Catalogo Imz Sirona

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

The IMZ Implant System

T he IMZ Implant System was developed in Germany by Dr. Axel Kirsch in the early 1970’s.
It is the only major implant system using a shock absorbing intermobile element designed
to simulate the periodontal ligament.

■ IMZ Original 3.3 & 4.0 non-hex flat-top

IMZ - Original ■ IMZ Original


The original IMZ implant was manufactured in two diameters – 3.3mm and 4.0mm. The
internal thread of the 3.3mm implant is 2.4mm and the 4.0mm implant has a 3.0mm thread.
The external implant body is either titanium plasma sprayed or HA coated with hydroxalap-
petite. The IMZ implant body is no longer sold, however, IMZ restorative components, such
as the complete abutment, UMA, etc., can still be purchased from Attachments
International.

Implants Restoratively Compatible To


■ IMZ Original 3.3 & 4.0 non-hex flat-top none

Indications and Quantities of Implants recommended:


❊ Single Tooth Replacement
One implant is required. Use the IMZ Hex Head for this type restora-
tion. Not recommended with the original IMZ 3.3 or 4.0.

❊ Bridge Reconstructions
Recommended for 1 implant attached to an abutment, or for 2 or more
free standing implants using a tissue extension.

❊ Fixed / Detachable Reconstructions


Recommended for 5 or more implants on a fully edentulous arch.

❊ Bar Type Overdentures


Recommended for 2 or more implants using a UMA, complete abut-
ment or IME tissue extension, or for an implant attached to a natural
abutment.

❊ Stud Type Overdentures


Requires at least 1 implant. Whenever possible more implants should
be used.

All product names referenced herein are trademarks of their respective companies.
© 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

1
Terminology of Components

Restorative Components:
The restorative components are the elements used to fabricate a restoration that
will be connected to the implant(s). The restoration may also be attached to an
intermediate component called a tissue extension (UMA or IME) or abutment
which in turn is connected to the implant(s).

Implant Body:
The implant body is placed into the bone for approximately 4-6 months to allow for
osseointegration. The implants should not be loaded prior to osseointegration.

IMZ - Original

Tissue Extension:
The TE (Tissue Extension) also referred to as the Complete Abutment, is the inter-
mediate connector between the implant and the restoration, it may extend above
the tissue. In some instances, a TE extension is subgingival, to provide a more
esthetic restoration.

IMZ
Complete Abutment

Implant Standardization:
The UMA tissue extension was developed to standardize the many different
implant companies' components and instruments for a more economically con-
trolled inventory and for simplicity of restorative procedures. Its tapered/hexagon
fitting surface is identical, regardless of the size or type of implant employed,
while its screw-in base is implant specific.

UMA

Compatibility:
Implants Restoratively Compatible To
■ IMZ Original 3.3 & 4.0 non-hex flat-top none

All product names referenced herein are trademarks of their respective companies.
© 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

2
Impression Copings
IMZ Non-Hex 3.3 & 4.0 Compatible Analogs

IMPRESSION COPINGS
Impression copings are used to take an impression of the IME/UMA impression coping is made of titanium and is more
implant body or the tissue extension, such as the UMA, accurate than the old style plastic impression coping. For the
Complete abutment, titanium IME, or plastic IME. The IMZ-Hex Head implant, refer to the Branemark compatible
Impression Copings which fit the implant bodies are made section. When the UMA insert is used as a tissue extension,
of titanium and transfer the thread timing. The new style the standard line of UMA components is indicated.

3.3 A B

SD Small Implant Diameter IMZ 3.3


MD Medium Implant Diameter IMZ 4.0
SD MD
3.3 4.0

Description Order # Order #

Impression Copings—To Fit Implant


Impression Coping for IMZ (A) 56-300080 56-400080

Impression Copings—To Fit UMA / IME or Complete Abutments


IME / UMA Impression Coping Tapered 3.3 or 4.0 (B) 56-000080 56-000080

ANALOGS
Analogs are used for the fabrication of a master model. Complete abutment tissue extension. The new IME impres-
They are replicas of the implant body or the IME or sion technique requires only one analog.

A B SD MD
3.3 4.0

Description Order # Order #

IMZ Implant Body Analog, Brass (A) 56-300015 56-400015


IME Analog, Brass (B) 56-000015 56-000015

All product names referenced herein are trademarks of their respective companies.
© 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

3
UMA Abutment
IMZ Non-Hex 3.3 & 4.0 Compatible UMA Cylinder,
Screw & Plug (CSP)
HEALING CAPS
Healing caps are used to maintain access through tissue caps are available, both requiring the .050" hex driver:
during healing phase. They are available in various heights 1) fits directly to the implant, 2) fits on the IME or the UMA.
to accommodate tissue depth. Two types of titanium healing

4.0 A

SD Small Implant Diameter IMZ 3.3


MD Medium Implant Diameter IMZ 4.0
SD MD
3.3 4.0

Description Dimensions Order # Order #

Healing Caps—To Fit Implant


Implant Healing Cap (A) H=2.0mm 56-302120 56-402120
Implant Healing Cap H=4.0mm 56-302140 56-402140
Implant Healing Cap H=6.0mm 56-302160 56-402160
Healing Caps—To Fit IME / UMA
IME, UMA Healing Cap H=2.0mm 11-002120 11-002120
IME, UMA Healing Cap H=4.0mm 11-002140 11-002140
IME, UMA Healing Cap H=6.0mm 11-002160 11-002160
TOOLS
DDS Hex Driver .505" 11-000007 11-000007

COMPLETE ABUTMENT (TISSUE EXTENSION)


NEW STYLE
The complete titanium abutments are extensions to fit from When the UMA insert is used in place of the IME or the
the implant through the tissue, without the TIE. The Complete Abutment, then the standard line of UMA compo-
Complete Abutment combines the TIE and the IME nents are indicated.
in one unit, like the UMA. The UMA healing caps will also fit
the IME or Complete abutment.

A
SD MD
3.3 4.0

Description Dimensions Order # Order #

Complete Abutment 3.3 OH=2.5mm 56-318330 —


Complete Abutment 3.3 OH=3.5mm 56-318335 —
Complete Abutment 4.0 OH=2.0mm — 56-418320
Complete Abutment 4.0 OH=3.0mm — 56-418330
Complete Abutment 4.0 OH=5.0mm — 56-418350
TOOLS
LT / RA Handle 58-100190
LT / RA Complete Abutment Tip 58-100170
Impression Coping for IME or Complete Abutment 56-000080
Brass Analog for IME or Complete Abutment 56-000015
OH = Overall Height

All product names referenced herein are trademarks of their respective companies.
© 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066
4
UMA Abutments
IMZ Non-Hex 3.3 & 4.0 Compatible UMA, Cylinder,
Screw & Plug (CSP)
UMA ABUTMENT (TISSUE EXTENSION)
The UMA titanium abutments are extensions which fit from implant systems. The standard UMA components are indi-
the implant through the tissue, without the TIE. The UMA is cated when the UMA insert is used in place of the IME or
the most widely used universal abutment utilizing a hex and the complete abutment. For details, refer to the UMA section.
a taper. The UMA is available for most commonly available

3.3 4.0

SD Small Implant Diameter IMZ 3.3


MD Medium Implant Diameter IMZ 4.0
SD MD
3.3 4.0

Description Dimensions Order # Order #

UMA Abutment 0.5mm — 11-001405


UMA Abutment 1.0mm — 11-001410
UMA Abutment 2.0mm 11-001320 11-001420
UMA Abutment 3.0mm 11-001330 11-001430
UMA Abutment 4.0mm 11-001340 11-001440
UMA Abutment 5.0mm 11-001350 11-001450
UMA Abutment 6.0mm 11-001360 11-001460
UMA Abutment 7.0mm 11-001370 11-001470
TOOLS:
UMA Abutment Driver see UMA section
UMA Impression Coping, Tapered Non-Hex 11-000080
UMA Impression Coping Hex w/ .050" Hex Guide Pin 11-000090
UMA Brass Analog 11-000015

UMA, CYLINDER, SCREW & PLUG (CSP)


The UMA, CSP consists of a machined plastic cylinder hex hole. The hex cylinders are used for single or telescopic
or non-hex (bridge) type, a hex or slot screw, and an abutments, while the non-hex cylinders are used for bridges
occlusal plug to seal the opening of the occlusal access or overdenture bars.

A B C D E

Description Order #

UMA, CSP Hex Cyl & Hex .050" Screw & Plug (A) 11-000202
UMA, CSP Hex Cyl & Slot Screw & Plug (B) 11-000201
UMA, CSP Non-Hex Cyl & Hex .050" Screw & Plug (C) 11-000252
UMA, CSP Non-Hex Cyl & Slot Screw & Plug (D) 11-000251
UMA, Short Cylinder Only, Red (E) 11-000270
TOOLS:
UMA, Reamer Gold Handle 11-000150
UMA, Lapping Tool and Guide Pin 11-000155

Note: For Slot Screws do not exceed 10 N/cm of torque.


All product names referenced herein are trademarks of their respective companies.
© 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066
5
Titanium Posts
IMZ Non-Hex 3.3 & 4.0 Compatible Plastic Posts
Ti-Blocs
TITANIUM & PLASTIC POSTS
The direct titanium abutment posts screw into the implant (see misc. implant section). The tapered posts can be
body and are indicated for Bridge Restorations only. They altered like a preparation. Fabricate a soft tissue model
may be secured with Teflon tape, Omni-Lite or OMNI-Bond whenever preparations are made in the laboratory.

A B

SD Small Implant Diameter IMZ 3.3 SD MD


MD Medium Implant Diameter IMZ 4.0 3.3 4.0

Description Order # Order #

Direct Titanium Posts (A) 56-301200 56-401200


Direct Plastic Posts (B) 56-301100 56-401100

USE WITH:
Impression Coping 56-300080 56-400080
Implant Body Analog 56-300015 56-400015

TI-BLOC
The titanium bloc screws into the implant body and may be bloc. However, the Ti-Bloc can be prepared like a posterior
secured with Teflon tape, Omni-Lite or OMNI-Bond. The prep, thereby increasing the esthetics and comfort. It can
Ti-Bloc requires more preparation as it is a true cylindrical also be prepared to correct for divergency.

A B
SD MD
3.3 4.0

Description Dimensions Order # Order #

Ti-Bloc 3.3 small (A) ø=4.0mm 56-301210 —


Ti-Bloc 3.3 medium ø=8.0mm 56-301220 —
Ti-Bloc 4.0 small (B) ø=5.0mm — 56-401210
Ti-Bloc 4.0 medium ø=8.0mm — 56-401220

USE WITH:
Impression Coping 56-300080 56-400080
Implant Body Analog 56-300015 56-400015

All product names referenced herein are trademarks of their respective companies.
© 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066
6
Plastic Cylinders
IMZ Non-Hex 3.3 & 4.0 Compatible Screws & Guide Pins

PLASTIC CYLINDERS TO FIT IME & COMPLETE ABUTMENT


The plastic cylinders will fit the IME as well as the Complete The CSP abbreviation means that it includes the long gray
Abutment. We recommend the castable plastic cylinders as castable plastic cylinder, a screw, and an occlusal plug.
there will be no coefficiency problem or breakage around DO NOT CAST IMPLANT RESTORATIONS IN BASE
the cylinder. The cylinders use the short screws that are ALLOY (NON-PRECIOUS).
available with a slot or with a .050" hex head.

A B C D

SD Small Implant Diameter IMZ 3.3 SD MD


MD Medium Implant Diameter IMZ 4.0 3.3 4.0

Description Order # Order #

CSP (Cylinder, Screw & Plug)


CSP, Cylinder, Slot Screw and Plug (A) 56-300251 56-400251
CSP, Cylinder, .050" Hex Screw and Plug (B) 56-300252 56-400252
PARTS
Plastic Cylinder, Long for 3.3 or 4.0 (C) 56-000250 56-000250
Plastic Cylinder, Short for 3.3 or 4.0 (D) 56-000270 56-000270
Slot Screw Only 56-300051 56-400051
Hex .050" Screw Only 56-300052 56-400052
TOOLS
UMA, Reamer Gold Handle 11-000150
UMA, Lapping Tool and Guide Pin 11-000155

SCREWS & GUIDE PINS


The titanium screws and titanium guide pins are used to
fasten the restoration to the abutments.

A B SD MD
3.3 4.0

Description Order # Order #

Screws (A)
Slot Screw 56-300051 56-400051
Hex .050" Screw 56-300052 56-400052

Guide Pins (B)


Guide Pins .050" Hex 11-000062 11-000062

Note: For Slot Screws do not exceed 10 N/cm of torque.

All product names referenced herein are trademarks of their respective companies.
© 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066
7
Overdenture
IMZ Non-Hex 3.3 & 4.0 Compatible Stud Type
Attachments
OVERDENTURE STUD TYPE ATTACHMENTS
Two overdenture attachments are commonly used to directly 1 brass analog. The ORS includes 1 male, 1 retainer ring, 3
screw in to the implant – the Dalla Bona and the ORS, white and 3 red O-Rings and a brass analog. The retention
O-Ring system. Both male elements are made of titanium of the Dalla Bona female is adjustable with the
and are attached directly to the implant body. The Dalla activating/deactivating tool.
Bona includes 1 male, 1 adjustable female, 1 spacer and

A B

SD Small Implant Diameter IMZ 3.3


MD Medium Implant Diameter IMZ 4.0
SD MD
3.3 4.0

Description Dimensions Order # Order #

Dalla Bona System (A)


Dalla Bona, complete H=1mm 56-343010 56-443010
Dalla Bona, complete H=2mm 56-343020 56-443020
Dalla Bona, complete H=3mm 56-343030 56-443030
Dalla Bona, complete H=4mm 56-343040 56-443040
Dalla Bona, complete H=5mm 56-343050 56-443050
Dalla Bona, complete H=6mm 56-343060 56-443060
Dalla Bona, complete H=7mm 56-343070 56-443070

ORS, O-Ring System (B)


ORS, complete H=1mm 56-344010 56-444010
ORS, complete H=2mm 56-344020 56-444020
ORS, complete H=3mm 56-344030 56-444030
ORS, complete H=4mm 56-344040 56-444040
ORS, complete H=5mm 56-344050 56-444050
ORS, complete H=6mm 56-344060 56-444060
ORS, complete H=7mm 56-344070 56-444070

PARTS
Dalla Bona, Implant Ti Female, Spacer & Analog Fø=3.4mm 40-430002 40-430002
Dalla Bona, Ti Female & Spacer only Fø=3.4mm 99-451012 99-451012
ORS, Retainer Rings (6) H=2.0mm ø=5.1mm 99-440044 99-440044
ORS, Combo O-Rings 10 red, 10 wt., 10 blk Mø=4.5mm 99-443037 99-443037
ORS, Implant Retainer Ring, Analog & O-Rings 40-440002 40-440002

TOOLS
Bio-Torq Socket 59-100190 59-100190
Bio-Torq ORS / Dalla Bona Tip 59-100140 59-100140
LT / RA Handle 58-100190 58-100190
LT / RA ORS / Dalla Bona Tip 58-100140 58-100140
Dalla Bona Activating Tool, Blue 99-451017 99-451017
Dalla Bona Deactivating Tool, Yellow 99-451018 99-451018

Tip: If you only need the male element Dalla Bona or ORS, replace the last zero of the order number with a 3.
For example: 56-343010 is the DB Complete for IMZ 3.3. The male only is 56-343013.

All product names referenced herein are trademarks of their respective companies.
© 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066
8
Overdenture Attachments
IMZ Non-Hex 3.3 & 4.0 Compatible Bar Type
Reamers
Lapping Tools
UBS BAR SYSTEM
The UBS—Ultimate Bar System is a convenient kit designed to facilitate
the construction of implant bar retained overdentures. In designing this
system, consideration has been given to function, ease of use and prevention
of distal lift-off while allowing resiliency from the most anterior bar segment.
PPM Bar 0 degree
Applications: Indications are for bar overdentures, precision partial dentures Hader-EDS
Housings
and patient removable implant restorations.
Each system includes:
1 Hader-EDS Bar, green plastic (50mm)
6 Hader-EDS clips—2 of each retention (2 white, 2 yellow, 2 red) Hader-EDS Clips
2 Hader-EDS Housings, gold plated stainless steel
1 Hader-EDS Seating Tool
2 SwissLoc Attachments 7.5mm—adjustable to 4.0mm
2 SwissLoc Processing Jigs Hader-EDS Bar
SwissLoc Attachments
1 PPM Bar 0 degree, blue plastic (50mm) 7.5mm
1 PPM 0 degree Mandrel
1 RA 1.5mm Reamer

Description Order #
UBS BAR KIT
UBS - Ultimate Bar System 99-551000

Note: To purchase components or parts separately, refer to the respective pages in the Renew Biocare main catalog.
IMZ

REAMERS
The reamers are used to refine the internal
access hole of a castable cylinder. The reamers
also refine the seat for the head of the screw.
The Reamer fits all UMA and IMZ IME European
new style cylinders.
A
Description Order #

UMA, Reamer Gold Handle 11-000150

LAPPING TOOLS & PASTE


The Lapping tools are used with diamond polish-
ing paste to refine the fitting surface of the cast
cylinder. We recommend that you use it not more
than 5-6 times. For superior restorations, you
may want to use the 1 micron white diamond
lapping paste. The lapping tool fits the cylinders
for the Complete Abutment, IME and UMA.
B
Description Order #

UMA, Lapping Tool and Guide Pin 11-000155


Lapping Diamond Paste 40-001010

All product names referenced herein are trademarks of their respective companies.
© 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066
9
Bio-Torq Drivers
IMZ Non-Hex 3.3 & 4.0 Compatible LT / RA Insertion
Drivers
Standard Drivers
INSERTION DRIVERS Wrenches
The Bio-Torq (B-T) and LT / RA Systems were designed to Bio-Torq socket / adapter or the Bio-Torq wrenches. The LT /
facilitate the insertion of implant components. The Bio-Torq RA (latch type) tips are used with right angle handpiece
Branemark compatible insertion tips may be utilized with the type drivers.

A B C E

B-T LT / RA A B-T LT / RA B-T LT / RA LT / RA D B-T LT / RA B-T F

Description Order # Order #


Bio-Torq LT/ RA Driver

Hand Held Socket / Handle (A) 59-100190 58-100190


Slot Tip Short 59-100110 58-100110
Slot Tip Long (B) 59-100115 58-100115
.050" Hex Tip Short 59-100120 58-100120
.050" Hex Tip .Long (C) 59-100125 58-100125
.048" Hex Tip Short 59-100130 58-100130
.048" Hex Tip Long 59-100135 58-100135
.9mm CS Hex Tip Short 59-100200 N/A
Complete Abutment Tip (D) N/A 58-100170

IMZ
UMA Tip Short (E) 59-100150 58-100150
UMA Tip Long 59-100155 N/A
Bio-Torq Extension 59-100195 N/A

Note: For Slot Screws do not exceed 10 N/cm of torque.

STANDARD DRIVERS, B-T WRENCHES & LT / RA DRIVER

A B C

Description Order #

Standard Drivers
DDS .050" Hex Driver (A) 11-000007
DDS Slot Screwdriver (B) 11-000005
Lab .050" Hex Driver (C) 11-000006

BIO-TORQ Wrenches & LT / RA Driver


BIO-TORQ Wrench 10 N/cm 59-100010
BIO-TORQ Wrench 20 N/cm 59-100020
BIO-TORQ Wrench 30 N/cm 59-100030
LT / RA Driver 58-100000

All product names referenced herein are trademarks of their respective companies.
© 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066
10