Test Charges August 2019 Physicochemical External

Download as pdf
Download as pdf
You are on page 1of 4
Customer Service Cell Bio Medical Technology Wing Sree Chitra Tirunal Institute for Medical Sciences & Technology (Institiue of National Importance Under Govt of india) Poojapura, Thiruvananthapuram, Kerala, INDIA ~ 695 012 Tel: 91-471-2340801, 2520307/309; Fax: 2341814; e-mail: [email protected] JEST CHARGES PHYSICO CHEMICAL TESTS -EXTERNAL (w.e.f 1" August 2019) Note: GST and flood cess will be charged as applicable SI. | Name of the test Test method/ | Laboratory | External customers No Sara {in Indian Rupee) per : : | fellowes sample 1 | X-Ray Diffraction Spectrum Approved Division of | 2100 “2. | Microhardness testing protocol Bioceramics | 1100 3 | 1CP-OES 1200 [zelements} 400 each for extra He element) | 4 | Mechanical Testing ‘Approved | =| Tensile Test of dumbbells and rectangular | Protocol based (1500 strips WITHOUT extensometer on AoTty b | Tensile Test of dumbbells and rectangular | 1700 strips WITH extensometer c | Tensile Testing of sheets/plaques/films | writes 1700 (WITHOUT extensometer & requiring sample Division of |__| cutting to dumbbells /rectangular strips ) Polymeric @_ | Tensile Testing of sheets/plaques/films Medical (WITH extensometer & requiring sample Devices cutting to dumbbells /rectangular strips ) Tensile testing of biological tissues e £_| Tensile test (Devices) @ | Compression test ( Cylindrical samples, preferred diameter 2mm and height 4 to 6 mm) Compressi test ( Devices) [5 Impact Testing (IZOD& CHARPY) 1SO 179, ISO 180 | 2250 [6 | Dynamic Mechanical Analysis ~~ Approved eee L Se ele ae protocol lla | a | Analysis of samples from ambient to desired 3600 high temperature fee eee a eee eee ‘Analysis of samples from — 150°C to desired 7500 high temperature [7 | Mechanical Testing using UTM ‘Approved 1400 | protocol as per ASTM FTIR Spectroscopy ‘Approved protocol based Data file for each spectrum ‘on ASTM Overlay spectra FT Raman Spectroscopy ‘Approved With hard copy of the spectrum & tiff image protocol 3200 7 in CD using InGaAs detector eae With hard copy of the spectrum & tiff image 3300 in CD using Germanium detector Data file for each spectrum Approved 300 Overlay spectra poe 300 Spectrum of the substrate ( glass/quartz) for Bea 300 thin film spectra ental Thermocycler Products [9750 basic rate for 2 hrs and | additional 225/hr [a2 | Micro CT Testing Approved 8700 [a | Supplementary analysis protocol 300/analysis =~ 12 | Vickers’s Micro hardness Testing Approved 1100 protocol as per ASTM FH 3B Approved 300 L DLS. protocol 14 | Zeta Potential a 500 15 | Shore A/Shore D Analysis ‘Approved 150 per sample protocol 16 | Thermal Analysis a | DSC 50°C to 400°C ) in Oxygen/ Nitrogen | ASTM E 1356- 3300 Atmosphere 03 b | Modulated DSC z= 3300 c | DTA (RT to 1400°C) ‘Approved 3300 [ protocol Central TGA (RT to 1400°C) ASTM 1131-03 | Analytical | 3300 17 | GPC/HPLC/EC ie Facility a | Gel Permeation Chromatography: GPC Approved 3300 protocol based on ASTM D 5296 b | HPLC ‘Approved 2100 protocol 18 | FTIR Spectroscopy (ATR/ KBr) Approved 1800 protocol based _—— Data in CD on ASTM. 150 19 | UV-VISIBLE light Spectroscopy "Approved 1700 el protocol 20 | Gas Chromatography ‘Approved 5400 Estimation of Ethylene Oxide Residues- protocol 21 | Solution Viscosity of Biopolymers 300/test(3 | replicate samples) 22 | Fluorescence Microscopy Imaging 600/hr 23 | Luminescent Image Analysis | 200/exposure a [2a | Mechanical testing of tissues (Texture 900/test (6 replicate i] Analysis) a samples) 25 | Micro Raman Spectroscopy 900/sample 26 | Confocal Raman Microscopy 3000/sample 27 | Fluorescence Intensity and Absorbance 150/plate Measurements - Microplate 28 | Fluorescence and Absorbance Scan - 150/plate Microplate 29 | Transmission Electron Microscopy (TEM) Approved | Transmissio | 9300 | Analysis) - Biological protocol | n Electron ‘A. | Transmission Electron Microscopy (TEM) Microscopy | 4590 Analysis) - Inorganic (TEM) 30 | SEM Analysi ~ Approved oe a | Scanning Electron Microscopy (SEM) protocol 2300 Analysis (Without coating) b | Scanning Electron Microscopy Analysis (with 2300 gold coating) c_| Scanning Electron Microscopy Analysis — 3300 Biological samples ic ss Scanning d_ | Scanning Electron Microscopy Analysis (with 3300 i Electron critical point drying & gold coating) : Microscopy |_ | Scanning Electron Microscopy - EDS Analysis (sem) | 4200 ¥_| SEM-EDS Analysis for Biological samples 4950 g | SEM (For more than 3 micrographs toa 300 maximum of 5 - additional charge/ image) h_| SEM-EDS Analysis (For more than 2 image 500 spectra additional charge/image spectra) 31 | Confocal microscopy Approved Division of | 1700 protocol Tissue Culture 32 | Profilometer - line scanning Manufacturer Calibration | 1400 instruction Cell a_| Profilometer- surface scanning 2700 Verified By de rowel Ag SIC, Customer Service Cell Head, BMT Wing

You might also like