Vessel Cat

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Distributed by

VESSEL Co., Inc.


17-25, Fukae-Kita 2-chome, Higashinari-ku, Osaka 537-0001 JAPAN
Tel : +81(0)6 6976 7778 Fax: +81(0)6 6972 9441

VESSEL EUROPE 19110121.003

6, avenue du 1er Mai, ZAE Les Glaises, 91120 Palaiseau FRANCE ●Product specifications, dimensions, pricing, and other information are
Tel: +33(0)1 69 19 17 42 Fax: +33(0)1 69 19 42 20 subject to change without notice.
●Static electricity erasing capability values given in this catalog were obtained in
OU『measurement environment.
E-mail : [email protected] URL : www.vessel.eo.jp/english Your results may differ depending on the operating environment
11
Ion parts cleaner IPC CLEAN Power supply units

High power bar Power Supply units supporting 100 to 240 VAC
For highly charged or fast moving products
SH-G3
SJ-series*

SJ-20 EDP No.621591 SJ-120 EDP No.621595


SL-30 EDP No.621592 SJ-150 EDP No.621596
SL-50 EDP No.621593 SJ-180 EDP No.621597
SJ-80 EDP No.621594
* Note
SJ-** is available while stocks last. The model code will be changed to SL-** afterward.
(Example) Specifications
SJ-20 → SL-20
SJ-EC2.5 → SL-EC2.5 Model No. SH-G3
Ionizing method/Applied voltage AC corona discharge / 5kV

Decay time
Optional High Voltage Power Unit and Branch Box Power supply 100V-240V AC ±5%

AC corona within +/- 50V 1 sec. or less


enable the use of multiple ionizing bars. HxWxD 61 x 138 × 200 mm (without protrusions)
discharge (measured 1000 mm) (measured at 300 mm) Weight 1.5 kg
1 x High Voltage Power Supply Unit (No.GP-1) can be directly
connected to max.2 ionizing bars. In addition, 3 ionizing bars in total
Power supply Air pressure
No.GP-1 4kV max. 0.3 MPa can be connected when Branch Box (No. SH-SP2) is used.
Connecting Cable SJ Bar
Connecting Cable
(GP-EC)
Compact and slim design (SJ-EC)
Power supply units
Detachable and replaceable discharge needles SH-SP2
Detachable high voltage cable
Wide variety of sizes High Voltage Power Supply Unit
Connecting Cable
Brackets enable to change the installation in angle GP-1 4kV SJ Bar

GP-1 4kV
AD24-GP or AD24-GPE (GP-EC)
Fine ionizing adjustment control with the GP-1
※The maximum cable length is 10m in total. If you require more length please contact us. Power input connector

Specifications Alarm output terminals


Anomaly detection sensitiveness
adjusting volume Power lamp (Blue LED)
Model SJ- 20 / SL- 30 / SL- 50 / SJ- 80 / SJ- 120 / SJ- 150 / SJ- 180*
Ion balance adjusting volume
Ionizing method/ Applied voltage AC corona discharge / 4 kV
Power Supply High Voltage Power Supply No.GP-1 4kV(Option) Output monitor terminals

Ion Balance Within ±50V (measured at 1,000mm, at air pressure 0.3MPa) Power switch
40
Decay Time 1 second or less (measured at 300mm, at air pressure 0.3MPa) 102.8
7 7
Operating Distance 50 ∼ 2000mm 96

6.5
11.75
Ozone production 0.05ppm or less (measured at 50mm from the discharge needle)
Air Connection PT1/8, with one-touch joint
SJ-80 or smaller: Hose O.D.6mm x I.D.4mm
Air hose
SJ-120 or larger: Hose O.D.8mm x I.D.6mm
Operating Fluid Clean dry air or Nitrogen gas (0.3MPa or less)
5 ∼ 50℃ 35 ∼ 85%RH (without freezing or dew condensation)

220.5
Operating Environment

233.5
210
Accessories Ground wire, Instruction manual
EDP No. 623044
Options
A Specifications
B
C 16 2 Connecting cable (2.5m) Connecting cable (5m) Model GP-1 4kV 3.7

GP-EC2.5 GP-EC5 Operating Temp./Humidity 0 ∼ 50℃/10 ∼ 90%RH(without freezing or dew condensation) 19


1.5

EDP No. 623053 EDP No. 623054 Storage Temp./Humidity -30 ∼ 70℃/10 ∼ 95%RH(without freezing or dew condensation)
33
30

Mounting leg 60
Installation Place Indoors portion 21.4
30 Grounding terminal
F Rated Input Voltage 24V DC±10%
Branch Box Connecting cable (2.5m) Connecting cable (5m)
(30) D 60 19
SH-SP2 SL-EC2.5* SJ-EC5* Variable Output Range AC output 4kV

28
36
9 P40 Without Loud (rms) DC output -150 to +550V
EDP No. 621552 EDP No. 623051 EDP No. 623052

114.2
Secondary Short Circuit Current 5 mA or lower
36.4

Output Monitor 1/1000V±5% of the output voltage is emit to the monitor terminals. Option
23

27
30

Needle electrode
E
(mm) SJ-00HR* Low-voltage Detection
Anomaly detection function will operate when each output drops to about 85%
or less of the set voltage due to high voltage short circuit or abnormal sparks. Adapter specification
6.7

EDP No. 623055


Anomaly detection function will operate when the output current is ●… ●… High voltage output connectors
Dimensions / Needle Electrodes Overcurrent Detection
about 4mA or more.
Model No.* A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) Needle Electrode Weight (kg) Anomaly Detection The anomaly detection response speed can be adjusted AC Adapter
Sensitivity Adjustment (using external adjustment knob)
SJ-20 174 170 138 80 190 208 3 pcs 0.2 AD24-GP
SL-30 334 330 298 240 350 368 7 pcs 0.3 Power Supply Input Molex 5569-04A1-210 ● EDP No. 806049
High Voltage Output Connector Ceramic high voltage output terminal×2 AD24-GPE
SL-50 494 490 458 400 510 528 11 pcs 0.7
Alarm Output Terminal C contact relay output ● EDP No. 806048
SJ-80 814 810 778 720 830 848 19 pcs 0.9
Switches And Displays On-off rocker switches. Blue LED power indicator lamp (goes off when anomaly is detected) I / P : AC100V~240V 0.4A
SJ-120 1,134 1,130 1,098 1,040 1,150 1,168 27 pcs 1.1 Material Housing SPCC, painted white
O/P : DC24V 0.75A

SJ-150 1,454 1,450 1,418 1,360 1,470 1,488 35 pcs 2.0 Size W102.8×D233.5×H114.2mm
SJ-180 1,774 1,770 1,738 1,680 1,790 1,808 43 pcs 2.2 Weight Approx. 4.5kg

21 22