; i
efrigeration
Industrial processes
il & gas(Gi) K-FLex
Closed Cell Products
Thermal insulating closed cell products have many advantages over the traditional
‘pen cell and products mace of wool or fibreglass:
~ They have a better thermal conductivity, because the ar inside the closed cells has
‘a lower mobilty than that produced in open cells therefore the convective compo-
rent of heat exchange is considerably lower.
Vapour dtfusion into the insulation is much lower, thus the thermal conductivity wil
be guaranteed for longer, even without using protective coatings,
~The mechanical properties are better.
= They promote a natural inhibition of bacterial growth, because bacteria cannot
spread within the structure
Resistant to water vapour diffusion (u factor)
Our materials are resistant to water vapour diffusion. The higher the resistance to
the penetration of water vapour, (denoted by Mu (jj), the greater theconsistency
of performance over a period of time, This benefits significant when insulating
Ccold items, where insulation thicknesses are chosen so as to achieve a surface
temperature above the ambient dewpoint. Ambiont humicity will ry to breach the
insulation in order to achieve equilibrium conditions. Because the thermal conduc~
tivity of water is 0,58 W / (mK), and therefore about 16 times higher than our insu-
lation, any absorption of water vapour could reciuce the insulation efficiency, The
formation of condensation on the surface of tubing and ducting is the main cause
of conosion beneath insulation which quickly leads to damage of pipes and ducts.
Many insulation materials are porous or fibrous. In these types of materials the
presence of moisture and organic matter alow the growth of bacteria, mould and
fungi, Our products are resistant to this and thus contribute to the quality of the air
that we breathe. We do our best to ensure that our products do not emit VOCs
{volatile organic compounds) to further protect ar quality by changing the ingredients
and production process and ensuring that the products are from certified suppliers.
In the USA our products are certfied GREENGUARD by the AQS (Air Quality Science)
Laboratories. This prestigious qualifcation in the "GREENGUARD for Children &
Schools" programme ensures that the product does not emit toxic substances. In
Europe there is a similar certification ‘rom the German insttute EPA which has
approved our product as completely harmless with regard to the emission of ait-
borne substances, Elastomenc insulation isnot made of fibrous material, and
does not release harmful particles into the air. Thistheretore, is regarded as an ideal
product for use in publi places such as schools and hospitals It is also used in clean
rooms: forthe production of microcnips where the minimum of dust and the absence of
pollutants are a necessity for efficent production processes.
Fire Behaviour
‘Al our products are cetiied and supervised at major international laboratories wich
guarantee that they are self-extinguishing in case of fre. Years of experience and in-
ternational presence have allowed us to surpass even the strictest standards: BS 476,
DIN 4102, Euroclass, Italian Class 1, Spanish M1, French NF-FEU, American ASTM and
these are just some of over 1500 certications that our materials have achieved,K-FLEX ST
K-FLEX ST
Elastomeric insulation K-FLEX ST is suitable for all applications both
for all applications, civil and industrial that require the use of insulation
both civil and industrial. material, providing a good quality product and value
for money: refrigeration, air-conditioning, heating and
plumbing, tanks, pipe fittings and water ducts
Applications:
Air-conditioning
Refrigeration + Light weight and flexible for easy and_s
installation with low mainter
+ Wide range of tube and sheet with self adhe:
aluminium foil available.
Industrial processes
Oil & gasCopper pipe Ironpipe 9-3/8" 13+ 1/2" 1945/4" 5+" BRe L-H/A" 4+ 1-1/2" 5042
ie KODE UE OE Oe a a a a a
ae aE ae st ant taste 080 sto _ss10
se se a as ani teat sets ts tg a
Ww ae ae aia isi gt oe
Si ne BE wa se Sin tes sv as ase
ie ae ar as sa3§ teas apna as ag ae
ie a ae Lae se sn tsi ss at aaa
iam Tay tse sna tsa sua nts tts
zie Ee ust ss tease isnt ase se as
2a La” Fw as sist tsa ane xeo geo
2 Le oS ner sagt tsar sng ae?) ase?) ae
* as ain wn sin as a
2 a BE ar a i a sae aan — ae — aa
a o300 saw tea saan ano a
= ania test sven xt ast a
“Ts sais testes savas xt
= ae in — ice an ae ae
“ea ani test x80 gas aim ato
= ew sai testes sates inter ats aes
Sat aches Sheste.
snes
PRO
aro
Pun
Sao
Pus
aro —
Puno
aos
Worldwide Leader
in the production
of Elastomeric Insulation
for Energy SavingK-Flex ST tubes & Sheet
Temperature range
‘Thermal conductivity A. W/m.K)
EN 12667 (DIN 52612) ENISO 8497 (OIN 52613)
Permeability
EN 12086 (DIN 2615)
Water absorption rate
ASTM C209
Dimension Stability GP 8811-88
Corrosion problem
Noise Reduction (DIN 4109)
Fire
BS 476 pan 6&7
GB 8624
EN 13501-
‘Smoke Visibility ISO 5659
‘Smoke Toxicity
Fungal Resistance
Bacterial Resistance
‘@wp ODP.
Dust and Fiber
VOC Emissions