PVCOUPLERESSSEAU Project - VC0-Report
PVCOUPLERESSSEAU Project - VC0-Report
PVCOUPLERESSSEAU Project - VC0-Report
Project: PVCOUPLERESSSEAU
Variant: Nouvelle variante de simulation
No 3D scene defined, no shadings
System power: 1600 Wp
La Gazelle - Tunisie
Author
Project: PVCOUPLERESSSEAU
Variant: Nouvelle variante de simulation
PVsyst V7.2.6
VC0, Simulation date:
31/10/23 13:25
with v7.2.6
Project summary
Geographical Site Situation Project settings
La Gazelle Latitude 36.90 °N Albedo 0.20
Tunisie Longitude 10.19 °E
Altitude 8m
Time zone UTC+1
Meteo data
La Gazelle
Meteonorm 8.0 (1991-2000), Sat=34 % - Synthétique
System summary
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters
Nb. of modules 4 units Nb. of units 1 Unit
Pnom total 1600 Wp Pnom total 1500 W
Pnom ratio 1.067
Results summary
Produced Energy 2552 kWh/year Specific production 1595 kWh/kWp/year Perf. Ratio PR 84.06 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 4
Loss diagram 5
Special graphs 6
PVsyst V7.2.6
VC0, Simulation date:
31/10/23 13:25
with v7.2.6
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 31 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
PV Array Characteristics
PV module Inverter
Manufacturer AEG Manufacturer INVT Solar technology
Model AS-M1443-H-400 Model MG1K5TL (1.5kw)
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 400 Wp Unit Nom. Power 1.50 kWac
Number of PV modules 4 units Number of inverters 1 unit
Nominal (STC) 1600 Wp Total power 1.5 kWac
Modules 1 String x 4 In series Operating voltage 100-410 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.07
Pmpp 1460 Wp
U mpp 149 V
I mpp 9.8 A
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 253 mΩ Loss Fraction -0.5 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.2.6
VC0, Simulation date:
31/10/23 13:25
with v7.2.6
Main results
System Production
Produced Energy 2552 kWh/year Specific production 1595 kWh/kWp/year
Performance Ratio PR 84.06 %
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst V7.2.6
VC0, Simulation date:
31/10/23 13:25
with v7.2.6
Loss diagram
1684 kWh/m² Global horizontal irradiation
+12.6% Global incident in coll. plane
PVsyst V7.2.6
VC0, Simulation date:
31/10/23 13:25
with v7.2.6
Special graphs
Diagramme d'entrée/sortie journalier