SOP VHMS Controller Replacemnent

1. The document outlines the standard operating procedure to replace a VHMS controller. It involves downloading settings from the old controller, installing the new controller, and uploading the saved settings to the new controller. 2. Key steps include preparing a checklist, downloading settings from the old controller using software, saving the settings, removing the old controller, installing the new controller, uploading the saved settings to the new controller, and verifying the download. 3. Troubleshooting tips are provided for issues like error messages or finding the correct communication port.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views4 pages

SOP VHMS Controller Replacemnent

1. The document outlines the standard operating procedure to replace a VHMS controller. It involves downloading settings from the old controller, installing the new controller, and uploading the saved settings to the new controller. 2. Key steps include preparing a checklist, downloading settings from the old controller using software, saving the settings, removing the old controller, installing the new controller, uploading the saved settings to the new controller, and verifying the download. 3. Troubleshooting tips are provided for issues like error messages or finding the correct communication port.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Standard Operating Procedure to replace VHMS controller

A. Procedure overview 1. Install new controller


2.UPLOAD old controller setting
1. Conduct download 3. Conduct download and check
2.Save the old controller setting content
3. Remove the old controller

Old VHMS controller New VHMS controller

B. SOP Basic step SUMMARY


1. Prepare check sheet
2. Turn on engine key
3. Conduct down load by VHMS technical analysis tool box software ver 3.04.009
5. Close the VHMS technical analysis tool box software ver 3.04.009
5. Start the VHMS Setting Tool ver 3.5.1.0 and save the setting of the old controller
6. Close the VHMS Setting Tool ver 3.5.1.0 and turn off the engine key

7. Remove Old VHMS Controller


8. Install new VHMS Controller

9. Turn on engine key


10. Start the VHMS Setting Tool ver 3.5.1.0 and UPLOAD the setting of the old controller to the NEW Controller

11. Conduct down load by VHMS technical analysis tool box software ver 3.04.009
12. Check the down load content is correct to machine data (S/N, last SMR, engine S/N)
13. Turn off engine key and close all VHMS software
14. Fill in the check sheet and send it to UT HO Service TO

C. Detail steps
1. Prepare check sheet
2. Turn key on
3. Conduct down load by VHMS technical analysis tool box software ver 3.04.009

4. Check the down load content whether it is correct to machine data (S/N, last SMR, engine S/N)

5. Start the VHMS Setting Tool ver 3.5.1.0 and save the setting of the old controller

Double click Click Next


VHMS Setting Tool ver 3.5.1.0

Choose 2nd option Save setting of old Controller Click Yes


"when VHMS needs to be replaced" Click Next
Click Next
Page 1/4
Click save Click OK and Exit

6. Close VHMS software or Turn on the engine key. Failure to do this may cause software not functionning properly

7. Remove Old VHMS Controller


8. Install New VHMS Controller

9. Turn off the engine key


10.Start the VHMS Setting Tool ver 3.5.1.0 and UPLOAD the setting of the OLD Controller to the NEW Controller

Click Next
VHMS Setting Tool ver 3.5.1.0

Choose 2nd option Click Next Click Next


"When VHMS needs to be replaced"
Click Next

Fill date and time


For Kalimantan
Time zone = GMT + 8
Date = actual date Content should be "OK"
Time = actual time in Kalimantan

Click OK and exit


Page 2/4
11. Conduct down load by VHMS technical analysis tool box software ver 3.04.009

12. Check the down load content whether it is correct to machine data (S/N, last SMR, engine S/N)
by opening a down load file (example trend.csv or tm_trend.csv or fault0.csv)
Example from trend.csv file
Should be correct:
Machine model
Machine Serial Number
Machine SMR
Engine Serial Number

SMR should be present at this location

13. If OK then close all VHMS software and turn off the engine key
14. Complete the check sheet and send it to UT HO Service TO

D. Remarks & Trouble shooting


1. In some case the following display may appears. Please click "OK" or click "enter" key and continue

2. If those displays result are encountered (in VHMS Setting tools ver 3.5.1.0) then

OR
OR

Close all VHMS software, restart the computer and start the process all over again

Page 3/4
3. When conducting down load, you cannot find the right communication port (COM1, COM2, COM3 etc) then

Close all VHMS software, restart the computer and start the process all over again Page 4/4