Vane Motors - 21,6 To 37,5 CM /R (1.32 To 2.29 in /R) : Characteristics Efficiency
Vane Motors - 21,6 To 37,5 CM /R (1.32 To 2.29 in /R) : Characteristics Efficiency
Vane Motors - 21,6 To 37,5 CM /R (1.32 To 2.29 in /R) : Characteristics Efficiency
Characteristics Efficiency
An economical, efficient and compact means of applying Optimum running clearances and hydraulic balance assure
variable speed, rotary hydraulic power, these motors have sustained high efficiency over the life of the motor.
variable horsepower (constant torque) characteristics. They
can be stalled under load without damage when protected by Smooth Operation
a relief valve. Inertia of rotating parts is low ... parts are symmetrical, provid-
ing dynamic balance and freedom from vibration.
Hydraulic Balance
Two internal inlet chambers are diametrically opposed as are
two outlet chambers. This construction eliminates bearing
loads resulting from pressure, a major cause of wear in de-
signs without this feature.
98 EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011
Operating Specifications
M2U 2,0 (18) 21,6 (1.32) 38,4 (340) 2800 r/min @ 138 bar (2000 psi) 7,7
2,8 (25) 25,4 (1.55) 46,3 (410) 2500 r/min @ 138 bar (2000 psi) (17)
4,0 (35) 37,5 (2.29) 67,8 (600) 2000 r/min @ 138 bar (2000 psi)
M2–210 2,8 (25) 24,7 (1.51) 46,3 (410) 2200 r/min @ 138 bar (2000 psi) 9,5
4,0 (35) 35,4 (2.16) 56,5 (500) 1800 r/min @ 121 bar (1750 psi) (21)
Model Codes
M 2 U - 1 S 35 S - 1 C 10 L
1 2 3 4 5 6 7 8 9 10 11
7 Outlet port
3 Uni-directional rotation S – 1-5/16 – 12 st. thd. 10 Design
Subject to change. Installation
dimensions remain the same for
4 Mounting 8 Shaft type designs –10 through –19.
1 – 2-bolt flange 1 – Straight keyed
3 – Threaded
11 – Splined 11 Rotation
5 Inlet port L – Left hand (counterclockwise)
S – 1-5⁄16 – 12 st. thd. Omit for right hand (clockwise)
M 2 - 2 1 0 - 35 - 1 C - 13
1 2 3 4 5 6 7 8 9
9 Design
4 Porting 7 Shaft type Subject to change. Installation dimen-
1-3⁄4 NPT both ports 1 – Straight keyed sions remain the same for designs –10
3 – Threaded through –19.
6 – Straight keyed (stub)
11 – Splined
EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011 99
Installation Dimensions
M2U series
Dimensions in millimeters (inches)
Shaft options shown on page 101.
Dimensions OUTLET PORT
Model A B 1.3125-12 UN-2B THD.
FOR SAE HYDRAULIC FITTING
M2U–1S18S-1C10 129,8 (5.11) 105,4 (4.15) USED WITH 1” O.D. TUBING
INLET PORT
1.3125-12 UN-2B THD.
FOR SAE HYDRAULIC FITTING
USED WITH 1” O.D. TUBING
12,7 (.50)
A
CLOCKWISE
B
67,6 Ø 11,1 (.438) ROTATION
52,3 52,3 2 HOLES
34 (2.66)
(2.06) (2.06)
(1.34) 4,1 (.16)
C 4,8 (.1875)
41,1
(1.62) KEY
62,0
(2.44) 53,8 21,13/21,00
(.832/.827)
(2.12)
Ø 82,55/82,50
124,0 Ø 19,05/19,02 (3.250/3.248)
(4.88) (.750/.749)
A Ø 82,55/82,50
47,8 (1.88) R.
(3.250/3.248)
ARROW ON RING INDICATES ROTATION
Ø 130,0 (5.12)
“35 ” INDICATES LB. IN. TORQUE PER 100 PSI
M2-200 series
Dimensions in millimeters (inches)
Shaft options shown on page 101. CONNECTION “K”
3/4 ” NPT
CONNECTION “L”
3/4 ” NPT
Fluid supply to connection “L ” provides
clockwise shaft rotation, viewed from
shaft end.
Fluid supply to connection “K ” provides
counterclockwise shaft rotation.
12,7 (.50)
4,1 (.16)
CLOCKWISE
106,4 149,9 67,6
#1 SHAFT ROTATION
(4.19) (5.90) (2.66)
53,1 4,788/4,7625
71,8 37,3 (.1885/.1875) Ø 106,27/106,47
(2.09) 41,1 (4.184/4.192)
C (2.81) (1.47) KEY
(1.62) Ø 95,3
(3.75)
106,4 21,13/21,00
(4.19) (.832/.827) Ø 82,55/82,50
(3.250/3.248)
B D 122,9
53,1 (4.84) Ø 19,05/19,02
50,8 (2.00)
(2.09) (.750/.749)
32,5 (1.28)
A 53,1
DRAIN CONNECTION (2.09)
3/8 “ PIPE THD .438 DIA – 2 HOLES
FOR MOUNTING 130,0
(5.12)
100 EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011
Optional Shafts
70,6 74,7
(2.78) (2.94)
Ø 26,9 (1.06) 31,8 (1.25) 50,8
(2.00)
16,8 #13 WOODRUFF KEY 37,3 FULL DEPTH
(.66) (1.47) OF SPLINE
9,7 (.38)
INVOLUTE SPLINE
Ø 26,9 6,4 (.25) 16/32 D.P.
FLAT ROOT – 11 TEETH
(1.06) 30 PRESSURE ANGLE
31,8 (1.25) HEX
26,08/25,82 Ø 19,08/19,02
(1.0267/1.0167) (.751/.749)
Ø 23,83/23,81 Ø 18,62/18,47
(.9380/.9375) .875-18 #2 THD. (.733/.727)
NOTE:
Nut torque 169,5 Nm (125 lb. ft.)
M2-200 series
Dimensions in millimeters (inches)
NOTE: No. 1 keyed shaft is shown
on page 100.
31,8
(1.25)
12,7
(.50) #9 WOODRUFF KEY
21,25/21,00
(.8368/.8268)
Ø 19,01/19,00
(.7485/.7480)
EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011 101
Typical Performance
M2U Series
Performance Constants:
Oil temp. 49° C (120° F), viscosity
32 cSt (150 SUS) @ 38° C (100° F)
52 (14) 61 (16)
45 (12)
38 (10)
45 (12)
30 (8)
38 (10)
23 (6)
30 (8)
15 (4)
23 (6)
8 (2)
15 (4)
0
0 400 800 1200 1600 2000 2400 2800
8 (2)
Speed – r/min
0
0 400 800 1200 1600 2000 2400
Torque – Nm (lb in)
11,9 (16) 138 bar (2000 psi) 0 400 800 1200 1600 2000 2400
8,9 (12) 103 bar (1500 psi) Speed – r/min
6,0 (8)
69 bar (1000 psi)
3,0 (4)
34 bar (500 psi)
0 14,9 (20)
0 400 800 1200 1600 2000 2400 2800
Power – kW (hp)
102 EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011
Typical Performance
M2U Series
Performance Constants:
Oil temp. 49° C (120° F), viscosity
32 cSt (150 SUS) @ 38° C (100° F)
68 (18)
61 (16)
Volume required – L/min (USgpm)
52 (14)
45 (12)
38 (10)
30 (8)
23 (6)
15 (4)
8 (2)
0
0 400 800 1200 1600 2000
Speed – r/min
0
0 400 800 1200 1600 2000
Speed – r/min
11,9 (16)
103 bar (1500 psi)
8,9 (12)
6,0 (8) 69 bar (1000 psi)
0
0 400 800 1200 1600 2000
Speed – r/min
EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011 103
M2-200 Series
Performance Constants:
Oil temp. 49° C (120° F), viscosity
32 cSt (150 SUS) @ 38° C (100° F)
38 (10) 52 (14)
30 (8) 45 (12)
23 (6) 38 (10)
15 (4) 30 (8)
8 (2) 23 (6)
0 15 (4)
0 400 800 1200 1600 2000 2200
Speed – r/min 8 (2)
0
0 400 800 1200 1600
Speed – r/min
56,5 (500)
Torque – Nm (lb in)
104 EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011