DTMA-UMTS-12-AISG-CWA
Fullband Double Dual Duplex Tower Mounted Amplifier
(Masthead Amplifier)
• Compact line
• Double units for easy use with XPol antennas
• Supports CWA, AISG 1.1 and 2.0 (default)
• AISG setting switchable as described on page 2 Ant0 Ant1
• Suitable for antenna RET control according to AISG/3GPP standard
• By-pass mode to ensure cell operation in case of DC power down
• Built-in lightning protection
• Low weight AISG = Antenna Interface Standards Group
RET = Remote Electrical Tilt
Technical Data
Tx Characteristics
Frequency range 2110 - 2170 MHz
Insertion loss Typically 0.2 dB
Ripple < 0.1 dB
Input power (per input) < 100 W (+50 dBm) CW / < 1.6 kW (+62 dBm) peak
Intermodulation products in RX band < -117 dBm (2 Tx carriers at +43 dBm)
Node B0 Node B1
Return loss > 18 dB
Rx Characteristics RET
Frequency range 1920 - 1980 MHz
Loss in by-pass mode Typically 2.0 dB (DC OFF)
Return loss > 18 dB (DC ON)
Gain Typically 12 dB
Noise figure Typically 1.4 dB
3rd order intercept point (OIP3) Typically 30 dBm
Environmental Characteristics
Operating temperature range -40 ... +65 °C
IP rating IP67*
MTBF > 1 000 000 hours (per TMA)
EMC According to ETS 300 342-3
DC and Alarm Characteristics CWA Mode AISG Mode
Subject to alteration.
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-820
DTMA-UMTS-12-AISG-CWA
Fullband Double Dual Duplex Tower Mounted Amplifier
(Masthead Amplifier)
Subject to alteration.
936.4519b
62
33
Dimensions
93
Node B
30.7
Jack (f)
RET
62
33
Earth screw M8
83.3
71.6
93
59
ANT
280
191
256.1
9
15
34.4
34.4
15
9
Jack (f) 7-16
ANT
31 7
40
59
93
71.6
256.1
83.3
191
280
300
33
62
Subject to alteration.
30.7
138
936.4519b
93
33
62
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-820
DTMA-UMTS-12-AISG-CWA
Fullband Double Dual Duplex Tower Mounted Amplifier
(Masthead Amplifier)
Blockdiagram
Mounting Instructions
The coupling torque at 7-16 connectors is 25 – 30 Nm! The tightning torque for fixing the KATHREIN tower mounted amplifiers are designed to operate under the environmental
AISG connector must be 0.5 – 1.0 Nm (‘hand-tightened’). conditions as described in ETS 300 019-1-4 class 4.1E and have passed environmental
tests as specified in ETS 300 019-2-4. The homogenous design of KATHREIN‘s tower
Subject to alteration.
It is recommended to install the DTMA’s with the antenna connectors pointing upwards and mounted amplifiers use identical modules and materials. Extensive tests have been
the BTS connectors pointing downwards. performed on typical samples and models.
In case of DTMA’s with RET-connectors (Remote Electrical Tilt-connectors according to The installation team must be properly qualified and also be familiar with the relevant
AISG Standard) it is recommended to mount the DTMA’s in such a way that the RET- national safety regulations.
connector always points downwards! A downward slanted mounting position between the
vertical and horizontal plane is also allowed. The details given on our data sheets have to be followed carefully
when installing the antennas, filters, combiners, amplifiers and
AISG Setting accessories.
The protocol of the software interface can be switched between AISG 2.0 / 3GPP and The limits for the coupling torque of RF connectors, recommended
AISG 1.1 and vice versa with a vendor specific command (depending on default setting). If by the connector manufacturers must be obeyed.
the primary station does not support the default setting, it has to be switched over before
system start-up. Please contact Kathrein for further information. Any previous datasheet issues have now become invalid.
936.4519b
Please note
The DTMA is not designed for permanent operation under water. Test conditions for the
IP68 rating: Submerge depth 1 m, submerge time 1 hour.
As a result of more stringent legal regulations and judgements regarding product liability,
we are obliged to point out certain risks that may arise when products are used under
extraordinary operating conditions.