0% found this document useful (0 votes)
90 views8 pages

330C EXCAVADORA Sistema Implemento

This document provides instructions for setting a screen resolution of 1024x768 to properly view an interactive schematic. It explains how to right click the desktop, select properties, click the settings tab, and move the slider to 1024x768 before clicking OK. It also notes that linked schematic locations may vary between monitors and PDF readers. Basic hydraulic and electrical component symbols are shown for pumps, valves, cylinders, motors, accumulators, and more.

Uploaded by

y2npbp6fgs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
90 views8 pages

330C EXCAVADORA Sistema Implemento

This document provides instructions for setting a screen resolution of 1024x768 to properly view an interactive schematic. It explains how to right click the desktop, select properties, click the settings tab, and move the slider to 1024x768 before clicking OK. It also notes that linked schematic locations may vary between monitors and PDF readers. Basic hydraulic and electrical component symbols are shown for pumps, valves, cylinders, motors, accumulators, and more.

Uploaded by

y2npbp6fgs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

INTERACTIVE SCHEMATIC

Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.

Click here to save a copy of


EC-C2 E-C60 this interactive schematic
EC-C3
to your desktop
E-C61

VIEW ALL CALLOUTS

EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.

ELECTRICAL SYMBOLS BASIC HYDRAULIC


HOTKEYS (Keyboard Shortcuts) COMPONENT SYMBOLS
T

Pressure Temperature Level Flow


Switch Switch Switch Switch Circuit Breaker Pump
Variability
FUNCTION KEYS or Motor

Click here to view the


Spring
Zoom In “CTRL” / “+” Schematic Symbols
Fluid
Conditioner (Adjustable)

Zoom Out “CTRL” / “-” and Definitions page

Fit to Page “CTRL” / “0” (zero)


Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
Search “CTRL” / “SHIFT” / “F”
SCHEMATIC SYMBOLS AND DEFINITIONS

VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC


ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB
MOTORS
AB
Single Acting Double Acting
Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
ACCUMULATORS Unidirectional Bidirectional Control Line Restriction
Valves (Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

MAIN AUX.

PILOT CONTROL
Line Restriction 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump

Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated

Internal Hydraulic Pneumatic


Simplified Complete Supply Pressure Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).

Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
111-7898 3E-5179
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.
Part Number: for 1
Connector Plug
2
Ground (Wired): This indicates that the component is connected to a grounded wire.
The grounded wire is fastened to the machine. Receptacle
Plug
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
It is grounded by being fastened to the machine.
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it. 325-AG135 PK-14
Harness identification code:
The electromagnet can open or close the switch part of the relay. Wire Gauge*
This example indicates wire group 325,
wire 135 in harness "AG". Wire Color
Solenoid: A solenoid is an electrical component that is activated by electricity. *Wire gauge is shown in AWG (American Wire Gauge)
It has a coil that makes an electromagnet when current flows through it. but could also be shown in metric denoted with mm
The electromagnet can open or close a valve or move a piece of metal that can do work. Deutsch connector: Typical representation
1
of a Deutsch connector. The plug contains all
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a 2 sockets and the receptacle contains all pins.
permanent magnet. It has two coils (latch and unlatch) that make electromagnet Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places 1
of a Sure-Seal connector. The plug and receptacle
the latch coil circuit open at the time the coil latches. 2 contain both pins and sockets.
RENR5489-02
September 2020

322C, 325C, and 330C Excavator


Electrical System (Attachment)
BFE1-UP
BKJ1-UP
HEK1-UP
DKY1-UP

System 15: Two Way / One Pump Flow / Joystick Switch

© 2020 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Yellow,” the “Power Edge”
and Cat “Modern Hex” trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION

Schematic Machine
Component
Location Location
Relay - Thumb Closed (Attachment) E-6 1
Relay - Thumb Open (Attachment) E-7 2
Solenoid - Thumb Open (Attachment) B-2 3
Solenoid - Thumb Close (Attachment) C-2 4
Switch - Hammer Pressure (Attachment) B-5 5
CONNECTOR LOCATION

Schematic Machine
Connector Number
Location Location
CONN 101 D-5 6
CONN 102 D-4 7
CONN 103 D-3 8
CONN 104 D-2 9
F7 F6 F5 F4 F3 F2 F1
308-YL

E7 E6 E5 E4 E3 E2 E1
308-YL D 308-YL D T715-WH-18

308-YL 308-YL T716-PK-18


L.H. JOYSTICK

(2) ATCH THUMB T713-GN-18 R.H. JOYSTICK


RELAY (OPEN) T714-BU-18
149-5050
(1) ATCH THUMB
RELAY (CLOSED)

K848-WH-18
E472-GN-18
E474-OR-18

E472-GN-18

K843-GN-18
K844-GY-18

K847-PU-18
E473-GY-18
149-5050

235-BK-18
T715-WH-18
T713-GN-18
T714-BU-18

T716-PK-18

308-YL CONN 103 1 2 3 4 5 6 1 2 3 4 CONN 104


A,B,C A,B,C
CHASSIS HARNESS

T715-WH-18
T713-GN-18

235-BK-18
D7 D6 D5 D4 D3 D2 D1
D D
2 1 4 3 A B C CONN 101
A,B,C

K852-GN-18
893-GN-18

K850-BR-18
K851-BU-18
892-BR-18

K849-YL-18
C987-RD-14
151-GN
308-YL

1 2 3 4 5 6 CONN 102
A,B,C
RELAY PANEL
HARNESS

K849-PK-18
A,B,C
PLATFORM

C7 C6 C5 C4 C3 C2 T716-PK-18
200-BK-18
A,B,C
1
2
C1
(4) ATCH THUMB
CLOSE SOL
121-1491

A,B,C
T714-BU-18 1 (3) ATCH THUMB
A,B,C 200-BK-18 2 OPEN SOL
2 235-BK-18 121-1491
1 K849-YL-18
23

18
5-

K-
BK

B
-1

0-
(5) ATCH HAMMER 18

B7 B6 B5 B4 B3 B2 B1
8 BK-

20
PRESS. SWITCH -
167-3466 200
CALLOUT FORMAT IF APPLICABLE
A,B,C
CHASSIS Callout Number
(Machine Location from (52) VALVE GP - CONTROL
Component
Name
Component Locations Table)
138-1234 Part Number

SYMBOL DESCRIPTION ABBREV COLOR


(Dimensions: 25 inches x 24 inches)

CIRCUIT CONNECTED RD RED

WH WHITE
CIRCUIT NOT CONNECTED
RENR5489-02

OR ORANGE
ELECTRICAL CONNECTION TO
MACHINE STRUCTURE
YL YELLOW
INTERNAL ELECTRICAL CONNECTION
TO SURFACE OF COMPONENT PK PINK

CONNECTOR BK BLACK

GY GRAY
WIRE GROUP COLOR DESCRIPTIONS H# CIRCUIT GROUPING DESIGNATION
PU PURPLE
GROUND CIRCUIT ATCH WIRE, CABLE, COMPONENT
BR BROWN
WIRES THAT HAVE SYSTEM VOLTAGE WHEN THE KEY SWITCH IS ON
SPLICE
RELAY OUTPUT CIRCUIT GN GREEN
MONITOR CIRCUIT BLADE, SPADE, RING OR SCREW
TERMINAL BU BLUE
ATTACHMENT VALVE CONTROL CIRCUIT
WIRES THAT HAVE SYSTEM VOLTAGE WHEN THE KEY SWITCH IS OFF
12 Page,

A7 A6 IDENT
A
B
PART NO. LOC
213-0553 (322CT2,325C)
213-0604 (330C)
A5 A4
Connector Number
Connector Location
RENR3867
Schematic
Location
RENR5393
Schematic
Location
RENR5457
Schematic
Location
RENR7086
Schematic
Location
A3
Do not operate or work on this product unless you have
read and understood the instruction and warnings in the
A2
THIS SCHEMATIC IS FOR THE 322C, 325C AND 330C EXCAVATOR ELECTRICAL SYSTEM
ATTACHMENT: SYSTEM 15: TWO WAY / ONE PUMP FLOW / JOYSTICK SWITCH
MEDIA NUMBER: RENR5489-02
A1
CONN 101 G-7 G-12 G-8 G-12 relevant Operation and Maintenance Manuals and
C 213-0534 (322C) relevant service literature. Failure to follow the instruc- SCHEMATIC PART NUMBER: 200-6642, CHANGE: 01, VERSION: HE
D 204-1954 CONN 102 D-6 E-6 D-6 E-6 tions or heed the warnings could result in injury or Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
CONN 103 I-3 I-3 I-3 I-3 death. Proper care is your responsibility. in neutral and with parking brake set.
CONN 104 H-3 H-3 H-3 H-3 Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.
MACHINE HARNESS CONNECTOR AND COMPONENT
LOCATIONS

2 1 3 4 8 5 7 9

1 2 3 4 5 8 7 9

6
CAB COMPONENT LOCATIONS

5
TOP
VIEW
View G-G

4 3
2 1

4
3
View N-N
View E-E

You might also like