0% found this document useful (0 votes)
43 views4 pages

Vortex Check Sheet

The vortex meter check sheet summarizes specifications and field data collected during an inspection on December 13, 2022. Parameters were recorded with and without flow, including flow rate of 3086-3104 nm3/h, temperature of 28.3°C, and pressure of 1.7 bar. Converter settings and calibration details were also documented, such as meter size of 6 inches and meter factor of 10.254.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views4 pages

Vortex Check Sheet

The vortex meter check sheet summarizes specifications and field data collected during an inspection on December 13, 2022. Parameters were recorded with and without flow, including flow rate of 3086-3104 nm3/h, temperature of 28.3°C, and pressure of 1.7 bar. Converter settings and calibration details were also documented, such as meter size of 6 inches and meter factor of 10.254.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

Vortex Meter Check Sheet

Date 13/12/2022
Checked by Ratno
Specifications
Vortex Model No. AX2222-150SFA-LED1ASB-MCCC
Inline Insertion Manufactured Date Aug-15
Field Data
Power Supply Voltage 24 V
Installed Location Indoor Outdoor Ambient Temp C/F Piping Material Metal
Metal w/ Liner Plastic Pipe
Type of Pipe SUS304/6" Schedule SCH40 Straight Pipe Length (downstream side)
(upstream side)
Process Fluid
Fluid Name N2 Fluid Temp 28.3 'C Flow Rate 0~6000 nm3/h

Converter Parameters
Record the values from the RUN Menu with meter installed in order to determine the
operating state of the meter
With Flow With No Flow
Flow= 3086~3104 nm3/h
Temp = 28.3 'C
Pressure = 1.7 bar (G)
Density = -
Error Msgs = - -

Record the below values from Hiden Diagnostics Menu with


the meter installed (use password 16363)
With Flow With No Flow
f= 114.2 ~ 129.5
fi = 142 ~ 166
A= 0.006 ~ 0.009
A1 = 512
A2 = 484 ~512
A3 = 65 ~ 81
A4 = 7 ~ 11
V= 65.8 ~ 69.6
Ck = 3.03 ~ 3.93
Lvl = 378 ~ 415
Adj. Filter = 0
Iso Poswer Volts = 2.9

Record the following from the Calibration Menu

Meter Size/Pipe ID = 6 inch


Meter Factor = 10.254
Vortex Coeff Ck = 2.5
Low Flow Cutoff = 20
Serial Number = 2628587761

Form QF 7.5.1
C/F Piping Material Metal

Pipe Length (downstream side)

0~6000 nm3/h

Additional Process Fluid Data


Gas
Compensation
Spec.Gravity
Flowing Viscocity cP
Liquid
Density
Viscocity cP

Flow Direction
(FD)
(FD)
(FD)
(FD)
Form QF 7.5.1-2