0% found this document useful (0 votes)
41 views10 pages

Jaket Dan Coil

This document provides specifications and calculations for a heat exchanger. It includes properties for air and a fluid mixture, dimensions for a tank and jacket, and calculations for heat transfer rates, temperatures, pressures, and effectiveness. The calculations determine a heat transfer rate of over 106,000 Btu/hr between the tank containing a fluid mixture at temperatures from 194-260°F and a jacket surrounded by air at temperatures from 95-122°F.

Uploaded by

Achmad Fadel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views10 pages

Jaket Dan Coil

This document provides specifications and calculations for a heat exchanger. It includes properties for air and a fluid mixture, dimensions for a tank and jacket, and calculations for heat transfer rates, temperatures, pressures, and effectiveness. The calculations determine a heat transfer rate of over 106,000 Btu/hr between the tank containing a fluid mixture at temperatures from 194-260°F and a jacket surrounded by air at temperatures from 95-122°F.

Uploaded by

Achmad Fadel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 10

D tangki = 12.

35 ft Wa=
k air = 1.08 Btu/jam.ft.oF hi =
miu air = 0.7 cp densitas air 63.21 lbm/ft3 ho =
miu air = 1.694 lbm/ft.jam hio =
Cp air = 1 Btu.lbm/jam.oF A luas alir jaket =
jH jaket = 27 delta T lmtd =
jH coil = 450 Uc =
Dj = 14.35 ft Ud =
De = 4.32388664 ft Rd=
Cp campuran = 2.0622 Btu/jam.oF Hd =
k campuran = 0.62 Btu/jam.ft.oF A =
miu campuran = 1.85 lbm/ft.jam
ID/OD = 0.860627178 ft 1btu 1.055
t1 = 95 oF trial tjaket 1
t2 = 122 oF
T1 = 260.6 oF kecepatan 148.52216042148
T2 = 194 oF debit 6231.5655022556
Q= 11220163.32 Kj/jam
10636714.83 btu/jam
koilllll
tube 1.5 in j 450
Dhelix 1 11.115 ft Hio 1500
Dhelix 2 9.2625 ft
Ex surface/lin ft 0.3925 ft2/ft
415561.6044444 kJ.lb/btu jam konversi 393897.2554 lb/jam
27.52682578489 Btu/jam.ft2.oF
7.835675407193 Btu/jam.ft2.oF
1500 Btu/jam.ft2.oF G 9388.08576 lbm/ft2.jam
41.95714285714 ft2 Re 23962.8209
117.6917311147 oF J jaket 27
27.03077810507
23.81243488718 f 12650 psi
0.005 P 14.7 psi
200 ri 7.175 ft
3795.401802364 c 0.0104167 ft
tinggi jaket 94.523231 ft
Kj
ft E 0.8

hc 118.2406597544 Ud 70.801501
Uc 109.6011205518 A 1276.4949
per turn h1 13.71114642857 ft2
per turn h2 11.42595535714 ft2 turn h1 93.099067
turn doble h 50.781309
turn h2 111.71888
Diketahui JAWA
Air Jaket
t1 95 oF Wa 393874.854932 lb/hr
t2 122 oF Debit 6231.21112058 ft3/hr
tav 108.5 oF Aa 0.50511685714 ft2
k air 0.366 Btu/hr.ft.oF (table 4) v 12336.177327 ft/hr
Cp 1 Btu/lb.oF (fig 2) 3.42671592417 ft/s
Densitas 63.21 lb/ft3 Ga 779769.768841 lb/hr.ft2
visco = 0.7 cp (fig 14) Re 23961.4581549
= 1.694 lbm/ft.hr Jh 80 (fig 24)
Campuran ho 937.392750793 Btu/hr.ft2.oF
T1 260.6 oF Tangki
T2 194 oF Wt 77431.381652 lb/hr
Tav 227.3 oF At 119.839107143 ft2
k camp 0.62 Btu/hr.ft.oF Gt 646.127825032 lb/hr.ft2
Cp 2.0622 Btu/hr.oF Re 537278.378378
visco 1.85 lbm/ft.hr hi 218.875465255 Btu/hr.ft2.oF
Densitas 40.57 lbm/ft3 hoi 937.392750793 Btu/hr.ft2.oF
Alat ΔLMTD 117.691731115 oF
ID tangki = 12.35 ft Uc 177.443495903 Btu/ft2.hr.oF
ID tangki 12.35 ft Rd 0.001 (tabel 12)
tebal jaket 0.013 ft Hd 1000
D jaket 12.376 ft Ud 150.70234497 Btu/ft2.hr.oF
De 0.05205473684 ft L. kontak perpan 599.592317138 ft2
Q 11220163.32 Kj/hr Tinggi jaket 12.1873225615 ft
10634621.0832 Btu/hr

Jh Jaket (fig 24)


JAWABAN

Trial spesifikasi pengaduk


L 7 ft
N 500 rev/h

Perhitungan Coil
Diketahui
OD tube 1.5 in
0.125 ft
Ex Surface/lin ft 0.3925 ft2
Dhelix 1 11.115 ft
Dhelix 2 9.2625 ft (tabel 10 BWG 18)
ID tube 0.116666666667 ft
Dhelix average 10.18875 ft
Coil (tube)
Wc 393874.8549319 lb/hr ekstrapolasi
Ac 0.010694444444 ft2 715 0.184691799742
Gc 36829856.56506 lb/hr.ft2 Jh-285 1
Re 2536491.498971
JH 4156.314270587 (fig 24) 3871.3142706 Jh-285
hi 21729.68584783 Btu/hr.ft2.oF
Jh= 4156.314270587
Tangki
Wt 77431.38165195 lb/hr
At 119.8268303571 ft2
Gt 646.1940236687 lb/hr.ft2
Re 537278.3783784
hc atau ho 218.8754652552 Btu/hr.ft2.oF

Perhitungan Turn (helix)


Doble Helix Helix 1
hio 20281.04012464 Btu/hr.ft3.oF hio 20281.040125 Btu/hr.ft3.oF
hio,c 21151.89818422 Btu/hr.ft4.oF hio,c 21079.326679 Btu/hr.ft4.oF
ΔLMTD 117.6917311147 oF ΔLMTD 117.69173111 oF
Uc 216.6337836916 Btu/ft2.hr.oF Uc 216.62614538 Btu/ft2.hr.oF
Rd 0.001 (tabel 12) Rd 0.001 (tabel 12)
Hd 1000 Hd 1000
Ud 178.0599771233 Btu/ft2.hr.oF Ud 178.05481676 Btu/ft2.hr.oF
A(L.kontak perpan) 507.469279053 ft2 A(L.kontak perpan) 507.48398646 ft2
Per Turn 12.56855089286 ft2 Per Turn 13.711146429 ft2
Turn 40.37611681561 Turn 37.012513075
Anulus (Jaket)-Air

tube (tangki)-Campuran

hitungan Coil

tangki

koil

Helix 2
hio 20281.0401246 Btu/hr.ft3.oF
hio,c 21238.9839902 Btu/hr.ft4.oF
ΔLMTD 117.691731115 oF
Uc 216.64288146 Btu/ft2.hr.oF
Rd 0.001 (tabel 12)
Hd 1000
Ud 178.066123397 Btu/ft2.hr.oF
A(L.kontak perpan) 507.451762834 ft2
Per Turn 11.4259553571 ft2
Turn 44.4121954771
L (length) 0.6
N (speed, r 7500
rho 62.5
viscosity (f 1.0648
k (table 4) 0.38
c 1
ID for 12 in 1.0075
W 32600
Rd 0.005
height 0.833333

Rej = (𝑁𝐿^2 𝜌)/𝜇

158480.5
2928.535

𝑐𝜇/𝑘 2.802105

𝑐𝜇/𝑘 1.409813

hi = 560.5999
hio steam i 1500
Uc = 408.085
hd = 200
Ud = 134.2197

A= 3.433111

Dt LMTD = 70.74788
L (length) 1.339
N (speed, r 13230.72
rho 57.7
viscosity (f 0.462
k (table 4) 0.0884
cp 0.661
ID for 12 in 4.017
Q 408816.3
Rd 0.002
Δt 50
turns 5.45

bedakke turns tabel 11, delta t


Rej = (𝑁𝐿^2 𝜌)/𝜇

2962637
20627.77

𝑐𝜇/𝑘 3.454548

𝑐𝜇/𝑘 1.511693

hi = 247.041
hio steam i 1500
Uc = 212.108
hd = 500
Ud = 148.9297
turns=phi*dcoil*surface per lin OD
A= 54.90058

Dt LMTD = 50
L
N
p