HF-3 Instruction Manual

This document provides instructions for operating and configuring the HF-3/HF-5 manual frequency controller. It describes: 1. The front panel buttons and displays for controlling operation and accessing settings. 2. The parameter settings that define functions like relay behavior, acceleration/deceleration times, and input/output signal polarity. 3. How to save configured settings to memory and import from memory. 4. The terminal connections for controlling operation and interfacing with external devices.

Uploaded by

3R
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
431 views11 pages

HF-3 Instruction Manual

This document provides instructions for operating and configuring the HF-3/HF-5 manual frequency controller. It describes: 1. The front panel buttons and displays for controlling operation and accessing settings. 2. The parameter settings that define functions like relay behavior, acceleration/deceleration times, and input/output signal polarity. 3. How to save configured settings to memory and import from memory. 4. The terminal connections for controlling operation and interfacing with external devices.

Uploaded by

3R
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

HF-3 / HF-5 Manual

Digital Frequency Controller


Contents

1. Component Arrangement 2) RELAY


and Function ∙∙∙∙∙p3 a) PARA Setting Content
1) Product Front (rU / Er / S1)
2) Internal Terminal b) Wiring Method
3) External Volume (EXT VR)
2. Parameter ∙∙∙∙∙∙p4 4) Bowl/Hopper Interlocking
1) PARA Setting Table Control
2) PARA Setting Method
3) PARA Setting Sequence 6. Voltage/Frequency∙∙p7
1) Voltage and Frequency
3. Button Function ∙∙∙p5 Description
1) RUN 2) Voltage Setting
2) STOP 3) Manual Setting of Frequency
3) PARA 4) Automatic Setting of Frequency
4) V/F, ENT (Auto Tuning)
5) Encoder Volume 1. VS50 Specification
2. VS50 Installation Method
4. Saving and Importing of 3. Auto Tuning Method
Set Values ∙∙∙∙∙∙p5
1) Saving 7. External Dimension ∙p9
2) Importing
8. Fabrication Specification
5. Terminal Description and ∙∙∙∙∙∙∙∙∙∙∙p10
Wiring Method ∙∙∙∙p5
1) S1 control signal
(External 3 pin connect)
a) NO / NC
b) NPN / PNP
c) Control Terminal Wiring
Method


1. Component Arrangement and Function
1) Product Front

* RUN : Display of run/stop condition


F/B : Display of vibration sensor(VS50) operation
VOLT : Voltage display (0.0~200.0) CON : Control signal display
FREQ : Frequency display (40.0~400.0) OUT : Output display

* RUN - Run start button (Display of manual stop via lamp flashing)

* STOP - Manual stop button (Power outage maintained)

* PARA - Opening of time and function setting screen

* V/F, ENT - Voltage and frequency setting conversion, PARA


setting and selection. Auto tuning start button (ENT + 3 sec)

* Encoder Volume - Item selection and setting value input,


change in a 1.0 unit through rotation by pushing

* POWER - Power ON/OFF switch

2) Internal Terminal

* External Speed Control - Control of output voltage with


external volume and DC 0~5V(PARA setting)

* Relay Contact - Used as a Sol valve or for other purposes

* Vibration Sensor - Automatic detection of connection and


separation, display with a F/B lamp on a display window

* Bowl/hopper Interlocking Control


- Stop of hopper feeder when the bowl feeder stops

* Power Connect - Used by connecting the same parallel


power with the power terminal

* Power Terminal - AC 100V~240V power input terminal

* Output Terminal - Connected to the feeder


(Connected to the external connection)


2. Parameters
1) PARA Setting Table
Setting
Parameter Default Description
Range
Control Reverse Sets the polarity reversal of S1 control signal.
S1 no / nC nC
S1 POLE Control signal is On ☞ select operation or stop

On Delay ON DELAY on 0.1~9.9 2.0 On delay after On condition

Off Delay OFF DELAY oF 0.1~9.9 2.0 Off delay after Off condition

Accelerating Time ACCEL AC 0.1~9.9 1.0 Accelrating time of set voltage after On time

Decelerating Time DESEL dE 0.1~9.9 0.5 Stop and deceleration time after Off time

SOL Operation RELAY rE rU / Er / S1 rU Sets relay operation (Run/Abnormal/S1 signal)

Reverse RLY REVE rr no / nC no Relay operation reversal

Sensor Select SENSOR SE nP / Pn nP Selects the polarity of S1 control signal (NPN/PNP)

External Volume EXT VR Rd oF / on oF Selects to set and use the external voltage

Vibration Sensor F/B Fd on / oF on Selects and use the compensation function of vibrating sensor

Vibration Sensor F/B TIME Fb 01~99 10 Sets the compensation cycle of vibration sensor (10=0.1sec)

Lock Setting LOCK Lo oF / on oF Locks V/F and PARA setting function

2) PARA Setting Method


Press PARA button to display PARA item.
Turn Encoder Volume to change PARA item.
Press ENT button in the item to set to make setting value standby.
Turn Encoder Volume to set the value.
Press ENT button after setting to complete setting and switches to PARA item change.
Press PARA button after setting to switch to display screen.

3) PARA Setting Order

� � � � �
Open PARA window (PARA screen) Turn Volume to find PARA item Select the item to set

� � � �
Change the set value with Encoder Volume Screen after ENT has been changed Close PARA window


3. Button Function
1) RUN : Run start button (Power outage maintained)
2) STOP : Stops the operation compulsively, flashes the run display lamp, and becomes
an output stop condition.
3) PARA : Sets a time and operation method necessary for operation. (See the parameter item)
4) V/F ENT : Used as a voltage/frequency selection button on the V/F screen and as an ENT button
on the PARA screen.
5) Encoder Volume : An item selection and value setting volume.

4. Saving and Importing of Set Values


: Used to save a set value after completion of voltage/frequency and parameter setting.

1) Saving : Pushing the RUN button on the V/F display screen for 3 seconds flashes the 3 lamps
marked with M. Pushing the ENT button when M flashes saves it.
2) Importing : Pushing the STOP button on the V/F screen for 3 seconds flashes the 3 lamps
marked with R. Pushing the ENT button when R flashes imports the saved value.

5. Terminal Description and Wiring Method


1) S1 Control Signal (External 3 Pin Connect)
: Control signal terminal to run and stop the feeder, displayed with CON lamps.
a) NO / NC : Set as control inversion on the parameter to invert the control signal.
When controlled by a PLC, the A contact control after set as NO is favorable.
b) NPN / PNP : Set as sensor selection on the parameter to select the control signal input polarity.
NPN : Input of control signals by shorting IN and 0V
PNP : Input of control signals by shorting IN and +12
c) Control Terminal Wiring Method
+12 : A power output terminal used to supply power to the sensor when using a 3-wire type
sensor.(External power input prohibited)
IN : Control signal input terminal
0V : Common terminal (GND, COM)

A) 3-wire Type Sensor B) 2-wire Type Sensor C) Contact and TR


(NPN Selection)


2) RELAY
: A relay contact terminal installed for external signal and control that works according to the PARA setting.
a) PARA Setting Content : rU RUN, Er ERR, S1 Control signal
- RUN : The relay works during feeder operation.(The OUT display lamp ON)
- ERR : The relay works in case of an abnormality. (Used as signals to check abnormalities in the controller)
- S1 : S1 control signal ON Relay ON (Used to detect defects during bowl feeder operation)
b) Wiring Method
A) Sol Valve and Lamp B) Use of Contacts

※ Relay A, B, C → C : COM, A : A Contact, B : B Contact

3) External Volume (EXT VR)


: Control of speed with volume and voltage from the outside (Setting of whether to use it on the parameter)
Set the 0~200V output by supplying a 0~5V DC voltage between 0V(GND) and VR terminals.
a) Wiring Method

A) Installation of External Volume B) Supply of External Voltage

10KΩ

4) Bowl/Hopper Interlocking Control : H B 0V (HOPP BOWL 0V)


: The hopper feeder stops regardless of control signals when the bowl feeder stops.
a) Terminal Display Content
・H : Input terminal by shorting 0V and H (Input ON OFF delay time and then stops without condition)
・B : Connection of resistance(330Ω) in series with the TR COLLECT, and output terminal
to check stopping (Feeder stop Output ON)
・0V: Common terminal
b) Wiring Method
* Connecting the 0V and 0V with 2
strands of wires as shown in the
figure and connecting the B and H
stops the feeder B, and giving a
Stop signal to the feeder H stops
the feeder H.


6. Voltage/Frequency
1) Voltage/Frequency Description
V : Set the strength of vibrations, i.e. a force that the feeder coil pulls the upper plate of the feeder via.
F : Set the resonant frequency of the feeder, i.e. the frequency per second that the feeder coil pulls
the upper plate. The frequency with the highest strength of vibration is a resonant frequency.

* Principle of Feeder Vibration


If the feeder coil is supplied with sine waveforms of output, i.e. alternative waveforms of
+ electricity and - electricity, then the feeder coil pulls the upper plate when + electricity and
the upper plate returns via a spring force when - electricity.
The vibration of the feeder is generated by repetition of pulling and returning.
Voltage = Pulling force, Number of vibrations per second = Frequency
The resonant frequency varies depending on the structure of the spring and feeder,
so supplying suitable frequency for the spring and structure is setting of frequency.

2) Voltage Setting
: Turning the encoder volume with the VOLT-marked lamp ON changes the set voltage.

3) Manual Setting of Frequency


: Convert the voltage(VOLT) and frequency(FREQ) selection with the V/H ENT button.
Turning the encoder volume with the FREQ-marked lamp ON changes the set frequency.
Set the voltage to about 90.0V and convert into frequency setting.
Push and turn the encoder volume(varying in a 1.0 unit) and vary it up to 40Hz~400Hz
to find a resonant frequency band in which the feeder vibration is the strongest.

* Pushing the ENT button for 3 seconds turns ON the 3 lamps to start automatic conversion of
frequency. (Repeats 40Hz~400Hz)
Check the resonant frequency band and push the STOP button manually to stop it.

Turn the encoder volume to General(varying in a 0.1 unit) in a resonant frequency band to
check the starting point and final point of the resonant frequency band.
Set the frequency to the middle point of the resonant frequency band.
(Frequency setting completed)
Set the voltage to a strength of vibration necessary for voltage setting. (Voltage setting completed)

* If the voltage control range is large, then the frequency resonance band may differ.
Control the frequency finely through frequency setting to check whether it is at the middle point
of the resonance band.


4) Automatic Setting of Frequency(Auto Tuning)
: Install a vibration sensor VS50 to find the resonant frequency automatically and to use it
for the purpose of automatically compensating the vibration variation.

VS50 Specification
* Working power voltage : DC5V
* Working voltage range : DC3.5~6V
* Working temperature : -30℃~+85℃
* Cable length : 2M(basic), 3M, 5M
* Sensor operation outline : This works in a principle of measuring
the change in the condenser capacity
of a sensing cell that changes depending on motion.

VS50 Installation Method


a) Install the indicated arrow direction and the feeder vibration direction in the same direction.
b) Install it at a position where the change in feeder vibration can be well detected.
c) After installation, open the controller nameplate and connect it to the Connect at top
of the board body.
d) Detects it automatically and displays the connection and operation condition with the
F/B display lamp.
Displays the reading of vibration values with flashing of F/B lamps, and after completion,
operates the constant amplitude function.
The constant amplitude function stops during V/F setting.

Auto Tuning Method


1. Set the voltage to 90.0V, and push the ENT button for 3 seconds.
2. The 3 lamps are turned ON to start auto tuning. (40Hz~400Hz)
3. After finishing auto tuning, the auto tuning ends automatically.
4. Control the voltage(V) to control the strength of vibration at an available speed.

* If the voltage control range is large, then the frequency resonance band may differ.
Control the frequency finely through frequency setting to check whether it is at the middle point
of the resonance band.


7. External Dimension


8. Fabrication Specification

Item Content Remark


Model name HF-3 HF-5
Working
0 ~ 55℃
Environmental Temperature
specification Working
10 ~ 90%
Humidity

Power Voltage AC100V ~ AC240V, 50Hz ~ 60Hz Auto

Maximum Auto
3A 5A
Current Interception

Internal Fan None Installation Auto Operation


Electrical
specification Over-current
OL display Power OFF
Abnormality
Radiator
Stop at 70°
C or Higher
Temperature
Auto Return
Heater Overheating
OH Display
Abnormality

Control Type Frequency Setting, Voltage Control

Control
FET FET
Element
Output Output
0.0V ~ 200.0V
specification Voltage
Variable
40Hz ~ 400Hz
Frequency

Auto Tuning 40Hz ~ 400Hz

- Normal input of main power


Operating - RUN / STOP control with control signals Sensor and
Method - Opening of the output line during RUN Contact
prohibited
Operating
Time Setting 0.1 ~ 9.9sec
Specification
Interlocking
Bowl Feeder / Hopper Feeder
Control
Constant Installation of VS50, and automatic
Auto
Amplitude maintenance of set vibrations