Bomba 6nhta Eb 1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

P R O D U C T D A T A S H E E T

CORNELL PUMP COMPANY


Model 6NHTA-EM Redi-Prime®

PUMP SPECIFICATIONS
• Size: 6NHTA - 6" discharge x 8" suction with
125# cast iron flanges.
• Casing: Cast Iron.
• Impeller: Enclosed - 2 vane. Handles 3"
diameter solids.
• Wear Rings: Replaceable. (Double wear rings
available).
• Seal: Cornell’s patented Cycloseal® design with
Run-Dry oil lubrication system. John Crane T-2
single mechanical seal with Viton® elastomers,
stainless steel hardware and tungsten- vs. silicon-
carbide seal faces for abrasion resistance.
• Check Valve: SwingFlex® Val-Matic®.
• Shaft Sleeve: Heat treated 416 stainless steel.
• Bearings: Heavy duty, grease lubricated, deep
groove ball bearings, with a minimum of 50,000
hours bearing life.
• Hardware: Stainless steel float linkage. A positive
seating vacuum priming valve prevents water
carry-over to the vacuum, pump or atmosphere.
• Vacuum Pump - 50 SCFM Maximum.

VACUUM PUMP DISCHARGE CHECK VOLUTE


VALVE DISCHARGE

AIR/WATER
SEPARATOR

BALL VALVE
SUCTION

BEARINGS SUCTION SPOOL


WEAR RING

BEARING FRAME BACKPLATE


IMPELLER
PUMP DIMENSIONS
C XA X DA
MIN. CLEAR.

OB OA
125#
KEYWAY FLANGE

U
DD
R MIN. CLEAR.
V 125# FLANGE

T Y YA AR
CP

NOTES: 1. "V" Dimension is minimum useable shaft. 3. Do not use for construction unless certified.
2. Flange connection dimension can vary ± .12 inch.

PUMP DIMENSIONS
CONNECTION
MODEL FRAME DISCH. SUCT. AR C CP DA DD OA OB R S T U V X XA Y YA KEYWAY
EM16 6 8 8 26.97 46.38 13.62 13.25 25.5 24.38 14.42 1 4.41 2 2.5 18.56 15 5 16.36 .50 x .25
6NHTA
EM18DB 6 8 8 27.97 47.38 13.62 13.25 25.5 24.38 14.42 1 4.41 2.5 2.5 18.56 15 5 16.36 .62 x .31

PERFORMANCE CURVES

Speed Impeller Dia. Style Solids Dia. NS Suction Discharge No. vanes
Feet x .305 = Meters
Inches x 25.4 = Millimeters 14"
GPM x .227 = Cubic Meters/Hour
VARIOUS ENCLOSED 3" 2120 8" 6" 2
GPM x 3.785 = Liters/Minute
HP x .746 = KW
SINGLE VOLUTE MOUNTING CONFIG.: F, EM
300 200
FEET
METERS

0R Data shown is approximate pump performance


PM at Sea Level with 60 deg. Fahrenheit water.
275
Total Suction Lift is equal to Static (vertical)
80 Suction Lift plus all Friction Losses in the suction line.
250
180 75 Efficiency shown is pump hydraulic efficiency.
0R For NPSHR, refer to standard pump curve.
PM
70 80
225
82
60 200
160
0R 83
not include discharge check valve losses.

TOTAL DYNAMIC HEAD

PM
vacuum pump. Performance curve does

83
Add 1.5 HP for belt driven diaphragm

175
50 82
150 1400 80
R PM
40
125

30 100
125 HP
75
20 100 HP

50 75 HP
frame mounted configuration with Cycloseal. R
Other liquids or mounting configurations may

10 50 HP
Performances shown are for cool water,

25
require performance adjustments.

TOTAL SUCTION LIFT 25 FT 20 FT 15 FT 10 FT


0
0 400 800 1200 1600 2000 2400 2800 3200
U.S. GALLONS PER MINUTE
CAPACITY
100 200 300 400 500 600 700

CUBIC METERS PER HOUR

6/17/02

Cornell Pump Company


P.O. Box 6334 • Portland, Oregon 97228-6334
Web: www.cornellpump.com • Phone (503) 653-0330 • Fax (503) 653-0338

You might also like