RAC Questionnarie
RAC Questionnarie
RAC Questionnarie
Objectives
Numericals
1. A machine working on carnot cycle operates between 305 K and 260 K. Determine the COP when [6]
it is operated as refrigerator, heat pump, and heat engine.
2. A Carnot refrigeration cycle absorbs heat at 270 K and rejects it at 300 K: [6]
1. Calculate COP for this system.
2. If the cycle is absorbing 1130 kJ/min at 270 K, how many kJ of work is required per
second?
3. How many kJ/min will the heat pump deliver at 300 K if it absorbs 1130 kJ/min at 270 K.
3. A cold storage is maintained at -5oC while the surroundings are at 35oC . The heat leakage from [6]
the surroundings into the cold storage is 29 kW. Find the power required to drive the system.
4. A refrigerator using carnot cycle requires 1.25 kW per Tonne of Refrigeration to maintain a [6]
temperature of -30oC. Find the COP of Carnot Refrigerator, Temperature at which the heat is
rejected, and heat rejected per tonne of refrigeration.
5. A refrigerating plant requires to produce 2.5 Tonnes of ice per day at -4oC from water at 20oC . If [6]
the temperature range in the compressor is between 25oC and –6oC, calculate the power required
to drive the compressor. Latent heat of Ice is 335 kJ/kg and specific heat of ice is 2.1 kJ/kg.
6. A carnot refrigeration system has working temperature of -30oC and 40oC. What is the maximum [6]
COP possible? If the actual COP is 75% of the maximum, calculate the actual refrigerating effect
produced per kW/hr.
7. In an ammonia vapour compression refrigeration system, the pressure in the evaporator is 2 bar. [6]
Ammonia at exit to evaporator has dryness 0.85and at entry has dryness 0.19. During compression
work done per kg of ammonia is 150 kJ. Calculate the COP and the volume of vapour entering the
compressor per minute, if the rate of ammonia circulation is 4.5 kg//min. The latent heat and
specific volume at 2 bar are 1325 kJ/kg and 0.58 m3/kg respectively.
8. The temperature limits of an ammonia refrigerating system are 25oC and -10oC. If the gas is 0.91 [6]
dry at the entry to compressor and dry at the exit to compressor. Calculate the COP of the cycle.
9. A vapour compressor refrigeration system works between the pressure limits of 60 bar and 25 bar. [6]
The working fluid is 0.791 dry at the entry to compressor and dry saturated at the exit to
compressor. Determine COP of the cycle, capacity of the refrigerator if the fluid flow at the rate of
5 kg/min.
10. 28 tonnes of ice from and at 0oC is produced per day in an ammonia refrigerator. The temperature [6]
in the range of compressor is from 25oC to -15oC. The vapour is dry and saturated at the end of the
compressor. The vapour at the exit to evaporator is 0.9 dry. Assuming actual COP to be 62% of
the theoretical , calculate the power required to drive the compressor. Following properties of
ammonia are: