.5 22 875 992 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 2/4 18 16 53 64 49 59 250 30 594 267.5 22 875 992 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 4-8 18 16 58 69 49 59 250 30 594 267.5 22 875 992 2 x FL 13 93.5 243 118 89.5 168 163.5
1
) Tolerances
A, B ISO js14
C, CA +0 -2
DA 45-55 ISO k6
D 55-65 ISO m6
F, FA ISO h9
H +0 -0.5
2
) Flange opening is provided with pipe flange FL 13, with tapped
lead-in holes plugged with sealing plugs.
Single- and two-speed motors: 2 x Pr 37, 2 x Pg 29
Motors for 230 V 50 Hz have pipe flange FL 21 and 2 x Pr 54, 2 x Pg 42.
3
) For flange opening FL 13: 2 x Pr 37, 2 x Pg 29
4
) For extra large terminal box with flange opening FL 21: 2 x Pr 54, 2 x Pg 42.
5
) Not acc. to IEC.

46 ABB Motors
Wärtsilä id: VPENC000053 -
M2AA 200-250
Basic design

Flange-mounted motor IM 3001, IM 3002, IM B 5

M2AA 200

M2AA 225-250
IM 3001, IM 3002, IM B 5

Type IEC- No. of


M2AA size poles AC AE D1) DA1) DB DC E2) EA EG EH F1) FA G GA GB GC HB HE

200 ML. 200 M 2-8 386 243 55 45 M20 M16 110 110 42 36 16 16 49 59 39 49 300.5 224
200 ML. 200 L 2-8 386 243 55 45 M20 M16 110 110 42 36 16 16 49 59 39 49 300.5 224
225 SM. 225 S 4, 8 427 243 60 55 M20 M20 140 110 42 42 18 16 53 64 49 59 321 244.5
225 SM. 225 M 2, 2/4 427 243 55 55 M20 M20 110 110 42 42 16 16 49 59 49 59 321 244.5
225 SM 225 M 4-8 427 243 60 55 M20 M20 140 110 42 42 18 16 53 64 49 59 321 244.5
250 SM. 250 S 2 471 243 60 55 M20 M20 140 110 42 42 18 16 53 64 49 59 344 267.5
250 SM. 250 S 4-8 471 243 65 55 M20 M20 140 110 42 42 18 16 58 69 49 59 344 267.5
250 SM. 250 M 2, 2/4 471 243 60 55 M20 M20 140 110 42 42 18 16 53 64 49 59 344 267.5
250 SM. 250 M 4-8 471 243 65 55 M20 M20 140 110 42 42 18 16 58 69 49 59 344 267.5

Type IEC- No. of


M2AA size poles L LA LB LC M N1) P S T UB3) VA VB VC4) VC5) VD4) VD5)

200 ML. 200 M 2-8 774 20 664 893 350 300 400 19 5 2 x FL 13 75.5 243 118 89.5 168 163.5
200 ML. 200 L 2-8 774 20 664 893 350 300 400 19 5 2 x FL 13 75.5 243 118 89.5 168 163.5
225 SM. 225 S 4, 8 866 22 726 985 400 350 450 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
225 SM. 225 M 2, 2/4 836 22 726 955 400 350 450 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
225 SM. 225 M 4-8 866 22 726 985 400 350 450 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 S 2 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 S 4-8 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 2, 2/4 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 4-8 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
2
1
) Tolerances ) Shoulder of shaft extension and contact surface of flange are in the same plane.
3
DA 45-55 ISO k6 ) Flange opening is provided with pipe flange FL 13, with tapped
D 55-65 ISO m6 lead-in holes plugged with sealing plugs.
F, FA ISO h9 Single- and two-speed motors: 2 x Pr 37, 2 x Pg 29
N ISO js6 Motors for 230 V 50 Hz have pipe flange FL 21 and 2 x Pr 54, 2 x Pg 42.
4
) For flange opening FL 13: 2 x Pr 37, 2 x Pg 29
5
) For extra large terminal box with flange opening FL 21: 2 x Pr 54, 2 x Pg 42.

ABB Motors 47
Wärtsilä id: VPENC000053 -
M2AA 200-250
Basic design

Foot- and flange-mounted motor IM 2001, IM 2002, IM B 35

M2AA 200

M2AA 225-250
IM 2001, IM 2002, IM B 35

Type IEC- No. of


M2AA size poles A1) AA AB AC AE B1) B'1) BA BB C1) CA1) CA' 1)
CB D1) DA1) DB DC E5) EA EG EH F1) FA1) G GA
6)
200 ML. 200 M 2-8 318 64 380 386 243 267 305 98 365 133 273 235 30 55 45 M20 M16 110 110 42 36 16 16 49 59
200 ML. 200 L 2-8 318 64 380 386 243 2676) 305 98 365 133 273 235 30 55 45 M20 M16 110 110 42 36 16 16 49 59
225 SM. 225 S 4, 8 356 69 418 425 243 286 3116) 84 360 149 300 275 24.5 60 55 M20 M20 140 110 42 42 18 16 53 64
225 SM. 225 M 2, 2/4 356 69 418 425 243 2866) 311 84 360 149 300 275 24.5 55 55 M20 M20 110 110 42 42 16 16 49 59
225 SM. 225 M 4-8 356 69 418 425 243 2866) 311 84 360 149 300 275 24.5 60 55 M20 M20 140 110 42 42 18 16 53 64
250 SM. 250 S 2 406 78 474 471 243 311 3496) 94.5 409 168 263 225 40 60 55 M20 M20 140 110 42 42 18 16 53 64
250 SM. 250 S 4-8 406 78 474 471 243 311 3496) 94.5 409 168 263 225 30 65 55 M20 M20 140 110 42 42 18 16 58 69
250 SM. 250 M 2, 2/4 406 78 474 471 243 3116) 349 94.5 409 168 263 225 40 60 55 M20 M20 140 110 42 42 18 16 53 64
250 SM. 250 M 4-8 406 78 474 471 243 3116) 349 94.5 409 168 263 225 30 65 55 M20 M20 140 110 42 42 18 16 58 69

Type IEC- No. of


M2AA size poles GB GC H1) HA HD HE K L LA LB LC M N1) P S T UB2) VA VB VC3) VC4) VD3) VD4)

200 ML. 200 M 2-8 39 49 200 25 500.5 224 18 774 20 664 893 350 300 400 19 5 2 x FL 13 75.5 243 118 89.5 168 163.5
200 ML. 200 L 2-8 39 49 200 25 500.5 224 18 774 20 664 893 350 300 400 19 5 2 x FL 13 75.5 243 118 89.5 168 163.5
225 SM. 225 S 4, 8 49 59 225 25 546 244.5 18 866 22 726 985 400 350 450 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
225 SM. 225 M 2, 2/4 49 59 225 25 546 244.5 18 836 22 726 955 400 350 450 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
225 SM. 225 M 4-8 49 59 225 25 546 244.5 18 866 22 726 985 400 350 450 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 S 2 49 59 250 40 594 267.5 22 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 S 4-8 49 59 250 30 594 267.5 22 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 2 49 59 250 40 594 267.5 22 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 2/4 49 59 250 30 594 267.5 22 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 4-8 49 59 250 30 594 267.5 22 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
1 2
) Tolerances ) Flange opening is provided with pipe flange FL 13, with tapped
A, B ISO js14 lead-in holes plugged with sealing plugs.
C, CA +0 -2 Single- and two-speed motors: 2 x Pr 37, 2 x Pg 29
D 55-65 ISO m6 Motors for 230 V 50 Hz have pipe flange FL 21 and 2 x Pr 54, 2 x Pg 42.
3
DA 45-55 ISO k6 ) For flange opening FL 13: 2 x Pr 37, 2 x Pg 29
4
F, FA ISO h9 ) For extra large terminal box with flange opening FL 21: 2 x Pr 54, 2 x Pg 42.
5
H +0 -0.5 ) Shoulder of shaft extension and contact surface of flange are in the same plane.
6
N ISO js6 ) Not acc. to IEC.

48 ABB Motors
Wärtsilä id: VPENC000053 -
M2AA 200-250
High-output design

Foot-mounted motor IM 1001, IM 1002, IM B 3

Dimension AD and HD refer to side


mounted terminal box, see page 52.

IM 1001, IM 1002, IM B 3

Type IEC- No.of


M2AA size poles A1) AA AB AC AE B'1) BA BB C1) CA1) CA' 1)
CB D1) DA1) DB DC E EA EG EH

200 ML. 200 L 2-8 318 64 380 386 243 305 98 365 133 273 235 30 55 45 M20 M16 110 110 42 36
225 SM. 225 M 2 356 69 418 425 243 311 84 360 149 300 275 24.5 55 55 M20 M20 110 110 42 42
225 SM. 225 M 4-8 356 69 418 425 243 311 84 360 149 300 275 24.5 60 55 M20 M20 140 110 42 42
250 SM. 250 M 2 406 78 474 471 243 349 94.5 409 168 263 225 30 60 55 M20 M20 140 110 42 42
250 SM. 250 M 4-8 406 78 474 471 243 349 94.5 409 168 263 225 30 65 55 M20 M20 140 110 42 42

Type IEC- No. of


M2AA size poles F1) FA1) G GA GB GC H1) HA HD HE K L LC UB2) VA VB VC3) VC4) VD3) VD4)

200 ML. 200 L 2-8 16 16 49 59 39 49 200 25 500.5 224 18 774 893 2 x FL 13 75.5 243 118 89.5 168 163.5
225 SM. 225 M 2 16 16 49 59 49 59 225 25 546 244.5 18 836 955 2 x FL 13 93.5 243 118 89.5 168 163.5
225 SM. 225 M 4-8 18 16 53 64 49 59 225 25 546 244.5 18 866 985 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 2 18 16 53 64 49 59 250 40 594 267.5 22 875 992 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 4-8 18 16 58 69 49 59 250 30 594 267.5 22 875 992 2 x FL 13 93.5 243 118 89.5 168 163.5
1
) Tolerances
A, B ISO js14
C, CA +0 -2
DA 42 ISO k6
D, DA 55-60 ISO m6
F, FA ISO h9
H +0 -0.5
2
) Flange opening is provided with pipe flange FL 13, with tapped
lead-in holes plugged with sealing plugs, 2 x Pr 37, 2 x Pg 29.
3
) For flange opening FL 13: 2 x Pr 37, 2 x Pg 29.
4
) For extra large terminal box with flange opening FL 21: 2 x Pr 54, 2 x Pg 42.

ABB Motors 49
Wärtsilä id: VPENC000053 -
M2AA 200-250
High-output design

Flange-mounted motor IM 3001, IM 3002, IM B 5

M2AA 200

M2AA 225-250
IM 3001, IM 3002, IM B 5

Type IEC- No. of


M2AA size poles AC AE D1) DA1) DB DC E2) EA EG EH F1) FA G GA GB GC HB HE

200 ML. 200 L 2-8 386 243 55 45 M20 M16 110 110 42 36 16 16 49 59 39 49 300.5 224
225 SM. 225 M 2 427 243 55 55 M20 M20 110 110 42 42 16 16 49 59 49 59 321 244.5
225 SM. 225 M 4-8 427 243 60 55 M20 M20 140 110 42 42 18 16 53 64 49 59 321 244.5
250 SM. 250 M 2 471 243 60 55 M20 M20 140 110 42 42 18 16 53 64 49 59 344 267.5
250 SM. 250 M 4-8 471 243 65 55 M20 M20 140 110 42 42 18 16 58 69 49 59 344 267.5

Type IEC- No. of


M2AA size poles L LA LB LC M N P S T UB3) VA VB VC4) VC5) VD4) VD5)

200 ML. 200 L 2-8 774 20 664 893 350 300 400 19 5 2 x FL 13 75.5 243 118 89.5 168 163.5
225 SM. 225 M 2 836 22 726 955 400 350 450 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
225 SM. 225 M 4-8 866 22 726 985 400 350 450 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 2 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 4-8 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
1
) Tolerances
DA 42 ISO k6
D, DA 55-60 ISO m6
F, FA ISO h9
N ISO js6
2
) Shoulder of shaft extension and contact surface of
flange are in the same plane.
3
) Flange opening is provided with pipe flange FL 13, with tapped lead-in holes
plugged with sealing plugs.
Single- and two-speed motors: 2 x Pr 37, 2 x Pg 29
Motors for 230 V 50 Hz have pipe flange FL 21 and 2 x Pr 54, 2 x Pg 42.
4
) For flange opening FL 13: 2 x Pr 37, 2 x Pg 29.
5
) For extra large terminal box with flange opening FL 21: 2 x Pr 54, 2 x Pg 42

50 ABB Motors
Wärtsilä id: VPENC000053 -
M2AA 200-250
High-output design

Foot- and flange-mounted motor IM 2001, IM 2002, IM B 35

M2AA 200

M2AA 225-250

IM 2001, IM 2002, IM B 35

Type IEC- No.of


M2AA size poles A1) AA AB AC AE B1) B'1) BA BB C1) CA1) CA' 1)
CB D1) DA1) DB DC E5) EA EG EH F1) FA1) G GA

200 ML. 200 L 2-8 318 64 380 386 243 267 305 98 365 133 273 235 30 55 45 M20 M16 110 110 42 36 16 16 49 59
225 SM. 225 M 2 356 69 418 425 243 286 311 84 360 149 300 275 24.5 55 55 M20 M20 110 110 42 42 16 16 49 59
225 SM. 225 M 4-8 356 69 418 425 243 286 311 84 360 149 300 275 24.5 60 55 M20 M20 140 110 42 42 18 16 53 64
250 SM. 250 M 2 406 78 474 471 243 311 349 94.5 409 168 263 225 40 60 55 M20 M20 140 110 42 42 18 16 53 64
250 SM. 250 M 4-8 406 78 474 471 243 311 349 94.5 409 168 263 225 30 65 55 M20 M20 140 110 42 42 18 16 58 69

Type IEC- No. of


M2AA size poles GB GC H1) HA HD HE K L LA LB LC M N1) P S T UB2) VA VB VC3) VC4) VD3) VD4)

200 ML. 200 L 2-8 39 49 200 25 500.5 224 18 774 20 664 893 350 300 400 19 5 2 x FL 13 75.5 243 118 89.5 168 163.5
225 SM. 225 M 2 49 59 225 25 546 244.5 18 836 22 726 955 400 350 450 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
225 SM. 225 M 4-8 49 59 225 25 546 244.5 18 866 22 726 985 400 350 450 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 2 49 59 250 40 594 267.5 22 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
250 SM. 250 M 4-8 49 59 250 30 594 267.5 22 875 22 735 992 500 450 550 19 5 2 x FL 13 93.5 243 118 89.5 168 163.5
1
) Tolerances
A, B ISO js14
C, CA +0 -2
D 55-65 ISO m6
DA 45-55 ISO k6
F, FA ISO h9
H +0 -0.5
N ISO j6
2
) Flange opening is provided with pipe flange FL 13, with tapped
lead-in holes plugged with sealing plugs, 2 x Pr 37, 2 x Pg 29.
3
) For flange opening FL 13: 2 x Pr 37, 2 x Pg 29.
4
) For extra large terminal box with flange opening FL 21: 2 x Pr 54, 2 x Pg 42.
5
) Shoulder of shaft extension and contact surface of flange are in the same plane.

ABB Motors 51
Wärtsilä id: VPENC000053 -
Dimensions for alternative designs

Protective roof Terminal box


Code 005 Vertically mounted motors with shaft Code 019 Larger than standard terminal box
extension downwards Type Dimensions
M2AA AD HB HD HE
Type No. of Dimension
M2AA IEC-size poles L 200 ML. 332.5 332.5 532.5 240
63 223 225 SM. 353 353 578 260.5
71 250 250 SM. 376 376 626 283.5
80 282 Code 021 Terminal box on left-hand side, seen from D end
90 S 305 Code 180 Terminal box on right-hand side, seen from D end
90 L 330
100 L 368 Type Dimensions
M2AA AD HD
112 M Single-speed motors 400
132 S 484 200 ML. 300.5 412.5
132 M 484 225 SM. 321 452
250 SM. 344 494
112 M Two-speed motors and 428
132 S high-output design 522 Kod 467 Lower than standard terminal box without screw
132 M 522 terminals and extended rubber connection cable,
1
160 ) 730 3 m.
2
160 ) 771 M2AA 112-180 has standard terminal box with
3
180 ) 813.5 low, flat cover.
4
180 ) 834
Type Dimensions
200 ML. 200 M 2-8 823 M2AA AD HB HD
225 SM. 225 M 2, 2/4 885
225 SM. 225 M 4-8 915 112 M 123.5 235.5
250 SM. 250 S 2-8 922 132 S 141 273
250 SM. 250 M 2-8 922 132 M 141 273
160 211.5 371.5
1
) M-2, MA-2, M-4, M-6, M-8, MA-8, L-2, L-4, L-6. MA-2/4, M-2/4, L-2/4, M-4/6, 180 226.5 406.5
M-4/8, LB-2 and LB-4.
2
) L-8, L-4/6, L-4/8, LB-6 and LB-8. 200 ML. 248 248 448
3
) M-2, M-4, L-4, L-6, L-8, M-2/4, M-4/6, M-4/8 and LB-2. 225 SM. 269 269 494
4
) L-2/4, L-4/6, L-4/8, LB-4, LB-6 and LB-8. 250 SM. 292 292 542

52 ABB Motors
Wärtsilä id: VPENC000053 -

Accessories
Slide rails
The slide rails are manufactured from steel. Each order
number includes two complete slide rails, including
fixing screws, for the motor. Fixing screws for the slide
rails are not included. Slide rails are supplied with
rough lower surfaces and, prior to tightening down,
should be supported in a suitable manner.

MSP-0, -1, -2 and -3 MSP-4 and -5

Dimensions
KA KB Motor Weight/pair
Type for screw for screw X XB XE Y YA YB Z ZA bolt kg

MSP-0 M10 - 330 305 12.5 30 - - 35 6 M6 1.5


MSP-1 M10 - 330 305 12.5 30 - - 35 6 M8 1.5
MSP-2 M12 - 495 465 15 40 - - 37 6 M10 2.5
MSP-3 M16 - 595 550 22.5 50 . . 40 10 M12 3.5
MSP-4 M20 - 720 680 20 - - 80 45 20 M16 9.5
MSP-5 M24 M16 900 850 25 200 150 100 50 25 M20 14.5

Ordering table
Motor Catalogue
Type size XA min. XA max. XC XF No.

MSP-0 63 105 210 45 0 MK 911 011-1


71 111 201 40 0
MSP-1 80 118 188 40 0 MK 911 011-2
90 125 180 40 0
MSP-2 100 145 275 45 70 MK 911 011-3
112 151 314 40 25
132 171 294 40 0
MSP-3 160 207 342 50 0 MK 911 011-4
180 210 340 40 0
MSP-4 200 280 400 90 45 MK 911 011-5
225 274 406 65 35
MSP-5 250 337 513 100 0 MK 911 011-6

ABB Motors 53
Wärtsilä id: VPENC000053 -
Foundation studs
Foundation studs are intended for use instead of base
plates. Each set of foundation studs includes four
studs. Fixing screws for mounting the motor and two
conical pins for locking the motor in position on the
foundation studs are supplied.

Ordering table
Motor Weight/kit Catalogue
size B1 B2 D d g H h S p kg No.

112, 132 60 90 25 M10 25 125 8 30 200 3 MK 911 974-AA


160,180 70 110 25 M12 35 150 10 35 200 4 MK 911 975-AA
200, 225 80 140 28 M16 35 180 10 40 250 7 MK 911 976-AA
250 100 150 35 M20 40 200 10 50 270 10 MK 911 977-AA

Touch-up paint
Touch-up paint in spray cans, gross content 400 ml. The paint is of alkyd
base type.

Order no. Language on label


3GZ V 515 001-34 Swedish, Finnish, Norwegian and Danish
3GZ V 515 001-35 English, German, French and Spanish

54 ABB Motors
ABB Motors Wärtsilä id: VPENC000053 -

Aluminium motors in brief. Basic design.


Size 63 71 80 90 100

Stator and feet Material Diecast aluminium alloy. Feet integrated with stator.
Surface treatment One-component modified polyester paint. Munsell blue 8B 4.5/3.25 / NCS 4822 BO5G. •30 µm.
Bearing end shields Material Diecast aluminium alloy.
Surface treatment One-component modified polyester paint. Munsell blue 8B 4.5/3.25 / NCS 4822 BO5G. •30 µm.
Bearings D-end 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6305-2Z/C3 6306-2Z/C3
Single-speed motors N-end 6202-2Z/C3 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3
Bearings D-end 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6305-2Z/C3 6306-2Z/C3
Two-speed motors N-end 6202-2Z/C3 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3
1) 1) 1)
Axially-locked Inner bearing cover D-end D-end
1
bearings ) Foot motor. A spring-washer at the N-end presses the rotor towards the D-end.
Bearing seals D-end V ring.
N-end Labyrinth seal.
Lubrication Permanently lubricated bearings. Grease for bearing temperatures -25 to +150 °C.
Terminal box Material Diecast aluminium alloy.
Surface treatment Similar to stator.
Screws Steel 5 G. Galvanised and yellow chromated.
Connections Knockout openings 4 x Pr 18.6 4 x Pr 22.5
4 x Pg 11 4 x Pg 16
Terminal box Screw terminal. 6 terminals.
Max Cu-area, mm2 2.5
Fan Material Polypropylene. Reinforced with 20% glass fibre.
Fan hood Material Polypropylene.
Stator winding Material Copper.
Impregnation Polyester varnish. Tropicalised.
Insulation class Insulation class F. Temperature rise class B, unless otherwise stated.
Stator winding See "Stator winding temperature sensors " in the catalogue on p. 10, 33 and 34.
temperature sensors
Rotor winding Material Diecast aluminium.
Enclosure IP 55.
Cooling method IC 411.
Drain holes Variant code 066 or 076.
55
Wärtsilä id: VPENC000053 -
Aluminium motors in brief. Basic design (cont)
56

Size 112 132 S 132 M 160 180 200 225 250

Stator Material Diecast aluminium alloy. Extruded aluminium alloy.


Surface treatment Polyester powder paint. Munsell blue 8B 4.5/3.25 / NCS 4822 BO5G. •50 µm.
Feet Material Aluminium alloy. Integrated with the stator. Aluminium alloy, bolted to the stator. 250-2, cast iron
Bearing end shields Material Diecast aluminium alloy. Flanged bearing end shields of cast iron. Other diecast aluminium alloy
Surface treatment Polyester powder paint. Munsell blue 8B 4.5/3.25 / NCS 4822 BO5G. •50 µm.
Bearings D-end 6206-2Z/C3 6208-2Z/C3 6208-2Z/C3 6309-2Z/C3 6310-2Z/C3 6312/C3 6313/C3 6315/C3
Single-speed motors N-end 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 6209-2Z/C3 6209-2Z/C3 6210/C3 6212/C3 6213/C3
Bearings D-end 6206-2Z/C3 6208-2Z/C3 6208-2Z/C3 6309-2Z/C3 6310-2Z/C3 6312/C3 6313/C3 6315/C3
Two-speed motors N-end 6206-2Z/C3 6206-2Z/C3 6208-2Z/C3 6209-2Z/C3 6209-2Z/C3 6210/C3 6212/C3 6213/C3
1)
Axially-locked Inner bearing cover D-end1) D-end1) D-end D-end N-end N-end N-end
1
bearings ) Foot motors. A spring-washer at the N-end presses the rotor towards the D-end.
Flange-mounted motors: Inner bearing cover and spring-washer at the N-end.
Bearing seals D-end V ring. Outer and inner V rings.
N-end Two-speed motors sizes 112 and 132 M, V ring. Other labyrinth seal. Outer and inner V rings.
Lubrication Permanently lubricated bearings. Valve lubrication.
Grease for bearing temperatures -30 to +110 °C. Grease for bearing temperatures -30 to +110 °C.
Terminal box Material Diecast aluminium alloy. Base integrated with stator. Deep-drawn steel sheet, bolted to stator.
Surface treatment Similar to stator. Phosphated. Polyester paint.
Screws Steel. Galvanised and chromated.
Connections Knockout openings 2 x (Pr 28.3 + Pr 22.5) 4 x Pr 37 + 2 x Pr 15.4
2 x (Pg 21 + Pg 16) 4 x Pg 29 + 2 x Pg 9
Flange openings 2 x FL 13, 2 x Pr 37
2 x Pg 29
Flange openings for 2 x FL 21, 2 x Pr 54
voltage code S 2 x Pg 42
Terminal box Cable lugs. 6 terminals.
Screws M5 M5 M5 M6 M6 M10 M10 M10
Max Cu-area, mm2 10 10 10 35 35 70 70 70
Fan Material Polypropylene. Reinforced with 20% glass fibre.
Fan hood Material Polypropylene. See also note 1). Steel sheet. 1) 1
) Also two-speed motors
Surface treatment Phosphated. Polyester paint.1) sizes 112 and 132 M.
Stator winding Material Copper.
Impregnation Polyester varnisch. Tropicalised.
Insulation class Insulation class F. Temperature rise class B, unless otherwise stated.
Stator winding See "Stator winding temperature sensors " in the catalogue on p. 10, 33. PTC thermistors. 150 °C. 3 in series.
temperatur sensors
ABB Motors

Rotor winding Material Diecast aluminium.


Enclosure IP 55.
Cooling method IC 411.
Drain holes Drain holes with closable plastic plugs. Open on delivery.
Wärtsilä id: VPENC000053 -

ABB Motors product range


Motor type/application IEC frame sizes Output kW
Three-phase motors, IP 55 63 - 400 0.18 - 710
Ex nA motors 63 - 400 0.18 - 630
EEx e motors 63 - 400 0.18 - 390
EEx d/EEx de motors 80 - 400 0.55 - 630
Marine motors 63 - 400 0.18 - 630
IP 23 S open drip proof motors 250 - 400 75 - 800
Single-phase motors 63 - 100 0.15 - 2.2
Brake motors 71 - 400 0.25 - 710
Integral motors 80 - 132 0.75 - 7.5

Basic alternatives Special types/alternatives


– aluminium, steel and cast iron frames available – special variable speed AC drives
– LV motors up to 1000 V – high speed motors, over 3000 r/min
– standard versions of all types kept in stock – traction motors
– larger LV and HV motors can also be supplied – generators for wind mills
– motors according to NEMA-standard – roller tables and mines
– water cooled motors
– slip-ring motors
– motors with vertical hollow shaft
– smoke venting design
– stator/rotor units

ABB Motors' new range of aluminium motors meet the highest efficiency and operational
reliability levels demanded by many of today's industrial processes.

Catalogues and brochures


for these motors are available from:

ABB Motors
Marketing Communications
P.O. Box 633
FIN-65101 Vaasa
Tel. +358 10 22 4000
Fax +358 10 22 43575
www.abb.com/motors

ABB Motors 57
Wärtsilä id: VPENC000053 -

ABB Motors' new aluminium series covers a vast application


range. Shown here is the 45 kW type M2AA 225 SMB, 5.5 kW
type M2AA 132 SA and 1.5 kW type M2AA 90 L.

58 ABB Motors
Wärtsilä id: VPENC000053 -

Typical modern totally-enclosed squirrel-cage three-phase motor


Type M2AA 132 M, 7.5 kW IP 55 IC 411 1450 r/min, weight 48 kg

Terminal box Lubrication


Cable lugs are used for secure connections. The The motors have closed bearing housings and the
spacious terminal box makes connecting the bearings are lubricated for life. Nipples for lubrication
motor quick and easy. Cables can enter from in service can be fitted.
the left or the right.

Bearing seal, N-end


Bearing seal, D-end The motors are fitted with enclosed 2Z
The motors are fitted with enclosed 2Z bearings as standard. A labyrinth seal
bearings as standard. A V-ring on the shaft protects the bearing from dirt and moisture.
protects the bearing from dirt and moisture.

Bearings
Modern bearings have high load capacity
ISO 9001 certificate
and run silently. The bearing housing was
ABB Motors is certified under the ISO
developed jointly with SKF.
9001 international quality standard. This
makes ABB Motors a reliable supplier
with comprehensive service.

Cooling fan
Insulation The high efficiency of the motor
High-grade insulation and generous means that a smaller, quiter fan can
electrical dimensioning give the be used.
motor a high overload capacity.

Corrosion protection
Effective, strong corrosion protection
Rotor winding means that the motor can be used in all
The rotor winding is made of pressure die- environments.
cast aluminium, a design that provides high
starting capacity and low noise level.
Stator frame
The stator frame is made of pressure die-cast extra
corrosion-resistant aluminium alloy. The motor has great
mechanical strength and a good surface finish.
SE920774
ABB Motors
59-60
Wärtsilä id: VPENC000053 -

The Leader in Motors

ABB Group is the world's leading electrical enginee- service and back up. The hallmarks of its products
ring company supplying expertise and products for are efficiency, robustness and reliability, combined
electric power generation, transmission, and distri- to represent the best value available. Customers the
bution as well as industrial and rail transportation world over rely on ABB Motors as the most solid
markets. ABB supplies a full range of industrial and reliable supplier of electric motors. But above
electric motors, both AC and DC, LV and HV all, ABB Motors values its customers.
meeting the needs of most applications, with
The best value is also enhanced by ABB Motors'
virtually any power rating.
worldwide customer service network guaranteeing
Within the Group, ABB Motors is the world's leading fast delivery, rapid response and local back-up, as
manufacturer of low-voltage induction motors, well as by worldwide ABB Service network support-
having over 100 years experience and a presence in ing the after sales service.
more than 140 countries. ABB Motors' broad
ABB Motors' manufacturing facilities are located in
understanding of customer applications enables it to
Denmark, Finland, Italy, Spain, Sweden, India and
work closely to solve individual problems or to
Mexico. The comprehensive motor stocks at each
supply custom-designed motors for any project – no
of these sites are reinforced by a large and
matter how demanding.
versatile stocks at Central Stock Europe Germany
For customers, this all represents a solid value and and Central Stock Asia, Singapore, and by
commitment revealed in the dependable quality of numerous distribution stocks.
ABB Motor's products and in its unrivalled customer

ABB Automation 61
Wärtsilä id: VPENC000053 -

LV Motors
Manufacturing sites (*) and some of the biggest sales companies.

Australia Finland* Japan Sweden*


ABB Industrial Systems ABB Motors Oy ABB K.K. ABB Motors AB
Pty Limited P.O.Box 633 2-39, Akasaka 5-Chome S-721 70 Västerås
P.O.Box 126 FIN-65101 Vaasa Minato-Ku tel. +46 (0) 21 329 000
Lilydale, VIC 3140 tel. +358 (0) 10 22 4000 Tokyo 107 fax +46 (0) 21 124 103
tel. +61 (0) 3 9735 7222 fax +358 (0) 10 22 47372 tel. +81 (0) 3 556 38605
fax + 61 (0) 3 9735 7282 fax +81 (0) 3 556 38615 Switzerland
France ABB Normelec AG
Austria ABB Industrie Korea Badenerstrasse 790
ABB Industrie 15, rue Sully ABB Industrial Systems Co.Ltd. Postfach
& Gebäudesysteme GmbH F-69153 Décines Charpieu Oksan Bldg, 12 Fl, CH-8048 Zürich
Wienerbergstrasse 11 B Cedex 157-33, Samsung-dong, tel. +41 (0) 1 435 6666
A-1810 Wien tel. +33 (0) 472 054 040 Kangnam-Ku, fax +41 (0) 1 435 6603
tel. +43 (0) 1 601 09 0 fax +33 (0) 472 020 345 Seoul 135-090
fax +43 (0) 1 601 09 8305 tel. + 82 2 528 2327 Taiwan
Germany fax.+ 82 2 528 3490 Asea Brown Boveri Ltd
Belgium ABB Automation Products P.O.Box 81-54
Asea Brown Boveri S.A.-N.V. GmbH Mexico* Taipei
Hoge Wei 27 P.O.Box 10 02 61 ABB Sistemas, S.A. de C.V. tel. +886 (0) 2 579 9340
B-1930 Zaventem D-68002 Mannheim P.O.Box M-2434 fax + 886 (0) 2 577 9434
tel. +32 (0) 2 718 6311 tel. +49 (0) 621 3810 06000 Mexico D.F.
fax +32 (0) 2 718 6657 fax +49 (0) 621 381 6820 tel. +52 5 328 1400 Thailand
fax +52 5 328 1694 ABB Limited
Brazil Hong Kong 5th Building, 322 Moo 4
Asea Brown Boveri Ltda Asea Brown Boveri Ltd The Netherlands Bangpoo Industrial Estate Soi 6
P.O.Box 00975 3 Dai Hei Street ABB Systemen B.V. Sukhumvit Road, Prekasa,
06020-902 Osasco -SP Tai Po Industrial Estate P.O.Box 2714 Muang, Samutprakarn 10280
tel. +55 (0) 11 704 9111 Tai Po New Territories NL-3000 CS Rotterdam tel. +662 (0) 709 3346
fax +55 (0) 11 702 1991 Hong Kong tel. +31 (0) 10 407 8879 fax +662 (0) 709 3765
tel. +852 292 938 38 fax +31 (0) 10 407 8345
Canada fax +852 292 935 05 The United Kingdom
Asea Brown Boveri, Inc. New Zealand ABB Industrial Systems Ltd
200 Chisholm Dr., India* ABB Service Division 9 The Towers, Wilmslow Road
Milton, Ontario L9T 5E7 Asea Brown Boveri Ltd P.O.Box 22167 Didsbury
tel. +1 905 875 4500 P.O.Box 16 Otahuhu, Auckland Manchester, M20 2AB
fax +1 905 875 0077 Faridabad 121 001 tel. + 64 (0) 9 276 6016 tel. +44 (0) 161 445 5555
tel. +91 (0) 129 233 313 fax + 64 (0) 9 276 1303 fax +44 (0) 161 448 1016
China* fax +91 (0) 129 234 288
ABB Yuejin Motors (Shanghai) Norway USA
Company Limited Indonesia ABB Industri AS ABB Automation Inc.
8 Guang Xing Rd.,Rong Bei P.T. Abdibangun Buana P.O.Box 6540 Rodelökka AC Motors
Town, Songjiang County, P.O.Box 3781 N-0501 Oslo 5 P.O.Box 372
Shanghai 201613 Jakarta 10002 tel. +47 22 872 000 Milwaukee
tel. +86 21 5778 0988 tel. +62 (0) 21 314 9115 fax +47 22 872 541 WI 53201-0372
fax +86 21 5778 1364 fax +62 (0) 21 315 3963 tel. +1 262 785 8364
Singapore fax +1 262 785 8628
Chile Ireland Asea Brown Boveri Pte Ltd
Asea Brown Boveri S.A. Asea Brown Boveri Ltd P.O.Box 95 Venezuela
P.O.Box 581-3 Components Division Pasir Panjang Post Office Asea Brown Boveri S.A.
Santiago Belgard Road Singapore 9111 P.O.Box 6649
tel. +56 (0) 2 5447 100 Tallaght, Dublin 24 tel. +65 775 3777 Carmelitas,
fax +56 (0) 2 5447 405 tel. +353 (0) 1 405 7300 fax +65 778 0222 Caracas 1010A
fax +353 (0) 1 405 7327 tel. +58 (0) 2 238 2422
Denmark* Spain* fax +58 (0) 2 239 6383
ABB Motors A/S Italy* ABB Motores S.A.
Petersmindevej 1 ABB Industria S.p.a. P.O.Box 81
DK-5000 Odense C Motor Division E-08200 Sabadell
tel. +45 66 147 096 Viale Edison 50 tel. +34 93 728 8500
fax +45 65 912 912 I-20099 Sesto S. Giovanni, fax +34 93 728 8554
Milano
Waasa Graphics, 99-10/10000, Printed in Finland

tel. +39 02 262 321


fax +39 02 262 32723

ABB Motors
Marketing Communications
P.O.Box 633
FIN-65101 Vaasa Finland
tel. +358 (0) 10 22 4000
fax +358 (0) 10 22 43575
www.abb.com/automation
Catalogue BU/M2AA GB 99-10

You might also like