330C EXCAVADORA Sistema Implemento
330C EXCAVADORA Sistema Implemento
Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.
EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.
CHECK
ACCUMULATORS Unidirectional Bidirectional Control Line Restriction
Valves (Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)
Unidirectional Bidirectional
MAIN AUX.
PILOT CONTROL
Line Restriction 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump
Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated
COMBINATION CONTROLS
LINES MEASUREMENT
Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow
Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
111-7898 3E-5179
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.
Part Number: for 1
Connector Plug
2
Ground (Wired): This indicates that the component is connected to a grounded wire.
The grounded wire is fastened to the machine. Receptacle
Plug
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
It is grounded by being fastened to the machine.
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it. 325-AG135 PK-14
Harness identification code:
The electromagnet can open or close the switch part of the relay. Wire Gauge*
This example indicates wire group 325,
wire 135 in harness "AG". Wire Color
Solenoid: A solenoid is an electrical component that is activated by electricity. *Wire gauge is shown in AWG (American Wire Gauge)
It has a coil that makes an electromagnet when current flows through it. but could also be shown in metric denoted with mm
The electromagnet can open or close a valve or move a piece of metal that can do work. Deutsch connector: Typical representation
1
of a Deutsch connector. The plug contains all
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a 2 sockets and the receptacle contains all pins.
permanent magnet. It has two coils (latch and unlatch) that make electromagnet Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places 1
of a Sure-Seal connector. The plug and receptacle
the latch coil circuit open at the time the coil latches. 2 contain both pins and sockets.
RENR5489-02
September 2020
© 2020 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Yellow,” the “Power Edge”
and Cat “Modern Hex” trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION
Schematic Machine
Component
Location Location
Relay - Thumb Closed (Attachment) E-6 1
Relay - Thumb Open (Attachment) E-7 2
Solenoid - Thumb Open (Attachment) B-2 3
Solenoid - Thumb Close (Attachment) C-2 4
Switch - Hammer Pressure (Attachment) B-5 5
CONNECTOR LOCATION
Schematic Machine
Connector Number
Location Location
CONN 101 D-5 6
CONN 102 D-4 7
CONN 103 D-3 8
CONN 104 D-2 9
F7 F6 F5 F4 F3 F2 F1
308-YL
E7 E6 E5 E4 E3 E2 E1
308-YL D 308-YL D T715-WH-18
K848-WH-18
E472-GN-18
E474-OR-18
E472-GN-18
K843-GN-18
K844-GY-18
K847-PU-18
E473-GY-18
149-5050
235-BK-18
T715-WH-18
T713-GN-18
T714-BU-18
T716-PK-18
T715-WH-18
T713-GN-18
235-BK-18
D7 D6 D5 D4 D3 D2 D1
D D
2 1 4 3 A B C CONN 101
A,B,C
K852-GN-18
893-GN-18
K850-BR-18
K851-BU-18
892-BR-18
K849-YL-18
C987-RD-14
151-GN
308-YL
1 2 3 4 5 6 CONN 102
A,B,C
RELAY PANEL
HARNESS
K849-PK-18
A,B,C
PLATFORM
C7 C6 C5 C4 C3 C2 T716-PK-18
200-BK-18
A,B,C
1
2
C1
(4) ATCH THUMB
CLOSE SOL
121-1491
A,B,C
T714-BU-18 1 (3) ATCH THUMB
A,B,C 200-BK-18 2 OPEN SOL
2 235-BK-18 121-1491
1 K849-YL-18
23
18
5-
K-
BK
B
-1
0-
(5) ATCH HAMMER 18
B7 B6 B5 B4 B3 B2 B1
8 BK-
20
PRESS. SWITCH -
167-3466 200
CALLOUT FORMAT IF APPLICABLE
A,B,C
CHASSIS Callout Number
(Machine Location from (52) VALVE GP - CONTROL
Component
Name
Component Locations Table)
138-1234 Part Number
WH WHITE
CIRCUIT NOT CONNECTED
RENR5489-02
OR ORANGE
ELECTRICAL CONNECTION TO
MACHINE STRUCTURE
YL YELLOW
INTERNAL ELECTRICAL CONNECTION
TO SURFACE OF COMPONENT PK PINK
CONNECTOR BK BLACK
GY GRAY
WIRE GROUP COLOR DESCRIPTIONS H# CIRCUIT GROUPING DESIGNATION
PU PURPLE
GROUND CIRCUIT ATCH WIRE, CABLE, COMPONENT
BR BROWN
WIRES THAT HAVE SYSTEM VOLTAGE WHEN THE KEY SWITCH IS ON
SPLICE
RELAY OUTPUT CIRCUIT GN GREEN
MONITOR CIRCUIT BLADE, SPADE, RING OR SCREW
TERMINAL BU BLUE
ATTACHMENT VALVE CONTROL CIRCUIT
WIRES THAT HAVE SYSTEM VOLTAGE WHEN THE KEY SWITCH IS OFF
12 Page,
A7 A6 IDENT
A
B
PART NO. LOC
213-0553 (322CT2,325C)
213-0604 (330C)
A5 A4
Connector Number
Connector Location
RENR3867
Schematic
Location
RENR5393
Schematic
Location
RENR5457
Schematic
Location
RENR7086
Schematic
Location
A3
Do not operate or work on this product unless you have
read and understood the instruction and warnings in the
A2
THIS SCHEMATIC IS FOR THE 322C, 325C AND 330C EXCAVATOR ELECTRICAL SYSTEM
ATTACHMENT: SYSTEM 15: TWO WAY / ONE PUMP FLOW / JOYSTICK SWITCH
MEDIA NUMBER: RENR5489-02
A1
CONN 101 G-7 G-12 G-8 G-12 relevant Operation and Maintenance Manuals and
C 213-0534 (322C) relevant service literature. Failure to follow the instruc- SCHEMATIC PART NUMBER: 200-6642, CHANGE: 01, VERSION: HE
D 204-1954 CONN 102 D-6 E-6 D-6 E-6 tions or heed the warnings could result in injury or Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
CONN 103 I-3 I-3 I-3 I-3 death. Proper care is your responsibility. in neutral and with parking brake set.
CONN 104 H-3 H-3 H-3 H-3 Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.
MACHINE HARNESS CONNECTOR AND COMPONENT
LOCATIONS
2 1 3 4 8 5 7 9
1 2 3 4 5 8 7 9
6
CAB COMPONENT LOCATIONS
5
TOP
VIEW
View G-G
4 3
2 1
4
3
View N-N
View E-E