The TC-3000 Tri-Meter allows users to measure chlorine, turbidity, and color with a single device. It has six detectors to provide long-term stable readings over a variety of conditions without loss of performance. The meter comes with all necessary accessories in a carrying case for immediate testing and includes standards for turbidity calibration. Key specifications include measuring ranges of 0-10 ppm for chlorine, 0-4000 NTU for turbidity, and 0-500 color units.

Uploaded by

Juned Cool007
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views1 page

TC 3000

The TC-3000 Tri-Meter allows users to measure chlorine, turbidity, and color with a single device. It has six detectors to provide long-term stable readings over a variety of conditions without loss of performance. The meter comes with all necessary accessories in a carrying case for immediate testing and includes standards for turbidity calibration. Key specifications include measuring ranges of 0-10 ppm for chlorine, 0-4000 NTU for turbidity, and 0-500 color units.

Uploaded by

Juned Cool007
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1_Multi Parameter Section 23/5/06 16:31 Page 42

LaMotte TC-3000 Tri-Meter


Instruments & Kits
Multiparameter

(Chlorine, Turbidity and Colour)

The new TC-3000 meter gives you three meters


in one. Available in ISO or EPA versions the
meter will measure Chlorine, turbidity and
colour. The unique six detector design allows for
long term stability over a wide range of
operational conditions with no loss in
performance.

Each unit is supplied in a carrying case with


everything needed to undertake testing
Instruments & Kits A- Z

immediately including DPD tablets, sample


tubes, battery, sample bottle, 0, 1, and 10 NTU
Single Parameter

turbidity standards and comprehensive


instruction/procedures manual.

SPECIFICATIONS
Turbidity
Unit of measure NTU, FNU, FAU, ASBC, EBC
Range 0-4000
Resolution 0.01NTU/FNU 0.00-10.99
0.1NTU/FNU 11.00-109.9
1NTU/FNU 110 - 4000
Accuracy +/-2%
Monitors/Analysers A-Z

Range selection Automatic


Detection limit 0.05NTU/FNU
Reproducibility 0.02NTU/FNU 0.5FAU
On-line

Light source 860nm LED(ISO) Tungsten (EPA)

Chlorine
Range 0-10ppm (mg/l)
Resolution 0.01ppm(0-5) 0.1ppm(5-10)
Accuracy 0.02 or +/-2%
Detection limit 0.02ppm
Response time less than 5 seconds
Light source 525nm LED

Colour
Range 0-500cu
Accuracy +/- 0.5cu or 2%
Support Equipment A-Z

Detection limit 0.2cu


Light source 375nm UV LED
Resolution 0.1cu ( 0-99.9cu)
Laboratory &

Meter Features
Power 9V or AC Optional
Data logging 4000 points

ORDERING INFORMATION
TC-3000e Meter with accessories and instructions Reference: LE/1964-EPA £980.00
TC-3000I Meter with accessories and instructions Reference: LE/1964-ISO £980.00