Product Information
Automation products, easy500, 700, 800 Control Relays
system solutions and
services. The recognised MFD-Titan® Multi-Function Display
brand name all around
the PLC, enhancing the
performance of machines
and systems.
PC based HMI-PLC
and PLC
Embedded HMI-PLC
Modular PLC
Compact PLC
HMI
Remote I/O
Operator- and
control relays Think future. Switch to green.
ºC
easy control relays provide many basic functions that users could previously only
implement with conventional devices that were individually installed and wired. In
addition to this, the MFD-Titan multi-function display offers powerful visualization
functions as well.
Thanks to the extensive range of the device series you are I/O with local and remote expansion modules and graphic
always sure of finding the right device for your specific visualization. The demand for user-friendly operation and
requirements. This range extends from the compact stand-alone programming is consistently met and forms the basis of the
control relay with a few timing relays and a time switch to large- outstanding features of easy and MFD-Titan, with particular
scale networked applications, processing several hundreds of importance being placed on simple circuit diagram input.
Simplicity as a concept
The easy and MFD-Titan device series stands out with its user-friendly operation and
programming, with particular importance being placed on simple circuit diagram
input. Every rung or circuit connection is wired in the same way as it was taught in
schools and colleges: Contact – Contact – Contact – Coil; Done! The devices allow
the “wiring” of 128 or 256 rungs or circuit connections for this purpose. Series and
parallel connections, which normally make up the major part of a control circuit, can
be created easily without any particular programming knowledge. Ready-to-use
function blocks that are simply integrated in the wiring with coils and contacts are
also provided for additional functions.
Everything on board
Depending on the device selected, easy and MFD-Titan devices can provide users
with timing relays, flash relays, counters, comparators, time switches and many other
ready-to-use function blocks, right up to powerful PID controllers. The circuit
diagram display of series and parallel connections, unlike the display of AND and OR
operations in FBD, offers the user a considerably more manageable display of the
circuit. Every easy control relay and MFD-Titan features an integrated power flow
display that ensures the safe operation of the circuit diagram during commissioning
and helps to identify errors in the circuit diagram initially created. This clearly
highlights every energized rung and dims those which are not energized.
The finished circuit diagram is stored internally (retentively) and can also be saved
externally on a memory module (EEPROM) together with all set parameters, for
transport, security and backup. A multi-level password protection secures your circuit
diagram against unauthorised viewing, editing, copying or deleting as required. easy
or MFD-Titan offer menu-driven interactive operation which can be carried out in
ten different languages. The very large operating temperature range from -25 to
+55°C for all easy and MFD-Titan control relays means that the devices can be run in
a wide range of machines and systems.
For controlling small applications with For controlling medium-sized applica- For controlling large-scale applications
up to 12 input/output signals tions with up to 40 input/output signals with up to 300 input/output signals
2/2 high-speed inputs, 1 kHz 2/2 high-speed inputs, 1 kHz 4 high-speed inputs, 3/5 kHz
(only DC devices) (only DC devices) (only DC devices)
MFD-Titan multi-function display easy800 control relay and MFD-Titan MFD-Titan multi-function display
For controlling large-scale applications The easy800 control relay and MFD- The MFD-Titan supports all the
with powerful visualization functions Titan combine virtually all the features functions of the easy800 and also
of a PLC with the user-friendly provides a fully graphical display. It
12 digital inputs operating features of the well-known replaces 7 segment displays and can
Easy product line. Thanks to their indicate fault messages and operating
integrated networking capability for up steps graphically or in plain text. The
4 digital relay outputs to eight devices, applications with over function buttons on the MFD-Titan can
or optionally 300 I/O points can be implemented. The be used for displaying and modifying
control system can be designed either setpoints during operation. High-speed
4 transistor outputs using a single local program or using signal counting, frequency
several programs on the different measurement, incremental encoder
distributed devices. Up to 1000 metres processing can all be implemented with
256 rungs of 4 contacts can be covered by the network. The easy800 and MFD-Titan without any
and 1 coil each control relays can also be integrated problems. Maths functions, data
easily in higher-level automation storage or communication via the NET
24 KB mask memory on a networks thanks to the networking network – all simply easy.
fully graphical, backlit modules available (for PROFIBUS DP,
display (64 x 132 pixels)
CANopen, DeviceNet, AS-Interface).
4 analog inputs (10-bit) MFD-AC-CP8 and MFD-AC-R16
optional (not with 230 V AC)
A new addition to the MFD-Titan
4 high-speed inputs, 3/5 kHz family! The MFD-AC-CP8 power supply
(only DC devices) and CPU modules now also provide
users with 230 V AC versions for their
1 digital expansion or applications. As with the already known
network connection 24 V DC version, a power supply/CPU
module is available without easy-NET
Networkable via easy-NET (MFD-AC-CP8-ME) and with easy-NET
with up to 8 stations (MFD-AC-CP8-NT). If users also require
230 V AC inputs for their MFD-Titan
1 analog input (10 bit) applications, Moeller can now offer the
MFD-AC-R16 I/O module in
combination with the two MFD-AC-CP8
power supply/CPU modules. This
therefore provides 12 inputs and 4 relay
outputs.
Station 3
Service
required Station 3
Motor 1
fuse
MFD-Titan
1 2b 3
the HMI-Control
When fitted with a power supply/CPU
module and optional input/output
modules, the display can also be
expanded into a compact HMI control
device that then combines the complete
functionality of an easy800 with
powerful visualization functions. The
two modules are simply plugged
together. Plug & work
1 2 3
X
X
C
C
RC
-R
-R
RC
RC
-R
-R
-R
03 AC
08 DC
Type
06 A
07 A-
01 B
02 B-
04 C
05 C-
41 2-A
41 2-A
41 2-D
41 -A
41 -A
41 -D
41 2-
41 2-
Order No.
27 Y51
27 Y51
27 512
27 512
27 512
27 51
27 51
27 51
SY
SY
SY
SY
SY
S
S
SY
EA
EA
EA
EA
EA
EA
EA
EA
EA
Supply voltage 24 V AC 100 - 240 V AC 12 V DC
Heat dissipation 5 VA 5 VA 2W
Inputs, digital 8 8 8 8 8 8 8 8
Outputs, analog 0 - 10 V - - - - - - - -
LCD display / keypad Yes / Yes -/- Yes / Yes Yes / Yes -/- Yes / Yes -/- Yes / Yes Y
7-day / year time switch Yes / Yes Yes / Yes -/- Yes / Yes Yes / Yes Yes / Yes Yes / Yes -/- Y
Short-circuit proof with power factor 0.7... 0.7 Line protection B16, 900 A
Degree of protection IP 20
Dimensions (W x H x D) mm 71.5 x 90 x 58 mm
[1] Relay = 8 A (10 A to UL) with resistive load, 3 A with inductive load/transistor outputs = 0.5 A / 24 V DC, max 4 outputs switchable in parallel
[2] With backlight in continuous operation - 10 °C ... 0 °C
[3] In stand-alone operation the MFD-...CP8-... CPU slices can also be mounted on a DIN 50022 top-hat rail, 35 mm or as screw mounting with ZB4-101-GF1 fixing brackets
X
X
X
X
C
C
C
C
RC
RC
RC
RC
RC
TC
-R
-R
-R
-R
-R
-T
-T
17 A
18 A-
11 C
12 C-
21 C
09 C
10 C-
13 B
14 B-
15 C
16 C-
19 C
20 C-
41 2-D
41 1-D
41 2-D
41 9-A
41 9-A
41 9-D
41 9-D
41 -D
41 -D
41 -A
41 -A
41 -D
41 -D
27 512
27 512
27 719
27 719
27 719
27 719
27 51
27 72
27 51
27 71
27 71
27 71
27 71
SY
SY
Y
SY
SY
SY
SY
SY
SY
SY
SY
SY
SY
AS
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
24 V DC 24 V AC 100 - 240 V AC 12 V DC 24 V DC
2W 7 VA 10 VA 3.5 W 3.5 W
8 8 8 8 12 12 12 12 12 12 12 12 12
2 2 2 2 4 4 - - 4 4 4 4 4
4R 4R 4T 4T 6R 6R 6R 6R 6R 6R 6R 6R 8T
- - - - - - - - - - - - -
Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes
Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes
IP 20
- 25 °C ... + 55 °C
- 40 °C ... + 70 °C
107.5 x 90 x 58 mm
X
X
X
C
C
C
C
RC
RC
RC
TC
TC
TC
-R
-R
-R
-T
-T
22 C-
73 C
74 C-
75 C
76 C-
67 C
68 C-
69 C
70 C-
71 C
72 C-
50 0
62 1-D
62 2-D
62 9-A
62 9-D
62 0-D
52 -8
41 -D
62 -D
62 -D
62 -A
62 -D
62 -D
26 FD
27 721
25 821
25 822
25 819
25 819
25 820
25 82
25 82
25 81
25 81
25 82
M
SY
SY
SY
SY
SY
M
SY
SY
SY
SY
SY
SY
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
10 VA 3.4 W 3W
12 12 12 12 12 12 12 12 12 12 12 -
4 - - 4 4 4 4 4 4 4 4 -
8T 6R 6R 6R 6R 6R 6R 8T 8T 8T 8T -
- - - - - 1 1 - - 1 1 -
-/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / - Ye
Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes -/-
IP 20 IP 65
Clearly legible
- 25 °C ... + 55 °C
- 5 °C ...+ 50 °C
- 40 °C ... + 70 °C
T
-M
-N
00
00
6
T
64 -M
64 17
56 17
93 -R1
53 -N
51 -B
92 P8
54 16
55 16
91 P8
94 -5
95 -8
53 RA
52 -80
52 P8
52 TA
71 P8
40 P4
40 P4
40 -C
52 -R
52 -T
40 -C
40 C
27 D-A
26 D-C
26 FD-
26 D-C
27 -AC
26 FD
26 FD
26 FD-
27 D-C
27 D-C
27 -AC
26 FD
M
M
M
M
F
M
F
FD
F
FD
M
M
M
M
M
M
1.5 W 3W 8 VA 0.5 W
- - - - - - - 12 12 12 12 12
- - - - - - - - 4 4 4 4
- - - - - - - 4R 4R 4R 4T 4T
- - - - - - - - - 1 - 1
es / Yes -/- -/- -/- -/- -/- -/- -/- -/- -/- -/- -/-
-/- -/- -/- Yes / Yes Yes / Yes Yes / Yes Yes / Yes -/- -/- -/- -/- -/-
- - - - - - - 8A 8A 8A 0.5 A 0.5 A
IP 20
e at
- 25 °C ... + 55 °C
C [2]
- 40 °C ... + 70 °C
EASY-SOFT offers the following display The finished program is stored for ever
formats for viewing, editing and in easy's non-volatile memory or until it
printing out your program: is modified. Additional auxiliary power
or a battery are not required. The
IEC format with contact and coil control relays are thus entirely
symbols of the international standard maintenance-free.
easy circuit diagram, a 1:1
representation of the display in easy Not only circuit diagrams and
parameters are saved in the event of a
ANSI format, in compliance with the
power failure. easy also makes a note of
American standard
switch positions or values. For example,
the actual values of operating hours
EASY-SOFT supports you in meters, counters and timing relays can
configuring, programming and be processed further once power is
defining parameters for easy control restored. The retentive function for the
relays, and in creating visualization different function blocks and data is
functions for the MFD-Titan. If control available with all performance classes of
relays are connected to easy-NET, all the easy series.
connected devices can be accessed and
their programs loaded from a single
control relay.
Y
14 -R
12 -R
13 -T
P
86 RE
15 S
23 4-D
23 -EA
23 DC
23 AC
21 DC
Type
21 2-
21 20-
21 18-
23 18-
23 Y20
21 20
21 200
16
Order No.
SY
6
6
6
S
SY
SY
SY
SY
EA
EA
EA
EA
EA
EA
Heat dissipation 1W 10 VA 4W 1W 2W
Inputs, digital - 12 12 12 - -
Outputs, analog 0 - 10 V - - - - - -
Short-circuit proof with power factor 0.7... 0.7 Line protection B16, 900 A - - -
2
0.2 - 4.0 mm (AWG 22-12), solid 0.2 - 4
Connection cables
0.2 - 2.5 mm2 (AWG 22-12), flexible 0.2 - 2.
Degree of protection IP 20
[1] Relay = 8 A (10 A to UL) with resistive load, 3 A with inductive load/transistor outputs = 0.5 A / 24 V DC, max 4 outputs switchable in parallel
Application
24 W
19 W
98 SI
40 N
39 O
94 -PO
23 -PO
35 2-D
15 5-A
35 1-C
22 00
21 00
23 22
23 22
22 20
4
SY
SY
SY
SY
SY
EA
EA
EA
EA
EA
Yes, SELV
- - - Potential isolation (prim./sec.)
(to EN 600950, VDE 805)
- - -
Additional output
- - - Others -
voltage 12 DC, 20 mA
- - -
2
4.0 mm (AWG 22-12), solid 0.2 - 4.0 mm2 (AWG 22-12), solid
Connection cables
5 mm2 (AWG 22-12), flexible 0.2 - 2.5 mm2 (AWG 22-12), flexible
IP 20 Degree of protection IP 20
178, IEC/EN 60947, UL, CSA Certification, standards EN 50178, IEC/EN 60947, UL, CSA
Wema Probst, based in Freigericht, The Wema Probst automation concept relay passes on status changes
Germany, uses the power of MFD-Titan requires that every system section is automatically to the network. For
and easy800 for the control of its new equipped with its own stand-alone example, in order to process input 1 of
profiling system. Moeller's multi- control system. When supplying a station 5 in the program of station 3,
function display provides networking complete system, the individual control you just have to place the station
already on board, from which not only systems should then be networked to address in front of the operand
the machine builders but also their end control the entire system. The system designation (I for input), i.e. 5 I1. Even
customers can benefit. The machines should then be operated and monitored user-friendly function blocks are also
and systems from Wema Probst are from a central control panel. “We can’t available for sending and receiving
designed for the field of small timber and must not develop new system entire data areas.
processing. controls for each customer.
F1
L1
N
H1 H2 H3
F1
L1 S0 Emergency-stop
N
Band 1 S1 START pushbutton actuator
S0 S1 S2 S3 Q1 Q2 Q3
S2 STOP pushbutton actuator
S3 Quick STOP pushbutton actuator
Band 2 L N N I1 I2 I3 I4 I5 I6 I7 I8 Q1 - Q3 Trip-indicating auxiliary contacts for
DEL ALT
1 0 motor 1 – 3
K1 - K3 Motor for belt 1 – 3
easy 512-AC-R ESC OK
1 2 1 2 1 2 1 2
H1 Indicator light
Q1 Q2 Q3 Q4
Band 3
F1 miniature circuit-breaker,
K1 K2 K3 H1
16 A, Char. B
Task definition 5 seconds between the pressing of the The belts upstream of the failed drive
pushbutton actuator and the switching should be switched off immediately.
Three conveyor belts are to start up and off of belt 1. The subsequent belts
run down at staggered intervals. There should then likewise switch off after 5
are three operating modes: “Staggered seconds. It should be possible to modify Benefits
Startup”, “Staggered Run Down”, and the time via the “easy” control relay; for
“Quick Stop”. The motor-protective this purpose, the “+” must be set in the Implemented functions:
circuit-breakers of the belt drives are function block programming. The 2 x timing relays, on-delayed
monitored; in the event of tripping, a “Quick Stop” pushbutton actuator S3 List price approx. 70 ¤
controlled stop is initiated on the should switch off all three belts without 2 x timing relays, off-delayed
conveyor system. The cause of the fault a time delay. List price approx. 120 ¤
should also be reported by means of a 1 x flash relay
flashing light. Motor failure: List price approx. 60 ¤
The trip-indicating auxiliary contact 2 x contactor relays
(PKZ) should open in the event of a List price approx. 40 ¤
Function description motor failure. The fault is indicated with Less wiring required
a flashing light and should cause the
Less space required compared to
The three conveyor belts for a bulk automatic initiation of the STOP
conventional solution
material conveyor system are to start up procedure. This means that in the event
and run down with staggered times in of a fault, the belts downstream of the Password function for protection
order to ensure safe and trouble-free failed drive should be run empty for 5 against unauthorised access
material transport. seconds and then switched off.
Startup:
This is initiated by the S1 START Load current circuit
pushbutton actuator. The belts start up L1
L2
at fixed time intervals of five seconds L3
each. Belt 3 starts up first. N
PE
Switch off: Q1 Q2 Q3
M1 M2 M3
B1 Pressure sensor
L1 F1 Miniature circuit-breaker, 16 A, Char. B
N
PE
F2 Miniature circuit-breaker (optional)
F1
S1 S2 Q1 Q2 S3 P G1 Power supply unit 230 V AC/24 V DC
B1
0-10V
G1 ~ H1 Indicator light for pump 1
- F2
S0 H2 Indicator light for pump 2
+24V 0V
+24V0V 0V I1 I2 I3 I4 I5 I6 I7 I8 K1 Contactor for pump P1
DEL ALT
Task definition switch to new comparison values time T5 has elapsed by the alternate
according to the following equation: flashing of H1 and H2. It must be
Two pumps provide the water supply Required changeover time in hours possible to enter the limit value for low
to a system. Their function is to be x 60 = Comparison value pressure on the “easy”.
monitored. The two pumps are to Preset:
operate alternately in order to save 48 hours x 60 = 2880 Acknowledgement:
wear. System operating states and faults All fault messages shall be indicated
are to be signalled by means of two Faults: until they are acknowledged via
indicator lights. It must be possible to The failure of a pump motor is detected pushbutton actuator S3.
set the pressure-dependent switching by means of the trip-indicating auxiliary
points as required for activating the contact of motor-protective circuit- Maintenance:
pumps. breaker Q1 and Q2. The pump that is It must be possible to switch pump P1
still functional is activated. If a pump is directly using keyswitch S1 and pump
faulty, the resulting low pressure should P2 using keyswitch S2.
Function description be detected. The other pump should be
activated after time T4 has elapsed.
Pump operation: Both types of faults are indicated by Benefits
The pump station provides the water means of the corresponding H1 and H2
supply to a system. In this process, the indicator lights. Implemented functions:
pressure should not go below a 1 x flash relay
specified minimum pressure. The two Low pressure: List price approx. 60 ¤
booster pumps P1 and P2 are provided The system is monitored for low 2 x timing relays, on-delayed
and, in the event of low pressure, one pressure. Low pressure is indicated after List price approx. 70 ¤
of them is activated by means of 1 x operating hours counter
pressure sensor B1. In order to maintain Pressure value processing (analog
an even utilisation and wearing of the value)
Load current circuit
pumps, they are run alternately every
Variable switching points
forty-eight hours. The two indicator L1
L2 and operating hours changeover
lights H1 and H2 are used to indicate L3
N
Xtra Combinations
It provides:
■ flexibility and simplicity
■ great system availability
■ the highest level of safety