Fan Cat 2
Fan Cat 2
Fan Cat 2
May 1999
Series 4000
Centrifugal BCI Fans
Industrial Duty
Design 4170 • Model 45
Design 4270 • Model 40
Design 4370 • Model 30
CML Northern Blower Inc. is one of
the largest industrial fan companies
in North America. In all that we do we
are committed to the construction of
an excellent product and the provi-
sion of outstanding customer serv-
ice.
Series 4000
Centrifugal BCI Fans
The Series 4000 Centrifugal Backward Curved Industrial (BCI) fans are highly Design Features 2
efficient with stable operation suited for a wide range of rigorous industrial applica-
tions. Due to the broad capabilities of the Series 4000 fan, this bulletin contains only General Information 3
limited performance information. Further information on extended performance and
custom fans is available from your Northern Blower sales representative. Accessories 4
Selection 6
Industrial supply and exhaust:
Thermal Oxidizers Performance Data 8
Baghouses
Scrubbers Dimensions 29
Forced Draft
Induced Draft Fan Geometry 32
Combustion Air Supply
Pulp and Paper Machines Sound Pressure 33
Drying Kilns
Fan Arrangements 35
1
Design Features
Shaft
Turned ground and polished or fully
machined to close tolerance.
Shaft Seal
Used to reduce leakage through the
shaft hole in the housing.
Heavy Duty
Structural Bearing Pedestal
Housing
Rugged heavy gauge all welded
steel housing with substantial
framing sections for maximum
rigidity. Standard features include
flanged outlet, shaft seal and gasketted
Balancing
housing split on sizes 3650 and larger.
Wheel and shaft assemblies are
dynamically balanced to ANSI S2.19-
1989 specifications and are interference
fit on all Models.
2
General Information
The performance and limits of Designs 4170 Model 65, 4270 Model
55 and 4370 Model 45 fans can be determined using Northern
Blower's FanFinder™ and FanQuote™ computer programs.
Temperatures
Operating Temperatures to 800°F. See Table 2, Page 6
Series 4000
Centrifugal BCI Wheel
The Northern Blower Backward Curved Industrial (BCI) wheels diameter. The performance for Design 4570 is in Bulletin 4500.
have a single camber, backward curved design for high
operating efficiency and a non-overloading horsepower The nominal diameters available for the Models in this bulletin
characteristic. The blades are formed from heavy gauge single are 24-1/2" to 80-3/4". The impellers are available from 95 to
thickness material. 110% of nominal diameter in a fixed width housing.
The fans are offered in a family of wheel designs with Performance for these diameters is determined using Northern
overlapping performance ranges. The backward curved wheels Blower's FanFinder™ computer program.
progress from large diameters with narrow blades to small
diameters with wide blades, so that a perfectly sized fan can be
supplied for the job. Performance tables are provided in this Standard Features
bulletin for Designs 4170, 4270 and 4370 at 110% of nominal • Heavy Duty Ball or Split Pillow Block
Spherical Roller Bearings
• Integral Bearing Pedestal
• Punched Flanged Outlet
▼
• Shaft Seal
• Wheel With Anti-thrust Vanes
• Horizontal Split Housing—Size
3650 and up
• Hinged Flush Mounted
Access Door
• Slip Fit Inlet
3
Accessories
4
Accessories
5
Selection
Fan Selection at
Elevated Temperature and Altitude
Fan Selection Tables Table 2
Ratings shown in the Performance Tables are based on
High Temperature Operating Limits
standard air density of .075 pounds per cubic foot at the fan
Without With
inlet. Standard air is dry air at 70°F and 29.92" Hg barometric Arrangement
Cooling Wheel Cooling Wheel
pressure. When air density varies from standard, due to 1 SW 300°F 800°F
temperature or altitude changes, the Air Density Correction
8 SW * 300°F 800°F
Factor from Table 1 is applied. Refer to the sample selection
9F SW 300°F 650°F
that follows.
*Refer to bulletin 4000 for direct drive fan selection criteria.
Note that data in the selection tables does not include the
effects of accessories such as inlet dampers, outlet dampers,
Table 3
screens, or other components in the air stream.
Arr. 1, 9F Wheel and Shaft Maximum Speeds at 70°F
High Temperature High Strength Low Alloy Steel, SS304L and SS316L
Fans selected for high temperature service must fall within the Size Design 4170 Design 4270 Design 4370
limits for a particular arrangement as shown in Table 2. For Model 45 Model 40 Model 30
selection, both fan performance and physical operating limits 2450 3543 3402 3047
must be corrected. Refer to the sample selection on the 2700 3215 3087 2765
3000 2894 2778 2489
following page.
3300 2631 2525 2262
3650 2378 2283 2045
4025 2157 2071 1855
Table 1
4450 1951 1873 1678
Air Density Correction Factor 4900 1772 1701 1524
Air 5425 1600 1536 1376
Elevation (Feet) above Sea Level
Temp 6000 1447 1389 1244
°F 0 500 1000 2000 3000 4000 5000 6600 1315 1263 1131
-40° .79 .81 .82 .85 .88 .92 .95 7300 1189 1142 1023
0° .87 .88 .90 .93 .97 1.00 1.04 8075 1075 1032 925
40° .94 .96 .98 1.01 1.05 1.09 1.13
70° 1.00 1.02 1.04 1.08 1.12 1.16 1.20
100° 1.06 1.08 1.10 1.14 1.18 1.22 1.27 Table 4
140° 1.13 1.15 1.17 1.22 1.26 1.31 1.36
Safe Speed Deration Factors
180° 1.21 1.23 1.25 1.30 1.35 1.40 1.45
High Strength Stainless Steel Stainless Steel
200° 1.25 1.27 1.29 1.34 1.39 1.44 1.50 Temp F
Low Alloy Steel 304L 316L
250° 1.34 1.36 1.39 1.44 1.49 1.55 1.61
-50 to 70 1.00 1.00 1.00
300° 1.43 1.46 1.49 1.54 1.60 1.66 1.72 100 0.99 0.99 0.98
350° 1.53 1.56 1.58 1.64 1.71 1.77 1.84 200 0.97 0.96 0.91
400° 1.62 1.65 1.68 1.75 1.81 1.88 1.95 300 0.96 0.92 0.87
450° 1.72 1.75 1.78 1.85 1.92 1.99 2.06 400 0.95 0.88 0.83
500° 1.81 1.84 1.88 1.95 2.02 2.10 2.18 500 0.94 0.84 0.80
600° 2.00 2.04 2.07 2.15 2.23 2.32 2.40 600 0.92 0.81 0.77
700° 2.19 2.23 2.27 2.35 2.44 2.53 2.63 700 0.87 0.78 0.74
800° 2.38 2.42 2.46 2.56 2.65 2.75 2.86 800 0.68 0.75 0.72
6
Selection
Drive Configurations
7
Performance Data
8
Performance Data
9
Performance Data
10
Performance Data
11
Performance Data
12
Performance Data
13
Performance Data
14
Performance Data
15
Performance Data
16
Performance Data
17
Performance Data
18
Performance Data
19
Performance Data
20
Performance Data
21
Performance Data
22
Performance Data
23
Performance Data
24
Performance Data
25
Performance Data
26
Performance Data
27
Performance Data
28
Dimensions
G* L B C HH HH
JJ SPACES
@ 4" CTRS GG
K KK
(KEYWAY) X A
MM
*
FI.D.
LL SPACES
@ 4" CTRS
D
H
L
FAN C
KK FF
M W J E
NN - DIA., PP - NO. HOLES
FRONT ELEVATION DRIVE SIDE ELEVATION
*DIMENSIONS FOR OPTIONAL FLANGED INLET ARRANGEMENT 1 OUTLET FLANGE DETAIL
S
Q
E
Q CW360 UB CW45 TAU CW135 TAD CW180 DB CW270 BH CW315 BAU
S
FOUNDATION (PLAN)
FAN Max
M N P Q R S T W X AA BB CC DD EE FF GG HH JJ KK LL MM NN PP
SIZE Mtr. 9F
2450 2-1/2 10-3/16 6-9/16 14-1/8 20-1/2 17-1/2 5/8 10-3/8 22-5/8 20-13/16 17-3/16 32-7/8 18-15/16 41 2-11/32 1-3/8 4-9/16 1 4-11/16 4 2-1/2 5/8 18 286
2700 2-1/2 10-11/16 7-1/16 16-1/8 22 19-1/2 5/8 11-3/8 25 22-7/8 18-15/16 35-13/16 20-7/8 44-11/16 2-1/2 1-3/8 5-1/16 1 5-7/8 4 2-1/2 5/8 18 286
3000 2-1/2 11-3/8 7-3/4 17-5/8 22 21 5/8 12-3/4 27-7/8 25-1/2 21-1/16 38-13/16 23-1/4 48-5/16 2-11/16 1-3/8 5-3/4 1 5-5/16 5 2-1/2 5/8 20 326
3300 2-1/2 12 8-3/8 19-3/8 22-1/4 22-3/4 5/8 14 30-5/8 28 23-1/8 41-7/8 25-9/16 51-15/16 2-13/16 1-3/8 4-3/8 2 4-11/16 6 2-1/2 5/8 24 326
3650 3 13-3/4 9-1/2 21-1/4 26-3/8 25 3/4 15-1/2 33-3/4 30-15/16 25-9/16 45-11/16 28-1/4 56-5/8 2-27/32 1-3/8 5-1/8 2 4-1/4 7 2-1/2 5/8 26 365
4025 3 14-1/2 10-1/4 21-1/4 26-3/8 25 3/4 17 37-1/4 34-1/8 28-3/16 49-1/16 31-1/8 60 3-7/16 1-3/4 4-1/4 3 4-3/8 8 3 3/4 30 365
4450 3 15-3/8 11-1/8 23-7/8 27-1/4 27-5/8 3/4 18-3/4 41-1/8 37-11/16 31-1/8 53-5/8 34-3/8 65-1/2 3-9/16 1-3/4 5-1/8 3 4-5/16 9 3 3/4 32 365
4900 4 18-5/16 12-13/16 26-1/8 25-1/2 30-5/8 7/8 20-5/8 45-1/4 41-1/2 34-1/4 58-9/16 37-13/16 71-5/8 3-3/4 1-3/4 4-1/16 4 4-3/8 10 3 3/4 36 404
5425 4 19-7/16 13-15/16 29 30-1/2 33-1/2 7/8 22-7/8 50-1/8 46 37-15/16 64-5/16 41-15/16 77-15/16 3-15/16 1-3/4 5-3/16 4 4-13/16 11 3 3/4 38 404
6000 4 20-5/8 15-1/8 33 31 37-1/2 7/8 25-1/4 55-3/8 50-13/16 41-15/16 70-9/16 46-5/16 85-9/16 4-1/8 1-3/4 4-3/8 5 5-7/16 12 3 3/4 42 404
6600 4 21-7/8 16-3/8 36-3/4 31 41-1/4 7/8 27-3/4 60-7/8 55-7/8 46-1/8 77-1/8 50-15/16 93-3/16 4-3/8 1-3/4 5-5/8 5 4-3/16 14 3 3/4 46 -
7300 4 23-5/16 17-13/16 41-3/4 33 46-1/4 7/8 30-5/8 67-1/4 61-3/4 51 84-5/8 56-5/16 102-7/8 4-19/32 1-3/4 5-1/16 6 5-3/8 15 3 3/4 50 -
8075 6 28-15/16 20-7/16 44-1/4 35-1/2 49-3/4 1 33-7/8 74-3/8 68-5/16 56-3/8 93-3/16 62-1/4 112-1/4 4-29/32 1-3/4 4-11/16 7 4-15/16 17 3 3/4 56 -
*HSLA - High Strength Low Alloy Steel, **SS - SS304L, SS316L
DO NOT USE FOR CONSTRUCTION UNLESS CERTIFIED.
29
Dimensions
G* L B C HH HH
JJ SPACES
@ 4" CTRS GG
K
(KEYWAY) A X KK
MM
*
FI.D.
LL SPACES
@ 4" CTRS
D
H
KK
M W J E
NN - DIA., PP - NO. HOLES
FRONT ELEVATION DRIVE SIDE ELEVATION
*DIMENSIONS FOR OPTIONAL FLANGED INLET ARRANGEMENT 1 OUTLET FLANGE DETAIL
S
Q
E
Q CW360 UB CW45 TAU CW135 TAD CW180 DB CW270 BH CW315 BAU
S
FOUNDATION (PLAN)
FAN Max
L M N P Q R S T W X AA BB CC DD EE GG HH JJ KK LL MM NN PP
SIZE Mtr. 9F
2450 41-1/2 2-1/2 10-1/2 6-7/8 14-1/8 21 17-1/2 5/8 11 21-1/4 20-13/16 17-3/16 32-7/8 18-15/16 40-1/16 1-3/8 4-7/8 1 4 4 2-1/2 5/8 18 286
2700 44 2-1/2 11-1/16 7-7/16 16-1/8 22 19-1/2 5/8 12-1/8 23-3/8 22-7/8 18-15/16 35-13/16 20-7/8 43-5/8 1-3/8 5-7/16 1 5-1/16 4 2-1/2 5/8 18 286
3000 45 2-1/2 11-3/4 8-1/8 17-5/8 22 21 5/8 13-1/2 26-1/8 25-1/2 21-1/16 38-13/16 23-1/4 47-1/8 1-3/8 4-1/8 2 4-7/16 5 2-1/2 5/8 22 326
3300 45-1/2 2-1/2 12-7/16 8-13/16 19-3/8 22-3/8 22-3/4 5/8 14-7/8 28-3/4 28 23-1/8 41-7/8 25-9/16 50-9/16 1-3/8 4-13/16 2 5-3/4 5 2-1/2 5/8 22 326
3650 52-1/2 3 14-3/16 9-15/16 21-1/4 26-3/8 25 3/4 16-3/8 31-3/4 30-15/16 25-9/16 45-11/16 28-1/4 55-3/16 1-3/8 5-9/16 2 5-1/4 6 2-1/2 5/8 24 365
4025 53-1/2 3 15 10-3/4 21-1/4 26-3/8 25 3/4 18 34-7/8 34-1/8 28-3/16 49-1/16 31-1/8 58-7/16 1-3/4 4-3/4 3 5-3/16 7 3 3/4 28 365
4450 56 3 15-15/16 11-11/16 23-7/8 27-1/4 27-5/8 3/4 19-7/8 38-1/2 37-11/16 31-1/8 53-5/8 34-3/8 63-9/16 1-3/4 5-11/16 3 5 8 3 3/4 30 365
4900 58-1/2 4 18-15/16 13-7/16 26-1/8 25-1/2 30-5/8 7/8 21-7/8 42-3/8 41-1/2 34-1/4 58-9/16 37-13/16 69-1/2 1-3/4 4-11/16 4 4-15/16 9 3 3/4 34 404
5425 64-1/2 4 20-3/16 14-11/16 29 30-1/2 33-1/2 7/8 24-3/8 47 46 37-15/16 64-5/16 41-15/16 75-5/8 1-3/4 5-15/16 4 5-1/4 10 3 3/4 36 404
6000 66-1/2 4 21-7/16 15-15/16 33 31 37-1/2 7/8 26-7/8 52 50-13/16 41-15/16 70-9/16 46-5/16 83-5/16 1-3/4 5-3/16 5 5-3/4 11 3 3/4 40 404
6600 68 4 22-3/4 17-1/4 36-3/4 31 41-1/4 7/8 29-1/2 57-1/8 55-7/8 46-1/8 77-1/8 50-15/16 90-9/16 1-3/4 4-1/2 6 4-5/16 13 3 3/4 46 -
7300 71-1/2 4 24-5/16 18-13/16 41-3/4 33 46-1/4 7/8 32-5/8 63-1/8 61-3/4 51 84-5/8 56-5/16 99-13/16 1-3/4 4-1/16 7 5-5/16 14 3 3/4 50 -
8075 80 6 30 21-1/2 44-1/4 35-1/2 49-3/4 1 36 69-3/4 68-5/16 56-3/8 93-3/16 62-1/4 109-1/16 1-3/4 5-3/4 7 4-5/8 16 3 3/4 54 -
*HSLA - High Strength Low Alloy Steel, **SS - SS304L, SS316L
DO NOT USE FOR CONSTRUCTION UNLESS CERTIFIED.
30
Dimensions
G* L B C HH HH
JJ SPACES
@ 4" CTRS GG
K
A X KK
(KEYWAY)
MM
F*I.D.
LL SPACES
@ 4" CTRS
D
H
KK
M W J E
NN - DIA., PP - NO. HOLES
FRONT ELEVATION DRIVE SIDE ELEVATION
*DIMENSIONS FOR OPTIONAL FLANGED INLET ARRANGEMENT 1 OUTLET FLANGE DETAIL
S
Q
E
Q
S CW360 UB CW45 TAU CW135 TAD CW180 DB CW270 BH CW315 BAU
FOUNDATION (PLAN)
FAN Max
L M N P Q R S T W X AA BB CC DD EE GG HH JJ KK LL MM NN PP
SIZE Mtr. 9F
2450 43-1/2 2-1/2 11-1/2 7-7/8 14-1/8 22 17-1/2 5/8 13 23-1/2 23-3/4 18-1/16 35-1/4 20-7/8 41-5/8 1-3/8 5-7/8 1 5-1/8 4 2-1/2 5/8 18 286
2700 44 2-1/2 12-1/8 8-1/2 16-1/8 22 19-1/2 5/8 14-1/4 25-7/8 26-1/8 19-15/16 38-1/2 23 45-3/8 1-3/8 4-1/2 2 4-5/16 5 2-1/2 5/8 22 286
3000 46 2-1/2 13 9-3/8 17-5/8 22 21 5/8 16 28-3/4 29-1/16 22-3/16 41-3/4 25-9/16 48-13/16 1-3/8 5-3/8 2 5-3/4 5 2-1/2 5/8 22 326
3300 47 2-1/2 13-3/4 10-1/8 19-3/8 22-3/8 22-3/4 5/8 17-1/2 31-5/8 31-15/16 24-3/8 45-1/8 28-1/8 52-9/16 1-3/8 4-1/8 3 5-3/16 6 2-1/2 5/8 26 326
3650 54 3 15-11/16 11-7/16 21-1/4 26-3/8 25 3/4 19-3/8 35 35-5/16 26-15/16 49-1/4 31-1/16 57-3/8 1-3/8 5-1/16 3 4-7/8 7 2-1/2 5/8 28 365
4025 55 3 16-5/8 12-3/8 21-1/4 26-1/2 25 3/4 21-1/4 38-1/2 38-15/16 29-11/16 53-9/16 34-1/4 61 1-3/4 4-3/8 4 5 8 3 3/4 32 365
4450 58 3 17-3/4 13-1/2 23-7/8 27-1/4 27-5/8 3/4 23-1/2 42-1/2 43 32-13/16 58-9/16 37-7/8 66-3/8 1-3/4 5-1/2 4 5 9 3 3/4 34 365
4900 60-1/2 3 18-7/8 14-5/8 27-1/8 27-1/2 30-7/8 3/4 25-3/4 46-3/4 47-3/8 36-1/16 63-15/16 41-11/16 72-5/8 1-3/4 4-5/8 5 5-1/8 10 3 3/4 38 404
5425 67-1/2 3 20-5/16 16-1/16 30 33 33-3/4 3/4 28-5/8 51-7/8 52-1/2 40 70-7/16 46-3/16 79-1/4 1-3/4 4-1/16 6 5-11/16 11 3 3/4 42 404
6000 69 4 23-13/16 18-5/16 33 31 37-1/2 7/8 31-5/8 57-3/8 58 44-3/16 77-3/16 51 87-1/16 1-3/4 5-9/16 6 4-7/16 13 3 3/4 46 404
6600 70-1/2 4 25-3/8 19-7/8 36-3/4 31 41-1/4 7/8 34-3/4 63 63-3/4 48-9/16 84-3/8 56-1/8 94-13/16 1-3/4 5-1/8 7 5-1/4 14 3 3/4 50 -
7300 74 4 27-3/16 21-11/16 41-3/4 33 46-1/4 7/8 38-3/8 69-5/8 70-1/2 53-11/16 92-3/4 62 104-7/16 1-3/4 4-15/16 8 4-9/16 16 3 3/4 56 -
8075 83-1/2 6 33-3/16 24-11/16 44-1/4 36 49-3/4 1 42-3/8 77 78 59-3/8 102-1/16 68-9/16 114-1/4 1-3/4 4-15/16 9 4-1/4 18 3 3/4 62 -
*HSLA - High Strength Low Alloy Steel, **SS - SS304L, SS316L
DO NOT USE FOR CONSTRUCTION UNLESS CERTIFIED.
31
Fan Geometry
Notes:
1) Direction of rotation is determined from the drive side of 3) For a fan inverted for ceiling suspension, or side wall
the fan. mounting, the direction of rotation and discharge is
determined when the fan is resting on the floor.
2) Direction of discharge is determined in accordance with the
diagrams. Angle of discharge is referred to the vertical axis
of the fan and designated in degrees from such standard
reference axis. Angle of discharge may be any intermediate
angle as required.
• The sound pressure level ratings shown are decibels referred • The sound pressure levels are based on standard construc-
to 10-12 watt. The ratings were obtained from tests performed tion and operating conditions. All data assumes the ducted
in accordance with AMCA Standard 300. outlet and/or ducted inlet and are of the same material and
thickness as the fan casing and that any expansion joints are
• Sound pressure levels are calculated per AMCA standards acoustically treated.
301 and 303, Installation Type B (free inlet, ducted outlet) and
Type D (ducted inlet, ducted outlet). • Ratings do not include the effect of fan appurtenances, such
as dampers and belt guards, or of air density. The motor and
• Sound pressure levels apply to the normal range of selection any other auxiliary equipment sound are not included.
for high efficiency, as shown in the capacity tables, and are at
5 ft. from the acoustic center of the fan.
• The sound pressure levels shown are for fans with 110% of
nominal diameter wheels. For fans with wheels between 95
and 110% of nominal diameter, use Northern Blower’s
FanFinder™ computer program to determine the sound
levels and performance.
32
Sound Pressure Levels
100 100
96 96
92 92
dBA at 5 ft.
dBA at 5 ft.
88 88
84 84
73 5
7
30 0
66 00
00
80
50
00
50
00
25
80 80
00
33
00
40 50
36
27
24
60
54
25
49
44
76 76
72 72
800 1200 1600 2000 2400 2800 3200 3600 400 600 800 1000 1200 1400 1600 1800
Fan Speed (rpm) Fan Speed (rpm)
84 84
80 80
76 76
dBA at 5 ft.
dBA at 5 ft.
72 72
68 68
50
73 5
66 00
00
30 00
7
50
64 64
00
00
24
80
00
27
33
40 50
25
36
00
60
25
54
44
49
60 60
56 56
800 1200 1600 2000 2400 2800 3200 3600 400 600 800 1000 1200 1400 1600 1800
Fan Speed (rpm) Fan Speed (rpm)
100 100
96 96
92 92
dBA at 5 ft.
dBA at 5 ft.
88 88
84 84
80 80
50
24
60 00
76 76
00
49 5
2
73 7 5
66
44 25
54
00
00
30 00
00
80
50
00
40
50
27
33
36
72 72
800 1200 1600 2000 2400 2800 3200 3600 400 600 800 1000 1200 1400 1600 1800
Fan Speed (rpm) Fan Speed (rpm)
33
Sound Pressure Levels
84 84
80 80
76 76
dBA at 5 ft.
dBA at 5 ft.
72 72
68 68
64 64
60 60
60 00
50
25
00
66
73 5
24
54
00
00
33 0
00
00
7
25
40 0
00
80
5
27
36
30
44
49
56 56
800 1200 1600 2000 2400 2800 3200 3600 400 600 800 1000 1200 1400 1600 1800
Fan Speed (rpm) Fan Speed (rpm)
100 100
96 96
92 92
dBA at 5 ft.
dBA at 5 ft.
88 88
84 84
60 00
66
73 5
25
00
00
7
00
80
54
00
80 80
49
40 0
36 25
33
5
50
44
24 00
00
27
30
50
76 76
72 72
800 1200 1600 2000 2400 2800 3200 3600 400 600 800 1000 1200 1400 1600 1800
Fan Speed (rpm) Fan Speed (rpm)
84 84
80 80
76 76
dBA at 5 ft.
dBA at 5 ft.
72 72
68 68
60 0
0
73 75
25
00
00
64 64
66
00
80
54
00
49
40 5 0
33
50
25
44
36
00
60 60
24 00
30
50
27
56 56
800 1200 1600 2000 2400 2800 3200 3600 400 600 800 1000 1200 1400 1600 1800
Fan Speed (rpm) Fan Speed (rpm)
34
Centrifugal Fan Arrangements
3 SISW c/w BOX 3 SISW c/w IND. PED. 3 SISW c/w BOX & IND. PED. 3 DIDW
For belt drive or direct connection. One For belt drive or direct connection. For belt drive or direct connection. For belt drive or direct connection. One
bearing on each side and supported by Housing is self-supporting. One bearing Housing is self-supporting. One bearing bearing on each side and supported by
fan housing and inlet box. Shaft extending on each side supported by independent on each side and supported by fan housing.
through inlet box. pedestals. independent pedestals with shaft
extending through inlet box.
3 DIDW c/w BOXES 3 DIDW c/w IND. PED. 3 DIDW c/w BOXES & IND. PED 4 SISW
For belt drive or direct connection. One For belt drive or direct connection. For belt drive or direct connection. For direct drive. Impeller overhung
bearing on each side and supported by Housing is self-supporting. One bearing Housing is self-supporting. One bearing on prime mover shaft. No bearings
inlet boxes. Shaft extending through on each side and supported by on each side supported by independent on fan. Prime mover base mounted
inlet boxes. independent pedestals. pedestals with shaft extending through or integrally directly connected.
inlet box.
Reprinted by permission of the Air Movement & Control Association, Inc., 30 West University Drive, Arlington Heights, IL, 60004-1893, U.S.A.
35
Notes
36
®