0% found this document useful (0 votes)
154 views3 pages

SCONI-2000 en

The AKORM Corp. Multi Signal Converter SCONI-2000 can accept multiple input signals including thermocouples, RTDs, mV, voltage, and mA. It features high accuracy conversion via a 16-bit ADC, built-in functions like peak hold, and optional RS485 communication. It provides two isolated outputs that can each be scaled separately and includes input/output checking via its display mode.

Uploaded by

m370550647
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
154 views3 pages

SCONI-2000 en

The AKORM Corp. Multi Signal Converter SCONI-2000 can accept multiple input signals including thermocouples, RTDs, mV, voltage, and mA. It features high accuracy conversion via a 16-bit ADC, built-in functions like peak hold, and optional RS485 communication. It provides two isolated outputs that can each be scaled separately and includes input/output checking via its display mode.

Uploaded by

m370550647
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

AKORM Corp.

Multi Signal Converter SCONI - 2000

󲐀 Order Information

SCONI - 2000 - □ □ - □

󲐀 Input Signals
T/C, RTD
Multi
mV, Volt, mA

󲐀 Output-1 Signals
1 DC 0 ~ 5V
󲐀 Features 2 DC 0 ~ 10V
󲐀 Multiple input signals of T/C, RTD, Volt, mA and 2-wire
3 DC 1 ~ 5V
can be accepted.
4 DC 0 ~ 20mA
󲐀 By adopting high-performing and high-accurate
16 Bit A/D converter, excellent reliability is guaranteed. 5 DC 4 ~ 20mA
󲐀 With various built-in functions such as Peak Hold, this converter 6 DC 1 ~ 5mA
can be applied for various purposes.
R Other
󲐀 RS485 ModBus communication can be installed,
so it is convenient for remote surveillance and control.
󲐀 2 isolated outputs can be installed, and each output 󲐀 Output-2 Signals
can be scaled separately.
1 DC 0 ~ 5V
󲐀 Function of easy input and output signal checking
through display mode selection key is provided as a standard. 2 DC 0 ~ 10V

3 DC 1 ~ 5V

󲐀 Input Type 4 DC 0 ~ 20mA


Sensor Type Symbol Scale 5 DC 4 ~ 20mA
B(PR) TC-B 0 ~ 1800℃
6 DC 1 ~ 5mA
R(PR) TC- R 0 ~ 1750℃
S(PR) TC- S 0 ~ 1750℃ 7 RS-485

K(CA) TC- K -250 ~ 1350℃ R Other


T/C
E(CRC) TC- E -199.9 ~ 700.0℃ N Not used
J(IC) TC- J -199.9 ~ 800.0℃
T(CC) TC- T -199.9 ~ 400.0℃
N(NN) TC-N -250 ~ 1350℃ 󲐀 Power Supply
D-Pt100Ω D-PT -199.9 ~ 800.0℃ X AC 85~264V/(50~60Hz)
RTD
J-Pt100Ω J-PT -199.9 ~ 500.0℃ Y DC 24V(Option)
mV MV -100 ~ 100mV DC
DC Volt 1V 1V -1.0 ~ 1V DC
10V 10 V -10 ~ 10V DC
mA 20MA 4 ~ 20mA
DC mA
2-Wire 20MA 24V/4 ~ 20mA

AKORM Corp. Samcheondong 1Ga 651-2 Wansangu Jeonjusi Jeonbuk 560-807 KOREA
www.akorm.com Tel : +82-63-228-0560 Fax : +82-63-228-0561 E-mail : [email protected]
AKORM Corp.
Multi Signal Converter SCONI - 2000

󲐀 Specifications 󲐀 Functions
Item Specification
󲐀 Input and Output Data Checking
Volt Type : 400㏀, mA Type : 250Ω Input and output signal value(0~100%) checking is always
Input Resistance
Others : 1㏁ possible by simply setting built-in mode key even without
using testers or avometers.
Source Resistance PT100Ω : 30Ω/Line, Others : 1㏀/Line
Sensor Power DC 24V/80㎃, ± 0.5% 󲐀 Display Scaling(mV, Volt and mA)
To set up display(PV) value according to the changes of
Response Time 100ms(Volt, mA) , 200ms(T/C, RTD) scale and input range.
RS 485
(4800, 9600, 19200 and 38400 bps)
󲐀 Sensor Compensation
Communication To add up or subtract compensation value from measured
ID(Address) Allocation : 01 ~ 99 values when zero point shifted due to a long time use of
and Speed sensor or an undesirable tolerance occurs due to a long
Data Type : 8 Bit Data,
(ModBus) sensor lead.
Even Parity 1-Stop
Protocol : ModBus 1.1 RTU 󲐀 Functioning(mV, Volt, mA)
Limit
Filtering NONE(FAST) 4, 8, 16 and 32 To display zero(0) in case input signal disconnected.
Allowable Tolerance 0.2% of Span at 23℃ Linear
To set up display to ‘ - ‘.
Linearity 0.1% of Span Root Square
4~20mA DC(0 ~ 600Ω) To display square root value out of output signals.
Load Resistance Square Root
0~10V DC(1㏀ or more)
To display squared values of square root input signals.
More than 100㏁ (1000V DC)
Isolation Resistance 󲐀 Filtering
among Input and Output
None(Fast), 4, 8, 16 and 32
AC 1500V/min To Filter an undesirable response time or noise in the field.
Withstand Voltage
between Input, Output and Power
󲐀 Communication
AC 85~264V(50/60Hz), Max. 10VA Remote surveillance is possible by communicating with
Power Supply
DC 24V ±10%, Max. 200mA or 5VA computer when output RS485(ModBus) is installed.
Ambient Temperature -10 ~ 60℃
󲐀 Output Scaling
Ambient Humidity 10 ~ 90% To change output value of current and voltage according to
Weight Appr. 300g(AC/DC) output scale.

Material/Color Non-Flammable ABS / Black 󲐀 More Useful Functions


8-Pin : W 48 x H 80 x D 122 (mm) - Checking High or Low Peaks for Input signals is possible.
Dimensions - Function of external Hold and Reset(Option).
11-Pin : W 48 x H 80 x D 130 (mm) - Setting up High and Low Peaks for present value.
Mounting Type Wall or DIN Rail
󲐀 Terminal Connection

AKORM Corp. Samcheondong 1Ga 651-2 Wansangu Jeonjusi Jeonbuk 560-807 KOREA
www.akorm.com Tel : +82-63-228-0560 Fax : +82-63-228-0561 E-mail : [email protected]
AKORM Corp.
Multi Signal Converter SCONI - 2000

󲐀 Dimensions

AKORM Corp. Samcheondong 1Ga 651-2 Wansangu Jeonjusi Jeonbuk 560-807 KOREA
www.akorm.com Tel : +82-63-228-0560 Fax : +82-63-228-0561 E-mail : [email protected]

You might also like