Data sheet 6ES7410-5HX08-0AB0

SIMATIC PCS 7, CPU 410-5H Process Automation, central processing unit for S7-
400 and S7-400H/F/FH, 5 interfaces: 2x PN, 1x DP, 2x for sync modules for using
as spare part, without System Expansion Card

General information
Product type designation CPU 410-5H
HW functional status 2
Firmware version V8.2
Design of PLC basic unit With Conformal Coating (ISA-S71.04 severity level G1; G2; G3) and operating
temperature to 70 °C
Product function
● SysLog Yes; via TCP; up to 4 receivers can be parameterized; buffer capacity max. 3
200 entries
● Field interface security Yes
Engineering with
● Programming package SIMATIC PCS 7 V9.0 or higher
CiR - Configuration in RUN
CiR synchronization time, basic load 60 ms
CiR synchronization time, time per I/O byte 0 µs
Input current
from backplane bus 5 V DC, typ. 2A
from backplane bus 5 V DC, max. 2.4 A
from backplane bus 24 V DC, max. 150 mA; DP interface
from interface 5 V DC, max. 90 mA; At the DP interface
Power loss
Power loss, typ. 10 W
Processor
CPU speed 450 MHz; Multi-processor system
Memory
PCS 7 process objects 100 ... approx. 2 600, adjustable with System Expansion Card
Work memory
● integrated 32 Mbyte; max., dependent on the System Expansion Card used
● integrated (for program) Dependent on the System Expansion Card used
● integrated (for data) Dependent on the System Expansion Card used
● expandable Dependent on the System Expansion Card used
Load memory
● integrated RAM, max. 48 Mbyte
● expandable RAM No
Backup
● with battery Yes; all data
● without battery Yes; Program and data of the load memory
Battery
Backup battery
● Backup current, typ. 370 µA; Valid up to 40°C

6ES74105HX080AB0 Subject to change without notice


2/15/2024
Page 1/8 © Copyright Siemens
● Backup current, max. 2.1 mA
● Backup time, max. Dealt with in the module data manual with the secondary conditions and the
factors of influence
● Feeding of external backup voltage to CPU No
CPU processing times
for bit operations, typ. 7.5 ns
for word operations, typ. 7.5 ns
for fixed point arithmetic, typ. 7.5 ns
for floating point arithmetic, typ. 15 ns
average processing time of PCS 7 typicals 110 µs; with APL Typicals
Process tasks, max. 9; Individually adjustable from 10 ms to 5 s
CPU-blocks
DB
● Number, max. 16 000; Number range: 1 to 16 000 (= Instances)
● Size, max. 64 kbyte; Dependent on the System Expansion Card used
FB
● Number, max. 8 000; Number range: 0 to 7999
● Size, max. 64 kbyte
FC
● Number, max. 8 000; Number range: 0 to 7999
● Size, max. 64 kbyte
OB
● Number, max. see instruction list
● Size, max. 64 kbyte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 8; OB 10-17
● Number of delay alarm OBs 4; OB 20-23
● Number of cyclic interrupt OBs 9; OB 30-38 (= Process Tasks)
● Number of process alarm OBs 8; OB 40-47
● Number of DPV1 alarm OBs 3; OB 55-57
● Number of startup OBs 2; OB 100, 102
● Number of asynchronous error OBs 9; OB 80-88
● Number of synchronous error OBs 2; OB 121, 122
Nesting depth
● per priority class 24
● additional within an error OB 2
Counters, timers and their retentivity
IEC counter
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
IEC timer
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. Total working and load memory (with backup battery)
Flag
● Size, max. 16 384 byte
● Retentivity available Yes
● Number of clock memories 8; in 1 memory byte
Local data
● adjustable, max. 64 kbyte
Address area
I/O address area
● Inputs 16 kbyte; max., dependent on the System Expansion Card used
● Outputs 16 kbyte; max., dependent on the System Expansion Card used
Process image
● Inputs, default 16 kbyte; not changeable
● Outputs, default 16 kbyte; not changeable
● consistent data, max. 244 byte

6ES74105HX080AB0 Subject to change without notice


2/15/2024
Page 2/8 © Copyright Siemens
● Access to consistent data in process image Yes
Subprocess images
● Number of subprocess images, max. 15
Hardware configuration
Number of expansion units, max. 21; S7-400 expansion devices
connectable OPs 119
Multicomputing No
Interface modules
● Number of connectable IMs (total), max. 6
● Number of connectable IM 460s, max. 6
● Number of connectable IM 463s, max. 4; Single mode only
Number of DP masters
● integrated 1
● via CP 10; CP 443-5 Extended
Number of IO Controllers
● integrated 2
● via CP 0
Number of operable FMs and CPs (recommended)
● PROFIBUS and Ethernet CPs 11; Of which max. 10 CP as DP master
Slots
● required slots 2
Time of day
Clock
● Hardware clock (real-time) Yes
● retentive and synchronizable Yes
● Resolution 1 ms
● Deviation per day (buffered), max. 1.7 s; Power off
● Deviation per day (unbuffered), max. 8.6 s; Power on
Operating hours counter
● Number 16
● Number/Number range 0 to 15
● Range of values SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
● Granularity 1h
● retentive Yes
Clock synchronization
● supported Yes
● to DP, master Yes
● to DP, slave Yes
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Possible as client and master/slave via SIMATIC process
Interfaces
Number of PROFINET interfaces 2
Number of RS 485 interfaces 1; PROFIBUS DP
Number of other interfaces 2; 2x synchronization
1. Interface
Interface type RS 485 / PROFIBUS
Isolated Yes
Number of connections 16
Interface types
● Output current of the interface, max. 150 mA
Protocols
● PROFIBUS DP master Yes
● PROFIBUS DP slave No
PROFIBUS DP master
● Number of connections, max. 16
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 96
● Number of slots per interface, max. 1 632
Services

6ES74105HX080AB0 Subject to change without notice


2/15/2024
Page 3/8 © Copyright Siemens
— PG/OP communication Yes
— Routing Yes; S7 routing
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Equidistance No
— Isochronous mode No
— SYNC/FREEZE No
— Activation/deactivation of DP slaves Yes; Approved for stand-alone operation only, not in conjunction with CiR
(Configuration in Run)
— Direct data exchange (slave-to-slave No
communication)
— DPV1 Yes
Address area
— Inputs, max. 6 kbyte
— Outputs, max. 6 kbyte
User data per DP slave
— User data per DP slave, max. 244 byte
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
2. Interface
Interface type PROFINET
Isolated Yes
automatic detection of transmission rate Yes; Autosensing
Autonegotiation Yes
Autocrossing Yes
System redundancy Yes
Redundant subnetworks Yes
Change of IP address at runtime, supported No
Number of connections 120
Interface types
● Number of ports 2
● integrated switch Yes
Protocols
● PROFINET IO Controller Yes
● PROFINET IO Device No
● PROFINET CBA No
● Open IE communication Yes
● Web server No
● Media redundancy Yes
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
Services
— PG/OP communication Yes
— S7 communication Yes
— Shared device No; however, usable as part of S7
— Prioritized startup No
— Number of connectable IO Devices, max. 250
— Number of connectable IO Devices for RT, max. 250
— of which in line, max. 250
— Activation/deactivation of IO Devices Yes; Approved for stand-alone operation only, not in conjunction with CiR
(Configuration in Run)
— IO Devices changing during operation (partner No
ports), supported
— Device replacement without swap medium Yes
— Send cycles 250 µs, 500 µs, 1 ms, 2 ms, 4 ms
— Updating time 250 µs to 512 ms, minimum value depends on the number of configured user
data and the configured single or redundant mode

6ES74105HX080AB0 Subject to change without notice


2/15/2024
Page 4/8 © Copyright Siemens
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
— User data consistency, max. 1 024 byte
Open IE communication
● Number of connections, max. 118
● Local port numbers used at the system end 0, 20, 21, 25, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534,
65535
● Keep-alive function, supported Yes
3. Interface
Interface type PROFINET
Isolated Yes
automatic detection of transmission rate Yes; Autosensing
Autonegotiation Yes
Autocrossing Yes
System redundancy Yes
Redundant subnetworks Yes
Number of connections 120
Interface types
● Number of ports 2
● integrated switch Yes
Protocols
● PROFINET IO Controller Yes
● PROFINET IO Device No
● PROFINET CBA No
● Open IE communication Yes
● Web server No
● Media redundancy Yes
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
Services
— PG/OP communication Yes
— S7 communication Yes
— Shared device No; however, usable as part of S7
— Prioritized startup No
— Number of connectable IO Devices, max. 250
— Number of connectable IO Devices for RT, max. 250
— of which in line, max. 250
— Activation/deactivation of IO Devices Yes; Approved for stand-alone operation only, not in conjunction with CiR
(Configuration in Run)
— IO Devices changing during operation (partner No
ports), supported
— Device replacement without swap medium Yes
— Send cycles 250 µs, 500 µs, 1 ms, 2 ms, 4 ms
— Updating time 250 µs to 512 ms, minimum value depends on the number of configured user
data and the configured single or redundant mode
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
— User data consistency, max. 1 024 byte
Open IE communication
● Number of connections, max. 118
● Local port numbers used at the system end 0, 20, 21, 25, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534,
65535
● Keep-alive function, supported Yes
4. Interface
Interface type Pluggable synchronization submodule (FO)
Plug-in interface modules Synchronization module 6ES7960-1AA06-0XA0, 6ES7960-1AB06-0XA0 or
6ES7960-1AA08-0XA0
5. Interface
Interface type Pluggable synchronization submodule (FO)
Plug-in interface modules Synchronization module 6ES7960-1AA06-0XA0, 6ES7960-1AB06-0XA0 or
6ES7960-1AA08-0XA0

6ES74105HX080AB0 Subject to change without notice


2/15/2024
Page 5/8 © Copyright Siemens
Protocols
Supports protocol for PROFINET IO Yes
PROFINET CBA No
PROFIsafe Yes
PROFIBUS Yes
AS-Interface Yes; Via add-on
Redundancy mode
Media redundancy
— Switchover time on line break, typ. < 200 ms
— Number of stations in the ring, max. 50
SIMATIC communication
● S7 routing Yes
Open IE communication
● TCP/IP Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 118
— Data length, max. 32 kbyte
— several passive connections per port, supported Yes
● ISO-on-TCP (RFC1006) Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs
— Number of connections, max. 118
— Data length, max. 32 kbyte; 1 452 bytes via CP 443-1 Adv.
● UDP Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 118
— Data length, max. 1 472 byte
Further protocols
● Foundation Fieldbus Yes; via DP/FF Link
● MODBUS Yes; Via add-on
communication functions / header
PG/OP communication Yes
● Number of connectable OPs without message processing 119
● Number of connectable OPs with message processing 119; When using Alarm_S/SQ and Alarm_D/DQ
Data record routing Yes
S7 communication
● supported Yes
● as server Yes
● as client Yes
● User data per job, max. 64 kbyte
● User data per job (of which consistent), max. 462 byte; 1 variable
S5 compatible communication
● supported Yes; via CP and FC AG_SEND and FC AG_RECV
● User data per job, max. 8 kbyte
● User data per job (of which consistent), max. 240 byte
● Number of simultaneous AG-SEND/AG-RECV orders per 64/64
CPU, max.
Standard communication (FMS)
● supported Yes; Via CP and loadable FB
Number of connections
● overall 120
● usable for PG communication
— reserved for PG communication 1
● usable for OP communication
— reserved for OP communication 1
S7 message functions
Number of login stations for message functions, max. 119; max. 119 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with
Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
Program alarms Yes
Process diagnostic messages Yes
simultaneously active Alarm-S blocks, max. 1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
Alarm 8-blocks Yes
● Number of instances for alarm 8 and S7 communication 10 000
blocks, max.
Process control messages Yes

6ES74105HX080AB0 Subject to change without notice


2/15/2024
Page 6/8 © Copyright Siemens
Number of archives that can log on simultaneously (SFB 37 64
AR_SEND)
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 4
Status/control
● Status/control variable Yes
● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max. 70
Diagnostic buffer
● present Yes
● Number of entries, max. 3 200
Service data
● can be read out Yes
Standards, approvals, certificates
CE mark Yes
UKCA mark Yes
CSA approval Yes
UL approval Yes
cULus Yes
FM approval Yes
RCM (formerly C-TICK) Yes
KC approval Yes
EAC (formerly Gost-R) Yes
CCC Yes
Use in hazardous areas
● ATEX ATEX II 3G Ex ec IIC T4 Gc
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 70 °C
configuration / header
configuration / programming / header
● Command set see instruction list
● Nesting levels 7
● Access to consistent data in process image Yes
● System functions (SFC) see instruction list
● System function blocks (SFB) see instruction list
Programming language
— SCL Yes
— CFC Yes
configuration / programming / number of simultaneously active SFC / header
— RD_REC 8; SFC 59; per interface
— WR_REC 8; SFC 58; per interface
— WR_PARM 8; SFC 55; per interface
— PARM_MOD 1; SFC 57; per interface
— WR_DPARM 2; SFC 56; per interface
— DPNRM_DG 8; SFC 13; per interface
— RDSYSST 8; SFC 51
— DP_TOPOL 1; SFC 103; per interface
configuration / programming / number of simultaneously active SFB / header
— RDREC 8; SFB 52; per interface, but not more than 32 across all external interfaces
— WRREC 8; SFB 53; per interface, but not more than 32 across all external interfaces
Know-how protection
● User program protection/password protection Yes
● Block encryption Yes; With S7 block Privacy
Dimensions
Width 50 mm
Height 290 mm
Depth 219 mm

6ES74105HX080AB0 Subject to change without notice


2/15/2024
Page 7/8 © Copyright Siemens
Weights
Weight, approx. 1.1 kg

last modified: 10/13/2023