Design of Mat Foundation
Design of Mat Foundation
CG of load:
X'= Σ(Pi*Xi)/Σ(Pi)
Y'= Σ(Pi*Yi)/Σ(Pi)
Eccentricity,
ex=X-X'
ey= Y-Y'
So,
X'= 23.349
Y'= 7.086
and,
ex=0.032
ey= 0.229
Lx(b)= 46.178
Ly(d)= 14.174
A= 654.527 m2
Mxx= ΣP*ey 23872.70065 KNm
Myy= ΣP*ex 3295.369159 KNm
Calculation of moment of inertia
Ixx = bd^3/12= 10957.99653
Iyy = db^3/12= 116309.862
Mxx/Ixx = 2.178564355
Myy/Iyy = 0.028332672
Soil pressure at different points can be calculated as below:
Stress = ΣP/A +-Mxx*X/Ixx+-Myy*Y/Iyy
Bending moment is obtained by coefficient 1/10 and L as distance between column centre
Bending moment is obtained by coefficient 1/10 and L as distance between column centre
MAX B M Value Unit
1.Beam 1-1 497.4690525 kNm
2.Beam 2-2 497.7940915 kNm
3.Beam 3-3 494.1825479 kNm
4.Beam 4-4 497.204206 kNm
So we get maximum factored BM for strip L-L
i.e Max BM = 758.431 kNm
from Bending Moment criteria
Limiting moment of resistance for M25 grade concrete = 0.138fck bd²
Therefore,
depth required = 605.3030542 mm
Adopt d= 800 mm
Depth Provided is sufficient against bending and two way shear consideration.
Calculation of reinforcement
maximum moment = 758.431 KNm
Minimum Ast = 0.15%of area
= 0.15/100*5684616.533
= 8526.92 mm2
From IS 456:2000
BM = 0.87*fy*Ast *(d-Ast*fy/fck*B)
Area of Steel req. = 2271.53 mm2
providing 16mm dia bar,
Area of 1 bar = 201.056 mm2
Spacing = 123.9157748 mm
CHECK
spacing should be <= 3d and <=300 , 3d= 3*800 = 2400 mm
summary
Dimension of footing = 4 m* 4 m
effective depth of footing = 800 mm
overall depth of footing = 800+65 = 865 mm
Reinforcement Along Depth and Breadth = 16 mm dia bar @ 125 mm C/C