BISULFITE SOLUTIONS FOR SANITISING, DECHLORINATION AND RO MEMBRANES

MATERIAL & FUNCTION

SODIUM METABISULFITE SOLUTIONS (SMBS 40%, 37%, 20%, 12.5% and 5%) are a source of
sulfur dioxide which has strong antimicrobial properties. It is also a strong reducing agent used for
removing chlorine and chloramines from water. It releases sulfur dioxide a pungent, unpleasant
smelling gas that can also cause breathing difficulties in some people. It is used as a sterilizer,
antioxidant and preservative.

An SMBS solution is made by dissolving solid SODIUM METABISULFITE into water and has a pH of
4.6 at 1.0 % (by weight) solution strength. The SMBS solution is not stable to air and reacts with
oxygen as well as chlorine, therefore it is recommended that batches of less than 2 % by weight be
used within 3 to 7 days and batch solutions less than 10 % be used within 7 to 14 days. Theoretically,
0.70 ppm of SODIUM METABISULFITE) will stoichiometrically neutralize 1.0 ppm of chlorine.
TECHNICAL BULLETIN

19 Motivation Dve Wangara, WA, 6065 AUSTRALIA


T +61 8 9302 4000 | FREE 1800 999 196 | F +61 8 9302 5000

· Na2S2O5 (SODIUM METABISULFITE) + H2O → 2 NaHSO3 (sodium bisulfite)

· NaHSO3 + HOCl → NaHSO4 (sodium bisulfate) + HCl (hydrochloric acid)

· NaHSO3 + Cl2 + H2O → NaHSO4 + 2 HCl

APPLICATIONS

1. Dechlorination:

Free Available Chlorine in RO and NF feed waters need to be reduced to less than 0.05 ppm (as Cl2)
for compliance of Composite Polyamide [CPA] membrane warranties. The two most common
pretreatment methods for reducing chlorine levels are by absorption onto activated granular carbon
filter media or by the use of a chemical reducing agent such as sodium bisulfite.

Pressurized carbon filters are typically used on small systems (50 to 100 gpm or less) due to capital
cost considerations. The advantages of a carbon filter are their ability to remove organics from the
feedwater that could foul the RO membrane and they are more reliable in treating all the feed water
than a chemical feed system. The disadvantage is that carbon filters are notorious for breeding
bacteria that can result in a biological fouling of the RO. Carbon filters have been known to see a
doubling of viable bacteria counts in 24 hours

SODIUM METABISULFITE [SMBS] is the typical chlorine reducing agent of choice for larger RO
systems.

A dosing rate of 2.0 to 3.0 ppm SMBS per 1.0 ppm chlorine so as to include an industrial safety factor
for brackish water RO systems with at least 20 seconds of reaction time. Proper in-line mixing is
required which preferably includes a static mixer.

The advantages of SMBS dechlorination are that it is less capital intensive than carbon filters for large
systems, the reaction by-products are readily removed by the RO, and residual SMBS is readily
removed by the membrane.

The disadvantages of SMBS are the small volume of chemical required, the increased risk in chlorine
making it to the membranes if sufficient monitoring and controls are not designed into the
dechlorination system. In a few cases where Sulfur Reducing Bacteria [SBRs] are present in the feed
supply the bisulfite functions as a nutrient and enhances their growth. SBRs are usually found in
anaerobic (low oxygen content) shallow ground water. Frequently hydrogen sulfide (H2S) is also
TECHNICAL BULLETIN

19 Motivation Dve Wangara, WA, 6065 AUSTRALIA


T +61 8 9302 4000 | FREE 1800 999 196 | F +61 8 9302 5000

present as a by-product of the SBR metabolic process.

Monitoring for dechlorination can be performed by the use of an Available Free Chlorine monitor,
monitoring for a residual bisulfite concentration, or by an ORP monitor. The preferred method is to
monitor for a residual bisulfite concentration, as this assures one that sufficient bisulfite exists to have
neutralized all chlorine. Most commercial chlorine monitors measure with accuracy down to only 0.1
ppm, which is the upper limit for CPA membranes. The use of ORP monitors to indirectly measure
residual bisulfite levels by the oxidation/reduction (Redox) level of the feedwater have proven not to
be reliable due to hard to predict variability of the baseline millivolt readings.

ANTIMICROBIAL AGENT

Microbial growth can occur on either side or within the membrane. To be effective in killing microbes
in the units when only one side of the membrane is available to treatment the antimicrobial
composition must be able to pass through the membrane. Most common organic antimicrobial
compounds having molecular weight greater than about 150 cannot successfully prevent or destroy
microbial growth within membranes and on both surfaces since they cannot pass through the
membrane.

SMBS solution should be dosed at 0.1 % v/v to 0.3% v/v at ambient temperature and left in contact
with the Membrane for at least 30 minutes. Ensure that manufacturer’s recommendations with respect
to temperature, pH, time and concentration are met.

Theoretically, SMBS solution contains 40% SODIUM METABISULFITE. However, It does react with
oxygen in the air and will lose some activity as Sulfur dioxide gas. Strength will also decrease on
exposure to sunlight and heat. At full strength, Mem Clean MBS contains the equivalent of 24 % SO2

CAUTION

Avoid contact with skin and eyes and avoid breathing vapour or spray mist. SMBS solution is an
aqueous solution producing sulfur dioxide. A Material Safety Data Sheet (MSDS) is available on
request.

Classification: Xn Harmful. R22 Harmful if swallowed. R31 Contact with acids liberates toxic gas. R41
Risk of serious damage to eyes.

PACKAGING
TECHNICAL BULLETIN

19 Motivation Dve Wangara, WA, 6065 AUSTRALIA


T +61 8 9302 4000 | FREE 1800 999 196 | F +61 8 9302 5000

15, 20, 200 Litre containers

IMPORTANT NOTICE TO CUSTOMER

Since the use of this product is beyond the control of either seller or manufacturer, their only obligation
shall be to replace any quantity of product which is proven defective. They cannot assume any risk or
liability in excess of the purchase price of the product itself, which does not include labour or any
consequential damages resulting from the use of this product. Determining the suitability of this product
for any intended use shall be solely the responsibility of the user. ALWAYS TEST FIRST