Vane Motors - 21,6 To 37,5 CM /R (1.32 To 2.29 in /R) : Characteristics Efficiency

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Vane Motors – 21,6 to 37,5 cm3/r

(1.32 to 2.29 in3/r)

Characteristics Efficiency
An economical, efficient and compact means of applying Optimum running clearances and hydraulic balance assure
variable speed, rotary hydraulic power, these motors have sustained high efficiency over the life of the motor.
variable horsepower (constant torque) characteristics. They
can be stalled under load without damage when protected by Smooth Operation
a relief valve. Inertia of rotating parts is low ... parts are symmetrical, provid-
ing dynamic balance and freedom from vibration.
Hydraulic Balance
Two internal inlet chambers are diametrically opposed as are
two outlet chambers. This construction eliminates bearing
loads resulting from pressure, a major cause of wear in de-
signs without this feature.

98 EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011
Operating Specifications

Model Torque Displ. Maximum torque Maximum speeds Approx.


series Nm/6,9 bar cm3/r Nm (lb. in.) @ & pressures weight
(lb. in./100 psi) (in3/r) max. pressure lbs.

M2U 2,0 (18) 21,6 (1.32) 38,4 (340) 2800 r/min @ 138 bar (2000 psi) 7,7
2,8 (25) 25,4 (1.55) 46,3 (410) 2500 r/min @ 138 bar (2000 psi) (17)
4,0 (35) 37,5 (2.29) 67,8 (600) 2000 r/min @ 138 bar (2000 psi)
M2–210 2,8 (25) 24,7 (1.51) 46,3 (410) 2200 r/min @ 138 bar (2000 psi) 9,5
4,0 (35) 35,4 (2.16) 56,5 (500) 1800 r/min @ 121 bar (1750 psi) (21)

Model Codes
M 2 U - 1 S 35 S - 1 C 10 L

1 2 3 4 5 6 7 8 9 10 11

1 Vane motor 6 Ring size – torque 9 Outlet position


(lb. in./100 psi) (Viewing cover end)
18, 25 and 35 A – Outlet port opposite inlet
2 Series C – Port connections inline

7 Outlet port
3 Uni-directional rotation S – 1-5/16 – 12 st. thd. 10 Design
Subject to change. Installation
dimensions remain the same for
4 Mounting 8 Shaft type designs –10 through –19.
1 – 2-bolt flange 1 – Straight keyed
3 – Threaded
11 – Splined 11 Rotation
5 Inlet port L – Left hand (counterclockwise)
S – 1-5⁄16 – 12 st. thd. Omit for right hand (clockwise)

M 2 - 2 1 0 - 35 - 1 C - 13

1 2 3 4 5 6 7 8 9

1 Vane motor 5 Mounting 8 Cover position


0 – 2 bolt flange (Viewing cover end)
A – Cover port opposite body port
2 Series (bi-directional rotation) B – Cover port 90 CCW from body port
6 Ring size – torque C – Port connections in line
lb. in./100 psi D – Cover port 90 CW from body port
3 Series frame size 25 and 35

9 Design
4 Porting 7 Shaft type Subject to change. Installation dimen-
1-3⁄4 NPT both ports 1 – Straight keyed sions remain the same for designs –10
3 – Threaded through –19.
6 – Straight keyed (stub)
11 – Splined

EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011 99
Installation Dimensions

M2U series
Dimensions in millimeters (inches)
Shaft options shown on page 101.
Dimensions OUTLET PORT
Model A B 1.3125-12 UN-2B THD.
FOR SAE HYDRAULIC FITTING
M2U–1S18S-1C10 129,8 (5.11) 105,4 (4.15) USED WITH 1” O.D. TUBING

M2U–1S25S-1C10 136,1 (5.36) 111,8 (4.40) #1 SHAFT


M2U–1S35S-1C10 141,0 (5.55) 116,6 (4.59)

INLET PORT
1.3125-12 UN-2B THD.
FOR SAE HYDRAULIC FITTING
USED WITH 1” O.D. TUBING

12,7 (.50)

A
CLOCKWISE
B
67,6 Ø 11,1 (.438) ROTATION
52,3 52,3 2 HOLES
34 (2.66)
(2.06) (2.06)
(1.34) 4,1 (.16)
C 4,8 (.1875)
41,1
(1.62) KEY
62,0
(2.44) 53,8 21,13/21,00
(.832/.827)
(2.12)
Ø 82,55/82,50
124,0 Ø 19,05/19,02 (3.250/3.248)
(4.88) (.750/.749)

A Ø 82,55/82,50
47,8 (1.88) R.
(3.250/3.248)
ARROW ON RING INDICATES ROTATION
Ø 130,0 (5.12)
“35 ” INDICATES LB. IN. TORQUE PER 100 PSI

M2-200 series
Dimensions in millimeters (inches)
Shaft options shown on page 101. CONNECTION “K”
3/4 ” NPT
CONNECTION “L”
3/4 ” NPT
Fluid supply to connection “L ” provides
clockwise shaft rotation, viewed from
shaft end.
Fluid supply to connection “K ” provides
counterclockwise shaft rotation.

12,7 (.50)
4,1 (.16)
CLOCKWISE
106,4 149,9 67,6
#1 SHAFT ROTATION
(4.19) (5.90) (2.66)
53,1 4,788/4,7625
71,8 37,3 (.1885/.1875) Ø 106,27/106,47
(2.09) 41,1 (4.184/4.192)
C (2.81) (1.47) KEY
(1.62) Ø 95,3
(3.75)
106,4 21,13/21,00
(4.19) (.832/.827) Ø 82,55/82,50
(3.250/3.248)
B D 122,9
53,1 (4.84) Ø 19,05/19,02
50,8 (2.00)
(2.09) (.750/.749)

32,5 (1.28)
A 53,1
DRAIN CONNECTION (2.09)
3/8 “ PIPE THD .438 DIA – 2 HOLES
FOR MOUNTING 130,0
(5.12)

100 EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011
Optional Shafts

M2U & M2-200 series


Dimensions in millimeters (inches)

70,6 74,7
(2.78) (2.94)
Ø 26,9 (1.06) 31,8 (1.25) 50,8
(2.00)
16,8 #13 WOODRUFF KEY 37,3 FULL DEPTH
(.66) (1.47) OF SPLINE
9,7 (.38)
INVOLUTE SPLINE
Ø 26,9 6,4 (.25) 16/32 D.P.
FLAT ROOT – 11 TEETH
(1.06) 30 PRESSURE ANGLE
31,8 (1.25) HEX

26,08/25,82 Ø 19,08/19,02
(1.0267/1.0167) (.751/.749)
Ø 23,83/23,81 Ø 18,62/18,47
(.9380/.9375) .875-18 #2 THD. (.733/.727)

No. 3 threaded shaft No. 11 splined shaft

NOTE:
Nut torque 169,5 Nm (125 lb. ft.)

M2-200 series
Dimensions in millimeters (inches)
NOTE: No. 1 keyed shaft is shown
on page 100.
31,8
(1.25)
12,7
(.50) #9 WOODRUFF KEY

21,25/21,00
(.8368/.8268)

Ø 19,01/19,00
(.7485/.7480)

6,4 (.25) 18,3 (.72)

12,7 (.50) FLAT

No. 6 straight stub shaft

EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011 101
Typical Performance

M2U Series
Performance Constants:
Oil temp. 49° C (120° F), viscosity
32 cSt (150 SUS) @ 38° C (100° F)

18 LB. IN. RING 25 LB. IN. RING


138 bar (2000 psi) 138 bar (2000 psi)
68 (18) 103 bar (1500 psi) 76 (20)
103 bar (1500 psi)
69 bar (1000 psi) 69 bar (1000 psi)
34 bar (500 psi) 34 bar (500 psi)
61 (16) 68 (18)
Volume required – L/min (USgpm)

52 (14) 61 (16)

45 (12)

Volume required – L/min (USgpm)


52 (14)

38 (10)
45 (12)

30 (8)
38 (10)

23 (6)
30 (8)
15 (4)
23 (6)
8 (2)
15 (4)
0
0 400 800 1200 1600 2000 2400 2800
8 (2)
Speed – r/min

0
0 400 800 1200 1600 2000 2400
Torque – Nm (lb in)

45,2 (400) Speed – r/min


138 bar (2000 psi)
33,9 (300) 103 bar (1500 psi)
22,6 (200)
69 bar (1000 psi)
11,3 (100) 34 bar (500 psi) 56,5 (500)
Torque – Nm (lb in)

0 138 bar (2000 psi)


0 400 800 1200 1600 2000 2400 2800 45,2 (400)
Speed – r/min 33,9 (300) 103 bar (1500 psi)
22,6 (200) 69 bar (1000 psi)
11,3 (100) 34 bar (500 psi)
0
Power – kW (hp)

11,9 (16) 138 bar (2000 psi) 0 400 800 1200 1600 2000 2400
8,9 (12) 103 bar (1500 psi) Speed – r/min
6,0 (8)
69 bar (1000 psi)
3,0 (4)
34 bar (500 psi)
0 14,9 (20)
0 400 800 1200 1600 2000 2400 2800
Power – kW (hp)

11,9 (16) 138 bar (2000 psi)


Speed – r/min
8,9 (12) 103 bar (1500 psi)
6,0 (8) 69 bar (1000 psi)
3,0 (4) 34 bar (500 psi)
0
0 400 800 1200 1600 2000 2400
Speed – r/min

102 EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011
Typical Performance

M2U Series
Performance Constants:
Oil temp. 49° C (120° F), viscosity
32 cSt (150 SUS) @ 38° C (100° F)

35 LB. IN. RING


138 bar (2000 psi)
83 (22)
103 bar (1500 psi)
69 bar (1000 psi)
76 (20) 34 bar (500 psi)

68 (18)

61 (16)
Volume required – L/min (USgpm)

52 (14)

45 (12)

38 (10)

30 (8)

23 (6)

15 (4)

8 (2)

0
0 400 800 1200 1600 2000
Speed – r/min

67,8 (600) 138 bar (2000 psi)


56,5 (500)
Torque – Nm (lb in)

103 bar (1500 psi)


45,2 (400)
33,9 (300)
69 bar (1000 psi)
22,6 (200)
11,3 (100) 34 bar (500 psi)

0
0 400 800 1200 1600 2000
Speed – r/min

14,9 (20) 138 bar (2000 psi)


Power – kW (hp)

11,9 (16)
103 bar (1500 psi)
8,9 (12)
6,0 (8) 69 bar (1000 psi)

3,0 (4) 34 bar (500 psi)

0
0 400 800 1200 1600 2000
Speed – r/min

EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011 103
M2-200 Series
Performance Constants:
Oil temp. 49° C (120° F), viscosity
32 cSt (150 SUS) @ 38° C (100° F)

25 LB. IN. RING 35 LB. IN. RING


61 (16) 138 bar (2000 psi) 76 (20) 121 bar (1750 psi)
Volume required – L/min (USgpm)

103 bar (1500 psi) 68 (18) 103 bar (1500 psi)


52 (14)
69 bar (1000 psi) 69 bar (1000 psi)

Volume required – L/min (USgpm)


45 (12) 34 bar (500 psi) 61 (16) 34 bar (500 psi)

38 (10) 52 (14)
30 (8) 45 (12)
23 (6) 38 (10)
15 (4) 30 (8)
8 (2) 23 (6)
0 15 (4)
0 400 800 1200 1600 2000 2200
Speed – r/min 8 (2)
0
0 400 800 1200 1600
Speed – r/min
56,5 (500)
Torque – Nm (lb in)

45,2 (400) 138 bar (2000 psi)


56,5 (500) 121 bar (1750 psi)
33,9 (300) 103 bar (1500 psi)
Torque – Nm (lb in)

45,2 (400) 103 bar (1500 psi)


22,6 (200) 69 bar (1000 psi)
33,9 (300) 69 bar (1000 psi)
11,3 (100)
34 bar (500 psi) 22,6 (200)
0 34 bar (500 psi)
0 400 800 1200 1600 2000 2200 11,3 (100)
Speed – r/min
0
0 400 800 1200 1600
Speed – r/min
11,9 (16)
Power – kW (hp)

138 bar (2000 psi)


8,9 (12)
103 bar (1500 psi)
11,9 (16)
Power – kW (hp)

6,0 (8) 121 bar (1750 psi)


69 bar (1000 psi)
3,0 (4) 8,9 (12) 103 bar (1500 psi)
34 bar (500 psi)
0 6,0 (8) 69 bar (1000 psi)
0 400 800 1200 1600 2000 2200
3,0 (4) 34 bar (500 psi)
Speed – r/min
0
0 400 800 1200 1600
Speed – r/min

104 EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011