Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
84 views
542 pages
Electromagnetic Compatibility Tests (SCF BALTICA)
Uploaded by
Sube Subic
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download
Save
Save Electromagnetic Compatibility Tests(SCF BALTICA) For Later
Share
0%
0% found this document useful, undefined
0%
, undefined
Print
Embed
Report
0 ratings
0% found this document useful (0 votes)
84 views
542 pages
Electromagnetic Compatibility Tests (SCF BALTICA)
Uploaded by
Sube Subic
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Carousel Previous
Carousel Next
Download
Save
Save Electromagnetic Compatibility Tests(SCF BALTICA) For Later
Share
0%
0% found this document useful, undefined
0%
, undefined
Print
Embed
Report
Download
Save Electromagnetic Compatibility Tests(SCF BALTICA) For Later
You are on page 1
/ 542
Search
Fullscreen
Roport No: SGS-E13-0158 Page 1 Electromagnetic Compatibility Test Report TON-R13-2111 Applicant : Techeross Co., Ltd. 84 Yeonginsan-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833 Manufacturer : Techeross Co., Ltd. 84 Yeonginsan-'o, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833 Product name : PDE-24A, Model name. : PDE-24A, Serial number: PDE2013-0001 Standard: DNV standard for certification No.2.4 IACS URE10 Date issue: February 04, 2014 Date of Receipt: December 12, 2013 K R Test Period : December 17, 2013 ~ December 23, 2013 REVIEWED Test Result : Complied Init: YS. SONG! SERS, Date’ ESE Veest seesblerds Test Tested by: 7 Approved we Jay Choi / EMC Engineer Paul Kang /TechnicalManager Beas ‘Tis docu sued bye Convery soe Geer Coons cf Sana sorte vm aes a wn sp comer, nonin hm ‘ons sow eon tebiy aaresten oe jtoscton ve ntnas eran fy Mager oe Sosa esate tt san crus neo cs he ‘Sonorlpaian tucson ran seretang aber tra egal ges tareacton saat Ts Goan sane oe paces eet sot ie wen Stews ete Company hry commones airatan forgo or eteen oh cantor agora hi dsurel ie unanesadoeders ay ba pea fe es {Mont of te low Ungse ater sated he reals shown nha at roy eer ely i Ue samp) ase ard nh vance) oe eae fr 80 ys ony TOF-510-001 ‘868 Korea Co.Report No SGS-E13.0158 Page 214 TABLE OF CONTENTS. 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST 4 3.1 CONDUCTED EMISSION TEST 7 3.2 RADIATED EMISSION TEST 12 3.3 ELECTROSTATIC DISCHARGE IMMUNITY TEST 24 3.4 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST 27 3.5 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 30 3.6 SURGE IMMUNITY TEST 32 3.7 CONDUCTED IMMUNITY TEST 34 3.8 CONDUCTED LOW FREQUENCY TEST 36 3.9 POWER SUPPLY VARIATION TEST 38 3.10 EXTERNAL POWER SUPPLY FAILURE TEST 41 4, EUT PHOTOGRAPHS 43 id S58 Korn Cots, 189 Snr dong Grp, Grong Kees 5.0 £21487 {48291-7209 _wornsgH Op sem Mente oS Gon Giza Sores)Report No. SGS-E13-0168 Page 3143 1. General Description of EUT 1.1 Applicant Company Name : Techeross Co., Ltd. Address + 84 Yeonginsan-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833, 1.2 Manufacture Company Name : Techeross Co., Ltd, Address + 84 Yeonginsan-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833, 1.3 Basic Description of EUT Product Name : PDE-24A Model Name: PDE-244 Serial Number: PDE2013-0001 Rated Voltage: AC 440 V, 60 Hz Test Voltage: AC 440 V, 60 Hz eso 868K Co..sh_| este SES roc Gia de Seven) 0 dbeon Gangs Georg 50 Korea 8231 28700 {46231 427230 _ ww sgaproun ktReport No SGS-£13.0158 Page 4143 2. General Information of Test 2.4 Test Facility This test was carried out by SGS Korea. Test Site Location : 23, Giheungdanji-ro 24beon-gil, Giheung-gu, Yongin-si, Gyeonggi-do, Korea TEL : 82-31-548-0712, FAX : 82-31-548-0719 2.2 Standard for Methods of Measurement Basic Standard Description Test Result & Complied 3.1 Conducted Emission Cail i A & Complied 3.2 Radiated Emission Bea 3. Electrostatic Discharge Immunity Test | Pl Complied 3.4 Radiated, radio-frequency, EX Complied electromagnetic field immunity test O Fail DNV standard for certification | 3-5 Electrical Fast Transient/Burst Immunity Complied No.24 Test O Fail & Complied IACS URE10 3.6 Surge Immunity Test Bear J Complied 3.7 Conducted Immunity Test Bre ‘Complied 3.8 Conducted low frequency Test Gran " Complied 3.9 Power Supply Variation test Fai & Complied 3.10 External Power Supply Failure test Grai ark Koren Coe on on Gaps Seog Kes 0 9825128570 4291421770. sso a Mente $6 Gp int de Siete)Report No. SGS-E12.0158 Page 5 1 43 2.3 Description of EUT modification N/A 2.4 Variations covered by this report N/A 2.5 Additional information related to Testing Test results apply only to the particular sample tested and functionality described in this test report. ‘This report may be reproduced in full. Partial reproduction may only be made with the written permission of the SGS Korea. 2.6 Test Conditions EUT Operating Mode Operation Modes Worst Case Mode Normal Operating Mode g 2.7 Immunity Method Display & operating condition check Criteria description |The EUT shall continue to operate as intended during and after the test. No degradation of A Performance or loss of function is allowed, as defined in the relevant equipment standard Jand in the technical specification published by the manufacturer. [The EUT shall continue to operate as intended after the test. No degradation oF Performance or loss of function is allowed, as defined in the relevant equipment standard B and in the technical specification published by the manufacturer. uring the test, degradation or loss of function or performance which is self-tecoverable is however allowed, but no change of actual operating state or stored data is allowed. [Temporary degradation or loss of function or performance is allowed during the test c Provided the function is seltecoverable, or can be restored at the end ofthe test by the |oPeration of the controls, as defined in the relevant equipment standard and in the technical [specification published by the manufacturer. non dong Guns, yen Koen gets glare SeSkoeaCo | 1894, resronReport No: SGS-E12.0188 Page 6 faa fest System layout on EUT and peri; —— Power cable, Interface cable AC 440 V 60 Hz EUT 2.9 Description of Test System ‘Type of Cables Used: Device from Type of Cable | Length (m) 2.10 Modifications = NA $58 KareaCo.u_| resto enter Grav riled Seine) Sevboran Ginn Grego, Kan SOW (ob 44251427270 _wnsaRODURAstm Report No: S6S-£12.0158 Page: 7 / 83 3.1 Conducted Emission Test In the range of 10 kHz to 30 MHz the conducted emission was measured in accordance with DNV standard for certification No.2.4. An artificial mains V-network in accordance with CISPR 16-1 is used to provide a defined impedance at high frequencies across the terminals of the EUT. The measuring bandwidth in the frequency range 10 kHz to 150 kHz is 200 Hz, and in the frequency range 150 kHz to 30 MHz is 9 kHz. The power input cables between the a.c. and d.c. power ports of the EUT and the artificial mains network is screened and not exceed 0.8 m in length. Measurements is made with all measuring equipment and the EUT mounted on, and bonded to, an earth plane. For further description of the configuration refer to the picture of the test set-up. 3.1.1 Test Condition Frequency Range of Test 10 kHz to 30 MHz Test Standard : DNV standard for certification No.2.4 IACS URE10 Test Date December 19, 2013, ‘Temperature/Humidity (24.71) °C / (82.04 1) % RH./ 101.7 kPa Input Voltage : AC 440V ) anh 3.1.2 Test Standard, Frequency Range Quasi-Peak : Item (ete) aB(2\) Bandwidth 0.01 ~ 0.15 120 ~69 200 Hz Conducted FQ) “Emission 0.15 ~0.5 79 9 kHz 0.5~30 73 9 kHz 3.1.3 Test Equipment List. Equipment Type Model ‘| Manufacture | SerialNo | CalDue Date | Use EMI Test Receiver EScI7 Ras 100778 | 2014.08.07 | & PULSE LIMITER ESH3-22 R&S 100850 | 2014.09.24 | By ~ TINE IMPEDANCE STABIIZALION | NNLK8130 | SCHWARZBECK | 8130146 | 20140705 | By NETWORK Shielded Room - Will Tech - - g on dog Buon Cenngia, Koen. 00 14623 28SHO 1482914272570 sgsouD ke aro c SS rls Gir fe Suneance)Report No. SGS-E13.0158 Page 8143 3.1.4 Test Result of Conducted Emission Input Voltage : AC 440 V Test Results Test data sheet is follow; : Complied Freq | uisn | ca | fuse une| timit | Level | Resut | Margin (ue) (08) (a8) (98) (Bw) (aBuv) (aBav) (8) 0.01 0.13 0.00 9.84 ut 119.7 49.53 59.5 60.20 0.10 0.13 0.00 9.84 ut 75.7 43.23 53.2 22.54 ose [a1 | 000 | 9a4 [is | 790 | ar22 | era] a180 0.25 0.12 0.00 9.84 ut 79.0 63.94 73.9 5.10 0.92 0.13 0.00 9.85 ut 73.0 46.42 56.4 16.60 613 [ ot | o10 [986 [tr | 730 | 4175) 5108) oit0 oor | 00s {000 | oa | i2| aos | ea60 | 74501 aaga o11 {006 | 000 | oss [2 | 767 | 4240 | 5230) za 0.25 0.06 0.00 9.84 2 79.0 63.00, 72.90 6.10 0.93 0.07 0.00 9.85 2 73.0 40.08 50.00 23.00, 3.89 0.14 0.10 9.85 L2 73.0 25.64 35.70 37.30, 0.01 0.07 0.00 9.84 L3 118.3 63.99 73.90 44.37 o11 [007 [000 [ese [1s | 757 | «160 | ~s160 ] 2010 0.25 0.07 0.00 9.84 L3 79.0 63.79 73.70 5.30 0.95 0.10 0.00 9.85 L3 73.0 38.85 48.80 24.20 8.75 1.48 0.10 9.86 3 73.0 17.56 29.00 44.00 see _[ oe | 010 [905 [is [790 [2526 | sa50 | o4s0 | Notes = 1. C.F = LISN Factor + Cable Loss / Result = Reading Level + C.F 2. All modes of operation were investigated an 3, Measurement uncertainty estimated at 2.7 The measurement uncertain k=2. 4, See next page for measurement graph. Teron ssvomtett_f \d the worst-case emissions are reported. 0 dB. ty is given with a confidence of about 95 % with the coverage factor, Senden Gon, Gone, Kara 5-0 £8231 85700148231 42720. muonsgsr Ar Merterol SES Groce de Siianee)resron! Report No: SGS-E13-0158, Page: 9 1 43 DNV & 60946 of LISN 25 Pre S I | ® an i ® a ‘<2 © we mw wow aw a ow aeeaaceeeeeeeetta Famer,
ONY eb oS 25 re evtin do ve 10k 200 80 sw MGM wow) om Frequency in He
“SS\eaelat__| 183 Sanmndong Gt, Gyan Kon 900 82313570 (2312720 ns enero SES GrouSocd ile de Sunsines|Report No. SGS-E13.0158, Page: 10 1 43 DNV & 60945 of ISN 25 Pre Letina | | lew @ Ter seme ao wane ee oe i Frequency ne
Sesion tana 0 1823105700 f46231427 23 wr sroupe Tesro0 embuef SES GeupSocc Gia eines)Tra SGS Roto: Sosersotss Paget ras 3.1.5 Photographs of Conducted Emission Test Configuration weet $ 1894 Seon org, Gunea, GyongaieKras S5.08 +8251 428570 1460314277510 _wowsggroup.kr enter 156 Gragsen Gilde Sunes)Report No: SGS-E19-0158, Page 2/43 3.2 Radiated Emission Test bg radiated emissions measurements were performed on the three-meter, EMI chamber and open- field test site. The EUT was placed on a reference ground plane. For frequencies from 160 kHz to 30 MHz measurements were made of the magnetic H field. The Foae nine antenna is an electrically active rod antenna. The frequency spectrum from 30 MHs to 2.000 MHz was scanned and maximum emission levels maximized at each frequency recorded. The wysiom Was rotated 360°, and the antenna was varied in the height between 1.0 m and 4.0 m in ondor {o Gotermine the maximum emission levels, This procedure was performed for both horizontal ord vertical polarization of the receiving antenna. 3.2.1 Test Condition Frequency Range of Test 180 kHz to 2000 MHz Test Standard DNV standard for certification No.2.4 IACS URE10 f Test Date December 19, 2013 ¢ ‘Temperature/Humidit 2 (22.141)°C / (31.041) % RH./101.5 kPa - mperature/Humidity ¢ )°C 1 ( ) b att 3.2.2 Test Standard an Frequency Range Quasi-Peak Bandwidth (MHz) L ABN) (kHz) 0.15~30 80 ~ 50 9 | Raiated 30 ~ 100 60~54 120 Emission 100 ~ 2 000 54 120 156 ~ 165 24 9 3.2.3 Test Equipment List Equipment Type Model Manufacture | SerialNo | Cal Due Date | Use EMI Test Receiver ESU26 Ras 1oo1e4 | 2014.09.13 | TRILOG ANTENNA Wule916s | SCHWARZBECK | 9163-300 | 20140419 | By Double-Ridged Horn ‘Antena HF906 Ras 100208 | 2014.08.13 | & Active Rod Antenna HFH2-Z6 R&S 100259 2014.07.17 w Amplifier 8447D HP. 2727A05297 | 2014.07.09 RB Amplifier SCU-18 R&S 10070 2014.06.21 | ‘Sm Semi-Anechoie Chamber : pi yech fe 7 resto enter SS aux Gid led Sunes) 163 Stor drm Goon Gong do Kos 0 (2312850 48231427270. egsoupleReport No: SGS-E19-0188, Page 3 48 3.2.4 Test Result of Radiated Emission Antenna + Vertical Distance : 3m RBW : OkHz Test Results : Complied Test data sheet is follow; [0.15 MHz ~ 30 MHz] Freq | Reading | Pol | A H Ant | CL_3M| Result | Limit | Margin (Wie) | (dBW) | (HV) | (.) | Com) | (eB) (a8) | (Bi) | (dB WWim) | (8) O7 40.5 v_[ 70 [100.00] 9.70 | 011 | 503 | 71.43 | 21.1 42 27.9 v_| 325 | 100.00] 946 | 0.18 | 375 | 61.17 | 237 229 | 226 v_[ 17 [100.00] 919 | 053 | 323 | 51.52 | 19.2 Notes 1. H: Horizontal polarization , V : Vertical polarization 2. QuasiPeak Level = Reading + Corr.(Antenna factor + Cable loss) 3. Margin value = Limit - QuasiPeak Level 4, Measurement uncertainty estimated at £4.41 dB. ‘The measurement uncertainty is given with a confidence of about 96 % with the coverage factor, k=2. z Frequency nz SSKorw8 Cols | &LS-0 Woon Sump Gyeangg-de E-IEKowen tI ABST 148231 427 7570_wmwsgsyroup kr resro0 ‘enters S6S Guia iReport No. SGS-E13-0168 Page a1 48 3.2.5 Photographs of Radiated Emission Test Configuration resrout emtero SG repos dale Sills)Report No: SGS-E13.0158 Page 15 43 3.2.6 Test Result of Radiated Emission Antenna : Horizontal / Vertical Distance : 3m RBW : OkHz Test Results, Complied Test data sheet is follow; [16 MHz ~ 165 MHz] Freq | Reading | Pol | A H Ant | CL_3M| Amp | Result | Limit | Margin (te) | (d8uN/m) | (HV) | (.) | Cm) (08) (B) (dB) | (dBuV) | (dBpW/m) | (eB) coo | 337 | v | 7 | 100 | 865 | 140 | 2550] 182 | 24.00 | 58 162.2 | 312 | v | 266 | 1.00 [ 072 | 141 | 2549 | 158 | 2400 | 82 Notes 1. H: Horizontal polarization , V : Vertical polarization 2. Quasi-Peak Level = Reading + Corr.(Antenna factor + Cable loss - Amplifier Gain) 3. Margin value = Limit - Quasi-Peak Level 4, Measurement uncertainty estimated at +4.41 ¢B. ‘The measurement uncertainty is given with a confidence of about 95 % with the coverage factor, k=2. 5. See next page for measurement graph. bane a rears aarc reReport No SGS.E13-0158 Page: 18 1 48 Lent nce “ewe what Frequency in MH [Horizontal] Leminc tort aes | Frequency in Mite | [ertical] 'SGS Koren CoA 1:4 Sanbor-dorg Gung, Gyangaio Kres 08 18:31 428 S70 £48231 4272570. worseyroupr estat ont f 56S ruplSosdt Gilde SellsReport No: SGS-E13-0158 Page 7 143 3.2.7 Photographs of Radiated Emission Test Configuration hart 13, Sarton dong, Supa, yenngi-,Korea 4) 48731428570 £98231 4772370. wn sgsyOUDKC esr enn S6 GrulSat ile d Suvetanea)Ss Report No: SGS-E13.0158 Page e/a 3.2.8 Test Result of Radiated Emission Antenna Horizontal / Vertical Distance 3m RBW 120 kHz Test Results : Complied Test data sheet is follow; [30 MHz ~ 4.000 MHz] Freq | Reading | Pol | A H Ant | CL_3M| Amp | Resuit | Limit | Margin (Miz) | (eByvim) | (HIV) |.) | (Cm) (a8) (68) | (48) | (a8) | (eB pW/m) | (08) 30.2 35.5, H 230 2.00 13.41 0.60 | 26.00 23.5 59.97 36.47 446 | 434 | v | 244 | 1.00 | 1677 | 089 | 2595| 341 | 68.03 | 23.93 03 | 349 | H | 25 | 190 | 1472 | 109 | 2500| 248 | 56.60 | 31.80 2i10 | 532 | v | 131 | 100 | 1200 | 177 [2528| 41.8 | 5400 | 1220 300.0 51.2 Vv 48 1.00 14.00 2.00 | 25.10 42.1 54.00 11.90 390.8 43.5 H 296 1.40 16.71 2.27 | 25.92 36.6 54.00 17.40 459.8 | 449 | H | 340 | 1.10 | 17.84 | 236 [26.30] 388 | 54.00 | 15.20 859.4 45.1 v 127 1.00 22.42 3.54 | 26.22 44.8 54.00 9.20 Notes 1. H: Horizontal polarization , V : Vertical polarization Reading + Corr.(Antenna factor + Cable loss - Amplifier Gain) it Quasi-Peak Level 2. Quasi-Peak Level 3, Margin value = 4, Measurement uncertainty estimated at 14.41 dB. ‘The measurement uncertainty is given with confidence of about 95 % with the coverage factor, k= 2. 5. See next page for measurement graph. vesroor Wane 18.34 Sorbon org Garg, CyongyeKoros 5 OD 0291285700 482.31 4272270. waw.sggroup kr Monte of SEs eulSoce ls aun)Report No SGS-£13.0158 Page 10/43 #3 8 tevtinetwv oom or rr es Frequency ine [Horizontal] ent soy § Frequency in He [Vertical] ‘estoReport No: SGS-£12.0158 Page 20 1 43 3.2.9 Photographs of Radiated Emission Test Configuration ork 1894, Snbor dang Gunp, Gyangsi do Krae 55-010 +8231 205700 1402914272070. wor segroup roo enter 6 Groups Gilde Seeiace)Report No: S6S-£13.0158 Page a 14s 3.2.10 Test Result of Radiated Emission Antenna : Horizontal / Vertical Distance : 3m RBW : 120 KHz Test Results : Complied Test data sheet is follow; [1.000 MHz ~ 2 000 MHz] Freq | Reading | Pol | A H Ant | CL_3M| Amp | Result | Limit | Margin (Me) | (d8uV/m) | (HV) |.) | (m) | (08) (a8) | (68) _ | (6B HV) | (aBuv/m) | (8) 1327.10 | 45.9 H_ | 223 | 1.00 | 2533 | 426 | 43.90 | 31.6 | 64.00 | 2240 1681.00| 46.5 H | 42 | 1.00 | 2640 | 472 | 44.00 | 336 | 54.00 | 20.40 1736.30 | 52.4 v_| 200 | 1.00 | 2656 | 476 | 44.00 | 307 | 54.00 | 1430 resron Notes 1. H: Horizontal polarization , V : Vertical polarization 2. Quasi-Peak Level = Reading + Corr.(Antenna factor + Cable loss - Amplifier Gain) 3. Margin value = Limit - Quasi-Peak Level 4, Measurement uncertainty estimated at +4.129 dB. ‘The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. 5. See next page for measurement graph Lar’ 1834, Santor dong Gung, Synngg do Korea 00 (231 BETO 1462914212270. ww.sosroup Manta S6S rol Sosit Gina de Sistas)Roport No. SGS-£13-0158 Poge : 22 1 43 go8 8 ‘ oem “oo ay ea # Frequonyin MH H [Horizontal] | a | a | | a | | | 5 ae | i | « al | of ‘ow a a poy co 7mte = | Pen he | AR [Vertical] : ea |) GH wae 05/1 | 1234S dong, ease arent 00 140291420700 #091427 250. wOsgHUp ke resron ects S6S rule Ciialede Sivas)Report No: SGS-E12.0158, Page 2) 43 3.2.11 Photographs of Radiated Emission Test Configuration paid 1894 Sondor-dong Gung, Syeongya Koes «5.0 1442314285700 14822142720 wwwsgsgrouphr esr amber of S55 Gs Socks Gil de Suan)Report No: $G8-£13.0158 Page 2143 sro) 3.3 Electrostatic Discharge Immunity Test 3.3.1 Test Condition ONV standard for certification No.2.4 Test Standard IACS URE10 Test Method IEC 61000-4-2 Test Date December 19, 2013 Output voltage Contact : 6 kV Air: kV Energy storage capacitor 150 pF Discharge resistor 3309 Performance criterion B ‘Temperature/Humidity/Pressure (21.7 # 1) °C (32.0 #1) % RH./ 101.7 kPa 3.3.2 Test Equipment List 10S Korea. _|_ 1834 Sanon Equipment Type Model Manufacture SerialNo | Cal Due Date | Use ESD SIMULATOR ESs-2000 NOISEKEN £SS0422543 | 2014.07.06 & veP : Zi Ee : & ‘ I? £ Lane on Gogo Cyan, Koren aa. 8231 BSTC0 {0825142720 wnsgsroup br Mant: of SES CrolSecs Gite fe Suvelane)Report No: SGS-£13.0158 Page 1 43 T 3.3.3 Test Result of Electrostatic Discharge Immunity Test Test Results : Complied The equipment meets the requirements. Test data sheet is follow; Discharge Result Test Point ype a Tested No | Observation | (performance CD=Contact | Voltage(kV) ; : criteria) AD=Air VoP cD 26KV | Each 10times | Normal | Complied (A) | Enclosure cD 26kV__|Each 10times| Normal | Complied (A) ‘Screw cD 46 kV Each 10 times| Normal | Complied (A) one aac . AD 48kV | Each 10 times] Normal | Complied (A) [Test Point] AD->/ cD-> Remarks ‘The primary functions as described below were fully functional during and after test. 1, There is no deterioration on the EUT S/S kun L_| 1894 Sanur dong, Gunpe, Grenade, Kee 86-40 48231428500 1482314210 worsgsU AT Tesro0t ent: SS Gra Ginale de Since)Report No: S6S-£13-0158 Page 21 48 3.3.4 Photographs of Electrostatic Discharge Immunity Test Configuration gant © 9) _| 18 Sonkon dong Gunn, Gyeongp, Keren 9-060 123 2B5700 £8251 427 Za7D_wonnsesgroun eso : Mantes cfSE5GowSoit ina ce Sunes)Report No. SGS-£13.0158 Page 27 | a3 3.4 Radiated, radio-frequency, electromagnetic field immunity test The transmitting antenna was located 3 m or 1.8 m from the EUT at a height of 1 m above the floor. Front, sides and back of the EUT were exposed to a uniform field of 10 Vim using both horizontal and vertical antenna polarizations. 3.4.1 Test Condition DNV standard for certification No.2.4 reso Test Standard IACS UREIO Test Method : IEC 61000-4-3 Test Date : December 19, 2013 Frequency range 2 80MHz~2GHz Test Voltage 2 10 Vim Amplitude Modulation 80 % AM at 1 kHz ‘Sweep rate : 80 MHz ~ 2 GHz: 1.5 x 10° decades/s (or 1% / 3 sec) Performance criterion DA ‘Temperature/Humidity/Pressure (22.24 1)°C/ (31.0 + 1) % RH. / 101.6 kPa 3.4.2 Test Equipment List Equipment Type Model Manufacture | SerialNo | Cal Due Date | Use LOG-PERIODIC ANT HLO46E R&S 100043 NA g SIGNAL GENERATOR | SMT 06 R&S 100256 | 2014.03.12 | POWER METER NRVD Ras 101297 | 20140109 | AMPLIFIER 250W1000A AR 327278 NA w AMPLIFIER 60S1G3 AR 327239 NA g FIELD PROBE Hl-6005 | ETS-LINDGREN | oooges6s | 2014.07.25 | wart OSs e189 Sabin dng Guo Geng Karen 501 52518570 11828127250. worse t : Mamie 55 Gleb Gini SinTesto Report No: SGS-E13.0158 Page 281 a3 T 3.4.3 Test Result of Radiated, radio-frequency, electromagnetic field immunity test Test Results: Complied The equipment meets the requirements. Test data sheet is follow; Renee anal pean eats Modulation (performane (MHz) (Vim) e criteria) 80~2 000 Front Vertical 10 | 80% AM(1 kHz) | Complied (A) 80 ~2000 Rear Vertical 10 | 80% AM(1 kHz) | Complied (A) 80 ~ 2.000 Right Vertical 10 | 80% AM(1 kHz) | Complied (A) 80 ~2000 Left Vertical 10 | 80% AM(1kHz) | Complied (A) 80 ~ 2000 Front Horizontal 10 | 80% AM(t kHz) | Complied (A) 80 ~2000 Rear Horizontal 10 | 80%AM(1kHz) | Complied (A) 80 ~2.000 Right Horizontal 10 80 % AM (1 kHz) | Complied (A) 80 ~ 2.000 Left Horizontal 10 80 % AM (1 kHz) | Complied (A) | Remarks The primary functions as described below were fully functional during and after test. 1. There is no deterioration on the EUT 2, Measurement uncertainty estimated at 1.47 4B. ‘The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. lad __| 143 Sorton eng Guapo, Gyoorgo, Kora 4 40 4823428 570N 48231 427270. wo agspOUD kt Netra S6 Groupe Gn de Sivlons)Report No: SGS-£13.0158 Page |: 29/43 3.4.4 Photographs of Radiated, radio-frequency, electromagnetic field immunity test Configuration 88% 3, enban dong, Guno,Gyserag do, Kero 3.010 +8231 4205700 160291427 7D wwr.ssgroup ke ston enter of S08 Bout Sockt Sina de Sale)Report No: SGS-E19.0159 Page 30/43 3.5 Electrical fast transient/burst immunity test estan The test shall be carried out as described in IEC 61000-4-6, at test severity level 3, using a test generator complying with 6.1.1 of IEC 61000-4-4, a coupling/decoupling network complying with 6.2 of IEC 61000-4-4 for power lines, and a capacitive coupling clamp complying with 6.3 of IEC 61000-4-4 for signal and control lines. 3.5.1 Test Condition DNV standard for certification No.2.4 Test Standard eatery Test Method 2 IEC 61000-4-4 Test Date : December 18, 2013 Single pulse time 2 51s (between 10 % and 90 % value) Single pulse width 2 50 ns (50 % value) Test Voltage 2 42kV (power lines) 1 KV (signal and control lines) Repetition : SkHz Application : 15 ms burst every 300 ms Duration : 5 min for each of positive and negative polarity pulses Performance criterion :B TemperaturelHumidity/Pressure (21.4 £1) °C/ (31.041) % RH. / 101.6 kPa 3.5.2 Test Equipment List Equipment Type Model Manufacture | SerialNo | Cal Due Date| Use FAST TRAE NOR OSE | FNS-AX2 NoiseKen | FNS0410252 | 2014.06.23 | 3.5.3 Test Result of Electrical fast transient/burst immunity test Test Results: Complied The equipment meets the requirements. Test data sheet is follow; Inject Result Line Repetition | Voltage | Coupling (min) (performance criteria) L1-L2-L3-PE 5 kHz #2kV Direct 5 min Complied (A) Remarks The primary functions as described below were fully functional during and after test. 1. There is no deterioration on the EUT eae SSlorsco il _| 804 ios dogo Gena Kone 5 (25267 12914720 wWsaxpaupe Monier fS6 Grune Gtnblede Senne)Report No: SGS.£13.0158 Page a1 a nat S004 | _MAG, Sanbon dong, Gun, Gyucnggda, Keres 95.010 982914285700 F482 4272570 wowwspsroup hr Testo enter f S88 Sar Soc iia de SunaReport No: SGS-E13-0158 Page 321 43 3.6 Surge immunity test Tests were conducted in accordance with DNV standard for certification No.2.4. Tests were performed to 0.5 kV to differential on power lines and 1 kV Line to earth, 3.6.1 Test Condition Test Standard DNV standard for certification No.2.4 IACS URE10 Test Method IEC 61000-4-5 Test Date December 18, 2013 Single pulse time : 1.2 us (between 10% and 90 % value) Single pulse width £80 4s (50 % value) Test Voltage : +0.5 kV (differential on power lines) 1 KV (Line to earth) Application Continuous Duration : 5 min for each of positive and negative polarity pulses Performance criterion :B TemperaturelHumidity/Pressure 2 (21.6 #1) °C/ (33.041) % RH/ 101.6 kPa 3.6.2 Test Equipment List Equipment Type Mode! | Manufacture | Serial No | Cal Due Date | Use SURGE SIMULATOR | VCS500N EM TEST vovost04627 | 2014.01.17 | & 3.6.3 Test Result of Surge immunity test Test Results: Complied The equipment meets the requirements. ve S/o) Co _| 1894 Sanbon dong Gung, Gyeong do Korea 00 £48231 425570 148231 4277570. wnsgsgroupke resto Manteo SES Gruso Ena Sivotncs)SGS Report No: SGS-E13.0158 estat Page 3 4 Test data sheet is follow; Line Voltage | Coupling | Phase(Degree) icon (performance Eel criteria) Lt toL2 20.5kV 18 oF 0, 90, 180, 270 Each 5 times Complied (A) Li toLs 20.5 kV 18 0, 90, 180,270 | Each times | —Complied (A) L2toL3 40.5 kV 18 uF 0, 90, 180,270 | EachStimes | —Complied (A) Li to PE 2tkv__| 10Q+9/ | 0,90, 180,270 | EachStimes | Complied (A) L2 to PE atkV__| 100+8 | 0,90, 180,270 | Eachsumes | Complea(a) L3 to PE t1kV 100+9 4 0, 90, 180, 270 Each 5 times Complied @ | Remarks ‘The primary functions as described below were fully functional during and after test. 1. There is no deterioration on the EUT 3.6.4 Photographs of Surge immunity test Configuration 1 _| 1034, Santonong, Gung, Gyaonggido Koes 0m 14823128510 168231 4272570 wavsgs.oupkt entero SES Gene nine de Salanes)Report No: SGS-£13-0168 Page 34 43 3.7 Conducted immunity test The EUT and all local support equipment were placed on @ non-conductive support 0.1 m above a reference ground plane (RGP) and on the floor as typical applications and were put into operation according to the specified operating mode. 3.7.1 Test Condition DNV standard for certification No.2.4 Test Standard ince UREIo Test Method : IEC 6100-46 Test Date : December 19, 2013 Frequency range 4150 kHz ~ 80 MHz Test Voltage 3v / ‘Amplitude Modulation 80.% AM at 1 kHz ‘Sweep rate 1.5 x 10° decades/s (or 1 %/3 sec) | Performance criterion ZA Temperature/Humidity/Pressure (21.8 £ 1)°C / (33.0 1) % RH. / 101.7 kPa coed 3.7.2 Test Equipment List - a Cal Due Equipment Type Model Manufacture | Serial No Date. | Use CONTINOUS WAVE LATOR cwss00cs1} EMTEST | vo744103074 | 2014.01.24 | ATTENUATOR ATTS75 EMTEST 0107-23 | 2014.04.18 | Bg Elektronik EM CLAMP M101 peenie 36879 2014.07.17 | BI 3.7.3 Test Result of Conducted immunity test Test Results: Complied ‘The equipment meets the requirements. Test data sheet is follow; Result Frequency | Test : Test | Dwell ‘ (ute) Point |CUPliNG | voltage | time | Modulation | Step Size (performance 015-80 | Power | GM. av 3s | 80%AM@1kHz | 1.0% | Complied (A) | Remarks ‘The primary functions as described below were fully functional during and after test. 1. There is no deterioration on the EUT 2. Measurement uncertainty estimated at +2.5 dB. ‘The measurement uncertainty is given with a confidence of about 95 % with the coverage factor, k= 2. SoSKueaCo Ls _| 1094 Sanbondong, Gunpe, Gyeonggi-do Keres ONO t66291 4285700 £58291 4272570 _wwrwspsgrouphr Dele Sra)Report No. SGS-£13.0158 Page: 38/43, 3.7.4 Photographs of Conducted immunity test Configuration ah jn 68K Co, _| 183 Soong Sas mena Kone 50 23145 820147 270_wnsgHNpIe estan Memtero1S55 Grup ine co SuntaneRoport No: SGS-E13.0158 Page |: 86 1 43 3.8 Conducted low frequency test Conducted low frequency test were conducted in accordance with IACS URE 10, DNV standard for certification No.2.4 3.8.1 Test Condition _ DNV standard for certification No.2.4 Test Standard IACS URE10 DNV standard for certification No.2.4 Test Method PHAGSUREIN Test Date : December 23, 2013 Temperature/Humidity/Pressure : (21.8 + 1) °C/(31.0 #1) % RH. / 101.7 kPa 3.8.2 Test Equipment List Equipment Type Model Manufacture | Serial No | CalDue Date | Use Arbitrary Generator HMF2525 HAMEG. 1757816 2014.07.19 ® Power Amplifier 7BSST2 BRYSTON | 002608 NIA & Voltmeter URES R&S to1os9 | 20140423 | & RF. Capacitor 6512-106R SOLAR : 2014.07.20 | & 3.8.3 Test Result of Conducted low frequency test Test Voltage : AC 440 V Test Results + Complied 5 The equipment meets the requirements. pes nr Test data sheet is follow; Test Condition Frequency Sweep range Test Voltage Result Up to 15" harmonics 10% of Un Complied (A) 15 to 100" harmonics Decreasing from 10% to 1% of Un Complied (A) 100" to 200" harmonics 1% of Un ‘Complied (A) Remarks The EUT com with the performance requirement during and after the test in accordance with the EUT operated normal performance within limits specified by the manufacturer. S08Ko10105 81 _ | 189, Sanbon- dong unpe Gyeongy-, Kore 0 £68231 285700 1482427270 vwsasgouD kr estan enter of S65 GS Gaede SuetReport No: SGS-E13.0158 Poge : 87) 43 3.8.4 Photographs of Conducted low frequency test Configuration wank Sosa | OY Salon ang Gung, Greeny Kea 0 8251 CEST (21427 20_ ose resron emir of S65 Grol Sot Gaede unolanes)SGS Report No. SCS-E13.0158 Poge ': 38 43 | 3.9 Power supply variation test Power supply variation test were conducted in certification No.2.4. 3.9.1 Test Condition Test Standard Test Method Test Date Test Value Temperature/Humidity/Pressure 3.9.2 Test Equipment List accordance with IACS URE10, DNV standard for DNV standard for certification No.2.4 IACS URE10 DNV standard for certification No.2.4 IACS URE10 December 23, 2013 test condition : Frequency #5 % / Voltage: +10 % (15 min) test condition : Frequency #10 %, 5s / Voltage: #20 % (1.5 s) (21.5 #1) °C / (32.0 # 1) % RH, / 101.7 kPa Equipment Type Mode! | Manufacture] SerialNo | Cal Due Dato | Use | PROGRAMMABLE YESr GRAMMY Siado_| YESPoweR| ypwoross | zo10a12 | o | resront nat 1:4 Sanen fon Gunpe Gyeong de Kors 5.0 482912850 1062312 20 wormsgseUp Kr Meter of SES Cousot ine ce Seine)Report No. SGS-E13.0158 Page |: 39 1 43 T 3.9.3 Test Result of Power supply variation test Test Voltage 1 AC 440V Test Results : Complied ‘The equipment meets the requirements. Test data sheet follows. Variations Level Test time Criteria | Result (performance criteria) Frequency +5 % / Voltage +10 % 45 min A Complied (A) Frequency +5 % / Voltage -10 % 16 min A Complied (A) Frequency -5 % / Voltage +10 % 15 min A ‘Complied (A) Frequency -5 % / Voltage -10 % 45 min A Complied (A) Frequency duration y =5 sec Frequency +10 % / Voltage +20 % Voltage duration A Complied (A) =1.5 sec Frequency duration a =5 sec Frequency -10 % / Voltage -20 % Voltage ae A ‘Complied (A) =1.5 sec Remarks ‘The EUT complies with the performance requirement during and after the test in accordance with the EUT operated normal performance within limits specified by the manufacturer. port S05 towed | 1894, Saban dong Gung, Gyonggide, Korea 8-00 (6828100 14623142770. wavrsgsyroUDKT visto entra! 6S Gus naa de Satna)Report No: 65-13-0158, Page: 40/43, 3.9.4 Photographs of Power supply variation test Configuration Sesto] 14 Stn ig ig ons rn 0m 1818S 2312 wespOID rsa Mero $68 rau ina a Sita)Report No. SGS-E13.0158 Page a 143 3.10 External Power Supply Failure test External Power Supply Failure test were conducted in accordance with |ACS URE10, DNV standard for certification No.2.4. 3.10.1 Test Condition Test Standard ONV standard for certification No.2.4 IACS URE10 DNV standard for certification No. 2.4 Test Method IACS URE10 Test Date November 20, 2013 Voltage 100% Interruption (30sec) Test Value @ interruptions within a §-minute period) Temperature/Humidity/Pressure —: (21.6 £1) °C/(35.0 4 1) % RH./ 101.0 kPa 3.10.2 Test Equipment List Equipment Type PROGRAMMABLE CV.CF Model | Manufacture | Serial No | Cal Due Date Use | YEsF-s1000 | Yes POWER] vewotos5 | 20140312 | 6 | estan gent ~_ 19 Soberng, Gunso, Geng, ees 5.210 291205700 +8251 42720 wawsgsrouphe ents of 65 Grupos nade Seles)Testo Report No. SGS-F13.0158 Page a2 143 3.10.3 Test Result of External Power ‘Supply Failure test Test Voltage : AC 440 Test Results : Complied The equipment meets the requirements. Test data sheet follows. Nominal voltage interruption Duration Result 3s aus (during 5 minutes) Complied “=”? Remarks The EUT complies with the performance requirement during and after the test in accordance with the EUT operated normal performance within limits specified by the manufacturer. Note) The EUT is power off during the test. After the test, the EUT is normal operating with the operator's intervention. 3.10.4 Photographs of External Power ‘Supply Failure test Configuration park Stouts | 1854 Srbodona Gg, erga oa SEO +2914 570 48231427280. wm sgsupr enter f S68 Gu Soks iia de Surlase|Report No: SGS-€13.0158 Page 8/4 [4. EUT Photographs [EUT] wert Sur, Gono Kore 85.080 1482314285700 1482.31 27 250_wsgsgrupss Manteo S65 GunSo Gide do Silane) S08 Kore. sroresto Report No. SGS-E19.0160_Rewt Page 171 44 Electromagnetic Compatibility Test Report Reference No.: TON-R13-2113 Applicant : Techoross Co., Ltd 84 Yeonginsar-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833 Manufacturer Techcross Co., Ltd. 84 Yeonginsan-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833 Product name : PDE-A4 Model name. : PDE-A4 Sorial numbs PDE2013-0003 Standard: DNV standard for certification No.2.4 IACS URE10 Date Reissue: June 05, 2015 Date of Receipt: December 12, 2013, Test Period : December 17, 2013 ~ December 23, 2013 Test Result : ‘Complied Tested by : ZOD Approved by: ae Jay Choi / EMC Engineer Paul Kang /Technical MAnager SGS Korea Co., ‘his sonar ented ay he Carpany sat ots Garr Conse of Send ped owt sabia rene er esse a wr 8 conten conn tn ‘erinis yn oe tion otal, ester ba recon kas Gated eran. foy haat ea Sones Company Sean a rw te oe Stertitn a ‘cover patents radio tr eager an Semaval dhe Cangany hoy conmotans shea age ‘fet ofthe ton Urges tore snide rela shown ints ls rope eer chy fo te semalee ened ana nth ronpos) ae ead for 9 dos Sn TOF-510-001 6S Kores Cot, 0 8231 enter S68 oufSocii rae de Suelo!Report No: SGS-£19-0160_Rev.t Page 21 44 Revisions Rev No. Details Date 0 Original issue Feb. 04, 2014 4 Delete line of 859.3 Mk on 19 Page Jun. 05, 2015 868 Kora Co.is_| 4.1510 dbo Gunga si Geng, 5 Korea 1123 esta nis SES Grol Gere de Suneares) 00 96242720 _wosgeg up hrReport No: SGS-E12-0160 Rev.1 Page 3/44 TABLE OF CONTENTS 1, GENERAL DESCRIPTION OF EUT 4 2. GENERAL INFORMATION OF TEST 5 3.1 CONDUCTED EMISSION TEST 8 3.2 RADIATED EMISSION TEST 13 3.3 ELECTROSTATIC DISCHARGE IMMUNITY TEST 25 3.4 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST 28 3.5 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 31 3.6 SURGE IMMUNITY TEST 33 3.7 CONDUCTED IMMUNITY TEST 35 3.8 CONDUCTED LOW FREQUENCY TEST 37 3.9 POWER SUPPLY VARIATION TEST 39 3.10 EXTERNAL POWER SUPPLY FAILURE TEST 42 4, EUT PHOTOGRAPHS 44 88 Kora 41S ro tereor gl Sunpos Gyeongg a 5-H Koren 116291 65700 £16291.4272570_wwwsgsqoupr entre 56 GS Céad Sunes) stonSGS Roport No: SGS-E13.0160 Rev. Page: 4 1 44 1. General Description of EUT 1.1 Applicant Company Name : Techcross Co., Ltd. Address : 84 Yeonginsan-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833, 1.2 Manufacture Company Name : Techeross Co., Ltd, Address + 84 Yeonginsan-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833 1.3 Basic Description of EUT esto Product Name: PDE-A4 Model Name —: PDE-A4 Serial Number; PDE2013-0003 Rated Voltage: AC 440 V, 60 He Test Voltage: AC 440 V, 60 He 88 Koren Co.Roport No.: SGS-E13.0160_Rev.1 Page: 8 / 44 2. General Information of Test 2.1 Test Facility This test was carried out by SGS Korea. Test Site Location : 23, Giheungdanji-ro 24beon-gil, Giheung-gu, Yongin-si, Gyeonggi-do, Korea TEL : 62-31-548-0712, FAX : 82-31-548-0719 2.2 Standard for Methods of Measurement Basic Standard Description Test Result Complied 3.1 Conducted Emission Fira : ‘Complied 3.2 Radiated Emission Alrall : & complied 3.3 Electrostatic Discharge Immunity Test | F Fi 3.4 Radiated, radio-frequency, Complied electromagnetic field immunity test O Fail DNV standard for certification _ | 9-5 Electrical Fast Transient/Burst Immunity | JX] Complied No.2.4 Test O Fail IACS URE10 3.6 Surge Immunity Test 8 ree 3.7 Conducted Immunity Test Complied 3.8 Conducted low frequency Test 8 Compled 3.9 Power Supply Variation test a Compiled i Xl Complied 3.10 External Power Supply Failure test Aes $88 KereaGoiud_| 4 a i, Gangs eon srReport No.: SGS-E13.0160 Rov: Page 61 a4 2.3 Description of EUT modification NA 2.4 Variations covered by this report NIA 2.5 Additional information related to Testing Test results apply only to the particular sample tested and functionality described in this test report. This report may be reproduced in ful. Partial reproduction may only be made with the written permission of the SGS Korea 2.6 Test Conditions EUT Operating Mode Operation Modes Worst Case Mode Normal Operating Mode & 2.7 Immunity Method Display & operating condition check. Criteria description [The EUT shall continue to operate as intended during and after the tast. No degradation of A performance or loss of function is allowed, as defined in the relevant equipment standard land in the technical specification published by the manufacturer. [The EUT shall continue to operate as intended after the test. No degradation of lperformance or loss of function is allowed, as defined in the relevant equipment standard B land in the technical specification published by the manufacturer. [During the test, degradation or loss of function or performance which is setf-recoverable is however allowed, but no change of actual operating state or stored data is allowed. [Temporary degradation or loss of function or performance is allowed during the test, e lprovided the function is self-tecoverable, or can be restored at the end of the test by the operation ofthe controls, as defined inthe relevant equipment standard and inthe technical S6SKorwsCo,.i_| 418: Wtheani Guns; Gyenayo,25.0Kara 1652314285700 f+8291.427200_wwvwsospoup ke Memiere SES Goi vba de Sets) vesro0SGS Test System layout on EUT and Power cable, erals Interface cable Report No. SGS-E13.0160_Rov.1 Page T7144 AC 440 V 60 liz EUT 2.9 Description of Test System Type of Cables Used: Device from | 2.10 Modifications NIA esr Device to Type of Cable Length (m) Type of shield |Roport No SGS-E13.0160_Rev.1 Page Bi 44 3.1 Conducted Emission Test In the range of 10 kHz to 30 MHz the conducted emission was measured in accordance with DNV standard for certification No.2.4. An artificial mains V-network in accordance with CISPR 16-1 is used to provide a defined impedance at high frequencies across the terminals of the EUT. The measuring bandwidth in the frequency range 10 kHz to 150 kHz is 200 Hz, and in the frequency range 150 kHz to 30 MHz is 9 kHz. The power input cables between the a.c. and d.c. power ports of the EUT and the artificial mains network is screened and not exceed 0.8 m in length. Measurements is made with all measuring equipment and the EUT mounted on, and bonded to, an earth plane. For further description of the configuration refer to the picture of the test set-up. 3.1.1 Test Condition Frequency Range of Test 10 kHz to 30 MHz Test Standard : DNV standard for certification No.2.4 IACS URE10 Test Date : December 19, 2013 Temperature/Humidity (21.7£1)°C J (32.0 + 1)% RH./ 101.7 kPa Input Voltage : ACA40V 3.1.2 Test Standard. Frequency Range Quasi-Peak bail (MHz) dB(i) 0.01 ~ 0.15 120 ~ 69 Conducted ®] “Emission O15~05 79 0.5~30 73 3.1.3 Test Equipment List. Equipment Type Model Manufacture SerialNo | Cal Due Date | Use EMI Test Receiver Esci7 Ras 100778 | 2014.08.07 | & PULSE LIMITER ESH3-Z2 R&S 100850 2014.09.24 & LINE IMPEDANCE 7 STABILIZATION, NNLK8130 | SCHWARZBECK | 8130146 | 2014.07.05 | & NETWORK Shielded Room - Will Tech - 7 g 868 Korea Co. a hea gl Gunpesi Gyenrg 500 Kaeo esronRoport No. SGS-E13.0160_Rev-1 Pat ol M4 3.1.4 Test Result of Conducted Emission Input Voltage : AC 440 V Test Results: Complied Test data sheet is follow; Freq. | Lisn | PURE | ca tine} tim | Level | Resut | Margin (te) (a8) | (8) | (@) (a8) (a8) (a8) (08) 0.01 0.13 9.84 0.00 u 119.7 62.43 72.4 47.30 cos | o13 | 9a | ooo | is | oa | 2103 | 313 65.00 oat] 012 | a5 | ooo || 790 | sos | 405 38.60 2.00 0.14 9.85 0.10 ut 73.0 29.81 39.9 33.10 aso | oz | 9a | o10 |i | 730 | 1992 | aoa 42.90 oot | 00s | oes | ooo [iz] t193 | 6260 | 7250 | 4676 004 | 00s | 084 | 000 | 12 | 64 | 2180 | 170 | 6169 0.41 0.06 9.85 0.00 L2 79.0 30.39 40.30, 38.70 21s | 009 | 9as | o10 | 2 | 730 34.26 44330 28.70 to7e | o21 | 986 | o10 | 2 | 730 1733 | 27.50 45.50 0.01 0.07 9.84 0.00 3 119.3 59.69 69.60 49.66 oo | oo7 | 964 | 000 | 13 | 064 | 2160 | 31.00 | 0460 oat | 007 | 985 | 000 | 13 | 700 | 2078 | 3870 | 4020 215 015 9.85 0.10 L3 73.0 29.40 39.50 33.50 6.99 0.85 9.86 0.10 L3, 73.0 23.49 34.30 38.70 ISN Factor + Pulse Limiter + Cable Loss / Result = Reading Level + C.F 2. All modes of operation were investigated and the worst-case emissions are reported. 3, Measurement uncertainty estimated at 42.70 dB The measurement uncertainty is given with a confidence of about 95 % with the coverage factor, k=2 4, See next page for measurement graph. 86S Kora Co, estaReport No: SGS-£13-0160 Revt Page: 10 / 44 NV 60945 of ISN 25 Pre Letina ‘m2 0 stk 0 300 DM OM SM OM I Frequency in Hz
DNV & 60945 of LISN 25 Pre Latin dy ‘x #0 © 10k m0. SMM OM tO) OM Frequency inte
SOSKores Cod | 1S. ltbeengi Gung si Gyongy ea 06. H0Kere t48231 4285700 £48291 477 270_wwwsasroup Ar | seston Manter ASS Grows ano)Report No: SCS-E13.0160_Rev.1 Page mf 44 reston meting OD ‘86S Kores Col DNV & 60945 of LISN 25 Pre eo 0 300 SoM Frequency in He
a sin | |Report No: SGS.£19-0160_Rev.t Page 12! 4 3.1.5 Photographs of Conducted Emission Test Configuration th {6 418, ttoon gl Sung Syeoggde, 0 Kora 148231 (28570 £18251 4272570 wo sesqoupe aes ania S6 rouplSooe Gale de Sales)Report No: SGS-E13-0160_Rev:1 Page 131 44 3.2 Radiated Emis: n Test The radiated emissions measurements were performed on the three-meter, EMI chamber and open- field test site. The EUT was placed on a reference ground plane. For frequencies from 150 kHz to 30 MHz measurements were made of the magnetic H field. The measuring antenna is an electrically active rod antenna. The frequency spectrum from 30 MHz to 2.000 MHz was scanned and maximum emission levels maximized at each frequency recorded. The system was rotated 360°, and the antenna was varied in the height between 1.0 m and 4.0 m in order to determine the maximum emission levels. This procedure was performed for both horizontal and vertical polarization of the receiving antenna 3.2.1 Test Condition Frequency Range of Test Test Standard Test Date ‘Temperature/Humidity 3.2.2 Test Standard 180 kHz to 2.000 MHz DNV standard for certification No.2.4 IACS URE10 December 17, 2013 (22.1 1)8C / (31.04 1) % RH. / 101.5 kPa i Frequency Range Quasi-Peak Bandwidth e (MHz) dB) (kHz) 0.15 ~30 80 ~ 50 9 fa) Radiated 30 ~ 100 60 ~ 54 1 Of} Emission 100 ~ 2.000 54 120 [7 KhR \\ 156 ~ 165 24 2 Of SI Saf 3.2.3 Test Equipment List yet Equipment Type Model Manufacture SerialNo | Cal Due Date | Use EMI Test Receiver ESU26 R&S fooies | 20140913 | Bt TRILOG ANTENNA vutpo16s | SCHWARZBECK | 9163-390 | 2014.04.19 | & Pale need HF906 R&S 100608 | 2014.08.13 | BY intenna a Active Rod Antenna HFH2-26 Ras. 100269 | 20140717 | & Amplifier SCU-18 Ras. 10070 2014.06.21 | Bl | Amplifier 8447D HP 2727a0s297 | 2014.07.09 | 3m Semi-Anechoic cheriber - Will Tech 7 = 8 seston SE8Kores Dos _| 4.181018 .Gunge yoangg-ea 8 0NDKees 6291285700 64291427 2070_wowsgseroup kr ‘Meme f SES Ge Son ne de Sul]Report No: SGS-£13.0160_Rev.1 Pape 14 1 44 3.2.4 Test Result of Radiated Emission Antenna : Vertical Distance : 3m RBW : OkHz Test Results, Complied Test data sheet is follow; [0.15 MHz ~ 30 MHz) Freq | Reading | Pol | A H Ant | CL_3M]| Result | Limit | Margin (Wey | (aBywirmy |(HIV) | (| Com) | (48) | (6B)_| (au) | (aByW/m) | _ (4B) 44 206 | V | 0 [10000] 947 | 018 | 3902 | 61.33 | 221 j93 | 122 | Vv | 123 |10000[ 941 | 049 | 221 | 5249 | 304 223 | 2065 | v | 160 |10000/ 924 | 052 | 303 | 5167 | 21.4 295 | 383 | V | 303 10000] 374 | 059 | 476 | 50.10 | 25 Notes 1. H:: Horizontal polarization , V : Vertical polarization 2. QuasiPeak Level = Reading + Corr.(Antenna factor + Cable loss) 3. Margin value = Limit — QuasiPeak Level 4, Measurement uncertainty estimated at £4.41 dB. The measurement uncertainty is given with a confidence of about 95 % with the coverage factor, k=2 Frequency in He ogg, 5 ODKorea 14823128570, sn S6SKow Cost | 41Sroleeensi Gung 71_wuwsgsgroup. sr Gina de Sunelires)Report No: SGS-E13-0160_Rev.1 Page: 18 / ad 3.2.5 Photographs of Radiated Emission Test Configuration 0SKerae Catt _| 415-0 Waeongi Gung si Gyeonggidn 5-00 Kore 146231 AZ8S7NO 148231421 2570_vMNWSISgOUD HF TesToOt ‘Mento 56 Gipson Ga Sunes)Report No: SGS-£13-0160 Rov.t Page: 16 / 44 t 3.2.6 Test Result of Radiated Emission Antenna : Horizontal / Vertical Distance : 3m RBW : kHz Test Results : Complied Test data sheet is follow; [156 MHz ~ 165 MHz] Freq | Reading | Pol | A H Ant |CL_3M| Amp | Result | Limit | Margin (Mz) | (dByvim) | (HIV)| (.) | Com) | (08) (08) (48) | (cBuv) | (cBuVIm) | (dB) 162.2 | 187 H_| 245 [100.00/ 10.00 | 1.41 | 2549 | 46 | 2400 | 194 156.3 | 17.3 v_| 197 [100.00] 9.85 | 1.40 | 26.52 | 30 | 2400 | 21 vesro0t Notes 1. H: Horizontal polarization , V : Vertical polarization 2. Quasi-Peak Level + Corr.(Antenna factor + Cable loss - Amplifier Gain) 3. Margin value = Limit — Quasi-Peak Level 4, Measurement uncertainty estimated at +4.41 dB... The measurement uncertainty is given with a confidence of about 95 % with the coverage factor, k=2. 5. See next page for measurement graph. vw sgspcup ie ol SS Grupo Giro de Sunline) 6 Kera Co..Report No SGS-E13-0169_Rev1 Page 7 1 44 se eye e Frequency MHz [Horizontal] g eotineawv Ltd, Frequency in Mee [Vertical] {1S boon 9h Gunes, Gyangy do, Kova 116231 85700 {462914277500 _www.sgsqroun kr Meniro SE rp Gal fe Surslnes) Sores Cot vesrtReport No. SGS-£13-0160_Rev.1 Page: 18 / 44 3.2.7 Photographs of Radiated Emission Test Configuration SSkeree Cott | 41S roleeongi Gung Gyeongae cn 5.0 Kora 148231 4265700 f66231 40720. wwwsosproup kr | ‘Menta of SES GenutSoeit Gindrale de Sinlircs)Report No, Page SGS-E13.0160_Rev-t resto ne I Ee 3.2.8 Test Result of Radiated Emission Antenna : Horizontal / Vertical Distance 3m RBW 2 120 kHz Test Results : Complied Test data sheet is follow; [30 MHz ~ 1 000 MHz] Freq | Reading | Pol A H Ant | CL_3M| Amp | Result | Limit | Margin (tr) | (Byvim) | (HV) | (.) | Com) | (8) (6B) | (dB) | (aBpV) | (aBpW/m) |] (cB) 00 | 415 | V | 67 | 11000 1507 | 109 |2590| 318 | 5663 | 2483 103.2 | 380 | V | 268 | 10000| 1267 | 1.32 [2578| 262 | 54.00 | 27.80 240.4 | 442 | H | 26 | 150.00| 13.91 | 1.94 | 2522[ 318 | 54.00 | 22.20 405.9 | 348 | H | 39 | 120.00] 47.23 | 234 |2603| 283 | 5400 | 25.70 720.9 | 385 | v | 165 | 100.00] 2188 | 316 | 2647| 37.1 | 54.00 | 16.90 859.3 | 382 H_| 203 | 100.00] 23.21 | 354 |2622| 387 | 5400 | 15.30 973.1 32.5 H 323 | 100.00 | 24.28 3.77_ | 25.95 34.6 54.00 19.40 Notes 1. H: Horizontal polarization , V : Vertical polarization 2. Quasi-Peak Level = Reading + Corr.(Antenna factor + Cable loss - Amplifier Gain) 3. Margin value = Limit - Quasi-Peak Level 4. Measurement uncertainty estimated at +4.41 dB. ‘The measurement uncertainty is given with confidence of about 95 % with the coverage factor, k= 2. 5. See next page for measurement graph. ‘S6SKorasCoth_| 4LS,o laeongi Guno-s Gyorgy to, 48-H0Koren 1821428570 Mento SES ea 2 a2) oe gp oun SwaleReport No: SGS-£13-0180 Rev Page 2) 44 = oo am mo a Frequency ine Pr [Horizontal] tinge 5 Frequency a [Vertical] seSkoeeColt_| ALS meg ups Segp a SOmKawe 1651 eas ELA sD —_—_| ert SS Gp Sit Cn de Sian resonReport No: SGS-E13.0160_Rev.1 Pogo: Dt! 44 3.2.9 Photographs of Radiated Emission Test Configuration $68 or Co..it_| 4LS+0 Wadeonl Gunp- Gyorgy do05.0 Kora 148231 29570 {+8231 07 Z70_worwsgspoupr ‘Member ct SS GroupScciét Générale de Sunes) vesroatReport No: SGS-€13-0160_Rev.1 Pape 2! 44 3.2.10 Test Result of Radiated Emission Antenna : Horizontal / Vertical Distance : 3m RBW = 120 kHz Test Results Complied Test data sheet is follow; [1.000 MHz ~ 2 000 MHz] Freq | Reading | Pol | A | H Ant |CL_3M| Amp | Result | Limit | Margin (itz) | (Bim) | (HV) | (-) | Com) | (68) (08) (38) | (Buv) | (BuWm) | (8) than the limit by over 20dB 3# The emission lo Notes 1. H : Horizontal polarization , V : Vertical polarization 2. Quasi-Peak Level = Reading + Corr.(Antenna factor + Cable loss - Amplifier Gain) 3. Margin value = Limit - Quasi-Peak Level 4, Measurement uncertainty estimated at +4.129 dB. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k= 2. 5. See next page for measurement graph. srReport No: SGS-£13-0160_Rev.1 Page 23) 44 meine 5 Frequency ln MH [Horizontal] einen 8 Frequency in Miz [Vertical] ‘S6SKorwaCo.int__| LS, Wzeongl Gung Gyengy co, 35.0Karee t482:3 428570 {48231 425 Z70_vwsasgroUp hr ‘Nant of SES Geo Gnade Suntionce), resro0tReport No: SGS-E13.0160 Rev. Page ae 3.2.11 Photographs of Radiated Emission Test Configuration SS Kare Co. 418-0 Wear 95 restReport No SGS-E13.0160_Rev.t Page 25) 44 3.3 Electrostatic Discharge Immunity Test ‘The EUT shall be placed on, but insulated from, a metal ground plane (HCP: Horizontal Coupling Plane) which projects at least 0.5 m beyond the EUT on all sides and were put into operation according to the specified ‘operating mode. Discharges from the generator shall be applied to those points and surfaces that are accessible to personne! during normal usage. 3.3.1 Test Condition DNV standard for certification No.2.4 Test Standard > ACS URETO Test Method IEC 61000-4-2 Test Date : December 19, 2013 Output voltage : Contact : 6 kV Air :8kV Energy storage capacitor : 150 pF Discharge resistor 3300 Performance criterion :B ‘Temperature/Humidity/Pressure 2 (21.7 £1) °C/ (32.0 + 2) % RH. / 101.7 kPa 3.3.2 Test Equipment List Equipment Type Model Manufacture | SerialNo | CalDue Date | Use Electrostatic Discharger ESS-2000 NOISEKEN ESS0422543 2014.07.06 gw veP < - : : Q 1 2N0_ www ssgroup ape Gini do Sue SoSkoresCo.tt_| 4S When Gump Synge, 35.40Kaea eroReport No: SGS-£13.0160 Rov. Page: 28) 44 3.3.3 Test Result of Electrostatic Discharge Immunity Test Test Results: Complied The equipment meets the requirements. Test data sheet is follow; ; Ce Test eeu Test Point | op, act | Vo Tested No. | Obeeraton | (performance ir vcP cD t6 kV Each 10 times Normal Complied (A) Enclosure, [ cD 26kV | Each 10 times] Normal Complied (A) Display, Button ‘AD 48 kV Each 10times| Normal | Complied (A) [Test Point] AD->/ CD-> Remarks The primary functions as described below were fully functional during and after test. 1. There is no deterioration on the EUT 868 Kaeo. S10 Wear gl Gupos Geongpd, 5 08 Kren 823 285700 +6231 427 2570_ww.sgeroup he resro0 enor SE rst Gn Sunes)Report No: SGS-£13.0160_Rev1 Page: BY | 44 3.3.4 Photographs of Electrostatic Discharge Immunity Test Configuration 68 Koos Co, 10 Edvoo gi Gunp-s Gyongg co, 25.10Karea resto vient SES Grup Sot Giri ge Sane BTN {4429121 7279_ wsgsgrupReport No: SGS-£13-0160_ Rev.t Page 28 4 3.4 Radiated, radio-frequency, electromagnetic field immunity test The transmitting antenna was located 3 m or 1.8 m from the EUT ata height of 1 m above the floor. Front, sides and back of the EUT were exposed to a uniform field of 10 Vim using both horizontal and vertical antenna polarizations. 3.4.1 Test Condition DNV standard for certification No.2.4 Test Standard ° TACS URE10 Test Method IEC 61000-4-3 Test Date December 20, 2013 Frequency range 80 MHz ~ 2 GHz Test Voltage 10 Vim Amplitude Modulation 80 % AM at 4 kHz ‘Sweep rate 2 80 MHz ~ 2 GHz : 1.5 x 10° decadesis (or 1% / 3 sec) Performance criterion DA Temperature/Humidity/Pressure (22.2 +1) °C/ (31.0 + 1) % RH. / 101.6 kPa 3.4.2 Test Equipment List Equipment Type Model Manufacture SerialNo | Cal Due Date | Use LOG-PERIODIC ANT HLO46E, R&S 100043 NA w Signal GENERATOR SMTO06 Ras 100256, 2014.03.12 | B POWER METER NRVD R&S 101297 2014.01.09 | & | AMPLIFIER 250W 10008 AR 0327278 NA & AMPLIFIER 60S1G3 AR 0327239 N/A ® S8Kores Cos _| 418 tbeongi Cuno Gyorgy ta 35.0 Karea t+2231 (28570 £48231 477 2570_vawwsgsroupAr a ‘Mente S55GoupSood rede Sunelies!Eston Report No SGS-E13-0160_Rev.1 Page 20) 44 3.4.3 Test Result of Radiated, radio-frequency, electromagnetic field immunity test Test Results : Complied The equipment mi ts the requirements. Test data sheet is follow; Frequency Field Result Range lange Penne Strength | Modulation _ | (performanc (MHz) a! (vim) e crite 80 ~ 2000 Front Vertical 10 80% AM (1 kHz) | Complied (A) 80 ~ 2.000 Rear Vertical 10 | 80% AM(t kHz) | Complied (A) 80 ~ 2.000 Right Vertical 10 | 80% AM(1 kHz) | Complied (A) 80 ~ 2.000 Left Vertical 10 | 80% AM(1kHz) | Complied (A) 80 ~ 2 000 Front Horizontal 10 | 80% AM(1 kHz) | Complied (A) 80 ~ 2.000 Rear Horizontal 10 | 80%AM(1kHz) | Complied (A) 80 ~ 2000 Right Horizontal 10 80 % AM (1 kHz) | Complied (A) 80 ~ 2000 Left Horizontal 10 80 % AM (1 kHz) | Complied (A) Remarks ‘The primary functions as described below were fully functional during and after test. 4. There is no deterioration on the EUT 2. Measurement uncertainty estimated at +1.47 dB. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k= 2. S68 Kores Cont _| 41S Wedeongi Guns Gyorgy to 55.0 Koren {1231478 $70 144231427 257_wowwsasroupr ‘Mamie 2565 Gs Soit irre de Seles)Report No. SGS-E13-0160_Rev.1 Page 30 / 44 3.4.4 Photographs of Radiated, radio-frequency, electromagnetic field immunity test Configuration ‘868orea Co. 585.050) esrontRoport No. SGS-E13.0160_Rev.1 Page of 44 3.5 Electrical fast transient/burst immunity test The test shall be carried out as described in IEC 61000-4-4, at test severity level 3, using a test generator complying with 6.1.1 of IEC 61000-4-4, a coupling/decoupling network complying with 6.2 of IEC 61000-4-4 for powerlines, and a capacitive coupling clamp complying with 6.3 of IEC 61000-4-4 for signal and contro! lines. 3.5.1 Test Condition DNV standard for certification No.2.4 Test Standard ics UREIO Test Method IEC 61000-4-4 Test Date December 18, 2013, Single pulse time 5 ns (between 10 % and 90 % value) Single pulse width 50 ns (50 % value) Test Voltage +2 kV (power lines) 41 KV (signal and control lines) Repetition kHz Application 15 ms burst every 300 ms Duration 5 min for each of positive and negative polarity pulses Performance criterion B ‘Temperature/Humidity/Pressure (21.4 £1) °C / (32.0 # 1) % RH./ 101.6 kPa 3.5.2 Test Equipment List Equipment Type Mode! | Manufacture | SerialNo | Cal Due Date | Use FAST TRASIENT NOISE SIMULATOR FNS-AX2 NoiseKen FNS0410252 | 2014.06.23 ® Test Results: Complied Test data sheet is follow; 3.5.3 Test Result of Electrical fast transient/burst immunity test The equipment meets the requirements. inject |, Result Line Repetition Voltage Coupling ( min) | (performance criteria) L1-L2-13-PE 5 kHz 42kV Direct Simin | _Complied (A) Remarks The primary functions as described below were fully functional during and after test. 1, There is no deterioration on the EUT S68 Korea Co. esto!Report No.: SGS-E13.0160_Rev.1 Page: 92 / 44 3.5.4 Photographs of Electrical fast transient/burst immunity test Configuration S0SKoren Cost | 6 ro meen gi Guo restoReport No.: SGS-E13.0160 Rev.1 Page 33 48 3.6 Surge immunity test Tests were conducted in accordance with DNV standard for certification No.2.4. Tests were performed to 0.5 kV to differential on power lines and 1 kV Line to earth. 3.6.1 Test Condition Test Standard Test Method Test Date Single pulse time Single pulse width Test Voltage Application Duration Performance criterion Temperature/Humidity/Pressure 3.6.2 Test Equipment List DNV standard for certification No.2.4 IACS URE10 IEC 61000-4-5 December 18, 2013 1.2 us (between 10 % and 90 % value) 50 us (50 % value) 40.5 kV (differential on power lines) #1 kV (Line to earth) Continuous 5 min for each of positive and negative polarity pulses B (24.6 #1) °C (32.0 #1) % RH 101.6 kPa usta Equipment Type Model Manufacture | Serial No | Cal Due Date | Use SURGE SIMULATOR VCS500N EMTEST | vo904104627 | 2014.01 7 | a 68 Koes Cos oe2an aesro0Report No: SGS-£19-0160 Rev.t Page Be at 3.6.3 Test Result of Surge immunity test Test Results: Complied The equipment meets the requirements. Test data sheet is follow; : ; Inject ea Line Voltage | Coupling | Phase(Degree) | (Wert, (performance criteria) LitoL2 40.5 kV, 18 0, 90, 180, 270 Each 5 times. Complied (A) L1toL3 +0.5kV 18 0, 90, 180, 270 Each 5 times Complied (A) L2tols | 20.5kV 184 | 0,90, 180,270 | EachStimes | Complied (A) L1 to PE t1kV 100 +9 uF 0, 90, 180, 270 Each 5 times Complied (A) L2 to PE t1kV 100 +9 uF 0, 90, 180, 270 Each 5 times ‘Complied (A) | U3 to PE zikv | 100+9/ | 0,90, 180,270 | EachStimes | Complied (A) Remarks The primary functions as described below were fully functional during and after test. 1, There is no deterioration on the EUT 3.6.4 Photographs of Surge immunity test Configuration 88 Keren oad | 4.0 boon gi Gunpo Goerggco <35OKorea ti «Hun #423142 7570_wwwsysgroup kr Maer 56 rls vsront 2)Roport No. SGS-E13-0160_Rov-1 Page 35/44 3.7 Conducted immunity test The EUT and all local support equipment were placed on a non-conductive support 0.1 m above a reference {ground plane (RGP) and on the floor as typical applications and were put into operation according to the specified operating mode. 3.7.1 Test Condition DNV standard for certification No.2.4 Test Standard JACS URE10 Test Method : IEC 61000-4-6 Test Date December 19, 2013 Frequency range 450 kHz ~ 80 MHz Test Voltage : 3V Amplitude Modulation 80 % AM at 1 KHz ‘Sweep rate : 1.5% 10° decadesis (or 1 %/3 sec) Performance criterion 2A Temperature/Humidity/Pressure (21.8 £1) °C / (83.0 + 1) % RH. / 101.7 kPa 3.7.2 Test Equipment List Equipment Type Mode Manufacture | Serial No ie Use Continuous Wave Simulator | CWS 500CS1 | EMTEST | vo744103074 | 2014.01.24 | Bq ATTENUATOR ATTOI75 EM TEST 0107-23 | 2014.04.18 Elektronik EM CLAMP EM101 Feinmechanik 35879 2014.07.17 g\2 S88 Koos Co. 5000Kona TesTOnReport No: SGS-E13-0160_Rev:1 Page: 36) a 3.7.3 Test Result of Conducted immunity test Test Results: Complied The equipment meets the requirements. Test data sheet is follow; Frequency | Test | Coupti Test | Dwell | Modulation | Step Size | ( conn (MHz) Point ‘ouptnG | voltage | time P api ria) 015-80 | POWER | cbt | 3V 3s | 80%AM@1kHz | 1.0% | Complied (A) Remarks The primary functions as described below were fully functional during and after test. 1. There is no deterioration on the EUT 2. Measurement uncertainty estimated at +2.5 dB. The measurement uncertainty is given with a confidence of about 95 % with the coverage factor, k = 2 3.7.4 Photographs of Conducted immunity test Configuration SESKowa Colts | ALS, econ Gung resrootSGS Report No: SGS-E19-0160 Rev Page ar 44 3.8 Conducted low frequency test resron Conducted low frequency test were conducted in accordance with [ACS URE10, DNV standard for certification No.2.4. 3.8.1 Test Condition Test Standard DNV standard for certification No.2.4 JACS URE10 DNV standard for certification No.2.4 Test Method ACSURENS Test Date December 23, 2013 Temperature/Humidity/Pressure (21.8 + 1) °C/ (31.0 + 1) % R.H./ 101.7 kPa 3.8.2 Test Equipment List Equipment Type | __ Model Manufacture | SerialNo | Cal Due Date | Use Arbitrary Generator HMF2525 HAMEG 1757816 2014.07.19 w Power Amplifier 7BSST2 BRYSTON | 002606 N/A ® Voltmeter URES R&S 101089 2014.04.23 & RF. Capacitor 6512-406R SOLAR - 2014.07.20 | 3.8.3 Test Result of Conducted low frequency test Test Voltage > AC 440V Test Results : Complied The equipment meets the requirements. Test data sheet is follow; Test Condition Frequency Sweep range Test Voltage Result Up to 15" harmonics 10% of Un Complied (A) 15" to 100" harmonics Decreasing from 10% to 1% of Un Complied (A) 100" to 200" harmonics 1 of Un Complied (A) Remarks ‘The EUT complies with the performance requirement during and after the test EUT operated normal performance within limits specified by the manufacturer. 885 roa Coa4__| 4,180 lfPbeor- Gunes Genego. in accordance with the ey of SE Gea Sont Gaede Suvaties)Report No. SGS-E13.0160 Rev.1 Page 38) a4 3.8.4 Photographs of Conducted low frequency test Configuration 808 Kors o,s__| LS ltbeongi Gung Gyargp ce, Korea restoReport No.: SGS-E13.0160_Rev.1 3.9 Power supply variation test Power supply variation test were conducted in accordance with [ACS URE10, DNV standard for certification No.2.4 3.9.1 Test Condition DNV standard for certification No.2.4 Test Standard aes URETG _ DNV standard for certification No.2.4 Test Method = 1ACS URE10 Test Date December 23, 2013 test condition : Frequency #5 % / Voltage: £10 % (15 min) Test Value test condition : Frequency +10 %, 5 s/ Voltage: #20 % (1.5 s) ‘Temperature/Humidity/Pressure : (21.5 + 1) °C /(32.0 + 1) % RH. / 101.7 kPa 3.9.2 Test Equipment List Equipment Type Model | Manufacture | SerialNo | Cal Due Date | Use PROGRAMMABLE | yesF-s1000 | YES POWER | YPMot-035 | 2014.03.12 | Ba S58 KeraCoJud | 1S tmeongl Gunpos, EstonReport No SGS-E13.0160_Rev.t Page 40 / 44 3.9.3 Test Result of Power supply variation test Test Voltage : AC 440V Test Results : Complied The equipment meets the requirements. Test data sheet follows. ” 4, — Result (performance Variations Level Test time Criteria criteria) Frequency +5 % / Voltage +10 % 15 min A Complied (A) Frequency +5 % / Voltage -10 % 45 min A Complied (A) Frequency -5 % / Voltage +10 % 45 min A Complied (A) Frequency -5 % / Voltage -10 % 415 min A ‘Complied (A) Frequency duration =5 sec : Frequency +10 % / Voltage +20 % Voltage duration A Complied (A) =1.5 sec. Frequency duration =5 sec Frequency -10 % / Voltage -20 % Voltage duration A Complied (A) =1.5 sec Remarks The EUT complies with the performance requirement during and after the test in accordance with the EUT operated normal performance within limits specified by the manufacturer. Sores Co | {So teongh Gump's Gyorgy do<-MOren 1422314785700 148251427 2590_wwwsgsgrounk Member of S65 GupSocit Strode Sinelies stonReport No: SGS-E13-0160 Rev.1 Page: 41 / 44 3.9.4 Photographs of Power supply variation test Configuration ‘SoSKeres Cott woken 1231 smn £58231 stot entero SE GralSoo Gila de Sines),SGS Report No. SGS-E18.0160_Rev.1 Page af ad 3.10 External Power Supply Failure test External Power Supply F: for certification No.2.4. 3.10.1 Test Condition Test Standard ‘ilure test were conducted in accordance with IACS URE10, DNV standard DNV standard for certification No.2.4 IACS URE10 DNV standard for certification No.2.4 eee IACS URE10 Test Date December 23, 2013 Voltage 100% Interruption (30sec) Test Value (3 interruptions within a 5-minute period) Temperature/Humidity/Pressure —: (21.51) °C/(32.04 1) % RH./ 101.7 KPa 3.10.2 Test Equipment List Equipment Type Model Manufacture | SerialNo | CalDue Date | Use PROGRAMMABLE CV.C.F YESF-31000 | YES POWER | YPMO1-035 | 2014.03.12 g resront SOSKorea Cott 418-0 eteong Gung GyeongeReport No: SGS-£13-0160_Rev.1 Page e446 3.10.3 Test Result of External Power Supply Failure test Test Voltage : AC 440V Test Results : Complied The equipment meets the requirements. Tost data sheet follows. Nominal voltage interruption Duration Times Result 3s ied = 308 (during 5 minutes) | Complied Remarks The EUT complies with the performance requirement during and after the test in accordance with the EUT operated normal performance within limits specified by the manufacturer. Note1) The EUT is power off during the test. After the test, the EUT is normal operating with the operator's intervention. 3.10.4 Photographs of External Power Supply Failure test Configuration 123 4285700 £48231 477 2170_wwrwspsroup — 85SkoresCo.ti_| 180 een gi Gunns Gyorep ta EstonReport No SGS-£13-0160_Rev.4 Page re) |4. EUT Photographs [EUT) Wo % 41S eongi Gump's, Gyeoggid, <9 Kares 148021408570 148031 427 Z70_wwwssyrcup Tesrom ‘entero SES GupSoo ial a Suanresto Report No: SGS-E13.0152_Rev.1 Page 114 Electromagnetic Compatibility Test Report Reference No.: TON-R13-1765 Applicant : Techeross Co., Ltd. 84 Yeonginsan-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833, Manufacturer : Techcross Co., Lid 84 Yeonginsan-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833 Product name : PRU Model name. : POWER RECTIFIER UNIT Serial number: PRU2013-0008 ‘Standard: DNV standard for certification No.2.4 IACS URE10 Date Reissue: June 05, 2015 Date of Receipt: October 29, 2013 Test Period : November 21, 2013 ~ November 26, 2013 Test Result : Complied Vet = tart Stolen Tested by : ee A Approved by: =e Jay Cho#7 EMC Engineer Paul Kang /Technical Mani STE) SGS Korea Co., ‘hs sorinat sms ye Corony sujet tot Gane Conon ct Seuss ste ovate. naahleo age or coe wc conien in ‘Mecsas ano kay Coortenion te cin anes ais ae foyer ts orton sane at eloenbon cones elon hese Comer Seas aw tne ost ey a traits of Chants rats ay The Campers reponse Gn a hs dcr oe ‘Score pre oavuracion fas eersang a erates cette una fe Usancbn decarris Ts ecumed ere bape wel hon pr ee ora he Cansany Ary uneuoeea alate etenon oe crn 0 apes his Sarena wt and orate may oe pcan oe ee! ‘Het! alow Unions amore Hata he reat show ith lat fopot elet ey to he samaea)osles rd sucr samples) are rae fer 60 ays Oy TOF-510-001 S6SKore8Co,le_| 4 LS-0 tbeon woKores 1462512050 ebro S68 ruplSot in sza_wReport No: SGS-£13-0182_ Rev.t stm Page 21 44 Revisions Rev No. Details Date 0 Feb. 04, 2014 Delete yellow shaded mark on 26 Page Correct the test equipment on 31, 33, 39,and 42 Page Correct the test result table on 31, 34 and 37 Page Correct the test method on 37 Page Correct the test photograph on 38 Page Correct the test voltage on 43 Page Jun. 05, 2015 6S Kore Co, J. Gung $year 4500 KresReport No: SGS-£13.0152_ Rev Page 31 48 Term TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 2. GENERAL INFORMATION OF TEST 3.1 CONDUCTED EMISSION TEST 3.2 RADIATED EMISSION TEST 3.3 ELECTROSTATIC DISCHARGE IMMUNITY TEST 3.4 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST 3.5 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 3.6 SURGE IMMUNITY TEST 3.7 CONDUCTED IMMUNITY TEST 3.8 CONDUCTED LOW FREQUENCY TEST 3.9 POWER SUPPLY VARIATION TEST 3.10 EXTERNAL POWER SUPPLY FAILURE TEST 4, EUT PHOTOGRAPHS 808 KoreeCo.ls_| 4,180 bean 13 25 28 31 33 35 37 39 42 44Report No: SGS-E13-0152 Rev-t Page: 4 / 44 1. General Description of EUT 1.1 Applicant Company Name : Techeross Co., Ltd. Address + 84 Yeonginsan-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833 1.2 Manufacture Company Name : Techeross Co., Ltd. Address : 84 Yeonginsan-ro, Inju-Myun, Asan-Si, Chungcheongnam-do, Korea 336-833 1.3 Basic Description of EUT Product Name : PRU Model Name : POWER RECTIFIER UNIT Serial Number; PRU2013-0008 Rated Voltage: AC 440 V, 60 Hz Test Voltage: AC 440 V, 60 Hz ston ‘SESKoreeCo,tth_| 4 LSro Miwon gl Surg si jeans, O0 Kor 148231 TASTED 148231 427 2310_wwrsoeproupe ember SES Gr poo ree de Sees)Report No: SGS-E1340152_ Rev. Page 51 48 2. General Information of Test 2.4 Test Facility This test was carried out by SGS Korea. Test Site Location : 23, Giheungdanji-ro 24beon-gil, Giheung-gu, Yongin-si, Gyeonggi-do, Korea TEL : 82-31-548-0712, FAX : 82-31-548-0719 2.2 Standard for Methods of Measurement Basic Standard Description Test Result © Complied 3.1 Conducted Emission CFail aaatt & Complied 3.2 Radiated Emission Beat : Complied 3.3 Electrostatic Discharge Immunity Test Fail 3.4 Radiated, radio-frequency, [3] Complied electromagnetic field immunity test C Fail DNV standard for certification | 3-5 Electrical Fast Transient/Burst Immunity | D2] Complied No.2.4 Test O Fail XI Complied JACS URE10 3.6 Surge Immunity Test Aes 3.7 Conducted Immunity Test Complies Fail 3.8 Conducted low frequency Test a eae 3.9 Power Supply Variation test Complies Complied 3.10 External Power Supply Failure test Dra 21427 270_wusesprou ‘SSKoreaCo,th | 4 180 tbeeng Surges yeongi de 5-09 Kron 198251 4285 rer 05 Galen Gna GeSiiocelReport No SGS-E13-0152_Rev.1 Page 61 48 2.3 Description of EUT modification NIA 2.4 Variations covered by this report NIA 2.5 Additional information related to Testing Test results apply only to the particular sample tested and functionality described in this test report. This report may be reproduced in full. Partial reproduction may only be made with the written permission of the SGS Korea. 2.6 Test Conditions EUT Operating Mode Operation Modes Worst Case Mode Normal Operating Mode ww 2.7 Immunity Method : Display & operating condition check. [The EUT shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed, as defined in the relevant equipment standard land in the technical specification published by the manufacturer. [The EUT shall continue to operate as intended after the test. No degradation of iperformance or loss of function is allowed, as defined in the relevant equipment standard, land in the technical specification published by the manufacturer. [During the test, degradation or loss of function or performance which is self-recoverable Is however allowed, but no change of actual operating state or stored data is allowed. [Temporary degradation or loss of function or performance is allowed during the test, provided the function is self-recoverable, or can be restored at the end of the test by the loperation of the controls, as defined in the relevant equipment standard and in the technical [specification published by the manufacturer. ‘80S Keres Cot resr00,Roport No: SGS-£13.0152_ Rev Pe 7 1 44 ‘Test System layout on EUT and peripherals —— Power cable, Interface cable AC 440 V 60 Hz EUT LOAD Device from 2.10 Modifications - N/A Test 2.9 Description of Test System Type of Cables Used: ‘SoS Korea Coe, ‘Type of shieldRoport No: SGS-E13.0152 Rev Page B44 T 3.1 Conducted Emission Test In the range of 10 kHz to 30 MHz the conducted emission was measured in accordance with DNV standard for certification No.2.4. An artificial mains V-network in accordance with CISPR 16-1 is used to provide a defined impedance at high frequencies across the terminals of the EUT. The measuring bandwidth in the frequency range 10 kHz to 150 kHz is 200 Hz, and in the frequency range 150 kHz to 30 MHz is 9 kHz. The power input cables between the a.c. and d.c. power ports of the EUT and the artificial mains network is screened and not exceed 0.8 m in length. Measurements is made with all measuring equipment and the EUT mounted on, and bonded to, an earth plane. For further description of the configuration refer to the picture of the test set-up. 3.1.1 Test Condition Frequency Range of Test 10 kHz to 30 MHz Test Standard : DNV standard for certification No.2.4 IACS URE10 Test Date November 22, 2013 Temperature/Humiaity + (20.8£1)°C / (39.041) % RH./ 100.9 kPa Input Voltage : AC 440V 3.1.2 Test Standard. Frequency Range Item (Me) 0.01 ~ 0.15 Conducted = 5) Emission bilge 0.5~ 30 3.1.3 Test Equipment List. Equipment Type Model Manufacture | SerialNo | Cal Due Date | Use EMI Test Receiver Esus R&S 100128 2014.01.25 w@ 2-LINE V-NETWORK | ENV216 Ras 100415 | 2014.00.21 | RTEICAE MAN ESH2-25 Ras too1es | 20140711 | & w NETWORK a Shielded Room - Will Tech - : PULSE LIMITER ESH3-Z2 R&S 100283 2014.09.24 ‘588 Koee Cot Testonvesre Report No. SGS-E13.0182 Rov.t Page O71 48 3.1.4 Test Result of Conducted Emission Input Voltage : AC 440 V Test Results: Complied Test data sheet is follow; Freq. | LISN | C/L iter Line| Limit Level | Result | Margin (tz) (®) | @) | (@) (aBiv) (Bu) (ea) (98) oor | 058 | 000 | oa | ia | 1te85 | 66a 766 42.08 00s | o10 | 000 | 084 | 1 | e626 | 20 728 13.46 018 | o10 | 000 | 084 | 11 | 79.00 40.7 506 28.40 142 | 020 | 004 | 9a5 | 1 | 73.00 423 52.4 20.60 14.09 | 020 | o10 | 986 | ti | 7300 | 448 55.0 18.00 oot | oss | ooo | 984 | t2| 11883 | 707 att 37.73 006 | o10 | 000 | 984 | 2 | 6626 63.0 72.9 13.36 ote | o10 | 000 | 984 | t2 | 79.00 410) 50.9 28.10 142 | 020 | oo | 985 | 12 | 7300 | 426 527 20.30 1109 | 020 | o10 | 986 | 12 | 73.00 | 454 553 17.70 oot | 060 | 000 | os | is | 11985 | 713 ai 38.16 02 | 030 | 000 | oa | 1s | s0s05 | oso 75.0 31.95 00s | o10 | 000 | oes | 1s | 9626 | 7a 773 8.96 018 | o10 | 000 | 084 | 13 | 7000 | 377 476 31.40 142 | 020 | 004 | 985 | 13 | 73.00 a4 512 21.80 1109 | 020 | o10 | 986 | us| 7300 | 454 556 17.40 FE Reading Level + C.F 2. All modes of operation were investigated and the worst-case emissions are reported. 3. Measurement uncertainty estimated at +2.70 dB. ‘The measurement uncertainty is given with a confidence of about 95 % with the coverage factor, 2 4, See next page for measurement graph. 368 Korea Cote,Report No SGS-£13-0152 Rev.t Page: 10) 44 IEC 60045 of ISN Z5 Pre ae ae | ie | boa | pe | | in 2 350m ato obo sow oo tom 20 SOM 1 Frequency in Hz,
TEC 60845 of LGN 25 Pre = | i \ 1 i | ox | | oo | | 0] oF z aee | | 20) i toe 2 9S Hook m0 SOD DM OM MOM a OM Frequency in He
S6Skorea Cot | 4tS-o ethene Gump renga, 8540 Kuen 115231 28570 148231407 2510_wwnesospoun ke Nemec! S6S Grupo Gene eSnancd TsO
You might also like
CE-EMC Test Report
PDF
No ratings yet
CE-EMC Test Report
97 pages
EMC Test Raporu
PDF
100% (1)
EMC Test Raporu
25 pages
Dss - Shcr2311002377ev en 61851
PDF
No ratings yet
Dss - Shcr2311002377ev en 61851
63 pages
ZHT-230216001E - Jiabaida - Lithium Battery Protection Plate - JBD-SP24S004 - EN 61000-6-1, EN 61000-6-3 EMC Test Report
PDF
No ratings yet
ZHT-230216001E - Jiabaida - Lithium Battery Protection Plate - JBD-SP24S004 - EN 61000-6-1, EN 61000-6-3 EMC Test Report
33 pages
Ce Emc Test Report Icr 14500 500mah
PDF
No ratings yet
Ce Emc Test Report Icr 14500 500mah
24 pages
As-Nzs Cispr32 - BT820
PDF
No ratings yet
As-Nzs Cispr32 - BT820
27 pages
BF 888s Test Report 1
PDF
No ratings yet
BF 888s Test Report 1
27 pages
EMC Test For Energy Meter
PDF
No ratings yet
EMC Test For Energy Meter
73 pages
DC1 DC2 Cameras EMC Test Report
PDF
No ratings yet
DC1 DC2 Cameras EMC Test Report
20 pages
30us Test Report ESE Veda Total
PDF
No ratings yet
30us Test Report ESE Veda Total
13 pages
Cispr 32-2015
PDF
No ratings yet
Cispr 32-2015
115 pages
CT-800A IEC60601-1-2 - Unlocked PDF
PDF
No ratings yet
CT-800A IEC60601-1-2 - Unlocked PDF
61 pages
Certificado FCC
PDF
No ratings yet
Certificado FCC
23 pages
RELATORIO-DE-TESTES Baofeng
PDF
No ratings yet
RELATORIO-DE-TESTES Baofeng
28 pages
221 Emc
PDF
No ratings yet
221 Emc
101 pages
Battery Charger EMC Test Report
PDF
No ratings yet
Battery Charger EMC Test Report
45 pages
2912,297 Emc Reports
PDF
No ratings yet
2912,297 Emc Reports
64 pages
FCC Test Report: Attestation of Global Compliance (Shenzhen) Co., LTD
PDF
No ratings yet
FCC Test Report: Attestation of Global Compliance (Shenzhen) Co., LTD
26 pages
Ce p55 Unlocked
PDF
No ratings yet
Ce p55 Unlocked
68 pages
EMC Test Report For AN5161-CGF
PDF
No ratings yet
EMC Test Report For AN5161-CGF
20 pages
Test Report 4529625
PDF
No ratings yet
Test Report 4529625
28 pages
Test Report: Electromagnetic Compatibility EMC
PDF
No ratings yet
Test Report: Electromagnetic Compatibility EMC
15 pages
19021-41400emc VR4
PDF
No ratings yet
19021-41400emc VR4
60 pages
Ce Emc Test Report Shining 3d Battery
PDF
No ratings yet
Ce Emc Test Report Shining 3d Battery
51 pages
TH-9800 - RF Test Report
PDF
No ratings yet
TH-9800 - RF Test Report
43 pages
Test Report
PDF
No ratings yet
Test Report
44 pages
DSS - GZEM210500291601-EN 55014 - Combined
PDF
No ratings yet
DSS - GZEM210500291601-EN 55014 - Combined
48 pages
FCC Test Report - 1
PDF
No ratings yet
FCC Test Report - 1
40 pages
Nx32 CE EMC Test Report
PDF
No ratings yet
Nx32 CE EMC Test Report
52 pages
RE150727C28 - AMobile - GT7800 Series - 301 908-1
PDF
No ratings yet
RE150727C28 - AMobile - GT7800 Series - 301 908-1
30 pages
Asm36 Emc Test Report Ac
PDF
No ratings yet
Asm36 Emc Test Report Ac
50 pages
CE EMC Test Report
PDF
No ratings yet
CE EMC Test Report
53 pages
210-148664 02 004
PDF
No ratings yet
210-148664 02 004
104 pages
EMC Test CISPR14 - Report
PDF
No ratings yet
EMC Test CISPR14 - Report
33 pages
GTS201811000007E01 - EMC Test Report - EN 301489-3
PDF
No ratings yet
GTS201811000007E01 - EMC Test Report - EN 301489-3
25 pages
603408-CE-EMC REPORT ANEMOMETRO Compressed
PDF
No ratings yet
603408-CE-EMC REPORT ANEMOMETRO Compressed
53 pages
HB T001Q4
PDF
No ratings yet
HB T001Q4
30 pages
PFS-30 EMC Report
PDF
No ratings yet
PFS-30 EMC Report
43 pages
CE EMC Test Report: Product Trade Mark: Model Number
PDF
No ratings yet
CE EMC Test Report: Product Trade Mark: Model Number
91 pages
FCC - Test Report: Report Number: Date of Issue: July 01, 2015
PDF
No ratings yet
FCC - Test Report: Report Number: Date of Issue: July 01, 2015
35 pages
Emc Report: Dongguan Xintai Instrument Co.,Ltd
PDF
No ratings yet
Emc Report: Dongguan Xintai Instrument Co.,Ltd
42 pages
EMC Pro1040 Pro1050 2182013 ODCùl EN
PDF
No ratings yet
EMC Pro1040 Pro1050 2182013 ODCùl EN
75 pages
Auto Punjac EMC
PDF
No ratings yet
Auto Punjac EMC
26 pages
Electromagnetic Emissions Compliance Report
PDF
No ratings yet
Electromagnetic Emissions Compliance Report
44 pages
Ctb200324016ex 紫外线消毒包 Ce Emc报告 正本 (1) Copy 2
PDF
No ratings yet
Ctb200324016ex 紫外线消毒包 Ce Emc报告 正本 (1) Copy 2
19 pages
K0024021000377-E0 英文报告 (CE) - 250219 - 104631
PDF
No ratings yet
K0024021000377-E0 英文报告 (CE) - 250219 - 104631
40 pages
Test Report
PDF
No ratings yet
Test Report
7 pages
2308 16me-A (Se-A) & 2508he-A (He-Al) Ce Test Report
PDF
No ratings yet
2308 16me-A (Se-A) & 2508he-A (He-Al) Ce Test Report
44 pages
EMC Report: Issued For
PDF
No ratings yet
EMC Report: Issued For
50 pages
Hy40 FCC
PDF
No ratings yet
Hy40 FCC
21 pages
CTB210910043REX-NB模组-EC-01F-EN 301 489-RED报告
PDF
No ratings yet
CTB210910043REX-NB模组-EC-01F-EN 301 489-RED报告
36 pages
En 301 489-1-17 - Msd30ag - 2017-03
PDF
No ratings yet
En 301 489-1-17 - Msd30ag - 2017-03
24 pages
Emc Test PDF
PDF
No ratings yet
Emc Test PDF
24 pages
Est Report: Dielectric Tests
PDF
No ratings yet
Est Report: Dielectric Tests
17 pages
Battery Test Report
PDF
No ratings yet
Battery Test Report
37 pages
Emc Test Report
PDF
No ratings yet
Emc Test Report
63 pages
Test Report SI-0672IPC
PDF
No ratings yet
Test Report SI-0672IPC
45 pages
TH-9800 - RF Exposure Test Report
PDF
No ratings yet
TH-9800 - RF Exposure Test Report
9 pages
02 -LH-240410021723-东莞市润浩科技-车载充气泵-FCC报告
PDF
No ratings yet
02 -LH-240410021723-东莞市润浩科技-车载充气泵-FCC报告
15 pages
All Flange Tables
PDF
No ratings yet
All Flange Tables
23 pages
RT Flex50 D
PDF
No ratings yet
RT Flex50 D
172 pages
Marine Anchors, Chains and Accessories
PDF
No ratings yet
Marine Anchors, Chains and Accessories
12 pages
P I Rulebook 202324
PDF
No ratings yet
P I Rulebook 202324
90 pages
Safety at AM Gent
PDF
No ratings yet
Safety at AM Gent
12 pages