Bs En61192 Part 2 SMT
Bs En61192 Part 2 SMT
61192-2:2003
Workmanship
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
requirements for
soldered electronic
assemblies —
Part 2: Surface-mount assemblies
ICS 31.190
12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:
BS EN 61192-2:2003
National foreword
This British Standard is the official English language version of
EN 61192-2:2003. It is identical with IEC 61192-2:2003.
The UK participation in its preparation was entrusted to Technical Committee
EPL/501, Electronic assembly technology, which has the responsibility to:
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Summary of pages
This document comprises a front cover, an inside front cover, the EN title page,
pages 2 to 65 and a back cover.
The BSI copyright date displayed in this document indicates when the
document was last issued.
This British Standard was
published under the authority
of the Standards Policy and
Strategy Committee on
25 June 2003
ICS 31.190
English version
This European Standard was approved by CENELEC on 2003-04-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta,
Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Foreword
The text of document 91/357/FDIS, future edition 1 of IEC 61192-2, prepared by IEC TC 91, Electronics
assembly technology, was submitted to the IEC-CENELEC parallel vote and was approved by
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
This standard should be used in conjunction with the following parts of EN 61192, under the general title
Workmanship requirements for soldered electronic assemblies:
Part 1: General
Part 2: Surface-mount assemblies
Part 4: Terminal assemblies
Endorsement notice
The text of the International Standard IEC 61192-2:2003 was approved by CENELEC as a European
Standard without any modification.
__________
Page 3
EN 61192−2:2003
61192-2 IEC:2003 –3–
CONTENTS
INTRODUCTION .....................................................................................................................7
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
1 Scope ...............................................................................................................................8
2 Normative references........................................................................................................8
3 Terms and definitions .......................................................................................................9
4 General requirements .......................................................................................................9
4.1 Classification ...........................................................................................................9
4.2 Conflict ....................................................................................................................9
4.3 Interpretation of requirements ................................................................................ 10
4.4 Antistatic precautions ............................................................................................ 10
5 Component preparation processes .................................................................................. 10
6 Solder paste deposition process qualification .................................................................. 10
6.1 Solder paste characteristics ................................................................................... 10
6.2 Assessment of the process .................................................................................... 10
6.3 Solder paste deposition – Screen and stencil printing methods –
Process control limits............................................................................................. 11
7 Non-conductive adhesive deposition process .................................................................. 13
7.1 Pot life................................................................................................................... 13
7.2 Inter-stage storage and handling ............................................................................ 13
7.3 Adhesive tackiness ................................................................................................ 14
7.4 Assessment of the adhesive attachment process ................................................... 14
7.5 Adhesive deposition – Syringe dispensing method – Small components –
Process control limits............................................................................................. 14
8 Temporary masking processes ....................................................................................... 17
9 Component placement processes ................................................................................... 17
9.1 Assessment of the process .................................................................................... 17
9.2 Discrete components with gull-wing leads .............................................................. 19
9.3 IC components with flat-ribbon, L- or gull-wing leads on two sides .......................... 22
9.4 IC components with flat-ribbon, L- or gull-wing leads on four sides, for
example, quad flat packs ....................................................................................... 25
9.5 Components with round or flattened (coined) leads ................................................ 28
9.6 IC component packages with J-leads on two and four sides, for example,
SOJ, PLCC ............................................................................................................ 29
9.7 Leadless rectangular components with metallized terminations .............................. 32
9.8 Components with cylindrical endcap terminations ................................................... 35
9.9 Bottom-only terminations on leadless components ................................................. 37
9.10 Leadless chip carriers with castellated terminations ............................................... 39
9.11 Components with butt leads ................................................................................... 41
9.12 Components with inward L-shaped ribbon leads ..................................................... 44
9.13 Flat-lug leads on power dissipating components..................................................... 45
Page 4
EN 61192−2:2003
61192-2 IEC:2003 –4–
INTRODUCTION
This part of IEC 61192, combined with IEC 61192-1, is used to meet the end-product
requirements defined in IEC 61191-1 and IEC 61191-2.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
This standard may be used to enable the suppliers and users of surface-mount electronic
assemblies to specify good manufacturing practices as part of a contract.
The respective requirements for through-hole assemblies, terminal attachment and the
mounting of bare semiconductor die and carrier-mounted die, are included in separate but
related standards.
Page 8
EN 61192−2:2003
61192-2 IEC:2003 –8–
WORKMANSHIP REQUIREMENTS
FOR SOLDERED ELECTRONIC ASSEMBLIES –
1 Scope
This part of IEC 61192 specifies requirements for workmanship in soldered surface-mounted
electronic assemblies and multichip modules on organic substrates, on printed boards, and on
similar laminates attached to the surface(s) of inorganic substrates.
It applies to assemblies that are totally surface-mounted and to the surface-mount portions of
assemblies that include other related assembly technologies, for example, through-hole
mounting. It does not include metal or ceramic-based hybrid circuits in which the conductor
metallization is deposited directly on a ceramic substrate or onto a ceramic-coated metal
substrate.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 60194, Printed board design, manufacture and assembly – Terms and definitions
IEC 61191-1, Printed board assemblies – Part 1: Generic specification – Requirements for
soldered electrical and electronic assemblies using surface mount and related assembly
technologies
IEC 61191-2, Printed board assemblies – Part 2: Sectional specification – Requirements for
surface mount soldered assemblies
IEC 61191-3, Printed board assemblies – Part 3: Sectional specification – Requirements for
through-hole mount soldered assemblies
IEC 61191-4, Printed board assemblies – Part 4: Sectional specification – Requirements for
terminal soldered assemblies
IEC 61192-1, Workmanship requirements for soldered electronic assemblies – Part 1: General
IEC 61192-3, Workmanship requirements for soldered electronic assemblies – Part 3: Through-
hole mount assemblies
IEC 61192-4, Workmanship requirements for soldered electronic assemblies – Part 4: Terminal
assemblies
IEC 61193-1: Quality assessment systems – Part 1: Registration and analysis of defects on
printed board assemblies
ISO 9002, Quality systems – Model for quality assurance in production, installation and
servicing
Page 9
EN 61192−2:2003
61192-2 IEC:2003 –9–
For the purposes of this part of IEC 61192, the definitions of IEC 60194 apply.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
4 General requirements
4.1 Classification
The classification of assemblies is divided into three levels, that is levels A, B, and C.
Definitions of the classification categories and the status of product for each level are given in
IEC 61192-1. In general, status is divided into three workmanship conditions as follows:
a) target;
b) acceptable;
c) nonconforming.
4.2 Conflict
Unless the user specifies compliance with all of the requirements (or with specific items) in this
standard, for example, as part of a supply contract, the mandatory clauses and subclauses
herein may be interpreted as guidance.
When the user elects to specify compliance with all or some of the mandatory requirements of
this standard:
a) In the event of conflict between the requirements of this standard and the applicable
documents cited herein, refer to IEC 61191-1 for the relevant priorities and to IEC 61191-2
and IEC 61192-1 for technical requirements. However, nothing in this standard supersedes
applicable laws and regulations.
b) In the event of conflict between the requirements of this standard and the applicable user
assembly drawing(s) and specifications, the latter shall govern.
When the conflict is between the requirements of this document and drawing(s) or specifi-
cation(s) that have not been approved by the user, the latter shall be submitted to the user
for approval. Upon such approval, the acceptance (or changes) shall be documented,
for example, by official revision note or equivalent on the drawing(s) or specification(s)
which shall then govern.
c) Where the applicable user documentation requirements are less stringent than the appli-
cable mandatory items in IEC 61191-1, IEC 61191-2, or in this standard, neither the
supplier nor the user shall claim compliance with this or any of the standards listed in this
clause, without identifying the specific clauses and related relaxations in each and every
such claim.
Page 10
EN 61192−2:2003
61192-2 IEC:2003 – 10 –
Unless otherwise specified by the user, the word "shall", signifies that the requirement is
mandatory. Deviation from any "shall" requirement requires written acceptance by the user, for
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
The words "should" and "may" reflect recommendations and guidance, respectively, and are
used whenever it is intended to express non-mandatory provisions.
All operators using workstations and assembly or cleaning equipment and carrying out inter-
process handling shall strictly observe antistatic precautions at all times. Refer to 4.2.6 and 5.7
of IEC 61192-1.
Component preparation processes shall be carried out in accordance with the requirements of
IEC 61192-1 using the methods described therein.
Solder paste deposition processes are described in IEC 61192-1 and workmanship should
enable the requirements stated therein to be met.
Solder paste is required to maintain a level of tackiness to ensure good physical contact with
component leads or terminations and to prevent placed components from slipping or being
accidentally dislodged from the paste mound(s) during board handling or mechanized transit
into the soldering equipment. The length of time over which the paste retains adequate
tackiness is specified by the supplier and all placement operations should be carried out well
within this stated limit.
NOTE Where pastes designed to allow extended times between their deposition and component placement are
used, for example, longer than 2 h, care should be taken to ensure that the required longer pre-heat time and
temperature in reflow mass soldering are programmed. In some cases this may require physical extension of the
pre-heat zones on standard reflow soldering machines.
The parameters requiring inspection are the amount, shape and position of the solder paste on
the land patterns of the board or substrate. These are assessed using visual inspection, laser
scan, or X-ray as appropriate.
The deposited area and mean height are used to monitor the quantity of paste deposited and
act as an indicator of its viscosity and the board surface condition. The wetted area is also
used to monitor screen/stencil or syringe tip condition and the incidence of unwanted smudges.
Positional measurement assesses the accuracy of deposition and monitors machine set-up
and, if applicable, screen/stencil design.
Page 11
EN 61192−2:2003
61192-2 IEC:2003 – 11 –
The standard PPM baseline for solder paste deposition operations is the number of paste
mound deposits attempted. Guideline assessment attributes and the method of calculating
PPM are given in IEC 61193-1.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target, accept and reject (nonconforming) criteria for solder paste deposition are given as
process control limits in 6.3. These are the same for levels A, B and C.
In all cases, the accept and reject criteria shown in Figures 1 through 3 refer to the solder
paste printing operation.
Target – Levels A, B, C
1 Paste contour sits central within land area.
2 Paste cross-section is mesa-shaped.
3 Designed quantity is achieved.
Cross-section
IEC 574/03
Acceptable – Levels A, B, C
1 Paste contour slumped.
2 Overhang A is less than 25 % of the
related X or Y dimension, or 0,2 mm,
whichever is smaller.
3 Paste volume ±20 % of designed quantity.
A
Y
IEC 575/03
Nonconforming – Levels A, B, C
1 Paste quantity and/or overhang A exceeds
acceptable limits.
2 Paste overhang A is more than 25 % of
related x or y dimension or 0,2 mm which-
ever is smaller.
3 Paste quantity is more than 120 % or less
than 80 % of designed quantity.
IEC 576/03
A
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Nonconforming – Levels A, B, C
Paste quantity below acceptable limits.
Height B less than 80 % of stencil thickness.
B
Partial coverage
IEC 577/03
Nonconforming – Levels A, B, C
Smudging/smearing of solder paste.
IEC 578/03
Adhesive deposition workmanship is described in IEC 61192-1, Clause 9 and shall be carried
out in accordance with the requirements stated therein.
The time elapsed between the first exposure of the adhesive to the ambient factory
atmosphere and the start of curing should be well within the suppliers' stated maximum.
Boards that have received deposited adhesive and require brief inter-stage storage should be
handled with care to avoid component movement. Some adhesive materials cause dermatitis.
Boards stored temporarily should be kept separate and in clean, dry conditions, or as specified
by the adhesive manufacturer.
Page 14
EN 61192−2:2003
61192-2 IEC:2003 – 14 –
Adhesive is required to maintain a level of tackiness to assure good contact with placed
components prior to curing. The length of time over which the adhesive retains adequate
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
tackiness (the 'pot life') is specified by the supplier and all placement operations should be
carried out well within this stated limit. Handling should avoid the risk of component movement.
The deposited area and mean height are used to monitor the quantity of adhesive deposited
and act as an indicator of its viscosity and the board surface condition. The wetted area is also
used to monitor screen/stencil or syringe tip condition and the incidence of unwanted smudges.
Positional measurement assesses the accuracy of deposition and monitors machine set-up
and, if applicable, screen/stencil design.
Adhesive dot height, shape and volume are key parameters because if the underside of the
component does not make contact with the dot, adhesion will not occur. A suitable way of
assessing the correctness of adhesive quantity is to pull off a component after curing. Refer to
item d) of Clause 11.
When adhesive deposition equipment uses an optical view of the deposited area of the
adhesive dot to monitor its height, the deposition head and any associated time-pressure pulse
system should be kept at a constant temperature. The wetted area on the component may be
determined by examining the underside after placement and curing using a cross-section
method.
The standard PPM baseline for adhesive deposition operations is the number of adhesive dot
deposits attempted. Guideline assessment attributes and the method of calculation are given in
IEC 61193-1.
Target, accept and reject (nonconforming) criteria for small components are given as process
control limits in 7.5. These are the same for all levels.
Target – Levels A, B, C
1 Adhesive contour central within designed
area.
2 Adhesive quantity correct.
3 Cross-section not slumped or tailed.
NOTE When UV curing, design may require
adhesive to appear outside component contour.
IEC 579/03
Acceptable – Levels A, B, C
1 Adhesive placement eccentric.
2 Dot touches but does not overlap land or
component metallization.
IEC 580/03
Nonconforming – Levels A, B, C
1 Adhesive dot overlaps land.
2 Adhesive overlaps component metallization.
3 Adhesive reduces solder joint wetting
ability below specified limits.
IEC 581/03
Printed board temporary masking processes shall be carried out in accordance with the
requirements of IEC 61192-1.
Surface-mount component placement processes are described in IEC 61192-1 and shall be
carried out in accordance with the requirements stated therein.
The following visual attributes apply to the component placement process, using manual or
automatic inspection:
d) the orientation of components for example, pin 1 on ICs, polarity of electrolytic capacitors
and diodes;
e) the z axis condition of components for example, cant (non-parallelism), component on
edge;
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
The standard PPM baseline for surface-mounted component placement operations is the
number of placements attempted. Guideline assessment attributes and details of the method of
calculation are given in IEC 61193-1.
Discrete components with gull-wing leads are usually transistor or IC components, for example,
SOT 23. Components may be shifted in X or Y or rotation direction. The accept and reject
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target – Levels A, B, C
1 All lead feet, including heel regions and
toes, sit centrally on lands.
2 Component body not rotated.
IEC 582/03
Acceptable – Level A
1 All lead heels within the land.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
IEC 583/03
Nonconforming – Level A
1 Any lead heel overhangs land.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
IEC 584/03
IC components with flat-ribbon, L- or gull-wing leads on two sides are usually small outline
(SO) packages. Components may be shifted in X or Y or rotation direction. The accept and
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target – Levels A, B, C
1 All lead feet, including heel regions and
toes, sit centrally on lands.
2 Component body not rotated.
IEC 585/03
Acceptable – Level A
1 X-direction: no lead foot side overhang A
exceeds ½ W a or 0,5 mm, whichever is
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
less.
2 Y-direction: no lead toe overhang exceeds
½ W.
3 All lead heels within lands.
Acceptable – Level B
1 X-direction: no lead foot side overhang A
exceeds ½ W a or 0,5 mm, whichever is
less.
2 Y-direction: all lead toes and heels within
lands.
Acceptable – Level C
1 X-direction: no lead foot side overhang A
exceeds ¼ W or 0,5 mm, whichever is
less.
2 Y-direction: all lead toes and heels within
lands.
a ⅓ W when lead pitch is 0,5 mm or less.
W
IEC 586/03
Nonconforming – Level A
1 X-direction: any lead foot side overhang A
exceeds ½ W a or 0,5 mm, whichever is
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
less.
2 Y-direction: any lead toe overhang exceeds
½ W, or any lead heel overhanging land.
Nonconforming – Level B
1 X-direction: any lead foot side overhang A
exceeds ½ W a or 0,5 mm whichever is less.
2 Y-direction: any lead toe or heel over-
hanging land.
Nonconforming – Level C
1 X-direction: any lead foot side overhang A
exceeds ¼ W or 0,5 mm, whichever is less.
2 Y-direction: any lead toe or heel over-
hanging land.
NOTE When the land width P is narrower than
the component lead width W, the land edge
shall not protrude outside the lead edge in
Y-direction by more than ¼ P or 0,1 mm,
whichever is greater. See notes 1 and 2 in 9.1.
a ⅓ W when lead pitch is 0,5 mm or less.
P
A
Y
IEC 587/03
Components may be shifted in X or Y or rotation direction. The accept and reject criteria relate
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
to placement accuracy.
Target – Levels A, B, C
1 All lead feet, including heel regions and
toes, sit centrally on lands.
2 Component body not rotated.
IEC 588/03
Acceptable – Level A
1 X-direction: no lead foot side overhang A
exceeds ½ W a or 0,5 mm, whichever is
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
less.
2 Y-direction: no lead toe overhang exceeds
½ W.
3 All lead heels within lands.
Acceptable – Level B
1 X-direction: no lead foot side overhang A
exceeds ½ W a or 0,5 mm, whichever is
less.
2 Y-direction: no lead toes or heels overhang
lands.
Acceptable – Level C
1 X-direction: no lead foot side overhang A
exceeds ¼ W or 0,5 mm, whichever is
less.
2 Y-direction: all lead toes and heels within
lands.
a ⅓ W when lead pitch is 0,5 mm or less.
IEC 589/03
Nonconforming – Level A
1 X-direction: any lead foot side overhang A
exceeds ½ W a or 0,5 mm, whichever is
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
less.
2 Y-direction: lead toe overhang exceeds ½ W.
Nonconforming – Level B
1 X-direction: lead foot side overhang A
exceeds ½ W a or 0,5 mm, whichever is
less.
2 Y-direction: any lead toe or heel overhangs
land.
Nonconforming – Level C
1 X-direction: lead foot side overhang A
exceeds ¼ W or 0,5 mm, whichever is
less.
2 Y-direction: any lead toe or heel overhangs
land.
NOTE When the land width P is narrower than
the component lead width W, the land edge
shall not protrude outside the lead edge in
Y-direction by more than ¼ P or 0,1 mm,
whichever is greater. See notes 1 and 2 in 9.1.
a ⅓ W when lead pitch is 0,5 mm or less.
Y W
IEC 590/03
Components may be shifted in X or Y or rotation direction. The accept and reject criteria relate
to placement accuracy.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target – Levels A, B, C
1 All lead feet, including heel regions and
toes, sit centrally on lands.
2 Component body not rotated.
IEC 591/03
Acceptable – Levels A, B
1 X-direction: no lead side overhang A
exceeds ⅓ W.
W W 2 Y-direction: no lead toe overhang violates
minimum design clearance.
3 All lead heels within lands.
Acceptable – Level C
A Side A 1 X-direction: no lead side overhang A
exceeds ¼ W.
X 2 Y-direction: no lead toe overhang violates
the minimum design clearance.
3 All lead heels within lands.
Y
IEC 592/03
Nonconforming – Levels A, B
1 X-direction: any lead side overhang A
exceeds ⅓ W.
2 Y-direction: any lead toe overhang B
Toe violates minimum design clearance.
overhang 3 Any lead heel overhangs land.
Nonconforming – Level C
W 1 X-direction: any lead foot side overhang A
exceeds ¼ W.
B X
2 Y-direction: any toe overhang B violates
the minimum design clearance.
3 Any lead heel overhangs land.
Y
IEC 593/03
Components may be shifted in X or Y or rotation direction. The accept and reject criteria relate
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
to placement accuracy.
Target – Levels A, B, C
1 All lead feet, including heel regions and
toes, sit centrally on lands.
2 Component body not rotated.
Outer heel
of J-lead
IEC 594/03
Acceptable – Levels A, B
1 X-direction: no lead side overhang A
exceeds ½ W.
2 Y-direction: no lead outer heel overhang
exceeds W.
Acceptable – Level C
1 X-direction: no lead side overhang A
exceeds ¼ W.
2 Y-direction: no lead outer heel overhang
exceeds W.
W
A
Y
X
Outer heel
of J-lead
IEC 595/03
Nonconforming – Levels A, B
1 X-direction: any lead side overhang A
exceeds ½ W.
2 Y-direction: any lead heel overhang exceeds
W.
Nonconforming – Level C
1 X-direction: any lead foot side overhang A
exceeds ¼ W.
2 Y-direction: any lead heel overhang exceeds
W.
W
A
Y
X
Outer heel
of J-lead
IEC 596/03
Components may be shifted in X or Y or rotation direction. The accept and reject criteria relate
to placement accuracy.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target – Levels A, B, C
1 The component body sits centrally on lands
in both X and Y directions.
2 Body not rotated.
IEC 597/03
Acceptable – Level A
1 X-direction: no end overhang.
2 Termination/land overlap J is ⅔ T or more.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Y W
J
IEC 598/03
Nonconforming – Level A
1 X-direction: component body overhangs
land, or termination/land overlap J is less
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
than ⅔ T.
2 Y-direction: termination side overhang A is
greater than ½ W.
Nonconforming – Level B
1 X-direction: component body overhangs
land, or termination/land overlap J is less
than ⅔ T.
2 Y-direction: termination side overhang A is
greater than ⅓ W.
Nonconforming – Level C
1 X-direction: component body overhangs
land, or termination/land overlap J is less
than ¾ T.
2 Y-direction: termination side overhang A is
greater than ¼ W.
A
W
J
IEC 599/03
Components may be shifted in X or Y or rotation direction. The accept and reject criteria relate
to placement accuracy.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target – Levels A, B, C
1 The component body sits centrally on lands
in both X and Y directions.
2 Body not rotated.
IEC 600/03
Acceptable – Levels A, B
1 X-direction: no end overhang.
2 Termination/land overlap J is ⅔ T or more.
3 Y-direction: termination side overhang A
does not exceed ⅓ W.
Acceptable – Level C
1 X-direction: no end overhang.
2 Termination/land overlap J is T or more.
3 Y-direction: termination side overhang A
does not exceed ¼ W.
X
J
IEC 601/03
W Nonconforming – Levels A, B
1 X-direction: the component body over-
hangs land, or termination/land overlap J is
less than ⅔ T.
IEC 602/03
Components may be shifted in X or Y or rotation direction. The accept and reject criteria relate
to placement accuracy.
Target – Levels A, B, C
1 The component body sits centrally on lands
in both X and Y directions.
2 Component body not rotated.
J
P
IEC 603/03
Acceptable – Level A
1 X-direction: no end overhang.
2 Termination/land overlap J is ⅔ T or more.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Nonconforming – Level A
1 X-direction: the component body over-
hangs land, or termination/land overlap J is
less than ¾ T.
2 Y-direction: termination side overhang A is
greater than ½ W.
Nonconforming – Level B
1 X-direction: the component body over-
hangs land end, or termination/land
overlap J is less than ⅔ T.
2 Y-direction: termination side overhang A is
greater than ½ W.
Nonconforming – Level C
P 1 X-direction: the component body overhangs
Y land end, or termination/land overlap J is
W less than ⅔ T.
X
2 Y-direction: termination side overhangs
land.
IEC 605/03 NOTE When the land width P is narrower than
termination width W, the land edge shall not
protrude outside the termination edge in
Y-direction by more than ¼ P or 0,1 mm,
whichever is greater. See notes 1 and 2 in 9.1.
Components may be shifted in X or Y or rotation direction. The accept and reject criteria relate
to placement accuracy.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target – Levels A, B, C
1 The component body sits centrally on
lands in both X and Y directions.
2 Body not rotated.
C Land pattern
Castellated
termination
W A
Nonconforming – Levels A, B, C
1 X and Y directions: termination side over-
hang A exceeds ½ W.
2 The body outline overhangs the land out-
line in any direction.
Y
A
X
Components may be shifted in X or Y or rotation direction. The accept and reject criteria relate
to placement accuracy.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target – Levels A, B, C
1 All lead feet sit centrally on lands.
2 Component body not rotated.
IEC 609/03
Acceptable – Level A
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Y
B
X
A T
View A
IEC 610/03
Nonconforming – Levels A, B
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
W A
IEC 611/03
Components may be shifted in X or Y or rotation direction. The accept and reject criteria relate
to placement accuracy.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Y
X Target – Levels A, B, C
1 All lead feet, including heel regions and
toes, sit centrally on lands.
2 Component body not rotated.
IEC 612/03
P
W Acceptable – Levels A, B
A
1 X-direction: all heels within lands.
2 Y-direction: no lead side overhang exceeds
B ½ W.
Y Acceptable – Level C
IEC 613/03
IEC 614/03
Components may be shifted in X or Y or rotation direction. The accept and reject criteria relate
to placement accuracy.
Target – Levels A, B, C
Y
1 All lead feet, including heel regions and
toes, sit centrally on lands.
2 Component body not rotated.
IEC 615/03
Acceptable – Level A
J 1 X-direction: no lead toe overhangs land.
Y 2 Y-direction: no lead side overhangs land.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
W Acceptable – Level B
1 X-direction: no lead toe overhangs land.
X
Gap K is 2 T or less.
2 Y-direction: no lead side overhangs land.
Acceptable – Level C
T
1 X-direction: land protrusion B not less than T.
K Gap K not greater than T.
IEC 616/03
2 Y-direction: no lead side overhangs land.
Nonconforming – Level A
1 X-direction: any lead toe overhangs land.
J
Y 2 Y-direction: any lead side overhangs
land.
Nonconforming – Level B
W
1 X-direction: any lead toe overhangs land.
X
Gap K greater than 2 T.
2 Y-direction: any lead side overhangs
land.
T Nonconforming – Level C
K 1 X-direction: any lead toe overhangs land.
IEC 617/03
Gap K greater than T.
2 Y-direction: any lead side overhangs land.
10 Post-placement rework
Data on the performance of placement equipment should be based on process deviations and
defects recorded before any rework is applied.
For components that have been placed on the board away from their intended land pattern
position during the placement operation, their value and correct location should be checked
before replacing them manually with new ones. Damaged components should not be used for
checking purposes.
Page 47
EN 61192−2:2003
61192-2 IEC:2003 – 47 –
Pre-reflow rework should be carried out while the paste or adhesive surface retains its
tackiness.
Non-metallic conductive tweezers should be used for all post-placement rework involving
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Where there is general misplacement of all components in the same direction, action must be
taken to correct placement error. The coplanarity of multi-lead fine pitch component leads
requires careful checking.
Provided the component body is in contact with the adhesive, correction of minor surface
mount component placement errors by careful movement of the body is acceptable. Horizontal
movement can be applied without any lifting action. Should the component accidentally be
parted from the adhesive mound, a small amount of additional adhesive should be applied
to the underside of the component before replacing it. Care must be taken to avoid smudging
the adhesive onto nearby test points, vacant lands or components.
11 Adhesive curing
The time-temperature profile used for curing should comply with the adhesive manufacturer’s
recommendations.
The following attributes can apply to the adhesive curing process, using manual or automatic
inspection:
12 Soldering processes
Soldering processes are described in IEC 61192-1 and shall be carried out in accordance with
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
The following attributes apply to the component soldering processes, using manual or auto-
matic visual inspection to meet requirements defined in Figure 1 through Figure 44:
Other attributes applying to the component soldering processes that are not normally exposed
by post-soldering visual inspection or electrical test are:
The standard PPM baseline for surface-mounted component soldering operations is the
number of solder joints attempted. Guideline assessment attributes and details of the method
of calculation of PPM values are given in IEC 61193-1.
13 Cleaning processes
The following attributes can apply to the post-soldering cleaning processes, using manual or
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
The standard PPM baseline for surface-mounted component soldering operations is twice the
printed board size in cm 2 . Guideline assessment attributes and details of the method of
calculation of PPM values are given in IEC 61193-1.
Rework requirements are given in IEC 61192-1, Clause 18 and shall be carried out in
accordance with the relevant paragraphs therein.
The immediate post-operation assessment of rework and repair processes in production can
be performed in several ways, for example, by manual or automatic visual inspection, laser
scan, measuring the thermal properties of the joint, X-ray.
The attributes that can apply to the rework soldering processes, using manual or automatic
visual inspection and electrical test are given in Clause 12 above.
The standard PPM baseline for surface-mounted component manual or rework soldering
operations is the number of solder joints soldered. Guideline assessment attributes and details
of the method of calculation of PPM values are given in IEC 61193-1.
Minimum acceptance criteria for post-soldering component alignment and solder joints on
assembled boards are given in IEC 61191-2.
15 Electrical test
The recommended workmanship procedures are given in IEC 61191-1. Care should be taken
to ensure that the testing does not itself cause harm to the assembly, either through
mechanical damage (for example, arising from deformation of the printed board under pressure
from probe systems) or from electrical overstress.
Page 50
EN 61192−2:2003
61192-2 IEC:2003 – 50 –
Annex A
(normative)
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
A.1 Introduction
This annex contains illustrated examples of ‘target’ and ‘acceptable’ conditions for alignment
between surface-mounted components and their related land patterns and for the solder joint
fillets on their leads and terminations. They are intended solely to assist interpretation of the
post-soldering inspection requirements given in IEC 61191-2.
The following pictures and diagrams do not represent all potential process deviations and do
not show any examples of defects.
A.2 Example solder fillets and alignment: flat-ribbon, L- and gull-wing leads
The examples furnished are to assist in interpreting the requirements of IEC 61191-2, Figure 3.
NOTE The cut end of the toe need not be wetted.
Target: height of concave fillets a at lead edges equal Target: all component lead feet, including heel regions
to lead thickness T along entire length L. and toes, sit central relative to land width and length.
Heel region filled to a height of G + T. Land completely
wetted.
a Solder fillets along lead foot edges are not required
on the overhung edge, or where the lead width is
equal to or greater than the land width, or when
lead edges are cropped from sheet metal.
T
L
Optimal joint
Meniscus not
required
G
IEC 619/03
IEC 618/03
Acceptable: wetting of both lead side edges a evident Acceptable: lead foot side overhang A is less than ½ W b .
along more than ½ L. Fillet height at heel is greater No toe overhang. Heel region is within land.
than G + ⅔ T. b ⅓ lead width when lead pitch is less than 0,5 mm.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
T Minimum joint
Meniscus not
required
G
Examples furnished are to assist in interpreting the requirements of IEC 61191-2, Figure 4.
Target: height of concave fillets a at lead edges equal Target: all component lead feet, including heel regions
to lead thickness T along entire length L. and toes, sit central relative to land width and length.
Heel region filled to a height of G + T.
W
Land completely wetted.
W
a Solder fillets along lead foot edges are not required
on the overhung edge, nor where the lead width is
equal to or greater than the land width.
C C
D D
IEC 622/03 IEC 623/03
Acceptable: wetting of both lead side edges a evident Acceptable: lead foot side overhang A in side direction
along more then ⅔ L. Fillet height at heel is greater and toe overhang B in length direction are both less
than G + ½ T or 0,5 mm whichever is less. than ⅓ W b . Heel region is within land.
a Solder fillets along lead foot edges are not required b ⅓ lead width when the lead pitch is less than 0,5 mm.
on the overhung edge, nor where the lead width is
equal to or greater than the land width.
G
G
Q Q
G G
G
G
IEC 624/03
IEC 625/03
Examples furnished are to assist in interpreting the requirements of IEC 61191-2, Figure 5.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target: inner and outer heel fillets soldered to start of Target: all component lead feet, including heel regions
lower J-lead radius. Side fillets on J-lead are at lead and toes, sit central relative to land width and length.
thickness T. No solder touching component body. Land
completely wetted.
Optimal joint
IEC 627/03
IEC 626/03
Acceptable: inner and outer heel fillet heights greater Acceptable: lead foot side overhang A is less than
than G + ½ T. ½ W b . No toe overhang. Heel region is within land.
a Solder fillets along lead foot edges are not required b ⅓ lead width when lead pitch is less than 0,5 mm.
on the overhung edge, or where the lead width is
equal to or greater than the land width, or when lead
edges are cropped from sheet metal.
A IEC 629/03
IEC 628/03
Examples furnished are to assist in interpreting the requirements of IEC 61191-2, Figure 6.
Target: concave end face fillet has height G + ¾ H, is Target: component body sits centrally on lands in both
wetted to entire width of end face surface and extends length and width directions. Termination side face
outward on land ¾ W beyond termination. Side fillet completely on land.
heights at ½ H minimum over entire length T. Land
completely wetted.
D
C
IEC 630/03
P
IEC 631/03
Acceptable: end-face fillet height is greater than G + ¼ H Acceptable: side overhang A is less than ⅓ W a .
or G + 0,5 mm, whichever is greater. Side fillet height is Component body overlaps land by more than ⅔ T b .
greater than ½ T. End joint width C is greater than ½ W. No end overhang of termination beyond land.
No solder on body beyond termination. a Or 1,5 mm, whichever is less.
b Not applicable to 1-face (end-face only) termi-
nations.
E H
G
G
IEC 632/03
IEC 633/03
A.6 Example solder fillets and alignment: cylindrical end cap terminations,
for example, MELFs
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Examples furnished are to assist in interpreting the requirements of IEC 61191-2, Figure 7.
Target: concave end-face fillet has height W, is wetted Target: component body sits centrally on lands in both
to entire width of end face-surface and extends outward length and width directions. Termination side face
on land ¾ W beyond termination end face. Side fillet completely on land.
heights at ½ W minimum over entire length T. Land
completely wetted.
W
T
C
P
P D
Solder
T ¾W
Device
IEC 635/03
IEC 634/03
Acceptable: end-face fillet height is greater than G + ¼ H Acceptable: side overhang A is less than ⅓ W.
or G + 0,5 mm, whichever is greater. Side fillet height is Component body overlaps land by more than ⅔ T.
greater than ½ T. End joint width C is greater than ½ W. No end overhang of termination beyond land.
No solder on body beyond termination.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
T
W
A
¼G
IEC 637/03
IEC 636/03
Examples furnished are to assist in interpreting the requirements of IEC 61191-2, Figure 8.
Target: solder wetting to underside of component and Target: termination areas on underside of component
land at each end is evident as a continuous joint along sit centrally within lands in both length and width
all three visible edges. All visible parts of land wetted. directions.
F
G
IEC 639/03
IEC 638/03
Acceptable: end joint width exceeds ½ W. Acceptable: no end overhang. Side overhang is less
than ⅓ W.
W
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
C
P
A
C
A.8 Example solder fillets and alignment: leadless chip carriers with
castellated terminations
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Examples furnished are to assist in interpreting the requirements of IEC 61191-2, Figure 9.
Target: concave fillets on all castellations. Fillet Target: all castellations sit centrally on lands. All land
heights are G + H and cover full width of each land and projections outside component body are equal and not
castellation. Visible evidence of wetting to all termi- less than ¾ H.
nation areas beneath component body. Land areas
outside body completely wetted. D
Acceptable: end joint width C is greater than ½ W. Acceptable: castellation side overhang from land A is
Fillet height F is greater than G + ¼ H. less than ½ W. No end overhang of component body
outline beyond any land.
Side joint length D is greater than ½ F.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
W C
A A
IEC 645/03
IEC 644/03
Examples furnished are to assist in interpreting the requirements of IEC 61191-2, Figure 10.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target: fillet height 2,5 W. Land completely wetted. Target: lead toes, sit central within each land. Land
protrusion B outside each toe end face is 2 W.
W
Lead
Land
F
IEC 647/03
C
IEC 646/03
Acceptable: fillet heights greater than G + 0,5 mm. Acceptable: no side overhang outside land. Land
End joint width greater than ¾ W. Solder thickness protrusion B outside each toe face (except end face) is
under toe is less than 0,1 mm. greater than lead thickness T.
IEC 649/03
D
IEC 648/03
A.10 Example solder fillets and alignment: inward L-shaped flat ribbon leads
Examples furnished are to assist in interpreting the requirements of IEC 61191-2, Figure 11.
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Target: height of concave fillet at lead end face is G + ¾ H Target: component lead feet, including heel regions
along entire lead width W. Signs of wetting between and toes, sit central relative to land width and length.
underside of foot and land along entire length of inward L
lead sides a. Visible parts of land completely wetted.
a Or 0,5 mm, whichever is greater.
L H
IEC 650/03
IEC 651/03
Acceptable: end-face fillet height greater than G + ¼ H a Acceptable: lead foot side overhang A is less than ½ W.
across more than ½ lead width W. Joint to land extends
outward beyond lead end face by more than ½ H b.
a Or 0,5 mm, whichever is greater.
b Or 0,5 mm, whichever is less.
L
G
½ L ou 0,5 mm
IEC 652/03
IEC 653/03
Examples furnished are to assist in interpreting the requirements of IEC 61191-2, Figure 12.
Target: side joint length extends over entire length of Target: lead completely on land so that land projects
lead/land interface. End joint width is equal to lead outside lead sides and toe end by lead thickness T.
width W. Fillets at lead sides and at toe end are at full Dimension K is less than lead thickness.
lead thickness. G is less than 0,1 mm. Visible land
areas are completely wetted.
IEC 654/03
IEC 655/03
Acceptable: end joint width greater than ½ W. Side joint Acceptable: no side or toe overhang. K is less than T.
length not less than L – K.
IEC 656/03
IEC 657/03
___________
Page 64
EN 61192−2:2003
Annex ZA
(normative)
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of any
of these publications apply to this European Standard only when incorporated in it by amendment or
revision. For undated references the latest edition of the publication referred to applies (including
amendments).
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
1)
Undated reference.
2)
Valid edition at date of issuie.
Page 65
EN 61192−2:2003
1) 2)
ISO 9002 - Quality systems - Model for quality EN ISO 9002 1994
assurance in production, installation and
servicing
BS EN
61192-2:2003
BSI — British Standards Institution
BSI is the independent national body responsible for preparing
British Standards. It presents the UK view on standards in Europe and at the
international level. It is incorporated by Royal Charter.
Revisions
Licensed Copy: x x, Hampshire Libraries, Thu Apr 19 09:19:13 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Buying standards
Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: +44 (0)20 8996 9001.
Fax: +44 (0)20 8996 7001. Email: [email protected]. Standards are also
available from the BSI website at http://www.bsi-global.com.
In response to orders for international standards, it is BSI policy to supply the
BSI implementation of those that have been published as British Standards,
unless otherwise requested.
Information on standards
BSI provides a wide range of information on national, European and
international standards through its Library and its Technical Help to Exporters
Service. Various BSI electronic information services are also available which give
details on all its products and services. Contact the Information Centre.
Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email: [email protected].
Subscribing members of BSI are kept up to date with standards developments
and receive substantial discounts on the purchase price of standards. For details
of these and other benefits contact Membership Administration.
Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001.
Email: [email protected].
Information regarding online access to British Standards via British Standards
Online can be found at http://www.bsi-global.com/bsonline.
Further information about BSI is available on the BSI website at
http://www.bsi-global.com.
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may be
reproduced, stored in a retrieval system or transmitted in any form or by any
means – electronic, photocopying, recording or otherwise – without prior written
permission from BSI.
This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
BSI written permission of BSI must be obtained.
389 Chiswick High Road Details and advice can be obtained from the Copyright & Licensing Manager.
London Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553.
Email: [email protected].
W4 4AL