General Notes: As-Built Plan of One Storey Abdulin Store Building
General Notes: As-Built Plan of One Storey Abdulin Store Building
General Notes: As-Built Plan of One Storey Abdulin Store Building
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF THE 1. ALL WORKS HEREIN SHALL CONFORM WITH THE PRIVATION EDITION OF THE NATIONAL SANITARY CODE OF THE PHILIPPINES LOCAL
REVISED PLUMBING CODE OF THE PHILIPPINES, AND NATIONAL BUILDING CODE, AND THE RULES AND 10
ORDINANCES OF ZAMBOANGA CITY, ZAMBOANGA DEL NORTE, ZAMBOANGA DEL SUR. WC WATER CLOSET CO CLEAN OUT
REGULATIONS OF ZAMBOANGA CITY, ZAMBOANGA DEL NORTE, ZAMBOANGA DEL SUR.
2. ALL MATERIALS TO BE USED HEREIN SHALL BE BRAND NEW AND OF AN APPROVED TYPE FOR ITS LOCAL AND PURPOSE.
2. COORDINATE THE DRAWINGS WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS, THE ENGINEER SHALL LA LAVATORY VSTR VENT STACK THRU ROOF
2.1. COLD WATER LINE SHALL BE PE PIPE SDR-II PIPING SYSTEM.
BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND HEREIN.
2.2. USE PLUMBING FIXTURES WITH COMPLETE FITTINGS FOR WATER CLOSET AND LAVATORY, TILES SHALL BE CERAMIC GLAZED TILES
ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS, ANY RELOCATION REQUIRED FOR PROPER URI URINAL LVP LOOP VENT PIPE
3. FOR WALL AND UNGLAZED TILES FOR FLOORING, MARIWASA OR EQUIVALENT.
EXECUTION OF OTHER TRAPS SHALL BE WITH PRIOR.
2.3. USE 4" Ø PVC PIPE SERIES 1000 (MOLDEX EXTRA WITH O-RING OR APPROVED EQUAL) 3" Ø MOLDEX EXTRA PVC PIPE OR APPROVED
FD FLOOR DRAIN GV GATE VALVE
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH, AND INVERT ELEVATION EQUAL. FOR STORM DRAINAGE, DOWNSPOUTS, USE 10" Ø PVC OR CONCRETE PIPE FOR SURFACE DRAINAGE PIPES.
OF THE EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE CONTRACTOR.
3. PROVIDE CONTROL VALVE AT EVERY GROUP OF PLUMBING FIXTURES. PS PANTRY SINK CV CHECK VALVE
5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 2 MINIMUM UNLESS OTHERWISE SPECIFIED. 3.1. ALL PIPES MUST BE DUST-FREE AND MOISTURE-FREE BEFORE THEY ARE JOINED TO ENSURE A LEAK-PROOF SYSTEM SPECIALLY AT
JOINTS. GT GREASE TRAP GT GREASE TRAP
6. SIZES OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS. 3.2. SEPTIC TANK MUST BE OF THE APPROVED TYPICAL TYPE. QUALITY WORKMANSHIP SHALL BE DONE TO ENSURE WATER TIGHTNESS.
CB CATCH BASIN WATER LINE
3.3. SLOPE OF PIPING INSTALLATIONS FOE SEWAGE LINES MUST NOT EXCEED THE RATIO 1:20 BUT MIN. OF 1.
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE AND COORDINATE THE WORKS WITH THE
BUILDING OFFICIAL INVOLVED. 3.4. PROVIDE ROOF SLOPE FOR PROPER DRAINAGE TOWARDS ROOF DRAINS, ADEQUATE ROOF SLOPE SHALL BE MAINTAINED AT ENTIRE
S SHOWER SEWAGE LINE
ROOF AREA TO ELIMINATE STAGNANT WATER ACCUMULATION.
8. SEWER LINES EFFLUENT DISPOSAL POINT AND WATER LINE SERVICE CONNECTING POINT.
3.5. CONTRACTOR SHALL VERIFY THE EXISTING PIPES INVERT ELEVATION AT SITE.
T TAP DS DOWN SPOUT
ALL PIPES SIZES ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE SPECIFIED. 3.6. ALL WORKS HEREIN SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE SUPERVISION OF A DULY LICENSED MASTER PLUMBER.
F FAUCET
MATERIAL SPECIFICATIONS:
COLD WATER LINES PE PIPE SDR-II PIPING SYSTEM, (BUILDING CONSTRUCTION), EXPOSED PIPE
LINE SHOULD BE INSULATED. GALVANIZED IRON(G.I.) PIPE SCH. 40 CONFORMING
ASTM-A-120-80 "SUPRIME" BRAND OR EQUAL, PROVIDE COAL TAR WITH BURLAP FOR BURIED
PIPE.
DRAINAGE LINES 50 TO 100mm Ø "MOLDEX EXTRA" PVC PIPE SERIES 1000 II, 150mm Ø AND ABOVE
"MOLDEX EXTRA" PVC PIPE CLASS 35, CONCRETE DRAIN PIPE (CDP) OR APPROVED EQUAL
OUTSIDE BLDG.
SEWER LINES 50 TO 100mm Ø "MOLDEX EXTRA" PVC PIPE SERIES 1000 II, 150 MM Ø AND ABOVE
"MOLDEX EXTRA" PVC PIPE CLASS 35 OR APPROVED EQUAL.
VENT & DOWNSPOUTS 50 TO 100mm Ø "MOLDEX EXTRA" PVC PIPE SERIES 1000 II OR APPROVED
EQUAL.
FAUCET AERATORS INSTALL NIAGARA WATER SAVING DEVICE ON EVERY FAUCET OF LAV. &
KITCHEN SINK.
d
Roa
tonio THIS SITE
. An
San
Hall
nio Brgy.
PLUMBING FIXTURES San. Anto
1. INSTALL ALL PLUMBING FIXTURES FREE AND OPEN IN A MANNER TO ACCESS FOR
CLEANING, FURNISHING WITH BRACKETS, CLEATS, PLATES AND ANCHORS REQUIRED
nio Road
TO SUPPORT THE FIXTURES RIGIDLY IN PLACE. San. Anto
San. An
2. KEEP AWAY AT A SUFFICIENT DISTANCE BUT NOT LESS THAN
2 1INCH (12.7mm). ALL
SERVICE PIPES, VALVES AND FITTINGS FROM SURFACES AND LOCATION WHICH MAY
tonio Ro
REQUIRE FINISH COATS OR COVERING.
3. EXTEND THE PIPING TO ALL FIXTURES, OUTLETS AND EQUIPMENTS FROM REQUIRED
ad
GATE VALVES INSTALLED IN EACH BRANCH NEAR RISERS.
To Natio
SHUT-OFFS
nal High
1. PROVIDE THE ENTIRE SYSTEM WITH VALVES SO LOCATED THAT THE SYSTEM OR
PORTIONS OF IT CAN BE OPERATED, REPLACED AND REPAIRED, AS WELL AS
AFFORDING COMPLETE CONTROL OF THE WATER SUPPLY TO EACH GROUP OF THE
w
2. EXCAVATE TO REQUIRED DEPTHS AND GRADES, ALL EXCAVATIONS REQUIRED FOR THE
INSTALLATION OF PLUMBING AND DRAINAGE SYSTEM. WHEN ROCK IS ENCOUNTERED,
EXTEND EXCAVATION TO A DEPTH 150mm. BELOW THE PIPE BOTTOM AND BEFORE PIPE
IS LAID, FILL SAND AND OTHER APPROVED MATERIALS.
VICINITY MAP
SCALE NOT TO SCALE
3. LAY WATER SUPPLY PIPES AND SEWERS IN SEPARATE TRENCHES.
E GENERAL NOTES
E 1 SCALE NDTS
CHECKED AND REVIEWED BY: SEAL: PROJECT TITLE: DESIGNED AND DRAFTED BY: APPROVED BY: SHEET CONTENT: SHEET NO.:
AS-BUILT PLAN OF ONE STOREY ENGR. MARK RUBY D. OPAWON MRS. ABDULIN N. TABAÑERA AS INDICATED P
PRC NO.: VALIDITY:
ABDULIN STORE BUILDING OWNER 1 3
DATE:
PTR NO.:
ISSUED AT:
TIN: LOCATION:BRGY. SAN. ANTONIO, MANUKAN, ZAMBOANGA DEL NORTE ADD: BRGY. LIPAKAN, SALUG, ZDN ADD: BRGY. SAN. ANTONIO, MANUKAN, ZDN