NATIONAL ASSESSMENT AND CERTIFICATION ARRANGEMENTS
3. Assessment shall focus on the core units of competency. The basic and common
units are assessed concurrently with the core units.
ELCEIM215-0917 1
Electrical Installation and Maintenance NC II
TESDA-OP-QSO-02-F01
EVIDENCE PLAN
Performing roughing-in activities, wiring and cabling works for
single-phase distribution, power, lighting and auxiliary systems
Units of
Install Electrical Protective devices for distribution, power,
Competency
lighting, auxiliary, lightning protection and grounding system
covered:
Install Wiring Devices of Floor and Wall Mounted Outlet
Lighting Fixture/Switches and Auxiliary Outlets
Ways in which evidence will be collected (tick the column)
Observation with
Oral Questioning
Demonstration /
Written test
The evidence plan must show that the candidate ….
Performing roughing-in activities, wiring and cabling works for single-phase
distribution, power, lighting and auxiliary systems
Communicates and confirms instructions for the preparation
X
of work activity to ensure clear understanding*
Interprets electrical plan and detailed drawing* X X
Identifies and checks to ensure that tools, equipment and
X X
personnel protective equipment needed to electrical system*
Identifies and checks auxiliary equipment, if it works correctly
and are safe to use in accordance with established X X
procedures*
Uses safety harness or PPE properly* X X
ELCEIM215-0917 2
Electrical Installation and Maintenance NC II
Install Electrical Protective devices for distribution, power, lighting, auxiliary,
lightning protection and grounding system
Communicates and confirms instructions for the preparation
X
of work activity to ensure clear understanding*
Interprets electrical plans and detailed drawing* X X
Identifies and checks to ensure that tools, equipment and
personnel protective equipment needed to electrical system
X
and by auxiliary equipment works correctly and are safe to
use in accordance with established procedures*
Follows safety procedures and the use of safety harness* X X
Performs correct procedures for the installation/mounting
configuration of electrical protective devices and grounding X X
system*
Responds to unplanned events or conditions accordingly* X X
Selects the types of lighting fixture and auxiliary outlet for the
X
installation*
Undertakes ongoing checks of quality of work in accordance
X X
with instructions and requirements*
Terminates/Splices conductors/wires in accordance with the
X
existing electrical standards*
Performs final checks to ensure that work conforms to
X
instructions and drawing/diagram. *
Performs installation economically* X
ELCEIM215-0917 3
Electrical Installation and Maintenance NC II
Lays out, mounts and installs electrical components, wiring
materials such as conduit and fittings in accordance with X X
standards*
Installs wiring protective devices and grounding system
X X
properly*
Installs different types of lighting fixtures/switches as per
X X
wiring diagram*
Follows work schedule to ensure job is completed on time in
X X
accordance to a quality standard and minimum wastage
Seeks further instructions from immediate supervisor in case
X X
of unplanned events or conditions occurring*
Undertakes with strict compliance ongoing checks of quality
X X
of the work in accordance with instructions and requirements
Performs installation economically* X X
ELCEIM215-0917 4
Electrical Installation and Maintenance NC II
SPECIFIC INSTRUCTIONS FOR THE COMPETENCY ASSESSOR
1. Prepare and make available the attached list of tools, equipment and materials,
instruct the candidate to perform the following tasks in accordance with the set
performance criteria:
2. You will choose which of the two sets of demonstration (SET A or SET B) will be
assigned to the candidate.
3. Allow the candidate to get familiar with the resources to be used in the assessment
for 15 minutes.
4. Observe the candidate while performing the required tasks. You may, at any
suitable point, instruct the candidate to stop, and if situation warrants, advise
him/her not to continue further with the demonstration.
During and after the candidate’s performance, assessor may perform oral
questioning to test the candidate’s knowledge and skills on actual procedures and
installation.
6. At the end of the assessment, you shall provide the candidate feedback on the
assessment result. The feedback shall indicate whether the candidate is:
COMPETENT
ELCEIM215-0917 5
Electrical Installation and Maintenance NC II
SUGGESTED QUESTION AND ACCEPTABLE ANSWERS FOR
DEMONSTRATION/OBSERVATION WITH ORAL QUESTIONING
Answers The different types of conduit commonly used for building wirings are:
metallic non-flexible conduit- such as RMC, IMC and EMT Conduit
metallic flexible conduit
Non-metallic non-flexible conduit such as PVC Conduit
Non-metallic flexible conduit
2. What is the purpose of providing a pull boxes and gutter?
Answers:
Hard hat
Gloves
safety shoes
goggles
Apron
4. What is the purpose of using electrician knife instead of using electrician pliers?
Answer: The purpose of using electricians knife are to avoid nicking of wire or lessens
the number of strand that will cause the wires heat-up
Answer: It is necessary to used rubber tape for insulating barred conductor first because
rubber it does not absorb much moisture when exposed.
ELCEIM215-0917 6
Electrical Installation and Maintenance NC II
6. As a safety measure, why is it not advisable to use water in extinguishing electrical
fires?
Answer: The main reason is that water may transmit shock to the user.
7. What are the best move using power tools in the installation?
Answer: Inspect and test if the power tools are in good or safe to use.
Answers
Lock nut
bushing
straight connector
Condulet
Coupling
Conduit strap
Answers
Service Drop
Service Entrance Conductor
Service Equipment
Answer:
a. If you are not familiar with the installation/replacement of the selector switch,
do not attempt to do it.
b. Bring the matter to your immediate supervisor and ask for assistance.
13. A portable grinder is considered as what kind of tool?
ELCEIM215-0917 7
Electrical Installation and Maintenance NC II
14. Explain how grounding system can prevent someone from receiving an electric
shock.
Answer: Grounding system has a low resistance compared to the body. If there is a
ground current, the current will tend to flow to the lower resistance, thereby
preventing someone from receiving shock.
Answer: Fuses and Circuit breakers sense the branch circuit current which is normally
higher than the full load current. If there is an overload, fuses and circuit breakers
may not trip and will damage the load.
17. What is the advantage of a Digital meter over an analog meter?
Answer:
a. Digital Meter is more accurate than analog meter due to its electronics
components
b. Easy to Calibrate and more reliable
18. What are the tools and equipment do you need in installing pipe supports and
fittings? Name at least two (2)
Answer:
Welding Machine
Electric Drill
Electric Grinder
Small Tools (hack saw, Hammer)
Answer: Worn-out carbon brush.is the common cause of electric drill breakdown
Answer: GFCI outlet are usually installed on wet locations where a person may
experience
21. Identify the basic components of lightning protection system?
Answer:
Lightning Terminal
Down Conductors
Grounding Rod
ELCEIM215-0917 8
Electrical Installation and Maintenance NC II
22. What is the acronym of “VOM” as Multi-tester?
Answer:
V - Volt-meter
O - Ohm-meter
M - Milli-Ammeter
Install Wiring Devices of Floor and Wall Mounted Outlet Lighting Fixture/Switches
and Auxiliary Outlets
23. What are the different components of the Fire Alarm System
Answer:
Fire Alarm Control Panel
Smoke Detector
Heat Detector
Fire Alarm Bell
Manual Station
24. What are basic components of Closed Circuit Television System?
Answer:
Closed Circuit Camera
TV Monitor
Sequential Switch
Recorder
CCTV Adapter/Splitters
25. What is Video Entry Phone?
Answer: Video Entry Phone is a communication device which allows the person to
identify a visitor through picture image in a monitor.
26. Name the four (4) major parts of Door Access Control System?
Answer:
Door Lock
Control System Panel
Biometric Reader and Controller
Exit Button
27. What is the function of Motion Detection in CCTV?
Answer: It is the part of Auxiliary System that set the motion-trigger action individually for
each camera?
Answer: A diagram that show the location and actual termination of the auxiliary devices.
ELCEIM215-0917 9
Electrical Installation and Maintenance NC II
29. Explain how grounding system can prevent someone from receiving an electric
shock.
Answer: Grounding system has a low resistance compared to the body. If there is a
ground current, the current will tend to flow to the lower resistance, thereby
preventing someone from receiving shock.
30. What is the advantage of a Digital meter over an analog meter?
Answer:
Digital Meter is more accurate than analog meter due to its electronics
components
Easy to Calibrate and more reliable
ELCEIM215-0917 10
Electrical Installation and Maintenance NC II
Qualification: ELECTRICAL INSTALLATION AND MAINTENANCE NC II
1. B 11. D 21. D
2. C 12. D 22. A
3. C 13. B 23. D
4. C 14. C 24. D
5. B 15. C 25. B
6. D 16. C 26. D
7. A 17. B 27. C
8. D 18. B 28. B
9. C 19. B 29. A
ELCEIM215-0917 11
Electrical Installation and Maintenance NC II
ANSWER KEY (SET B)
1. B 11. C 21. D
2. A 12. D 22. A
3. C 13. C 23. D
4. B 14. B 24. D
5. B 15. C 25. B
6. C 16. C 26. D
7. C 17. C 27. C
8. A 18. B 28. B
9. A 19. B 29. A
1. C 11. B 21. D
2. B 12. D 22. D
3. B 13. C 23. B
4. B 14. D 24. D
5. C 15. B 25. A
6. C 16. C 26. D
7. B 17. C 27. D
8. A 18. C 28. A
9. D 19. B 29. D
ELCEIM215-0917 12
Electrical Installation and Maintenance NC II
LIST OF MATERIALS, TOOLS & EQUIPMENT
(for ten [10] Candidate)
ITEM
NO. NAME SPECIFICATION QUANTITY
ELCEIM215-0917 13
Electrical Installation and Maintenance NC II
22 Smoke detector Convensional 10 sets
Hand Tools
38 Switcher 10 pcs
SPACE REQUIREMENTS
Office 30 sq. m.
Assessment Area 90 sq. m.
TOTAL AREA 120 sq. m.
ELCEIM215-0917 14