Report Lifting Gear-15.Vii.2021
Report Lifting Gear-15.Vii.2021
Report Lifting Gear-15.Vii.2021
No.41/CII/OP2/LG/VII/2021
DESCRIPTION : LIFTING GEAR
I CERTIFICATE OF INSPECTION
SERTIFIKAT HASIL INSPEKSI
II DIMENSION CHECK
PEMERIKSAAN DIMENSI
IV ATTACHMENT PHOTOGRAPH
CERTIFICATE OF INSPECTION
SERTIFIKAT HASIL INSPEKSI
DIMENSION CHECK
PEMERIKSAAN DIMENSI
NON DESTRUCTION TEST ( NDT )
UJI TAK RUSAK
ATTACHMENT PHOTOGRAPH
CERTIFICATE OF INSPECTION
NO.132/CII/OP2/LG/VII/21
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " Test Tank TT 100 BBL -14 " with result as follows :
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
Ir.Sulistyo Purwanto
Director
CERTIFICATE OF INSPECTION
NO.133/CII/OP2/LG/VII/21
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " Test Tank TT 100 BBL -14 " with result as follows :
The result of acceptable inspection Test Tank TT.100 BBL-14 are as follows :
MGW Size Frame Visual &
No Serial No. Tag No. Result
(Kg) (LxWxH) mm NDT.MT
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
Ir.Sulistyo Purwanto
Director
CERTIFICATE OF INSPECTION
NO.134/CII/OP2/LG/VII/21
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " Lab Cabin Container 20 FT " with result as follows :
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
Ir.Sulistyo Purwanto
Director
CERTIFICATE OF INSPECTION
NO.135/CII/OP2/LG/VII/21
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " Storage Container " with result as follows :
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
Ir.Sulistyo Purwanto
Director
CERTIFICATE OF INSPECTION
NO.136/CII/OP2/LG/VII/21
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " Choke Manifold Fuquan " with result as follows :
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
Ir.Sulistyo Purwanto
Director
CERTIFICATE OF INSPECTION
NO.137/CII/OP2/LG/VII/21
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " STT Flohead DPM " with result as follows :
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
Ir.Sulistyo Purwanto
Director
CERTIFICATE OF INSPECTION
NO.138/CII/OP2/LG/VII/21
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " Horizontal Seperator 1440 PSI " with result as follows :
The result of acceptable inspection Horizontal Seperator 1440 Psi & Lifting Set are as follows :
MGW Size Frame Visual &
No Serial No. Tag No. Result
(Kg) (LxWxH) mm NDT.MT
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " Surge Tank " with result as follows :
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
Ir.Sulistyo Purwanto
Director
CERTIFICATE OF INSPECTION
NO.140/CII/OP2/LG/VII/21
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " Sand Tank " with result as follows :
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
Ir.Sulistyo Purwanto
Director
CERTIFICATE OF INSPECTION
NO.141/CII/OP2/LG/VII/21
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " STT Flohead DPM " with result as follows :
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
Ir.Sulistyo Purwanto
Director
CERTIFICATE OF INSPECTION
NO.142/CII/OP2/LG/VII/21
THIS IS CERTIFICATE THAT, based on request of PT.Bama Bumi Sentosa, PT. Consult
International Indonesia has been inspected for " ESD Console " with result as follows :
Conclusion : Based on the result of inspection, inspector concludes that this equipment fit
to be operated.
Suggestion : Record of maintenance, modification or alteration of this equipment should be
attached on this document.
Periodical Inspection of the above equipment should be not exceed
12 ( Twelve ) Months.
Ir.Sulistyo Purwanto
Director
MAGNETIC PARTICLE TEST REPORT
Page No : 01/01
Report No : 132/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 15,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : TEST TANK
SERIAL NO. : 101010160014
TAG. NO : -
MANUFACTURE : -
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 01/01
Report No : 133/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 15,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : TEST TANK
SERIAL NO. : 101010160003
TAG. NO : -
MANUFACTURE : -
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
MAGNETIC PARTICLE INSP. DATA
EQUIPMENT : YOKE BRAND / SERIAL NO : MAGNAFLUX
MODEL : PERMANENT VOLT / AMP : -
SERIAL NO. : 003 CALIBRATION : 40 LBS
CURRENT AC : - DC : - BRAND PARTICLE : MAGNAFLUX
PARTICLE TYPE, WET : YES DRY : - CONTRAST : WCP 2 PARTICLE : 7HF
FIELD STRENGTH : 4 ~ 6 INCH BLOWING : - SPRAYING : Yes
PARTICLE APPLICATION FLOWING
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 01/01
Report No : 134/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 15,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : LAB CABIN 20 FT
SERIAL NO. : 101010200030
TAG. NO : -
MANUFACTURE : -
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 01/01
Report No : 135/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 15,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : STORAGE CONTAINER
SERIAL NO. : 101010200038
TAG. NO : -
MANUFACTURE : -
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
MAGNETIC PARTICLE INSP. DATA
EQUIPMENT : YOKE BRAND / SERIAL NO : MAGNAFLUX
MODEL : PERMANENT VOLT / AMP : -
SERIAL NO. : 003 CALIBRATION : 40 LBS
CURRENT AC : - DC : - BRAND PARTICLE : MAGNAFLUX
PARTICLE TYPE, WET : YES DRY : - CONTRAST : WCP 2 PARTICLE : 7HF
FIELD STRENGTH : 4 ~ 6 INCH BLOWING : - SPRAYING : Yes
PARTICLE APPLICATION FLOWING
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 01/01
Report No : 137/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 16,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : STT FLOHEAD DPM
SERIAL NO. : 10101003 0005
TAG. NO : BBS-FH-01
MANUFACTURE : -
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 01/03
Report No : 138/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 16,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : HORIZONTAL SEPARATOR 1440 PSI
SERIAL NO. : 1010100100 43
TAG. NO : BAMA 43
MANUFACTURE : -
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 02/03
Report No : 138-1/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 16,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : SHACKLE
CAP : 9.1/2 Ton `
TAG. NO : BBS-SC 01 ~ 04
MANUFACTURE : CROSBY
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
MAGNETIC PARTICLE INSP. DATA
EQUIPMENT : YOKE BRAND / SERIAL NO : MAGNAFLUX
MODEL : PERMANENT VOLT / AMP : -
SERIAL NO. : 003 CALIBRATION : 40 LBS
CURRENT AC : - DC : - BRAND PARTICLE : MAGNAFLUX
PARTICLE TYPE, WET : YES DRY : - CONTRAST : WCP 2 PARTICLE : 7HF
FIELD STRENGTH : 4 ~ 6 INCH BLOWING : - SPRAYING : Yes
PARTICLE APPLICATION FLOWING
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 03/03
Report No : 138-2/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 16,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : WIREROPE SLING 4 LEG
CAP : 19 Ton `
TAG. NO : BBS-HS-SL 01
MANUFACTURE : N/A
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
MAGNETIC PARTICLE INSP. DATA
EQUIPMENT : YOKE BRAND / SERIAL NO : MAGNAFLUX
MODEL : PERMANENT VOLT / AMP : -
SERIAL NO. : 003 CALIBRATION : 40 LBS
CURRENT AC : - DC : - BRAND PARTICLE : MAGNAFLUX
PARTICLE TYPE, WET : YES DRY : - CONTRAST : WCP 2 PARTICLE : 7HF
FIELD STRENGTH : 4 ~ 6 INCH BLOWING : - SPRAYING : Yes
PARTICLE APPLICATION FLOWING
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 01/01
Report No : 139/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 16,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : SURGE TANK
SERIAL NO. : 101010010061
TAG. NO : BAMA 58
MANUFACTURE : -
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 01/01
Report No : 140/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 16,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : SANDTRAP
SERIAL NO. : 101010130002
TAG. NO : BBS-ST 01
MANUFACTURE : -
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 01/01
Report No : 141/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 16,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : STT FLOHEAD DPM
SERIAL NO. : 101010030010
TAG. NO : BBS-FH-02
MANUFACTURE : -
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
MAGNETIC PARTICLE TEST REPORT
Page No : 01/01
Report No : 142/CII/OP2/NDT-LG/VII/2021
Procedure No. : OP-R2-TES-MCE-1
Inspection Date : July 16,2021
Loc.Inspection : Yard Jetty Tangkiang , Sulawesi Tengah
EQUIPMENT DATA
OWNER : PT.BAMA BUMI SENTOSA
EQUIPMENT : ESD CONSULE
SERIAL NO. : 1010100020017
TAG. NO : BBS-FEC 01
MANUFACTURE : -
STANDARD / CODE : ASME V ART 7 & AWS D1.1
ACCEPTANCE CRITERIA : AWS D1.1
SURFACE PREPARATION
AS WELDED : - AS ROLLED - AS-FORGED - GRINDING : -
MACHINING : Yes BLASTING - BRUSHING Yes OTHER : -
TEST RESULT
NO IDENTIFICATION POINT No. EVALUATION REMARK
MPI
AREA
RJ.Purbo Kusumo Didik Supriyadi
ASNT Level II
DIMENSION CHECK RECORD
GENERAL DATA RECORD
Description TEST TANK 01 Attachment Report No. : 132/CII/OP2/LG/VII/21
Tag No./Serial No. 101010160014 Year Built / User - / 2021
Owner / User PT.Bama Bumi Sentosa Date Of Inspection July 15, 2021
Manufacture / Brand - Place Of Inspection Yard Jetty Tangkiang, Sulawesi Tengah
Reference/ Code BS EN 12079 - 3 & 2
No. Description Sketch
1. DIMENSION OF OFFSHORE CONTAINER
a. Overall Dimension
Length x Width x Heigth (mm) L: 4140 W : 2420 H : 3000 L1
Remark
b. Center To Center (mm) 1 st 2nd Difference (%)
D1
Length ( L1 & L2 ) 4000 4000 - Good B1 B2
Breadth ( B1 & B2 ) 2400 2400 - Good D2
SRORAGE CONTAINER
ATTACHMENT PHOTOGRAPH
SURGE TANK
SANDTRAP
ATTACHMENT PHOTOGRAPH
ESD CONSOLE