FSD Biome Sample
FSD Biome Sample
FSD Biome Sample
1
TABLE OF CONTENTS
Acronyms and Abbreviations.................................................................................................................... 3
2
Acronyms and Abbreviations
3
Document Information
Prepared By: Tooba Mirza
Issue Date: 05th September, 2019
Reviewed By: Farhan Munir
Approved By: Imran Moinuddin, Collin Stoner
Approval Date: 18th September, 2019
Status: Draft
Revision History
Revision Date Author(s) Description
Number
V1.0 05th Sep, 2019 Tooba Mirza -
4
Purpose & Overview
Biome produces indoor green walls that purify the air and beautify the architectural space. The
machines are self-sufficient, hydroponic plant gardens that host between 10 and 40 plants, an
internal water tank and the proper air and plumbing to keep the plants alive and healthy as they
scrub the air.
To support the device, an onboard controller manages the water and air cycles with a suite of
sensors to detect and adapt to the surrounding environment. Based on the needs of the plants,
more or less light, water and air are applied to the plants.
To track performance and add value to the user, the devices are WiFi enabled and transmit sensor
and health data back to a server where the data can be monitored to improve functionality and
maintain the plants (which are very sensitive to environmental changes
Current Implementation
The current server is implemented in Node.js running on a low tier AWS virtual machine. Time series
data is stored using Influx DB and control/management data is stored in a MongoDB server, hosted
by MongoDB as a service.
The current implementation is scale limited and has nearly reached capacity. Additionally, it lacks
a front end that can be shown to customers. Data is plotted with Grafana for engineering use only.
Once the new scalable system is in place, existing implementation will no longer be applicable.
Desired Implementation
The product of the IOT application development is a Serverless design implemented on AWS, to
allow seamless scale out and an attractive front end for customers to interact with in addition to
the engineering and plant operations team.
From the backend, a standard Serverless architecture:
5
o DynamoDB or MongoDB should be used to track all data
o Lambda functions and API Gateways should be used to manage data intake, ideally
implemented in JavaScript
o Cognito should provide authentication for users and super-users (plant operations and
engineering)
o AWS Amplify and S3 would be used to store, build, deploy, and host web application on AWS
React.js JavaScript library will be used to develop application front end.
A front-end sketch has been provided to be used as a base to build the front end. A front-end
HTTP and CSS template has been provided to minimize coding of the front-end look and feel
Type POST
Takes in sensor and health data on regular intervals from each machine
Data:
Field Detail
Pump_dry A flag indicating if the pump has detected no water and must be primed by
filling the tank
6
Command API
Type GET
Requests the top queued command for the device. Commands are issued onto a FIFO stack. The
top command will remain active until it is confirmed (which pops it off the top of the stack). Until
confirmation, the same command will be returned by this api call.
This call will be made repeatedly by the device on 10-15 second intervals. If a command is
supplied, it will be executed and validated if successfully received. (Execution does not need to
be successful, only receipt). Another GET may be issued rapidly after the previous command is
executed to speedily execute multiple commands.
Data:
Field Detail
Uuid A UUID that may be used to validate and complete the command later
Type POST
Indicates that the device received and executed a command. The command may now be
removed from the queue.
Data:
Field Detail
Result The result of the command (string). Success/failure/string data for result, etc…
Commands are provided in the ‘cmd’ field of the command GET function call. The command
indicates the type of operation the device should take. The Data field is used by the device to
complete the operation. Both are strings.
The commands, their functions and associated data are detailed below:
OTA Relative URL of OTA Device should start an Over-The-Air firmware update. The
package (for data string is the URL of the OTA firmware file, relative to the
7
example: server base address. The OTA firmware file must be publicly
/version22.firmware) accessible so that the device may download it.
LED {r: <0-255>, g: <0- Sets the color of the LED’s and which LEDs are enabled. R,
255>, b: <0-255>, g, and b are the Red, Green and Blue color values. Left,
left: true/false, right: right, top, bottom are Booleans that indicate if the LED bank
true/false, top: should be displayed or not.
true/false, bottom:
true/false
WATER JSON array of 24 Updates the water target numbers on the device. There is
numbers, 0-100. one setting for each hour of the day (24 numbers total).
Each setting is between 0 and 100.
Out of Scope
Any requirement or clause that is not part of this document will be considered out of scope
Any requirement that has not been made part of Signed off Functional Specification / Scope
document would require Change Management process to initiate, if the effort per requirement
is 5 working hours or more. This change would also demand a respective change in project’s
Scope, Cost and Schedule
8
User Stories:
User Story 1: Sign In
User Interface
9
Key Functional Points:
In case of unsuccessful Login, user may be redirected to Forget Password screen to reset the
password for a respective account
User Account with that email address must exist in the system
For this system to be operational, the metric to determine air pressure are temperature, humidity,
lighting and water level. Air Quality and Comfort Level are not being considered for now
The top left level chart on Dashboard displays the average of all devices for a respective
Company for each metric at a specified time (last 12 hours)
The top right stats is the average of all devices in the system for a specific metric at the current
time
The lower table represents the location wise average of devices of a respective Company in
the system for each metric at the current time
Appropriate symbols will be used to represent metrics
10
Key Functional Points:
Graphical representation of location wise average of all devices of a respective Company for
each metric (temperature, humidity, lighting and water level ) at the current time
11
Key Functional Points:
Chart wise representation of the average of all devices of a respective location for last 12 hours
for each metric (temperature, humidity, lighting and water level)
This functionality has check boxes to turn on / off a metric wave and date time filters as well
The stats on top is the average of all devices in the system for each metric at the current time
for that location
This feature show the current water level of all devices present in the system at every location
Taiga is a name given to IOT devices
12
Key Functional Points:
This feature shows the lighting arrangement at four sides of each device/Taiga
Lights can also be controlled from here e.g. if we uncheck “Left” of Device 01 from the lighting
panel in the system, the left light of device would turn off.
13
Key Functional Points:
Personas:
o Super User can access and alter all functionalities in the system.
o Admin users can access and alter those functionalities that belong to the Company he/she
is made part of.
o Non-Admin can only access those screens they have been given permission of
Super User can add / activate / deactivate companies in the system
Super User / Admin can add / activate / deactivate users in the system. There will be no hard
delete in the system
A user can belong to only one Company in the system
There will be an admin web panel / command line interface to send a firmware update
command, reset command to a device and machine settings update (send new water target,
send new fan settings, etc.)
Note: Commands will always be generated by some triggering mechanism like on/off light
switches, reset of devices etc. There will be no scheduled mechanism to deal with commands.
Super User / Admin can add / activate / deactivate locations and devices in the system of their
respective companies. There will be no hard delete in the system
Super User / Admin can assign devices to specific locations
A company can have one or many locations. A location can have one or many devices
If a company is deactivated, all locations, users and devices associated with it will automatically
be deactivated in the system. If a location is deactivated, all devices connected to that
location will automatically be deactivated in the system
15
User Story 11: Email Notification Mechanism
User Interface
User would get notified if water level of a device reaches a certain level below threshold as
shown in the above wireframe
For this system, any other threshold settings except water level is not required to maintain