2.2 PREREQUISITE
The need to signal in advance possible leakages of the dedusting system avoiding high costs of environmental reclamation
and of plants stop-overs brought, since a long time, to the use of electronic equipments dedicated to a better environmental
safeguard. With the use of these devices it is possible to signal any failure that can produce dangerous emissions in the
atmosphere which are symptom of breakdown in the dedusting plant. Especially, it is possible to control any breaks of the
filtering surfaces, broken bags or cartridges.
The use of TC probes allows therefore to identify the dust particles which are present in the gases that go through the filter
due to any breaks or failures of the bags or cartridges where the quantities of dusts to remark are considerable 100÷400
For a correct functioning of the TC probe, the cartridges or the bags must be mounted in a vertical position.
The TC probe is seldom used for the continuous monitoring of the dustiness degree present in the discharge duct of the
gases in the atmosphere.
The above-mentioned use entails a more complicated calibration and a deep knowledge of the device.
The signal generated by the TC probe depends on the type of material analyzed, the speed of the gas in the duct, the
probe’s length and the density of the particles in the duct.
2.5 OPERATION
The TC probe notes the passage of particles which are present in the gases by turning this physical phenomenon into an
electric signal 4÷20 mA proportional to the dustiness degree.
A rotary switch located inside the head of the probe (SW 21) allows to change the amplification of the exit signal in order to
permit a correct use of the TC probe in the most part of the dedusting systems.
The output signal (4÷20 mA) can be adjusted to program the activation of any alarms when the dust emissions overtake
the values which have been set according to the law restrictions allowed.
4.2 For connections to PLC or to other devices please use the provided units with galvanically isolated entry.
4.3 For the electrical connections use antiflame shielded cable 3 x 0,75 mm²
4.4 Remove the TC probe in case of electric weldings on the support structure of it and during the maintenance.
4.5 Pretect the 'head' of the probe against the direct exposure to sun light.
4.6 Every kind of operation on TC probe must be done without dust in the air and with supply voltage Off
4.7 A remarkable quantity of rain or water in the sampled gases could distort the reading of the signal.
4.8 For supply voltages, cabling and voltages applicable to the relay contacts, follow the current rules
4.9 The lack of application of existing rules and standards of installation and safety exonerate the manufacturer of
responsibility.
4.10 Insert a fast 200 mA fuse on the supply voltage according to IEC / EN 60127, if not connected to the same
equipment manufacturer.
6.4 FASTENING
The standard BS40 flange is a muff male thread of 1¼ GAS with 35 mm
hole.
BS40 is fixed to the duct by means of a welding on the same axis where
the 35mm hole has been made. See the picture.
When the fixing operation of the probe is finished, introduce the TC
probe.
The probe is fixed by closing the 1¼ GAS nut.
In case of high temperatures, consider longer flanges (see the picture)
6.6 MAINTENANCE
The TC probe does not require a particular maintenance.
Could be necessary polish up with a rag soaked of detergent (alcohol,
gasoline etc.) the sensitive part of the probe (inside pole) without
particular precautions.
The necessity to clean the probe should be checked after 6 months of
operation or more frequently in case of gas with high umidity that could
create deposits and consequently provoke alterations to the operation of
the probe.
7.1 PROBE CALIBRATION
7.3 CALIBRATION FOR SIMULATION (SEE PRACTICAL EXAMPLE CALIBRATION FOR SIMULATION 7.8)
The calibration of the probe is recommended after a certain period of operation of the plant. The above mentioned period is
necessary to allow the filtering material to reach the typical characteristics of the functioning (filter partially dirty).
In order to calibrate the STC signal, it is essential that the sampling duct contains a measurable quantity of dust.
In default of dust, it is impossible to proceed with the calibration.
The STC signal must be calibrated in order to cover the whole range of emissions.
In order to proceed with the calibration, the probe must be connected to an instrument that detects the 4÷20mA output signal.
1. Without dust emissions, the value must be 4mA (value pre-determined by the calibration from the manufacturer’s laboratory).
2. With the maximum value of emissions estimated, the signal must be around 14÷18 mA.
In practice, if according to law regulations for certain types of material the maximum level of emissions allowed is equal to 20
mg/m3, the STC signal must be adapted to this value in the presence of maximum emissions.
You can get this calibration by acting on the rotary switch present inside the head of the probe (SW21).
By leaving a margin of 20÷30 % against the maximum value allowed, you can consider that: 0÷20 mg/m3 = 4÷17 mA.
Over 20 mA the STC signal saturates by making insignificant the higher values of dustiness.
This fact does not constitute a problem, since the goal of this application is to control by means of an alarm threshold that the
emission limits envisaged by the law are not overtaken.
The STC signal generated is handled by electronic equipments (ESA sequencers, PLC, PC) that convert it into a digital value.
The digital value can easily be adapted to the value of the quantity of dust present in the duct.
7.5 SENSITIVITY
The TC probe, by triboelectric effect generates a STC electric signal which is function of 4 parameters:
1 Length of the probe
2 Speed of the gases in the sampling duct
3 Type of material present in the smokes
4 Density of dust
The degree of sensitivity of the probe means the possibility to convert the value of the T-E signal (source) in a certain STC
4÷20mA electric signal that can be used by the various equipments connected to it.
The ratio KTC between the two entities is called SENSITIVITY: STC = KTC x T-E.
8.1 WARRANTY
The warranty lasts 4 years. The company will replace any defective electronic component, exclusively at our laboratory, unless
otherwise agreed, upon the Company's prior consent.
WARRANTY EXCLUSION
The ATEX certification decade in case of every type of modifications of the original device that are not done by the manifacturer
All the electrical wiring must be done according to the Europen rule EN 60079-14
In case of faulty that does not depend only to the fuse, switch off immediately the supply voltage and contact the supplier. The
reparation of the device must be done only in our laboratory and the device must be sent with the enclosure to our factory.
In case of application of cable glands by the final user, The company does not assume any responsibility. Use only cable glands
IP65 ATEX certified with same or superior certification of the device and type ISO R/68.
The fixing holes must be done with the right diameter indicated for that cable gland.
With the purpose to avoid the entry of dust inside the equipment through the pneumatic connections for the reading of the dP,
insert on such lines an opportune systems for dusts blocking.
3D Category - Dust
declare that the DoC is issued under our sole responsibility and belongs to the following product:
The object of the declaration described above is in conformity with the relevant Union harmonisation legislation
L'oggetto della dichiarazione di cui sopra è conforme alla pertinente normativa di armonizzazione dell'Unione
Directives 2014/30/UE and 2011/65/UE
Direttiva 2014/30/UE e 2011/65/UE
Directives 2014/34/UE / Direttiva 2014/34/UE
The following harmonised standards and technical specifications have been applied:
Riferimento alle pertinenti norme armonizzate utilizzate
EN 60730-1 2011
EN 50581 2012
EN 60079-31 2014