Sample Layout1

The document proposes a plot layout and provides calculations for the floor area ratio (FAR) of a building on the plot. It lists the occupancy type as A-2, total land area as 1063.94 sqm, and deducted land areas for calculations. It then calculates the net land area, required and existing road widths, and shows the basic FAR is 5.00. It provides a table comparing the allowable total floor area based on these calculations against the proposed floor area of 4627.23 sqm.

Uploaded by

Md Suruzzaman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views1 page

Sample Layout1

The document proposes a plot layout and provides calculations for the floor area ratio (FAR) of a building on the plot. It lists the occupancy type as A-2, total land area as 1063.94 sqm, and deducted land areas for calculations. It then calculates the net land area, required and existing road widths, and shows the basic FAR is 5.00. It provides a table comparing the allowable total floor area based on these calculations against the proposed floor area of 4627.23 sqm.

Uploaded by

Md Suruzzaman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PROPOSED PLOT

123

124

CALCULATION of FAR
23
28
* Occupancy Type = A-2
22 21 * Total Land area = 1063.94 sqm.
29 * Deducted Land Area = at North Side 5.03X2.28=11.47
= at East Side (20.5+2.6+18.89)X1.37=57.53 sqm
30
* Net Land Area = 994.94 sqm
* Required Road Width = 9.14 m & 3.66 m
19 20 * Existing Road width = Front 5.64m, Side 0.86m , 1.57m & 1.70m
* Basic FAR = 5.00

Allowable value Proposed value


Total Floor area 994.94x5.0=4974.7 sqm
4627.23 sqm
(Without any Exemption)

Ground coverage 522.34 sqm.(52.5% of land area) 522.32 sqm


(52.5% of land area)
Car parking 1 Car for every 2 units
(for flats of gross area from 90 to 140 sqm)
7247 so minimum car nos=1/2 of 26=13 nos
39 nos
1 Cars for every 4 units
(for flats of gross area from 60 to 90 sqm)
RS MOUZA MAP so minimum car nos=1/4 of 26= 6.5 = 7 nos
Scale= 1:4000
RS Plot No: Motor Bike parking 1 Bike for every 5 units
Holding No: MS MOUZA MAP (for flats of gross area upto 90 sqm) 10 nos
so minimum Bike nos=1/5 of 26= 5.2 = 6 nos
Scale= 1:4000
MS Plot No: Green area Minimum 236.30 sqm 243.87 sqm
Holding No: (23.75% of land area) (24.51% of land area)
Hanging verandah
Maximum 6.0 sqm
over ground floor at (30% of 20.00 m or building length at North side) 4.92 sqm
North side ROAD

Hanging verandah over


ground floor at Maximum 13.35 sqm 13.29 sqm
East side ROAD (30% of 44.51m or building length at East side)

Hanging verandah over Maximum 12.66 sqm

250 m Radius ground floor other


than ROAD side
(2.5% of per floor area) 2.04 sqm

Circle Community Space


Minimum 156.19 sqm
4% of 3904.65 sqm (Apartmant area without lift,stair,lobby, and
veranda)
156.50 sqm

*APARTMENT UNIT AREA

MAIN ROAD A= 94.67 sqm --- 9 nos


B= 91.79 sqm --- 9 nos
C= 87.99 sqm --- 9 nos
D= 87.99 sqm --- 9 nos
DUSTBIN E= 87.23 sqm --- 8 nos
F= 90.86 sqm --- 8 nos
Total=540.53 sqm ---52 nos

Floor area within Sub-total area


Floors Area Beyond FAR(sqm)
FAR(sqm) per floor(sqm)

Parking 647.53
Basement floor Stair = 7.34
Driver's Waiting 8.27 683.12
4.57m WIDE ROAD P.P Semi Store = 6.23
Lift Pit 13.75
Cover Drain Semi Pucca
4.15m W

2 Std. Pucca Parking 605.02


4.27m

Semi Semi
P.P Pucca Bldg.
4 Std. Pucca P.P Lift, Stair & Lobby =48.61 Guard room 4.00
Semi 2 Std. 6 Std. Bldg. Ground floor 689.13
Semi Electrical Room
W

Pucca Semi Semi Bldg. Bldg. 4 Std. 17.84


Semi 3 Std.
IDE RO

Pucca Pucca Semi 6 Std. Pucca Bldg.


IDE ROA

Pucca Semi 2 Std. Fire Stair 13.66


Bldg.
3.35m W

Pucca Bldg.
Pucca Bldg.
P.P Semi Community = 156.46 Front/North Verandah 3.16
7 Std. Pucca Apartment = 285.76
AD

Semi Lift= 13.66 East Road/Front Ver 11.62


IDE ROA

P.P 2 Std. 7 Std. Bldg. 540.53


Pucca 1st floor Stair= 11.80
5 Std. Bldg. Bldg. P.P Fire Stair 13.66
O P E N Bldg. 3 Std.
6 Std. Corridor & Lobby= 38.94
D

Semi 4 Std. Bldg. Front/North Verandah 4.92


D

3 Std. Bldg.
Pucca Bldg. Apartment = 435.53
Bldg. 6 Std.
GA
Semi 3 Std. Lift= 13.66 East Road/Front Ver 13.29
S
DCC DUSTBIN
5 Std. Pucca Bldg. Bldg. Stair= 11.80
Semi 6 Std. Semi Semi 540.53 GA
120m Far From Site
U/C
DC
Bldg.
S
P.P Side Ver (West) 2.04
C
2nd floor Corridor & Lobby= 45.63
Pucca Bldg. Pucca Pucca
P.P GA DC

>>>
EL
Fire Stair
S C
4 Std. 13.66
P.P P.P
Cover Drain
P.P Bldg. 4.92 D
A ± 0.0m
DC EL
4.27

P.P Front/North Verandah GAS C

P.P 6 Std. P.P 4 Std. Semi


4Bldg. Apartment = 435.53
Lift= 13.66 East Road/Front Ver 13.29 E RO EL
mW

Bldg.
W I D A D >>
GAS
P.P P.P Bldg. Pucca 12 Std. DC
Stair= 11.80 C
4 Std. 3rd floor 540.53 EL PP
5 Std. 4 Std. Bldg. Side Ver (West) 2.04
m
9.14 E R O
GA
IDE

Corridor & Lobby= 45.63 S


Bldg.
2 Std. Bldg. 25 4 Std.
U/C
Bldg. Fire Stair 13.66
E D D 5.0
6m
. DC FOR
ROA

0m I
C

Mosque P.P
Bldg.
IDE R
OAD P.P Semi O S W ARE ROAD
EL

m W P.P 9 Std. Front/North Verandah 4.92


O P 4.57m
AE WID
3 Std. 3.66 P.P Pucca
R
D

FFE E
Apartment = 435.53
EL
Semi P
3.35

Bldg. CTE N
G
<<< STIN
OPEN P.P
m
4.27m

Bldg. Lift= 13.66 East Road/Front Ver 13.29 GAS D


Pucca
250
Semi 4 Bldg.
mW

6 Bldg. 7 Std. 4th floor Stair= 11.80


OAD
DC

XI
540.53 GAS DC
C
Pucca T FOR Side Ver (West) 2.04
R Bldg. Corridor & Lobby= 45.63
5.03X2.28m LAND TO BE LEF
4.27m

E
C
DC

Garbage
4.57

IDE

E P.P < <


O P E N WID06m
EL
7 Std.
GAS
Semi RO AD WID EN DC
C

6 Std. Collection
WIDE R

DAP PROPOS ED 9.1 4M Fire Stair 13.66


DC

4M 5. P.P Semi
C
mW

C
ROA

DC

U/C
9.1 Bldg. Bldg. GAS
Pucca
EL
Pucca
D TP
G A R A G E
DCC
4.92
W A S A SE
Front/North Verandah
Garbage GUARD
5 Std.
IDE

22.8

WIDE

Collection GAS

OPO
P.P 6 Std. Apartment = 435.53
Semi
DC
4 Std.
20.2

C
Bldg. 9 Std
EL
4 Std.
PR Lift= 13.66 East Road/Front Ver 13.29
Bldg.
ROA

OAD
5m

Bldg. P.P U/C Pucca 1 Std. P.P &


6m

DC
C
Recharge pit for Bldg. P.P 5th floor Stair= 11.80 GA +0.75m
in Semi 540.53
r Dra
S
400 KW Rain water Bldg. Side Ver (West) 2.04

AY
Corridor & Lobby= 45.63
S L U M A R E A
5.03X2.28m LAND TO BE LEFT FOR
D

1.37m ROAD
D Cove Proposed Electric Connection Pucca
ROAD

2.28m

EW
3.6

A 3.71m
EL
14,000 Gallon
U/C O
E R P.P 2 Std. Proposed Water Connection 1
LP
Fire Stair 13.66
DC
C
DAP PROPOSED 9.14M ROAD WIDEN

RIV
6m

P.P
WID

22.
5 Std. 2 Std. 6 Std.

ED
m

85m
WID

4.92
AD 4.57
20.50m

6 Std. Bldg. Front/North Verandah


13.71

Bldg. Average plot level with


R OP.P Bldg. Bldg. Apartment = 435.53

WID
EL

E 3 Std.

20.2
P.P respect to road =+0.3m

.
ID Mosque
ER

2 Std. P.P Lift= 13.66 East Road/Front Ver 13.29


W 4 Std. Proposed Gas Riser (54nos)
4 Std. 2 Std.
m

3 .6 5 m
P.P

m
Bldg.

6m.
OA

Recharge pit for Stair= 11.80


9 Std. Recharge pit for 11.50m

4.25
Bldg. Bldg. Bldg. 540.53
Bldg. Rain water
6th floor Corridor & Lobby= 45.63 Side Ver (West) 2.04
D

P.P 6 Std. P.P Bldg.


Rain water P.P UP

>
m
PROPOSED 59

ROAD>
P.P 2. LAND TO BE
13.10m

Cover

Bldg. (20.50+2.60+18.89)X1.37m P.P Fire Stair 13.66


5 Std. 9 Std. Recharge pit for LEFT FOR 3.66M RO WID
AD EN U/C
18.89m

P.P
Semi P.P
Bldg.
Bldg.
Rain water PLOT 6 Std. Front/North Verandah 4.92

3.76
6 Std. U/C Apartment = 435.53
Drain

Pucca AD
IDE RO
PP 4 Std. Bldg. Bldg.
N Lift= 13.66 East Road/Front Ver 13.29
O PE Bldg. 1.83m W U/C

m.
4 Std. U/C 7 Std.
2.1

4.27m
12.95m

4 Std.
PP

7th floor Stair= 11.80

E
P.P 9 Std. Semi
540.53
4m

Bldg. 7 Std. P.P 2.04


3.65m

Recharge pit for Bldg. P.P Corridor & Lobby= 45.63 Side Ver (West)

D
PP

Bldg.
m

Rain water
Bldg. Bldg. U/C Pucca
94

I
3 Std. P.P Fire Stair 13.66
D >>

W
5.

P.P P.P
15.70m A
E RO
3Std.
WIDE

4 Std. Semi +1.22m


WIDE

4 Std. 3 Std. Recharge pit for Bldg. 4 Std. 4.92


D

<< 3.96m
Front/North Verandah
Bldg. Pucca Rain water Semi Recharge pit for
I
Bldg. SP 1 Std. Bldg. Apartment = 435.53
Rain water 1.37m
.
. 2 8 m W
R

2 Std. 4 Std.
Pucca Lift= 13.66 East Road/Front Ver 13.29 20.00m. .
<< 2
OAD

m
9 Std. 9 Std. P.P P.P P.P 8 Std. 5 Std. 3 Std. Bldg. Stair= 11.80 Proposed Electric Connection 2.08m. 1 .80
Bldg.
ROAD

4 Std. Bldg. 540.53

1.52m.
Bldg. 8th floor Side Ver (West) 2.04 400 KW
6 Std. SP Corridor & Lobby= 45.63

1.5
Bldg. Bldg. Bldg. Bldg. IP
Bldg.

3m
3 Std. 7 Std. Semi Fire Stair 13.66 Proposed Water Connection 1 m.
6 Std. U/C 13.7

.
Bldg. 5 Std. 3 Std. 7Std. Pucca 14,000 Gallon m. 3.76m. 2.44m.
Bldg. 5.22
D

0.44m.
Bldg. P.P
ROA
6 Std. P.P Bldg. 4.92

1.52
Front/North Verandah IP
P.P P.P 5 Std. Bldg. .
P.P .69m
IDE
Apartment = 435.53 Recharge pit for

IDE ROAD
6 Std. Bldg. P.P 6
W P.P

2.29m

m.
Bldg. Lift= 13.66 East Road/Front Ver 13.29
2 Std. m 3 Std.
P.P 3.66m W
Rain water

1.57m.
P.P P.P 4.5 7 6 Std. Bldg. 3 Std. Stair= 11.80 2.47m.

5.0m deep Shore Pile Placed @ 0.5m C.C


Bldg. 4 Std. Bldg. 9th floor 540.53

7.28m.
6 Std. Bldg. Bldg. SP Side Ver (West) 2.04

.
6 Std. P.P 5 Std. Semi Corridor & Lobby= 45.63 1.40m.
6 Std. Bldg.
Bldg. Semi P.P

distance for Basement Construction

Height=+36.12m
Bldg. 5 Std. Bldg. Bldg. 4 Std. Pucca Fire Stair

STAIR, U.G.W.R.
13.66 IP

(20.50+2.60+18.89)X1.37m LAND TO BE LEFT FOR 3.66M ROAD WIDEN


2 Std. Bldg. P.P P.P Bldg. Pucca Semi Semi U/C

O.H.W.R.
6 Std. P.P

from GL
Bldg. 3 Std. Machine room 32.43

4.76m.
Cover Drain

P.P Semi Bldg. Pucca Semi Pucca Roof N/A Slab Out Line
6 Std. 4 Std. Bldg. 49.53
5 Std. Pucca P.P i Semi Pucca Of Basement

1.07m.
P.P Stair 17.10 1.52m.
Bldg. 6 Std.
Bldg. 6 Std. Sem Bldg. Pucca
6 Std. a 5 Std.
Pucc
Bldg.

)
6 Std. Bldg. Total FAR Area 4627.23 1659.32 6286.55

Proposed Gas Riser (54nos


5 Std. 2.60m. 7.23m.
P.PDE ROAD

20.50m.
Bldg. P.P Bldg. P.P
2 Std. Bldg.
.95m I

of Basement +1.22m
Bldg.

1.52m.
3.02m.

13.7
Semi P.P P.P SP 4 Std. 6 Std.
Bldg.
Semi
3 W 0.85m.
ROOF OF PARKING (Beyond FAR)
Level= +3.66 m

E ROAD Bldg. Pucca P.P

1
3 Std. P.P Bldg. Recharge pit for
6 Std. P.P Pucca
W ID Semi 6.92m.

m.
4.57m 8 Std. P.P

1.65m.
Bldg. P.P Rain water
Pucca
Cover Drain

m
3.66

Bldg. 4 Std.

+1.22
Bldg. P.P P.P 6 Std.

Slab outline
DE ROAD
1.01m.
Semi Bldg. Bldg.

ING =
2.43m.
P.P
WI
AD

4 Std. 6 Std.
P.P 3.66m
1.80m.
8 Std. Semi 3 Std.
E ROAD
m

P.P Pucca

9.12m.
4 Std.

PARK
Semi 1.37m.
Semi Bldg. Bldg.
m W ID 10 Std. Bldg. Pucca Bldg. (20.50+2.60+18.89)X1.37m LAND TO BE LEFT FOR

4.04m.
4.57 P.P Pucca 6 Std. Bldg. IP
WID

RO

Bldg. Semi Pucca

FOR
P.P P.P P.P DAP PROPOSED 3.66M ROAD WIDEN
Pucca 6 Std. Bldg. m.
250m

1.43
O P E N
4.57m WIDE R

P.P P.P 6 Std. Bldg. 1.37m.

1.40m.
Semi NB: Set back from Road
3.01m WIDE
ER

P.P 2 Std. 2.34m. 4.50m

1.42
5 Std. 4 Std. Bldg. Centre is 4.50m
Pucca 2 Std. 4 Std. Bldg. PROJECT:

m.
Bldg. Bldg.
OAD

18.03m.
Bldg. Bldg. 0m. 1.00m.
2 Std. 11.5 5.41m.
Semi 5 Std. Recharge pit for

1.93m.
Bldg.

2.29
P.P Semi 4 Std. 2.08m.
ROOF OF PARKING
Pucca Bldg.

3.84m.
(Beyond FAR)
1 Std. Bldg. Level= +2.40 m Rain water

m.
Semi Semi Pucca P.P 5 Std. 6Std. IP
5 Std. U/C 2 Std. Bldg.
Pucca Pucca Semi Bldg. Bldg. Recharge pit for

2.59m.
SW 2.92m.

44.51m.
Bldg. Pucca Bldg. 4 Std. Rain water 5.02m.
P.P

45.52m.
LIFT, STAIR, U.G.W.R.

Septic Tank
Bldg.
OAD

OAD

1.63m.
4 Std. O.H.W.R. 0.94m.

5.31m.
R P.P 6 Std. Height=+36.12m
Semi
WID E Bldg. P.P
6 Std. Semi Bldg.

<< E X I S T I N G 1.52m/.91m W I D E R O A D >>


5 Std. from GL

5.0m deep Shore Pile Placed @ 0.5m C.C


3.01m

<< P R O P O S E D 3.66 W I D E R O A D >>


Pucca Semi 2.33m.
3 Std. Bldg. Pucca

distance for Basement Construction


Bldg. 1.32m.
6 Std. Bldg. 5 Std. Pucca
Semi 6 Std.

4.24m.
Bldg. 3 Std. Bldg. 5.00m. POWER:
Pucca 4 Std. Bldg. Bldg. P.P 4 Std. Green Area=243.87 sqm IP 1.78m.
IP

1.52m.
P.P P.P ROOF OF PARKING

13.10
Bldg. 6 Std. Bldg.

1.0m
(24.51% of land area) (Beyond FAR)

1.27m.
Semi 1.45m.

1.27m.
8 Std. Bldg. P.P Level= +3.66 m

Cover Drain
Pucca .
2.45m

m.
Bldg. P.P 8.23m.

2.30m.
5 Std.
5 Std. 2 Std. P.P Bldg. 1.07m.
4 Std.

1.52m.
Bldg. Bldg. 7.98m.
Bldg. P.P Semi ROOF OF PARKING (Beyond FAR)

1.48m.

1.47m.
4 Std. 6 Std. Level= +3.66 m
Semi Pucca 7.96m.

2.56m.
Bldg. 5 Std. Bldg. 2.01m
.
P.P Semi Pucca

18.89m.
Semi 2 Std. Bldg. Recharge pit for
Pucca 1.76m.
Pucca P.P Bldg.
P.P E RO
AD P.P 4 Std. Rain water 2.35m.

1.63m.
Semi Bldg. IP 1.65m.

N 6 Std.
2 Std.
66m WID 3 Std.
Pucca
Semi
SP 0.63m.
PROPOSED BUILDING
IP

5.12m.
Bldg.
3 . 10(TEN)-STORIED+1(ONE) BASEMENT

3.63m.
2.1
Bldg. Bldg.
Semi Pucca
>>

4m
ROAD
P.P Semi Height = +32.15m from GL
SITE PLAN E

.
Pucca
Semi
Pucca
W I D LEGEND
<< 1.83m
>>

P.P Semi Pucca . 5.87m. 1.94m. 1.76m. .


6 Std. Pucca 7 Std. NOTE: 2.01m 2.42m
Electric Line EL EL EL
OAD

1.38m

1.50m.

0.88m.
1.80m.

1.80m.
IP ROOF OF PARKING
6 Std. Bldg. 6 Std. Bldg. (Beyond FAR)

NO NATURAL ELEMENTS &

3.34m.
Water Line
Level= +3.66 m
Bldg. 3.00m. 3.73m. ADDRESS:

.
3 Std.
R

1.98m.
ROOF OF PARKING
Bldg.
4 Std.
HERITAGE BUILDINGS ARE (Beyond FAR)
Sewarage Line ARCHITECT:
E

Level= +3.66 m
5.48m.
D

IP
GAS Line

1.78m.
SITUATED WITHIN 250m DIAMETER 12.9
m WI

1.40m.

2.08m.
IP GAS GAS GAS
5m.
1.65m. Recharge pit for
OF THE PROPOSED SITE. 1.35m. Rain water DCC Drain DCC DCC DCC

0.28m.
m.

1.82m.
2.08

1.31m.
2
<< 2.66

3.
16 .01

0.73m.
0.76m. 1.81m.
Recharge pit for m m.
. m
Level= +1.22

.
m
Rain water 3.83m.

94
2.16m

5.
2.45m.
m. IP Slab Out Line
LAYOUT PLAN
2.71

2.00m
2.44m. 5.26m. IP Of Basement
IP

.
Slab Out Line FOR PARKING. LEVEL=+1.22m Scale: 1:200 ENGINEER:
Of Basement
15.70m

19.45m.