1. The electrical installation shown in the plans must conform to the latest Philippine Electric Code and regulations of the local electric company and government. 2. All electrical materials must be brand new, approved, and of good quality. 3. All wiring must be installed in standard electrical PVC conduit pipes embedded inside hollow blocks, concrete structures, slabs, columns, walls, and partitions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views1 page

FFFF

1. The electrical installation shown in the plans must conform to the latest Philippine Electric Code and regulations of the local electric company and government. 2. All electrical materials must be brand new, approved, and of good quality. 3. All wiring must be installed in standard electrical PVC conduit pipes embedded inside hollow blocks, concrete structures, slabs, columns, walls, and partitions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CHURCH

PROJECT SITE GENERAL NOTES AND SPECIFICATIONS


TO 1. THE ELECTRICAL INSTALLATION SHOWN ON THE PLANS SHALL CONFORM
LIG LOT 50-B, PAULATE STREET, GUINOBATAN, ALBAY.
ACU A WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRIC CODE RULES
PLAZA O
AND REGULATIONS OF THE LOCAL ELECTRIC COMPANY AND THE LOCAL
17 GOVERNMENT WHERE THE PROJECT WILL BE CONSTRUCTED.
BEDROOM 2 2. ALL ELECTRICAL MATERIALS AND EQUIPMENT TO BE USED IN THIS
PROJECT SHALL BE BRAND NEW AND OF APPROVED QUALITY AND BRAND.
WATT HOUR

T
METER 3. ALL WIRING SHALL BE INSTALLED IN STANDARD ELECTRICAL uPVC

E
RE
CONDUIT PIPES RUN EMBEDDED INSIDE THE HOLLOW BLOCKS

ST
BEDROOM S4 S S PRIVATE AND CONCRETE STRUCTURES SLABS COLUMNS WALLS PARTITIONS AND

E
AT
CONCRETE OR RUN CONCEALED BETWEEN DOUBLE WALL WOODEN PARTITIONS AND

UL
WH
S 19

PA
POST INSIDE THE CEILING SPACES WHERE THE USE IF CONCEALED OR EMBEDDED
COMMON NA CONDUIT WIRING IS IMPRACTICABLE METAL MOULDING WIRING MAYBE USED.
COMMON CR CR TI 4. UNLESS OTHERWISE INDICATED ON THE PLANS THE MINIMUM SIZE OF THE CONDUIT
ON
WH AL AND WIRE TO BE USED SHALL BE 20MMØ SCHED 40 AND 3.5MM² TW 600V INSULATION.
20
HI 5. WHEREVER REQUIRED AND NECESSARY PULL BOXES AND JUNCTION BOXES
HALLWAY 1.20m WIDE

HALLWAY 1.10m WIDE


T&B GH
2 W OF PROPER SIZES SHALL BE INSTALLED AT A CONVENIENT AND INCONSPICUOUS
T&B WP WM AY LOCATIONS ALTHOUGH SUCH BOXES ARE NOT SHOWN ON THE PLANS NOR
S 4
26 25 TO MENTIONED ON THE SPECIFICATIONS.
MARKET LEG
S S AZP
LPP LPP
I 6. THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE SINGLE PHASE 220V AC
WALK 7. MOUNTING HEIGHT OF ELECTRICAL DEVICES SHALL BE AS FOLLOWS
WALK IN

AD
3 5
IN

RO
CLOSET 23 A. WALL SWITCHES 1.37M ABOVE FINISH FLOOR LEVEL
CLOSET

AR
B. CONVENIENCE OUTLETS 0.30M ABOVE FINISH FLOOR LEVEL

LL
R PUBLIC

VE
C. AIRCONDITIONING OUTLETS 2.00M ABOVE FINISH FLOOR LEVEL

JO
24 SCHOOL D. PANEL BOARD 1.37M ABOVE FINISH FLOOR LEVEL

AN
11
KITCHEN 18 KITCHEN
S S S S ACU E. WASHING MACHINE OUTLET 1.50M ABOVE FINISH FLOOR LEVEL

AT
REF

OB
MASTER F. KILOWATT HOUR METER 1.85M FROM GROUND TO CENTER OF METER

IN
GU
BEDROOM 9 9 8. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE
8
S 8 SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER OR MASTER ELECTRICIAN
7
MASTER 7
BEDROOM
6
5
2 CAR
6
5
2 CAR 7 VICINITY MAP
GARAGE GARAGE NOT DRAWN TO SCALE
4
3
4
3
DINING E1
2 2
1 10 1
MATV T

1
DINING
TTC WP
LINE SIDE LOAD SIDE
LEGEND ELECTRICAL SYMBOLS
PROPERTY LINE TUBULAR OR COMPACT FLOURESCENT LIGHT
FOYER PINLIGHT WITH COMPACT FLOURESCENT BULB
WALL BRACKET LAMP WITH COMPACT FLOURESCENT BULB
FOYER
SERVICE DROP DUPLEX CONVENIENCE OUTLET
LIVING ROOM
WP WEATHER PROOF DUPLEX CONVENIENCE OUTLET
ENTRANCE CAP REF REFRIGERATOR OUTLET
S S S S S S S
R THREE PRONG COOKING RANGE OUTLET
DRIP LOOP WIRES ACU AIRCONDITIONING OUTLET
LIVING ROOM 3 CIRCUIT HOMERUN FOR LIGHTING
CONDUIT STRAPPED TO LIGHTING AND POWER 3 CIRCUIT HOMERUN FOR APPLIANCE OUTLETS
2 2 CONCRETE POST PANEL BOARD S FLUSH TYPE WALL SWITCH
1 1 WH WATER HEATER OUTLET

5500
WM WASHING MACHINE WITH DRYER OUTLET
LPP LIGHTING AND POWER PANELBOARD
WATT HOUR METER GROUNDING WIRE BELL BUZZER WITH 220V-12V/6V/3V TRANSFORMER
DOOR BELL PUSH BUTTON
ENTRANCE ELL T TV CABLE OUTLET
MATV MASTER ANTENNA TV CABLE OUTLET
TTC TELEPHONE TERMINAL CABINET
PUBLIC ROAD TELEPHONE OUTLET
TELEPHONE EXTENSION / NTERCOMMUNICATION

1 GROUND FLOOR LIGHTING LAYOUT 3 GROUND FLOOR POWER LAYOUT 6 SERVICE DROP INSTALLATION
E1 SCALE 1:100 E1 SCALE 1:100 E1 SCALE 1:100

ACU
14
NORMAL MANUAL
SCHEDULE OF LOADS
BEDROOM 4 SERVICE TRANSFER NO OF NO OF OTHER VA PER AMP SIZE OF BRKS SIZE OF HOMERUN
6
SWITCH CRT NO. LOAD DESCRIPTION
M LIGHTS C.O. LOAD CIRCUIT LOAD/CRT F P T WIRE CONDUIT
BEDROOM 4 S 1 40W LED LAMP 9 360 1.63 50 2 20 2-3.5mm² THHN 20mmØ PVC
WH 2 2 2 40W LED LAMP 8 320 1.45 50 2 20 2-3.5mm² THHN 20mmØ PVC
S 21 2-60mm THHN + 1-14mm THHN (G)
150AT
in 65 mmØ PVC 3 40W LED LAMP 9 360 1.63 50 2 20 2-3.5mm² THHN 20mmØ PVC
COMMON CR
COMMON G
CR 4 40W LED LAMP 12 480 2.18 50 2 20 2-3.5mm² THHN 20mmØ PVC
7
WH GEN SET
22
5 40W LED LAMP 10 400 1.18 50 2 20 2-3.5mm² THHN 20mmØ PVC
HALLWAY 1.20m WIDE

HALLWAY 1.10m WIDE

T&B 150AT
T&B
6 40W LED LAMP 10 400 1.18 50 2 20 2-3.5mm² THHN 20mmØ PVC
S 9 1 20A 20A 2 7 40W LED LAMP 7 280 1.27 50 2 20 2-3.5mm² THHN 20mmØ PVC
S S S 16 ACU
LPP 8 40W LED LAMP 8 320 1.45 50 2 20 2-3.5mm² THHN 20mmØ PVC
WALK 3 20A 20A 4
WALK IN 9 40W LED LAMP 9 360 1.63 50 2 20 2-3.5mm² THHN 20mmØ PVC
IN
CLOSET L S L
15 S CLOSET 15 5 20A 20A 6 10 DUPLEX CONVENIENT OUTLET 10 1,800 8.18 50 2 20 3-3.5mm² THHN 20mmØ PVC
LOUNGE 8
14 S 14
13 13
LOUNGE BEDROOM 5 11 DUPLEX CONVENIENT OUTLET 8 1,440 6.54 50 2 20 3-3.5mm² THHN 20mmØ PVC
12 7 20A 20A 8
15
S S S S 12
ACU 12
12 DUPLEX CONVENIENT OUTLET 8 1,440 6.54 50 2 20 3-3.5mm² THHN 20mmØ PVC
11 11
BEDROOM 3 1,440
10 10
9 20A 20A 10 13 DUPLEX CONVENIENT OUTLET 8 6.54 50 2 20 3-3.5mm² THHN 20mmØ PVC
9 9
8
L
BEDROOM 5 8
L
14 AIRCON 1 1,760 8.00 50 2 20 3-3.5mm² THHN 20mmØ PVC
1 1
7 BEDROOM 3 7
6
2
6
2 11 20A 20A 12 15 AIRCON 1 1,760 8.00 50 2 20 3-3.5mm² THHN 20mmØ PVC
3 3
5
L
5
L 16 AIRCON 1 1,760 8.00 50 2 20 3-3.5mm² THHN 20mmØ PVC
4 4 13 20A 20A 14
3 3 17 AIRCON 1 1,760 8.00 50 2 20 3-3.5mm² THHN 20mmØ PVC
2 2
S S S 13 15 20A 20A 16 18 AIRCON 1 1,760 8.00 50 2 20 3-3.5mm² THHN 20mmØ PVC
WP WP 3,000
19 WATER HEATER 1 13.63 50 2 20 3-3.5mm² THHN 20mmØ PVC
17 20A 20A 18
20 WATER HEATER 1 3,000 13.63 50 2 20 3-3.5mm² THHN 20mmØ PVC
19 20A 20A 20 21 WATER HEATER 1 3,000 13.63 50 2 20 3-3.5mm² THHN 20mmØ PVC
22 WATER HEATER 1 3,000 13.63 50 2 20 3-3.5mm² THHN 20mmØ PVC
TERRACE DECK TERRACE DECK 21 20A 20A 22 23 RANGE 1 3,000 13.63 50 2 30 2-5.5mm² THHN 25mmØ PVC
1-5.5mm² THHN
23 30A 20A 24
24 REFRIGERATOR OUTLET 1 250 1.13 50 2 20 3-3.5mm² THHN
20mmØ PVC
25 20A 20A 26 25 WASHING MACHINE 1 1,200 5.45 50 2 20 3-3.5mm² THHN
20mmØ PVC
WP WP 26 WATER PUMP 1 1,760 8.00 50 2 20 3-3.5mm² THHN
20mmØ PVC
27 28
27 SPARE 1 1,500 6.82 50 2
28 SPARE 1 1,500 6.82 50 2
SECOND FLOOR LIGHTING LAYOUT SECOND FLOOR POWER LAYOUT SINGLE LINE DIAGRAM TOTAL LOAD OF THE BUILDING 39,410 179.14 AMPERES
2 4 5 USE 150 AT, 250AF 220V CIRCUIT BREAKER
E1 SCALE 1:100 E1 SCALE 1:100 E1 SCALE NDTS D.F. ( DEMAND FACTOR ) = 75% I T =179.14 x 0.75 = 134.35 AMPERES
2-60mm2 THHN + 1-14mm2 THHN (G)
in 65 mmØ PVC

SHEET CONTENTS SHEET NO.

LIGHTING LAYOUT 1
POWER LAYOUT E1 1
SINGLE LINE DIAGRAM 10 10
SCHEDULE OF LOADS
DESIGN ANALYSIS ELECTRICAL

You might also like