PVCOUPLERESSSEAU Project - VC0-Report

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Version 7.2.

PVsyst - Simulation report


Grid-Connected System

Project: PVCOUPLERESSSEAU
Variant: Nouvelle variante de simulation
No 3D scene defined, no shadings
System power: 1600 Wp
La Gazelle - Tunisie

Author
Project: PVCOUPLERESSSEAU
Variant: Nouvelle variante de simulation

PVsyst V7.2.6
VC0, Simulation date:
31/10/23 13:25
with v7.2.6

Project summary
Geographical Site Situation Project settings
La Gazelle Latitude 36.90 °N Albedo 0.20
Tunisie Longitude 10.19 °E
Altitude 8m
Time zone UTC+1

Meteo data
La Gazelle
Meteonorm 8.0 (1991-2000), Sat=34 % - Synthétique

System summary
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Unlimited load (grid)
Tilt/Azimuth 31 / 0 °

System information
PV Array Inverters
Nb. of modules 4 units Nb. of units 1 Unit
Pnom total 1600 Wp Pnom total 1500 W
Pnom ratio 1.067

Results summary
Produced Energy 2552 kWh/year Specific production 1595 kWh/kWp/year Perf. Ratio PR 84.06 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 4
Loss diagram 5
Special graphs 6

31/10/23 PVsyst Licensed to Page 2/6


Project: PVCOUPLERESSSEAU
Variant: Nouvelle variante de simulation

PVsyst V7.2.6
VC0, Simulation date:
31/10/23 13:25
with v7.2.6

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 31 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PV Array Characteristics
PV module Inverter
Manufacturer AEG Manufacturer INVT Solar technology
Model AS-M1443-H-400 Model MG1K5TL (1.5kw)
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 400 Wp Unit Nom. Power 1.50 kWac
Number of PV modules 4 units Number of inverters 1 unit
Nominal (STC) 1600 Wp Total power 1.5 kWac
Modules 1 String x 4 In series Operating voltage 100-410 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.07
Pmpp 1460 Wp
U mpp 149 V
I mpp 9.8 A

Total PV power Total inverter power


Nominal (STC) 2 kWp Total power 1.5 kWac
Total 4 modules Nb. of inverters 1 Unit
Module area 8.1 m² Pnom ratio 1.07

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 253 mΩ Loss Fraction -0.5 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses Strings Mismatch loss


Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel AR coating, n(glass)=1.526, n(AR)=1.290

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000

31/10/23 PVsyst Licensed to Page 3/6


Project: PVCOUPLERESSSEAU
Variant: Nouvelle variante de simulation

PVsyst V7.2.6
VC0, Simulation date:
31/10/23 13:25
with v7.2.6

Main results
System Production
Produced Energy 2552 kWh/year Specific production 1595 kWh/kWp/year
Performance Ratio PR 84.06 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh ratio
January 68.5 28.82 9.88 106.5 104.8 156.7 150.9 0.885
February 85.7 38.32 10.56 117.7 115.8 172.3 166.0 0.882
March 131.1 64.44 14.20 156.4 153.4 224.9 217.3 0.868
April 163.7 69.98 17.40 175.9 172.3 247.4 238.7 0.848
May 201.8 86.42 21.52 197.6 193.1 273.1 263.8 0.835
June 214.0 84.81 25.86 199.7 194.9 270.4 260.9 0.817
July 227.3 78.31 29.34 216.0 211.0 287.0 277.5 0.803
August 196.3 78.17 28.93 202.7 198.5 271.1 262.0 0.808
September 146.9 64.92 24.56 168.6 165.1 231.2 223.2 0.827
October 111.5 47.52 21.30 144.6 142.3 201.9 194.9 0.842
November 75.0 35.17 15.86 112.0 110.0 161.4 155.4 0.867
December 62.5 30.41 11.53 99.5 97.8 146.7 141.2 0.887
Year 1684.2 707.30 19.30 1897.2 1859.1 2644.0 2551.8 0.841

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

31/10/23 PVsyst Licensed to Page 4/6


Project: PVCOUPLERESSSEAU
Variant: Nouvelle variante de simulation

PVsyst V7.2.6
VC0, Simulation date:
31/10/23 13:25
with v7.2.6

Loss diagram
1684 kWh/m² Global horizontal irradiation
+12.6% Global incident in coll. plane

-2.01% IAM factor on global

1859 kWh/m² * 8 m² coll. Effective irradiation on collectors

efficiency at STC = 19.79% PV conversion

2975 kWh Array nominal energy (at STC effic.)


-0.60% PV loss due to irradiance level

-8.15% PV loss due to temperature

+0.50% Module quality loss

-2.10% Mismatch loss, modules and strings

-1.06% Ohmic wiring loss


2644 kWh Array virtual energy at MPP

-3.35% Inverter Loss during operation (efficiency)

0.00% Inverter Loss over nominal inv. power


0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
-0.14% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
2552 kWh Available Energy at Inverter Output
2552 kWh Energy injected into grid

31/10/23 PVsyst Licensed to Page 5/6


Project: PVCOUPLERESSSEAU
Variant: Nouvelle variante de simulation

PVsyst V7.2.6
VC0, Simulation date:
31/10/23 13:25
with v7.2.6

Special graphs
Diagramme d'entrée/sortie journalier

Distribution de la puissance de sortie système

31/10/23 PVsyst Licensed to Page 6/6