0% found this document useful (0 votes)
115 views76 pages

Customer Service Quick Reference Guide

This document provides a quick reference guide for the EMC Symmetrix VMAX series customer service. It includes sections on the system layout, components within the system bay, front-end configuration options, and diagrams of components like the engine, directors, I/O modules, and environmental components. The guide aims to help technicians and customers understand and service the VMAX series storage arrays.

Uploaded by

Weimin Chen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
115 views76 pages

Customer Service Quick Reference Guide

This document provides a quick reference guide for the EMC Symmetrix VMAX series customer service. It includes sections on the system layout, components within the system bay, front-end configuration options, and diagrams of components like the engine, directors, I/O modules, and environmental components. The guide aims to help technicians and customers understand and service the VMAX series storage arrays.

Uploaded by

Weimin Chen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 76

EMC CONFIDENTIAL

EMC® Symmetrix®

VMAX™ Series

Customer Service Quick Reference Guide


P/N 300-008-367
REV A05

EMC Corporation
Hopkinton, MA 01748-9103
1-508-435-1000 (in North America) 1-866-464-7381
www.EMC.com
EMC CONFIDENTIAL

Copyright © 2010 - 2011 EMC Corporation. All rights reserved.

Published May 2011.

EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.

THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS IS.” EMC CORPORATION MAKES NO REPRESENTATIONS
OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY
DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the
most up-to-date regulatory document for your product line, go to the Technical Documentation and Advisories section on EMC
Powerlink.

For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com.

All other trademarks used herein are the property of their respective owners.

2 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Table of Contents
System Layout .......................................................................................................................................................................................................7
Symmetrix VMAX Front Door Light Bar ..............................................................................................................................................................9
Symmetrix VMAX System Bay ..........................................................................................................................................................................10
Symmetrix VMAX SE System Bay ....................................................................................................................................................................11
Symmetrix VMAX Storage Bay .........................................................................................................................................................................12
Three-Phase Power Configurations ..................................................................................................................................................................13
Single-Phase Power Configurations .................................................................................................................................................................14
Standard Configuration — Fully Populated Symmetrix VMAX System ............................................................................................................15
Extended Drive Loop Configuration — Fully Populated Symmetrix VMAX System .........................................................................................16
System Bay Components..................................................................................................................................................................................... 17
Symmetrix VMAX Engine — Front View ...........................................................................................................................................................19
Symmetrix VMAX Engine — Rear View ...........................................................................................................................................................20
Symmetrix VMAX Director ................................................................................................................................................................................21
Symmetrix VMAX Director Fault LED Indicator ................................................................................................................................................22
Back End I/O Modules — Fibre Channel ..........................................................................................................................................................23
Front End I/O Modules — 4-Port Fibre Channel ...............................................................................................................................................24
Front End I/O Modules — 2-Port FICON ..........................................................................................................................................................25
Front End I/O Modules — 2-Port GbE SRDF/iSCSI/FCoE ...............................................................................................................................26
System Interface Board (SIB) ...........................................................................................................................................................................27
Environmental Components ..............................................................................................................................................................................28
Server — Rear View .........................................................................................................................................................................................29
MIBE — Front View ..........................................................................................................................................................................................30
MIBE — Rear View ...........................................................................................................................................................................................31
MIBE Connections — Rear View ......................................................................................................................................................................32
I/O Module Carrier without Compression ..........................................................................................................................................................33
I/O Module Carrier with Compression ...............................................................................................................................................................34

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 3


EMC CONFIDENTIAL

Back End Fibre Channel I/O Module — I/O Module Slots 0 and 1 ...................................................................................................................35
Back End Fibre Channel I/O Module with Encryption — I/O Module Slots 0 and 1 ..........................................................................................36
4-Port Front End Fibre Channel I/O Module — I/O Module Slots 4 and 5 ........................................................................................................37
2-Port Front End GbE SRDF/iSCSI/FCoE I/O Module — I/O Module Slots 4 and 5 ........................................................................................38
2-Port Front End FICON I/O Module — I/O Module Slots 4 and 5 ...................................................................................................................39
Front-End Configuration....................................................................................................................................................................................... 41
Front End I/O Module Port Layout ....................................................................................................................................................................43
Fibre Channel Front-End Configurations ..........................................................................................................................................................44
Fibre Channel and FICON Front-End Configurations .......................................................................................................................................45
Fibre Channel and GbE iSCSI/FCoE Front-End Configurations .......................................................................................................................46
Fibre Channel, GbE iSCSI, FCoE, and SRDF Front-End Configurations .........................................................................................................47
Fibre Channel and GbE SRDF Front-End Configurations ................................................................................................................................48
FICON Front-End Configuration .......................................................................................................................................................................49
FICON, GbE iSCSI, FCoE, and SRDF Front-End Configurations ...................................................................................................................50
GbE iSCSI, FCoE and SRDF Front-End Configurations ..................................................................................................................................51
Back-End Configuration ....................................................................................................................................................................................... 53
Symmetrix VMAX DAE .....................................................................................................................................................................................55
Drive Capacities and Speeds ............................................................................................................................................................................56
Engine 4 Back-End Connections — Directors 7 (Odd) and 8 (Even) ...............................................................................................................57
Engine 5 Back-End Connections — Directors 9 (Odd) and 10 (Even) .............................................................................................................58
Engine 3 Back-End Connections — Directors 5 (Odd) and 6 (Even) ...............................................................................................................59
Engine 6 Back-End Connections — Directors 11 (Odd) and 12 (Even) ...........................................................................................................60
Engine 2 Back-End Connections — Directors 3 (Odd) and 4 (Even) ...............................................................................................................61
Engine 7 Back-End Connections — Directors 13 (Odd) and 14 (Even) ...........................................................................................................62
Engine 1 Back-End Connections — Directors 1 (Odd) and 2 (Even) ...............................................................................................................63
Engine 8 Back-End Connections — Directors 15 (Odd) and 16 (Even) ...........................................................................................................64
Symmetrix VMAX SE Back-End Connections — Direct-Connect Cables .........................................................................................................65
Symmetrix VMAX SE Back-End Connections — Daisy-Chain Cables .............................................................................................................66
Part Numbers ....................................................................................................................................................................................................... 67

4 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Main Components .............................................................................................................................................................................................69


Back-End Cables ..............................................................................................................................................................................................73
MIBE 3.125 GBPS QSFP Cables with Boss Backshell ....................................................................................................................................74
RS-232 Sense Cables ......................................................................................................................................................................................76

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 5


EMC CONFIDENTIAL

6 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


SYSTEM LAYOUT
EMC CONFIDENTIAL

Symmetrix VMAX Front Door Light Bar

Symmetrix VMAX system Symmetrix VMAX SE


and storage bays system bay
#38 #37

Light bar

SYM-002079

Part number information about components #37 and #38 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 9


EMC CONFIDENTIAL

Symmetrix VMAX System Bay


MIBE power supplies/
MIBE B MIBE A
cooling modules

Engine 8

!
!
A B C D

Engine 7

!
!
ON
ON I
I
O
O OFF
OFF

A B C D

! ! ! !

ON
ON I
I
O
O OFF
OFF

Engine 6

!
!
A B C D
ON
ON I
I
O
O OFF
OFF

Engine 5

!
!
A B C D

UPS UPS
KVM #13
#15 KVM
Engine 4

!
!
A B C D
PDU
(behind PDP)
Engine 3

!
!

A B C D PDP
LAN1
LAN2

Server Server
#14

Engine 2

!
!

A B C D

Engine 1
!
!

SPS
A B C D
SPS #11

System bay (front) System bay (rear)


SYM-001697

Part number information about components #11, #13, #14, and #15 is available on Table 1 on page 69.

10 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Symmetrix VMAX SE System Bay

DAE 8

!
!
EXP PRI

!
B EXP PRI
#

PRI EXP
A #

!
PRI EXP

!
!
DAE 7

!
!
EXP PRI

!
B EXP PRI
#

PRI EXP
A #

!
PRI EXP

!
!
DAE 6
ON ON

!
I I

!
O O
OFF OFF

EXP PRI

!
B EXP PRI
#

PRI EXP
A #

!
PRI EXP

PDU

!
!
DAE 5

!
!
EXP PRI

!
ON B EXP PRI
#
ON
I I
PRI EXP
O A #
O
OFF OFF

!
PRI EXP

!
!
SPS 2A SPS 2B SPS 2A
UPS ON
I
O
OFF
ON
I
O
OFF

LAN1
LAN2

Server
KVM
SPS A SPS B SPS A
MIBE power
supply/cooling
! ! ! !

MIBE B MIBE A
modules
Engine 4

!
!
A B C D

!
DAE 4

!
EXP PRI

!
#
B EXP PRI

PRI EXP
A #

!
PRI EXP

PDP

!
!
!
DAE 3

!
EXP PRI

!
B EXP PRI
#

PRI EXP
A #

!
PRI EXP

!
!
DAE 2

!
!
EXP PRI

!
#
B EXP PRI

PRI EXP
A #

!
PRI EXP

!
!
DAE 1

!
!
EXP PRI

!
B EXP PRI
#

PRI EXP
A #

!
PRI EXP

!
!
SPS 1A SPS 1B SPS 1A

System bay (front) System bay (rear)


SYM-001698

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 11


EMC CONFIDENTIAL

Symmetrix VMAX Storage Bay

A
B

A
B

A
B

A
B
SPS SPS #11
! ! ! ! ! ! ! !

#
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
! ! ! !

! ! ! !

PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
#

#
Disk drives
ON
ON I
I
O
O OFF
OFF
! ! ! ! ! ! ! !

(15 per DAE)

A
B

A
B

A
B

A
B
ON
ON I
I ! ! ! ! ! ! ! !
O
O OFF
OFF

PDU

#
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
DAE power ON
I
O
!
!

!
!

!
!

!
!

ON
I
O
OFF

PRI

PRI

PRI

PRI
OFF

PRI

PRI

PRI

PRI
supply/cooling

EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
#

#
module ! ! ! ! ! ! ! !

A
B

A
B

A
B

A
B
LCC ! ! ! ! ! ! ! !

#
DAE covers

EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
! ! ! !

! ! ! !

PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
#

#
PDP ! ! ! ! ! ! ! !

A
B

A
B

A
B

A
B
! ! ! ! ! ! ! !

#
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
PRI

PRI

PRI

PRI
SPS cover

PRI

PRI

PRI

PRI
! ! ! !

! ! ! !

PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
#

#
! ! ! ! ! ! ! !

Power zone B Power zone A


left side right side
Storage bay (front) Storage bay (rear)
SYM-001699

Part number information about component #11 is available on Table 1 on page 69.

12 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Three-Phase Power Configurations

Symmetrix VMAX system bay Symmetrix VMAX SE system bay Symmetrix VMAX storage bay

ON
I
O
OFF

ON
I
O
OFF

PDU ON
I
O
OFF
ON
I
O
OFF

#2
ON
I
O
OFF

ON
I
O
OFF

ON
I
O
OFF

ON
I
O
OFF

ON
I
O
OFF

O
OFF

O
OFF

ON

PDP
I

ON

#3, #4
I
O
ON OFF
I
O
OFF O
OFF

ON
I ON
I
O
OFF

O
OFF

ON
I

ON
I
ON
O I
OFF
O
OFF

ON
I
I
O
OFFO

4 PDUs 2 PDUs (upper) 2 PDUs (upper)


2 PDPs (lower) 2 PDPs (lower) 2 PDPs (lower)
SYM-001677

Part number information about components #2, #3,and #4 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 13


EMC CONFIDENTIAL

Single-Phase Power Configurations

Symmetrix VMAX system bay Symmetrix VMAX SE system bay Symmetrix VMAX storage bay

ON
I

PDU
O
OFF

ON
I
O
OFF

ON
I

#2
O
OFF

ON
I
O
OFF

ON
I
O
OFF

ON
I
O
ON OFF
I
O
OFF

ON
I
O
ON OFF
I
O
OFF
ON
I
O
OFF

ON
I
O
OFF

ON
I
O
OFF

ON
I
O
OFF

PDP O
OFF

ON
I
O
OFF

ON
I

#5 ON
I
O
OFF O
OFF
ON
I
O
OFF O
OFF

ON
I

ON
I ON
I
O
OFF

O
OFF

ON
I

O
OFF

ON
I

ON
I
ON
O I
OFF
O ON
OFF
I
I
O
OFFO

4 PDUs 2 PDUs (upper) 4 PDUs


4 PDPs 2 PDPs (lower) 4 PDPs
SYM-001678

Part number information about components #2 and #5 is available on Table 1 on page 69.

14 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Standard Configuration — Fully Populated Symmetrix VMAX System

Storage bays Rear view Storage bays


system bay

888 66 5 5 777
Engine 8
Dir 15/16
Engine 7
Dir 13/14
Engine 6
Dir 11/12
Engine 5
Dir 9/10

111 33 4 4 2 2 2
Engine 4
Dir 7/8

Engine 3
Dir 5/6

Engine 2
Dir 3/4

Engine 1
Dir 1/2

Daisy full Daisy full Direct full Daisy full Direct full Direct full Daisy full Direct full Daisy full Daisy full
3D 2D 1D 2B 1B 1A 2A 1C 2C 3C
SYM-001702

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 15


EMC CONFIDENTIAL

Extended Drive Loop Configuration — Fully Populated Symmetrix VMAX System

Rear view
Storage bays Storage bays
system bay

66666 5 5 5 5 5 Engine 6
Dir 11/12
Engine 5
Dir 9/10

33333 4 4 4 4 4
Engine 4
Dir 7/8

Engine 3
Dir 5/6

Daisy full Daisy full Daisy full Daisy full Direct full Direct full Daisy full Daisy full Daisy full Daisy full
5B 4B 3B 2B 1B 1A 2A 3A 4A 5A
SYM-001703

16 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


SYSTEM BAY COMPONENTS
EMC CONFIDENTIAL

Symmetrix VMAX Engine — Front View

Engine power Engine cooling fans Engine power


supply A supply B
#9 #1 #9

A A B B C C D D
SYM-001696

Part number information about components #1 and #9 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 19


EMC CONFIDENTIAL

Symmetrix VMAX Engine — Rear View

System Interface
Board (SIB)
Back End
I/O Modules
I/O Module
(slots 2 & 3)
(slot 0)

Back End
I/O Module AC power
connector (slot 1) connector r
irecto
nd
Eve r
ire cto
dd
Od

Front-end Front-end
ports of ports of
even director odd director
Management Front End Front End Management
Module B I/O Modules I/O Modules Module A
#19 (slot 4) (slot 5) #19 SYM-001689

Part number information about component #19 is available on Table 1 on page 69.

20 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Symmetrix VMAX Director

Cache Memory Modules


#17

VMAX director
#23

SYM-002083

Part number information about components #17 and #23 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 21


EMC CONFIDENTIAL

Symmetrix VMAX Director Fault LED Indicator

▲ Fault LED status Board operating mode


OFF Board not powered
Amber light blinking at 1/4 Hz Booting BIOS, POST or loading Enginuity™
Amber light blinking at 1 Hz Booting POST
Boot process OFF Enginuity loaded
Flash reprogramming during POST Amber light rapidly blinking Flash reprogramming in bursts
Amber light OFF Director operates normally
Regular operation Amber light ON Director faulted

22 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Back End I/O Modules — Fibre Channel

C0, C1, D0, D1


A0, A1, B0, B1

r
irecto
nd
Eve r
ire cto
dd
Od

A0, A1, B0, B1


C0, C1, D0, D1 SYM-001684

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 23


EMC CONFIDENTIAL

Front End I/O Modules — 4-Port Fibre Channel

r
irecto
nd
Eve r
ire cto
dd
Od

E0, E1, F0, F1 E0, E1, F0, F1

G0, G1, H0, H1 G0, G1, H0, H1 SYM-001685

24 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Front End I/O Modules — 2-Port FICON

c tor
n dire
Eve
ctor
d dire
Od

E0, E1 E0, E1

G0, G1 G0, G1 SYM-001686

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 25


EMC CONFIDENTIAL

Front End I/O Modules — 2-Port GbE SRDF/iSCSI/FCoE

c tor
n dire
Eve
ctor
d dire
Od

E0, F0 E0, F0

G0, H0 G0, H0 SYM-001687

26 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

System Interface Board (SIB)

MIBE A connector

MIBE B connector

System Interface
B
SR
IO
A Board (SIB)

IO
R
#20

S
b
3G
3 Gb SRIO

Power

Rack ID Enclosure ID Service


SIB

SYM-001690

Part number information about component #20 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 27


EMC CONFIDENTIAL

Environmental Components

Engine power Engine power


supply B supply A
c tor
n dire
Eve
ctor
d dire
Od

Management Management
Module B Module A SYM-001688

28 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Server — Rear View

Ethernet to Management Module A


Modem serial port of the lowest engine in system bay

PS2 mouse to KVM CS spare port

Power from UPS Video to KVM USB Customer network

PS2 keyboard to KVM Ethernet to Management Module B Server


of the highest engine in system bay #14
SYM-002084

Part number information about component #14 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 29


EMC CONFIDENTIAL

MIBE — Front View

MIBE power supply/


cooling module
#10

SYM-001695

Part number information about component #10 is available on Table 1 on page 69.

30 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

MIBE — Rear View

Port 2 Port 6 Port 8 Port 12


Port 0 Port 4 Port 10 Port 14

Port 1 Port 5 Port 11 Port 15


Port 3 Port 7 Port 9 Port 13

MIBE B assembly
#18

MIBE A assembly
#18

SYM-002078

Part number information about component #18 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 31


EMC CONFIDENTIAL

MIBE Connections — Rear View

MIBE B MIBE A

Dir 9 Dir 11 Dir 13 Dir 15 Dir 1 Dir 3 Dir 5 Dir 7 Dir 9 Dir 11 Dir 13 Dir 15 Dir 1 Dir 3 Dir 5 Dir 7
SIB-B SIB-B SIB-B SIB-B SIB-B SIB-B SIB-B SIB-B SIB-A SIB-A SIB-A SIB-A SIB-A SIB-A SIB-A SIB-A
Dir 10 Dir 12 Dir 14 Dir 16 Dir 2 Dir 4 Dir 6 Dir 8 Dir 10 Dir 12 Dir 14 Dir 16 Dir 2 Dir 4 Dir 6 Dir 8
SIB-B SIB-B SIB-B SIB-B SIB-B SIB-B SIB-B SIB-B SIB-A SIB-A SIB-A SIB-A SIB-A SIB-A SIB-A SIB-A

Power

Rack ID Enclosure ID Service


SIB

SIB B port SIB A port SYM-002081

32 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

I/O Module Carrier without Compression

FAN module

I/O module carrier


#21

Power LED
Midplane connector
Chassis screw

Pull ring
I/O module I/O module
Fault LED slot 4 slot 5
SYM-001680

Part number information about component #21 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 33


EMC CONFIDENTIAL

I/O Module Carrier with Compression

Midplane connector
FAN module

I/O Module carrier with compression


#22

Power LED
Compression label
Chassis screw

Pull ring
I/O module I/O module
Fault LED slot 4 slot 5
SYM-001681

Part number information about component #22 is available on Table 1 on page 69.

34 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Back End Fibre Channel I/O Module — I/O Module Slots 0 and 1

Back End I/O Module


#24

bre
Fi
b
4G
4 Gb Fibre

0 1 2 3
SYM-002491

Part number information about component #24 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 35


EMC CONFIDENTIAL

Back End Fibre Channel I/O Module with Encryption — I/O Module Slots 0 and 1

Back End I/O Module


with encryption
#25

bre
Fi
b
4G
4 Gb Fibre

0 1 2 3
SYM-002491_encryption

Part number information about component #25 is available on Table 1 on page 69.

36 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

4-Port Front End Fibre Channel I/O Module — I/O Module Slots 4 and 5

SFP SM module (4 Gb Fibre) SFP+ SM module (8 Gb Fibre)


#33 #35

Front End Fibre Channel Front End Fibre Channel


I/O Module I/O Module
#26 #30
4 Gb Fibre 0 1 2 3 8 Gb Fibre

SFP MM module (4 Gb Fibre) SFP+ MM module (8 Gb Fibre)


#32 0 #34
1

2
3

bre
3

Fi
b
4G
Fibre Channel 4-port I/O module options

MM MM MM MM SM SM SM SM MM MM SM MM SM MM SM MM

4 MM ports 4 SM ports 3 MM, 1 SM ports 2 MM, 2 SM ports SYM-001692

Part number information about components #26, #30, #32, #32, #34, and #35 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 37


EMC CONFIDENTIAL

2-Port Front End GbE SRDF/iSCSI/FCoE I/O Module — I/O Module Slots 4 and 5

SFP MM module (10 GbE iSCSI/FCoE) SFP MM module (1 GbE iSCSI)


#36 #32

10 GbE iSCSI/FCoE 0 1 1 Gb IPSEC/iSCSI

Front End GbE iSCSI/FCoE Front End GgE iSCSI


I/O Module I/O Module
#29 #28
0
C
1
IPSE
bE
1G

GbE iSCSI/FCoE 2-port I/O module option

MM MM

2 MM ports SYM-001693

Part number information about components #28, #29, #32 ,and #36 is available on Table 1 on page 69. The FCoE option is only available
with the 10 GbE I/O module and Enginuity 5875.

38 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

2-Port Front End FICON I/O Module — I/O Module Slots 4 and 5

SFP SM module (4 Gb Fibre) SFP+ SM module (8 Gb Fibre)


#33 #35

FICON Front End FICON Front End


I/O Module I/O Module
#27 #31
4 Gb Fibre/FICON 0 1 8 Gb Fibre/FICON

SFP MM module (4 Gb Fibre) SFP+ MM module (8 Gb Fibre)


#32 0
#34
1

N
O
IC
/F
re
ib
F
b
4G
FICON 2-port I/O module options

MM MM SM SM

2 MM ports 2 SM ports SYM-001694

Part number information about components #27, #31, #32, #33, #34, and #35 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 39


EMC CONFIDENTIAL

40 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


FRONT-END CONFIGURATION
EMC CONFIDENTIAL

Front End I/O Module Port Layout

Even director Odd director


I/O module slots
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5

GbE SRDF/iSCSI/FCoE Fibre Channel FICON

Front End I/O Modules E0 F0 G0 H0 E0 E1* F0 F1* G0 G1* H0 H1* E1E1


E0E0 GG0G1G1
G0G0
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5

*Note: When Fibre Channel SRDF is configured, these ports are unavailable
SYM-001704

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 43


EMC CONFIDENTIAL

Fibre Channel Front-End Configurations

FA-7H FA FA FA-8H
16 FC engine FA-7G FA FA FA-8G
FA-7F FA FA FA-8F
Even director Odd director FA-7E FA FA FA-8E
DA-7D DA DA DA-8D
E0 E1 F0 F1 G0 G1 H0 H1 E0 E1 F0 F1 G0 G1 H0 H1
DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5
DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RF-7H RF RF RF-8H
FA-7G FA FA FA-8G
12 FC / 2 FC SRDF engine FA-7F FA FA FA-8F
Even director Odd director FA-7E FA FA FA-8E
DA-7D DA DA DA-8D
E0 E1 F0 F1 G0 G1 H0 E0 E1 F0 F1 G0 G1 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RF-7H RF RF RF-8H
RF-7G RF RF RF-8G
FA-7F FA FA FA-8F
8 FC / 4 FC SRDF FC engine FA-7E FA FA FA-8E
Even director Odd director DA-7D DA DA DA-8D
DA-7C DA DA DA-8C
E0 E1 F0 F1 G0 H0 E0 E1 F0 F1 G0 H0 DA-7B DA DA DA-8B
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7A DA DA DA-8A
Odd Even
SYM-001705

44 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Fibre Channel and FICON Front-End Configurations

EE EE
EF-7G EF EF EF-8G
8 FC / 4 FICON engine FA-7F FA FA FA-8F
FA-7E FA FA FA-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 E1 F0 F1 G0 G1 E0 E1 F0 F1 G0 G1 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

EE EE
EF-7G EF EF EF-8G
4 FICON / 4 FC / 2 FC SRDF engine RF-7F RF RF RF-8F
FA-7E FA FA FA-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 E1 F0 G0 G1 E0 E1 F0 G0 G1 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

EE EE
EF-7G EF EF EF-8G
4 FICON / 4 FC SRDF engine RF-7F RF RF RF-8F
RF-7E RF RF RF-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 F0 G0 G1 E0 F0 G0 G1 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-001706

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 45


EMC CONFIDENTIAL

Fibre Channel and GbE iSCSI/FCoE Front-End Configurations

SE/FE-7H SE/FE SE/FE SE/FE-8H


SE/FE-7G SE/FE SE/FE SE/FE-8G
8 FC / 4 GbE iSCSI or FCoE engine FA-7F FA FA FA-8F
FA-7E FA FA FA-8E
Even director Odd director DA-7D DA DA DA-8D
E0 E1 F0 F1 G0 H0 E0 E1 F0 F1 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

SE/FE-7H SE/FE SE/FE SE/FE-8H


SE/FE-7G SE/FE SE/FE SE/FE-8G
4 GbE iSCSI or FCoE / 4 FC SRDF engine RF-7F RF RF RF-8F
RF-7E RF RF RF-8E
Even director Odd director DA-7D DA DA DA-8D
E0 F0 G0 H0 E0 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

SE/FE-7H SE/FE SE/FE SE/FE-8H


SE/FE-7G SE/FE SE/FE SE/FE-8G
4 GbE iSCSI or FCoE / 4 FC / 2 FC SRDF engine RF-7F RF RF RF-8F
FA-7E FA FA FA-8E
Even director Odd director DA-7D DA DA DA-8D
E0 E1 F0 G0 H0 E0 E1 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-001707

NOTE: The FCoE option is only available with the 10 GbE I/O module and Enginuity 5875. iSCSI options are available with the 1 GbE I/O
module (Enginuity 5874 and higher) and 10 GbE I/O module (Enginuity 5875). Page 38 provides information about GbE Front End I/O
Modules.

46 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Fibre Channel, GbE iSCSI, FCoE, and SRDF Front-End Configurations

RE-7H RE RE RE-8H
SE/FE-7G SE/FE SE/FE SE/FE-8G
8 FC / 2 GbE iSCSI or FCoE / 2 GbE SRDF engine FA-7F FA FA FA-8F
FA-7E FA FA FA-8E
Even director Odd director DA-7D DA DA DA-8D
E0 E1 F0 F1 G0 H0 E0 E1 F0 F1 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-001708

NOTE: The FCoE option is only available with the 10 GbE I/O module and Enginuity 5875. iSCSI options are available with the 1 GbE I/O
module (Enginuity 5874 and higher) and 10 GbE I/O module (Enginuity 5875). Page 38 provides information about GbE Front End I/O
Modules.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 47


EMC CONFIDENTIAL

Fibre Channel and GbE SRDF Front-End Configurations

RE-7H RE RE RE-8H
8 FC / 4 GbE SRDF engine RE-7G RE RE RE-8G
FA-7F FA FA FA-8F
Even director Odd director FA-7E FA FA FA-8E
G0 H0 G0 H0 DA-7D DA DA DA-8D
E0 E1 F0 F1 E0 E1 F0 F1
DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5
DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-001709

48 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

FICON Front-End Configuration

EE EE
EF-7G EF EF EF-8G
8 FICON engine EE EE
EF-7E EF EF EF-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 E1 G0 H0 E0 E1 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-001710

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 49


EMC CONFIDENTIAL

FICON, GbE iSCSI, FCoE, and SRDF Front-End Configurations

RE-7H RE RE RE-8H
RE-7G RE RE RE-8G
4 FICON / 4 GbE SRDF engine EE EE
EF-7E EF EF EF-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 E1 G0 H0 E0 E1 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

SE-7H SE SE SE-8H
SE-7G SE SE SE-8G
4 FICON / 4 GbE iSCSI engine EE EE
EF-7E EF EF EF-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 E1 E1 G0 H0 E0 E1 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RE-7H RE RE RE-8H
SE-7G SE SE SE-8G
4 FICON / 2 GbE iSCSI / 2 GbE SRDF engine EE EE
EF-7E EF EF EF-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 E1 G0 H0 E0 E1 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module
E1 slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-002076

NOTE: The FCoE option is only available with the 10 GbE I/O module and Enginuity 5875. iSCSI options are available with the 1 GbE I/O
module (Enginuity 5874 and higher) and 10 GbE I/O module (Enginuity 5875). Page 38 provides information about GbE Front End I/O
Modules.

50 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

GbE iSCSI, FCoE and SRDF Front-End Configurations

SE/FE-7H SE/FE SE/FE SE/FE-8H


SE/FE-7G SE/FE SE/FE SE/FE-8G
8 GbE iSCSI or FCoE engine SE/FE-7F SE/FE SE/FE SE/FE-8F
SE/FE-7E SE/FE SE/FE SE/FE-8E
Even director Odd director DA-7D DA DA DA-8D
E0 F0 G0 H0 E0 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RE-7H RE RE RE-8H
SE/FE-7G SE/FE SE/FE SE/FE-8G
6 GbE iSCSI or FCoE/ 2 GbE SRDF engine SE/FE-7F SE/FE SE/FE SE/FE-8F
SE/FE-7E SE/FE SE/FE SE/FE-8E
Even director Odd director DA-7D DA DA DA-8D
E0 F0 G0 H0 E0 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RE-7H RE RE RE-8H
RE-7G RE RE RE-8G
4 GbE iSCSI or FCoE / 4 GbE SRDF engine SE/FE-7F SE/FE SE/FE SE/FE-8F
SE/FE-7E SE/FE SE/FE SE/FE-8E
Even director Odd director DA-7D DA DA DA-8D
E0 F0 G0 H0 E0 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-002077

NOTE: The FCoE option is only available with the 10 GbE I/Omodule and Enginuity 5875. iSCSI options are available with the 1 GbE I/O
module (Enginuity 5874 and higher) and 10 GbE I/O module (Enginuity 5875). Page 38 provides information about GbE Front End I/O
Modules.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 51


EMC CONFIDENTIAL

52 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


BACK-END CONFIGURATION
EMC CONFIDENTIAL

Symmetrix VMAX DAE

DAE chassis
#6

A
B
DAE power supply/ ! !

LCC
cooling module (side B)
(side A)
#7
#8

EXP

EXP
PRI

PRI
!

PRI

PRI
EXP

EXP

#
! !

SYM-002080

Part number information about components #6, #7, and #8 is available on Table 1 on page 69.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 55


EMC CONFIDENTIAL

Drive Capacities and Speeds

Fibre Channel

Enterprise Flash Drives (EFD)

SATA II

NOTE: The most recent drive information is available on MyGSIntranet, in the Parts Compatibility Database.

56 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Engine 4 Back-End Connections — Directors 7 (Odd) and 8 (Even)

System bay Storage bay 1A

Engine 8
DAE 3 LCCB (P1)
DAE 7 LCCB (P2)
DAE 4 LCCB (P3) Engine 7
DAE 8 LCCB (P4)

DAE 1 LCCA (P1) Engine 6


DAE 5 LCCA (P2)
DAE 2 LCCA (P3)
Engine 5
DAE 6 LCCA (P4)

DAE 1 LCCB (P1)

SPS
2B
DAE 5 LCCB (P2)

DAE 8

DAE 7

DAE 6

DAE 5
DAE 2 LCCB (P3)

SPS
DAE 6 LCCB (P4)

2A
Engine 3

DAE 3 LCCA (P1)

SPS
1B
DAE 7 LCCA (P2) Engine 2

DAE 4

DAE 3

DAE 2

DAE 1
DAE 4 LCCA (P3)
DAE 8 LCCA (P4)

SPS
1A
Engine 1

SYM-002091

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 57


EMC CONFIDENTIAL

Engine 5 Back-End Connections — Directors 9 (Odd) and 10 (Even)

System bay Storage bay 1A

SPS
4B
DAE 11 LCCB (P1) Engine 8

DAE 16

DAE 15

DAE 14

DAE 13
DAE 15 LCCB (P2)
DAE 12 LCCB (P3)

SPS
4A
DAE 16 LCCB (P4) Engine 7

DAE 9 LCCB (P1)

SPS
3B
Engine 6
DAE 13 LCCB (P2)

DAE 12

DAE 11

DAE 10

DAE 9
DAE 10 LCCB (P3)

SPS
DAE 14 LCCB (P4)

3A
DAE 9 LCCA (P1)
DAE 13 LCCA (P2) Engine 4
DAE 10 LCCA (P3)
DAE 14 LCCA (P4)
Engine 3
DAE 11 LCCA (P1)
DAE 15 LCCA (P2)
DAE 12 LCCA (P3) Engine 2
DAE 16 LCCA (P4)

Engine 1

SYM-002092

58 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Engine 3 Back-End Connections — Directors 5 (Odd) and 6 (Even)

Storage bay 1B System bay

Engine 8
DAE 3 LCCA (P1)
DAE 7 LCCA (P2)
DAE 4 LCCA (P3) Engine 7
DAE 8 LCCA (P4)

DAE 3 LCCB (P1) Engine 6


DAE 7 LCCB (P2)
DAE 4 LCCB (P3)
Engine 5
DAE 8 LCCB (P4)

DAE 1 LCCB (P1)


SPS
2B
Engine 4
DAE 5 LCCB (P2)
DAE 8

DAE 7

DAE 6

DAE 5
DAE 2 LCCB (P3)
SPS

DAE 6 LCCB (P4)


2A

DAE 1 LCCA (P1)


SPS
1B

DAE 5 LCCA (P2) Engine 2


DAE 4

DAE 3

DAE 2

DAE 1

DAE 2 LCCA (P3)


DAE 6 LCCA (P4)
SPS
1A

Engine 1

SYM-002093

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 59


EMC CONFIDENTIAL

Engine 6 Back-End Connections — Directors 11 (Odd) and 12 (Even)

Storage bay 1B System bay

SPS
4B
DAE 11 LCCB (P1) Engine 8

DAE 16

DAE 15

DAE 14

DAE 13
DAE 15 LCCB (P2)
DAE 12 LCCB (P3)

SPS
4A
DAE 16 LCCB (P4) Engine 7

DAE 9 LCCB (P1)

SPS
3B
DAE 13 LCCB (P2)
DAE 12

DAE 11

DAE 10

DAE 9
DAE 10 LCCB (P3)

SPS
DAE 14 LCCB (P4)
3A
Engine 5

DAE 11 LCCA (P1)


DAE 15 LCCA (P2) Engine 4
DAE 12 LCCA (P3)
DAE 16 LCCA (P4)
Engine 3
DAE 9 LCCA (P1)
DAE 13 LCCA (P2)
DAE 10 LCCA (P3) Engine 2
DAE 14 LCCA (P4)

Engine 1

SYM-002094

60 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Engine 2 Back-End Connections — Directors 3 (Odd) and 4 (Even)

System bay Storage bay 1C

Engine 8 DAE 1 LCCB (P1)


DAE 5 LCCB (P2)
DAE 2 LCCB (P3)
Engine 7 DAE 6 LCCB (P4)

Engine 6 DAE 3 LCCB (P1)


DAE 7 LCCB (P2)
DAE 4 LCCB (P3)
Engine 5 DAE 8 LCCB (P4)

DAE 3 LCCA (P1)

SPS
DAE 7 LCCA (P2)

2B
Engine 4

DAE 8

DAE 7

DAE 6

DAE 5
DAE 4 LCCA (P3)
DAE 8 LCCA (P4)

SPS
2A
Engine 3

SPS
1B
DAE 1 LCCA (P1)

DAE 4

DAE 3

DAE 2

DAE 1
DAE 5 LCCA (P2)
DAE 2 LCCA (P3)

SPS
1A
Engine 1 DAE 6 LCCA (P4)

SYM-002095

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 61


EMC CONFIDENTIAL

Engine 7 Back-End Connections — Directors 13 (Odd) and 14 (Even)

System bay Storage bay 1C

SPS
4B
DAE 9 LCCB (P1) Engine 8

DAE 16

DAE 15

DAE 14

DAE 13
DAE 13 LCCB (P2)
DAE 10 LCCB (P3)

SPS
4A
DAE 14 LCCB (P4)

DAE 9 LCCA (P1)

SPS
3B
Engine 6
DAE 13 LCCA (P2)

DAE 12

DAE 11

DAE 10

DAE 9
DAE 10 LCCA (P3)

SPS
DAE 14 LCCA (P4)

3A
Engine 5

DAE 11 LCCA (P1)


DAE 15 LCCA (P2) Engine 4
DAE 12 LCCA (P3)
DAE 16 LCCA (P4)
Engine 3
DAE 11 LCCB (P1)
DAE 15 LCCB (P2)
DAE 12 LCCB (P3) Engine 2
DAE 16 LCCB (P4)

Engine 1

SYM-002096

62 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Engine 1 Back-End Connections — Directors 1 (Odd) and 2 (Even)

Storage bay 1D System bay

DAE 3 LCCB (P1) Engine 8


DAE 7 LCCB (P2)
DAE 4 LCCB (P3)
DAE 8 LCCB (P4) Engine 7

DAE 3 LCCA (P1)


Engine 6
DAE 7 LCCA (P2)
DAE 4 LCCA (P3)
DAE 8 LCCA (P4)
Engine 5

DAE 1 LCCB (P1)

SPS
2B DAE 5 LCCB (P2) Engine 4
DAE 8

DAE 7

DAE 6

DAE 5
DAE 2 LCCB (P3)
DAE 6 LCCB (P4)
SPS
2A

Engine 3
DAE 1 LCCA (P1)
DAE 5 LCCA (P2)
SPS
1B

DAE 2 LCCA (P3) Engine 2


DAE 4

DAE 3

DAE 2

DAE 1

DAE 6 LCCA (P4)


SPS
1A

SYM-002097

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 63


EMC CONFIDENTIAL

Engine 8 Back-End Connections — Directors 15 (Odd) and 16 (Even)

Storage bay 1D System bay

SPS
4B
DAE 9 LCCB (P1)

DAE 16

DAE 15

DAE 14

DAE 13
DAE 13 LCCB (P2)
DAE 10 LCCB (P3)

SPS
4A
DAE 14 LCCB (P4) Engine 7

DAE 9 LCCA (P1)

SPS
3B
Engine 6
DAE 13 LCCA (P2)

DAE 12

DAE 11

DAE 10

DAE 9
DAE 10 LCCA (P3)

SPS
DAE 14 LCCA (P4)

3A
Engine 5

DAE 11 LCCA (P1)


DAE 15 LCCA (P2) Engine 4
DAE 12 LCCA (P3)
DAE 16 LCCA (P4)
Engine 3
DAE 11 LCCB (P1)
DAE 15 LCCB (P2)
DAE 12 LCCB (P3) Engine 2
DAE 16 LCCB (P4)

Engine 1

SYM-002098

64 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Symmetrix VMAX SE Back-End Connections — Direct-Connect Cables

OFF

OFF

OFF
ON

ON

ON
O

O
I

I
A
B

A
B

A
B

A
B
A
B

A
B

A
B

A
B

System bay (rear)


DAE 1

DAE 2

DAE 3

DAE 4

DAE 5

DAE 6

DAE 7

DAE 8
! ! ! ! ! ! ! ! ! ! ! ! ! ! ! !

#
EXP

EXP

EXP

EXP

EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP

EXP

EXP

EXP

EXP
PRI

PRI

PRI

PRI

PRI

PRI

PRI

PRI

Top
PRI

PRI

PRI

PRI

PRI

PRI

PRI

PRI
! ! ! ! ! ! ! !

! ! ! ! ! ! ! !

PRI

PRI

PRI

PRI

PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI

PRI

PRI

PRI

PRI
EXP

EXP

EXP

EXP

EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP

EXP

EXP

EXP

EXP
#

#
! ! ! ! ! ! ! ! ! ! ! ! ! ! ! !

OFF

OFF

OFF
ON

ON

ON
O

O
I

I
SYM-002082

NOTE: Table 2 on page 73 provides part number information about back-end cables.

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 65


EMC CONFIDENTIAL

Symmetrix VMAX SE Back-End Connections — Daisy-Chain Cables

OFF

OFF

OFF
ON

ON

ON
O

O
I

I
A
B

A
B

A
B

A
B
A
B

A
B

A
B

A
B

System bay (rear)


MIBE B
SPS 1B

SPS 2B SPS 2A
DAE 1

DAE 2

DAE 3

DAE 4

SPS B

DAE 5

DAE 6

DAE 7

DAE 8
! ! ! ! ! ! ! ! ! ! ! ! ! ! ! !

Engine

Server
#

#
Open
EXP

EXP

EXP

EXP

EXP

EXP

EXP

EXP
UPS
EXP

EXP

EXP

EXP

EXP

EXP

EXP

EXP
KVM
PRI

PRI

PRI

PRI

PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI

PRI

PRI

PRI

PRI
! ! ! ! ! ! ! !

! ! ! ! ! ! ! !

SPS 1A

MIBE A
PRI

PRI

PRI

PRI

PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI

PRI

PRI

PRI

PRI
SPS A
EXP

EXP

EXP

EXP

EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP

EXP

EXP

EXP

EXP
#

#
! ! ! ! ! ! ! ! ! ! ! ! ! ! ! !

OFF

OFF

OFF
ON

ON

ON
O

O
I

Top
DAE 16 DAE 15
DAE 4

OFF

OFF

OFF
ON

ON

ON
O

O
I

I
!

!
!

!
EXP PRI EXP PRI EXP PRI EXP PRI
!

!
# A # A # A # A
EXP PRI EXP PRI EXP PRI EXP PRI
DAE 3

PRI EXP B PRI EXP B PRI EXP B PRI EXP B


# # # #
!

!
PRI EXP PRI EXP PRI EXP PRI EXP

DAE 8 DAE 12
!

Storage bay (rear)


!

!
!

!
!

!
EXP PRI EXP PRI EXP PRI EXP PRI
!

!
# A # A # A # A
EXP PRI EXP PRI EXP PRI EXP PRI

PRI EXP B PRI EXP B PRI EXP B PRI EXP B


# # # #
!

!
PRI EXP PRI EXP PRI EXP PRI EXP

DAE 7 DAE 11
!

!
!

DAE 14 DAE 13
DAE 2

SPS 1A SPS 1B SPS 2A SPS 2B SPS 3A SPS 3B SPS 4A SPS 4B


!

!
!

!
EXP PRI EXP PRI EXP PRI EXP PRI
!

!
# A # A # A # A
EXP PRI EXP PRI EXP PRI EXP PRI

PRI EXP B PRI EXP B PRI EXP B PRI EXP B


# # # #
!

!
PRI EXP PRI EXP PRI EXP PRI EXP

DAE 6 DAE 10
!

!
!

!
DAE 1

!
!

!
EXP PRI EXP PRI EXP PRI EXP PRI
!

!
# A # A # A # A
EXP PRI EXP PRI EXP PRI EXP PRI

PRI EXP B PRI EXP B PRI EXP B PRI EXP B


# # # #
!

!
SYM-001701

PRI EXP PRI EXP PRI EXP PRI EXP

DAE 5 DAE 9
!

!
!

!
OFF

OFF

OFF
ON

ON

ON
O

O
I

I
NOTE: Table 2 on page 73 provides part number information about back-end cables.

66 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


PART NUMBERS
EMC CONFIDENTIAL

Main Components

Table 1 Main Components for VMAX and VMAX SE modela (Sheet 1 of 4)

Part
Name number Notes

#1 Engine cooling fan 045-00-204 Air mover module, 24 V input

#2 Power distribution unit (PDU) 100-885-137 A single part number for all power configurations

#3 Power distribution panel (PDP) 100-885-140 Three-phase WYE PDP

#4 Power distribution panel (PDP) 100-885-139 Three-phase DELTA PDP

#5 Power distribution panel (PDP) 100-885-138 Single-phase PDP

#6 DAE 100-885-345 Empty DAE chassis

#7 DAE link control card (LCC) 100-562-126


100-561-803

DAE power supply/cooling module 071-000-574 Dual +12V, hot-plug, 400W 1U


#8 071-000-567

#9 Engine power supply 071-000-561

#10 MIBE power supply/cooling module 071-000-521 Replaced from the front

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 69


EMC CONFIDENTIAL

Table 1 Main Components for VMAX and VMAX SE modela (Sheet 2 of 4)

Part
Name number Notes

Standby power supply (SPS) 078-000-050 FRU for 078-000-050 is 078-000-051


#11 078-000-086

#12 Front door USB AC adapter 071-000-521 Powers front door blue LED assembly in storage bays

#13 UPS 078-000-052 350W power supply for the Server, FRU is 078-00-053

#14 Server 090-000-208 Intel 1U server (Feidman)

091-000-091 Avocent (Ergo) KVM


#15 KVM
091-000-090 Belkin KVM

#16 Modem (optional) 100-602-106


2 GB Cache Memory Module 100-562-963 Serialized memory modules, replaced in pairs, used in Cache
#17 4 GB Cache Memory Module 100-562-965
100-562-948 Memory Module replacement kits.
8 GB Cache Memory Module

#18 MIBE assembly 100-886-914 MIBE without power supply/cooling module

#19 Management Module 103-049-000C

#20 System Interface Board (SIB) 303-301-100B

#21 I/O Module carrier 103-064-000B No hardware compression

70 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Table 1 Main Components for VMAX and VMAX SE modela (Sheet 3 of 4)

Part
Name number Notes

I/O Module carrier with


#22 103-099-000A Used only with GbE SRDF Front End I/O Modules
compression

#23 VMAX director 103-800-002C Director without Cache Memory Modules


Fibre Channel Back End I/O
#24 303-086-100B 4 Gb Fibre Channel 4-port SFP
Module
Fibre Channel Back End I/O
#25 303-176-100B 4 Gb Fibre Channel 4-port SFP with encryption
Module with encryption
Fibre Channel Front End I/O
#26 103-054-100C 4 Gb Fibre Channel 4-port SFP
Module

#27 FICON Front End I/O Module 303-085-100B 4 Gb FICON 2-port SFP
GbE iSCSI/SRDF Front End I/O
#28 303-950-100C 4 GbE iSCSI 2-port SFP
Module
GbE iSCSI/FCoE SRDF Front End
#29 303-142-100A 10 GbE iSCSI/FCoE 2-port SFP
I/O Module
Fibre Channel Front End I/O
#30 303-092-102B 8 Gb Fibre Channel 4-port SFP
Module

#31 FICON Front End I/O Module 303-120-100B 8 Gb FICON 2-port SFP

#32 SFP MM ports, 2/4 Gb 019-078-032

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 71


EMC CONFIDENTIAL

Table 1 Main Components for VMAX and VMAX SE modela (Sheet 4 of 4)

Part
Name number Notes

#33 SFP SM ports, 2/4 Gb 019-078-039

#34 SFP+ MM ports, 2/4/8 Gb 019-078-042

#35 SFP+ SM ports, 2/4/8 Gb 019-078-043

#36 SFP+ MM ports, 10 Gb 019-078-041 8 Gb GbE iSCSI/FCoE 2-port SFP

#37 VMAX SE front door light bar 039-003-711

#38 VMAX front door light bar 039-003-712

a. The most recent part information is available on MyGSIntranet, in the Parts Compatibility Database.

72 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Back-End Cables
Table 2 Back-end cables for VMAX and VMAX SE modelsa

Part
Name number Notes
QSFP to 4HDSSDC 038-003-706 Direct-connect cable, 4.5 meters/177.16 inches
QSFP to 4HDSSDC 038-003-708 Direct-connect cable, 2 meters/78.74 inches
HDSSDC to HDSSDC 038-003-510 Daisy-chain cable, 4 meters/157.48 inches
HDSSDC to HDSSDCb 038-003-572 Daisy-chain, separated storage bay cable,10 meters/393.7 inches

HDSSDC to HDSSDCc 038-003-508 Daisy-chain cable, VMAX SE expansion bay, 1 meter/39.37 inches

a. The most recent part information is available on MyGSIntranet, in the Parts Compatibility Database.
b. VMAX systems only
c. VMAX SE systems only

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 73


EMC CONFIDENTIAL

MIBE 3.125 GBPS QSFP Cables with Boss Backshell


Table 3 MIBE 3.125 GBPS QSFP cables for VMAX and VMAX SE modelsa (Sheet 1 of 2)

Name Part
number
Notes
31 inches/0.79 meters 038-003-694 Dir 12/SIB B to MIBE B port 3
Dir 11/SIB A to MIBE A port 2
Dir 11/SIB B to MIBE B port 2
Dir 12/SIB A to MIBE A port 3
34 inches/0.86 meters 038-003-695
Dir 13/SIB B to MIBE B port 4
Dir 14/SIB B to MIBE B port 5
Dir 16/SIB A to MIBE A port 7
41 inches/1.04 meters 038-003-696 Dir 9/SIB A to MIBE A port 0
Dir 5/SIB A to MIBE A port 12
52 inches/1.32 meters 038-003-697
Dir 6/SIB A to MIBE A port 13
Dir 6/SIB B to MIBE B port 13
60 inches/1.52 meters 038-003-698 Dir 7/SIB B to MIBE B port 14
Dir 8/SIB B to MIBE B port 15
Dir 3/SIB A to MIBE A port 10
68 inches/1.73 meters 038-003-699
Dir 5/SIB B to MIBE B port 12
Dir 7/SIB A to MIBE A port 14
Dir 8/SIB A to MIBE A port 15
46 inches/1.17 meters 038-003-700
Dir 15/SIB B to MIBE B port 6
Dir 16/SIB B to MIBE B port 7

74 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Table 3 MIBE 3.125 GBPS QSFP cables for VMAX and VMAX SE modelsa (Sheet 2 of 2)

Name Part
number
Notes
63 inches/1.6 meters 038-003-701 Dir 4/SIB A to MIBE A port 11
Dir 1/SIB A to MIBE A port 8
Dir 2/SIB A to MIBE A port 9
72 inches/1.83 meters 038-003-702
Dir 3/SIB B to MIBE B port 10
Dir 4/SIB B to MIBE B port 11
Dir 1/SIB B to MIBE B port 8
85 inches/2.16 meters 038-003-703
Dir 2/SIB B to MIBE B port 9
Dir 9/SIB B to MIBE B port 0b
Dir 10/SIB A to MIBE A port 1
Dir 10/SIB B to MIBE B port 1
Dir 13/SIB A to MIBE A port 4
Dir 14/SIB A to MIBE A port 5
39.37 inches /1 meter 038-003-704 Dir 15/SIB A to MIBE A port 6
Dir 7/SIB A to MIBE A port 14c
Dir 8/SIB A to MIBE A port 15
Dir 7/SIB B to MIBE B port 14
Dir 8/SIB B to MIBE B port 15

a. The most recent part informatin is available on MyGSIntranet, in the Parts Compatibility Database.
b. VMAX systems only
c. VMAX SE systems only

EMC Symmetrix VMAX Series Customer Service Quick Reference Guide 75


EMC CONFIDENTIAL

RS-232 Sense Cables


Table 4 RS-232 Sense Cables for VMAX and VMAX SE modelsa

Part
RS-232 cable type number Notes
MIBE to MIBE 038-003-594

System bay SPS to Management Module 038-003-623 19 inches/0.48 meters

System bay SPS to Management Module 038-003-682 12 inches/0.30 meters

a. The most recent part informatin is available on MyGSIntranet, in the Parts Compatibility Database.

76 EMC Symmetrix VMAX Series Customer Service Quick Reference Guide