1 PROGRAMMING SOFTWARE
Valve's functional parameters can be easily set up with Atos E-SW / Z-SW programming software using proper connection to the digital driver/controller.
E - SW - BASIC / * - *
Supplies:
E-SW= for valve drivers - = first supply
N = next supply
Supported communication interfaces:
BASIC = NP (USB) PS (Serial) IR (Infrared)
FIELDBUS = BC (CANopen) BP (PROFIBUS DP) EH (EtherCAT) Option:
EW (POWERLINK) EI (EtherNet/IP) EP (PROFINET IRT) PQ = for drivers with alternated P/Q controls SP, SF, SL
Notes: E-SW-FIELDBUS allows EtherCAT, POWERLINK, EtherNet/IP and PROFINET IRT drivers programming only through USB or Serial
communication port. E-SW-*/PQ software supports the programming of valves without alternated P/Q control SP, SF, SL
Z - SW - FULL - *
Note: Z-SW-FULL allows EtherCAT, POWERLINK, EtherNet/IP and PROFINET IRT controllers programming only through USB communication port
GS500
Free programming software, web download:
E-SW-BASIC Software can be downloaded upon web registration at www.download.atos.com; service and DVD not included
Upon web registration user receive via email the Activation Code (software free license) and login data to access
Atos Download Area
The software remains active for 10 days from the installation date and then it stops until the user inputs the Activation Code
Note: the software BASIC, FIELDBUS and FULL are NOT interchangeable and must be ordered separately
Programming software FIELDBUS and FULL can program digital electronics through:
- USB communication port for all standard versions of drivers/controllers
- Serial RS232 communication port for all versions of AES s30 drivers and Z-ME-KZ s10 or higher controllers
DVD contents
Include software installer, user manuals and fieldbus configuration files:
EDS for BC - GSD for BP - XML for EH - XDD for EW - EDS for EI - GSDML for EP
Atos Download Area
Direct access to latest releases of programming software, manuals, USB drivers and fieldbus configuration files at www.download.atos.com
Software and USB drivers can be easily installed following the instruction contained in the “info.txt” files.
An automatic mailing message will inform all the registered users whenever a new software upgrade is available.
E-SW / Z-SW minimum PC requirements
Personal Computer Pentium® processor 1GHz or equivalent Memory 512 MB RAM + Hard Disk with 250MB free space
Operating System Windows XP SP3 Device Dvd reader
Monitor Resolution 1024 x 768 Interface Serial RS232 port (only for PS) or USB port
to PC USB port
AEB, REB, RES, TEB, LEB s10 or higher E-C-SB-USB/M12 cable
AES, TES, LES, PES, TEZ, LEZ s40 or higher E-A-SB-USB/OPT isolator
WARNING: drivers/controllers USB port is not isolated! Use of USB isolator adapter is highly recommended for PC protection: wrong earthing
connections may cause high potential difference between GNDs, generating high currents that could damage the PC connected to drivers/controllers.
to PC USB port
E-A-PS-USB/IR adapter
E-A-PS-USB/IR
E-MI-AS-IR s10
DRIVER CABLE
SIDE
E-MI-AS-IR s11
E-C-PS-DB9/DB9 cable
Z-ME-KZ-PS s10 or higher
Note: the adapter is not required if PC is already equipped with a serial RS232 communication port
GS500
5 BC CANbus - USB COMMUNICATION ADAPTER AND CROSS CABLES
The adapter have to be connected to the USB communication port of PC to activate the BC CANbus communication interface towards Atos digital
electrohydraulics. The cross cables connect the relevant connector of the USB adapter with the communication port of the digital drivers/controllers.
5.1 Connection tools
to PC USB port
AES s30 E-C-BC-DB9/M12 cable
AERS, TERS, TES, LES, PES s31 E-A-BC-USB/DB9 adapter
(1)
TEZ, LEZ s10
Ex-proof AES s30 E-C-BC-DB9/RA cable
Ex-proof AERS, TERS, TES, LES, s31
(1) for usage prescriptions of the
fieldbus terminator E-TRM-BC-DB9/DB9, see section 9.2
Note: for AES s30 drivers the CANbus adapter and cable are not required since driver programming can be performed via serial RS232
communication port , see 4.1
Note: for AES s30 drivers and Z-ME-KZ-PS/BP controllers, the PROFIBUS adapter and cable are not required since driver programming can be
performed via serial RS232 communication port, see 4.1
8 FIRMWARE UPDATE
It is possible to update the firmware of the following digital drivers and controllers, using proper USB communication port.
The firmware update is allowed starting from electronics series listed into the table or higher series:
E-RI-AEB s10 E-RI-REB s10 E-BM-AES s10 E-RI-TEB s10 E-BM-TEB s10 E-RI-TES s40 E-BM-TES s10 E-RI-TES-S s40 E-BM-TES-S s10
E-RI-PES-S s40
E-RI-AES s40 E-RI-RES s10 E-BM-RES s10 E-RI-LEB s10 E-BM-LEB s10 E-RI-LES s40 E-BM-LES s10 E-RI-LES-S s40 E-BM-LES-S s10
Z-RI-TEZ s40 Z-BM-TEZ s10
Z-BM-KZ s10
Z-RI-LEZ s40 Z-BM-LEZ s10
Note: for AES s30 drivers and Z-ME-KZ s10 or higher controllers the firmware update can be performed using serial RS232 communication port
Adapter side
1
M12 - 5 poles 2
male to CANopen to PROFIBUS DP to PC USB isolator adapter
2 1 3 network network USB port
4 to PC
5 120 ohm USB port
5
3 4
GS500
9.2 DB9 - terminators for USB adapter connection
The fieldbus terminators are required when USB adapter has to be connected directly to the digital driver/controller.
USB adapter
E-TRM-BC-DB9/DB9 CANopen terminator for E-A-BC-USB/DB9 USB adapter
Terminator to PC
Adapter side CAN_SHLD 5 5 CAN_SHLD Cable side USB port
DB9 - 9 poles CAN_GND 3 3 CAN_GND DB9 - 9 poles
female CAN_L 2 2 CAN_L male
5 4 3 2 1 121 ohm 1 2 3 4 5 bus line terminator must be used
CAN_H 7 7 CAN_H
USB adapter
CAN_V+ 9 9 CAN_V+
Terminator
to PC
9 8 7 6 6 7 8 9 USB port
E-TRM-BP-DB9/DB9 PROFIBUS DP terminator for E-A-BP-USB/DB9 USB adapter bus line terminator must be used