Manual User
Manual User
Thank you for choosing our Air Conditioner. Please read this INSTALLATION
HANDBOOK carefully prior to installing and keep it for further reference.
Do not attempt to install, maintain the Air Conditioner by yourself.
Incorrect behaviour may cause fire, electric shock and the unit falling may result in
injury or water leakage. Contact our designated air conditioner service centre and
specialists. The manufacturer shall not assume responsibility for accidents or injury
caused by incorrect behaviour.
This product must not be disposed together with the domestic waste.
This product has to be disposed at an authorized place for recycling
of electrical and electronic appliances.
Installation sketch 2
Installation instructions 3
1
Downloaded from www.Manualslib.com manuals search engine
INSTALLATION SKETCH
Confirm the installation position by the mark of the indoor mounting plate.
or
above
105m above
m 1 55mm
above 250mm
or or
front
back
Above 20mm
right
back left
underside left-back
TO A INDOOR UNIT
above 500mm
abov
e 30 00m
3上
m
A
0mm mvme以
1a0b0o
ve 3
00m
m B
m abo
00m 0mm
ve 5 above 30
abo
m
abo 00m
ve 5 ve 5
0 abo
0mm UNIT
DOOR
TO B IN
Abo
ve 50
0mm A B
Single Split Model
Dual inverter Model
TO A INDOOR UNIT
TO A INDOOR UNIT
Above 500mm
above 500mm
abov m
A mm
e 30 00m 300
0mm ve 3 ve
abo abo
B above 30
0mm
m
00m
m 00m
ve 5 TO B INDOOR UNIT ve 5
abo abo
UNIT
DOOR
TO B IN
abo
ve 5
00m
m
OR abo
ve 5
00m
m
fasten string at the central hole Fasten string at the central hole
at least 250mm
at least 250mm
455mm or more
at least 250mm 155mm or more from sidewall
105mm or more
mounting plate from sidewall from sidewall
105mm or more
from sidewall
Tapping screw plumb
Tapping screw
ST4×25(5) ST4×25(5) mounting plate
plumb
NOTICE: The holes at solid arrow position must be secured to avoid the shake of mounting plate.
When the expansion bolts are used, two holes ( 11×20 or 11×26 ) that the distance
between them is 450mm should be adopted.
45mm
plumb Center of hole( 65mm) Center of hole( 65mm)
NOTICE: Confirm the position of holes, and drill holes on the wall.
3
Downloaded from www.Manualslib.com manuals search engine
fasten string at the central hole at least 250mm fasten string at the central hole
440mm 440mm at least 80mm
at least 140mm at least 180mm at least 120mm
at least 120mm
230mm
¦
40mm
90mm plumb
Pipe hole ¦ 90mm
plumb Pipe hole
Center of hole( 65mm) 120mm Center of hole( 65mm)
NOTICE:
The holes at solid arrow position must be secured to avoid the shake of mounting plate.
When the expansion bolts are used, two holes ( 11×20 or 11×26 ) that the distance
between them is 450mm should be adopted.
Confirm the position of holes, and drill holes on the wall.
2 Wiring
Diagram
Open the front grille;
Remove the screw from electrical box cover, pull the
electrical box cover away from the unit and set aside. Screw
Remove the screw from fastener, pull the fastener
away from the unit and set aside.
Connect the cable. Indoor unit terminal Connecting cable
Replace the fastener and electrical box cover.
NOTE:
The appliance shall be installed in accordance with national wiring regulations.
The appliance must not be installed in the laundry.
The appliance must be installed 2.5m above the floor.
The appliance must be positioned so that the plug is accessible.
For some models whose cooling capacity are above 4600W (17000BTU/h),
an all-pole disconnection device which has at least 3mm separation distance in
all pole and a residual current device(RCD)with the rating of above 10mA shall
be incorporated in the fixed wiring according to the national rule.
ROUTE OF PIPE
If pipe comes out of the right side of the indoor unit, cut part
1 of the unit;
If pipe comes out of the lower-right side of the indoor unit, cut
part 2 of the unit; 1 3
2
If pipe comes out of the left side of the indoor unit, cut part 3
of the unit.
To drain the condensate water easily, the drain hose should be declined downwards.
The following 5 arrangement methods are incorrect.
If you find the drain hose not long enough to connect with the indoor
unit, you can extend it with the hoses in the accessory box. Drain hose
The drain hose through the room must be wrapped up with the special
adiabatic material.
Hose(ID 15cm)
7 Wall sealing and Pipe fastening PVC hard
Use putty to seal the wall hole.
Use clamp (pipe fastener) to secure the pipe at specified position.
5
Downloaded from www.Manualslib.com manuals search engine
INSTALLATION OF THE OUTDOOR UNIT
1 Wiring
Outdoor unit terminal Outdoor unit terminal Outdoor unit terminal
Connecting Connecting
Connecting cable cable
cable
OR
Terminal board
Maintenance
board Outdoor pipe support
(Outdoor pipe support is not required
Piping cover when leading the cable wire from other places).
Maintenance
board
Back wiring
Piping cover
Right wiring
Sponge
Piping cover Ejecting hole
Connecting
Connecting Brown cable Black Brown
Brown Yellow/Green Blue
cable Blue Gray Brown Gray
Blue Blue
Yellow/Green Brown
Black Blue Yellow/Green Plug housing 2
N2 Outdoor unit N2 3 4 R1R2 N2 3 4 Outdoor unit terminal
terminal
Cool only type Heat pump type OR Heat pump type
Cool only type Heat pump type OR Heat pump type OR Heat pump type
Yellow/Green
Brown
Brown
Brown
Brown Blue
Blue
Gray
Black
234
Blue
L1 L2 R1 R2
LN
Blue
Cool only type Heat pump type OR Heat pump type Cool only type Heat pump type
(T3) (T3)
Connecting
Connecting
cable cable Connecting
cable
Blue Power
Yellow/Green source Power
source Black
Brown Black Outdoor
Brown L N L N 2A2B unit terminal L N 2A2B Outdoor
L N 2 Plug housing 2 unit terminal
Outdoor unit terminal Blue Black
Blue Black Yellow/Green Brown Blue
Yellow/Green Brown
Heat pump type Heat pump type Cool only and heat pump type
7
Downloaded from www.Manualslib.com manuals search engine
Notice:
If not include the connect diagram you need, please see the wiring diagram.
If you find the color of connecting cable not comply with the top diagram, please take
real objects as major reference. But the terminal of the same sign must be joint with
the connecting cable of the same color.
The plug housing 1 is connected to the matched receptacle housing of the indoor unit.
The plug housing 2 is connected to the matched receptacle housing of the outdoor unit.
2
If the signal wire has to be bought separately, choose electric wire above 0.75mm.
If not include the connect diagram you need, please see the wiring diagram.
If the interconnection cord for power supply has to be replaced, please see the
following table for reference.
MODEL SPECS (Interconnection cord)
2
2700W(10000BTU/h) 1.0mm
3200W(11000BTU/h) -4000W(15000BTU/h) 1.5mm 2
4500W(16000BTU/h) -8000W(28000BTU/h) 2.5mm 2
8500W(29000BTU/h) -9500W(32000BTU/h) 4.0mm 2
10000W(34000BTU/h) -11000W(38000BTU/h) 6.0mm 2
WARNING:
Please take the electric circuit diagram attached to the indoor/outdoor units as major
reference while installing.
The power wire and signal wire between the indoor/outdoor units must be connected
one by one as per corresponding number on the wiring terminal board.
The connecting cables must be clipped together.
Special cable must be used to connect indoor unit and outdoor unit. It should be ensured
that the terminals are not influenced by external force. Poor connection may cause fire.
The electric box cover must be mounted and secured in position, otherwise fire or electrical
shock may occur because of dust or moisture.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away
from the connecting tube.
All the models shall be connected with the mains which has system impedance limitations.
While installing the unit, please see the following table for impedance information or consult
with the supply authority.(The following information and specifications are subject to change
without prior notice due to continuing research.)
Align the centre of joint in line with that of flare and tighten the nut of connecting pipe
with wrench. ( Adjust the torque by the same method of connecting pipe for indoor unit.)
4 Air exhausting
Screw down the cap of both gas shut-off valve and
liquid shut-off valve as well as the nut of service port.
Use Allen wrench to turn the valve cork of liquid side liquid connecting pipe
at 90 counter-clockwise, and close it after 10 seconds. liquid shut-off valve
Use soapy water to check the gas leakage especially allen wrench
at all joint. If there is no gas leakage, please turn the gas connecting
valve cork of liquid side at 90 counter-clockwise again. pipe
gas shut-off
Press the cork of service port at gas shut-off valve, 10 valve valve nuts
seconds later, when you see foggy gas discharged, that
means inner air is exhausted out. service port
service port cap
Use Allen wrench to turn the valve cork of both liquid
shut-off valve and gas shut-off valve counter-clockwise
until they are completely open and then replace the
valve caps and tighten them.
Notice:
Do not vent refrigerant into atmosphere: refrigerant is a fluorinated greenhouse gas, covered by
Kyoto protocol, with a Global Warming Potential (GWP) =1900(R410A)/1600(R407C)/1700(R22).
Burr Reamer
Outer diameter A(mm)
φ6/φ6.35mm(1/4") 2.0--2.5
φ9/φ9.52mm(3/8") 3.0--3.5
φ12/φ12.7mm(1/2") 3.5--4.0 D A
φ15/φ15.88mm(1/2") 4.0--4.5
9
Downloaded from www.Manualslib.com manuals search engine
6 Adding refrigerant
If the connecting pipe is longer than 7 metres, add refrigerant as needed. (Cool only type) added
amount A=(Lm-7m) 15g/m ; (Heat pump type)added amount A= (Lm-7m) 50g/m. ( A: amount
of added refrigerant, L: the length of connecting pipe)
Exhaust the air as the above-mentioned method. Manifold gauge Pressure meter
Screw the gas shut-off valve to close, connect
Low pressure High pressure
charging hose(low pressure) to the service valve valve valve
and then open gas shut-off valve again.
Connect the refrigerant bottle to the charging hose Charging line
and then convert it.
7 Operation test
Before test operation, wiring safety inspection must be carried out carefully again.
2. Remote controller operation: If the indoor unit sounds like Di, Di when pressing I/O button,
that indicates the air conditioner is under the operation of remote controller. After that, press
every button to test their functions.
3.Check switch operation: Open the front grille and press the check button. Switch on the power
source and then the operation test is activated. If the indicator lamps light up at first and then
go out in succession or the LED window of the indoor unit illuminates at first and then goes out,
the system is under normal operation. If one of the indicator lamps is flashing at all times, or
failure codes are displayed on the LED window of the indoor unit, the system has something
wrong and please check malfunction immediately.