S1.03 - Structural Symbols and Notations
S1.03 - Structural Symbols and Notations
THE FOLLOW ING MATERIAL IDENTIFICATION SYMBOLS MAY BE USED IN THE SECTIONS AND DETAILS:
THE FOLLOW ING SYMBOLS MAY BE USED THROUGHOUT THE PLANS. THE FOLLOW ING STRUCTURAL ELEMENT TAGS, USED IN CONJUNCTION W ITH THE FOLLOW ING STRUCTURAL ANNOTATIONS MAY APPEAR ON THE FOUNDATION
SCHEDULES, MAY APPEAR ON THE DRAW INGS: PLANS:
SLOPE EDGE HORIZONTAL
DIMENSION Bxx DENOTES SLAB BOTTOM REINFORCEMENT TYPE "xx" 999 Peachtree St., NE Tel Tel 404.507.1000
12 W 14x90 COLUMN SIZE OR MARK (IF PROVIDED)
SLOPE 5 BMxx DENOTES CONCRETE BEAM TYPE "xx"
BPxx DENOTES BASE PLATE TYPE "xx" F7.0 SPREAD, STRIP, OR COMBINED FOOTING MARK BP3 BASE PLATE MARK (IF PROVIDED) Suite 1400 Fax Fax 404.507.1001
DOW N VERTICAL
Cxx DENOTES COLUMN TYPE "xx" C12 COLUMN MARK (IF PROVIDED) Atlanta, GA 30309
DIMENSION
CFxx DENOTES CONTINUOUS FOOTING TYPE "xx" +640'-0" TOP OF FOOTING ELEVATION (IF PROVIDED) United States
ALUMINU CAST-IN-PLACE EARTH EARTH EXISTING GRAVEL GROUT SLOPE TRANSITION RAMP SLOPE SLOPE PITCH
M CONCRETE (UNDISTURBED)CONSTRUCTION DPxx DENOTES DRILLED PIER TYPE "xx" THE FOLLOW ING STRUCTURAL ANNOTATIONS MAY APPEAR ON THE STEEL FRAMING
INDICATOR INDICATOR INDICATOR
EPxx DENOTES EMBEDDED PLATE TYPE "xx" PLANS. ALL LOADS INDICATED ARE FACTORED:
SYMBOL SYMBOL SYMBOL
Fxx DENOTES SPREAD FOOTING TYPE "xx"
FPxx DENOTES FRAMING PENETRATION TYPE "xx"
LEFT END VERTICAL SHEAR
GBxx DENOTES GRADE BEAM TYPE "xx"
SIZE OF STEP SIZE OF STEP REACTION (IN KIPS)
MW xx DENOTES CMU W ALL TYPE "xx"
(IF PROVIDED) (IF PROVIDED) Pxx DENOTES PIER TYPE "xx" BEAM SIZE
MASONR POLYSTYRENE RIGID ROCK STEEL
STRUCTURAL W OOD 8" PCxx DENOTES PILE OR PIER CAP TYPE "xx"
6" Sxx DENOTES ONE-W AY SLAB TYPE "xx" PIER MARK BEAM CAMBER
Y INSULATION PRECAST
CONCRETE SRxx DENOTES HEADED SHEAR STUD REINFORCEMENT TYPE "xx" P2 COLUMN MARK (IF PROVIDED) R25 W 16x26 C=1.25 R30 RIGHT END VERTICAL SHEAR
SFxx DENOTES STRIP FOOTING TYPE "xx" C12 TOP OF PIER ELEVATION (IF PROVIDED) REACTION (IN KIPS)
THE FOLLOW ING MATERIAL IDENTIFICATION SYMBOLS MAY BE USED IN THE PLANS: STEP STEP TO SLOPE RIDGE
Txx DENOTES SLAB TOP REINFORCEMENT TYPE "xx" +640'-0" ESTIMATED PIER TIP ELEVATION (IF PROVIDED)
TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND
INDICATOR INDICATOR INDICATOR SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES
W Fxx DENOTES W ALL FOOTING TYPE "xx" ~600'-0"
SYMBOL SYMBOL SYMBOL REQUIRED ROCK SOCKET (IF PROVIDED) NON-COMPOSITE BEAM
20'-0" RS
1200K COLUMN UNFACTORED REACTION IN KIPS (IF PROVIDED)
30
W ITH 90° HOOK W ITH 180° HOOK PENETRATION EACH PAN SIDE HORIZONTAL). REFER TO DETAILS FOR ADDITIONAL INFORMATION ON LOADING OF SLOPED Date Description
W ELDED W IRE REINFORCEMENT CONT CONTINUOUS PERP PERPENDICULAR
SYMBOL COORD COORDINATE PG PLATE GIRDER MEMBERS.
30
COV COVER PL PLATE 04.12.2019 BOND VALIDATION PRICING PACKAGE
STEEL JOIST LINE SYMBOL CPRS COMPRESSIBLE PLF POUNDS PER LINEAR FOOT FOR ALL LOADING, REACTIONS ARE TO BE APPLIED AT THE CENTERLINE OF THE MEMBER AT THE
FORCE W ORK POINT, UNLESS NOTED OTHERW ISE. IF ONLY A SINGLE VALUE IS SHOW N, THE LOAD SHALL 08.30.2019 DESIGN DEVELOPMENT PACKAGE
(KIPS) CTRS CENTERS PJP PARTIAL JOINT PENETRATION
db BAR DIAMETER PRELIM PRELIMINARY BE ASSUMED TO ACT IN BOTH DIRECTIONS W ITH EQUAL MAGNITUDE. FOR AXIAL LOAD REACTIONS, 12.02.2019 GMP PACKAGE
OPENING LINE SYMBOL 50 DBA DEFORMED BAR ANCHOR PROP PROPERTY A POSITIVE VALUE INDICATES TENSION. FOR VERTICAL MOMENTS, A POSITIVE VALUE W ILL CAUSE 12.02.2019 PERMIT PACKAGE ONE
FPx COMPRESSION IN THE TOP OF THE BEAM AND TENSION IN THE BOTTOM.
DCW DEMAND CRITICAL W ELD PSF POUNDS PER SQUARE FOOT 02.03.2020 PERMIT PACKAGE TWO
DET DETAIL PSI POUNDS PER SQUARE INCH REINFORCING STEEL NOTED IN PLAN SHALL BE LOCATED
STEEL FRAMING PASS-THROUGH BRACE/KICKER DIA DIAMETER PT POST-TENSION(ED) 4-#4x5'-0" TOP 1 05.04.2020 PERMIT PACKAGE THREE
ACCORDING TO PLAN NOTES, TYPICAL VIEW S, AND
VIEW REFERENCE SYMBOLS PENETRATION FORCE SYMBOL DIRECTION DIM DIMENSION QTY QUANTITY SCHEDULES. HOOKS ARE INDICATED IN PLAN W HERE
VERTICAL AXIS 2 01.29.2020 ISSUED FOR CONSTRUCTION
INDICATOR SYMBOL DW A DEFORMED W IRE ANCHOR R REACTION REQUIRED FOR NON-SCHEDULED REINFORCING STEEL. HORIZONTAL SHEAR VERTICAL SHEAR REACTION (R)
DW G DRAW ING RAD RADIUS W HERE HOOKS ARE SHOW N, LENGTHS PROVIDED DO NOT REACTION (H) OCCURS ALONG VERTICAL AXIS
EA EACH REF REFERENCE INCLUDE HOOK.
THESE FOLLOW ING SYMBOLS MAY BE USED THROUGHOUT THE DRAW INGS TO REFER TO EF EACH FACE REINF REINFORCEMENT HORIZONTAL MOMENT REACTION (MH)
OTHER VIEW S: 50 EJ EXPANSION JOINT REM REMAINDER
EPx A SINGLE ARROW ED LINE INDICATES THE EXTENT OVER OCCURS ABOUT VERTICAL AXIS
EL ELEVATION REQD REQUIRED Tx
DETAIL NUMBER W HICH THE REINFORCING STEEL IS TO BE DISTRIBUTED
REFERENCE ELEV ELEVATOR REV REVISION W ITH AN EQUAL SPACING BETW EEN BARS. TORSION AXIAL REACTION (P) ALONG MEMBER
OR LETTER
OBJECT EMBED EMBEDMENT, EMBEDDED RS ROCK SOCKET REACTION (T)
0
A ENGR ENGINEER RTU ROOF TOP UNIT VERTICAL MOMENT REACTION (M)
EPx
SHEET NUMBER S-302 EQ EQUAL SC SLIP CRITICAL
EQUIP EQUIPMENT SCHED SCHEDULE(D) REFERENCE LINE OR OBJECT W HERE BEAM BEAM
EQUIV EQUIVALENT SDS SELF-DRILLING SCREW REINFORCING STOPS SECTION ELEVATION
DETAIL EW EACH W AY SECT SECTION
NUMBER OR A AREA OR CONNECTION W ITH MOMENT CONNECTION TO
EXIST EXISTING SHT SHEET
LETTER ITEM BEING PASS THROUGH FORCE CONNECTION (NON- CONCRETE W ITH SIM SIMILAR
S-302 EXP EXPANSION A DOUBLE ARROW ED LINE INDICATES THAT THE
DETAILED SEISMIC) EMBEDDED PLATE #4x20'-0" BOTTOM
EXT EXTERIOR SLBB SHORT LEG BACK TO BACK REINFORCING STEEL IS TO BE PROVIDED IN EACH
SHEET NUMBER FAB FABRICATE SLRS SEISMIC LOAD RESISTING SYSTEM BARS @ 12" DIRECTION UNTIL ONE OF THE FOLLOW ING OCCURS:
f'c= 28 DAY CONCRETE STRENGTH= SOG SLAB-ON-GRADE
FRAMING DETAIL f'm= 28 DAY MASONRY STRENGTH= SPA SPACING
ELEVATION SYMBOL REFERENCE 1. AN EDGE OF SLAB
FD FLOOR DRAIN SPEC SPECIFICATION 2. A SIGNIFICANT CHANGE IN THE SLAB
SYMBOL SPRT SUPPORT R25 W 16x26 C=1.25 R30
FDTN FOUNDATION GEOMETRY
FF FAR FACE SQ SQUARE 3. OTHER REINFORCING STEEL OF A SIMILAR <+2
(18)
1/2>
REFERENCE REFERENCE FIN FINISH(ED) SS STAINLESS STEEL NATURE IS SHOW N TOP OF STEEL ELEVATION RELATIVE
OBJECT OBJECT FLR FLOOR SSLP SHORT-SLOTTED HOLE PARALLEL
TO TYPICAL TOP OF STEEL ELEVATION.
FS FAR SIDE SSLT SHORT-SLOTTED HOLE TRANSVERSE
A POSITIVE VALUE INDICATES THE
CONNECTION W ITH TW O CONNECTION W ITH CONNECTION W ITH FULL- FTG FOOTING STD STANDARD
DETAIL DETAIL NUMBER STEEL BEAM IS ABOVE THE TYPICAL
COLUMNS OF BOLTS DOUBLE SHEAR PLATE DEPTH SHEAR PLATE FUT FUTURE STIF STIFFENER
NUMBER OR OR LETTER ELEVATION.
FV FIELD VERIFY STIR STIRRUP SHEAR W ALL
LETTER A A A Fy= YIELD STRENGTH= STL STEEL DESIGNATION
GALV GALVANIZE(D) STRUC STRUCTURE, STRUCTURAL
S-302 S-302 S-302 OPENING IN W ALL
X GEN GENERAL SW SHEAR W ALL
GR GRADE SYMM SYMMETRIC, SYMMETRICAL SW 3
SHEET NUMBER SHEET NUMBER H HORIZONTAL REACTION T TORSION
HGR HANGER TC TOP OF COLUMN
OVERALL SECTION PARTIAL X HORIZ HORIZONTAL THD THREADED
SYMBOL SECTION HSA HEADED STUD ANCHOR TO TOP OF
SYMBOL HSS HOLLOW STRUCTURAL SECTION TOC TOP OF CONCRETE
CONNECTION W ITH CONNECTION W ITH SPECIAL ID INSIDE DIAMETER TOM TOP OF MASONRY
GUSSET AND W ELDED GUSSET CONNECTION INFO INFORMATION TOS TOP OF STEEL, TOP OF SLAB
INT INTERIOR TRANS TRANSVERSE BRACES ABOVE OR BELOW ARE
FLANGES (TYPE X) INDICATED BY HIDDEN LINES.
UNIVERSAL SYMBOLS JT
K
JOINT
KIPS (1000 LBS)
TYP
UNO
TYPICAL
UNLESS NOTED OTHERW ISE REFER TO BRACED FRAME
KSF KIPS PER SQUARE FOOT VERT VERTICAL ELEVATIONS FOR CONFIGURATION.
DRAPES AT TENDON ENDS DRAPES AT SUPPORTS ARE
KSI KIPS PER SQUARE INCH WF W IDE FLANGE ARE PROVIDED IN LINE PROVIDED ABOVE OR TO THE
THESE FOLLOW ING SYMBOLS MAY BE USED THROUGHOUT THE LBS POUNDS WP W ORK POINT W ITH TENDONS LEFT OF TENDONS
DRAW INGS: Ld DEVELOPMENT LENGTH WS W ATERSTOP
LLBB LONG LEG BACK TO BACK WT W EIGHT JOIST
REVISION NUMBER ELEVATION OF REFERENCE WWR W ELDED W IRE REINFORCEMENT 270K 6.5" 351K
OBJECT OR LOCATION XS EXTRA STRONG 4" 4" LINE OF BRIDGING
OR LETTER 1.5" 1.5"
XXS DOUBLE EXTRA STRONG
2 10'-4" CONNECTION W ITH BEAM SPLICE CONNECTION MOMENT
W ELDED TOP (SHEAR ONLY) CONNECTION
AREA OR ITEM TOP OF SLAB
FLANGE (SEISMIC)
BEING REVISED REFERENCE OBJECT DRAPES AT MIDSPAN ARE EFFECTIVE TENDON FORCES (AFTER LOCATION OF CROSS-BRIDGING
OR LOCATION PROVIDED BELOW OR TO ALL LOSSES) ARE PROVIDED IN KIPS (IF PROVIDED)
ROUGH OUTLINE OF UNIT THE RIGHT OF TENDONS FOR CONCENTRATED TENDON
GROUPS AND IN KIPS PER FOOT FOR
REVISION CLOUD ELEVATION
SUPPORT CENTERLINE UNIFORM TENDONS. DIFFERENT
SYMBOL DESIGNATION SYMBOL BOTTOM FLANGE BRACE
XXX-x UNIT NAME (IF PROVIDED) VALUES MAY APPEAR IN DIFFERENT
3,500# SPANS OF THE SAME TENDON. IF
BELOW MAXIMUM TOTAL ONLY ONE VALUE IS GIVEN, IT
GRID LABEL STEEL BEAM
ALLOW ABLE W EIGHT OF APPLIES FOR THE ENTIRE LENGTH OF
UNIT OR EQUIPMENT THE TENDONS.
INCLUDING W EIGHT OF
B CURB
WP MECHANICAL UNIT OR IF PROVIDED, INDICATES
OTHER EQUIPMENT UNIT IS HANGING BELOW INDICATOR SYMBOL POINTS AW AY
FLOOR OR ROOF FROM BOTTOM FLANGE OF BEAM
BEING BRACED
REFERENCE GRID W ORK POINT
INDICATOR SYMBOL SYMBOL BRACING ATTACHED DIRECTLY
TO FLOOR SYSTEM
Seal / Signature
ISSUED FOR
CONSTRUCTION
BIM 360://S06-18009-00 GWCCA Hotel/S06-18009-00 - BldgABC - v2019.rvt
Project Name
GWCC HOTEL
Project Number
13.2749.000
Description
Scale
1/8" = 1'-0"
1/29/2021 8:32:50 AM
S1.03
© 2021 Gensler