VRF SLB010 en - 100714

Download as pdf or txt
Download as pdf or txt
You are on page 1of 40

TVR Select™

Certified Comfort
TVR™ Select systems...meeting all standards 3
Why TVR™ Select 4
Simultaneous Heating and Cooling 5
System Features 8
Outdoor Units 12
Indoor Units 18
Intelligent Management Control System 32
Service Software 39
Other Accessories 39
TVR™ Select systems...meeting all standards
A flexible and certified solution for each project TVR Select is designed to maximize the comfort of the
The new TVR Select system under the TRANE brand user by matching the cooling or heating load required in
represents a technological leap. each zone with no overheating or under cooling, keeping
the ambient temperature within 0.9 F from the established
The new TVR Select includes features like simultaneous setpoint.
heating and cooling using the heat recovery series and at the
same time reducing energy consumption while maintaining Indoor air quality
optimal climate conditions within the building. While cooling or heating, the TVR Select system also
dehumidifies the indoor air and independently filters the air in
The new TVR Select achieves higher levels of energy each zone with no possibility of cross contamination between
efficiency in both cooling (EER) and heating (COP) independent zones.
complying with the ANSI/AHRI Standard 1230-2010
and with the AHRI Standard 210/240-2008 for Mini TVR
Select units.This is accomplished through the use of an
optimized fan design with a DC fan motor, an improved
high performance heat exchanger, Brushless Reluctance DC
inverter scroll compressors and intelligent defrost capability.

TVR Select can be applied as the main HVAC system in a


building or as a supplemental system that coordinates with
an existing HVAC installation to meet different application
requirements.

The TVR Select is ideal for buildings that have different


requirements for future tenants, for buildings requiring
tenant by tenant installation, operation and billing. The
compact size of the indoor units, the small footprint and
modularity of outdoor units and the use of small refrigerant TVR Select’s individual independent control per zone
pipes to transport energy between outdoor and indoor units
make this product the ideal solution for existing buildings. All functions necessary for filtration, cooling and heating,
ventilation and dehumidification are fully integrated within
Individual control
the TVR Select system.
The use of individual LCD zone controllers, allows users to
meet their individual comfort needs as the TVR Select system The indoor air quality can be improved when pretreated
will control the refrigerant flow to each individual zone in outside air is introduced into the building either through
order to meet the cooling or heating requirements. direct connection to the indoor units (4-way cassette units)
or through our 100% fresh air concealed units.
TVR Select controls are factory integrated, and when
combined with available remote temperature sensors, The TVR Select system can handle the integration with external
programmable controllers, centralized controller or integrated fresh air through different solutions.
into a Building Management System (BMS) you will
ensure the most efficient and reliable operation of an air
conditioning system.

3 VRF-SLB010-EN
Why TVR™ Select ?

Flexible Design
The TVR Select System can be customized to the highest
degree. The ability to use heat pump or heat recovery
modular outdoor units and connect them together in series,
offers the greatest design flexibility possible.

A total of 13 different outdoor unit combinations are


DC INVERTER
available that can be matched with a total of 59 different
indoor units to meet any type of requirement. The largest
345 MBH modules allow the connection of up to 59 indoor
units thus delivering comfort as far as 574 ft. away from the
outdoor units.

The optional high static pressure outdoor fan motor allows


Energy Efficient System floor to floor installation of the outdoor units when this could
The TVR Select system’s automatic power consumption be the optimal solution for a particular application.
adjustment matches the cooling load perfectly to the
The TVR Select system allows customization towards the
changing needs of all the individual zones thus realizing
future where zones can be easily added, replaced or removed
energy savings. The capacity is controlled intelligently and
depending on the changing needs of the end user.
distributed evenly over the different zones without wasting
energy. Energy Management
The optional centralized control system of the TVR Select
Energy Efficiency (EER) increases at partial load when fewer
system already has all the power management data or
indoor units require cooling/heating thus reducing the total
information points of each individual zone. Adding the
power consumption. A TVR Select system does not run at
power measurement software to the system allows the user
full speed all the time and during a typical daily operation a
to calculate the individual power consumption per zone,
TVR Select system will work for a majority of its time in the
per floor or per building. The control software will require
unloading zone with higher energy efficiency. During partial
a digital ammeter per outdoor unit and the Web Gateway
load the inverter compressor runs at reduced speed matching
centralized controller.
the required building load.

4 VRF-SLB010-EN
Simultaneous Heating and Cooling
Heat Recovery
The TVR™ Select heat recovery systems provide for
simultaneous cooling and heating while achieving a
better energy efficiency.

During this operation the refrigerant being


condensed by the indoor units in the heating mode
is used to provide part of the cooling required
by the indoor units that are in a cooling mode
at the same time; under this condition energy
consumption can be reduced significantly.

Example of TVR Select


Heat Recovery system

TVR Select MS Boxes


The MS (Mode Switch) boxes allow for simultaneous cooling and heating for up to 6 groups of 4 indoor units each,
for a total of 24 units connected to only 1 MS box. This great design makes the TVR Select heat recovery system
particularly flexible with several combination options available. This flexibility translates to: reduced first equipment,
reduced installation costs and ease of installation. Less piping and fewer MS boxes are required to perform the same job
as compared to an individual MS box arrangement, all of which provides for much easier installation in the field.
Cooling Cooling Heating Heating
14.0kW 14.0kW 14.0kW 14.0kW

TVR Select Heat Pump system


TVR Select Heat Recovery system

Cooling Heating Heating Heating


14.0kW 14.0kW 14.0kW 14.0kW

Cooling Cooling Heating Heating


14.0kW 14.0kW 14.0kW 14.0kW

Cooling Heating Heating Heating


14.0kW 14.0kW 14.0kW 14.0kW
5 VRF-SLB010-EN
DC Inverter Advantage
Energy Saving
The introduction of a high efficiency DC inverter scroll compressor driven by the most advanced control technology is designed
to provide more precise operation and improved system efficiency.

The compressor speed is adapted to match the fluctuating cooling/heating load of the complete building while ensuring the
appropriate individual variable supply of cooling/heating for each independent zone.

The control system uses PWM (Pulse Width Modulation) control that optimizes the efficiency once the setpoint temperature is
reached, avoiding temperature fluctuation and thus reducing power consumption.

Accurate temperature control leading to Ideal comfort


Graph 1: Traditional air conditioners maintain the temperature by continually starting and stopping the compressor after
reaching the temperature setpoints.

Traditional compressors require minimum time between starts and stops which leads to a wide fluctuation of indoor
temperature.

Graph 2: With advanced digital variable refrigerant flow control technology, TVR™ Select system can accurately control the room
temperature within a narrow temperature band thus avoiding wasting energy and creating the most comfortable environment.
The setpoint will be stable at +/- 0.9° F.

Graph 1 Graph 2

DC INVERTER

DC INVERTER

6 VRF-SLB010-EN
Longevity TVR™ Select Energy Efficiency
DC Inverter scroll compressors do not start and stop all

IEER Non-Ducted
the time and thus will have a longer lifetime compared to

4TVH0072
standard compressors used in traditional systems. 22.6

22.8
The electronic control can adjust/optimize the compressor’s
operating conditions under extreme weather by changing

4TVH0096
the compressor speed during freezing winter or high summer 23

outdoor temperatures. This greatly extends the lifetime

IEER Ducted
23.7
operation of the compressor. The TVR Select system’s auto
diagnostic continually monitors the complete system and

4TVH0115
21.9
allows fast troubleshooting with the display of alarm codes
on controllers or through the BMS interfaces. 22.8

19 19.5 20 20.5 21 21.5 22 22.5 23 23.5 24

DC Inverter scroll compressor technology advantages


• New structure-enhanced mid-frequency performance
• Especially designed scroll profile for R410A
• Advanced permanent magnet DC motor improves the low frequency band performance

The high efficiency R-410A high pressure dome scroll compressor has a revolutionary
asynchronous motor design using integrated permanent Neodymium magnets creating a magnetic
field with extra reluctance torque which greatly increases the efficiencies in low and medium speeds.

Due to the magnetic field, the motor will place itself in the perfect position that will allow the
compressor a soft start with the lowest amperage draw.

Environment - R410A refrigerant


The TVR™ Select system operates with the highly efficient R410A refrigerant with zero ozone layer
depleting potential. R410A provides increased heat transfer and system performance; as a result
it reduces the required amount of refrigerant, the size of required piping, and hence of general
installation costs.

7 VRF-SLB010-EN
System Features
The TVR™ Select product portfolio offers a complete range of outdoor units to meet the right needs of different applications.
There are three different types of outdoor units that can be matched to our new TVR Select indoor units:
• Mini TVR Select: Nominal capacity range from 36 to 48 MBH*
• Modular TVR Select Heat Pump: Nominal capacity range from 72 to 345 MBH*
• Modular TVR Select Heat Recovery: Nominal capacity range from 72 to 345 MBH*
* see outdoor unit specs for more details

Self-Addressing of indoor units


• The outdoor unit will automatically distribute the
Automatically addresses to indoor units without any manual settings
™ Identify (this function applies to vertical discharge heat pump
DC INVERTER
units only).
• Wireless controller TCONTRM05B and new TCONTKJR29B
can modify every indoor units address.
• Max. 59 indoor units can be connected to one system and
identified automatically.

Outdoor unit static pressure


Optional adjustable high static outdoor fan motor is available for different applications. All units can
be customized to reach 0.24” WG of external static pressure. The standard static pressure is
0-0.08” WG.

DC fan motor
The DC fan motor offers substantial improvements in operating efficiency compared to conventional
AC motors, especially during low speed rotation.

To achieve the minimum energy consumption and best performance, it controls the speed of DC fan
according to the running load and system pressure.

This new DC fan motor also reduces noise level when working under certain
part-load conditions

8 VRF-SLB010-EN
Auto-rotation of outdoor units
When more than one outdoor unit is installed within
a modular system, the TVR™ Select system rotates
the master unit automatically to ensure a longer life
cycle of the complete system. This rotation takes
place when the unit re-starts operation after it has
reached a setpoint, after the oil return process, and
after the defrost process (in heating operation).

All inverter compressors


The TVR Select outdoor units utilize all inverter compressors which adds more flexibility and reliability to the system as compared
to the combination of fixed and inverter compressor technology. The ability to perform at higher compressor speeds allows the
system to reach longer piping distances (up to 574 ft.) and more comfort zones (up to 3280 ft. of total piping length).

Priority Mode Selection High Performance Heat Exchanger


In order to reduce the potential for mode conflict and to The new TVR Select units have a high performance heat
exchanger that allows better air flow and longer time of
satisfy priority needs, several types of mode selection are
operation between defrost cycles.
available.

Heating Priority
(default)

Cooling Priority Cooling Only


Fan blade with special profile
A blade with sharp edge and reduced curve increases the
airflow rate and lowers vibration and airflow resistance.

First unit ON Heating Mode

9 VRF-SLB010-EN
Flexibility & Reliability of TVR™ Select System
Piping Length Flexibilities
The unique concept of a pre-engineered system that arrives A
on the jobsite with a predefined piping layout per system
and the necessary piping kits allows for fast and correct
installation of the system.

The actual piping length from the condensing unit to the


indoor unit furthest away is 574 ft. (656 ft. equivalent) up to
a total piping length of 3280 ft.
B
The height difference can be 230 ft. equivalent for outdoor D
units being installed on the roof and 360 ft. lift for outdoor
units installed below or at ground level.

Modular Design
Through the compact modular design the TVR Select
outdoor units can be installed in rows and manifolded in
series together to maximum 345MBH, with 59 indoor units C
connected, providing a clean accessible installation. The
345MBH outdoor unit is however capable to control down
to a 6.9MBH capacity with only one inverter compressor
running.

The load demand for the all inverter compressor units, is


Maximum Actual piping length (A+B+C) 574ft.
better matched through a smooth linear operation that allows
Maximum height between indoor units (D) 98ft.
them to perform with maximum precision. The establishment
230ft./
of an operating frequency range between 60-140Hz, Maximum height between indoor units and outdoor units (B)
360ft.*
guarantees the highest efficiency attainable. The compact Total Actual pipe length 3280ft.
shape allows transport by elevator. * when outdoor unit is below indoor units

Back Up function
When a module fails, whether it is a slave unit or a master
unit, the other modules can continue to work together as one
system provided the gas/liquid valves of the broken down
unit are closed.

As the load increases the different condensing modules will


work as a master slave system optimizing the performance
and energy efficiency.

10 VRF-SLB010-EN
Operation Range Indoor comfort level
• The HP systems can provide either cooling or heating, • The integration of DC inverter technology used in
while the HR systems can provide cooling and heating the condensing unit results in an industry leading low noise
simultaneously. level, i.e., 57 dB(A) at 3.3 ft. for a 72MBH outdoor unit.
• The TVR™ Select mini condensing units have a standard • The noise level of the indoor units is low due to the
low ambient operation kit. This means that the intelligent especially designed fans and heat exchanger designs.
controls on the DC inverter compressor allow for a stable
• The variety of ducted indoor units allow for flexible design
indoor temperature with continuous operation in heating
to meet any sound requirements per zone.
down to -4°F for TVR Select and 5°F for TVR Select mini.

[°F]
TVR Select HP TVR Select HR TVR Select Mini
120
118°F 118°F 118°F
110

100

90

80
81°F

70 75°F 75°F 75°F

60

50

40

30
23°F 23°F 23°F

20

10 5°F 5°F

0 -4°F -4°F

-10

DC INVERTER

23dB (A)
20 dB (A) 30 dB (A) 40 dB (A) 50 dB (A)

Speak in a low voice Quiet language Quiet reading room Quiet office
at 1/5m away laboratory
Noise decibel

* applicable for low air volume operation of 4TVB0007 units.

11 VRF-SLB010-EN
Outdoor Units
TVR™ Select Mini - Residential Comfort
A very compact condensing unit that allows the TVR Select indoor unit range to be connected to a
single outdoor unit.

Features Low Noise


• 2 power levels 36,000 Btu/h and • Very low noise level on the outdoor unit,
47,500 Btu/h 56 dB(A) at 3.28 ft. from the unit
• High efficiency heat pump unit with R410A • Low starting current thanks to the DC inverter
technology
• DC inverter fan motor
• AHRI / ETL certified
Flexibility
• Easy to install, fits inside an elevator, no need
Compact for a crane 4TVH0036C1000AA
• Maximum economy of space, one 4TVH0048C1000AA
• Long piping length for spot cooling or
47,500 Btu/h outdoor unit controls up to
heating, 230 ft. equivalent piping and 98
maximum 7 indoor units
ft. height difference when OD unit is placed
• Can be installed close to a wall above

12 VRF-SLB010-EN
Mini TVR Select ™ Outdoor Units
Model Numbers 4TVH0036C1000AA 4TVH0048C1000AA
Power Supply V/Ph/Hz 208-230/60/1 208-230/60/1
Capacity Btu/h 36,000 47,500
Power Input kW 3.5 5.2
Capacity Range(45% - 110%) Mbh 16.2-39.6 21.4-52.3
Cooling
Efficiency - Ducted Unducted Ducted Unducted
EER - 9.7 9.4 8.3 8.8
IEER - 13.7 14.3 13.45 13.7
Capacity Btu/h 40,000 52,500
Power Input kW 3.7 5
Capacity Range(45% - 110%) Mbh 18-44 23.7-57.8
Heating Efficiency - Ducted Unducted Ducted Unducted
COP @ 47°F - 2.84 2.94 2.7 2.8
COP @ 17°F - 2
HSPF - 8.1 8.4 8.2 8.8
Cooling operation range °F 5~118.4
Heating operation range °F 5~80.6
Airflow Rate CFM 3,500
Sound Pressure dBA 58
Fin Type Hydrophilic aluminum
Dimensions (WxHxD) inches 35-7/14 x 52-1/4 x 12-5/8
Net Weight lbs. 209
Refrigerant - R410a
Refrigerant Charge lbs. 7.3 8.6
Refrigerant Oil fl. Oz 29.4
Liquid Side Ø inch 3/8
Gas Side Ø inch 5/8
Max. Equivalent Pipe Length ft. 230
Max. Height difference between IUs ft. 26
Refrigerant Piping
Max. Height difference for OU above
ft. 98
IU
Max. Height difference for OU below
ft. 66
IU
Max. Amount of IUs connected to OU - 5 7
* Rated per AHRI 210/240-2008 Standard conditions
* Nominal cooling capacities are based on the following conditions: indoor air temperature: 80.6°F DB, 66.2ºF WB, outdoor temperature: 95ºF DB, 75.2ºF WB, DB, equivalent ref. piping: 24.6 ft. (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 68°F DB, 59ºF WB, outdoor temperature: 44.6ºF DB, 42.8ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber and 4.26 ft above the floor.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

13 VRF-SLB010-EN
TVR™ Select Modular Heat Pump Outdoor Units
Condensing units - 60 Hz
• Choice of 2 ~ power supplies: • Continuous cooling up to 23°F and heating
60Hz 460V up to -4°F
60 Hz 220V
• No mechanical rooms needed, fits in elevator
• 3 different modules can work individually
• AHRI / ETL certified
or in a master-slave configuration up to
3 outdoor units
• Any outdoor unit module in a group can be Comfort
the designated master or slave • Auto restart function no need for re-programming

• All TVR Select outdoor units have the same • Low noise design
4TVH0072-115
height and depth allowing for row installation • Back up function
• Improved Linear Capacity Control with all
inverter compressors Service
• Easy maintenance with the self diagnostic
function and test switch
• Flexible start up procedure and automated
piping /wiring checks
Sound Pressure at 3.28 ft.
dB (A) • Self-addressing of indoor units
64.5
64.5 • Optional service software
64
63.5 63.5
63.5
63

62.5
62
61.5

61

60.5

60

59.5

59
4TVH0072 4TVH0096 4TVH0115

Table of Outdoor Unit Connections


Nominal Tons 6 8 10 12 14 16 18 20 22 24 26 28 30
MBH 72 96 115 144 168 192 211 230 264 283 307 326 345
72 X XX X X X
96 X X XX X XX X XX X
115 X X XX X X XX XXX
Max No. Indoor 13 16 20 26 29 33 36 39 46 50 53 56 59

14 VRF-SLB010-EN
TVR™ Select Modular Heat Pump Outdoor Units
<6> 4TVH0072C6000AA 4TVH0096C6000AA 4TVH0115C6000AA
Model Numbers
<4> 4TVH0072C4000AA 4TVH0096C4000AA 4TVH0115C4000AA
V/Ph/Hz 208-230/60/3
Power Supply
V/Ph/Hz 460/60/3
Capacity Btu/h 69,000 92,000 114,000
Power Input kW 5.27 7.48 10
Capacity Range(50% - 130%) Mbh 34.5-89.7 47.5-119.6 57-148.2
Cooling
Efficiency - Ducted Unducted Ducted Unducted Ducted Unducted
EER - 12.8 14.1 12.4 13.2 11.4 12.2
IEER - 22.6 22.8 23 23.7 21.9 22.8
Capacity Btu/h 77,000 103,000 120,000
Power Input kW 5.64 8.27 10.2
Capacity Range(50% - 130%) Mbh 38.5-100.1 51.5-154.5 60-156
Heating
Efficiency - Ducted Unducted Ducted Unducted Ducted Unducted
COP @ 47°F - 3.85 4.29 3.63 3.82 3.45 3.66
COP @ 17°F - 2.41 2.8 2.3 2.52 2.3 2.38
Cooling operation range °F 23~118.4
Heating operation range °F -4~75.2
Airflow Rate CFM 7,130
Sound Pressure dBA 63.5 63.5 64.5
Fin Type Hydrophilic aluminium
Dimensions (WxHxD) inches 49-1/4×63-1/8×30-1/8
Net Weight lbs. 635
Refrigerant - R410a
Refrigerant Charge lbs. 28.7
Refrigerant Oil fl. Oz 169.1
Liquid Side Ø inch 3/8 1/2 1/2
Gas Side Ø inch 7/8 7/8 1-1/8
Refrigerant Max. Equivalent Pipe Length ft. 656
Piping Max. Height difference between IUs ft. 98
Max. Height difference for OU above IU ft. 230
Max. Height difference for OU below IU ft. 360
Max. Amount of IUs connected to OU - 13 16 20
<4> = 460 V, 3 ph, 60Hz
<6> = 220 V, 3 Ph, 60 Hz

* Rated per AHRI-1230 Standard conditions
* Nominal cooling capacities are based on the following conditions: indoor air temperature: 80.6°F DB, 66.2ºF WB, outdoor temperature: 95ºF DB, 75.2ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 68°F DB, 59ºF WB, outdoor temperature: 44.6ºF DB, 42.8ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber and 4.26 ft. above the floor.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

Optional Accessories
• TVR™ Select Outdoor unit centralized
controller TCONTCCM02A
• Digital ammeter

30 Tons unit

15 VRF-SLB010-EN
TVR™ Select Modular Heat Recovery Outdoor Units
Condensing units - 60 Hz
• Choice of 2 ~ power supplies: Comfort
60Hz 460V • Auto restart function no need for re-programming
60 Hz 220V
• Low noise design
• 3 different modules can work individually or
• Back up function
in a master-slave configuration up to 3
outdoor units
Service
• Any outdoor unit module in a group can be
• Easy maintenance with the self diagnostic
the designated master or slave
function and test switch
• All TVR Select Heat Recovery outdoor units
• Flexible start up procedure and automated
have the same height and depth allowing for 4TVR0072-115
piping / wiring checks
row installation
• Self-addressing of indoor units
• Improved Linear Capacity Control with all
inverter compressors • Optional service software
• No mechanical rooms needed, fits in elevator
• AHRI / ETL certified

Sound Pressure at 3.28 ft.


dB (A)
58.5
58
58
57.5
57 57
57

56.5

56

55.5
4TVH0072 4TVH0096 4TVH0115

Table of Outdoor Unit Connections


Nominal Tons 6 8 10 12 14 16 18 20 22 24 26 28 30
MBH 72 96 115 144 168 192 211 230 264 283 307 326 345
72 X XX X X X
96 X X XX X XX X XX X
115 X X XX X X XX XXX
Max No. Indoor 13 16 20 26 29 33 36 39 46 50 53 56 59

16 VRF-SLB010-EN
TVR™ Select Modular Heat Recovery Outdoor Units
<6> 4TVR0072C6000AA 4TVR0096C6000AA 4TVR0115C6000AA
Model Numbers
<4> 4TVR0072C4000AA 4TVR0096C4000AA 4TVR0115C4000AA
V/Ph/Hz 208-230/60/3
Power Supply
V/Ph/Hz 460/60/3
Capacity Btu/h 69,000 92,000 114,000
Power Input kW 5.1 7.2 10
Capacity Range(50% - 130%) Mbh 34.5-89.7 47.5-119.6 57-148.2
Cooling
Efficiency - Ducted Unducted Ducted Unducted Ducted Unducted
EER - 12.8 14.1 12.4 13.2 11.4 12.2
IEER - 22.6 22.8 23 23.7 21.9 22.8
Capacity Btu/h 77,000 103,000 120,000
Power Input kW 5.64 8.27 10.2
Capacity Range(50% - 130%) Mbh 38.5-100.1 51.5-154.5 60-156
Heating
Efficiency - Ducted Unducted Ducted Unducted Ducted Unducted
COP @ 47°F - 3.85 4.29 3.63 3.82 3.45 3.66
COP @ 17°F - 2.41 2.8 2.3 2.52 2.3 2.38
SCHE 27.2 28 26.9 27.6 26.3 28
Cooling operation range °F 23~118.4
Heating operation range °F -4~75.2
Simultaneous Cooling and Heating 23~75.2
Airflow Rate CFM 6,890
Sound Pressure dBA 57 57 58
Fin Type Hydrophilic aluminium
Dimensions (WxHxD) inches 49-1/4×63-1/8×30-1/8
Net Weight lbs. 635
Refrigerant - R410a
Refrigerant Charge lbs. 28.7
Refrigerant Oil fl. Oz 169.1
Liquid Side Ø inch 3/8 1/2 1/2
Gas Side Ø inch 7/8 7/8 1-1/8
Refrigerant Max. Equivalent Pipe Length ft. 656
Piping Max. Height difference between IUs ft. 98
Max. Height difference for OU above IU ft. 230
Max. Height difference for OU below IU ft. 360
Max. Amount of IUs connected to OU - 13 16 20
<4> = 460 V, 3 ph, 60Hz
<6> = 220 V, 3 Ph, 60 Hz

* Rated per AHRI-1230 Standard conditions
* Nominal cooling capacities are based on the following conditions: indoor air temperature: 80.6°F DB, 66.2ºF WB, outdoor temperature: 95ºF DB, 75.2ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 68°F DB, 59ºF WB, outdoor temperature: 44.6ºF DB, 42.8ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber and 4.26 ft. above the floor.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

Optional Accessories
• TVR™ Select Outdoor unit centralized
controller TCONTCCM02A
• Digital ammeter

30 Tons unit

17 VRF-SLB010-EN
Indoor Units
4-way Cassette - 4TVC
• Integrated drain pump with 750 mm lift. • The adoption of the most advanced
3-dimensional screw fan:
• EXV kit is factory mounted on the unit.
- Reduces the air resistance
• Efficient air distribution
- Smooths the air flow and noise
• Fresh Air connection possible
level
• Digital tube displaying on the display board.
- Provides uniform air speed
LED can display the error code so it’s easier
distribution over the heat
to check malfunction
exchanger
• Ultra thin machine body for an easy
• Different optional color panels to integrate
installation and maintenance. (9-27 MBH à
into a design: White (standard), Gray, Blue
9 inches , 30-48 MBH à 11.8 inches)
and Black
• Reserved knock out spaces for ducting up
• Optional wireless controller or
to 50% of the air flow, hence supplying air to
wired controller
2 adjacent rooms

3-dimensional screw fan

Four-way Airflow

Wireless Wireless Wireless Wired Controller Wired Controller Wired Controller Wired Controller
*Optional Controllers

*Optional Controllers

Controllers Controllers Controllers

TCONTKJR90A TCONTKJR12B TCONTKJR120B TCONTKJR29B


TCONTRM05B TCONTRM02B TCONTRM01WA Heat Pump Heat Pump Heat Recovery Heat Pump
Heat Pump Heat Recovery Heat Pump

18 VRF-SLB010-EN
4-Way Cassette - 60 Hz
Model Numbers 4TVC0009C10 4TVC0012C10 4TVC0015C10 4TVC0018C10 4TVC0024C10
Power Supply V/Ph/Hz 208-230/1/60
Cooling Btu/h 9,000 12,000 15,000 19,000 24,000
Capacity
Heating Btu/h 10,000 13,500 17,000 21,000 27,000
Power Input W 100 115
Rated Current A 0.5 0.55

Air Flow (SH/H/M/L) CFM 680/499/451/377 710/509/444/387 781/681/562/441

Sound Pressure
(H/M/L) dB(A) 42/38/35 45/42/39
Dimensions
(W/H/D) inches 35-19/32×9-1/16×33-5/64
Unit
Net Weight lbs. 51 55
Dimensions
(W/H/D) inches 37-13/32×2-9/64×37-13/32

Front Panel Model


Number RAYPANELWHT001

Net Weight lbs. 11


Refrigerant Liquid Side Ø inch 1/4 3/8
Piping Gas Side Ø inch 1/2 5/8
Drainage Water Pipe
(OD) Ø inch 1-17/64

Model Numbers 4TVC0027C10 4TVC0030C10 4TVC0034C10 4TVC0038C10 4TVC0048C10


Power Supply V/Ph/Hz 208-230/1/60
Cooling Btu/h 27,000 30,000 34,000 38,000 48,000
Capacity
Heating Btu/h 30,700 34,000 37,000 42,000 54,000
Power Input W 115 180 220
Rated Current A 0.55 0.85 1

Air Flow (H/M/L) CFM 799/727/573/429 1057/936/765/642 1107/988/799/656

Sound Pressure
(H/M/L) dB(A) 45/42/39 48/45/43 50/47/44
Dimensions
(W/H/D) inches 37-13/32×2-9/64×37-13/32 35-19/32×11-13/16×33-5/64
Unit
Net Weight lbs. 57.3 65
Dimensions
(W/H/D) inches 37-13/32×2-9/64×37-13/32

Front Panel Model


Number RAYPANELWHT001

Net Weight lbs. 11


Refrigerant Liquid Side Ø inch 1/4 3/8
Piping Gas Side Ø inch 1/2 5/8
Drainage Water Pipe
(OD) Ø inch 1-17/64

* Rated per AHRI-1230 Standard conditions


* Nominal cooling capacities are based on the following conditions: indoor air temperature: 80ºF DB, 67ºF WB, outdoor temperature: 95ºF DB, 75ºF WB, equivalent ref. piping: 24.6 (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 70ºF DB, 60ºF WB, outdoor temperature: 47ºF DB, 43ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 4.6 ft. below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

19 VRF-SLB010-EN
Compact 4-way Cassette - 4TVB
Comfort Quick installation
• 360° efficient air distribution • Ultra thin body of 10.4 inches
for installation in tight ceilings
• Three level fan speed that meets different air
supply requirements • Light weight units are easy to
mount
• Optimum air flow thanks to the 3-Dimensional
Screw fan • Integrated drain pump that lifts
up to 500mm
- Reduced air resistance
- Smooths the air flow and noise level
Flexibility
- Provides uniform air speed distribution over • 1 panel size 25.5 inches x 25.5 inches that fits
the entire coil in standard ceiling grids for all 4 different sizes
• Built in Auto Restart
• Fresh Air connection possible

3-Dimensional Four-way Airflow


Screw Fan Compact
Cassette Panel

22.4 inches

24.8 inches

10.4 inches

Wireless Wireless Wireless Wired Controller Wired Controller Wired Controller Wired Controller
*Optional Controllers

*Optional Controllers

Controllers Controllers Controllers

TCONTKJR90A TCONTKJR12B TCONTKJR120B TCONTKJR29B


TCONTRM05B TCONTRM02B TCONTRM01WA Heat Pump Heat Pump Heat Recovery Heat Pump
Heat Pump Heat Recovery Heat Pump

20 VRF-SLB010-EN
Compact 4-Way Cassette – 60 Hz
Model Numbers 4TVB0007C10 4TVB0009C10 4TVB0012C10 4TVB0015C10
Power Supply V/Ph/Hz 208-230/1/60
Cooling Btu/h 7,000 9,000 12,000 15,000
Capacity
Heating Btu/h 8,000 10,000 13,500 17,000
Power Input W 50
Rated Current A 0.25
Air Flow (SH/H/M/L) CFM 313/234/172/127 317/240/182/136 372/292/211/155
Sound Pressure dB(A) 35.8/33.4/23.4 41.5/35.6/28.8
Dimensions (W/H/D) inches 22-7/16×10-15/64×22-7/16
Unit
Net Weight lbs. 37 40
Dimensions (W/H/D) inches 25-15/32×1-31/32×25-15/32
Front Panel Model Number RAYCMPCTPNL002
Net Weight lbs. 6.6
Liquid Side Ø inch 1/4
Refrigerant Piping
Gas Side Ø inch 1/2
Drainage Water Pipe (OD) Ø inch 63/64

* Rated per AHRI-1230 Standard conditions


* Nominal cooling capacities are based on the following conditions: indoor air temperature: 80ºF DB, 67ºF WB, outdoor temperature: 95ºF DB, 75ºF WB, equivalent ref. piping: 24.6 (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 70ºF DB, 60ºFWB, outdoor temperature: 47ºF DB, 43ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 4.6 ft. below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

21 VRF-SLB010-EN
Medium ESP Ducted Indoor - 4TVD
Comfort
• Three level fan speed that meets different air
supply requirements
• Low noise level thanks to the fan blade design
• Built in Auto Restart
• Standard long life filter

Quick installation
• Ultra thin body of 8.3 inches height for
installation in small ceiling pocket
• Light weight units are easy to mount

Flexibility
• Different installations patterns possible with
bottom return or ducted return

Wireless Wireless Wireless Wired Controller Wired Controller Wired Controller Wired Controller
*Optional Controllers

*Optional Controllers

Controllers Controllers Controllers

TCONTKJR90A TCONTKJR12B TCONTKJR120B TCONTKJR29B


TCONTRM05B TCONTRM02B TCONTRM01WA Heat Pump Heat Pump Heat Recovery Heat Pump
Heat Pump Heat Recovery Heat Pump

22 VRF-SLB010-EN
Mid Pressure Duct – 60 Hz
Model Numbers 4TVD0007C10 4TVD0009C10 4TVD0012C10 4TVD0015C10 4TVD0018C10
Power Supply V/Ph/Hz 208-230/1/60

Cooling Btu/h 7,000 9,000 12,000 15,000 19,000


Capacity
Heating Btu/h 8,000 10,000 13,500 17,000 21,000
Power Input W 75 115
Rated Current A 0.4 0.55
Air Flow (SH/H/M/L) CFM 340/310/240/190 -/500/390/340

Indoor External Static in. wg. 0.04-0.12


Pressure (H)
Sound Pressure (H/M/L) dB(A) 35/32/29 36/33/30 37/34/30
Dimensions (W/H/D) inches 31-7/64x8-17/64x25 39-49/64x8-1/4x25
Net weight lbs. 47 48 59
Liquid
Refrigerant Ø inch 1/4 3/8
Side
Piping
Gas Side Ø inch 1/2 5/8
Drainage Water Pipe (OD) Ø inch 1-1/4

Model Numbers 4TVD0024C10 4TVD0027C10 4TVD0030C10 4TVD0038C10 4TVD0048C10


Power Supply V/Ph/Hz 208-230/1/60

Cooling Btu/h 24,000 27,000 30,000 38,000 48,000


Capacity
Heating Btu/h 27,000 30,000 34,000 42,000 54,000
Power Input W 190 250 420 360
Rated Current A 0.9 1.15 1.95 1.65
Air Flow (SH/H/M/L) CFM -/620/530/480 1388/1345/1165/1013 -/790/690/610 -/1060/920/820 -/1120/970/830
Indoor External Static
Pressure (H) in. wg. 0.04-0.12 0.04-0.20 0.04-0.32 0.04-0.4

Sound Pressure (H/M/L) dB(A) 40/37/32 45.4/39.8/37 43/40/34 46/42/40


Dimensions (W/H/D) inches 39-49/64x10-5/8x25 46-29/64×10-5/8×30-33/64 48-27/64x10-5/8x30-33/64 50-25/32x11-13/16x34-1/16
Net weight lbs. 66 84 88 108
Refrigerant Liquid Side Ø inch 3/8
Piping Gas Side Ø inch 5/8
Drainage Water Pipe (OD) Ø inch 1-1/4 63/64 1-1/4

* Rated per AHRI-1230 Standard conditions


* Nominal cooling capacities are based on the following conditions: indoor air temperature: 80ºF DB, 67ºF WB, outdoor temperature: 95ºF DB, 75ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 70ºF DB, 60ºF WB, outdoor temperature: 47ºF DB, 43ºF DB, equivalent ref. piping: 24.6 ft. (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 3.28 ft. below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

23 VRF-SLB010-EN
High ESP Ducted Indoor - 4TVA
Comfort
• Three level fan speed that meets different air supply requirements
• Built in Auto Restart
• Air filter to be fitted inside return duct system

Flexibility
• Broad range of models up to 95 MBH
• External Static Pressure up to 1.12 inches WG

Wireless Wireless Wireless Wired Controller Wired Controller Wired Controller Wired Controller
*Optional Controllers

*Optional Controllers

Controllers Controllers Controllers

TCONTKJR90A TCONTKJR12B TCONTKJR120B TCONTKJR29B


TCONTRM05B TCONTRM02B TCONTRM01WA Heat Pump Heat Pump Heat Recovery Heat Pump
Heat Pump Heat Recovery Heat Pump

24 VRF-SLB010-EN
High Pressure Duct – 60Hz
Model Numbers 4TVA0024C10 4TVA0030C10 4TVA0038C10 4TVA0048C10 4TVA0055C10 4TVA0068C10 4TVA0095C10
Power Supply V/Ph/Hz 208-230/1/60
Cooling Btu/h 24,000 30,000 3,8000 48,000 54,000 72,000 96,000
Capacity
Heating Btu/h 27,000 34,000 42,000 54,000 60,000 84,000 11,0000
Power Input W 435 430 430 555 555 1490 1490
Rated Current A 2 2.05 2.05 2.5 2.5 6.5 6.5
Air Flow (H/M/L) CFM 1012/902/788 1326/1195/948 1294/1164/924 1746/1586/1453 1746/1586/1453 2260/2116/1748 2260/2116/1748
Indoor External Static
in. wg. 0.1(0.1- 0.78) 0.15(0.15- 0.78) 0.20(0.20-0.78) 0.8(0.20-1.12)
Pressure (H)
Sound Pressure (H/M/L) dB(A) 48/46/44.5 52/49/47 53/50/48 54/52/50 59/55/52
Dimensions
inches 37-31/64×16-17/32×27-11/64 51-3/16×16-1/2×27-13/64 56-13/16×18-1/2×31-57/64
Unit (W/H/D)
Net Weight lbs. 102 110 110 153 153 218 218
Refrigerant Liquid Side Ø inch 3/8
Piping Gas Side Ø inch 5/8 3/4
Drainage Water Pipe (OD) Ø inch 1-17/64

* Rated per AHRI-1230 Standard conditions


* Nominal cooling capacities are based on the following conditions: indoor air temperature: 80ºF DB, 67ºF WB, outdoor temperature: 95ºF DB, 75ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 70ºF DB, 60ºF WB, outdoor temperature: 47ºF DB, 43ºF DB, equivalent ref. piping: 24.6 ft. (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 3.28 ft. below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

25 VRF-SLB010-EN
Convertible - 4 TVX
Comfort
• Efficient air distribution with two directional airflow and wide
angle air flow
• Three level fan speed that meets different air supply requirements
• Low noise level
• Built in Auto Restart

Quick installation
• Installation under windows or ceilings
• Units are easy to mount
• Drain pipe connection left or right

Flexibility
• Modern and elegant appearance
• Can be installed vertically and horizontally

Wireless Wireless Wireless Wired Controller Wired Controller Wired Controller Wired Controller
*Optional Controllers

*Optional Controllers

Controllers Controllers Controllers

TCONTKJR90A TCONTKJR12B TCONTKJR120B TCONTKJR29B


TCONTRM05B TCONTRM02B TCONTRM01WA Heat Pump Heat Pump Heat Recovery Heat Pump
Heat Pump Heat Recovery Heat Pump

26 VRF-SLB010-EN
Convertible – 60 Hz
Model Numbers 4TVX0012C10 4TVX0015C10 4TVX0018C10 4TVX0024C10
Power Supply V/Ph/Hz 208-230/1/60
Cooling Btu/h 12,000 16,000 19,000 24,000
Capacity
Heating Btu/h 13,500 18,000 21,000 27,000
Power Input W 45 170 170 170
Rated Current A 0.25 0.8 0.8 0.8
Air Flow (H/M/L) CFM 353/283/235 441/383/324 441/383/324 441/383/324
Sound Pressure
dB(A) 40/38/36 43/41/38 43/41/38 43/41/38
(H/M/L)
Dimensions
38-31/32×25-63/64×7-63/64
Unit (W/H/D)
Net Weight 59 62 62 62
Liquid
Refrigerant Side Ø inch 1/4 3/8
Piping
Gas Side Ø inch 1/2 5/8
Drainage Water Pipe
Ø inch 5/8
(OD)

Model Numbers 4TVX0027C10 4TVX0030C10 4TVX0038C10 4TVX0048C10 4TVX0055C10


Power Supply V/Ph/Hz 208-230/1/60
Cooling Btu/h 28,000 30,000 38,000 48,000 54,000
Capacity
Heating Btu/h 30,700 34,000 42,000 54,000 60,000
Power Input W 195 195 265 265 425
Rated Current A 0.9 0.9 1.15 1.15 1.95
Air Flow (H/M/L) CFM 706/530/412 706/530/412 1165/1095/1018 1165/1095/1018 1354/1236/1060
Sound Pressure
dB(A) 45/43/40 45/43/40 47/45/42 47/45/42 52/50/48
(H/M/L)
Dimensions
50-25/64×7-63/64×25-63/64 65-3/4x26-49/64x9-39/64 65-3/4x26-49/64x11-7/32
Unit (W/H/D)
Net Weight 76 76 110 110 127
Liquid
Refrigerant Side Ø inch 3/8
Piping
Gas Side Ø inch 5/8
Drainage Water Pipe
Ø inch 5/8 63/64
(OD)

* Rated per AHRI-1230 Standard conditions


* Nominal cooling capacities are based on the following conditions: indoor air temperature: 80ºF DB, 67ºF WB, outdoor temperature: 95ºF DB, 75ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 70ºF DB, 60ºF WB, outdoor temperature: 47ºF DB, 43ºFWB, equivalent ref. piping: 24.6 ft. (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 3.28 ft. in front of the unit and 3.28ft. below the units (ceiling mounted). The microphone was located 3.28ft in front of the unit
and 4.92 ft. above the floor (low wall).
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

27 VRF-SLB010-EN
Wall Mounted Indoor Unit - 4TVW
Comfort
• Double air guides for optimum air distribution
• Three level fan speed that meets different air supply requirements
(7 -18 MBH)
• Built in Auto Restart 7 to 18 MBH
• Low noise 29dB(A) for 12 MBH model

Quick Installation
• LED display integrated, allows trouble shooting
• Multi position piping possibilities 7 to 18 MBH

Flexibility
• Slim design with an easy to clean mirror (7 to 18 MBH)

24-30 MBH

Wireless Wireless Wireless Wired Controller Wired Controller Wired Controller Wired Controller
*Optional Controllers

*Optional Controllers

Controllers Controllers Controllers

TCONTKJR90A TCONTKJR12B TCONTKJR120B TCONTKJR29B


TCONTRM05B TCONTRM02B TCONTRM01WA Heat Pump Heat Pump Heat Recovery Heat Pump
Heat Pump Heat Recovery Heat Pump

28 VRF-SLB010-EN
High Walls – 60 Hz
Model Numbers 4TVW0007C10 4TVW0009C10 4TVW0012C10 4TVW0015C10 4TVW0018C10 4TVW0024C10 4TVW0030C10
Power Supply V/Ph/Hz 208-230/1/60
Cooling Btu/h 7,500 9,500 12,000 15,000 19,000 24,000 30,000
Capacity
Heating Btu/h 8,500 11,000 13,500 17,000 21,000 27,000 34,000
Power Input W 35 35 35 55 55 100 100
Rated Current A 0.2 0.2 0.2 0.25 0.25 0.5 0.5
Air Flow (H/M/L) CFM 309/283/253 309/283/253 347/306/283 506/444/371 544/506/444 700/518/400 776/494/376
Sound Pressure (H/M/L) dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34 45/42/41 49/43/38
Dimensions
inches 36-1/32x11-27/64x9-1/16 42-13/64x12-13/32x9-1/16 49-7/32×12-51/64×9-41/64
Unit (W/H/D)
Net Weight lbs. 29 29 29 33 33 44 44

Refrigerant Liquid Side Ø inch 3/8


Piping Gas Side Ø inch 5/8
Drainage Water Pipe (OD) Ø inch 21/32

* Rated per AHRI-1230 Standard conditions


* Nominal cooling capacities are based on the following conditions: indoor air temperature: 80ºF DB, 67ºF WB, outdoor temperature: 95ºF DB, 75ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 70ºF DB, 60ºF WB, outdoor temperature: 47ºF DB, 43ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 3.28ft in front of the unit and 2.62ft below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

29 VRF-SLB010-EN
Indoor air quality depends on many design
factors and local codes.
The local ventilation regulations or ASHRAE 62.1 will define what ventilation ratio
is required per zone and per type of application.

The TVR SELECT system offers a high level of flexibility to adapt to any ventilation
standard and several design strategies can be followed.
1. Direct intake of indoor unit of pre-treated fresh air
2. 100% fresh air duct units
3. Separate dedicated outside air system CDQ + rooftop.

Layout Example: 100% Fresh Air - 4TVF


Outdoor Units
Flexibility
• External static pressure up to 1.124 inches WG
Indoor Unit Indoor Unit Comfort
Outdoor Air processing unit • Both fresh air filtration and heating or cooling
achieved with the same unit.
Air-conditioning Outside air supply
• Improved Indoor Air Quality.
• Efficient air distribution
• Standard filter

Wireless Wireless Wireless Wired Controller Wired Controller Wired Controller Wired Controller
*Optional Controllers

*Optional Controllers

Controllers Controllers Controllers

TCONTKJR90A TCONTKJR12B TCONTKJR120B TCONTKJR29B


TCONTRM05B TCONTRM02B TCONTRM01WA Heat Pump Heat Pump Heat Recovery Heat Pump
Heat Pump Heat Recovery Heat Pump

30 VRF-SLB010-EN
Fresh Air Units – 60 Hz
Model Numbers 4TVF0042C10 4TVF0048C10 4TVF0054C10 4TVF0072C10 4TVF0095C10
Power Supply V/Ph/Hz 208-230/1/60
Cooling Btu/h 36000 48000 54000 72000 96000
Capacity
Heating Btu/h 36000 41000 61000 68000 75000
Power Input W 630 970
Rated Current A 2.9 4.5 5.5
Air Flow (H/M/L) CFM 1261/1101/948 1889/1589/1295 1886/1619/1354 1766/1589/1324
Indoor External Static Pressure (H) in. wg. 0.20(0.20-0.78) 0.8(0.20-1.12)
Sound Pressure (H/M/L) dB(A) 54/52/50 54/53/51 55/54/52
Dimensions
inches 51-3/16×16-17/32×27-11/64 56-13/16×18-1/2×31-57/64
Unit (W/H/D)
Net Weight lbs. 153 153 245 245 251
Liquid Side Ø inch 3/8
Refrigerant Piping
Gas Side Ø inch 5/8
Drainage Water Pipe (OD) Ø inch 1-17/64

* Rated per AHRI-1230 Standard conditions


* Nominal cooling capacities are based on the following conditions: outdoor temperature: 95ºF DB, 75ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Nominal heating capacities are based on the following conditions: outdoor temperature: 32ºF DB, 30ºF WB, equivalent ref. piping: 24.6 ft. (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 4.6 ft. below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

31 VRF-SLB010-EN
Intelligent Management Control System
The TVR™ Select system can be controlled on different user levels, from the individual user level with the zone controllers to a
more centralized tenant by tenant control or a fully integrated building control PC system with a third party BMS control system

Wireless Controllers
Wireless Controller TCONTRM05B (for HP systems)
• Functions: LCD display, Clock, ON/OFF, Temp. setting, Mode setting, Fan speed setting, Timer,
Horizontal Swing, Vertical Swing, Air Direction
• Mode: Auto/Dry/Cool/Heat & Fan only
• Timer: 0 – 24 hrs timer setting
• Addressing function

TCONTRM05B

Wireless controller TCONTRM01WA (for HP systems)


• New Stylish design
• Functions: LCD display, Clock, ON/OFF, Temp. setting, Mode setting, Fan speed setting, Timer,
Horizontal Swing, Vertical Swing, Air Direction
• Mode: Auto/Dry/Cool/Heat & Fan only
• Timer: 0 - 24 hrs timer setting
• Addressing function
TCONTRM01WA
• Follow me: allows precise room temperature control using the Temperature sensor in
the controller

Wireless Controller TCONTRM02B (for HR systems)


• Auto-changeover mode for HR systems
• Functions: LCD display, Clock, ON/OFF, Temp. setting, Mode setting, Fan speed setting, Timer
• Addressing function

TCONTRM02B

32 VRF-SLB010-EN
Wired Controllers
Wired Controller TCONTKJR90A (for HP systems)
• New Stylish Design
• Functions: LCD display, Clock, ON/OFF, Temp. setting, Mode setting, Fan speed setting, Timer
• Mode: Auto/Dry/Cool/Heat & Fan only
• Timer: 0 – 24 hrs timer setting

TCONTKJR90A

Wired Controller TCONTKJR12B (for HP systems)


• Functions: LCD display, ON/OFF, Temp. setting, Mode setting, Fan speed setting, Timer, Swing
setting, Lock
• Mode: Auto/Dry/Cool/Heat & Fan only
• Timer: 0 – 24 hrs timer setting
• Follow me: allows precise room temperature control using the Temperature sensor in the controller
TKONTKJR12B

Wired controller TCONTKJR29B (for HP systems)


• New Stylish design
• Functions: LCD display, Clock, ON/OFF, Temp. setting, Mode setting, Fan speed setting, Timer,
Swing setting, Air Direction
• Mode: Silent/Auto/Dry/Cool/Heat & Fan only
• Timer: 0 - 24 hrs timer setting
TCONTKJR29B
• Addressing function
• Controller locking function
• Remote controller receiver function: controls the indoor unit using a wireless controller
• Air filter cleaning reminder: when the running time reaches the pre-set value the air filter icon will
light up
• Follow me: allows precise room temperature control using the Temperature sensor in the controller

Wired Controller TCONTKJR120A (for HR systems)


• Auto-changeover mode for HR systems
• Functions: LCD display, Clock, ON/OFF, Temp. setting, Mode setting, Fan speed setting, Timer

Note: Do not use HR controllers in HP systems in order to avoid mode conflict.

TCONTKJR120A

33 VRF-SLB010-EN
Centralized Controllers
Indoor unit Centralized Controllers
• TCONTCCM09A (for HP systems)
• TCONTCCM03HP (for HP systems)
• TCONTCCM03HR (for HR systems)
TCONTCCM09A
Functions:
• Group control
– TCONTCCM09 and 03 can control 64 indoor units
• Centralized ON/OFF
TCONTCCM03HP
• Mode setting, Temp. setting, Fan setting, Mode lock function
• Weekly timer setting (only for TCONTCCM09)
• Blue lit background LCD
• Lock mode

Outdoor Unit Centralized Controller TCONTCCM02A


• Controls 32 outdoor units and a PC can control 16 OU centralized controllers
• This controller cannot be connected directly to Mini TVR™ Select units.
• Centralized ON/OFF, Mode query, Temp. query, Fan query, Mode lock function
• Blue lit background LCD

TCONTCCM02A • Emergency stop contact or forced cooling start signal


• Maximum wiring length 3,281 feet

34 VRF-SLB010-EN
TVR™ Select Web Gateway and PC Network Control Software
TVR Select Web Gateway allows basic control of indoor and outdoor units through integrated software especially designed for
the TVR Select. The communication is done through a LAN connection that can be accessed either locally or remotely (VPN).
For advanced control functionality, the TVR Select PC Network Control Software increases the available functions including data
trending, custom reports and power consumption capabilities among others.

TVR Select Web Gateway


• Up to 3,937 ft. of wiring can be extended to 9843 ft. with a • TVR Select centralized controllers are not required
signal booster relay
• Energy consumption report (requires additional digital
• Manages up to 256 indoor units and 16 outdoor units ammeter TCONTDTS)
• Monitors the system online, records operational data, • TVR Select centralized controllers are not required
reports errors
• TVR Select Web Gate way is required
• Compatible with Windows XP and Windows 7
• Remote online service access possible via internet Digital Ammeter TCONTDTS
• One ammeter per Master Outdoor Unit or condensing
• TVR Select centralized controllers are not required
system

TVR Select PC Network Control Software • Needs to be connected to specific wiring terminals on
• Manages up to 1,024 indoor units and 64 outdoor units outdoor unit

• Monitors the system online, records operational data, • TVR Select Web Gateway and TVR Select PC Network
reports errors Control Software are required.
• Setpoint limit configuration, weekly timer, custom reports,
as-built drawings integration
• Compatible with Windows XP and Windows 7
• Remote online service access possible via internet

35 VRF-SLB010-EN
TVR™ SELECT WEB GATEWAY

36 VRF-SLB010-EN
TVR™ Select Cloud Server Controller
The new TVR Select Cloud Server Controller allows you to control the TVR Select system at your fingertips, literally! It has been
designed to manage remotely the TVR Select System, allowing extensive control of the indoor units via Web, HTTP, TCP or IP
access either through a LAN or WAN configuration. The cloud control software can be accessed using a computer, iPhone, iPad
or any other intelligent terminal anywhere and at any time. Controlling an HVAC system has never been easier before!

• Up to 3,280 ft. of wiring from the controller to the • Setpoint limits configuration, weekly timer, custom reports,
TVR Select system locking and unlocking functions
• Manages up to 64 indoor units • Compatible with Windows, Linux, UNIX, Mac, IOS
• Multiple Cloud Server Controllers can be accessed from the • TVR Select centralized controllers can be integrated
same internet access point (optional), but are not required for proper operation
• Versatile remote control through multiple intelligent
terminals as iPhone, iPad, Android, PC, etc.
• Monitors the system online, records
operational data, reports errors

37 VRF-SLB010-EN
Building Management Control
The TVR™ Select control network can combine several centralized controllers with a PC or external BMS systems such as Tracer
SC through BACnet™ or MODBUS interfaces to meet customers’ needs in different applications.

Outdoor Units
F1,F2,E K1,K2,E
TCONTCCM08A Indoor Units
MAX 4
TCONTCCM02A or TCONTCCM03 TCONTCCM02A

TCONTCCM03HP

Outdoor Units

BACnet/IP protocol

X,Y,E
TCONTCCM03HP
Indoor Units

BMS System P,Q,E

BACnet® Interface TCONTCCM08A

• This gateway connects through BACnet® to the TVR™ Select entire installation and other external
components through an existing BMS
TCONTCCM08A • Connects through Ethernet to BACnet®/IP
• 4 RS485 connections for connecting to 4 TVR Select centralized controllers

BACnet® is a registered trademark of ASHRAE.

MODBUS Interface TCONTMODBUS

• Integrates TVR Select systems to BMS systems through MODBUS.


• Controls up to 1024 indoor units and 64 outdoor units
• Transfers the information via the RTU mode
• Wide voltage 12-48VDC

TCONTMODBUS

38 VRF-SLB010-EN
Service Software
As part of our TVR™ Select portfolio, we introduce a service tool that allows you to diagnose and troubleshoot the system.

• Model number: TCONTSERVS.


• Real time display of outdoor unit
operating parameters 485A-l
K1,K2,E
• Description of error codes.

Other Accessories
Trane also offers other accessories to maximize customers’ comfort in different applications.

Air Handler Connection Kit


This kit allows you to integrate other indoor units to the TVR Select system. The kits includes the
TCONTAHUKIT1 control boards, EXV, sensors, and wired controller.

Three models available:


TCONTAHUKIT1 (14kW –one circuit)
TCONTAHUKIT2 (28 kW – two circuits)
TCONTAHUKIT3 (56 kW - two circuits)

Motion Sensor
• Turns off the system when it doesn’t sense movement in the room.
TCONTNAM09A

Hotel Inserting Card


• Model number: TCONTNAM05A
• ON-OFF control
• Auto-restart function

TCONTNAM05A

39 VRF-SLB010-EN
Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—
including Club Car®, Ingersoll Rand®, Thermo King® and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport