Ultrasonic Gas Flowmeter
Ultrasonic Gas Flowmeter
Ultrasonic Gas Flowmeter
Features
Optimum path placement – Single path meters
naturally have higher uncertainties than multi-path
meters due to the influence of different flow profiles
and Reynolds number. The MPU 200 however has
a unique lateral position of the path which minimizes
the effect of changing Reynolds number on the ac- MPU 200 Ultrasonic Gas Flowmeter
curacy of the meter.
Wet gas and contaminants – In addition to the variations due to pressure and temperature changes
minimum influence of Reynolds number, the path are compensated to ensure accurate, continuous
placement on the MPU 200 also makes it ideal for measurement.
applications containing wet gas or other types of con- WinScreen Software - Provides real-time logs,
taminants in the gas. The path is straight to avoid any trends, signal performance and parameter reports for
difficulties often experience with reflective designs operational, diagnostics and maintenance purposes.
in “dirty” applications. It is located above the center The user-friendly, Windows-based program displays
of the pipe to avoid any issues if liquids etc. gather meter information, including visualization of flow
in the bottom the pipe, and the design around the regime, on one screen.
transducer port is optimized for self drainage.
Digital Ultrasonic Signal Processing - The MPU Principle of Operation
200 is able to tolerate substantially higher ultrasonic The MPU 200 function is based on the well-established
noise levels than most other ultrasonic meters - up to acoustic transit time principle. The measurement prin-
20 times less sensitive to outside interference. ciple utilizes the fact that the direction and propagation
In-line Transducer Removal - Utilizing a transducer velocity of an ultrasonic pulse will be modified by the
retraction tool with isolation valves, transducers can flowing medium. An ultrasonic pulse propagating with
be easily and safely removed, if required, without the the flow will experience an increase in velocity while
need for process shut down and meter recalibration an ultrasonic pulse propagating against the flow will
after transducer reinsertion or replacement. experience a decrease in velocity. Turbulence and noise
Advanced Electronics - Extensive interface capabili- generated frequencies are filtered.
ties and high data speed allow for faster diagnostics MPU 200 measures the transit time of the ultrasonic
and the ability to operate and communicate from signal that is transmitted. The start of the transmis-
remote locations or over the Internet. sion and arrival of the correct signal is detected by the
Density Calculated from Sound Velocity - The software.
sound velocity is measured by the MPU 200 and is MPU 200 transducers are non-intrusive and flush
used for the following: comparison to a gas chromato- mounted ensuring minimum risk for clogging up by resi-
graph for meter health check; density calculations for dues in the flow. The transducer is fully encapsulated,
condition checking; and mass flow rate calculations. manufactured in titanium and is replaceable during
Pressure and Temperature Compensation - Meter operation and without the need for process shutdown
volume, signal path length and signal path angle and recalibration after replacement.