Convertisseur PR 5335a
Convertisseur PR 5335a
Convertisseur PR 5335a
5335A
– RTD, TC, Ohm, or mV input
– Extremely high measurement accuracy
– HART 5 protocol
– Programmable sensor error value
– For DIN form B sensor head mounting
Application
Connections
• Linearized temperature measurement with Pt100...Pt1000,
Ni100...Ni1000, or TC sensor.
• Difference or average temperature measurement of 2
resistance or TC sensors.
• Conversion of linear resistance variation to a standard analog
current signal, for instance from valves or Ohmic level
sensors.
• Amplification of a bipolar mV signal to a standard 4...20 mA
current signal.
• Connection of up to 15 transmitters to a digital 2-wire signal
with HART communication.
Technical characteristics
• Within a few seconds the user can program PR5335A to
measure temperatures within all ranges defined by the norms.
• The RTD and resistance inputs have cable compensation for
2-, 3- and 4-wire connection.
• The 5335A has been designed according to strict safety
requirements and is therefore suitable for application in SIL 2
installations.
• Continuous check of vital stored data for safety reasons.
• Sensor error detection according to the guidelines in NAMUR
NE89.
Mounting / installation
• For DIN form B sensor head or DIN rail mounting with the PR
fitting type 8421.
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions Output specifications
Specifications range....................................... -40°C to +85°C Current output
Calibration temperature................................. 20...28°C Signal range................................................... 4…20 mA
Relative humidity............................................ < 95% RH (non-cond.) Min. signal range............................................ 16 mA
Protection degree (encl./terminal).................. IP68 / IP00 Load (@ current output)................................. ≤ (Vsupply - 8) / 0.023 [Ω]
Load stability.................................................. ≤ 0.01% of span / 100 Ω
Mechanical specifications Sensor error indication................................... Programmable 3.5…23 mA
Dimensions.................................................... Ø 44 x 20.2 mm NAMUR NE 43 Upscale/Downscale.............. 23 mA / 3.5 mA
Weight approx................................................ 50 g *of span.......................................................... = of the presently selected
Wire size........................................................ 1 x 1.5 mm2 stranded wire range
Screw terminal torque.................................... 0.4 Nm
Vibration......................................................... IEC 60068-2-6 : 2007 Observed authority requirements
Vibration: 2...25 Hz........................................ ±1.6 mm
EMC............................................................... 2014/30/EU
Vibration: 25...100 Hz.................................... ±4 g
Input specifications
Common input specifications
Max. offset...................................................... 50% of selected max. value
RTD input
RTD type........................................................ Pt100, Ni100, lin. R
Cable resistance per wire
(max.)............................................................. 5 Ω (up to 50 Ω per wire is
possible with reduced
measurement accuracy)
Sensor current............................................... Nom. 0.2 mA
Effect of sensor cable resistance
(3-/4-wire)....................................................... < 0.002 Ω / Ω
Sensor error detection................................... Yes
TC input
Thermocouple type........................................ B, E, J, K, L, N, R, S, T, U,
W3, W5
Cold junction compensation
(CJC).............................................................. < ±1.0°C
Sensor error detection................................... Yes
Sensor error current: When
detecting / else............................................... Nom. 33 μA / 0 μA
Voltage input
5335A-012417