0% found this document useful (0 votes)
97 views4 pages

ABB DTM400 Bundle

This document provides information about the ABB DTM400 device type manager bundle, including supported devices, requirements, installation instructions, and version history. The DTM400 bundle contains DTMs for configuring ABB HART, PROFIBUS, FOUNDATION Fieldbus, and MODBUS field devices. Requirements include supported PC hardware, operating systems, and software packages. The version record lists updates to the DTM400 library and changes made in each release, including bug fixes, added or removed device DTMs, and new features.

Uploaded by

Mt. Sasongko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views4 pages

ABB DTM400 Bundle

This document provides information about the ABB DTM400 device type manager bundle, including supported devices, requirements, installation instructions, and version history. The DTM400 bundle contains DTMs for configuring ABB HART, PROFIBUS, FOUNDATION Fieldbus, and MODBUS field devices. Requirements include supported PC hardware, operating systems, and software packages. The version record lists updates to the DTM400 library and changes made in each release, including bug fixes, added or removed device DTMs, and new features.

Uploaded by

Mt. Sasongko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Supplementary Information Driver ABB DTM400 Bundle

3KXD801400R3901 Rev. J General

Content 1 Device - Revision Record - What is new?


1.1 Hardware
1 Device - Revision Record - What is new? ...............1 See the respective device driver Supplement-Info*)
1.1 Hardware..................................................................................... 1
1.2 Software ...................................................................................... 1 1.2 Software
1.3 Firmware ..................................................................................... 1 See the respective device driver Supplement-Info*)
2 DTM - Device Type Manager ....................................1
2.1 Supported devices....................................................................... 1 1.3 Firmware
2.2 DTM bundle Version record - What is new? ............................... 1 See the respective device driver Supplement-Info*)
2.3 Requirements .............................................................................. 2
2.3.1 PC-Hardware, Operating system ............................................... 2
2.3.2 Frame application / compatibility................................................. 2 2 DTM - Device Type Manager
2.3.3 Software package contents ........................................................ 2
2.4 Installation and configuration....................................................... 2 2.1 Supported devices
2.4.1 Installation .................................................................................. 2 “ABB DTM400” is the name of an ABB DTM Bundle for HART,
2.4.2 Uninstall instructions .................................................................. 2 PROFIBUS, FOUNDATION Fieldbus and MODBUS field devices. The
2.5 Update- / Upgrade instructions ................................................... 2 following supplementary information refers to all DTMs / DMAs of this
2.6 Known problems and limitations .................................................. 3 package.
2.7 Getting help / further information................................................. 3 The number and type of the DTMs in this package are shown chapter
2.8 How to get the latest info & software? ......................................... 3 2.3.3.
2.9 Licensing the DTM ...................................................................... 3
2.2 DTM bundle Version record - What is new?
Released Released Released Remarks
bundle Date DTM400
Version Library
*) The individual device driver Supplement Info & Software is available
Version
on the data medium or latest in www.abb.com/fieldbus.:
-- Dec. 2005 2.00.36 New hints in chapter 2.6
latest information [Field device protocol dependent]
Patch 5
latest info (download) [device type dependent]
-- May 2008 2.00.36 - Bug fix
- Driver description
Patch 10 - Updated device DTM’s
- Software [driver type dependent]
- New device DTM’s
02.00.01 Jan 2009 2.00.36 First release of the DTM400
Patch 10 bundle setup
02.01.00 May 2009 2.00.36 Updated device DTM’s
Patch 10 - FSM4000-HART
- Contrac-DPV1
02.01.01 Sep. 2009 2.00.36 New features
Patch 11 - Import functionality
Updated device DTM’s
- MV2600-PA
- TO2600-PA
02.01.02 Oct. 2009 2.00.36 - Setup Bug fix
Patch 11
02.02.00 Nov. 2009 2.00.36 Deleted device DTM’s
Patch 11 (now part of the DTM500 Bun-
dle)
- HI2600 (264xx) HART
- TTX300 HART
- TZIDC HART
02.03.00 Jun. 2010 2.00.36 - Setup Bug fix
Patch 11 - Updated device DTM’s
- SA2600-HART
02.04.00 Jun. 2011 2.00.36 Deleted device DTM’s
Patch 11 (now part of the DTM500 Bun-
dle)
- TTX200 HART
02.05.00 Aug. 2011 2.00.36 - Setup Bug fix
Patch 11 - Updated device DTM’s
- DTM ST2600-HART (261)
Driver ABB DTM400 Bundle
General 3KXD801400R3901 Rev. J

2.3 Requirements for pressure and level transmitters


2.3.1 PC-Hardware, Operating system - DTMHI2600-PA for 2600T(264xx) PNO-ID: 0x052B
- DTMTO2600-PA for 2600T(265xx), 2010Tx, 2020Tx
- Minimum requirement
PNO-ID: 0x04c2
Intel Pentium III Processor 450 MHz or compatible
- DTMMV2600-PA for 2600T(267xx, 269xx), MV2010TC
256 MB RAM memory
PNO-ID: 0x062D
300 MB free hard disk space
1024 x 768 screen resolution for positioners
Windows 2000 SP4 / XP SP2 - DTMTZIDC-PA for TZIDC-110, TZIDC-210 PNO-ID: 0x0639
Internet Explorer 6.0
for temperature transmitters
Adobe Reader latest version
- DTMTFX12-PA for TF12, TF212 PNO-ID: 0x04c4
Member of the "Administrators" group
DTM for MODBUS devices:
The ABB DTMs of the DTM400 Bundle are released for Windows 2000
for pressure and level transmitters
Professional and Windows XP Professional as PC / Notebook installa- 1,2
tion. - DTMMV2600-MODBUS for 2600T(267xx, 269xx), MV2010TC

ABB recommends that a virus scanner is used on all PCs/Notebooks, DMA for FOUNDATION Fieldbus devices:
where Asset Vision and/or DTMs are installed. for pressure and level transmitters
1,2
McAfee VirusScan® Enterprise has been tested and qualified for this - DMAMV2600-H1 for 2600T(267xx, 269xx), MV2010TC
purpose. 1
) Available only on the „DTM400 & DSV401 (SMART VISION)“ CD-
2.3.2 Frame application / compatibility ROM [Documentation-ID: 08/FB-01 XA].
2
) Available only in www.abb.com/fieldbus:
See the respective device driver Supplement-Info*) latest information [Field device protocol dependent]
latest info (download) [device type dependent]
2.3.3 Software package contents - Software [driver type]
DTM for HART devices:
for electrical actuators
- DTMCONTRAC-HART for CONTRAC family 2.4 Installation and configuration
for flow transmitter 2.4.1 Installation
- DTMFAM5400-HART for FAM5400(AM54) – Make sure that the minimum hardware requirements are met.
- DTMFCM2000-HART for FCM2000(CoriolisMaster) – Start Windows (login with administrator rights!).
- DTMFMT500-HART for FMT500-IG(Sensyflow iG) – Cancel all running programs.
- DTMFSM4000-HART for FSM4000
– Insert data medium or unpack the DTM zip file available as download
- DTMFVS4000-HART for FV4000, FS4000(TRIO WIRL)
from www.abb.com/Instrumentation.
- DTMFXE4000-HART for FXE4000(COPA-XE/MAG-XE)
– Start the installation Wizard as follows:
for pressure and level transmitters Data medium <drive>:\Setup.exe
- DTM600T-HART for 600T(61xx, 62xx) or
- DTMST2600-HART for 2600T(261xx) DTM zip file \Revxx.yy.zz_yyyy.mm\Setup.exe
- DTMTO2600-HART for 2600T(265xx), 2010Tx, 2020Tx – Follow the instructions.
- DTMMV2600-HART for 2600T(267xx, 269xx), MV2010TC
- DTMSA2600-HART for 2600T(268xx) 2.4.2 Uninstall instructions
- DTM364-HART for 2600T(364xx)
– For individual DTM un-installation see the respective device driver
for temperature transmitters Supplement-Info*)
- DTMTHX02-HART for TH02, TH102, TH202 – For Bundle un-installing start in the operating system:
Start -> Settings -> Control Panel -> Software -> Install/Uninstall
DTM for PROFIBUS devices: 1. First un-install ALL DTMs/DMAs.
for electrical actuators (but NOT “DTM Library Patch“, "ABB DTM LIBRARY",
- DTMCONTRAC-DPV1 for CONTRAC DP-V1 family “ABB DTM500” and “ABB DTM Contrac-LCI…”)
PNO-ID: 0x09EC That are the DTMs starting with:
for analyzers 600T, ABB Engineer IT DTM*, Engineer IT DTM*,
- DTMTB82EC-PA for TB82EC23xx PNO-ID: 0x5102 ABB Engineer IT DMA*, ABB DTM* and DTM*.
- DTMTB82TC-PA for TB82TC23xx PNO-ID: 0x5104 2. Finally un-install first “DTM Library Patch“ and then
- DTMTB82TE-PA for TB82TE23xx PNO-ID: 0x5103 "ABB DTM LIBRARY".
- DTMTB82PH-PA for TB82PH23xx PNO-ID: 0x5101 3. Reboot your computer!

for flowmeters 2.5 Update- / Upgrade instructions


- DTMFCM2000-PA for FCM2000(CoriolisMaster)
See the respective device driver Supplement-Info*)
PNO-ID: 0x0849
- DTMFMT500-DP for FMT500-IG(Sensyflow iG)
PNO-ID: 0x05CA
- DTMFSM4000-PA for FSM4000 PNO-ID: 0x078C
- DTMFVS4000-PA for FV4000, FS4000(TRIO WIRL)
PNO-ID: 0x05DC
- DTMFXE4000-PA for FXE4000(COPA-XE/MAG-XE)
PNO-ID: 0x0691

2
Driver ABB DTM400 Bundle
General 3KXD801400R3901 Rev. J

2.6 Known problems and limitations 2.8 How to get the latest info & software?
In addition to the specific hints in the respective field device – The latest DTM400 Bundle Supplement Info is available on
3K*R3901_Supplement-Info-Driver*.pdf the general hints are attached. www.abb.com/fieldbus:
Enter here in the search field following No. “3KXD801400R3901”.
Valid for FDT frame applications only:
– TAG cannot be set via a DTM. The latest DTM400 Bundle software is available on
In DSV401 Rx (SMART VISION) this limit does not apply. www.abb.com/fieldbus:
Enter here in the search field following No. “3KXD800400S0030”.
– DTM cannot switch to Offline mode if working with Online Application.
Device has to be disconnected first and then the DTM can be – For the single device driver see the respective Supplement Info &
switched to Offline mode only. Software*)
In DSV401 Rx (SMART VISION) this limit does not apply.
– It could happen that the list of available functions for a DTM in the 2.9 Licensing the DTM
frame application does not get updated. If that happens, click on "New – The ABB DTM400 Bundle is usable without any license in any
project" in the frame and when prompted to save click on "Cancel". frame application.
The DTM menu with all functions in the frame will be available again. – After the installation the ABB DTM400 Bundle runs 90-days in
In DSV401 Rx (SMART VISION) this limit does not apply. demo mode (full functionality) and needs to be purchased within
– The individual ABB DTM400 Bundle DTMs must be closed before the this period, when the storage of data being
FDT frame application. requested.
In DSV401 Rx (SMART VISION) this limit does not apply. – By purchasing the DSV401 (SMART VISION) single PC license the
– The individual ABB DTM400 Bundle DTMs must be closed before the ABB DTM400 Bundle is also operable without restriction and does not
ABB DTM400 DTM could be disconnected (Offline) in the project tree have to be ordered separately!
of the FDT frame application.
In DSV401 Rx (SMART VISION) this limit does not apply.
– It is only possible to use „Save as...“ and „Open“ (parameter data
Export / Import) in the individual ABB DTM400 Bundle DTMs via an
FDT frame application.
Workaround:
1. Start “Export” of Parameter data
+ Open DTM400 DTM via the Frame Tool
+ Change Parameter inside the DTM400 DTM
by upload from the device or manual input
+ 1. Click “Save” in the Menu / Icon bar of the DTM400 DTMs
2. Click “Save” afterwards also in the Menu / Icon bar
of the Frame Tool.
+ Click on the DTM400 DTM node in the Frame Tool project tree.
Right mouse click ->Additional functions ->Export
Stored the parameter data on your medium.

2. Start “Import” of Parameter data


+ Open DTM400 DTM via the Frame Tool
+ Click on the DTM400 DTM node in the Frame Tool project tree.
Right mouse click ->Additional functions ->Import
! No other way starts the “Import” functionality !
+ Download of the imported Parameter into a device
is now possible
+ If you want to store the imported Parameter afterwards
also in the Instance Data (Project) go ahead as following:
- Click “Save” also in the Menu / Icon bar of the Frame Tool.
In DSV401 Rx (SMART VISION) this limit does not apply.
– PROFIBUS devices with address 126 are not possible to configure
with the driver of the DTM400 Bundle.
Workaround:
+ Change the PROFIBUS address to a not in use address < 126.
+ Start the device configuration again.
– Individual DTMs available with the ABB DTM400 bundle might not
fully support the ABB Asset Vision Basic (DAT200) Point-to-Point
Wizard. Error messages might come up (e.g. "Failed to open ActiveX
Control of ...") or the DTM's Parameter window is not opened at the
end of the wizard execution.
Please preferably use the ABB Asset Vision Basic (DAT200) Expert
Mode with DTM400 DTMs.

2.7 Getting help / further information


See the respective device driver Supplement-Info*)

3
Driver ABB DTM400 Bundle
General 3KXD801400R3901 Rev. J

ABB provides expert and comprehensive consulting ABB is continually improving its products. As a
services in more than 100 countries worldwide. result, technical information in this document is
subject to change.
http://www.abb.com/instrumentation
Printed in the Fed. Rep. of Germany (08.2011)

© ABB 2011
3KXD801400R3901 Rev. J

Germany USA Italy UK P.R. China

ABB Automation Products GmbH ABB Inc. ABB S.p.A. ABB Limited ABB Engineering (Shanghai) Ltd.
Borsigstr. 2 125 E. County Line Road Via Statale 113 Oldends Lane 32 Industrial Area
63755 Alzenau Warminster, PA 22016 Lenno (CO) Stonehouse Kangqiao Town, Nanhui District
18974-4995 Gloucestershire GL10 3TA Shanghai, 201319

Tel: +49 (0)551 905-534 Tel: +1 (0)215 674 6000 Tel: +39 0344 58111 Tel: +44 (0)1453 826 661 Tel: +86 (0) 21 6105 6666
Fax: +49 (0)551 905-555 Fax: +1 (0)215 674 7183 Fax: +39 0344 56278 Fax: +44 (0)1453 829 671 Fax: +86 (0) 21 6105 6677
[email protected] [email protected] [email protected] [email protected] [email protected]

You might also like