Using a Protimeter Moisture Meter
To Check Damp within a Building
Contents
Introduction ...................................................................................................... 2
Introduction
Checking damp and moisture within a building structure, is a very
comprehensive subject. This white paper highlights basic understanding of
moisture, some of the techniques to look for damp and how to use a digital
moisture meter to diagnose moisture levels.
1. What Is Damp?
Damp is caused by water getting into the property (structural) and moisture
building up within the property causing condensation (lifestyle).
b. Condensation (Lifestyle)
Lifestyle moisture issues are caused by normal daily activities (taking
showers and baths, washing and drying clothes, cooking and boiling
kettles), all produce warm air containing large amounts of water vapour.
If the warm air can’t escape through an open window or air vent, it
moves around until it finds a cold surface where it cools and forms
condensation.
Commonly timber will absorb more water molecules than a brick wall. Wood is
like a sponge, absorbing moisture directly from the buildings structure and
retain higher levels of moisture before directly being affected by the damp
process.
The follow table provides examples showing the percentage moisture and the
readings interpretation.
As shown, wood can be classed as dry at 12%, but brick would be saturated at
the same reading.
Example
A timber skirting which records a moisture reading of 12% (air dry), the
plaster could be around 0.5% and the brick about 1%. In severe
conditions you may see higher readings of skirting 22%, plaster 1% - 3%
and brick around 2% - 5%.
Pinpointing the damp is only possibly with an electronic moisture meter. These
instruments can detect moisture levels below levels that are visible or can be
felt.
When measuring moisture, take regular readings over the suspected area and
mark the boundaries of moisture levels. Develop a scaled drawing of the
moisture readings recording the levels within the affected areas to determine
the severity.
For a definitive guide into damp, I would recommend the Dampness In Buildings
book distributed by Protimeter. This is a comprehensive guide to moisture in
buildings. A copy can be purchased directly through our online store.
4. Measuring Moisture
Reliable electronic moisture meters from Protimeter are the preferred
instruments due to the renowned reliability, accuracy and quality.
a. Surface Moisture
A pin type moisture meter, like the Protimeter Digital Mini, can be utilised to
measure the surface moisture of a wall, wood and building structure. Simply
place the pins on the surface of the wall to take a reading.
The Protimeter Digital Mini measures using the %Wood Moisture Equivalent
(%WME) scale.
With a pin type instrument, it may be required to push the pins into the wall.
Some types of wall coverings will restrict the reading. But a word of caution,
pushing pins into a surface will leave a mark especially glossed paint, venires
and laminated surfaces.
b. Subsurface Moisture
A non-invasive (pin less) moisture meter will measure the subsurface moisture
to a depth of 20mm. This is advised where wall, floor and wood covering
prohibit moisture readings with a pin type instrument.
The Protimeter Aquant2 will measure using radio waves, penetrating beneath
the wall surface including wall paper, paint and even tiles. This allows the user
to undertake a very quick reading without damaging the surface. The
Protimeter Aquant2 can also measure moisture in veneered wood like a build-in
wardrobe, kitchen or fibreglass.
c. Moisture Readings
All Protimeter moisture meters will display the readings through a digital LCD
display and a simple colour coded LED display.
The digital LCD display will provide the moisture reading (%WME or %REL).
When undertaking readings, write down this measurement for future records.
To support the digital reading, Protimeter has developed a simple colour coded
LED scale to indicating the moisture condition severity. This provides a very
simple way to determine if the readings are Dry, Borderline and Damp.
Green - Dry
Air dry moisture content
Amber - Borderline
Excess of moisture is present. This moisture cannot be attributed to high
atmospheric humidity but to a definite source. If the reading in this zone
persists or increases, remedial action is needed. Decay likely.
Red - Damp
A serious moisture condition exists and immediate remedial treatment must be
effected. Decay inevitable.
Condensation occurs on cold surfaces (window, mirror, tiles, glass) where the air
borne water vapour condensates back into a liquid. Condensation is usually an
intermittent phenomenon, occurring frequently in winter and at night. Therefore
a range of readings will be required throughout the day in all rooms of the
property.
If you feel that condensation is a cause for some of the moisture problems, a
digital hyrometer will accurately measure the airborne moisture which creates
condensation. When measuring humidity, air temperature should be recorded
at the same time.
Measure for levels of humidity first, if high levels are recorded then there will be
a potential of condensation occurring in the property.
The standard sensor has a reading range of 30 -100 %RH. A digital sensor
featured in the Protimeter Psyclone records a range of 1.0 - 99.0 %RH.
After turning on the instrument, ensure the instrument is displaying %RH and
air temperature (TA). The instrument will then read both airborne humidity and
air temperature. Depending on lifestyle issues, different measurements will be
required throughout the day to develop a pattern when humidity occurs, which
room and cause of the humidity.
Internal humidity readings will increase if the outside weather conditions are
damp.
The simplest way to record the humidity levels within a property is to develop a
spreadsheet recording date, time, room, %RH and air temperature. Over the
period of a day, a picture of the humidity fluctuations will be seen.
If high levels of humidity have been recorded, it is best to check the surface
temperature to verify the potential of condensation.
Both the Protimeter Hygromaster and Protimeter Psyclone can measure for
condensation, reporting back the potential of condensation. An optional Surface
Temperature Probe accessory is required to undertake this procedure.
By operating the Temp Diff function, the operator will be able to determine if
surfaces are colder than the surrounding air temperature, creating
condensation.
However with the Protimeter MMS2 instrument, the Condensator Mode enables
the user to assess the risk of condensation occurring on surfaces or to confirm
whether or not condensation is present on a surface.