The document provides troubleshooting information for errors that could occur in AC/DC pumps, listing various error codes P00 through P70, describing possible causes such as short circuits, memory failure, dry run protection, or current sampling faults, and recommended solutions to remove the error such as rewiring, restarting power, or waiting for temperature to normalize.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
4K views18 pages

Difful Install Manual

The document provides troubleshooting information for errors that could occur in AC/DC pumps, listing various error codes P00 through P70, describing possible causes such as short circuits, memory failure, dry run protection, or current sampling faults, and recommended solutions to remove the error such as rewiring, restarting power, or waiting for temperature to normalize.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

Application in AC72V-280V/DC72V-420V AC/DC pumps

3
4
5
6

WARNING
1. Open circuit voltage must be lower than Max.voltage of
controller
2. Power off before wiring.
3. DC open circuit voltage should be lower than 400V.
4. Solar panels couldn't be used together with electricity.
Motor model is mismatched,please choose
matching pumps
Hardware Automatically
P00 Overcurrent UVW three-phase short-circuit connection, remove after 30s
please rewiring to ensure the normal
installation of UVW

P10 Memory failure Memory failure of controller Restart the power

P12 Full water protection Full water protection Remove after the float
switch in the tank drops

UVW three-phase open circuit,please rewiring Automatically


P43 Phase protection to ensure it reliable contact remove after 30s

Motor model is mismatched,please


choose matching pumps
Pump extension cord is too long,please
Out of step reduce the extension cord Automatically
P44
protection Power is too low, please remove after 30s
increase the power supply
Pump bearing is stuck, please
clean pump bearings
Motor model is mismatched,please
choose matching pumps
Pump extension cord is too long,please
P46 reduce the extension cord Automatically
Stall protection remove after 30s
Power is too low, please increase
the power supply
Pump bearing is stuck, please clean pump
bearings
Not all of air in the pump is exhausted,
cut off the power, re-power and start the Automatically
P48 Dry-run pump drainage after 30 seconds remove after 30
protection minutes or
There is no water in the water tank waiting re-power to clear
for water, it will restart
Motor model is mismatched,please choose
matching pumps Automatically
P49 Software remove after 30s
UVW three-phase short-circuit connection,
Overcurrent
please rewiring to ensure the normal
installation of UVW
Voltage return to
Low voltage The input voltage is too low, please normal, remove
P50
protection distribute power refer to the electrical the falut
characteristics immediately
Voltage return to
High voltage The input voltage is too high, please distribute normal, remove
P51
protection power refer to the electrical characteristics the falut
immediately
Automatically
High temperature The temperature of controller MCU is more clear after the
P60 protection than 90℃ temperature is
normal
Internal current sampling reference voltage fault
Current
P53 sampling fault If not clear after re-power,please change the Restart the power
control board

No sunlight,waiting for the sunlight to restart


Solar panel matching error, refer to the Automatical-
recommendation to match correctly ly remove
P70 Power shortage after 30s
Pump or pump bearing is stuck, and unable to
start, please disassemble the pump and rotate the
bearing to check