Detail Design of Column
Detail Design of Column
Minumum eccentricity
ex= lx/500+D/30 = 26.4 (IS 456:2000, cl.25.4)
ey= ly/500+B/30 = 26.4
emin= 0.05*D= or 20 which ever is greater
so, ex = 30
ey= 30
FROM ETABS
Pu= 3996.996 KN
Mux= 426.9121 KNm
Muy= 345.5963 KNm
Hence,
Moment due to eccentricity about x ,
Muex = Pu*ex = 119.90988 KNm
Muey = Pu*ey = 119.9098 KNm
The design moment is greater of moment due to eccentricity and
moment obtained from analysis
δ = 1+3*Pu/(Ag*fck) = 1<1.5
so,
δ=1.5
Design shear strength of concrete = δ*τc = 0.96 N/mm2
Shear capacity of section, ( Vuc ) = 312.192 KN
As Vuc>Vu , minimum shear reinforcement is to be provided in the
form of lateral ties.
Dk= 536 mm
Ash= 490.8594 mm2
Ak = 22527.36 mm
Ag= 600^2 mm2
Ash = 0.18sDkFck/Fy(Ag/Ak-1)
Or, 490.8594 = 0.18*S*536*(25/500)*(600^2/22527.36-1)
or, S = 175.65 mm>100mm
Spacing of hoop should be less than 100mm and minimum of 1/4 of B or D
whichever is less. But, the spacing need not be less than 75mm. (IS 13920:2000
Cl. 7.4.6)
Hence, provide 8mm diameter links @ 100mm c/c for a distance 600 mm on
either side from the joint and 8 mm diameter lateral ties @300mm c/c in
central portion.