2023 Asenware Fire Alarm System & Fire Suppression and Fighting System Catalogue

Download as pdf or txt
Download as pdf or txt
You are on page 1of 36

Since 2005, Fire Alarm and Suppression

2023
System Manufacturer & Complete
Solution Provider.

China-Marketing Center

Shenzhen Asenware Test & Control Technology Co.,LTD


D-26H, Shihong Building, No.63 Fanshen Road, Baoan District, Shenzhen,
Guangdong, China -518101
LPCB Conventional
Fire Alarm Control System
AW-CFP2166
China-R&D and Supply Chain Center

Zhongshan Guta Fire Equipment Technology Co.,LTD


4F,10# ,Xingye Rd., Huoju District,Zhongshan City, Guangdong.

UK-Marketing Center
ASENWAR E LTD
6 Prospect Way, Royal Oak Industrial, Estate Daventry,Northamptonshire,
England,Nn118pl.

YouTube Website TikTok

Website: www.asenware.com LPCB Approved Addressable Addressable Fire Alarm Wired and Wireless Centralized Monitoring
www. asenwarefire.com Fire Alarm Control System
AW-FP300
Control System
AW-FP100
Addressable Fire Alarm
Control System
Emergency Luminaire
System
Email: [email protected] AW-FP128
Contents

01 Company Profile 27-28 Aspirating Smoke Detection System

02-06 LPCB Approved Addressable Fire Alarm Control System 29 Weatherproof Fire Alarm Devices

07-15 Addressable Fire Alarm Control System 30-34 ATEX Approved Explosion-Proof Fire Alarm Products

16-17 Addressable Explosion-proof Fire Alarm System 35-38 Fire Linear Heat Detection System

18 ASENWARE Global Fire Alarm Graphic Monitoring System 39 Voice Evacuation Control Panel and Speakers

19-23 LPCB Conventional Fire Alarm Control System 40 Fire Telephone System

24-26 Wireless Fire Alarm System


Contents

41-42 Centralized Monitoring Emergency Luminaire System 52-56 Water Based Fire Products

43-44 Detector Tester Series 57-58 ASTM A53 Seamless Steel Pipe & Fittings

45-47 Gas Suppression Release Control System 59 Foam Fire Extinguishing System

48 Fm200 Gas Fire Suppression system 60 Fire Hose Rack & Reel

49 Gas Extinguishing System 61 Hose Accessories & Fire Blanket

50 CO 2 Gas Extinguishing System 62 Sprinkler Series

51 Packaged Fire Pump System


Company Profile LPCB Approved Addressable Fire Alarm Control System

LOOP OUT

Who is ASENWARE?

ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provilder since 2005.

Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive
fire safety products line including addressable fire alarm system, conventional fire alarm system, central monitoring emergency
light system, fire telephone and voice evacuation system, fire pump, fire hose and gas suppression system.

Our fire safety products ,solutions and services are used in over 100 countries.

With over 200 employees work in United Kingdom-Marketing Center, China-R&D and Supply Chain Center , ASENWARE is
committed to design and manufacture the best fire safety products to reduce the risk of fire, and support the world to be safer
and more comfortable.

What do we offer the world?

We focus on the high quality products and ser vices supply only.

We always remember that quality is the cornerstone of our existence, and we will never reduce the quality for any reason.

Our products must comply with international standards, and must be stable and reliable in long term using.

We will continuously improve our products to be more excellent. In any time,we should not accept the poor quality results, or
keep a poor quality work just because of the old experience. We should always think what is the best and how can do the best.

We must keep our promises for our customers, we must provide products, ser vices and solutions to our customers with more than
their expect.

We create value for our customers.

We keep invest to design and update our products, ever y year we have new products and new solutions for fire safety market.

We focus on international standard and certificate fire safety products, until now we already got LPCB, TUV,BSİ, Intertek CE,
Bomba ,ATEX certificates for our different products.

Our products and ser vices support wholesalers, project contractors and building owners. We set up a cloud website that can
monitor all the running fire panels.Ever y agent, contractor, owner ,maintenance engineer can check the fire system real status
and get emergency alarm by mobile phone or email.

We support to design the projects based on NFPA and other international standards. All projects are designed and verified by
highly skilled engineering team. Moreover, we support our customers at site in different countries for commissioining and other
necessar y supports for the completion and submittal of the projects.

1 2
LPCB Approved Addressable Fire Alarm Control System LPCB Approved Addressable Fire Alarm Control System

AW-FP300 Fire Alarm Control Panel AW-FP312 Addressable Fire Alarm Control Panel

1-8 Loop Fire Panel

The purpose of the AW-FP300 Fire Alarm Control Panel (FACP) is to monitor input signals, give indications and possibly The purpose of the AW-FP312 Fire Alarm Control Panel (FACP) is to monitor input signals, giveindications and possibly
activate outputs as programmed. It is designed to comply with EN 54-2 and EN 54-4 with qualities of simple installation, activate outputs as programmed. It is designed to comply with EN 54-2with qualities of simple installation, operation and
operation and easy maintenance.The AW-FP300 panel is an addressable fire detection panel with 1 loop of 324 addressable easy maintenance.The AW-FP312 panel is an addressable fire detection panel with 1 loop of 120 addressable points and
points and expansion capabilities. It is compatible with other peripherals made by ASENWARE with its own protocol. expansion capabilities. It is compatible with other peripherals with the same protocol.

The AW-FP300 single loop 32 zone fire alarm control panel offers the following features The AW-FP312 addressable fire alarm control panel offers the following features

One loop with 120 addressable points


Up to 324 addresses in one loop, 648 addresses in two loops

CAN network 20pcs panel


Easy to read,4.3" color screen LCD with a resolution of 480x272

Graphic monitor
Zone indication and control panel (ZCP)for 32 zones gives a quick indication of the location of an alarm or fault

Record capacity of 1000 historical events for each of historical fire,historical fault and historical operation

CAN bus for interconnection of up to 20 FACPs and RS-485 for connection with up to 30 fire indicating panels per FACP

3 4
LPCB Approved Addressable Fire Alarm Control System LPCB Approved Addressable Fire Alarm Control System

Addressable
Addressable Smoke
Addressable Zone Module Strobe Sounder Base
Addressable Smoke Detector Addressable Heat Detector and Heat Combined Detector
AW-D310 AW-D321
AW-D301 AW-D302 AW-D303
Signal Loop 24V(20V~28V) , Loop input DC24V(20-28V)
Power 24VDC(20VDC~28VDC)
Loop<0.5mA;Power <15mA Power consumption ≤0.2W@DC24V

Loop<2mA ; Power <35mA -10℃~+55℃


4G GSM Module
- 10℃~+ 55℃ Relative Humidity ≤95% , non-condensing
AW-GSM200
Relative Humidity ≤95% , non-condensing

Programmer Addressablesounder beacon


waterproof base
AW-CODER2188 AW-BS03
Made of ABS material
4 Wire Addressable Sounder Beacon AW-D306 A device for giving specific ID to Complies with IP65 rating
Addressable Gas Detector 2 Wire A ddressable Sounder Beacon AW-D307 Addressable Manual Call Point all the addressable accessories
AW-D315 2 Wire Conventional Sounder Beacon AW-D316 AW-D305 which need to be configured with
Signal Loop 24V(18V~28V) AW-FP300 control panel.
Operating Voltage
Power 24VDC(20VDC~28VDC)
Standby Current Loop≤0.8mA ; Power≤2mA
Action Current Loop≤5mA ; Power≤15mA
Output Capacity 1A@DC30V
NC or NO input mode can be set
Input Mode Setting
by the jumper JP4.

Extension Box
AW- FP300EB
Extend 1 to 6 Loop cards

Loop Isolator 4 Wire Addressable I/O Module AW-D319 Addressable Repeater


AW-D314 2 Wire A ddressable I/O Module AW-D309 AW-RP2188

5 6
Addressable Fire Alarm Control System Addressable Fire Alarm Control System

AW-FP100 Fire Alarm Control Panel

1-8 Loop Fire Panel

LOOP OUT

Addressable Addressable Strobe Sounder


Annuciator LED with Wireless Transmitter
Main Board

LOOP IN
Addressable
Strobe Sounder Base

Asenware AW-FP100 Series Fire Alarm Control Panel are intelligent panels which are designed to make it suitable for most of
applications. The user friendly functionality makes it suitable to program and configure the devices. 7 " touchscreen display
shows the information for fire alarm, trouble, super visor y and other related information all the time.
AW-FP100 series can be configured with just a few devices for small building applications, or for a large area or high-rise
application. Simply add additional equipment to suit the application like detectors,modules and other compatible devices. It
is supplied with cabinet of IP 30 rating (standard). This panel fully comply with the requirement of EN 54-2 and EN 54-4.

Addressable Addressable The AW-FP100 fire alarm control panel offers the following features
Carbon Monoxide LPG Gas Detector
Detector
7" Touchscreen LCD color display
Ad dr es sa bl e
Power Supply 250 intelligent detectors or modules for one loop circuit

Up to 8 Loop Cards can be installed and configured

2-Wire cable for all addressable devices


Addressable Isolator Base
I/O Module Network Available Options: GSM/IP/Cloud/Modbus

Graphic remote monitor access system

7 8
Addressable Fire Alarm Control System Addressable Fire Alarm Control System

AW-FP200 Wired And Wireless Addressable Fire Alarm Control Panel AW-FP128 Wired And Wireless Addressable Fire Alarm Control Panel

The AW-FP200 series addressable fire alarm control panel is designed with 7-inch LCD display touch screen with button AW-FP128 wired and wireless fire alarm control panel adopts 3.2-inch LCD screen, key operation, simple operation, beautiful
operation, easy to operate, and nice human-computer interface.This machine can be connected to 8 loops. Each loop can be man-machine interface.The wired circuit of the machine can be connected to 128 devices, 80 groups of wireless circuits, a
connected to 250 devices, such as smoke detectors, temperature detectors, input/output modules, each loop can be wireless circuit can be connected to 20 wireless devices, such as smoke detector, temperature detector, input and output
connected to 10 groups of wireless loops, a group of wireless loops can be connected to 20 devices, such as smoke detector, module, etc.
temperature detector, input and output module, etc.
The AW-FP128 wired and wireless addressable fire alarm control panel offers the following features
The AW-FP200 fire alarm control panel offers the following features
3.2-inch LCD display screen operation.
7 inch color LCD display, touch screen operation
All addressable devices use a two-wire system
All addressable devices use a two-wire system

A wired loop can connect 250 wired addressable devices, including 10 groups of wireless loops. A single loop can connect 128 wired addressable devices

One set of wireless loops can connect to 20 devices


Up to 999 records of histor y can be saved (save when power off )
Max 8 loop cards can be installed

Up to 999 records of histor y can be saved (save when power off ) There are four access levels

Multiple access levels can beset It has a rechargeable backup batter y


It has a rechargeable backup batter y
Can simply judge the running status of the machine based on the LED lights
Can simply judge the running status of the machine based on the LED lights

Automatic search device Automatic search device

Each of the 8 panels can be controlled remotely Each of the 8 panels can be controlled remotely
USB software upper computer to check and set the device status and fire histor y records
USB software upper computer to check and set the device status and fire histor y records
It can bind 10 mobile phone numbers to receive panel alarm information.( The GSM module must be added)

9 10
Addressable Fire Alarm Control System Addressable Fire Alarm Control System

Addressable Monitor Module


AW-D110

AW-D110 is an intelligent addressable monitor module, which can be


configured with Asenware AW-FP100 Series Addressable Fire Alarm
Control Panel.Each point (device) can be given specific ID or individual
address, which allows the panel to continuously monitor specific location
Addressable Smoke Detector Addressable Heat Detector Addressable Smoke and Heat Detector (point).The module can be connected to Asenware conventional manual
AW-D101 AW-D102 AW-D138 call point and conventional detector.

Addressable Super visor y Module


AW-D111

AW-D111 is an intelligent addressable super visor y module, which can be


configured with Asenware AW-FP100 Series Addressable Fire Alarm
Control Panel.Each point (device) can be given specific ID or individual
address, which allows the panel to continuously monitor specific location
(point).This module can be connected with conventional beam smoke
detector, conventional flame detector, conventional gas detector.

Wireless Addressable Smoke Detector Wireless Addressable Heat Detector Wireless Addressable Smoke & Heat Detector
AW-D603L AW-D604L AW-D605L
Addressable Control Module
Alarm level ≥85dB /3m Alarm level ≥85dB /3m AW-D112
Smoke Alarm Sensitivity 0.18-0.3dBM 57°C (135°F) A2R 57°C (135°F) A2R
0 - 40°C (32~104°F) ≥10°C/2M A2R ≥10°C/2M A2R
AW-D112 is an intelligent addressable control module, which can be
Wireless transmit power +20dB Wireless transmit power +20dB Wireless transmit power +20dB configured with Asenware AW-FP100 Series Addressable Fire Alarm
Control Panel. Each point (device) can be given specific ID or individual
address, which allows the panel to give a voltage output signal(24VDC) to
control FPE or any other devices. AW-D112 control modules provides a
notification circuit to activate the notification devices conventional bell
and Sounder strobe.

Addressable Relay Module


AW-D113

Addressable Alarm Bell Addressable Strobe Sounder Addressable Manual Call Point AW-D113 is an intelligent addressable relay module, which can be
AW-D109 AW-D106 AW-D135A configured with Asenware AW-FP100 Series Addressable Fire Alarm Control
Panel. Each point (device) can be given specific ID or individual address,
which allows the panel to give a relay output signal to control FPE or any
other devices. AW-D113 control modules provides a fire signal with a
dr y-contact output for activating a variety of devices, such as fans,
dampers, control equipment, etc.

11 12
Addressable Fire Alarm Control System Addressable Fire Alarm Control System

Addressable Isolator Module Addressable LPG Gas Detector


AW-D114 AW-D132A

The gas detector is designed for single station use or for connecting to fire
AW-D114 is an intelligent addressable isolator module, which can be alarm or security alarm panel. Small and compact, the design and color
configured with Asenware AW-FP100 Series Addressable Fire Alarm makes it ideal for use in the home, small commercial properties, and
Control Panel. AW-D114 short-circuit isolator module is used to make recreational vehicles. It is intended to detect leakage of natural gas
sure the short circuit on the branch of the loop cannot affect the normal (methane gas),town gas, and bottled gas (propane gas) The gas detector
operation of the loop circuit can be mounted high (for methane gas) or low (for propane (LPG) gas). It is
equipped with a sturdy mounting bracket for quick , easy and safe
installation.

Addressable I/O Module Addressable Carbon Monoxide Detector


AW-D119 AW-D125A
The AW-D119 I/O module is used with AW-FP100 series addressable fire The addressable carbon monoxide detector AW-D125A is an intelligent
alarm control panel.It is mainly used to realize an output control for fire detector which can be configured with Asenware AW-FP100 series
linkage equipment (such as fire alarm bell and strobe horn) and receive addressable fire alarm control panel.
the fire signal for the detector which connecting to this module through Each point (device) can be given specific ID, which allows the panel to
the input port. And it can receive the feedback signals of the fire linkage continuously monitor specific detector location (point).
equipment so that a judgment on whether or not the fire linkage
equipment is operating normally can be done.

Isolator base
AW-D115
CAN Bus Transmitter
AW-D122 AW-D115 isolator base (hereinafter referred to as AW-D115), mainly used
to isolate a short circuit on the detector, to make sure other devices on the
This CAN Bus Transmitter AW-D122 is designed for extend the distance of bus(including Loop in addressable system and 24VDC in conventional
CAN Bus communication. It is suggested to be installed over each 400 system) to ensure normal operation.
meters.

Addressable Annunciator
AW-D116

Features
Three lines in LCD, each line 40 characters

LED indication for alarm, fault and super visor y

Push buttons to acknowledge the silence

Lamp test from key switch Programmer Addressable Detector 4G GSM Module
AW-FP100GSM-4G
AW-PR101L Strobe Sounder Base
AW-D120

13 14
Addressable Fire Alarm Control System Addressable Explosion-proof Fire Alarm System

Addressable Annunciator Board


AW-D117&AW-D118

Features
24 Zones Addressable
AW-D117
Annunciator LED Main Board

AW-D118 24 Zones Addressable


Annunciator LED Extension Board

Addressable Explosion-proof Addressable Explosion-proof


Optical Heat Detector with Base Optical Smoke Detector with Base
AW-D102EX AW-D101EX

Addressable Power Transmitter


AW-D121
Addressable Power Transmitter, an intelligent power supply,
which is designed to provide auxiliar y power when there is not
enough power from panel to devices.

Features
Addressable
Addressable Explosion-proof
2.5A@24VDC output Smoke and Heat Combined Detector with Base
AW-D103EX

EN54-4 standard

Include batter y charger

12V2.3AH*2 batteries optional

Power Supply
AW-D121C
The AW-D121C Power Supply is used with AW-CFP2166 series
conventional fire alarm control panel. It is mainly used to
increase the load capacity of the panel. And it can reset the
output of 24VDC by 3 inputs (volt free input, voltage input and
RS485).

Features
Surface mounting

Working status indicators Addressable Explosion-proof Addressable Explosion-proof


Manual Call Point Strobe Sounder
24VDC output short circuit protection function AW-D105EX AW-D106EX

Selectable input modes to reset 24VDC out

Compatible with the latest EN54-4 standard

15 16
Addressable Explosion-proof Fire Alarm System ASENWARE Global Fire Alarm Graphic Monitoring System

Addressable Explosion-proof Addressable Explosion-proof Addressable Explosion-proof


Optical Smoke Detector with Base Optical Heat Detector with Base Smoke and Heat Combined Detector with Base
AW-D101EX AW-D102EX AW-D103EX

Main Voltage: Loop 24VDC Main Voltage: Loop 24VDC Main Voltage: Loop 24VDC
Monitor : ≤1.2mA Monitor : ≤1.2mA Monitor : ≤1.2mA
Operating current: Alarm: ≤2.5mA Operating current: Operating current:
Alarm: ≤2.5mA Alarm: ≤2.5mA

Smoke Alarm alarm 57℃(135°F) Smoke Alarm


0.18dB/m~0.3 dB/m Fixed temperature: 0.18dB/m~0.3 dB/m
Sensitivity: A1R Sensitivity:

Ex-Atex Protection Ex-Atex Protection Gb/Exib Dt Ex-Atex Protection Gb/Exib Dt


Gb/Exib Dt
Level: Level: DA21 IP65 T85 Level: DA21 IP65 T85
DA21 IP65 T85
Temperature range:-10 to 50°C Rate-of-rise alarm: 7.1℃/5s A1R Rate-of-rise alarm: 7.1℃/5s A1R

Features
Support LAN and CLOUD mode

Multi Level Management

Automatically send fire or fault events Emails & SMS to the building managers, engineers or concerned person

CLOUD mode can monitor all running panels around the world

User-friendly,easy to operate and manage

Aesthetic design while maintaining the simplicity in drag and drop feature for devices to the layout
Addressable Explosion-proof Addressable Explosion-proof
Strobe Sounder Manual Call Point
AW-D106EX AW-D105EX

Main Voltage: Loop 24VDC Main Voltage: Loop 24VDC

Operating current: Monitor : ≤1.2mA Alarm Current: ≤10mA


Alarm: ≤650mA
Ex-Atex Protection
SPL: 110dB-120dB Exd II Ct6
Level:
Ex-Atex Protection Gb/Exib Dt
Temperature range: -20 to 50°C
Level: DA21 IP65 T85
Temperature range: -10 to 50°C

17 18
LPCB Conventional Fire Alarm Control System LPCB Conventional Fire Alarm Control System

AW-CFP2166 Conventional Fire Alarm Control Panel

1-32 Zone Fire Alarm Panel

Conventional Photo-Electric Conventional Photo-Electric Rate of Rise Temp Heat Detector


Smoke Detector Smoke Detector ROR/A2R
AW-CSD381 AW-CSD311 AW-CTD382

Main Voltage Zone 24V / 12V Main Voltage Zone 24V / 12V Main Voltage Zone 12V/24V DC

Fix Temperature
57℃(135°F)
Alarm
Rate of Rise Alarm 7.1 ℃/5s

Rate of Rise Temp Heat Detector Conventional Manual Call Point Horn Strobe
ROR/A2R AW-D135C AW-CSS2166-2
AW-CTD321

Main Voltage 9-28V DC

Fix Temperature
57℃(135°F)
Alarm
Rate of Rise Alarm 7.1 ℃/5s

Conventional Conventional Conventional Conventional


Fire Alarm Control Panel Fire Alarm Control Panel Fire Alarm Control Panel Fire Alarm Control Panel
1 Zone 2/4 Zone 6/8 Zone 12/16/ 32 Zone
AW-CFP2166-1 AW-CFP2166-2 AW-CFP2166-6 AW-CFP2166-12
AW-CFP2166-4 AW-CFP2166-8 AW-CFP2166-16
AW-CFP2166-20
AW-CFP2166-24
AW-CFP2166-28
AW-CFP2166-32

Features
AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. Conventional Sounder Beacon 6 Inch Fire Bell 8 Inch Fire Bell
AW-D316 AW-CBL2166-6 AW-CBL2166-8
It is modularized design, the panel can expand from 1 zone to 32 zones easily.

It has 2 levels control mode by a lock .

It has an optional GSM module for fire alarm by SMS.

19 20
LPCB Conventional Fire Alarm Control System Batter y Detector Series

Standalone Wireless Batter y Standalone Smoke Detector 10 Years Standalone Smoke Detector
Horn Strobe Horn Strobe Conventional Strobe Sounder Wifi Smoke Detector With Blister Pack AW-D615
AW-CSS2166-4 AW-CSS2166-5 AW-CSS2166-3 AW-D611W AW-D611

Operating voltage
M a in V o lta g e 9VDC Operating voltage
M a in V o lta g e 9VDC Operating voltage
M a in V o lta g e 3VDC

Monitoring Status ≤8uA Monitoring Status ≤8uA Monitoring Status ≤8uA


≤2.0S
Alarm Status ≤400mA Alarm Status ≤20mA Alarm Status ≤20mA

Alarm SPL ≥85dB@3m Alarm Sensitivity 0.18~0.26 dB/m Alarm Sensitivity 0.18~0.30 dB/m

Repeater Entrance LED Indicator Conventional UV Flame Detector


AW-CRP2166 AW-EL102 AW-FD602-UV
Wireless Addressable Smoke Detector Wireless Addressable Heat Detector Wireless Addressable Smoke & Heat Detector
AW-D603L AW-D604L AW-D605L

Alarm level ≥85dB /3m Alarm level ≥85dB /3m


Smoke Alarm Sensitivity 0.18-0.3dBM 57°C (135°F) A2R 57°C (135°F) A2R
0 - 40°C (32~104°F) ≥10°C/2M A2R ≥10°C/2M A2R
Wireless transmit power +20dB Wireless transmit power +20dB Wireless transmit power +20dB

220V Standalone LPG Gas Detector


Conventional Combined Smoke 10 Years Standalone Standalone Heat Detector AW-D132
Conventional 4 Wire CO detector
And Heat Detector Batter y Heat Detector AW-D612 Addressable LPG Gas Detector
AW-D125C
AW-D138C AW-D616 AW-D132A
Standalone batter y CO detector
24V DC 4 wire LPG Gas Detector
AW-D125S
Operating voltage: 9-28VDC @Zone Operating voltage: 3VDC AW-D132C-4W
M a in V o lta g e M a in V o lta g e

Main Voltage
M a in V o lta g e 9V DC
Standby Current: ≤120uA @Zone 24VDC Monitoring Status ≤8uA Monitoring Status ≤8uA
Maximum Alarm ≤ 15 mA @Zone 24VDC ≤20mA Alarm Status ≤20mA
Current (LED on)
≥85db@3m Weight about 120g Gas Detection CH4/LNG

21 22
LPCB Conventional Fire Alarm Control System Wireless Conventional Fire Alarm System

4 Wire Conventional UV Flame Detector


AW-D146R

This UV flame detector uses the best flame sensor. It


has sensitive response and large detection angle, and it
is consistent and long-term stable and reliable.
The red LED indicators on the flame detector provide
local 360° visual alarm indication.

Alarm level ≥85dB /3m


Sensitivity Grade 1
Operating Temperature -10°C~50°C
Wireless Conventional Fire Alarm
Control Panel
AW-CFP2166-4W
Beam Smoke Detector
AW-CFP2166-4W Wireless version features:
AW-BK901 1.Can connect both wired and wireless devices
2. Each zone can connect up to 20 wireless devices and 20 wired devices,increasing the capacity of each zone
3. Connect wireless devices, save cost
4. Wireless detectors are low power and can be used forup to 5 years
5.Each wireless detector contains a sounder, Alarm>75db
6.The control panel can remotely reset and mute the wireless detector

The AW-BK901 infrared linear reflex beam smoke detector, is being


designed for fire prevention in the open area, is used with the fire
Wireless Addressable Smoke Detector Wireless Addressable Heat Detector Wireless Addressable Smoke & Heat Detector
alarm control panel.The detector is made up of the combination unit AW-D603L AW-D604L AW-D605L
of the emitter and the receiver as well as the reflecting mirror .The
signal issued by the emitter enters into the receiver after reflection
by the reflector. Alarm level ≥85dB /3m
Alarm level ≥85dB /3m
Smoke Alarm Sensitivity 0.18-0.3dBM 57°C (135°F) A2R 57°C (135°F) A2R
Operating Environment
0 - 40°C (32~104°F) ≥10°C/2M A2R ≥10°C/2M A2R
Power supply voltage: 16V-28VDC Alarm current <33mA
Wireless transmit power +20dB Wireless transmit power +20dB Wireless transmit power +20dB
Overall power consumption: <3W Debug current <20mA Dust Smoke Detector
Monitoring current 12mA AW-CSD313

Use conditions:Temperature:-10°C~+50°℃ ,Relative humidity <95%

Protective area:The maximum protective area of the detector is


1400m2 (14x100=1400m2) and the maximum width is 14m.

AW-BK901-20 20meters with 1 reflector


Wireless Strobe Sounder Wireless Manual Call Point
Wireless Addressable
AW-BK901-40 40meters with 1 reflector AW-D106A AW-D135W
Programmer
AW-PR101L
AW-BK901-70 70meters with 4 reflectors
IP30
AW-BK901-100 100meters with 4 reflectors

23 24
Wireless Fire Alarm System Wireless Fire Alarm System

W ireless Conventional Fire Alarm Wireless Addressable Wireless Addressable Wireless Addressable Wireless Addressable
Control Panel Smoke Detector Heat Detector Smoke Detector Heat Detector
AW-CFP2166-4W AW-D603L AW-D604L AW-D603L AW-D604L

Wireless LoRa
WIFI Transmitter
AW-D139

Addressable Strobe Sounder


with Wireless Transmitter
AW-D106A
Wireless Addressable Wireless Addressable
Smoke and Heat Detector Manual Call Point Max 20
Max 20 AW-D605L AW-D135W Wireless devices Wireless Addressable Wireless Addressable
Wireless devices In one zone Smoke and Heat Detector Manual Call Point
AW-D605L AW-D135W
In one zone

Wireless Addressable Wireless Addressable Wireless Addressable


Fire Alarm Control Panel Smoke Detector Heat Detector
AW-FP128 AW-D603L AW-D604L

Standalone Wireless Batter y


Wifi Smoke Detector
AW-D611W

Addressable Strobe Sounder


with Wireless Transmitter Wireless Addressable
Wireless Addressable
AW-D106A Smoke and Heat Detector
Manual Call Point
AW-D605L
Max 20 AW-D135W
Wireless devices
In one group

25 26
Aspirating Smoke Detection System Aspirating Smoke Detection System

Combustion analysis:

Warning Alert Action Fire 1 Fire 2

Aspirating Smoke Detection System Aspirating Smoke Detection System


AW-AS200 AW-AS100

Advantages
Earlier detection with high sensitivity

Immunity to false alarms

Cost-effective maintenance solution

Features
Cloud Chamber principle

7 inch color touch screen

More than 10 years ser vice life


Automatic cleaning function
Convenient maintenance solution
Multifunctional network solutions

27 28
Weatherproof Fire Alarm Devices ATEX Approved Explosion-Proof Fire Alarm Products

Explosion-Proof Infrared
Weatherproof Fire Alarm Series
Beam Smoke Detector
AW-BK901EX
Features

Weather proof The AW-BK901EX type explosion-proof infrared beam smoke


detector is a non-coded reflective linear infrared beam
Dustproof smoke detector. The detector must be used in conjunction
with the reflector, and one or four reflectors should be used
Good sealing according to the installation distance between the two
devices.
Factor y direct sales
The detector has advanced functions and powerful analysis
and judgment capabilities.Through our original program, it
Quality assurance can automatically complete system debugging,
compensation for changes in the external environment, fire
alarm and fault judgment, and the output status is displayed
through indicator lights and terminals.

Features

Newest and reasonable structure design

Sensitive adjustment, accurate positioning

Good performance, easy to install

Features

Diameter : 116mm

Inner diameter : 112.5mm

Aperture: 34mm

Height: 64mm
Smoke detector Weatherproof base
Horn Strobe
AW-WB02
AW-CSS2166-4W

Applicable Products
Suitable for most models
of smoke detector

Explosion-proof fire alarm bell Explosion-proof safety barrier Explosion-proof strobe sounder
AW-CBL2166EX AW-D137EX AW-CSS2168EX
Main Voltage 24 VDC Main Voltage DC 24V Main Voltage DC 24V
Operating current Alarm≤25 mA Operating current Alarm≤25 mA Operating current Alarm≤250 mA

Applicable Products Ex-Atex Protection Level


Size (L*W*H)
Exd II CT6 Gb
260* 152* 80mm
Ex-Atex Protection Level
Size (L*W*H)
Exd II CT6 Gb
260* 152* 80mm
Ex-Atex Protection Level
Size (L*W*H)
Exd II CT6 Gb
260* 152* 80mm

Features

Protection level:IP67
Explosion-proof Siren
Function:Dust-proof;Rain-proof AW-SP04EX
Main Voltage 24 VDC
L*W*H:176*125*72mm
Alarm Current ≤600 mA
Atmospheric Pressure 80kPa~110kPa
Outlet Thread G1/2

Conventional
Weatherproo f Box
Manual Call Point
AW-WB001
AW-D135C

29 30
ATEX Approved Explosion-Proof Fire Alarm Products ATEX Approved Explosion-Proof Fire Alarm Products

Explosion-Proof Gas Detector


AW-CGD2166EX

AW-CGD2166EX intelligent digital readout transmitter is a four-wire system and meets the international standard digital
transmitter which can convert the gas concentrations into standard a 4-20mA current signal. It"s suitable for the industrial LED
to display and the sensor is easy to use and plug and play. AW-CGD2166EX has many advantages: high performance, stable and
reliable operation, easy to install and maintain, and it can measure full range of gas and so on, which can meet the high demand
in the industrial site safety monitoring. It"s widely used in petroleum, chemical, engineering,metallurgy, petrochemical, gas
transmission and distribution, biochemical, medicine,
water treatment and other industries.

Explosion-proof optical Explosion-proof heat detector Explosion-proof


smoke detector AW-CTD382EX smoke and heat combined detector
AW-CSD381EX AW-D138EX

AW-CSD381EX AW-CTD382EX AW-D138EX

Gb/ExibDtDA21IP65T85

Explosion-proof weatherproof Explosion-proof manual call point Explosion-proof fire strobe


strobe sounder AW-D135EX AW-CSS2166EX
AW-CSS2167EX

AW-CSS2167EX AW-D135EX AW-CSS2166EX

110-120dB

31 32
ATEX Approved Explosion-Proof Flame Detector ATEX Approved Explosion-Proof Flame Detector

Explosion-proof ultraviolet Explosion-proof Ultraviolet Explosion-proof Ultraviolet & Infrared Explosion-proof Infrared 3
Product Name & infrared 3 flame detector Flame Detector Product Name Combined Flame Detector Flame Detector

AW-FD704EX AW-FD706EX AW-FD707EX AW-FD708EX


Model Model

Spectrum Range UV(185-260nm),IR (3.8um/4.3um/5.0um) UV 185-260nm Spectrum Range UV 185-260nm IR 4.3-5.0μm IR 3.8-5.0μm

Detection Angle 120° 120° Detection Angle 120° 40m 90° 40m

Sensitivity Level Grade l Grade l Sensitivity Level Grade l Grade l

24VDC(18-30VDC) 24VDC(18-30VDC) 24VDC(18 to 30VDC ) 24VDC(18 to 30VDC )


Main Voltage Main Voltage

Exd IIC T6 Gb/Ex tD A21 T80°C Exd II C T6 Gb/tD A21 IP66 T80°C Exd II C T6 Gb/tD A21 IP66 T80°C Exd II C T6 Gb/tD A21 IP66 T80°C
Ex-Atex Protection Level Ex-Atex Protection Level

Protection class IP66/IP67 IP66/IP67 Protection class IP66/IP67 IP66/IP67

Temperature range: -10 to 55°C Temperature range: -40℃~70℃ Temperature range: -40 to 70°C Temperature range: -40 to 85°C
(14~131°F) -40 to 70°C (-40~158°F, Storage temperature range:(-40~-85°F) (-40~158°F) Humidity: 0 to 96% RH, non-condensing
Enhance Type) Humidity: 0 ~ 96%RH (non-condensing) Humidity: 0 to 96% RH, non-condensing
Environmental Humidity: 0 to 96% RH, non-condensing Environmental

1 × 3/4NPT 、 M25*1.5 、 G3/4


Elecitrical Interface RS-485/RS-232;HART 1x3/4NPT, M25*1.5,G3/4, optional Elecitrical Interface 1x3/4NPT, M25*1.5,G3/4, optional
(Adapters can be customized
according to requirements)

Size 119mm* 141mm* 120mm 120mm* 95mm* 85mm Size 120mm* 95mm* 85mm 120mm* 95mm* 85mm

Weight About 3 Kg About 3 Kg Weight About 3 Kg About 3 Kg

Remote control function Adjust the sensitivity level: 1 to level 3 Remote control function Adjust the sensitivity level: 1 to level 3
Automatic reset Automatic reset

33 34
Fire Linear Heat Detection System Fire Linear Heat Detection System

Fire Linear heat cable

Conventional Fire Alarm Interface Module End of line Module


Control Panel AW-D401 AW-D402
AW-CFP2166-4

Linear Heat Detection Cable Model AW-D4068 AW-D4088 AW-D4105 AW-D4138 AW-D4180
(Conventional (Conventional (Conventional (Conventional (Conventional
Type 68°C) Type 88°C) Type 105°C) Type 138°C) Type 180°C)
Features

Line coverage...continuous sensitivity.


AW-D4068-P AW-D4088-P AW-D4105-P AW-D4138-P AW-D4180-P
(CR/OD Type 68°C) (CR/OD Type 88°C) (CR/OD Type 105°C) (CR/OD Type 138°C) (CR/OD Type 180°C)
Six alarm temperature ratings.

Withstands severe environmental conditions.


AW-D4068-E AW-D4088-E AW-D40105-E AW-D4138-E AW-D4180-E
Approved for hazardous locations. (EP Type 68°C) (EP Type 88°C) (EP Type 105°C) (EP Type 138°C) (EP Type 180°C)

Easy to install, test. Parameter

Compatible with other devices on same circuit. Alarm 68°C 88°C 105°C 138°C 180°C
Temperature

Ambient
45°C 60°C 75°C 93°C 121°C
temperature (Max)

-55°C for CR/OD Type -55°C for CR/OD Type -55°C for CR/OD Type -55°C for CR/OD Type -55°C for CR/OD Type
Ambient
Temperature (Min)
-40°C for -40°C for -40°C for -40°C for -40°C for
Conventional Conventional Conventional Conventional Conventional
and EP Type and EP Type and EP Type and EP Type and EP Type

Storage UP TO 45°C UP TO 45°C UP TO 70°C UP TO 70°C UP TO 105°C


Temperature

Alarm Deviation ±3℃ ±5℃ ±5℃ ±5℃ ±8℃

Dimensions 90mm×85mm×52mm Operating Voltage No Electronics


Operating environment Temperature:-45℃--+60℃ Operating environment Temperature:-45℃--+60℃
Relative humidity 95% Relative humidity 95% Alarm Response 10 (Max) 10 (Max) 15 (Max) 20 (Max) 20 (Max)
IP Rating IP66 IP Rating IP66 Time (s)

35 36
Fire Proof Cable Fire Proof Cable

Fire Proof Cable


Conductor : 1/1.63 BC

Features Inner wire:brown,blue(UL 105°PVC)

Oxygen-free Copper Drain:1/0.4 Tinned Copper

Wrapping:aluminum foil
High temperature resistance
Outer jacket: Red (UL 105° PVC-55P)
Halogen and smoke free

Quality Assurance

Conductor : 1/1. 02Bare Copper Conductor : 1/1.29Bare Copper


Core: Red. Black (UL105° PVC-35P) Core: Red. Black (UL105° PVC-35P) AW-FPLR2X2.5 (14 AWG)
Model
Drain: 1/0. 4Tinned Copper Drain: 1/0. 4Tinned Copper
Wrap:aluminum foil Wrap:aluminum foil
Outer jacket: Red (UL 105° PVC-55P) Outer jacket: Red (UL 105° PVC-55P)
Conductor 1/1.63 solid bare copper

Max conductor resistant Ω/KM (20℃) 8.45

Insulation thickness 0.51 mm


Min insulation thickness 0.46 mm

2.2±0.1
Inner wire brown.blue(flame retardant PVC)

6.0±0.3 Wire numbers 2 core


Drain wire 0.4mm tinned copper
Wrapping Al-foil

Model AW-FPLR2X1.0(18 AWG) Model AW-FPLR2X1.5 (16 AWG) Jacket red (flame retardant PVC)
OD 6.8±0.3 mm
Conductor 1/1.02 solid bare copper Conductor 1/1.29 solid bare copper
Jacket thickness 0.74 mm
Max conductor resistant Max conductor resistant
21.4 13.5 Min jacket thickness 0.62 mm
Ω/KM (20℃) Ω/KM (20℃)
Insulation thickness 0.38 mm Insulation thickness 0.44 mm Rated temperature 105℃
Min insulation thickness 0.33 mm Min insulation thickness 0.39 mm Rated voltage 300V
Inner wire brown.blue Inner wire brown.blue
Fame retardant rating Vw-1
(flame retardant PVC) (flame retardant PVC)
Wire numbers 2 core Wire numbers 2 core Application fire alarm systems
Drain wire 0.4mm tinned copper Drain wire 0.4mm tinned copper
Wrapping Al-foil Wrapping Al-foil
Jacket red (flame retardant PVC) Jacket red (flame retardant PVC)
OD 5.2±0.3 mm OD 5.8±0.3 mm
Jacket thickness 0.58 mm Jacket thickness 0.64 mm
Min jacket thickness 0.46 mm Min jacket thickness 0.52 mm
Rated temperature 105℃ Rated temperature 105℃
Rated voltage 300V Rated voltage 300V
Fame retardant rating Vw-1 Fame retardant rating Vw-1
Application fire alarm systems Application fire alarm systems

37 38
Voice Evacuation Control Panel and Speakers Fire Telephone System

Voice Evacuation Control Panel Addressable Fire Telephone Panel


AW-VP350 AW-FT599

AW-VP350 Voice Evacuation Control Panel and The addressable fire telephone panel is suitable
speakers are standalone public audio system for for communication and during any fire or
emergency evacuation. When get alarm input emergency in the building. In case of fire alarm at
from other fire alarm system or security alarm the application site, the site personnel can call
system, it can play the pre-recorded audio track the host through extension and contact the
to the speakers automatically. It also can control center in time. The operator in the
broadcast the microphone real time sound, or control center can also call the extension at the
other line in sound. It also support RS485 site through the panel to know the situation on
communication with ASENWARE AW-FP300 the site.
series addressable fire alarm control panel.

Features Features

Maximum power output: 350Watt. With the two-bus technology, the power supply and communication are compatible on two buses, and are not divided
into the positive and the negative, convenient for debugging
Speaker driving mode: constant voltage.
It has perfect detection measures, which can detect the short circuit and open circuit of the bus, and make sound and
Evacuate message up to 1 minute. light alarm

The anti-interference performance of hardware and software allows for the adaptability tovarious complex environments.
Background audio: USB2.0
The voice is subject to differential transmission on the bus, with strong anti-interference capability.
Complies with EN54 part 16.
The application of silica gel button presents a beautiful appearance, good hand feeling and long ser vice life.
Network function (work with AW-FP300 series addressable fire alarm control panel)
The panel and extension can call each other and make full-duplex call, and the host can communicate with three
Maximum 15 pcs AW-VP350 can be connected with 1 pc AW-FP300 addressable fire alarm control panel. extension telephones at the same time.
It has the function of recording and displaying the calling and answering time, and can quer y 120 records of calling and
2.6.2 Each AW-VP350 panel can be programmed to maximum 20 channels and controlled by AW-FP300 addressable response time between the panel and the extension.
fire alarm control panel
The recording is subject to circular coverage, first-in-first-out mode and automatic recording is enabled during a call.

Conventional Fire Telephone System


AW-FTP2008(8 zones)

The conventional fire telephone panel AW-FTP2008 is a


communication equipment which provides a convenient
means of fire reporting. It has well-mounted structure
and is easy to install, suitable for small systems. It can
Ceiling Speaker Ceiling Speaker Wall Mounted Speaker 15W Water Proof Speaker 30W Water Proof Speaker apply in scenarios like communication between the
AW-SP01 AW-SP02 AW-SP03 AW-SP04 AW-SP05 control room and the fireplace,fire-fighting command,
evacuation rescue, etc.

Addressable Conventional
Fire Telephone Jack Fire Telephone Handset
AW-D501 AW-D502

39 40
Centralized Monitoring Emergency Luminaire System Centralized Monitoring Emergency Luminaire System

Emergency Luminaire System


Single loop
This control system is designed for managing,
Maximum 500 emergency lights per
testing, monitoring and controlling emergency loop
lighting which is mounted dispersedly. AW-EP500 Up to 16 non- source emergency
zone input
Up to 16 testing groups

Features

7 inch colorful LCD display 220VAC 50/60Hz power supply


3 Hours battery discharge
Easy operating time 48pcs LED lights
670lm
Convenient using

Communicated by PLC 220VAC 50/60Hz power supply


3 Hours battery discharge
Easy Mounting time 16 pcs LED lights Double
side
Low maintenance cost

Features

Maximum 500 lightings


110V-127VAC 50/60Hz
Simultaneously and remotely control one or more lightings
220V-240VAC 50/60Hz
Non-maintaines
More than 500 histor y events record
LED 16pcs/bar, 1/2/3/5 bar
Nickel-cadmium or Lead-acid
Up to 16-way non-source emergency input signs testing

Up to 16 lighting zones 220VAC 50Hz/60Hz ±10%


-5° C~ 40° C Rh≤92% surface
Up to 16 testing groups without condensation
SMD 2835 12PCS .
Detecting batter y fault, LED source fault, AC fault and communication fault for single emergency lighting
220V-240VAC 50/60Hz
AW- EL203 Nicke l-cadmium 3.6V
<24 hours

220VAC 50Hz + 10%- 15%


1.2V 800mAh
0.5 m㎡

110V-120VAC or 220VAC 50Hz


AL housing and 6mm acrylic panel
8 LED, 0.5W
3.6V 500mAh Ni-Cd
>90 min

220VAC 50/60Hz
Twin Lamp AW-EL208 2150lm
Emergency Light <24 hours
2*10w

220VAC 50/60Hz
LED Lamp AW-EL103 ≥220lm
The installation can be performed per below figure in actual condition.Exit Lights and Emergency lighting can be Emergency Light <24 hours
connected to directly from the panel and power would be supplied from the panel itself. Panel has two sources, one is AC
mains and another one is 24 Volts batter y (or two 12V batteries).

41 42
Detector Tester Series Detector Tester Series

Smoke & Heat Detector


Heat Detector Tester 2 in 1 Tester
AW-D202 AW-D206

Smoke & Heat Detector Disassembly tool


AW-D208

Accessor y list
Connecting rod*5 Strong light flashlight

Cylindrical fixture cap*3 Rotate tong*3

Mechanical disassembly head Height adjusting gasket*3

Torch holder Key*2

Flame Simulator Handle rod


Smoke Detector Tester AW-D204 Smoke & Heat Detector
AW-D201 Disassembly Tool
AW-D208

Flame Simulator
AW-D204
Features

Batter y voltage:DC7.4V.2200MA/H

Charger output:DC8.4V, 1000MA


Smoke Detector Tester Heat Detector Tester
The total length of the tester :2.5m
AW-D201 AW-D202
Materials of the tester :aluminum
Features Features
Materials of the connecting rod:stainless steel
Length 1.6 meter x Dia.32mm Heating Element :220V/100W or 110V/100W
Materials of package box:aluminum
Light Weight Aluminium pole Length 1.75meter x Dia.32mm Light weight
Infrared waveband scope of (0.5 u m-5.5 u m)
Aluminum Pole
Triggering mechanism
Cable Length 10 meters ultraviolet waveband scope of (185nm-255nm)
Aluminium case with lock
Aluminum case with lock
Smoke & Heat Detector 2 in 1 Tester
AW-D206

43 44
Gas Extinguishing System Gas Extinguishing Release Control System

Mode Switch
AW-GD203

Gas Extinguishing Release Control System


AW-GEC2169

Fire Extinguishing System CO 2 Extinguishing System Packaged Fire Pump


Fm200/FK-5-1-12 System

4G GSM Module
AW-GSM200

45 46
Gas Extinguishing System FM-200 Gas Extinguishing System

AW-GEC2169 Extinguishing control panel


AW-GEC2169 gas extinguishing control panel is
designed in compliance with the requirements
of European standards of EN54-2, EN54-4 and
EN12094-1. This panel can be used in
FM200,CO2, IG541, N1230 and other gas fire
extinguishing systems.

Features

Alarm input: four alarm zones signal input, each zone can connect up to 16 detectors.

EM valve output: control the output of electromagnetic valve.

Panel outputs: circuit fault output / alarm output/ fire extinguishing signal output/24VDC output other parts working
condition.

Power output: resettable 24VDC output, 200mA current-limited protection.

Automatic power shift: 220VAC power and standby batter y power can be switched automatically.

GSM module (optional): GSM module allows users to receive alarm information by SMS.

FM-200/FK-5-1-12 Fire Extinguishing System


Asenware Clean Agent Fire extinguishing systems utilizes FM-200 FK-5-1-12 as extinguishing gas. Asenware gas
extinguishing systems are available as Engineered and Pre-Engineered Systems (Cabinet System).

Cabinet Type Manifold Type

47 48
Gas Extinguishing System CO2 Gas Extinguishing System

Hanging Type Gas Extinguishing System CO2 Gas Extinguishing System

Different from piped network type gas extinguishing the hanging type will be simple to install,no pipeline installation. CO2 Gas Extinguishing System is a kind of intelligent automatic
extinguishing system. In accordance with requirements for
use in different places for application, the unit independent
system and combined distribution system can be constituted
and the way of total flooding extinguishing can be used in
order to realize the extinguishing protection of single
protection area and multi-protection area. CO2 gas
automatic extinguishing system has advanced
technology and high extinguishing efficiency and can be
maintained easily. This system has 3 start-up modes
including automatic operation, manual operation and
mechanical emergency operation.

1. Bracket of storage bottle group of extinguishing agent


2. Storage bottle of extinguishing agent
3. Start-up bottle
4. Electromagnetic actuator of start-up bottle
5. Low-discharge and high-seal valve
6. Check valve of Start-up gas
7. Start-up pipe line
8. High-pressure hose
Electric Hanging Type Fixed Temperature Hanging Type 9. Weighing and leak detection device
10. Transmission pipeline of extinguishing agent
11. Pressure signal device
12. Safety valve
13. Check valve of extinguishing agent
14. Nozzle
Applications 15. Header pipe
16. Mechanical emergency start-up handle
Electronic computer room, a data processing center, telecommunications facilities,process control,expensive medical
equipment, industrial equipment, librar y,museum and art galler y, clean room, anechoic chamber,emergency power
facilities,flammable liquid storage area, etc.

This system is mainly suitable for the following fire situation

Gas fire in the event that gas source can be cut off before extinguishment;

Liquid fire or fire due to fusible solids such as paraffin and asphalt;
Fire Detection Tube Suppression System
Fire on solid surface and deep-seated fire of partial solids such as cotton, fabric, and paper ;
Features
Electrical fire.
Agent: FM 200/FK-5-1-12/CO2

Working Pressure: 14bar

Test Pressure: 25bar

Working Temperature: -30"c-+60"c

System Activated Temperature: 140℃±10℃

49 50
Packaged Fire Pump System Water Based Fire Products

Packaged Fire Pump system Fire sprinkler system


Asenware packaged Fire Pump system, can provide the complete skid for Fire Pump ser vice. Systems The fire sprinkler system is an active fire protection measure, consisting of a water supply system, providing adequate
include the pump, driver, controller and jockey pump all mounted on a common base. Controller is pressure and flow rate to a water distribution piping system, onto which fire sprinklers are connected. Although
pre-wired to the drivers. historically only used in factories and large commercial buildings, systems for home and small building are now
available at a cost-effective price. Fire sprinkler systems are extensively used worldwide with over 40 million sprinkler
heads fitted each year. In buildings completely protected by fire sprinkler systems, over 99% of fires were controlled by
fire sprinklers alone.

Bore
Diameter

Features

Full Assembly (Electric, Diesel and Jockey Pumps)

Common Base

Suitable Suction and Discharge Piping

Includes Check Valve, Isolation Valves and Pressure Gauges

Diesel Fuel Tank Mounting (optional ) and Batter y Connection

Suitable Pressure Tank

Pre -Assembled Controller

Automatically run and stop jockey pump, electrical motor pump and diesel pump.

Automatically charge the batter y.

Special water flow path design for high efficiency.

Full test with pressure guage and flow meter at same time.

51 52
Water Based Fire Products Water Based Fire Products

Boundar y Dimension Unit:mm


Nominal Pressure(Mpa)
DN L HA HC

50 178 322 374

65 190 332 398

80 203 350 429


1.6MPa
100 229 420 524

125 254 581 721


2 Way Fire Hydrant 3 Way Fire Hydrant Flange Type Landing Valve
150 267 581 736
Gate Valve
DN50-DN200 200 292 736 942
Outlet Size 2 x2.5" Outlet Size 1 x4" & 2 x2.5" Outlet Size 2.5"
Inlet Size 4" Inlet Size 6" Inlet Size 2.5"
Material Cast Iron Material Cast Iron Material Brass
Working Pressure 15 Bar Working Pressure 15 Bar Working Pressure 1.6 Mpa

Nominal Pressure(Mpa) DN H1 H2 H3 D1 D2 L1

50 70 130 68 120 95 43

65 76 143 68 136 109 46

80 86 155 68 160 124 46


1.6MPa
100 104 170 68 182 153 52

125 118 190 68 215 179 56

150 132 210 68 238 206 56


Butterfly Valve 200 243 85 295 264 60
167
DN50-DN200

Thread Type Landing Valve 2 Way Breeching Inlet 4 Way Breeching Inlet

Nominal PN16
Nominal Pressure(MPa) L H H1
Diameter DN (mm) D D1
Outlet Size 2.5" Outlet Size 2x 2.5" Outlet Size 4x 2.5"
Inlet Size 2.5" Inlet Size 4" Inlet Size 6" 50 240 160 125 265 210

Material Brass Material Cast Iron Material Cast Iron


65 240 180 145 310 215
Working Pressure 1.6 Mpa Working Pressure 10 Bar Working Pressure 10 Bar
80 292 195 160 350 245

1.6MPa 100 325 215 180 460 305

125 340 245 210 520 365


Pressure Reducing Valve
DN50-DN200 150 403 280 240 570 415

200 435 335 295 695 510

53 54
Water Based Fire Products Water Based Fire Products

L H
Nominal pressure(MPa) DN
flange flange
65 225 135

80 280 175

100 300 195


1.6MPa 125 350 220

150 390 240

200 500 335


Y-Strainer
DN65-DN200
Sight Flow Glass type Sight Flow Thread type Sight Flow Flange type
DN15-25 DN32-DN80 DN200

Test pressure (MPa)


Applicable Operating
Nominal pressure(MPa)
medium Humidity
Shell Seal

Clean water
and sewage
1. 76 without ≤80℃
1.6MPa 2.4
impurities

Main Relief Valve


DN 50-DN 200 Flexible Coupling Check Valve Flow Meter
DN 50-DN 200 DN 50-DN 200 DN 50-DN 200

Nominal pressure(MPa) Installation Nominal Working Sensitivity


diameter pressure(Mрa) L/min

flange
DN25
1.6MPa DN50
DN65
Saddle type DN80
1.2 15<Q<37.5
DN100
DN125
welded DN150
DN200

Air Vent Seamless Galvanized Steel Pipe Pipe Fittings


Flow Indicator DN 50-DN 100 ASTM A53 Variable
Silk mouth type
DN 25-DN 200

55 56
ASTM A53 seamless steel pipe ASTM A53 seamless steel pipe

A53 Chemical components


ASTM A53 seamless steel pipe
Chemical components
Seamless steel pipe (SMLS) is formed by drawing a solid billet over a piercing rod to create the hollow shell, without
Standard Trade Mark C Si Mn P S Cu Ni Mo Cr V
welding or seam. It is suitable for bending and cutting. The advantage of seamless steel is the ability of withstanding
higher pressure.ASTM A53 specification also covers seamless steel pipe. The pipe is intended for pressure and A ≤0.25 / ≤0.95 ≤0.05 ≤0.045 ≤0.40 ≤0.40 ≤0.15 ≤0.40 ≤0.08
mechanical applications and is also acceptable for ordinar y uses in oil, gas, steam, water and air lines. It is suitable for
ASTM A53
welding, bending and flanging. ≤0.30 / ≤1.2 ≤0.05 ≤0.045 ≤0.40 ≤0.40 ≤0.15 ≤0.40 ≤0.08
B

A53 Mechanical property

Standard: ASTM A53, Type S, Grade B Tensile strength (Mpa) Yield Strengt(Mpa) Elongation(%)
Dimension: Sch40 /Sch80 as ASME B36.10M
Application: Fire main pipe, fire pump pipe,
fire standpipe, fire sprinkler branch pipe , ≥330 ≥205 ≥29.5
Black and red seamless pipe is available
≥415 ≥240 ≥29.5

Pipe Fittings

Outside Diameter and Wall Thickness(American Standard ANSI B36.10 B36.19M)

Nominal Wall Thickness


Galvanized Steel Pipes Galvanized Steel Elbow 90° Galvanized Steel Elbow 90° Galvanized Steel Tee
(Welded Type) (Threaded Type) (Welded Type)

1/8 6 10.3 1.24 -- -- -- 1.73 1.73 1.73 -- 2.41 2.41 2.41 -- -- -- -- --


1/4 8 13.7 1.65 -- -- -- 2.24 2.24 2.24 -- 3.02 3.02 3.02 -- -- -- -- --
3/8 10 17.1 1.65 -- -- -- 2.31 2.31 2.31 -- 3.20 3.20 3.20 -- -- -- -- --
1/2 15 21.3 2.11 -- -- -- 2.77 2.77 2.77 -- 3.73 3.73 3.73 -- -- -- 4.78 7.47
3/4 20 26.7 2.11 -- -- -- 2.87 2.87 2.87 -- 3.91 3.91 3.91 -- -- -- 5.56 7.82
1 25 33.4 2.77 -- -- -- 3.38 3.38 3.38 -- 4.55 4.55 4.55 -- -- -- 6.35 9.09
1 1/4 32 42.2 2.77 -- -- -- 3.56 3.56 3.56 -- 4.85 4.85 4.85 -- -- -- 6.35 9.70
1 1/2 40 48.3 2.77 -- -- -- 3.68 3.68 3.68 -- 5.08 5.08 5.08 -- -- -- 7.14 10.15
2 50 60.3 2.77 -- -- -- 3.91 3.91 3.91 -- 5.54 5.54 5.54 -- -- -- 8.74 11.07
2 1/2 65 73.0 3.05 -- -- -- 5.16 5.16 5.16 -- 7.01 7.01 7.01 -- -- -- 9.53 14.02
3 80 88.9 3.05 -- -- -- 5.49 5.49 5.49 -- 7.62 7.62 7.62 -- -- -- 11.13 15.24
Galvanized Steel Galvanized Steel
3 1/2 90 101.6 3.05 -- -- -- 5.74 5.74 5.74 -- 8.08 8.08 8.08 -- -- -- -- -- Galvanized Steel Tee Galvanized Steel Cross Tee
Bell Reducer Bell Reducer
(Threaded Type) (Threaded Type)
4 100 114.3 3.05 -- -- -- 6.02 6.02 6.02 -- 8.56 8.56 8.56 -- 11.13 -- 13.49 17.12 (Welded Type) (Welded Type)
5 125 141.3 3.40 -- -- -- 6.55 6.55 6.55 -- 9.53 9.53 9.53 -- 12.7 -- 15.88 19.05
6 150 168.3 3.40 -- -- -- 7.11 7.11 7.11 -- 10.97 10.97 10.97 -- 14.27 -- 18.26 21.95
8 200 219.1 3.76 -- 6.35 7.04 8.18 8.18 8.18 10.31 12.70 12.70 12.70 15.09 18.26 20.62 23.01 22.23
10 250 273.1 4.19 -- 6.35 7.8 9.27 9.27 9.27 12.70 12.70 12.70 15.09 18.26 21.44 25.4 28.58 25.4
12 300 323.9 4.57 -- 6.35 8.38 9.53 9.53 10.31 14.27 12.70 12.70 17.48 21.44 25.4 28.58 33.32 25.4
14 350 355.6 4.78 6.35 7.92 9.53 -- 9.53 11.13 15.09 -- 12.70 19.05 23.83 27.79 31.75 35.71 --
16 400 406.4 4.78 6.35 7.92 9.53 -- 9.53 12.7 16.66 -- 12.70 21.44 26.19 30.96 36.53 40.49 --
18 450 457.2 4.78 6.35 7.92 11.13 -- 9.53 14.27 19.05 -- 12.70 23.83 29.36 34.96 39.67 45.24 --
20 500 508.0 5.54 6.35 9.53 12.7 -- 9.53 15.09 20.62 -- 12.70 26.19 32.54 38.1 44.45 50.01 --
22 550 558.8 5.54 6.35 9.53 12.7 -- 9.53 -- 22.23 -- 12.70 28.58 34.93 41.28 47.63 53.98 --
24 600 609.6 6.35 6.35 9.53 14.27 -- 9.53 17.48 24.61 -- 12.70 30.96 38.89 46.02 52.37 59.54 --
26 650 660.4 -- 7.92 12.7 -- -- 9.53 -- -- -- 12.70 -- -- -- -- -- -- Galvanized Steel Slip Flexible Mechanical
Galvanized Steel End Cap Galvanized Steel Blind Flange
700 -- 7.92
On Flange Grooved Coupling
28 711.2 12.7 15.88 -- 9.53 -- -- -- 12.70 -- -- -- -- -- --

57 58
Foam Fire Extinguishing System Fire Hose Rack & Reel

Foam Fire Extinguishing System


Fire hose reel
Foam Bladder Tank is to provide foam solution for fire foam system. It is mainly consist of pressure tank , bladder,
proportioner, control valves, pressure gauge and pipelines. High-pressure water is needed to swap out foam
concentrate(stored in bladder in the tank) from the tank as a certain proportion. Foam concentrate then mix with Specification
pressurized water and form foam solution. The concentrate is discharged from the tank by incoming water applying
Material: Rubber
pressure to the bladder. This applied energy is transferred to the concentrate,supplyying pressurized concentrate to the
proportioner. (Proportioners are separate items described on a separate data sheet.) For bladder is separated from the Length: 30m
water that it can be utilized next time if not finished.Besides, there is feed inlet to refill or rehange foam concentrate.
Size: DN19 (3/4") & DN25 (1")
With valve
With nozzle
Swing automatic and manual for options

Fire hose rack

Horizontal type Vertical type


Specification

Material: Canvas
High Water Length: 30m

Size: DN40 (1.5") &DN65 (2 (1/2"))


Coupling: aluminum x 2pcs
Nozzle: brass or plastic for options

Right angle valve: brass


With hose rack

Features

Big flow pressure range and small pressure loss.

Widely used both in mid-multiples and low multiples foam extinguishing system.
Hose Rack Hose Adapter Right Angle Valve
Two types: horizontal and vertical.

Hose Nozzle Hose Coupling


Fire Hose
Foam Monitor Foam Chamber

59 60
Hose Accessories & Fire Blanket Sprinkler Series

Embedded & Wall-mounted type Cabinet


Customizable size and design cabinet for options

Fire Hose Reel Cabinet Fire Hose Reel Cabinet Fire Hose Cabinet Extinguisher Cabinet

Fire Blanket

Fire Blanket Box Package Fire Blanket Plastic Package

Fire Blanket Box Package


Glass bulb type fire sprinkler
Model Number Fire Blankets Size Net weight (pcs) Gross weight (pcs) Quantity(pcs of box)/Size Type Pendent Upright Sidewall
AW-FB101 1m*1m 0.45kg 0.7kg 20pcs/ 52 ×34 ×21cm

AW-FB103 1.2m*1.2m 0.64kg 0.9kg 20pcs/ 52 ×34 ×21cm

AW-FB105 1.5m*1.5m 1.10kg 1.3kg 15pcs/ 52 x34 ×21cm

AW-FB107 1.2m*1.8m 0.93kg 1.35kg 15pcs/ 52 x34×21cm

AW-FB109 1.8m*1.8m 1.39kg 1.8kg 10pcs/ 42 ×34×21cm

Fire Blanket Plastic Package


Model Number Fire Blankets Size Net weight (pcs) Gross weight (pcs) Quantity(pcs of box)/Size

AW-FB102 1m*1m 0.45kg 0.5kg 30pcs/ 42 ×34 ×21cm

AW-FB104 1.2m*1.2m 0.64kg 0.7kg 20pcs/ 42 ×34 ×21cm

AW-FB106 1.5m*1.5m 0.98kg 1.1kg 15pcs/ 42 x34 ×21cm

AW-FB108 1.2m*1.8m 0.95kg 1.05kg 15pcs/ 42 x34×21cm

AW-FB110 1.8m*1.8m 1.39kg 1.45kg 10pcs/ 42 ×34×21cm

61 62
International Certificates and Patents International Certificates and Patents

63 64
International Certificates and Patents International Certificates and Patents

65 66

You might also like