Plate Load Test Report
Plate Load Test Report
For
CLIENT
NORTH CENTRAL RAILWAY
Contractor
Submitted To
NORTH CENTRAL RAILWAY
By
TABLE OF CONTENTS
TITLE SHEET NO
1.0 INTRODUCTION 1
5.0 CLOSURE 4
Field observations 5
Test arrangement 8
photographs 9
BHARAT INFRA CONSTRUCTIONS SHEET NO 1
1.0 INTRODUCTION
The report Presented hereunder, deals with the test results and
their interpretation, estimation of safe allowable bearing capacity
and recommendation, regarding the type, size and shape of
foundation which may be provided for the proposed structure.
The dead load was applied in the form of loaded hyva truck. The
loading arrangement is shown separately on figure. The test plate
was placed over a fine sand layer of maximum thickness of 5 mm,
so that the center of plate coincides with the center of reaction
girder/beam, with the help of plumb and bob and horizontally
leveled by a sprit level to avoid eccentric loading. The hydraulic
jack was was centrally placed over the test plate with the loading
column in between the jack and reaction beam so as to transfer
load to the plate. A minimum seating pressure of 70gm/cm2 was
applied and removed before starting the load test.
Based on the plate load test conducted at site following test result
has been observed-
ground level: 0.00 MM
Test level: 0.00 MM
Net Safe bearing capacity of soil: 25 t/m2
BHARAT INFRA CONSTRUCTIONS Carried out one plate load test for
Construction of ROB ( End to end including approaches) Km-855/27 to
856 in PRYJ-CNB Section in PRYJ Division of NCR
Following are the foundation recommendations.
5.0 CLOSURE
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
21.0
21 0
SE
22.0
23.0
24.0
25.0
26.0
27.0
28.0
29.0
30.0
SETTLEMENT