314823114847pricebid Jharbandh
314823114847pricebid Jharbandh
314823114847pricebid Jharbandh
13.4.3 132 KV Single suspension H/W fitting suitable for single ACSR Moose Nos 18 0.00 0.00 0.00 0.00
13.4.4 33 KV Single Anchoring DoubleTension H/W fitting (without Turn buckle) suitable for Nos 18 0.00 0.00 0.00 0.00
twin ACSR Moose (250mm spacing)
13.4.5 33 KV Single Tension H/W fitting (without Turn buckle) suitable for single ACSR Nos 30 0.00 0.00 0.00 0.00
Moose
13.4.6 33 KV Single Suspension H/W fitting suitable for single ACSR Moose Nos 21 0.00 0.00 0.00 0.00
13.5 CLAMPS & CONNECTORS (100mm conductor grip)
13.5.1 132 KV 'T' Clamp for Twin Moose run with single Moose ACSR drop Nos 15 0.00 0.00 0.00 0.00
13.5.2 132 KV 'T' Clamp for Single Moose run with single Moose ACSR drop Nos 27 0.00 0.00 0.00 0.00
13.5.3 132 KV 'T' Clamp for Single Panther run with single Moose ACSR drop Nos 12 0.00 0.00 0.00 0.00
13.5.4 132 KV IVT Clamp (Single Moose) Nos 9 0.00 0.00 0.00 0.00
13.5.5 132 KV CT Clamp (Bimetallic, Single Moose) Nos 30 0.00 0.00 0.00 0.00
13.5.6 132 KV LA Clamp (Single Moose) Nos 12 0.00 0.00 0.00 0.00
13.5.7 132 KV CB Clamp (Single Moose) Nos 30 0.00 0.00 0.00 0.00
13.5.8 132 KV Isolater Pad Clamp (Single Moose) Nos 127 0.00 0.00 0.00 0.00
13.5.9 132 KV Isolator pad clamp for Section Isolators (Twin Moose type) Nos 6 0.00 0.00 0.00 0.00
13.5.10 132 KV PI Clamp (Single Moose) Nos 18 0.00 0.00 0.00 0.00
13.5.11 Spacer for Twin 132 KV Bus (Moose) Nos 36 0.00 0.00 0.00 0.00
13.5.12 33 KV 'T' Clamp for Twin Moose run with single Moose ACSR drop Nos 24 0.00 0.00 0.00 0.00
13.5.13 33 KV 'T' Clamp for Single Moose run with single Moose ACSR drop Nos 78 0.00 0.00 0.00 0.00
13.5.14 33 KV IVT Clamp (Single Moose) Nos 3 0.00 0.00 0.00 0.00
13.5.15 33 KV CT Clamp (Bimetallic, Single Moose) Nos 48 0.00 0.00 0.00 0.00
13.5.16 33 KV LA Clamp (Single Moose) Nos 27 0.00 0.00 0.00 0.00
13.5.17 33 KV CB Clamp (Single Moose) Nos 48 0.00 0.00 0.00 0.00
13.5.18 33 KV Isolator pad clamp Nos 138 0.00 0.00 0.00 0.00
13.5.19 33 KV Isolator pad clamp for Section Isolators (Twin Moose Type) Nos 12 0.00 0.00 0.00 0.00
13.5.20 33 KV Isolator pad clamp for Station Transformer Isolators ( Single ACSR Panther) Nos 12 0.00 0.00 0.00 0.00
13.5.21 33 KV PI Clamp Nos 22 0.00 0.00 0.00 0.00
13.5.22 Spacer for Twin 33 KV Bus (Moose) Nos 25 0.00 0.00 0.00 0.00
13.5.23 PG Clamp for ACSR Moose (Two Bolted) Nos 50 0.00 0.00 0.00 0.00
14 SUBSTATION EARTHING SYSTEMS
14.4 EARTH SPIKES & IT'S HARDWARES & FITTING
14.4.1 Earth Spike for 132KV side Columns : 23 Nos @ 7 mtrs length each Set 26 0.00 0.00 0.00 0.00
14.4.2 Earth spike for 33KV side Columns : 21 Nos @ 5 mtrs length each Set 22 0.00 0.00 0.00 0.00
14.4.3 Earthing Conductor for Earth Mat: 75 x 10 mm GI Flat. MT 24 0.00 0.00 0.00 0.00
14.4.4 Earthing Conductor for risers: 50 x 6 mm GI Flat MT 10 0.00 0.00 0.00 0.00
14.4.5 50 mm Heavy Duty GI Perforated Pipes, 3 mtrs long for treated earth pit Nos 163 0.00 0.00 0.00 0.00
14.4.6 40mm MS rod 3 mtrs long for non treated earth pit Nos 72 0.00 0.00 0.00 0.00
G.I Cable Trays including G.I. support Angle suitable for different sections
15
i.e. Section: 2-2, 3-3 & 4-4 along with its accessories as per TS.
15.1 G.I Cable Trays(size: 450x75x2500mm) Mtrs 750 0.00 0.00 0.00 0.00
15.2 G.I Cable Trays(size: 300x75x2500mm) Mtrs 1000 0.00 0.00 0.00 0.00
15.3 G.I Cable Trays(size: 150x75x2500mm) Mtrs 750 0.00 0.00 0.00 0.00
15.4 Support G. I angle 50x50x6 mm for cable tray MT 1.5 0.00 0.00 0.00 0.00
SWITCH YARD STRUCTURES COLUMN & BEAM (LATTICE TYPE) FOR 132/33
16
KV CLASS INCLUDING FOUNDATION BOLTS & NUTS.
16.1 DIFFERENT TYPES OF COLUMNS WITH DETAILS
16.1.1 T1S - 132 KV(Nominal unit wt- 1.2 MT) =20 Sets MT 24.00
16.1.2 T4S - 132KV (Nominal unit wt- 0.95 MT) =6 Sets MT 5.70
16.1.3 T8S - 33KV(Nominal unit wt- 0.83 MT) = 10 Sets MT 8.30
16.1.4 T9S - 33KV(Nominal unit wt- 0.6 MT)=12 Sets MT 7.20
16.2 DIFFERENT TYPE OF BEAMS WITH DETAILS
16.1.1 G1 - 132 KV(Nominal unit wt- 0.62 MT) = 20 Sets MT 12.40
16.1.2 G2 - 132 KV(NOMINAL UNIT WT- 0.9 MT) =4 Sets MT 3.60
16.1.3 G6 - 33KV (NOMINAL UNIT WT- 0.53 MT) = 4 Sets MT 2.12
16.1.4 G4 - 33KV(NOMINAL UNIT WT- 0.4 MT) =8 Sets MT 3.20
16.1.5 G4X - 33KV (NOMINAL UNIT WT- 0.52 MT) =4 Sets MT 2.08
16.3 TOTAL WEIGHT OF COLUMN & BEAM MT 68.60 0.00 0.00 0.00 0.00
SWITCH YARD EQUIPMENT STRUCTURES (LATTICE TYPE) FOR 132/33 KV
16.4
CLASS INCLUDING FOUNDATION BOLTS & NUTS.
16.4.1 Structure for 132KV CT (Unit Weight - 214.546 Kg) =15 Nos MT 3.22
16.4.2 Structure for 132KV IVTs (Unit Weight - 231.195 Kg) =9 Nos MT 2.08
16.4.3 Structure for 132KV Surge Arrester (Unit Weight - 179.893 Kg) =12 Nos MT 2.16
16.4.4 132 KV Single Isolator without Earth Switch (Unit weight - 658.767 Kg) = 9 Nos MT 5.93
16.4.5 132 KV Double Isolator without Earth Switch (Unit Weight - 979.10 Kg) = 2 Nos MT 1.96
16.4.6 132 KV Double Isolator with Earth Switch (Unit Weight - 1120.559 Kg) = 2 Nos MT 2.24
16.4.7 Structure for 132KV BPI (Unit Weight - 309.883 Kg) =18 Nos MT 5.58
16.4.8 Structure for 33KV CT (Unit Weight - 148.80 Kg) =18 Nos MT 2.68
16.4.9 Structure for 33KV IVTS (Unit Weight - 124.336 Kg) =3 Nos MT 0.37
16.4.10 Structure for 33KV LAs (Unit Weight - 148.8 Kg) =6 Nos MT 0.89
16.4.11 33 KV Single Isolator without Earth Switch (Unit weight - 294.893 Kg) = 18 Nos MT 5.31
16.4.12 33 KV Single Isolator with Earth Switch(Unit weight - 324.8 Kg) = 5 Nos MT 1.62
16.4.13 Structure for 33KV BPI (Unit Weight - 148.80 Kg) =22 Nos MT 3.27
16.4.14 Structure for 33KV HG Fuse (Unit Weight - 245 Kg) =2 Nos MT 0.49
16.5 TOTAL WEIGHT OF EQUIPMENT STRUCTURE MT 37.80 0.00 0.00 0.00 0.00
MT 5.32 0.00 0.00 0.00 0.00
16.6 Total weight of GI Nuts and bolts for the above Column, Beam & structures
16 GENERAL EQUIPMENT & SUBSTATION ACCESSORIES
POWER CABLES, 1.1KV, XLPE/PVC ARMOURED, ALUMINIUM CONDUCTOR
16.1
(As per Specification)
16.1.1 XLPE 3.5 CX300 mm2 Mtrs 300 0.00 0.00 0.00 0.00
16.1.2 XLPE 3.5 CX185 mm2 Mtrs 300 0.00 0.00 0.00 0.00
16.1.3 XLPE 3.5 CX120 mm2 Mtrs 200 0.00 0.00 0.00 0.00
16.1.4 PVC 3.5 CX70 mm2 Mtrs 200 0.00 0.00 0.00 0.00
16.1.5 PVC 3.5 CX35 mm2 Mtrs 1800 0.00 0.00 0.00 0.00
16.1.6 PVC 4 CX 16 mm2 Mtrs 700 0.00 0.00 0.00 0.00
16.1.7 PVC 4 CX 6 mm2 Mtrs 1500 0.00 0.00 0.00 0.00
16.1.8 PVC 2CX 6 mm2 Mtrs 2000 0.00 0.00 0.00 0.00
16.2 CONTROL CABLES, 1.1 KV, PVC, STRANDED COPPER (As per specification)
16.2.1 2 CX 2.5 mm2 Mtrs 1500 0.00 0.00 0.00 0.00
16.2.2 4 CX 2.5 mm2 Mtrs 12000 0.00 0.00 0.00 0.00
16.2.3 5 CX 2.5 mm2 Mtrs 1500 0.00 0.00 0.00 0.00
16.2.4 7CX 2.5 mm2 Mtrs 4500 0.00 0.00 0.00 0.00
16.2.5 10 CX 2.5 mm2 Mtrs 4000 0.00 0.00 0.00 0.00
16.2.6 12 CX 2.5 mm2 Mtrs 3500 0.00 0.00 0.00 0.00
16.2.7 16 CX 2.5 mm2 Mtrs 500 0.00 0.00 0.00 0.00
16.2.8 19 CX 2.5 mm2 Mtrs 1500 0.00 0.00 0.00 0.00
SINGLE CORE 1.1KV, PVC UN-ARMOURED COPPER CONDUCTOR: for
16.3 connection from Battery Set to Battery Charger and from Battery Charger to DCDB on
cable tray / HDPE pipe/PVC pipe etc
16.3.1 1CX 120 mm2 BAT TO BAT CHARGER & CHARGER TO DCDB Mtrs 200 0.00 0.00 0.00 0.00
SUPPLY OF POWER TRANSFORMER, NCTs & OTHER ACCESSORIES AS PER
17
TECHNICAL SPECIFICATION
17.1 132/33 KV, 20 MVA Yn Yn Power Transformer as per TS Nos 2 0.00 0.00 0.00 0.00
The following type tests shall be carried out in presence of Purchaser‟s Lot 1 0.00 0.00 0.00 0.00
representative on entire quantity of the Transformer.
(a) Temperature Rise Test.
(b) Measurement of Zero Sequence Impedance.
17.2 (c) Auxiliary Power Consumption..
(d) Vacuum Test
(e) Pressure Test
(f) IP-55 Test
The following type test shall be carried out in presence of Purchaser‟s representative No 1 0.00 0.00 0.00 0.00
17.3 on one unit out of the Lot at the discretion of the purchaser.
(a) Dynamic Short Circuit (DSC)Test charges including post DSC tests
Charges for Transportation of Transformer from the Factory site to the Location for Lot 1 0.00 0.00 0.00 0.00
17.4 Dynamic Short Circuit (DSC)Test & back to Factory and other incidental charges if
any.
FIRE FIGHTING (Nitrogen Injection Type Fire Prevention & Extinguishing System): Lot 2 0.00 0.00 0.00 0.00
17.5 Suitable for 20 MVA, 132/33 KV Power Transformer as per Technical Specification &
latest standard.
17.6 One set of spares as per TS for Two nos Transformers Lot 1 0.00 0.00 0.00 0.00
SUPPLY OF STATION TRANSFORMER & OTHER MATERIALS FOR MEETING
18 THE AUXILIARY SUPPLY OF THE SUB-STATION AS PER TECHNICAL
SPECIFICATION
18.1 Station Transformer - 33KV/433V, 250 KVA (As per Specification) Nos 2 0.00 0.00 0.00 0.00
HG Fuse set- for 33kV side of the station transformer including the mounting Sets 2 0.00 0.00 0.00 0.00
18.2 insulators, channels complete in all respect (each set comprises three single HG fuse)
19 SUBSTATION AUTOMATION SYSTEM (IEC 61850) Lot 1 0.00 0.00 0.00 0.00
Gateway Panel: for Sub-Station Automation (in PRP on FO as per the specification &
indicative drawing) system (for All 132 & 33 KV side bays) and with other accessories,
comprising:
1. HMI servers (Main & Stand By)
2. DR PC
3. Redundant Gateway
4. Color Laser jet Printer-1Nos
5. Dot Matrix Printer-1Nos
6. Ethernet Switches (with 20% spares Port) for process bus & station bus
19.1 7. LIU
8. Multimode glass fibre Doublle jacket armoured optical cables
9. Red boxes
10. Inverters - 3 KVA (Main & Stand by)
11. Furniture (Operator desk 1 Nos & Chair-6Nos)
12.Full HD LED TV for display etc as per TS, including all type of accessories &
special cables like F.O patch cord & armoured FO cables of adequate length etc
required for the system in all respect as per latest IEC 61850- ED-2 standard & as per
technical
Aux specification.
BCU for station auxiliary system (Station AC, station DC, Lighting, Firefighting, DG Nos 1 0.00 0.00 0.00 0.00
19.2 set, Air conditioning etc): as per requirement compliant to IEC 61850 - ED-2 protocol
with PRP on FO. Power Supply 220V DC.
19.3 GPS System with IRIG-B/SNTP/PTP with VDU (Clock) Nos 1 0.00 0.00 0.00 0.00
132KV Level Protection Panel- Single Panel Twin Bay Type (2 Bays in One
19.4
Panel) with IEC 61850-ED-2 PRP on FO
132KV feeder Protection Panel: Feeder-1 & 2 in one panel Nos 1 0.00 0.00 0.00 0.00
Numerical Distance protection relay, BCPU and other auxiliary relays as per
19.4.1
requirement compliant to IEC 61850-ED-2 protocol with PRP on FO. Power Supply
220V DC.
132KV Transformer Protection Panel: Transformer-1 & 2 in one panel Nos 1 0.00 0.00 0.00 0.00
Numerical Differential protection relay, BCPU and other auxiliary relays as per
19.4.2
requirement compliant to IEC 61850-ED-2 protocol with PRP on FO. Power Supply
220V DC.
132KV Buscoupler Protection Panel: BCPU and other auxiliary relays as per Nos 1 0.00 0.00 0.00 0.00
requirement compliant to IEC 61850-ED-2 protocol with PRP on FO. Power Supply
19.4.3 220V DC.
33KV Level Protection Panel- Single Panel Twin Bay Type (2 Bays in One
19.5
Panel) with IEC 61850-ED-2 PRP on FO
33KV Feeder Protection Panel: with BCPU & with other Auxiliary relays as required Nos 3 0.00 0.00 0.00 0.00
as per the scheme compliant to IEC 61850 - ED-2 protocol with PRP on FO. Power
Supply 220V DC.
19.5.1 33KV Buscoupler Protection Panel: with BCPU & with other Auxiliary relays as
required as per the scheme compliant to IEC 61850-ED-2 protocol with PRP on FO.
Power Supply 220V DC.
Note: 5 Nos. of Line Feeder Bays and 1 Bus coupler to be considered in 3 Panels.
33KV Transformer protection panel: with BCPU, numerical REF & with other Auxiliary Nos 1 0.00 0.00 0.00 0.00
relays as required as per the scheme, compliant to IEC 61850-ED-2 protocol with PRP
19.5.2 on FO. Power Supply 220V DC.
Main Lighting Distribution Board (Indoor Type): Having 250A MCCB for Set 1 0.00 0.00 0.00 0.00
20.1.3
Incomers with source-1, Source-2 & Bus coupler.
20.1.4 Indoor Lighting Distribution Board (Indoor Type) Set 1 0.00 0.00 0.00 0.00
Emergency Lighting Distribution Board (Outdoor type): The ELDB should be Set 1 0.00 0.00 0.00 0.00
20.1.5
supplying to 20% of switchyard lights, each of 132KV and 33KV Switchyard.
20.1.6 Indoor Receptacle Board Set 1 0.00 0.00 0.00 0.00
Bay Marshalling Kiosk (Outdoor type): 1 BMK for 3 nos 132KV bays and 1 BMK for 4 Nos 5 0.00 0.00 0.00 0.00
20.1.7
nos 33KV bays
20.1.8 Console Box for Switchyard Lighting (Outdoor type) Nos 2 0.00 0.00 0.00 0.00
20.1.9 Console Box for Street Lighting (Outdoor type) Nos 2 0.00 0.00 0.00 0.00
20.1.10 Console Box for Colony Supply (Outdoor type) Nos 1 0.00 0.00 0.00 0.00
20.1.11 Switchyard Receptacle Board for Transformer Oil Filtration (Outdoor type) Nos 1 0.00 0.00 0.00 0.00
20.1.12 Switchyard Receptacle Board for Welding & Other Emergency (Outdoor type) Nos 2 0.00 0.00 0.00 0.00
CT Out Door Console Boxes ( 132 KV CT-5 Nos, 33 KV CT-8 Nos) (Outdoor type) Nos 13 0.00 0.00 0.00 0.00
20.1.13
PT Out Door Console Boxes (132 KV IVT-3 No., 33 KV IVT-1 No.) (Outdoor type) Nos 4 0.00 0.00 0.00 0.00
20.1.14
20.1.15 Outdoor kiosk for Station Transformer (Outdoor type) Nos 2 0.00 0.00 0.00 0.00
ACDB for Yard Kiosk (Indoor Type): LT supply to Protection panels, Kiosk lighting, AC Nos 1 0.00 0.00 0.00 0.00
20.1.16
etc made of 2mm CR sheet
DCDB for Yard Kiosk (Indoor Type): DC supply to Protection panels having source-1 & Nos 1 0.00 0.00 0.00 0.00
20.1.17
2 with auto changeover facility, made of 2mm CR sheet.
20.2 DC SYSTEM
220 V DC DISTRIBUTION BOARD (Indoor Type): Having 63A DC MCCB for Set 1 0.00 0.00 0.00 0.00
20.2.1 Incomers, Bus Coupler with interlock, E/F (EARTH LEAKAGE), UNDER & OVER
VOLTAGE and shall be SAS compliant.
20.2.2 220 V DC Emergency Lighting Distribution Board (Indoor Type) Set 1 0.00 0.00 0.00 0.00
20.2.3 Battery cells (2.2V), 350 AH Plante Type for 220 V DC (107 Nos + 3 Nos spare) Set 1 0.00 0.00 0.00 0.00
Battery Charger For 350 Ah Plante Type Battery, 107 cells, 2.2V, Trickle charge volt- Set 1 0.00 0.00 0.00 0.00
2.25V(Float & Float Cum Boost). The Charger ON/OFF status, input/output voltage,
20.2.4
output current, associated charger protection signals shall be provided for integration
with SAS.
21 ACCESSORIES FOR OPGW SYSTEM With OPGW cable
21.1 24 Fibre Optic Approach cable along with HDPE Pipes Km 1.00 0.00 0.00 0.00 0.00
Optical line Terminal Equipment(OLTE) -STM4 type SDH equipment with integrated No 1 0.00 0.00 0.00 0.00
MUX & tributary cards for speech & data ports for interfacing of Speech & data
21.2
which should be compatible with existing OPTCL system including all accessories
for successful commissioning.
Supply of FODP(Fibre Optic Distribution Panel)48 F: Indoor type,rack mounted with No 1 0.00 0.00 0.00 0.00
21.3
FCPC coupling and pig tails(DWSm Fibre)
21.4 48 V, 300 AH, maintenance free VRLA Battery set. Set 1 0.00 0.00 0.00 0.00
21.5 SMPS based battery charger of 75A suitable for 48V VRLA battery. No 1 0.00 0.00 0.00 0.00
21.6 48V DCDB Nos 1 0.00 0.00 0.00 0.00
21.7 Earth Flat, Cable Tray, Foundation rail, Junction Box,. Set 1 0.00 0.00 0.00 0.00
SUB STATION LIGHTING (AS PER SPECIFICATION AND APPROVED
22
DRAWINGS) (Switch yard and other street area)
SWITCHYARD LIGHTING- Includes supply of LED type Fixtures & Lamps of Set 46 0.00 0.00 0.00 0.00
reputed make (Philips/CGL/Bajaj/Havells/Crompton) with switch gear, GI Conduit etc.
22.1
(Lighting fixtures are to be fixed rigidly on the Column at a suitable height so that the
required lux can be achieved.
STREET LIGHTING: Includes supply of GI Tubular Poles as per Technical
Specification, LED type Fixtures & Lamps of reputed make
22.2 (Philips/CGL/Bajaj/Havells/Crompton) with switch gear, GI Conduit etc. (100 watt
each) for Street Light. (To be provided along the roads inside the substation area).
LED LIGHTING FIXTURES: of reputed make (Philips / CGL / Bajaj / Crompton / Set 25 0.00 0.00 0.00 0.00
22.2.1
Havells) other make approved by OPTCL). (100 watt each) for Street Light.
GI Tubular Pole: (410-SP-24: IS 2713-Part-II-1980 or latest) Length of pole- 8.5 Set 25 0.00 0.00 0.00 0.00
mtrs, weight- 158 Kgs.
22.2.2 (The GI Tubular Poles shall have provision of a GI Junction Box with suitable covers
at a height of 1 mtr from the ground. The Junction Box shall have provision of fuses,
bus bars, TBs for cable In & Out)
Lighting provision for other Areas: Suitable for (a) Main Gate Lighting (2 nos of 70 Lot 1 0.00 0.00 0.00 0.00
Watt LED), (b) Garden Lighting (4 nos of 70W LED) with necessary post top lantern
22.3
with pole , (c) Control Room Building peripheral Lighting (4 nos of 70W LED).
23 AIRCONDITIONING
AIR CONDIONER: Supply of 2T capacity Split Air Conditioning Units (Dual Inverter, Set 12 0.00 0.00 0.00 0.00
five star or better type latest model) with copper condensor having remote
temperature & operation control facility. AC Control Panel made of 2mm CR sheet,
having suitable outgoing (one outgoing for one AC & with overload control gear) &
wiring materials with 15 amp socket & plug for each unit of AC etc to complete (As
per specification) for Control/SAS Room, ACDC Room Communication room, office
23.1 room & Conference room .
The ACs in the ACDC Room(04 nos) shall run in tandem i.e 2 ACs at a time
for 4 hours each. Suitable control arrangement shall be made using 24hr
timer for start and stop. Similarly, for Control Room (2 ACs) and
Communication Room (2ACs), one AC at a time for 4 hours each. One AC
each in office rooms(2 nos), Conference Room, Transit Room.
23.2 AC for Switchyard Kiosk Set 2 0.00 0.00 0.00 0.00
FIRE FIGHTING SYSTEM(PORTABLE AND WHEEL MOUNTED Sets FOR
CONTROL ROOM,EQUIPMENT LIKE TRANSFORMER AND OTHER AREAS AS
24
PER TECH SPEC(REFER TS-INST TO BIDDER BEFORE DESIGN-SL NO 16-
ANNEXURE - I)
24.1 FOAM TYPE-9 LTRS Nos 4 0.00 0.00 0.00 0.00
24.2 DRY CHEMICAL POWDER(TROLLEY MOUNTED)- 22.5 KGS Nos 4 0.00 0.00 0.00 0.00
24.3 DRY POWDER TYPE - 5 KGS Nos 4 0.00 0.00 0.00 0.00
24.4 CO2 - 4.5 KGS Nos 10 0.00 0.00 0.00 0.00
24.5 CO2 - 9 KGS Nos 10 0.00 0.00 0.00 0.00
24.6 CO2 (TROLLY MOUNTED)- 22.5 KGS Nos 4 0.00 0.00 0.00 0.00
24.7 Water type- 9 LTRS Nos 4 0.00 0.00 0.00 0.00
24.8 Foam type - 50 LTR Nos 4 0.00 0.00 0.00 0.00
24.9 FIRE BUCKET (6 NOS IN EACH STAND) WITH STAND and Canopy Set 6 0.00 0.00 0.00 0.00
Maintenance Testing Equipment (All equipment shall comply to the TS and as Lot 1 0.00 0.00 0.00 0.00
25
per list below)
100KV Automatic Transformer Oil Breakdown Voltage test set (Megger- OTS 100AF / Nos 1
25.1
Baur- DTA 100C)
Nos 1
25.2 10KV Insulation Tester with 15m test lids (Megger- S1-1068 / Sonel-MIC 10K1)
Digital Earth Tester (Facility with soil resistivity measurement) (Megger-DET2/3 / Nos 1
25.3
Sonel MRU-120 / Fluke 1625)
25.4 Digital Multimeter (Megger / Fluke) Nos 2
25.5 Digital Clamp meter (Megger/Fluke/Motwane) Nos 1
Leakage current clamp meterAC & DC both (30mA / 300mA / 30A / 300A) Nos 1
25.6
(Megger/Fluke/Kyoritsu)
25.7 SF6 Gas Leakage Detector (Kika/DILO) Nos 1
25.8 Oil sampling Bottle- Stainless Steel, Capacity- 1 Ltr (Make- Tosin) Nos 6
Fibre Glass Discharge / Earth Rod: Grip up to 50mm, Min height-16ft, rubber grip, 35 Set 6
25.9
sq.mm copper cable (1 set- 3 cables, 1 set of rod, carry bag) (Bemico)
25.10 Electrical Rubber Hand Gloves Pairs 4
25.11 Portable High Beam Light (rechargeable) Nos 2
25.12 Desktop Computer: (HP/Lenovo/Dell) Set 2
Processor-Intel Core i5 10th Gen or better
RAM- 8GB DDR4 or More
ROM- 512GB SSD
Monitor- 21.5" FHD (1920 x 1080) or higher
Graphics- Intel UHD
OS- Genuine Windows 10 or 11 Pro
25.13 Webcam- 720P Logitech Nos 2
25.14 Speaker- 2 nos Stereo type Nos 2
25.15 UPS 600VA (APC/V Guard) Nos 2
Nos 1
25.16 Laser Printer, Black & White, Duplex printing (print, scan & copy) (HP/Canon/Epson)
Other Tools And Plants (T&P'S) Requirement (As Per details below). The T & P lot 1 0.00 0.00 0.00 0.00
26
materials shall be of Taparia/Bosch/Stanley make.
26.1 D Spanner Set (6mm – 42mm) Set 1
26.2 Ring Spanner Set (6mm – 42mm) Set 1
26.3 Box spanner set Set 1
26.4 Pipe Wrench 24 " Nos 1
26.5 Pipe Wrench 18 " Nos 1
26.6 Adjustable spanner -12”(slide wrench) Nos 1
26.7 Adjustable spanner -18”(slide wrench) Nos 1
26.8 Insulated cutting plier (standard size) Nos 1
26.9 Nose Plier (standard size) Nos 1
27 Screw Driver set
27.1 12” Plain head Nos 2
27.2 12” star head Nos 2
27.3 8” Plain head Nos 2
27.4 6” plain head Nos 2
27.5 6” star head Nos 2
27.6 Set of screw driver cum line tester Set 1
27.7 Allen Key set Set 1
27.8 Files
27.9 Flat File-12” Nos 1
28 Flat file-6” Nos 1
28.1 Round file- 12” Nos 1
28.2 Round file- 6” Nos 1
28.3 Hammer with Handle
28.4 1 lb Nos 2
28.5 2 lb Nos 1
28.6 ½ lb Nos 2
28.7 Steel Tape (Any reputed make)
28.8 5Mtr Nos 1
28.9 30Mtr Nos 1
29 Crow bar (Any reputed make)
29.1 5ft Nos 2
29.2 3ft Nos 2
29.3 Oil Cane (Any reputed make) Nos 2
29.4 Hand Drill Machine (impact drill) with key (Make-Bosch/Black & Decker) Nos 1
Vacuum Cleaner (at least 15L) (Make-Eureka Forbes / Black & Decker / Phillips / No 1
29.5
Karcher)
Stand Fan (450mm sweep,1400rpm, 240V AC) (Make-Crompton, Bajaj, Havells, Nos 2
29.6
Almonard, Usha)
29.7 De-Mineralised Plant of 30 L/Hr for Making Distilled Water for Battery Banks. Set 1
Self supproted cum extendable Ladder-25ft (FRP) of Adequate Height to be used for Nos 1
29.8
Maintenance of Equipment Inside Switchyard.
Self supproted platform Ladder- 12feet (FRP) of Adequate Height to be used for Nps 1
29.9
Maintenance of Equipment Inside Switchyard.
30 20 Ltr Storage Water Cooler (Voltas/Bluestar only) Nos 1 0.00 0.00 0.00 0.00
31 Water Purifier (Kent/Aquaguard/ Nos 1 0.00 0.00 0.00 0.00
32 Supply of Office Furniture: Godrej make (As per details below). Lot 1 0.00 0.00 0.00 0.00
For Control Room, conference room, office rooms, Library, testing room etc
32.1
32.1.1 5ftX3ft executive table with drawer both sides Nos 4
32.1.2 4.5ft X 2.5ft Table with one side drawer Nos 7
Computer table suitable keeping monitor, CPU, UPS and printer with two nos Set 1
32.1.3
revolving arm chair suitable for computer use.
32.1.4 Executive revolving, adjustable (height) chairs with arm Nos 4
32.1.5 Cushion fixed “S” type steel chairs with arm Nos 16
32.1.6 6ftX3ft conference table Nos 1
32.1.7 Cushion arm steel chairs for conference table purpose. Nos 6
6ft height steel almirah (only with selves) for keeping records and other valuable Nos 3
32.1.8
items.
32.1.9 6ft height steel almirah with glass doors for library purpose Nos 2
6ft height (having minimum 6 lockers facility) steel cupboard with locking Nos 2
32.1.10
arrangement.
32.1.11 4ft steel rack (minimum three selves) for keeping the files and other items. Nos 8
32.2 For Communication Room
32.2.1 5ftX3ft executive table with drawer both sides Nos 1
32.2.2 Executive revolving, adjustable (height) chairs with arm Nos 1
32.2.3 Cushion fixed “S” type steel chairs with arm Nos 2
6ft height steel almirah (only with selves) for keeping records and other valuable Nos 1
32.2.4
items.
Insulating Mat: Best Quality & approved make (Confirming to IS:15652:2006) to be Nos 37 0.00 0.00 0.00 0.00
33
kept infront of all panels, boards etc.(2000X1000X3mm Size)
INDOOR LIGHTING OF STORE SHED, STORE ROOM & VEHICLE PARKING: It Lot 1 0.00 0.00 0.00 0.00
includes supply of LED Luminaire(Philips/CGL/Bajaj/Havells/ Crompton) with switch
gear, Conduit (Polycab, Finolex, V-Guard), modular type switches (Legrand/
Schneider/ Havells/ Anchor/L & T/Cona), copper wires (Finolex / Havells / KEI/ RR
34 Kabels / Polycab),power sockets with switches & other required materials for
succesful illumination of the area/rooms. (No. of LED Lighting fixtures are to be
calculated based on the illumination design considering the required lux level
indicated in the technical spec & fixing of the same rigidly on the suitable height
either ceiling & wall as required.)
CCTV: Supply, Installation, Commissioning, Testing for IP Based CCTV Surveillance Lot 1 0.00 0.00 0.00 0.00
System (Server Based approach) with 4TB Hard Disk, Day/Night Cameras for Control
Room, entire Switchyard areas covering the boundaries, entry and exit points of the
Sub-Station, suitable for 360 degree movement with all necessary hardware fittings
for monitoring and surveillance of entire grid s/s. The CCTV system shall be able to
be integrated with the SAS system.
Numbers of such cameras (each type of camera viz. PTZ, Bullet & Dome) and other
35
hardware/ accessories are to be calculated as per the standard practice & its
installations at the strategic locations.
Tentative requirement of cameras:
(a) Switchyard Area: 03 nos. PTZ cameras.
(b) Control room Building:
(i) MCCDB (AC & DC Room):01 No. (Dome Camera),
(ii) Control Room: 01 No. (Dome Camera)
(iii) Main Entrance of Control Room: 01 No. (Bullet Camera)
A (c) Main Gate: 1 no. Bullet
TOTAL Camera.
OF SUBSTATION-2A (SUPPLY) 0.00
DESCRIPTION OF ITEMS BASIC PRICE PER CGST @ 9% OGST @ 9% TOTAL PRICE TOTAL PRICE FOR
SUPPLY OF MANDATORY SPARES FOR THE FOLLOWING UNIT (Taxable PER UNIT PER UNIT PER UNIT ( In THE QUANTITY
SR. No. Unit Qty Value) In Rs (INTRA- (INTRA- Rs)
EQUIPMENTS.
(As per Technical Specification) STATE) STATE)
145 KV, 800-400-200 A, 31.5 KA, 4 core Single Phase Current Transformer (3 Nos PS 0.00 0.00 0.00 0.00
1 Nos 2
CLASS & 1 No. 0.2s CLASS)
2 145 KV, 1250A, 31.5KA, ISOLATORS
2.1 Fixed & Moving Contact Assembly set Set 1 0.00 0.00 0.00 0.00
3 120 KV Metal Oxide Surge Arrester, 10 KA, Class III Nos 2 0.00 0.00 0.00 0.00
4 145 KV, 2 CORE, Single Phase IVT Nos 2 0.00 0.00 0.00 0.00
5 132 KV Bus Post Insulator Nos 2 0.00 0.00 0.00 0.00
6 145KV, 3150A, 40KA, SF6, CIRCUIT BREAKER
6.1 Density Monitoring System Set 1 0.00 0.00 0.00 0.00
6.2 Closing Coil Nos 4 0.00 0.00 0.00 0.00
6.3 Tripping Coil Nos 4 0.00 0.00 0.00 0.00
6.4 SF6 Gas Filling Device Nos 1 0.00 0.00 0.00 0.00
7 33KV Current Transformer
36 KV,800-400-200,25KA,3 CORE SINGLE PHASE CURRENT TRANSFORMER(2 NOS PS 0.00 0.00 0.00 0.00
7.1 Nos 3
CLASS & 1 NO. 0.2s CLASS)
36 KV, 800-400-200, 25KA, 4 CORE SINGLE PHASE CURRENT TRANSFORMER (3 NOS 0.00 0.00 0.00 0.00
Nos 3
PS CLASS & 1 NO. 0.2s CLASS)
8 36 KV,1250A,25KA,ISOLATORS
8.1 Fixed & Moving Contact Assembly set Set 1 0.00 0.00 0.00 0.00
9 30 KV, Metal Oxide Surge Arrester, 10KA, class II Nos 3 0.00 0.00 0.00 0.00
10 36 KV, 2 Core Single Phase IVT (1 core 3P & 1 core 0.2s) Nos 1 0.00 0.00 0.00 0.00
11 36KV, 1250A,25KA,VACUUM CIRCUIT BREAKER
11.1 One complete Pole Assembly of Circuit Breaker in dust proof and safe packing. Nos 3 0.00 0.00 0.00 0.00
11.2 Closing Coil Nos 4 0.00 0.00 0.00 0.00
11.3 Tripping Coil Nos 4 0.00 0.00 0.00 0.00
12 33 KV Bus Post Insulators Nos 3 0.00 0.00 0.00 0.00
13 BUS BAR & CIRCUIT MATERIALS
13.1 132KV TENSION & SUSPENSION INSULATORS
13.1.1 120KN Porcelain Anti Fog type Disc Insulators Nos 78 0.00 0.00 0.00 0.00
13.1.2 90KN Porcelain Anti Fog type Disc Insulators Nos 16 0.00 0.00 0.00 0.00
13.2 33KV TENSION & SUSPENSION INSULATORS
13.2.1 120KN Porcelain Anti Fog type Disc Insulators Nos 26 0.00 0.00 0.00 0.00
13.2.2 90KN Porcelain Anti Fog type Disc Insulators Nos 5 0.00 0.00 0.00 0.00
14 ACSR CONDUCTOR
14.1 ACSR Moose Conductor Mtrs 250 0.00 0.00 0.00 0.00
14.2 ACSR Dog Conductor Mtrs 100 0.00 0.00 0.00 0.00
1 0.00 0.00 0.00 0.00
Clamps & Connectors for 132 KV & 33 KV (Each type Three Nos) for Sl No- 14.3.8 to
15 14.3.29 of Substation Sypply section. The exact qty of each item under this shall be Set
mentioned by the agency and shall be incorporated in the P.O.
16 BATTERY CHARGER
One complete set of Electronic cards of the Battery Charger for 300AH, 48V VRLA 1 0.00 0.00 0.00 0.00
16.1 Battery Set. The exact qty of each item under this shall be mentioned by the agency Set
and shall be incorporated in the P.O.
One complete set of Electronic cards of the Battery Charger for 350AH, 220V Plante 1 0.00 0.00 0.00 0.00
16.2 type Battery Set. The exact qty of each item under this shall be mentioned by the Set
agency and shall be incorporated in the P.O.
17 Spares for Protection relay Panels (As installed in C/R Panels)
17.1 Distance Protection Relay Nos 1 0.00 0.00 0.00 0.00
17.2 Differential Protection Relay Nos 1 0.00 0.00 0.00 0.00
17.3 BCPU Nos 1 0.00 0.00 0.00 0.00
1 0.00 0.00 0.00 0.00
Other Auxiliary Relays (Each 1 No. of Different Type) the exact qty of each item under
17.4 Set
this shall be mentioned by the agency and shall be incorporated in the P.O.
B TOTAL SUPPLY OF MANDATORY SPARES FOR SUB-STATION 0.00
TOTAL OF SUPPLY COMPONENT OF THE WORKS CONTRACT FOR
C 0.00
SUBSTATION AND MANDATORY SPARE (A+B)
PART-II, SCHEDULE-2A(FOR LINE)
DESCRIPTION OF ITEMS(SCHEDULE-2A-LINE) BASIC PRICE PER CGST @ 9% OGST @ 9% TOTAL PRICE TOTAL PRICE FOR
UNIT (Taxable PER UNIT PER UNIT PER UNIT ( In THE QUANTITY
Sl No SUPPLY OF FOLLOWING EQUIPMENT & MATERIALS UNITS QUANTITY
Value) In Rs (INTRA- (INTRA- Rs)
(As per Technical Specification)
STATE) STATE)
SUPPLY of Following type tested Lattice type Galvanized steel tangent /
Angle tower with stubs and cleats , different type of G.I HT Nuts & Bolts,
1 washer, spring washer for the towers ,hanger and all accessories, tower
super structure complete including step bolts. Supply of black bituminous
paint for three coats up to a height of 500mm above the cooping(legs &
bracing members). All Supply should confirm to the Technical Specification.
1.1 PA TYPE TOWERS (Nominal unit weight 3.484 MT)- 12 Nos MT 41.81
1.1.1 +3 EXTENSION to PA type Towers (Nominal unit weight- 0.637 MT)-8 Nos MT 5.10
1.1.2 +6 EXTENSION to PA type Towers (Nominal unit weight- 1.346 MT)-0 Nos MT 0.00
1.2 PB TYPE TOWERS (Nominal unit weight 5.102 MT)-7 Nos MT 35.71
1.2.1 +3 EXTENSION to PB type Towers (Nominal unit weight 1.038 MT)-3 Nos MT 3.11
1.2.2 +6 EXTENSION to PB type Towers (Nominal unit weight- 1.152 MT)-0 Nos MT 0.00
1.3 PC TYPE TOWERS (Nominal unit weight- 6.174 MT)-11 Nos MT 67.91
1.3.1 +3 EXTENSION to PC type Towers (Nominal unit weight- 1.15 MT)-1 Nos MT 1.15
1.3.2 +6 EXTENSION to PC type Towers (Nominal unit weight- 2.416 MT)-2 Nos MT 4.83
1.4 UR TYPE TOWERS (Nominal unit weight- 13.348 MT)-0 Nos MT 0.00
1.4.1 +6 mtr Extension to UR type Tower (Nominal Weight- 4.147 MT)-0 Nos MT 0.00
1.5 OC TYPE TOWERS (Nominal unit weight- 9.967 MT)-0 Nos MT 0.00
1.5.1 +15 mtr Extension to OC type Tower (nominal Weight- 0 MT)-0 Nos MT 0.00
1.4 TEMPLATES
1.4.1 PA (Nominal unit weight- 0.492 MT)(1 nos.) MT 0.49
1.4.2 PB (Nominal unit weight- 0.624 MT)(1 no.) MT 0.62
1.4.3 PC (Nominal unit weight- 0.876 MT)(1 no.) MT 0.88
1.4.4 UR (Nominal unit weight-1.476 MT)(0 nos) MT 0.00
1.4.5 OC (Nominal unit Weight- 1.006 MT)(0 Nos) MT 0
1.5 WEIGHT OF THE STRUCTURES & Templates including Tower Stub MT 161.62 0.00 0.00 0.00 0.00
1.7 Weight of different type G.I Nuts and Bolts MT 7.00 0.00 0.00 0.00 0.00
Supply of the following tower accessories as per technical specification and
2.0
as directed by the engineer in charge.
2.1 EARTHING DEVICE Nos 30 0.00 0.00 0.00 0.00
2.2 DANGER BOARD Nos 30 0.00 0.00 0.00 0.00
2.3 NUMBER PLATE Nos 30 0.00 0.00 0.00 0.00
2.4 PHASE PLATE Nos 180 0.00 0.00 0.00 0.00
2.5 BIRD GUARD Nos 72 0.00 0.00 0.00 0.00
2.6 ANTICLIMBING DEVICE Nos 30 0.00 0.00 0.00 0.00
2.7 CIRCUIT PLATE Nos 60 0.00 0.00 0.00 0.00
2.8 COUNTERPOISE EARTHING Nos 0 0.00 0.00 0.00 0.00
Supply of following POWER CONDUCTORS in the proposed 132 kV lines
3.0 with provision for 1.5 % sag and wastage as per the technical specification
and as per the instruction of the engineer in charge.
3.1 ACSR PANTHER CONDUCTOR km 53.01 0.00 0.00 0.00 0.00
4.0 POWER CONDUCTOR ACESSORIES
4.1 For ACSR PANTHER
4.1.1 VIBRATION DAMPER Nos 576 0.00 0.00 0.00 0.00
4.1.2 MID SPAN JOINT Set 24 0.00 0.00 0.00 0.00
4.1.3 REPAIR SLEEVE Set 20 0.00 0.00 0.00 0.00
4.1.4 P A ROD FOR ACSR PANTHER Set 72 0.00 0.00 0.00 0.00
4.1.5 PG CLAMP FOR ACSR PANTHER Set 0 0.00 0.00 0.00 0.00
Supply of the following Long Rod type Poricilain insulators for 132KV as
5.0 per the technical specification and as per the instruction of the Engineer in
charge.
5.1 120KN Porcelain Longrod Insulators Nos 336 0.00 0.00 0.00 0.00
5.2 90KN Porcelain Longrod Insulators Nos 108 0.00 0.00 0.00 0.00
Supply of the following hard ware fittings suitable for ACSR Panther
6.0
conductors as per the technical specification.
6.1 For ACSR PANTHER
6.1.1 Single suspension Hard wares fittings suitable for 90 KN Long Rod insulator. Nos 36 0.00 0.00 0.00 0.00
6.1.2 Double suspension Hard wares fittings suitable for 90 KN Long Rod insulator. Nos 36 0.00 0.00 0.00 0.00
6.1.3 Single tension Hard wares fittings suitable for 120 KN Long Rod insulator. Nos 108 0.00 0.00 0.00 0.00
6.1.4 Double tension Hard wares fittings suitable for 120 KN Long Rod insulator. Nos 60 0.00 0.00 0.00 0.00
6.1.5 “D” Shackle Nos 216 0.00 0.00 0.00 0.00
6.1.6 Hanger Nos 72 0.00 0.00 0.00 0.00
6.1.7 U'-Bolt. Nos 12 0.00 0.00 0.00 0.00
Supply of OPGW Fibre Optic Cable & Hard ware for Speech , data &
7 protection
7.1 48 fibre (DWSM) OPGW fibre optic cable. Km 8.705 0.00 0.00 0.00 0.00
OPGW hardware set like suspension Assembly,Tensin Assembly(Dead end assembly, 0.00 0.00 0.00 0.00
Pass through assembly) ,Vibration Damper,Down Lead Clamp Assemblies for 24/48 Set 1.00
7.2 Fibre(DWSM) OPGW,Joint Box
8 High Resolution Binacular(NICON COOLPIX P900) Nos 1.00 0.00 0.00 0.00 0.00
D TOTAL OF LINE(SCHEDULE-2A) 0.00
E Total of Supply (Schedule- 2A-SS+2A-TL)(C+D) 0.00
NOTE
1 Before filling up rate/amount etc. in the schedules bidders are requested to read carefully the instruction given in Vol-I of Bidding Document.
2 Bidders are required to fill up only blue shaded cells.
3 Bidders are requested to not leave any column blank. If any column is left blank it shall be considered that amount against those items are included in any other item and the total amount for that
4 Basic Price (taxable value) for supply includes Packing & Forwarding, freight & insurance etc. excluding GST with full Input Tax Credit)
ODISHA POWER TRANSMISSION CORPORATION LTD
NAME OF THE WORK:-
PACKAGE -CPC-55/2022-23 Construction of 2 x 20 MVA, 132/33 KV Grid Sub-station with SAS , Jharbandh at Sankri and associated 132 KV
132/33 KV S/S AT JHARBANDH & ASSOCIATED 132 KV LILO LILO line on 132 KV Padampur - Nuapada Line (Approx. Line Length- 8.705 Kms.)
LINE NOTICE INVITING TENDER-NIT NO. -CPC-55/2022-23 & BID DOCUMENT No.:Sr. G.M- CPC- e-Tender-
Jharbandh S/S - 55/2022-23
(ERECTION) PRICE BID FOR WORKS CONTRACT (SAC CODE - 995423): SCHEDULE - VII-B - PART -II ERECTION
COMPONENT OF THE WORKS CONTRACT-( PACKAGE- 55/2022-23)
NAME OF
BIDDER
Qty
FOLLOWING EQUIPMENTS (As per Technical Specification) MENT (Taxable Value) (INTRA-STATE) (INTRA- Rs)
In Rs STATE)
1 2 3 4 5 6= {5*9%} 7= {5*9%} 8= {5+6+7} 9= {8*4}
A ELECTRICAL WORKS
SUB-STATION
145 KV, 800-400-200 A, 31.5 KA, 4 core Single Phase Current Transformer (3 Nos PS CLASS & 1
1 Nos 15 0.00 0.00 0.00 0.00
No. 0.2s CLASS)
2 145 KV, 1250A, 31.5KA, ISOLATORS
2.1 Single Isolator without Earth Switch Nos 9 0.00 0.00 0.00 0.00
2.2 Double Isolator with Earth Switch Nos 2 0.00 0.00 0.00 0.00
2.3 Double Isolator without Earth Switch Nos 2 0.00 0.00 0.00 0.00
120 KV Metal Oxide Surge Arrester, 10 KA, Class III with insulated base supports and surge
4 Nos 12 0.00 0.00 0.00 0.00
counter
5 145 KV, 2 Core, Single Phase IVT Nos 9 0.00 0.00 0.00 0.00
6 132 KV Bus Post Insulator Nos 18 0.00 0.00 0.00 0.00
145KV, 3150A, 40KA, SF6 Circuit Braker with supporting Structure. Facilities for integration with
7 Nos 5 0.00 0.00 0.00 0.00
SAS as per the site requirement.
36 KV,800-400-200,25KA,3 CORE SINGLE PHASE CURRENT TRANSFORMER(2 NOS PS CLASS & 1
7.1
NO. 0.2s CLASS)
Nos 18 0.00 0.00 0.00 0.00
36 KV, 800-400-200, 25KA, 4 CORE SINGLE PHASE CURRENT TRANSFORMER (3 NOS PS CLASS &
7.2
1 NO. 0.2s CLASS)
Nos 6 0.00 0.00 0.00 0.00
8 36 KV,1250A,25KA,ISOLATORS
8.1 Single Isolator without Earth Switch Nos 18 0.00 0.00 0.00 0.00
8.2 Single Isolator with Earth Switch Nos 5 0.00 0.00 0.00 0.00
8.3 Beam Mounted Single Isolator without Earth Switch Nos 4 0.00 0.00 0.00 0.00
30 KV, Metal Oxide Surge Arrester, 10KA, class II with insulated base supports and surge counter
9 Nos 27 0.00 0.00 0.00 0.00
10 36 KV, 2 Core Single Phase IVT (1 core 3P & 1 core 0.2s) Nos 3 0.00 0.00 0.00 0.00
36 KV, 1250A, 25KA, Vaacuum Circuit Breaker with supporting Structure. Facilities for integration
11 Nos 8 0.00 0.00 0.00 0.00
with SAS as per the site requirement.
12 33 KV Bus Post Insulator Nos 28 0.00 0.00 0.00 0.00
13 BUS BAR STRINGING: Supply of labour, T&P and other necessary
arrangements for stringing of bus bar conductors, hoisting of single or double
insulator strings, Single or Double Hard-wares Fittings, Clamp & connectors, as
per requirements, Jumpers, connections to Equipments, testing, commissioning
etc. as per the instruction of Engineer-in charge.
13.1 Single conductor/Phase Mtr 2500 0.00 0.00 0.00 0.00
13.2 Twin Conductor /Phase Mtr 500 0.00 0.00 0.00 0.00
13.3 Single ACSR Dog conductor / phase (including supply of sockets) Mtr 100 0.00 0.00 0.00 0.00
14 EARTH SPIKES & IT'S HARDWARES & FITTING
14.1 FOR 132KV SIDE : 26 Nos @ 7 Mtrs with two nos of earth risers from the Main
Set 26 0.00 0.00 0.00 0.00
earth mat connected to its bottom.
14.2 FOR 33 KV SIDE: 22 Nos @ 5 Mtrs with two nos of earth risers from the earth
Set 22 0.00 0.00 0.00 0.00
mat connected to its bottom.
15 SUB-STATION EARTH-MAT
Substation earth-mat:
(a) The Soil resistivity for the substation area is to be measured and approved by
OPTCL.
(b) The Earth Mat design and layout is to prepared based on the soil resistivity
and approved by OPTCL.
(c) Laying of earth-mat conductors of Hot dip galvanized flats of size
75X10mm, excavation of earth for laying of earth flat as per approved design &
drawing, welding/jointing, application of two coats of bituminous Paint, wrapping
of HT Tape etc of ground conductors & etc with back filling and good compaction.
The spacing between the earth conductor not more than 5 Mtrs (both way) and
to be buried at depth of 700mm from the finished ground level.
15.1 (d) 40 mm MS solid rod: Provision of grounding driven 40 mm MS Solid rod, along
the periphery of the switchyard i.e near the fencing.
(e) 50 mm,3 mtr long Heavy duty perforated GI pipes: for treated earth pits
(with details of treatment as per IS).
(f) Provision of water taps inside the switch yard areas and peripheral for treated
earth pit for watering the treated earth pits.
Note: The no. of treated and un treated earth pits are to be done as per the
practice and as indicated in the drawing for different equipment.
(g) The erection of risers of size 50 x 6 mm / 75 x 10 mm GI flats including
welding/jointing, application of two coats of bituminous Paint, wrapping of HT
Tape etc as per requirement. This is as per approved drawing and specification.
75x10 MM GI FLAT: The flat is also to be laid from the earth mat up to the
15.1.1 Mtrs 4000 0.00 0.00 0.00 0.00
foundation level.
50x6 MM GI FLAT: for Raiser from the foundation level to equipment, structure,
15.1.2 columns and up to the bottom of spikes etc.). Each equipment strructure & Mtrs 4200 0.00 0.00 0.00 0.00
Columns shall be connected to earth at two separate points.
40 MM MS Rod for Non-Treated earth pit electrode shall be connected to the main
15.1.3 Nos 72 0.00 0.00 0.00 0.00
earth mat.
50MM GI Pipe for Treated Earth Pit: Electrode with chamber & cover, shall be
15.1.4 connected to the main earth mat. The resistance of each earth pit shall be Nos 163 0.00 0.00 0.00 0.00
recorded in presence of the Engineer In charge.
G.I Cable Trays including support GI angle suitable for different sections i.e.
16
Section: 2-2, 3-3 & 4-4 along with its accessories as per TS.
16.1 G.I Cable Trays(size: 450x75x2500mm) Mtrs 750 0.00 0.00 0.00 0.00
16.2 G.I Cable Trays(size: 300x75x2500mm) Mtrs 1000 0.00 0.00 0.00 0.00
16.3 G.I Cable Trays(size: 150x75x2500mm) Mtrs 750 0.00 0.00 0.00 0.00
16.4 Support G. I angle 50x50x6 mm for cable tray MT 1.5 0.00 0.00 0.00 0.00
SWITCH YARD STRUCTURES COLUMN & BEAM (LATTICE TYPE) FOR
17
132/33 KV CLASS INCLUDING FOUNDATION BOLTS & NUTS.
17.1 DIFFERENT TYPES OF COLUMNS WITH DETAILS
17.1.1 T1S - 132 KV(Nominal unit wt- 1.2 MT) =20 Sets MT 24.00
17.1.2 T4S - 132KV (Nominal unit wt- 0.95 MT) =6 Sets MT 5.70
17.1.3 T8S - 33KV(Nominal unit wt- 0.83 MT) = 10 Sets MT 8.30
17.1.4 T9S - 33KV(Nominal unit wt- 0.6 MT)=12 Sets MT 7.20
17.2 DIFFERENT TYPE OF BEAMS WITH DETAILS
17.2.1 G1 - 132 KV(Nominal unit wt- 0.62 MT) = 20 Sets MT 12.40
17.2.2 G2 - 132 KV(NOMINAL UNIT WT- 0.9 MT) =4 Sets MT 3.60
17.2.3 G6 - 33KV (NOMINAL UNIT WT- 0.53 MT) = 4 Sets MT 2.12
17.2.4 G4 - 33KV(NOMINAL UNIT WT- 0.4 MT) =8 Sets MT 3.20
17.2.5 G4X - 33KV (NOMINAL UNIT WT- 0.52 MT) =4 Sets MT 2.08
17.3 TOTAL WEIGHT OF COLUMN & BEAM MT 68.60 0.00 0.00 0.00 0.00
SWITCH YARD EQUIPMENT STRUCTURES (LATTICE TYPE) FOR 132/33
17.4
KV CLASS INCLUDING FOUNDATION BOLTS & NUTS.
17.4.1 Structure for 132KV CT (Unit Weight - 214.546 Kg) =15 Nos MT 3.22
17.4.2 Structure for 132KV IVTs (Unit Weight - 231.195 Kg) =9 Nos MT 2.08
17.4.3 Structure for 132KV Surge Arrester (Unit Weight - 179.893 Kg) =12 Nos MT 2.16
17.4.4 132 KV Single Isolator without Earth Switch (Unit weight - 658.767 Kg) = 9 Nos MT 5.93
17.4.5 132 KV Double Isolator without Earth Switch (Unit Weight - 979.10 Kg) = 2 Nos MT 1.96
17.4.6 132 KV Double Isolator with Earth Switch (Unit Weight - 1120.559 Kg) = 2 Nos MT 2.24
17.4.7 Structure for 132KV BPI (Unit Weight - 309.883 Kg) =18 Nos MT 5.58
17.4.8 Structure for 33KV CT (Unit Weight - 148.80 Kg) =18 Nos MT 2.68
17.4.9 Structure for 33KV IVTS (Unit Weight - 124.336 Kg) =3 Nos MT 0.37
17.4.10 Structure for 33KV LAs (Unit Weight - 148.8 Kg) =6 Nos MT 0.89
17.4.11 33 KV Single Isolator without Earth Switch (Unit weight - 294.893 Kg) = 18 Nos MT 5.31
17.4.12 33 KV Single Isolator with Earth Switch(Unit weight - 324.8 Kg) = 5 Nos MT 1.62
17.4.13 Structure for 33KV BPI (Unit Weight - 148.80 Kg) =22 Nos MT 3.27
17.4.14 Structure for 33KV HG Fuse (Unit Weight - 245 Kg) =2 Nos MT 0.49
17.4.12 TOTAL WEIGHT OF EQUIPMENT STRUCTURE MT 37.80 0.00 0.00 0.00 0.00
Total weight of GI Nuts and bolts for the above Column, Beam &
17.5 equipment structures and including different size of plain washer / MT 5.32 0.00 0.00 0.00 0.00
spring washer for above structures.
Laying of Power and Control Cable including fixing of cable with terminal
connections both at equipments and control panels with supply and fixing of
lugs, Ferrules, clamps, connectors, glands, fixing of cable trays/ laying in ground
in HDPE pipes, including supply of N & B, Link plates, Cable Markers, PVC pipes
18 Bends, Plaster of Paris, M-Seal compounds etc for sealing purpose and all
necessary arrangements, laying of Earthing Flats, earthing, laying of Cable trench
slabs and chequered plate etc for the cable trench, Cable scheduled and cable
diagram to be prepared by the contractor
18.1 POWER CABLES, 1.1KV, XLPE / PVC FRLS ARMOURED, ALUMINIUM
CONDUCTOR (As per Specification)
18.1.1 XLPE 3.5 CX300 mm2 Mtrs 300 0.00 0.00 0.00 0.00
18.1.2 XLPE 3.5 CX185 mm2 Mtrs 300 0.00 0.00 0.00 0.00
18.1.3 XLPE 3.5 CX120 mm2 Mtrs 200 0.00 0.00 0.00 0.00
18.1.4 PVC 3.5 CX70 mm2 Mtrs 200 0.00 0.00 0.00 0.00
18.1.5 PVC 3.5 CX35 mm2 Mtrs 1800 0.00 0.00 0.00 0.00
18.1.6 PVC 4 CX 16 mm2 Mtrs 700 0.00 0.00 0.00 0.00
18.1.7 PVC 4 CX 6 mm2 Mtrs 1500 0.00 0.00 0.00 0.00
18.1.8 PVC 2CX 6 mm2 Mtrs 2000 0.00 0.00 0.00 0.00
18.2 CONTROL CABLES, 1.1 KV, PVC ARMOURED, STRANDED COPPER FRLS
(As per specification)
18.2.1 2 CX 2.5 mm2 Mtrs 1500 0.00 0.00 0.00 0.00
18.2.2 4 CX 2.5 mm2 Mtrs 12000 0.00 0.00 0.00 0.00
18.2.3 5 CX 2.5 mm2 Mtrs 1500 0.00 0.00 0.00 0.00
18.2.4 7CX 2.5 mm2 Mtrs 4500 0.00 0.00 0.00 0.00
18.2.5 10 CX 2.5 mm2 Mtrs 4000 0.00 0.00 0.00 0.00
18.2.6 12 CX 2.5 mm2 Mtrs 3500 0.00 0.00 0.00 0.00
18.2.7 16 CX 2.5 mm2 Mtrs 500 0.00 0.00 0.00 0.00
18.2.8 19 CX 2.5 mm2 Mtrs 1500 0.00 0.00 0.00 0.00
SINGLE CORE 1.1KV, PVC UN-ARMOURED COPPER CONDUCTOR: for
18.3 connection from Battery Set to Battery Charger and from Battery Charger to
DCDB on cable tray / HDPE pipe/PVC pipe etc
18.3.1 1CX 120 mm2 BAT TO BAT CHARGER & CHARGER TO DCDB Mtrs 200 0.00 0.00 0.00 0.00
132/33 KV, 20 MVA Transformer: Receiving the Transformers and its
accessories & dragging and Installing on the plinth and placing in position,
Erection of accessories of the Transformers, erection of NCTs on the
Transformers, Earthing as per Standard (Including Supply of Materials), Vacuum
Treatment of the tank and winding, Oil Filtration (Including Supply of Vacuum
cum Oil Filter Machine), Supply & Laying of all types of Control & Power Cables
19 Pertaining to Transformers, Testing and Commissioning including all tests of the Nos 2 0.00 0.00 0.00 0.00
Oil as per stipulation in the Standard Approved Testing Laboratory and as per the
instruction of the Engineer in Charge. This include all related works for Erection,
Testing and Commissioning of the Power Transformers/Auto Transformers.
(Contractor to arrange Power Supply for Filtration And Vacuum Treatment works).
It also includes supply of all materials required for erection Including T & P's.
20.2 Aux BCU for station auxiliary system (Station AC, station DC, Lighting, Firefighting, DG set, Air
conditioning etc): as per requirement compliant to IEC 61850 - ED-2 protocol with PRP on FO. Nos 1 0.00 0.00 0.00 0.00
Power Supply 220V DC.
20.3 GPS System with IRIG-B/SNTP/PTP with VDU (Clock)
Nos 1 0.00 0.00 0.00 0.00
20.4 132KV Level Protection Panel- Single Panel Twin Bay Type (2 Bays in One Panel) with
IEC 61850-ED-2 PRP on FO
20.4.1 132KV feeder Protection Panel: Feeder-1 & 2 in one panel
Numerical Distance protection relay, BCPU and other auxiliary relays as per requirement Nos 1 0.00 0.00 0.00 0.00
compliant to IEC 61850-ED-2 protocol with PRP on FO. Power Supply 220V DC.
20.4.2 132KV Transformer Protection Panel: Transformer-1 & 2 in one panel
Numerical Differential protection relay, BCPU and other auxiliary relays as per requirement Nos 1 0.00 0.00 0.00 0.00
compliant to IEC 61850-ED-2 protocol with PRP on FO. Power Supply 220V DC.
20.4.3 132KV Buscoupler Protection Panel: BCPU and other auxiliary relays as per requirement compliant
to IEC 61850-ED-2 protocol with PRP on FO. Power Supply 220V DC.
Nos 1 0.00 0.00 0.00 0.00
20.5 33KV Level Protection Panel- Single Panel Twin Bay Type (2 Bays in One Panel) with
IEC 61850-ED-2 PRP on FO
20.5.1 33KV Feeder Protection Panel: with BCPU & with other Auxiliary relays as required as per the
scheme compliant to IEC 61850 - ED-2 protocol with PRP on FO. Power Supply 220V DC.
33KV Buscoupler Protection Panel: with BCPU & with other Auxiliary relays as required as per the
scheme compliant to IEC 61850-ED-2 protocol with PRP on FO. Power Supply 220V DC. Nos 3 0.00 0.00 0.00 0.00
Note: 5 Nos. of Line Feeder Bays and 1 Bus coupler to be considered in 3 Panels.
20.5.2 33KV Transformer protection panel: with BCPU, numerical REF & with other Auxiliary relays as
required as per the scheme, compliant to IEC 61850-ED-2 protocol with PRP on FO. Power Supply
220V DC. Nos 1 0.00 0.00 0.00 0.00
21.1 AC SYSTEM
21.1.1 MAIN AC DB ( Indoor Type): MAIN DB-1, MAIN DB-2 with B/C. The incomer &
Bus coupler shall have 800 A, 50KA, drawout type with Numerical SAS compliant
Relay (O/C, E/F, U/V, O/V protection).The ACDB shall be suitable for automatic Set 1 0.00 0.00 0.00 0.00
switching OFF & ON during power failure. Facilities for integration with SAS as per
the site requirement.
21.1.2 ACDB (Indoor Type): AC DB-1, AC DB-2 with B/C. Incomer-1 & 2, Bus coupler
and DG set Incomer-1 & 2 shall have 400A Motorised MCCB for automatic
operation. The ACDB shall be suitable for automatic switching OFF & ON , auto Set 1 0.00 0.00 0.00 0.00
start of DG set etc during power failure. Facilities for integration with SAS as per
the site requirement.
21.1.3 Main Lighting Distribution Board (Indoor Type): Having 250A MCCB for Incomers
Set 1 0.00 0.00 0.00 0.00
with source-1, Source-2 & Bus coupler.
21.1.4 Indoor Lighting Distribution Board (Indoor Type) Set 1 0.00 0.00 0.00 0.00
21.1.5
Emergency Lighting Distribution Board (Outdoor type): The ELDB should be
Set 1 0.00 0.00 0.00 0.00
supplying to 20% of switchyard lights, each of 132KV and 33KV Switchyard.
21.1.6 Indoor Receptacle Board Set 1 0.00 0.00 0.00 0.00
21.1.7 Bay Marshalling Kiosk (Outdoor type): 1 BMK for 3 nos 132KV bays and 1 BMK for
Nos 5 0.00 0.00 0.00 0.00
4 nos 33KV bays
21.1.8 Console Box for Switchyard Lighting (Outdoor type) Nos 2 0.00 0.00 0.00 0.00
21.1.9 Console Box for Street Lighting (Outdoor type) Nos 2 0.00 0.00 0.00 0.00
21.1.10 Console Box for Colony Supply (Outdoor type) Nos 1 0.00 0.00 0.00 0.00
21.1.11
Switchyard Receptacle Board for Transformer Oil Filtration (Outdoor type) Nos 1 0.00 0.00 0.00 0.00
21.1.12
Switchyard Receptacle Board for Welding & Other Emergency (Outdoor type) Nos 2 0.00 0.00 0.00 0.00
21.1.13
CT Out Door Console Boxes ( 132 KV CT-5 Nos, 33 KV CT-8 Nos) (Outdoor type) Nos 13 0.00 0.00 0.00 0.00
21.1.14
PT Out Door Console Boxes (132 KV IVT-3 No., 33 KV IVT-1 No.) (Outdoor type) Nos 4 0.00 0.00 0.00 0.00
21.1.15 Outdoor kiosk for Station Transformer (Outdoor type) Nos 2 0.00 0.00 0.00 0.00
21.1.16 ACDB for Yard Kiosk (Indoor Type): LT supply to Protection panels, Kiosk
Nos 1 0.00 0.00 0.00 0.00
lighting, AC etc made of 2mm CR sheet
21.1.17
DCDB for Yard Kiosk (Indoor Type): DC supply to Protection panels having source-
Nos 1 0.00 0.00 0.00 0.00
1 & 2 with auto changeover facility, made of 2mm CR sheet.
21.2 DC SYSTEM:
21.2.1 220 V DC DISTRIBUTION BOARD (Indoor Type): Having 63A DC MCCB for
Incomers, Bus Coupler with interlock, E/F (EARTH LEAKAGE), UNDER & OVER Set 1 0.00 0.00 0.00 0.00
VOLTAGE and shall be SAS compliant.
21.2.2 220 V DC Emergency Lighting Distribution Board (Indoor Type) Set 1 0.00 0.00 0.00 0.00
21.2.3
Battery cells (2.2V), 350 AH Plante Type for 220 V DC (107 Nos + 3 Nos spare) Nos -2 0.00 0.00 0.00 0.00
21.2.4 Battery Charger For 350 Ah Plante Type Battery, 107 cells, 2.2V, Trickle charge
volt-2.25V(Float & Float Cum Boost). The Charger ON/OFF status, input/output
Set 1 0.00 0.00 0.00 0.00
voltage, output current, associated charger protection signals shall be provided
for integration with SAS.
22 ACCESSORIES FOR OPGW SYSTEM With OPGW cable
22.1 24 Fibre Optic Approach cable along with HDPE Pipes km 1.00 0.00 0.00 0.00 0.00
22.2 Optical line Terminal Equipment(OLTE) -STM4 type SDH equipment with
integrated MUX & tributary cards for speech & data ports for interfacing of
Nos 1.00 0.00 0.00 0.00 0.00
Speech & data which should be compatible with existing OPTCL system including
all accessories for successful commissioning.
22.3 Supply of FODP(Fibre Optic Distribution Panel)48 F: Indoor type,rack mounted
Nos 1.00 0.00 0.00 0.00 0.00
with FCPC coupling and pig tails(DWSm Fibre)
22.4 48 V, 300 AH, maintenance free VRLA Battery set. Set 1.00 0.00 0.00 0.00 0.00
22.5 SMPS based battery charger of 75A suitable for 48V VRLA battery. Nos 1.00 0.00 0.00 0.00 0.00
22.6 48V DCDB Nos 1.00 0.00 0.00 0.00 0.00
22.7 Earth Flat, Cable Tray, Foundation rail, Junction Box,. Lot 1.00 0.00 0.00 0.00 0.00
SUB STATION LIGHTING (AS PER SPECIFICATION AND APPROVED
DRAWINGS )(Switch yard and other street area): Design, engineering,
procurement of labour, material including all associated works for construction of
switch yard lightings as per technical specification and approved drawings. The
Light fixture shall be of reputed make (Philips / CGL / Bajaj / Havells / Crompton)
23 and fixtures shall be LED type and proper cabling from the lighting outdoor
distribution boards to the junction boxes and from junction boxes to the fixtures.
The lighting fixtures are to be installed on the switch yard structures & Street
Light Poles. The quantity of such fixtures are to be designed and to be
ascertained through the Lighting Design Calculation for acceptable Lux levels.
Air Conditioners
AIR CONDIONER: Installation of 2T capacity Split Air Conditioning Units (Dual
Inverter, five star or better type, latest model) with copper condensor having
remote temperature & operation control facility.
Installation of AC Control Panel made of 2mm CR sheet, having suitable outgoing
(one outgoing for one AC & with overload control gear) & wiring materials with
15 amp socket & plug for each unit of AC etc to complete (As per specification)
21 Set 12 0.00 0.00 0.00 0.00
for Control/SAS Room, ACDC Room Communication room, office room &
Conference room .
The ACs in the ACDC Room(04 nos) shall run in tandem i.e 2 ACs at a time for 4
hours each. Suitable control arrangement shall be made using 24hr timer for start
and stop. Similarly, for Control Room (2 ACs) and Communication Room (2ACs),
one AC at a time for 4 hours each. One AC each in office rooms(2 nos),
Conference Room, for
Air conditioners Transit
YardRoom.
AC Kiosk with successful commissioning of the
Set 2 0.00 0.00 0.00 0.00
units as per TS.
Placement of Supplied Fire Exitinguishers at various locations of the
22
substations as per instruction of Site Engineer.
22.1 FOAM TYPE-9 LTRS Nos 4 0.00 0.00 0.00 0.00
22.2 DRY CHEMICAL POWDER(TROLLEY MOUNTED)- 25 KGS Nos 4 0.00 0.00 0.00 0.00
22.3 DRY POWDER TYPE -6 KGS Nos 4 0.00 0.00 0.00 0.00
22.4 CO2 - 4.5 KGS Nos 10 0.00 0.00 0.00 0.00
22.5 CO2 - 9.0 KGS Nos 10 0.00 0.00 0.00 0.00
22.6 CO2 (TROLLY MOUNTED)- 22.5 KGS Nos 4 0.00 0.00 0.00 0.00
22.7 Water type- 9 LTRS Nos 4 0.00 0.00 0.00 0.00
22.8 Foam type - 50 LTR Nos 4 0.00 0.00 0.00 0.00
FIRE BUCKET (6 Nos IN EACH STAND) WITH STAND With Canopy arrangement
22.9 Set 6 0.00 0.00 0.00 0.00
Maintenance Testing Equipment (All equipment shall comply to the TS 1
23 0.00 0.00 0.00 0.00
and as per list below) Lot
Demonstration of the 100KV Automatic Transformer Oil Breakdown Voltage test Nos 1
23.1
set (Megger- OTS 100AF / Baur- DTA 100C)
Demonstration of the 10KV Insulation Tester with 15m test lids (Megger- S1-1068 Nos 1
23.2
/ Sonel-MIC 10K1)
Demonstration of the Digital Earth Tester (Facility with soil resistivity Nos 1
23.3
measurement) (Megger-DET2/3 / Sonel MRU-120 / Fluke 1625)
23.4 Demonstration of the Digital Multimeter (Megger / Fluke) Nos 2
23.4.1 Demonstration of the Digital Clamp meter (Megger/Fluke/Motwane) Nos 1
Demonstration of the Leakage current clamp meterAC & DC both (30mA / 300mA Nos 1
23.4.2
/ 30A / 300A) (Megger/Fluke/Kyoritsu)
23.4.3 Demonstration of the SF6 Gas Leakage Detector (Kika/DILO) Nos 1
Demonstraion of the Fibre Glass Discharge / Earth Rod: Grip up to 50mm, Min Set 6
23.5.1 height-16ft, rubber grip, 35 sq.mm copper cable (1 set- 3 cables, 1 set of rod,
carry bag) (Bemico)
24 Demonstraion of the Portable High Beam Light (rechargeable) Nos 2
Installation of the Desktop Computer: (HP/Lenovo/Dell) complete with all Set 2
25 accessories including webcam and speakers and validation of the Genuine
Windows Operating System
Installation of the UPS 600VA (APC/V Guard) and verification of the backup Nos 2
25.1.8
Installation of the Laser Printer, Black & White, Duplex printing (print, scan & Nos 1
25.1.9
copy) (HP/Canon/Epson)
Installation and demonstration of De Mineralised Plant. The capacity/Hr of the
26 palnt and the sp gravity of the de-mineralised water shall be verified and certified Set 1 0.00 0.00 0.00 0.00
by the site engineer.
Installation & demo of the 20 Ltr Storage Water Cooler (Voltas/Bluestar only) for 1
27 0.00 0.00 0.00 0.00
performance
Installation and demo of the Water Purifier (Kent/Aquaguard/ for performance 1
28 0.00 0.00 0.00 0.00
Office Furniture: Godrej make (As per details below). Placing In Control Room, Communication Lot 1
29 0.00 0.00 0.00 0.00
Room, Conference Room, Office Rooms, Library, Testing Lab etc.
For Control Room, conference room, office rooms, Library, testing room etc
29.1
29.2 5ftX3ft executive table with drawer both sides Nos 4
29.3 4.5ft X 2.5ft Table with one side drawer Nos 7
Computer table suitable keeping monitor, CPU, UPS and printer with two nos 1
29.4 Set
revolving arm chair suitable for computer use.
29.5 Executive revolving, adjustable (height) chairs with arm Nos 4
29.6 Cushion fixed “S” type steel chairs with arm Nos 16
29.7 6ftX3ft conference table Nos 1
29.8 Cushion arm steel chairs for conference table purpose. Nos 6
6ft height steel almirah (only with selves) for keeping records and other valuable 3
29.9 Nos
items.
29.10 6ft height steel almirah with glass doors for library purpose Nos 2
6ft height (having minimum 6 lockers facility) steel cupboard with locking 2
29.11 Nos
arrangement.
4ft steel rack (minimum three selves) for keeping the files and other items. 8
29.12 Nos
Weight of different type G.I Nuts & Bolts and including different size of
1.7 MT 2.5662 0.00 0.00 0.00 0.00
plain washer / spring washer for tower structure
1.8 Fixing of of Templates & Setting of stubs.
1.8.1 PA (Nominal unit weight- 0.492 MT)(1 nos.) MT 0.492
1.8.2 PB (Nominal unit weight- 0.624 MT)(1 no.) MT 0.624
1.8.3 PC (Nominal unit weight- 0.876 MT)(1 no.) MT 0.876
1.8.4 UR (Nominal unit weight-1.476 MT)(0 nos) MT 0.000
1.8.5 OC (Nominal unit Weight- 1.006 MT)(0 Nos) MT 0.000
1.9 Total of Template erection MT 1.992 0.00 0.00 0.00 0.00
Erection of the following tower accessories as per technical
2.0 specification and as directed by the engineer in charge.
NOTE
1 Before filling up rate/amount etc. in the schedules bidders are requested to read carefully the instruction given in Vol-I of Bidding Document.
2 Bidders are required to fill up only blue shaded cells.
Bidders are requested to not leave any column blank. If any column is left blank it shall be considered that amount against those items are included in any other item and the total amount for that item shall be calculated as free of
3 cost (Zero value).
4 Basic Price (taxable value) for supply includes Packing & Forwarding, freight & insurance etc. excluding GST with full Input Tax Credit)
ODISHA POWER TRANSMISSION CORPORATION LIMITED
PACKAGE -CPC-55/2022-23 NAME OF THE WORK:-
132/33 KV S/S AT JHARBANDH & ASSOCIATED 132 KV LILO NOTICE INVITING TENDER-NIT NO. -CPC-55/2022-23 & BID DOCUMENT No.:Sr. G.M- CPC- e-Tender-
LINE PRICE BID FOR WORKS CONTRACT (SAC CODE - 995423): SCHEDULE - VII-C - PART -III CIVIL WORKS
COMPONENT OF THE WORKS CONTRACT-( PACKAGE- 55/2022-23)
(CIVIL WORKS)
NAME OF
BIDDER
CIVIL WORKS _SUBSTATION
DESCRIPTION OF ITEMS(SCHEDULE-VIIC-SS) UNIT OF BASIC PRICE CGST @ 9% OGST @ 9% TOTAL PRICE TOTAL PRICE FOR
QUANTITY:
CIVIL WORK COMPONENT OF THE WORKS CONTRACT OF FOLLOWING MEASURE PER UNIT PER UNIT PER UNIT PER UNIT ( In THE QUANTITY
Sl. No. EQUIPMENTS (As per Technical Specification) MENT (Taxable Value) (INTRA-STATE) (INTRA- Rs)
In Rs STATE)
(2) Design, Engineering, Providing and laying of plain cement concrete (PCC
1:3:6) of grade M10 with approved quality coarse aggregates (Nominal size
12mm to 20mm) , fine aggregates, cement in cable trench as blind layer
inclusive of labour charges for concrete mixing & curing. This includes supply of
all labourers, T&P and dewatering wherever required as per Technical
specification and instruction of Engineer In charge.
(3) Open cast foundation for the cable trench with RCC: 1:1.5:3 (Grade M-20
Nominal mixing), including supply of Labour all materials like MS Rod, Cement,
coarse and fine aggregates, shuttering, cutting, bending, binding of M.S.Rod
including supply of binding wire proper curing of the foundations/concrete and
T&P in line with the Specification and as per direction of Engineer in Charge.
(4) Fly ash Brickwork with fly ash Brick, plastering (1:6 Ratio) & curing, wherever
required including the supply of labour, material, cement, etc.
(5) The outdoor cable trench wall top surface shall be "L" shaped and
the cover slabs shall be placed with in the"L shaped" surface of both
the walls. The top surface of the trench shall be smooth finished.
(6)Supply,fabrication & Fixing of GI Angle for cable tray support (as per
specification). The cable tray support frame shall be pre fabricated GI angle as
per requirement and to be welded with the GI insert plate fixed on the trench wall
for better rigidity. The Insert plate (6mm) fixed on the wall are also to be welded
with the MS rods provided for the trench wall before concreting.
(7) Precast of RCC covers (1:1.5:3) with MS sheet(2mm) frame and its
fixing on the cable trench as per spec and instruction of Engg. In Charge.
(8) All the RCC cover slabs shall have the lifting hooks. The slabs
without the MS sheet frame and Lifting hooks shall not be accepted.
(8) Cable Trenches Inside The Control Room Shall Be Covered With M.S
Chequered Plate(Duly Painted As Per Instruction Of Engg In Charge) Including
Standard Support Stand {Hd Galvanised (M.S Joist , Channel, Angle). Stoppers
shall be fixed at the underneath so that the chequered shall not be falling into the
cable trench in any case.
5.2 Section 3-3 Mtrs 50 0.00 0.00 0.00 0.00
Section 4-4
(inside dimensions- width- 400mm, height- 400mm), wall- 75mm,
5.3 Mtrs 50 0.00 0.00 0.00 0.00
bottom concrete-75mm, two 150mm trays shall be laid side by side in
one layer.
Rain water harvesting system as per Technical specification and approval of
6 Nos 2 0.00 0.00 0.00 0.00
drawing and as per the direction of the Engineer in charge.
Cable trench crossing:Design,engineering,construction including supply of
labour,materials,cement,reinforcement steel,formwork etc,and all associated
7
works for construction of trench crossing as per technical specification and
approved drawing.(Road crossing )
7.1 Section 3-3 Nos 1 0.00 0.00 0.00 0.00
Switchyard AC Kiosk:
Yard AC Kiosk made of RCC structure and Brick walls with complete finishing as
per instruction of Engineer In Charge:
The dimension of the Yard Kiosk shall be such as to accommodate all the 132&
33KV protection relay panels, RTCC panels, ACDB, DCDB, Metering panel and
space for two nos 132KV & 2 nos 33KV future bay panels.
1. The Kiosk finished Floor shall be 300mm above the FGL of switchyard.
8 2. The Kiosk shall have floor cutouts in the form of cable trench for installation of Nos 2 0.00 0.00 0.00 0.00
SAS Panels.
3. The inside cable trench shall be routed to the switchyard through pipes.
4. Wall cutout shall be provided for installation of the Air conditioner system.
5. Two nos of doors shall be provided.
Work shall be carried out as per OPTCL approved drawing and on instruction of
Engineer in Charge.
4 Back filling available excavated earth (excluding rock) in trenches, plinth, sides of Cum 109.69 0.00 0.00 0.00 0.00
foundations etc. in layers not exceeding 20 cm in depth, consolidating each
deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
4 Carriage / disposal of excavated surplus earth from the worksite by mechanical Cum 438.77 0.00 0.00 0.00 0.00
means within a lead of 5Km including loading and unloading etc. complete. in all
respect as per direction of Engineer-in-Charge.
5 Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers Cum 543.37 0.00 0.00 0.00 0.00
including watering and ramming with cost, conveyance, royalties and taxes of
sand with labour and T&P required for the work etc. complete (Measurement will
be taken on finished compacted section only).
6 Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation and Cum 86.34 0.00 0.00 0.00 0.00
floors using 4cm (1 1/2") 0 mm & down grade black hard crusher broken granite
stone metal, washed and screened sharp sand of approved quality from approved
quarry including hoisting, lowering, laying the concrete, ramming, watering and
curing etc. complete to required thickness including cost of all materials,
conveyance, loading, unloading,cost of labours, T&P, hire & running charges of
concrete mixer, etc. all complete as per the direction of the Engineer -in -charge.
7 Providing & laying Plain cement concrete (1:2:4) using 12mm size black hard
crusher broken granite chips of approved quality from approved quarry including
hoisting, lowering and laying concrete in layers, watering, curing etc. complete
including cost, conveyance, royalties and taxes of all materials with labour, cess
and T&P etc. required for the work complete.
A GROUND FLOOR
a Foundation & bases of column cum 142.73 0.00 0.00 0.00 0.00
b Plinth Beam cum 16.23 0.00 0.00 0.00 0.00
c Pedestal & Columns cum 30.41 0.00 0.00 0.00 0.00
d Roof Beam cum 22.24 0.00 0.00 0.00 0.00
e Lintel cum 2.74 0.00 0.00 0.00 0.00
f Chajja sqm 25.32 0.00 0.00 0.00 0.00
g R.C.C. floor and roof slab cum 54.37 0.00 0.00 0.00 0.00
h R.C.C. staircase cum 3.09 0.00 0.00 0.00 0.00
B FIRST FLOOR & HEAD ROOM
a Columns cum 19.09 0.00 0.00 0.00 0.00
b Roof Beam cum 21.89 0.00 0.00 0.00 0.00
c Lintel cum 3.36 0.00 0.00 0.00 0.00
d Chajja sqm 16.10 0.00 0.00 0.00 0.00
e R.C.C. floor and roof slabs cum 47.64 0.00 0.00 0.00 0.00
f R.C.C. staircase cum 3.27 0.00 0.00 0.00 0.00
9 Cutting, straightening coiled or bent up M.S. rods, HYSD steel or Tor Steel
welding or jointing if necessary, bending, binding, tying the grills as required for
RCC works, and hoisting, lowering and placing in proper position according to
approved designs and drawings including cost, conveyance, loading, unloading,
M.S. rods, HYSD steel or Tor steel and binding wires of 18 to 20 gauge required
for the work and cost of all labour, sundries, T&P and scaffolding complete in all
respect as directed by the Engineer-in-Charge (payment will be made according
to the actual weight of M.S. rod, HYSD steel or Tor steel consumed in the work
and no separate payment will be made towards weight of binding wires which is
to be borne by the contractor at his own cost).
A GROUND FLOOR Qntl 336.87 0.00 0.00 0.00 0.00
B FIRST FLOOR Qntl 131.06 0.00 0.00 0.00 0.00
10 Fly Ash brick masonry using fly ash bricks of size 25 cm. x 12 cm. x 8 cm. having
crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6)
with ordinary portland cement (OPC) and screened & washed sand for mortar
after immersing the bricks for 6 (Six) hours in water before use including splays
cutting, circular moulding, corbelling, chamfering and similar such type of works,
watering and curing etc. including cost, conveyance, loading, unloading, royalties
of all materials, cost of all labour, scaffolding, sundries, T&P required for the
works etc. complete in all respect as directed by the Engineer-in-charge
A Foundation & Plinth Cum 47.26 0.00 0.00 0.00 0.00
B GROUND FLOOR Cum 97.83 0.00 0.00 0.00 0.00
C FIRST FLOOR & HEAD ROOM Cum 67.06 0.00 0.00 0.00 0.00
11 Fly Ash brick masonry using fly ash bricks of size 25 cm. x 12 cm. x 8 cm. having
crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:4)
with ordinary portland cement (OPC) and screened & washed sand for mortar
after immersing the bricks for 6 (Six) hours in water before use in Superstructure
including splays cutting, circular moulding, corbelling, chamfering and similar such
type of works, watering and curing etc. including cost, conveyance, loading,
unloading, royaltiesof all materials, cost of all labour, scaffolding, sundries, T&P
required for the works etc. complete in all respect as directed by the Engineer-in-
charge
A GROUND FLOOR cum 2.13 0.00 0.00 0.00 0.00
B FIRST FLOOR HEAD ROOM cum 5.33 0.00 0.00 0.00 0.00
12 Providing 16 mm. thick cement plaster (1:6) finished smooth to inside brick walls
after racking out the joints including watering and curing with cost, conveyance,
loading, unloading, royalties of all materials, cost of all labour, T&P, sundries and
scaffolding required for the work etc. with providing grooves as directed by the
Engineer in charge.
A GROUND FLOOR Sqm 809.76 0.00 0.00 0.00 0.00
B FIRST FLOOR Sqm 672.45 0.00 0.00 0.00 0.00
13 Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces
such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams
and lofts etc. including roughening/chipping, scraping and cleaning and finishing
the plastered surface smooth using wooden floats, bars, etc. only to proper
plumbs and level, making grooves, beads and drip coarse to give required
ornamental finish as per drawing including cost of all materials, conveyance,
loading and unloading, royalties, cost of all labour, scaffolding, staging, watering
before plastering and curing, sundries and T&P, etc. complete as per direction of
the Engineer-in-charge.
A FIRST FLOOR & HEAD ROOM Sqm 304.34 0.00 0.00 0.00 0.00
36 Providing & applying of pre constructional anti-termite treatment by drilling 12mm Sqm 224.23 0.00 0.00 0.00 0.00
dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep
enough to reach the soil below & chemical emulsion (PREMISE, IMIDACHLOPRIED
30.5SC OF BAYER MAKE mixed with 47.5ltr water) pumped these holes to soak
the soil @ 1 ltr solution of each hole as per manufactures specification & the holes
should be pluged the filling materials including cost of all materials,
labour,conveyance, T&P , all taxes and hire charges of machinaries as per
direction of Engineer-in-charge.
37 Providing and fixing of UPVC sliding windows 2 track sliding-60 series/Top hung
ventilator of any approved make ,duly manufactured using upvc reinforced
profiles of 62mm x 60mm x 2.25mm for outer frame, 66mm x 38mm x 2.25mm
for sliding shutter frames capable of mounting single glazing system,structurally
reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.2
mm prefabricated and welded through fusion welding & the window sash shall be
fitted with 5 mm thick clear float glass of reputed make duly fixed with EPDM
weathering seal including the cost of all materials,necessary locking arrangements
,fittings,cost of labour,T&P ,etc complete as per direction of Engineer-in-charge.
Access Floor panel shall be steel welded construction with an enclosed bottom
pan with uniform pattern of 64 hemispherical cones.The access floor shall be
factory finished with Anti-static High Pressure laminate with Non Warp technology
upto 1 mm thickness for superior adhesion and Surface flatness within 0.75 mm.
The panel into withstand a Concentrated Load of 363 kgs applied on area 25 mm
x 25 mm without collapse in the centre of the panel which is placed on four steel
blocks.The panel will withstand and Uniformly Distributed Load (UDL) minimum
1250 kg/sqm and an impact load of 50 kg all complete as per the approved
manufacturers specification and as per the direction of Engineer-in-charge
8 Providing 12 mm. thick cement plaster in all floors at all height with cement SQM 157.50 0.00 0.00 0.00 0.00
mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside
rough surface of brick masonry walls after racking out joints including watering
and curing rounding of corners etc. complete with cost, coveyance, loading and
unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries
and scaffolding required for the work etc. with providing grooves as directed by
the Engineer in charge.
TOTAL - COVERED DRAIN (B.3) 0.00
B.4 P H WORKS
1 Providing, Supplying & Fixing of Rimless, Blind Installation wall Hung WC of CERA EACH 6.00 0.00 0.00 0.00 0.00
(CAT NO S1059102and Cistern-B1510121), (Size :520x360x390mm) with PP soft
close slim seat cover (Cat. No. B1510121 Cajol seat cover), Hinges, Accessories
with all fittings & fixtures complete including making good the damages .
including cost of all materials, labour, T&P, lead, royality etc.complete in all
respects as per direction of Architect /Engineer in charge.
2 Providing, Supplying & Fixing of Toilet roll Holder with Stainless steel flap of CERA EACH 6.00 0.00 0.00 0.00 0.00
(CAT- F5001109) with all fittings & fixtures complete including making good the
damages . including cost of all materials, labour, T&P, lead, royality etc.complete
in all respects as per direction of Architect /Engineer in charge.
3 Providing, Supplying & Fixing of Hand Shower (Health Faucet) with 8mm dia, each 6.00 0.00 0.00 0.00 0.00
1.2m long flexible tube and wall hook of CERA (F8030103)with all fittings &
fixtures complete including making good the damages . including cost of all
materials, labour, T&P, lead, royality etc.complete in all respects as per direction
of Architect /Engineer in charge.
4 Providing, Supplying & Fixing of Stop cock, male end with wall flange of each 6.00 0.00 0.00 0.00 0.00
CERA(F1018201) will all fittings & fixtures complete including making good the
damages including cost of all materials, labour, T&P, lead, royality etc. complete
in all respects as per direction of Architec/Engineer in charge.
5 Providing, Supplying & Fixing of 2 Way Bib cock with wall flange of CERA each 6.00 0.00 0.00 0.00 0.00
(F1018163) with all fittings & fixtures complete including making good the
damages. including cost of all mateials, labour, T&P, lead, royality etc. complete
in all respects as per direction of Engineer in charge.
6 Providing, Supplying & Fixing Basin of CERA of size 515x410x195 mm (CAT-NO. EACH 8.00 0.00 0.00 0.00 0.00
S2040120) with full pedestal height 850MM (CAT NO. S2090113 ) with all fitings
& fixtures complete including cost of all materials, labour, T&P, lead, royality etc.
complete in all respects as per direction of Engineer in charge
7 Providing, Supplyin & Fixing of Basin inlet connection (angle valve) of CERA EACH 8.00 0.00 0.00 0.00 0.00
(F1018201) with all fittings & fixtures complete including cost of all materials,
labour, T&P, lead, royality etc. complete in all respects as per direction of
Engineer in charge.
8 Providing, Supplying & Fixing Glass Shelf 300X300mm long of CERA (F5005103) EACH 8.00 0.00 0.00 0.00 0.00
with all fittings & fixtures complete including making good the damages. including
cost of all materials, labour, T&P, lead, royality etc. complete in all respects as per
direction of Engineer in charge.
10 Providing, Supplying & Fixing pillar cock with aerator with long screws, shanks each 8.00 0.00 0.00 0.00 0.00
and back nuts of CERA (CAT-F2007101) with all fittings & fixtures complete
including making good the damages. including cost of all materials, labour, T&P,
lead, royality etc. complete in all respects as per direction of Engineer in charge.
11 Providing, Supplying & Fixing standard sized Single Towel rail of 600mm long, each 6.00 0.00 0.00 0.00 0.00
stainless steel complete with Chromiun Plated brass brackets of CERA (F5003103)
with all fittings & fixtures complete including making good the damages. including
cost of all materials, labour, T&P, lead, royality etc. complete in all rescpects as
per direction of Engineer in charge.
12 Providing, Supplying & Fixing standard sized Chromium Plated brass towel EACH 8.00 0.00 0.00 0.00 0.00
ring(round) of CERA (F5003105) with all fittings & fixtures complete including
making good the damages. including cost of all materials, labour, T&P, lead,
royalitity etc. complete in all respects as per direction of Engineer in charge.
13 Providing, Supplying & Fixing Soap dish holder of CERA (F5007105) with all EACH 14.00 0.00 0.00 0.00 0.00
fittings & fixtures complete including making good the damages. including cost of
all materials, labour, T&P, lead, royality etc. complete in all respects as per
direction of Engineer in charge.
14 Providing, Supplying & Fixing Towel Shelf 600mm long with lower hangers, EACH 6.00 0.00 0.00 0.00 0.00
stainless steel complete with Chromiun Plated brass brackets ofCERA (F5007101)
with all fittings & fixtures completer including making good the damages.
including cost of all materials, labour, T&P, lead, royality etc. complete in all
respects as per direction of Engineer in charge.
15 Providing, Supplying & Fixing of Bib cock short body (with straight line model) each 6.00 0.00 0.00 0.00 0.00
with wall flange polished bright ofCERA (F2013151) with all fittings & fixtures
completer including making good the damages. including cost of all materials,
labour, T&P, lead, royality etc. complete in all respects as per direction of
Engineer in charge.
16 Providing, Supplying & Fixing of Long body Bib cock with wall flange polished each 6.00 0.00 0.00 0.00 0.00
bright of CERA (CAT-SQT-512KN) with all fittings & fixtures completer including
making good the damages. including cost of all materials, labour, T&P, lead,
royality etc. complete in all respects as per direction of Engineer in charge.
17 Providing, Supplying & Fixing Overhead shower 70mm Round shape single flow each 6.00 0.00 0.00 0.00 0.00
(ABS Body Chorme plated with Gray face plate) with Rubit cleaning system (EOS-
542A) and Shower arm 235mm long (Light weight) round shape for wall mounted
showers with wall flange (ALE-536A) of CERAwith all fittings & fixtures completer
including making good the damages. including cost of all materials, labour, T&P,
lead, royality etc. complete in all respects as per direction of Engineer in charge.
18 Providing, Supplying & Fixing of Concealed Stop cock, Heavy Body with Cap of each 6.00 0.00 0.00 0.00 0.00
CERA (F1018201) with all fittings & fixtures completer including making good the
damages. including cost of all materials, labour, T&P, lead, royality etc. complete
in all respects as per direction of Engineer in charge.
19 Providing, Supplying & Fixing Double Coat hook ofCERA (F5003108) with all each 6.00 0.00 0.00 0.00 0.00
fittings & fixtures completer including making good the damages. including cost of
all materials, labour, T&P, lead, royality etc. complete in all respects as per
direction of Engineer in charge.
20 Providing, Supplying & Fixing 600mm x 300mm bevelled edge mirror of superior EACH 8.00 0.00 0.00 0.00 0.00
glass mounted on 5mm thick A.C sheet or plywood sheet with all fittings &
fixtures completer including making good the damages. including cost of all
materials, labour, T&P, lead, royality etc. complete in all respects as per direction
of Engineer in charge.
21 Providing & Fixing of PVC nahani trap with 125mm stainless steel grating with/ EACH 12.00 0.00 0.00 0.00 0.00
without hole for waste pipe in floors / at any location cost includes all materials,
labour, tools,plant etc. complete in all respects.as per price list of ASTRAL
22 Fixing bowl pattern urinal conforming to IS 2556 : Part 6-1996 including EACH 6.00 0.00 0.00 0.00 0.00
connecting the urinal of 330x310x420 mm size with waste pipe by means of
white lead mixed with chopped hemp etc all complete as per specification. (CERA
MAKE, CAT-F5001109)
23 Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste
ventilating pipes (type-A / ring fit type ) with all PVC fittings of
ASTRAL/AJAY/SUPREME make as per IS 13592 to walls with nails, bobbins and
laying in trenches including all pipe fittings, jointing materials, tools plant, labour
& all material, earthwork in excavation in all kinds of soil and refilling of trenches
as per specification and direction of the engineer in charge.
24 160mm dia PVC (SWR) pipe class "A" ( with wall thickness of 3.2mm to 3.8mm) MTR 50.00 0.00 0.00 0.00 0.00
25 110 mm dia PVC (SWR) pipe Class „A‟ (with wall thick of 2.20 mm to 2.70 mm) MTR 50.00 0.00 0.00 0.00 0.00
26 75 mm dia PVC (SWR) pipe Class „A‟ (with wall thick of 1.8 mm to 2.20 mm ) MTR 50.00 0.00 0.00 0.00 0.00
27 Providing all materials, labour and T&P for fixing of Upvc SWR fittings
a 75 x 75 x 75mm single Tee with door Each 10.00 0.00 0.00 0.00 0.00
b 110 x 110 x 110 mm single Tee with door Each 10.00 0.00 0.00 0.00 0.00
c 75 x 75 x 75mm single Tee without door Each 5.00 0.00 0.00 0.00 0.00
d 110 x 110 x 110 mm single Tee without door Each 5.00 0.00 0.00 0.00 0.00
e 160 x 160x 110 mm Reducing Tee with door Each 10.00 0.00 0.00 0.00 0.00
f 110 x 110 x 75 mm Reducing Tee with door Each 10.00 0.00 0.00 0.00 0.00
g 75 mm x 87.50 Plane Bend Each 40.00 0.00 0.00 0.00 0.00
h 110 mm x 87.50 Plane Bend Each 40.00 0.00 0.00 0.00 0.00
i 75mm coupler Each 40.00 0.00 0.00 0.00 0.00
j 110mm coupler Each 50.00 0.00 0.00 0.00 0.00
k 75 mm vent cowl with SS Jali Each 20.00 0.00 0.00 0.00 0.00
l 110 mm vent cowl with SS Jali Each 20.00 0.00 0.00 0.00 0.00
m 75mm pipe clip Each 50.00 0.00 0.00 0.00 0.00
n 110mm pipe clip Each 50.00 0.00 0.00 0.00 0.00
o 160mm pipe clip Each 50.00 0.00 0.00 0.00 0.00
p 110 mm x 75 mm Nahani Trap without Jali Each 12.00 0.00 0.00 0.00 0.00
q 110 mm Square Gully Trap Each 6.00 0.00 0.00 0.00 0.00
r 125 x 110mm WC Connector Each 8.00 0.00 0.00 0.00 0.00
s 110mm WC Connector (Bend) Each 8.00 0.00 0.00 0.00 0.00
t 110mm WC Connector (Straight) Each 8.00 0.00 0.00 0.00 0.00
28 Providing and laying in trench cement concrete ( 1:4:8 ) with 40mm size hard MTR 150.00 0.00 0.00 0.00 0.00
granite metal in the following type of bedding for 150mm diameter including
curing complete as per specification
29 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of (
ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal
stability for hot & cold water supply SDR 11 , including all CPVC plain & brass
threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step CPVC solvent cement and
testing of joints complete as per direction of Engineer in Charge.
Internal work
V GROUND FLOOR
a 15 mm nominal outer dia Pipes MTR 25.00 0.00 0.00 0.00 0.00
b 20 mm nominal outer dia Pipes MTR 25.00 0.00 0.00 0.00 0.00
c 25 mm nominal outer dia Pipes MTR 20.00 0.00 0.00 0.00 0.00
VI FIRST FLOOR
a 15 mm nominal outer dia Pipes MTR 25.00 0.00 0.00 0.00 0.00
b 20 mm nominal outer dia Pipes MTR 25.00 0.00 0.00 0.00 0.00
c 25 mm nominal outer dia Pipes MTR 20.00 0.00 0.00 0.00 0.00
30 Providing all materials, labour, T&P for laying/fixing to wall or ceiling and floor
uPVC solvent weld pipe Sch-80 as per ASTM-D-1785 and pipe fittings of following
nominal bore with clamps including making good the wall, ceiling & floor all
complete as per specification.
External work
V GROUND FLOOR
a 40 mm nominal outer dia Pipes MTR 20.00 0.00 0.00 0.00 0.00
VI FIRST FLOOR
a 40 mm nominal outer dia Pipes MTR 10.00 0.00 0.00 0.00 0.00
b 50 mm nominal outer dia Pipes MTR 150.00 0.00 0.00 0.00 0.00
31 Cutting grooves in pucca floors and walls for taking GI/PVC /CPVC pipes including MTR 200.00 0.00 0.00 0.00 0.00
making good the damages caused with cost of all material,labour, scafolding,
tools, plant, royalty etc. complete in all respects.
32 Supplying all materials, jointing materials, labour and T&P and fixing of uPVC
pressure fittings (Sch-80) as per ASTM-D 2467 (Make: ASTRAL)
a 20 mm EACH 10.00 0.00 0.00 0.00 0.00
b 25 mm EACH 10.00 0.00 0.00 0.00 0.00
c 32 mm EACH 10.00 0.00 0.00 0.00 0.00
d 40 mm EACH 10.00 0.00 0.00 0.00 0.00
e 50 mm EACH 10.00 0.00 0.00 0.00 0.00
33 Supplying all materials,labours,T&P and cutting holes through existing brickwork EACH 150.00 0.00 0.00 0.00 0.00
including making good the damages in cement mortar (1:4) for taking GI /CPVC
/PVC pipes and fittings etc all complete as per PH specification and direction of
Engineer-in-charge.
34 Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene NO 1.00 0.00 0.00 0.00 0.00
cylindrical vertical water storage tanks conforming to IS : 12701--1996 including
cutting holes through the tank and fixing mild steel tubes and fittings and
providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto
a height of 5 metres above ground level and placing the tank to the required
position and providing 1st class Fly ash brickwork in cement mortar (1:6) of
0.46m height in staging and in circular protection wall to support the tank, 12mm
thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and
0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement
concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,
watering, curing, conveyance of all materials to worksite etc all complete as per
specification and direction of the Engineer in charge. Fixing 2000Ltr Roto-moulded
water storage tank (Syntax Make) In first Floor
5 Providing & laying Plain Cement concrete (PCC ) of proportion (1:3:6) in CUM 4.32 0.00 0.00 0.00 0.00
foundation and floors using 4cm (1½”) size clean hard black crusher broken
granite stone metal of approved quality and from approved quarry including
hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to
the required level ramming, watering, curing etc. complete including cost,
conveyance, royalties and taxes of all materials with all labour, cess and T&P
required for the work etc. complete in all respect.
6 Cutting, straightening coiled or bent up M.S. rods, HYSD steel or Tor Steel CUM 2.88 0.00 0.00 0.00 0.00
welding or jointing if necessary, bending, binding, tying the grills as required for
RCC works, and hoisting, lowering and placing in proper position according to
approved designs and drawings including cost, conveyance, loading, unloading,
M.S. rods, HYSD steel or Tor steel and binding wires of 18 to 20 gauge required
for the work and cost of all labour, sundries, T&P and scaffolding complete in all
respect as directed by the Engineer-in-Charge (payment will be made according
to the actual weight of M.S. rod, HYSD steel or Tor steel consumed in the work
and no separate payment will be made towards weight of binding wires which is
to be borne by the contractor at his own cost).
7 Providing strong, rigid, leveled, and plumbed centering and shuttering to required
shape and size , for floors with ply or steel centering materials with all necessary
bracing and tiles and supports with leveling centering covered with plastic sheet
with provisions necessary holes and pockets for electrical conduits, pipes, P.H.
pipes, for hooks or boxes, switch and board insert plates, clamps and extension
bars etc., including dismantling the same after the required interval from the date
of casting including cost of all materials, labour, conveyance, loading and
unloading, taxes, royalties, scaffolding, watering, curing, sundries, tools and
plants, etc., complete as per the direction of the Engineer-in-charge.
A R.C.C. floor and roof slabs, landings, balconies, projecting sun shades and chajjas SQM 28.80 0.00 0.00 0.00 0.00
upto 4.3m height
8 Reinforcement for RCC work including straightening, cutting, bending, placing in QNTL 2.88 0.00 0.00 0.00 0.00
position and binding all complete. lifting and placing in position as per design
complete including cost of bars , binding wires , including cost of all materials,
labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and
plants, etc. complete as per the direction of the Engineer-in-charge. (linear
measurement will be taken and quantity will be calculated on standard weight for
all heights)-Thermo Mechanically Treated bars
9 Providing Brick work with Fly ash bricks 25cm x 12m x 8cm size having crushing
strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in
cement mortar ( 1 cement: 6 sand), with all necessary projection, splay cutting,
circular moulding, corbelling, etc., including cost of all materials, labour,
conveyance, loading ,and unloadining, taxes, royalties, scaffolding, watering,
curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-
charge.
Foundation & Plinth CUM 25.99 0.00 0.00 0.00 0.00
10 Providing 16 mm. thick cement plaster in all floors at all height with cement SQM 107.58 0.00 0.00 0.00 0.00
mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside
rough surface of brick masonry walls after racking out joints including watering
and curing rounding of corners etc. complete with cost, coveyance, loading and
unloading, royalties and taxes of all materials and cost of all labour, T&P, sundries
and scaffolding required for the work etc. with providing grooves as directed by
the Engineer in charge.
11 Providing neat cement punning over plastered/ concrete surface including SQM 107.58 0.00 0.00 0.00 0.00
watering and curing complete with cost, coveyance, loading and unloading,
royalties and taxes of all materials and cost of all labour, T&P, sundries and
scaffolding required for the work etc. as directed by the Engineer in charge.
12 Providing 6 mm. thick cement plaster in all floors at all height with cement mortar SQM 28.80 0.00 0.00 0.00 0.00
of mix (1:4) with portland slag cement (PSC) finished smooth to inside rough
surface of brick masonry walls after racking out joints including watering and
curing rounding of corners etc. complete with cost, coveyance, loading and
unloading, royalties and taxes of all materials and cost of all labour, T&P, sundries
and scaffolding required for the work etc. with providing grooves as directed by
the Engineer in charge.
13 Supplying & Fixing of Manhole cover ( heavy duty ) 450mm x 450mm water tight NO 2.00 0.00 0.00 0.00 0.00
type including frame cost includes all material,labour, tax,lead tools & plant etc.
complete
14 Supplying all materials,labours,T&P and constructing 1.22m dia and NO 1.00 0.00 0.00 0.00 0.00
2.1m depth soakway pit with precast RCC rings joined loose,gravel
backing in the rear of well steining,precast RCC cover slab in cement
concrete (1:2:4) using 12mm size hg chips fitted with iron lifting
handles including cutting hole in the rings for inlet pipe,earthwork in
open well excavation in all kinds of soil and refilling of cavity around
the pit & painting the iron works, watering, curing, conveyance of all
materials to worksite, payment of royalty, taxes etc all complete as per
approved specification and direction of Engineer-in-charge
TOTAL-SEPTIC TANK & SOAK PIT (B.5) 0.00
B.6 BORE WELL
1 Conducting VES Test for locating feasible site for drilling of bore well with
minimum yield of 1.75 LPS and above (Minimum 3 VES Test are to be conducted
for one location) including 20% failed VES Tests and as per direction of the
Engineer-in-charge
2 Labour for drilling a perfectly vertical bore
hole of specified dia for a specified depth
below ground level through consolidated and unconsolidated rock with down the
hole hammer rig or combination drilling rig as required to suit the site condition
as per
direction of the Engineer-in-charge including use of own/hired/leased rigs with its
accessories, tools, plants and consumables etc. for lowering of 200mm dia PVC
Pipes for housing with or without screen as per the necessity for soft, medium,
hard and boulder formation (suitable casing pipe, if required to prevent collapse
of over burden is to be
provided by the service provider including
lowering and withdrawing after completion of the bore well). 200 mm dia to
400mm dia in over burden portion including packing of gravel where ever
necessary & as per direction of the Engineer-in-charge.
A Cost of drilling to accommodate 200mm dia
pipe lowering 0 to 30 mtrs and above. T=30
Mtr.
B Drilling of minimum 150mm dia bore hole in hard rock up to 100 Mtr. & above.
T=49 Mtr.
C Lowering the casing pipe of 200mm dia
with or without slotted pipes as per the
necessity from ground level up to 30 meters & above depth and fitted and fixed
up in perfectly vertical position, including cutting, threading and slotted pipe and
supply and fixing all jointing materials, tools and plants etc. complete and keeping
the top of the casing pipe threaded including plugging the bore well to prevent
entry of foreign materials from above 0 to 30 meter and above. T=30 Mtr.
D Cost of 200mm dia PVC C.S. Class Pipe of
reputed make with IS 12818/2010 specification. Manufacturer name should
prominently be marked with CIPET test certification in the body of the pipe in
indelible ink or stencilled to the satisfaction of Engineer-in-charge.T-30 Mtr.
3 cleaning and developing the tube well using their own compressor continuously
worked till clear and adequate discharge is obtained from the well including
supply and use of all necessary equipment and labour as per the direction of the
Engineer-in-charge
4 Conducting yield test through pumping for
minimum 6-8 hours including supply of suitable Submersible pump set having
capacity of discharge of 3.50 LPS at 100 Mtr. head with 15KVA D.G. Set and a
container of 200 ltrs. Capacity as required to suit the site condition as per the
direction of the Engineer-in-charge including supply of tools plants labourers for
lowering and lifting the pump set and measuring the yield of the bore well
8 Supplying and fixing compression type gland complete with brass gland insulated
cable ends by soldering with cable sockets and insulated tapes etc.
9 Supplying, fitting and fixing 50mm dia full way valve (heavy quality) ISI marked.
10 Supplying, fitting and fixing M.S. clamp to hold 50mm dia G.I. pipe and
submersible pump set.
Rate for Item No. 1 to Item No. 10 SET 1.00 0.00 0.00 0.00 0.00
11 Supplying and fixing complete in operational conditions, including necessary NO 1.00 0.00 0.00 0.00 0.00
jointing and coupling centifugal pump self priming type with automatic on/off
(make- Crompton Greaves/ KSB/Kirloskar) and motor of specified complete with
50mm x 50mm suction and delivery, motor starter (star/delta) and suitable for
lifting water to a height of 25 Mtr approx ( vertical head) complete with
connections and accessories etc. complete with a guarantee of one year. (1 H.P.
capacity.)
12 Supplying & fixing G.I. Pipes (TATA medium tube) 50mm dia for connection the MTR 80.00 0.00 0.00 0.00 0.00
suction to the pump & from delivery to the overhead tank with all necessary G.I.
fittings such as bends,U , tees, elbows, reducers, sockets, caps, clamps,
plugs,union etc. & making good the damages as per drawing including cost of all
materials, labour,T&P etc.complete in all respects as per direction of Engineer.
( c) GROUP C: Wiring for light point/ fan point/ exhaust fan point/ call bell point with Nos. 60 0.00 0.00 0.00 0.00
1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /
recessed medium class PVC conduit, with modular switch, modular plate, suitable
GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable etc. as required. (((Make
:Legrand(Myrius)/MK(elements)/Pansonic(Europa)/Hager(Insysta)
(b) Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call Nos. 30 0.00 0.00 0.00 0.00
bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated
copper conductor single core cable in surface/ recessed PVC conduit, and earthing
the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable
etc. as required. (((Make
:Legrand(Myrius)/MK(elements)/Pansonic(Europa)/Hager(Insysta)
(d) Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated Nos. 20 0.00 0.00 0.00 0.00
single core multistrand copper conductor of ISI marked in recess 20 mm dia non-
metalic PVC flexible conduit with modular type switch ,4 module 18SWG modular
GI box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core
multistrand copper conductor for loop earthing etc. as required. ( Make of wire
Finolex / Anchor / Havels / V Guard/KEl )
(e) Supplying and fixing of 4module GI box with cover on surface or in recess with Nos. 15 0.00 0.00 0.00 0.00
suitable size of phenolic laminated sheet cover in front including providing and
fixing 5 pin 15 / 16 amps socket outlet and 15 / 16 amps modular type switch,
connection, painting etc as required.(Make-Anchor/crabtree/Legrand)
1.2 Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated Nos. 30 0.00 0.00 0.00 0.00
single core multistrand copper conductor of ISI marked in recess 20 mm dia non-
metalic PVC flexible conduit with modular type switch ,6 module 18SWG modular
GI box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core
multistrand copper conductor for loop earthing etc. as required. ( Make of wire
Finolex / Anchor / Havels /KEI )
1.3 Supply and fixing of 20 amp 240 V SPN industrial type socket outlet with 2 pole NO 18 0.00 0.00 0.00 0.00
and earth metal encloser plug top along with 20 amp "C" series SP MCB in sheet
steel enclosure on surface or in recess with chained metal cover for the socket
outlet and complete connections, testing and commissionig etc. as required.(Make-
Legrand (Mylink)/Siemens/Hager)
1.4 Supplying and fixing of 100W,step type regulator, 2 Module without base and Nos. 36 0.00 0.00 0.00 0.00
cover including connection etc as required.(Make
:Legrand(Myrius)/MK(elements)/schneider(Zencelo)
1.5 Supplying and fixing modular blanking plate on the existing modular plate & Nos. 10 0.00 0.00 0.00 0.00
switch box excluding modular plate as required.
1.6 Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe Mtrs. 100 0.00 0.00 0.00 0.00
and making good the damages caused complete as required and as per Direction
of Engineer-In-Charge. (Make :Legrand(Myrius)/MK(elements)/schneider(Zencelo)
1.7 Supplying and fixing T.V. antenna socket outlet piano type ISI marked on the NO 2 0.00 0.00 0.00 0.00
existing switchboard / cover including connections etc as requird.
1.8 Supply, delivery and laying of following sizes of 2 mm Wall thickness rigid PVC
Conduit Concealed in Wall/ Column/ Roof Slab of the Building or mounted on
surface along with other accessories and 18 SWG GI Fish Wire complete for
Telephone / TV / Computer / Circuit or Sub main wiring as required & as per
Direction of Engineer-In-Charge.
(a) 20 mm dia. Mtrs. 50 0.00 0.00 0.00 0.00
(b) 25 mm dia. Mtrs. 60 0.00 0.00 0.00 0.00
1.9 Supplying, delivery, installation, testing and commissioning of Flush mounted Cat Nos. 15 0.00 0.00 0.00 0.00
6 Information DUAL Outlet Box.on GI concealed Modular Switch Board including
connections and making good the damages caused complete as required & as per
Direction of Engineer-In-Charge.
2 Supplying, laying of UTP 4 PAIR Cat 6 lane 2 run cable Wire in the existing Mtrs. 400 0.00 0.00 0.00 0.00
surace/recessed PVC Pipe as required.
2.1 Supplying, delivery, installation, testing and commissioning of 9U SERVER rack Nos. 2 0.00 0.00 0.00 0.00
with PDU 6 SOCKET 2 nos ventilating IN-out ans and cable manager including
connections and making good the damages caused complete as required & as per
Direction of Engineer-In-Charge.
2.2 Supplying, delivery, installation, testing and commissioning of 24 port Nos. 2 0.00 0.00 0.00 0.00
10/100/1000 Mbps managed switch with 4 gigabit sfp slots as per direction of
E.I.C
2.3 Supplying, delivery, installation, testing and commissioning of 24 port Cats 6 utp Nos. 2 0.00 0.00 0.00 0.00
patch panel with cable manager as per direction of E.I.C
2.4 Supplying, delivery, installation, testing and commissioning of 24 port Cats 6 utp Nos. 20 0.00 0.00 0.00 0.00
Factory crimped patch cord 1m as per direction of E.I.C
2.5 Supplying, delivery, installation, testing and commissioning of 24 port Cats 6 utp Nos. 20 0.00 0.00 0.00 0.00
Factory crimped patch cord 2m as per direction of E.I.C
2 Wiring for Circuits and Submain with following number & sizes of PVC insulated
1100 Volt Grade Multistranded Copper Conductor FRLS Wire run inside 2 mm
thick PVC Conduit Pipe Recessed in Ceiling / Column / Walls of Building including
supply of all materials such as wires, PVC Conduit, Junction Box & Pull Box etc.
complete with making good the damages caused as required and as per
Direction of Engineer-In-Charge. (Make of wire Finolex/Anchor/Havels/KEI)
(a) 2 Nos. Single Core 1.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Mtrs. 200 0.00 0.00 0.00 0.00
Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD (Make of wire Anchor/Havels/KEI)
(b) 2 Nos. Single Core 2.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Mtrs. 220 0.00 0.00 0.00 0.00
Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD (from LDB to Room & Power Point and Common Light Point looped).(Make of
wire Anchor/Havels/KEI)
(c) 2 Nos. Single Core 4.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Mtrs. 150 0.00 0.00 0.00 0.00
Single Core 2.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD.(Make of wire Anchor/Havels/KEI)
(d) 2 Nos. Single Core 10.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Mtrs. 110 0.00 0.00 0.00 0.00
Single Core 4 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD.(Make of wire Anchor/Havels/KEI)
(e) 4 Nos. Single Core 16.0 mm2 FRLS Copper Wire for Phase and Neutral and 2 No. Mtrs. 80 0.00 0.00 0.00 0.00
Single Core 10 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD.(Make of wire Anchor/Havels/KEI)
3 BRANCH DISTRIBUTION BOARDS:
3.1 Supplying and fixing following way, Three pole and neutral, sheet steel, MCB Nos. 2 0.00 0.00 0.00 0.00
distribution board, 415 V, on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, TPN
DB Double door Make:LEGRAND(DX3)/SIEMENS(Betagaurd)/Schneider(Acti 9)/GE
3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB Nos. 2 0.00 0.00 0.00 0.00
distribution board, 240V, on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way,
SPN DB Double door Make:LEGRAND(DX3)/SIEMENS(Betagaurd)/Schneider(Acti
9)/GE
3.3 Supplying and fixing following rating, 63 amp 4pole MCB , (Three phase and Nos. 2 0.00 0.00 0.00 0.00
neutral), 415 V having a sensitivity current 10 KA in the existing MCB DB
complete with connections, testing and commissioning etc. as required.
3.4 Supplying and fixing following rating, double pole, 40 amp RCCB(single phase Nos. 2 0.00 0.00 0.00 0.00
and neutral), 240 V, residual current circuit breaker (RCCB),
having a sensitivity current 300 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Make:LEGRAND(DX3)/SIEMENS(Betagaurd)/Schneider(Acti 9)/GE
3.3 Supplying and fixing Single pole 5 amps to 32 amps rating, 240/415 volts, "C" Nos. 40 0.00 0.00 0.00 0.00
curve, miniature circuit breaker suitable for inductive load of following poles in the
existing MCB DB complete with connections, testing and commissioning etc. as
required.
3.6 Supplying and fixing single pole blanking plate in the existing MCB DB complete Nos. 6 0.00 0.00 0.00 0.00
etc. as required.
5 FITTINGS & FIXTURES:
5.1 Supply,Installation and testing of following types of LED Tube Fixtures Directly on
Wall / Ceiling/ Structure of Building with all accessories such as Electronics
Ballast, Lamps, Stove Enameled Box, Perplex Sheet Cover etc. complete assembly
With supply of required T&P and making connection from the suitable point outlet
as per the Direction of Engineer-In-Charge. Make- PHILIPS, ,LT,WIPRO,TRILUX,
PAC,HALONIX/Eq make
(A) Supply of Surface mounted indoor type 20 WATT LED Inverter LED Batten with Nos. 32 0.00 0.00 0.00 0.00
Opal Diffuser, IP20, Battery back-up & Functioning as per Product TDS complete
assembly With supply of required T&P and making connection from the suitable
point outlet as per the Direction of Engineer-In-Charge(Make-Halonix Cat No LED
INVERTER BATTEN HLB-08-20-CW-INV/WIPRO/CROMPTON/LT/PHILIPS
(B) Supply of 18 watt Surface mounted indoor type Round LED Luminaire with Nos. 19 0.00 0.00 0.00 0.00
LED GLARE FREE opal diffuser ,IP20 Lamp complete assembly With supply of
required T&P and making connection from the suitable point outlet as per the
Direction of Engineer-In-Charge.
C) Supply of 10 WATT LED BOLLARD LIGHT complete 5700K assembly With supply NOS 4 0.00 0.00 0.00 0.00
of required T&P and making connection from the suitable point outlet as per the
Direction of Engineer-In-Charge
D) Supply 36 W LED PREMISES LIGHT 6500 CCT complete assembly With supply Nos. 6 0.00 0.00 0.00 0.00
of required T&P and making connection from the suitable point outlet as per the
Direction of Engineer-In-Charge
E) Supply of 10 W Inverter LED Bulb in B-22 cap and with Opal Diffuser, IP20, Nos. 8 0.00 0.00 0.00 0.00
Battery back-up & Functioning as per Product TDS Luminaire with LED complete
assembly With supply of required T&P and making connection from the suitable
point outlet as per the Direction of Engineer-In-Charge(Make-Make-HALONIX Cat
No 10W B22 CW IP/PHILIPS/WIPRO/CROMPTON
F) Supply delivery, installation, testing & commissioning of following types of Nos. 25 0.00 0.00 0.00 0.00
recessed/Surface mounted 36 watt indoor type LED panel 2' x 2' square LED
Luminare with 120 Lm/w with high efficency made 6500 cct IP40 LED chip life
of 50,000 burning hours at L70 - Minimum tested for 10K hours for complaince of
TM21 projection. Luminaire driver should be Isolated and multistage constant
current APFC type. Driver should be BIS registered with Input voltage range of
90V to 265V ( nominal rated voltage – 240V) with minimum 2 KV surge
protection, PF >0.90, THD <10%; IP 40; and as per the direction of E.I.C;.
Make:WIPRO / LT / TRILUX/REGENT/HALONIX/OSRAM
5.2 Installation, testing and commissioning of pre-wired, LED fitting / compact LED Nos 92 0.00 0.00 0.00 0.00
fitting of all types, complete with all accessories and tube/lamp etc. directly on
ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and earthing etc. as required.
5.3 Numbering of ceiling fan/ exhaust fan/ light fittings as required. Nos. 138 0.00 0.00 0.00 0.00
6 Supply, delivery, installation and testing of following Sweeps of High Speed Nos. 36 0.00 0.00 0.00 0.00
Energy Efficient A.C 1200 mm 48 '' Sweep Ceiling Fan 210 CMM Air Delivery..
GOOD BYE Anti Dust Super striker Ceiling Fan complete with Fan Blades, Down
Rod, Canopies & Capacitor etc. including supply of Sundry Materials, making
connection from the suitable point outlet but excluding cost of Fan Regulator
complete as required and as per the Direction of Engineer-In-Charge.(Make-
USHA , Halonix,Bajaj)
6.1 Supply, delivery, installation & testing of following Sweep & Speed 230 mm Nos. 8 0.00 0.00 0.00 0.00
EXHAUST FAN 1400 RPM. on Existing Sheet Metal Switch Board including loop
connections and making good the damages caused complete as required and as
per direction of Engineer-in-charge(Make-USHA , Halonix, ,Bajaj )
2 Supply, installation, testing and commissioning of stylish low profile designed Nos 15 0.00 0.00 0.00 0.00
conventional Photo electric smoke detector Make-Siemens/ Honeywell
/Bosch/GST/equivalent make as per direction of Engineer-in-charge.
3 Supply, installation, testing and commissioning of analogue soft addressing Nos 2 0.00 0.00 0.00 0.00
resettable PVC body Manual call point with integral short circuit isolator etc as
reqd. Make-Siemens/ Honeywell /Bosch/GST/equivalent make as per direction
of Engineer-in-charge.
4 Supply, installation, testing and commissioning of soft addressed wall mounting / Nos 2 0.00 0.00 0.00 0.00
ceiling mounting sensor based sounder low profile designed The sounder uttilises
high intensity LEDS to provided highly visiable red coloured flash light with sound
to alert (Up to 100 DB) occupancies for evacution during fire etc as reqd. Make-
Siemens/ Honeywell /Bosch/GST/equivalent make as per direction of Engineer-in-
charge.
5 Supplying and drawing followings sizes of PVC insulated copper conductor 2 core Mtr 150 0.00 0.00 0.00 0.00
1.5 sqmm flexible cable in the existing surface / recessed steel conduit etc as
reqd.Make-Polycab/Havells/equivalent make as per direction of Engineer-in-
charge.
Sub TOTAL-CONTROL ROOM BUILDING FIRE ALARM SYSTEM (B.8) 0.00
3 Back filling available excavated earth (excluding rock) in trenches, plinth, sides of Cum 9.3 0.00 0.00 0.00 0.00
foundations etc. in layers not exceeding 20 cm in depth, consolidating each
deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
4 Carriage / disposal of excavated surplus earth from the worksite by mechanical Cum 37.21 0.00 0.00 0.00 0.00
means within a lead of 5Km including loading and unloading etc. complete. in all
respect as per direction of Engineer-in-Charge.
5 Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers Cum 39.32 0.00 0.00 0.00 0.00
including watering and ramming with cost, conveyance, royalties and taxes of
sand with labour and T&P required for the work etc. complete (Measurement will
be taken on finished compacted section only).
6 Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation and Cum 6.56 0.00 0.00 0.00 0.00
floors using 4cm (1 1/2") 0 mm & down grade black hard crusher broken granite
stone metal, washed and screened sharp sand of approved quality from approved
quarry including hoisting, lowering, laying the concrete, ramming, watering and
curing etc. complete to required thickness including cost of all materials,
conveyance, loading, unloading,cost of labours, T&P, hire & running charges of
concrete mixer, etc. all complete as per the direction of the Engineer -in -charge.
7 Providing and laying in position ready mixed M-25 grade concrete having
compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced
cement concrete work, using cement content as per approved design mix,
manufactured in fully automatic batching plant and transported to site of work in
transit mixer for all leads, having continuous agitated mixer, manufactured as per
mix design of specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying , including the cost of
centering, shuttering finishing and excluding reinforcement including cost of
admixtures in recommended proportions as per IS : 9103 to accelerate/ retard
setting of concrete, and hoisting, lowering, laying and compacting concrete,
watering and curing and finishing the exposed surfaces smooth with cost,
conveyance, royalties, of all materials with all labour,Labour cess and T&P
required for the work improve workability without impairing strength and
durability as per direction of the Engineer - in - charge.
A GROUND FLOOR
a Foundation & bases of column cum 8.82 0.00 0.00 0.00 0.00
b Plinth Beam cum 3.63 0.00 0.00 0.00 0.00
c Pedestal & Columns cum 5.71 0.00 0.00 0.00 0.00
d Roof Beam cum 1.97 0.00 0.00 0.00 0.00
e Lintel cum 0.78 0.00 0.00 0.00 0.00
g R.C.C. floor and roof slab cum 2.23 0.00 0.00 0.00 0.00
B FIRST FLOOR
a Columns cum 4.20 0.00 0.00 0.00 0.00
b Roof Beam cum 11.94 0.00 0.00 0.00 0.00
e R.C.C. floor and roof slabs cum 5.46 0.00 0.00 0.00 0.00
8 Cutting, straightening coiled or bent up M.S. rods, HYSD steel or Tor Steel
welding or jointing if necessary, bending, binding, tying the grills as required for
RCC works, and hoisting, lowering and placing in proper position according to
approved designs and drawings including cost, conveyance, loading, unloading,
M.S. rods, HYSD steel or Tor steel and binding wires of 18 to 20 gauge required
for the work and cost of all labour, sundries, T&P and scaffolding complete in all
respect as directed by the Engineer-in-Charge (payment will be made according
to the actual weight of M.S. rod, HYSD steel or Tor steel consumed in the work
and no separate payment will be made towards weight of binding wires which is
to be borne by the contractor at his own cost).
A GROUND FLOOR Qntl 30.32 0.00 0.00 0.00 0.00
B FIRST FLOOR Qntl 33.55 0.00 0.00 0.00 0.00
9 Fly Ash brick masonry using fly ash bricks of size 25 cm. x 12 cm. x 8 cm. having
crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6)
with ordinary portland cement (OPC) and screened & washed sand for mortar
after immersing the bricks for 6 (Six) hours in water before use including splays
cutting, circular moulding, corbelling, chamfering and similar such type of works,
watering and curing etc. including cost, conveyance, loading, unloading, royalties
of all materials, cost of all labour, scaffolding, sundries, T&P required for the
works etc. complete in all respect as directed by the Engineer-in-charge
A Foundation & Plinth Cum 8.22 0.00 0.00 0.00 0.00
B GROUND FLOOR Cum 9.81 0.00 0.00 0.00 0.00
C FIRST FLOOR Cum 3.19 0.00 0.00 0.00 0.00
10 Providing 16 mm. thick cement plaster (1:6) finished smooth to inside brick walls
after racking out the joints including watering and curing with cost, conveyance,
loading, unloading, royalties of all materials, cost of all labour, T&P, sundries and
scaffolding required for the work etc. with providing grooves as directed by the
Engineer in charge.
A GROUND FLOOR Sqm 61.49 0.00 0.00 0.00 0.00
B FIRST FLOOR Sqm 16.58 0.00 0.00 0.00 0.00
11 Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces
such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams
and lofts etc. including roughening/chipping, scraping and cleaning and finishing
the plastered surface smooth using wooden floats, bars, etc. only to proper
plumbs and level, making grooves, beads and drip coarse to give required
ornamental finish as per drawing including cost of all materials, conveyance,
loading and unloading, royalties, cost of all labour, scaffolding, staging, watering
before plastering and curing, sundries and T&P, etc. complete as per direction of
the Engineer-in-charge.
B GROUP B: Wiring for light point/ fan point/ exhaust fan point/ call bell point with Nos. 2 0.00 0.00 0.00 0.00
1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /
recessed medium class PVC conduit, with modular switch, modular plate, suitable
GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable etc. as required. ((Make
:Legrand(Myrius)/MK(elements)/Pansonic(Europa)/Hager(Insysta)/Eq make
C GROUP C: Wiring for light point/ fan point/ exhaust fan point/ call bell point with Nos. 4 0.00 0.00 0.00 0.00
1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /
recessed medium class PVC conduit, with modular switch, modular plate, suitable
GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable etc. as required. ((Make
:Legrand(Myrius)/MK(elements)/Pansonic(Europa)/Hager(Insysta)/Eq make
(b) Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call Nos. 5 0.00 0.00 0.00 0.00
bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated
copper conductor single core cable in surface/ recessed PVC conduit, and earthing
the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable
etc. as required. ((Make
:Legrand(Myrius)/MK(elements)/Pansonic(Europa)/Hager(Insysta)/Eq make
(c) Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated Nos. 2 0.00 0.00 0.00 0.00
single core multistrand copper conductor of ISI marked in recess 20 mm dia non-
metalic PVC flexible conduit with modular type switch ,4 module 18SWG modular
GI box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core
multistrand copper conductor for loop earthing etc. as required. ( Make of wire
Finolex / Anchor / Havels / V Guard/KEl )
(D) Supplying and fixing of 4module GI box with cover on surface or in recess with Nos. 2 0.00 0.00 0.00 0.00
suitable size of phenolic laminated sheet cover in front including providing and
fixing 5 pin 15 / 16 amps socket outlet and 15 / 16 amps modular type switch,
connection, painting etc as required.(Make-Anchor/crabtree/Legrand)
1.2 Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated Nos. 2 0.00 0.00 0.00 0.00
single core multistrand copper conductor of ISI marked in recess 20 mm dia non-
metalic PVC flexible conduit with modular type switch ,6 module 18SWG modular
GI box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core
multistrand copper conductor for loop earthing etc. as required. ( Make of wire
Finolex / Anchor / Havels /KEI )
1.3 Supply and fixing of 20 amp 240 V SPN industrial type socket outlet with 2 pole NO 1 0.00 0.00 0.00 0.00
and earth metal encloser plug top along with 20 amp "C" series SP MCB in sheet
steel enclosure on surface or in recess with chained metal cover for the socket
outlet and complete connections, testing and commissionig etc. as required.(Make-
Legrand (Mylink)/Siemens/Hager)
1.4 Supplying and fixing of 100W,step type regulator, 2 Module without base and Nos. 1 0.00 0.00 0.00 0.00
cover including connection etc as required.(Make
:Legrand(Myrius)/MK(elements)/schneider(Zencelo)
1.5 Supplying and fixing modular blanking plate on the existing modular plate & Nos. 2 0.00 0.00 0.00 0.00
switch box excluding modular plate as required.
1.6 Wiring to Telephone Socket Outlet from Junction Box with 0.5 mm2 Twin Pair Mtrs. 60 0.00 0.00 0.00 0.00
Copper Conductor Telephone Wire run inside prelaid PVC Conduit complete
including termination, testing etc complete as required and as per Direction of
Engineer-In-Charge. (Make :Legrand(Myrius)/MK(elements)/schneider(Zencelo)
1.7 Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe Mtrs. 50 0.00 0.00 0.00 0.00
and making good the damages caused complete as required and as per Direction
of Engineer-In-Charge. (Make :Legrand(Myrius)/MK(elements)/schneider(Zencelo)
1.8 Supplying and fixing of RJ11 telephone jack single with shutter & RJ 45 computer NO 1 0.00 0.00 0.00 0.00
jack with shutter, 2module modular base and cover including connection for
telephone and LAN . (Make :Legrand(Myrius)/MK(elements)/schneider(Zencelo)
1.9 Supplying and fixing T.V. antenna socket outlet piano type ISI marked on the NO 1 0.00 0.00 0.00 0.00
existing switchboard / cover including connections etc as requird.
19.1 Supply, delivery and laying of following sizes of 2 mm Wall thickness rigid PVC
Conduit Concealed in Wall/ Column/ Roof Slab of the Building or mounted on
surface along with other accessories and 18 SWG GI Fish Wire complete for
Telephone / TV / Computer / Circuit or Sub main wiring as required & as per
Direction of Engineer-In-Charge.
(a) 20 mm dia. Mtrs. 50 0.00 0.00 0.00 0.00
(b) 25 mm dia. Mtrs. 60 0.00 0.00 0.00 0.00
2 Wiring for Circuits and Submain with following number & sizes of PVC insulated
1100 Volt Grade Multistranded Copper Conductor FRLS Wire run inside 2 mm
thick PVC Conduit Pipe Recessed in Ceiling / Column / Walls of Building including
supply of all materials such as wires, PVC Conduit, Junction Box & Pull Box etc.
complete with making good the damages caused as required and as per
Direction of Engineer-In-Charge. (Make of wire Finolex/Anchor/Havels/KEI)
(a) 2 Nos. Single Core 1.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Mtrs. 40 0.00 0.00 0.00 0.00
Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD (Make of wire Anchor/Havels/KEI)
(b) 2 Nos. Single Core 2.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Mtrs. 30 0.00 0.00 0.00 0.00
Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD (from LDB to Room & Power Point and Common Light Point looped).(Make of
wire Anchor/Havels/KEI)
(c) 2 Nos. Single Core 4.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Mtrs. 25 0.00 0.00 0.00 0.00
Single Core 2.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD.(Make of wire Anchor/Havels/KEI)
(e) 4 Nos. Single Core 16.0 mm2 FRLS Copper Wire for Phase and Neutral and 2 No. Mtrs. 10 0.00 0.00 0.00 0.00
Single Core10 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD.(Make of wire Anchor/Havels/KEI)
3 BRANCH DISTRIBUTION BOARDS:
3.1 Supplying and fixing following way, single pole and neutral, sheet steel, MCB Nos. 1 0.00 0.00 0.00 0.00
distribution board, 240 V, on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including
earthing etc. as required. (But without MCB/RCCB/Isolator).
12 way, Double doorMake:LEGRAND(DX3)/SIEMENS(Betagaurd)/Schneider(Acti
9)/GE
3.2 Supplying and fixing following way, Three pole and neutral, sheet steel, MCB Nos. 1 0.00 0.00 0.00 0.00
distribution board, 415 V, on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, TPN
DB Double door Make:LEGRAND(DX3)/SIEMENS(Betagaurd)/Schneider(Acti 9)/GE
3.3 Supplying and fixing following rating, 63 amp 4pole MCB , (Three phase and Nos. 1 0.00 0.00 0.00 0.00
neutral), 415 V having a sensitivity current 10 KA in the existing MCB DB
complete with connections, testing and commissioning etc. as required.
3.4 Supplying and fixing Single pole 5 amps to 32 amps rating, 240/415 volts, "C" Nos. 12 0.00 0.00 0.00 0.00
curve, miniature circuit breaker suitable for inductive load of following poles in the
existing MCB DB complete with connections, testing and commissioning etc. as
required.
3.5 Supplying and fixing single pole blanking plate in the existing MCB DB complete Nos. 2 0.00 0.00 0.00 0.00
etc. as required.
6 FITTINGS & FIXTURES:
6.1 Supply,Installation and testing of following types of LED Tube Fixtures Directly on
Wall / Ceiling/ Structure of Building with all accessories such as Electronics
Ballast, Lamps, Stove Enameled Box, Perplex Sheet Cover etc. complete assembly
With supply of required T&P and making connection from the suitable point outlet
as per the Direction of Engineer-In-Charge. Make- PHILIPS,WIPRO,LT,TRILUX,
OSRAM,HALONIX
(A) Supply of Surface mounted indoor type 20 WATT LED Inverter LED Batten with Nos. 2 0.00 0.00 0.00 0.00
Opal Diffuser, IP20, Battery back-up & Functioning as per Product TDS complete
assembly With supply of required T&P and making connection from the suitable
point outlet as per the Direction of Engineer-In-Charge(Make-Halonix Cat No LED
INVERTER BATTEN HLB-08-20-CW-INV/WIPRO/CROMPTON/LT/PHILIPS
(B) Supply of 200 watt LED LED Bay Light of die cast aluminium housing with Lens Nos. 4 0.00 0.00 0.00 0.00
embeded PC Cover, IP66 and efficacy of 120lm/W.with Aluminium die cast
housing Luminaire with toughhned glass and unique lens system opal diffuser
,IP66 die cast aluminium housing with LED bay LIGHT 10KV SPD , complete
assembly With supply of required T&P and making connection from the suitable
point outlet as per the Direction of Engineer-In-Charge.Make-HALONIX:HLBLD-
ML54-200-CWDL-R01-HL2 / PHILIPS/WIPRO,LT,BAJAJ,TRILUX, OSHRAM,
C) Supply of 400 watt LED FLOOD Light of die cast aluminium housing with Lens Nos. 6 0.00 0.00 0.00 0.00
embeded PC Cover, IP66 and efficacy of 120lm/W.with Aluminium die cast
housing Luminaire with toughhned glass and unique lens system opal diffuser
,IP66 die cast aluminium housing with LED bay LIGHT 10KV SPD , complete
assembly With supply of required T&P and making connection from the suitable
point outlet as per the Direction of Engineer-In-Charge.Make-HALONIX:HLFLD-
ML27-400-CW-R01 / PHILIPS/WIPRO,LT,BAJAJ,TRILUX, OSHRAM,
D) Supply of 10 W Inverter LED Bulb in B-22 cap and with Opal Diffuser, IP20, Nos. 1 0.00 0.00 0.00 0.00
Battery back-up & Functioning as per Product TDS Luminaire with LED complete
assembly With supply of required T&P and making connection from the suitable
point outlet as per the Direction of Engineer-In-Charge(Make-Make-HALONIX Cat
No 10W B22 CW IP/PHILIPS/WIPRO/CROMPTON
E) Supply of 6 W LED Bulb in B-22 cap and with Opal Diffuser, Functioning as per Nos. 1 0.00 0.00 0.00 0.00
Product TDS Luminaire with LED complete assembly With supply of required
T&P and making connection from the suitable point outlet as per the Direction of
Engineer-In-Charge
6.2 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact Nos 4 0.00 0.00 0.00 0.00
fluorescent fitting of all types, complete with all accessories and tube/lamp etc.
directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC
insulated, copper conductor, single core cable and earthing etc. as required.
6.3 Numbering of ceiling fan/ exhaust fan/ light fittings as required. Nos. 6 0.00 0.00 0.00 0.00
7 Supply, delivery, installation and testing of following Sweeps of High Speed Nos. 1 0.00 0.00 0.00 0.00
Energy Efficient A.C 1200 mm 48 '' Sweep Ceiling Fan 210 CMM Air Delivery..
GOOD BYE Anti Dust Super striker Ceiling Fan complete with Fan Blades, Down
Rod, Canopies & Capacitor etc. including supply of Sundry Materials, making
connection from the suitable point outlet but excluding cost of Fan Regulator
complete as required and as per the Direction of Engineer-In-Charge.(Make-
USHA , Halonix, Pansonic,Bajaj)
8 EARTHING:
8.1 Providing and fixing 25 mm x 5 mm Copper earth strip in 40 mm dia G.I. pipe meter 10 0.00 0.00 0.00 0.00
surface or in recess as strip electrode for connections etc. as required.and
making good the damages caused complete as required and as per direction of
Engineer-in-charge
8.2 Extra for using salt and charcoal for G.I or copper plate earth as required and set 1 0.00 0.00 0.00 0.00
making good the damages caused complete as required and as per direction of
Engineer-in-charge
8.3 Providing and fixing 8 SWG COPPER wire on surface or in recess for loop earthing meter 10 0.00 0.00 0.00 0.00
along with existing surface / recessed conduit / submain wiring / cable as
required and making good the damages caused complete as required and as per
direction of Engineer-in-charge
8.4 Earthing with COPPER plate 600 mm x 600mm x 6 mm thick ISI marked set 1 0.00 0.00 0.00 0.00
including accessories and providing masonary with cover plate having loccking
arrangement and watering pipe etc (But wih out charcoal and salt) as
required.and making good the damages caused complete as required and as per
direction of Engineer-in-charge
CABLE
9 Laying of one number of PVC insulated and PVC seathed / XLPE power cable of Mtr 50 0.00 0.00 0.00 0.00
1.1 KV grade of size excedding 25 sq.mm but not exceeding 100 sq.mm direct in
ground in the same trench in one , sand cushioning, protective covering and
refilling the trench etc. as required.
10 Supply, Laying and Testing of following Size XLPE insulated 1.1 Kv alluminium
armoued cable making good the damages caused as required complete as per
Direction of Engineer-In-Charge. (Make: polycab,KEI)
a) 4 mm2 3 Core Flexiable cooper Cable (flood light) Mtrs. 100 0.00 0.00 0.00 0.00
11 Supply of all materials like cable lugs, gland etc as required & terminal of below
mentioned cable complete as per required technical specifications & direction of
EIC
(a) 50 mm2 3 1⁄2 Core , Al Armoured , XLPE Cable Nos 1 0.00 0.00 0.00 0.00
12 Supplying of following Materials 0.00 0.00 0.00 0.00
a) First Aid Box. Set. 1 0.00 0.00 0.00 0.00
b) Shock Treatment Chart (Odia / Hindi & English). Set 1 0.00 0.00 0.00 0.00
c) 8 mm thick Rubber Mat. Sqmtr. 6 0.00 0.00 0.00 0.00
e) Danger Board. Set 1 0.00 0.00 0.00 0.00
TOTAL ELECTRICALS FOR MAI GATE, SECURITY SHED (C.2) 0.00
TOTAL MAIN GATE, SECURITY SHED (C.1+C.2) 0.00
PART-D BOUNDARY WALL(1200M)
1 Earth work in excavation in all kinds of soil (Ordinary, hard soil & stoney earth Cum 787.32 0.00 0.00 0.00 0.00
soil ) for foundation trenches within 50m. Initial lead and 1.5m initial lift including
rough dressing and beaking clods to maximum 5 cm to 7 cm and laying in layers
not exceeding 0.3 m in depth and as per specification approved by the
department.
2 Filling foundation trenches and plinth with excavated earth including laying the Cum 262.44 0.00 0.00 0.00 0.00
earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all
leads and lifts including cost of all labour, T&P etc. complete as directed by the
Engineer-in-charge.
3 Disposal of excess earth by mechanical means / manually including cost of
loading, unloading, transporting & spreading to a level surface complete in all
respects including cost of all labour, tools & plant etc. to complete the work
A Ground floor
a. Foundation & bases of column Cum 145.8 0.00 0.00 0.00 0.00
b. Plinth Beam Cum 105 0.00 0.00 0.00 0.00
c. Pedestal & Columns Cum 131.16 0.00 0.00 0.00 0.00
d rcc band Cum 52.56 0.00 0.00 0.00 0.00
7 Reinforcement for RCC work including straightening, cutting, bending, placing in
position HYSD and binding all complete. lifting and placing in position as per
design complete including cost of bars , binding wires , including cost of all
materials, labour, conveyance, loading and unloading,, royalties, sundries, tools
and plants, etc. complete as per the direction of the Engineer-in-charge. (linear
measurement will be taken and quantity will be calculated on standard weight for
all heights)-Thermo Mechanically Treated bars
a. Ground floor Cum 593.52 0.00 0.00 0.00 0.00
8 Providing Brick work with Fly ash bricks 25cm x 12cm x 8cm size having
crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2
percent in cement mortar (1:6) ( 1 cement: 6 sand), with all necessary projection,
splay cutting, circular moulding, corbelling, etc., including cost of all materials,
labour, conveyance, loading ,and unloadining, royalties, scaffolding, watering,
curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-
charge.
a. Ground floor Cum 217.92 0.00 0.00 0.00 0.00
9 Providing 16 mm. thick cement plaster in all floors at all height with cement
mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside
rough surface of brick masonry walls after racking out joints including watering
and curing rounding of corners etc. complete with cost, coveyance, loading and
unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries
and scaffolding required for the work etc. with providing grooves as directed by
the Engineer in charge. (Inside)
a. Ground floor Cum 3479.4 0.00 0.00 0.00 0.00
10 Painting to external building surface with weather coat two coats over a coat of
primer of approved shade and quality of approved design after cleaning by
watering & removing the dirts etc. to the surface to be painted including
watering, curing, cost, conveyance of all materials, cost of all labour, brushes,
T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-
charge.
a. Ground floor Cum 3479.4 0.00 0.00 0.00 0.00
11 Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails,
steel windows, steel doors, steel frames for doors and windows, staircase and
parapet railing ( as per I.S. specification and as per approved drawings ) in proper
position in all floors and at all height including making holes to brick walls/ R.C.C
structure/wood work etc. and making good to the damaged walls/ structures
with cement concrete (1:2:4) with black hard crusher broken granite stone chips
of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and
curing etc. complete in all respect as directed by the Engineer in charge ( W.I. /
M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel
windows, steel doors, steel frames for doors and windows, staircase and parapet
railings square bar along with required nos. of nails and screws and other
required materials of approved quality and approved size shall be supplied by the
contractor at his own cost.)
A GROUND FLOOR Cum 45834.6 0.00 0.00 0.00 0.00
12 Providing and painting two coats with synthetic enamel paint over a coat of
primer to iron work of approved quality and approved shade confirmming to ISI
on steel work to give an even shade in all floors at all height over a coat of primer
of approved quality and shade including sand papering and making the surface
smooth with cost, coveyance, loading and unloading, of all materials, cost of all
labour, sundries, T&P, scaffolding etc. required for the work and complete in all
respect as directed by Engineer-in-charge.
A GROUND FLOOR Cum 65.52 0.00 0.00 0.00 0.00
TOTAL BOUNDARY WALL(1200M) (D) 0.00
PART-E TRANSIT HOUSE
E.1 TRANSIT HOUSE CIVIL WORK (E.1)
1 Earthwork excavation in all kinds of soil as per drawing and technical specification Cum 209.65 0.00 0.00 0.00 0.00
including dressing and levelling the bed, sides and bottom and removing the
excavated earth and depositing the same away from the work site within initial
lead of 50m and initial lift of 1.5m, including cost, conveyance of all materials, all
labour, T&P articles required for the work, including shoring, shuttering, propping
and dewatering if required etc. complete in all respect as per direction of the
Engineer-in-Charge.
2 Extra lift or 1.5m or part there of over the initial lift of 1.5m in all kinds of Cum 74.23 0.00 0.00 0.00 0.00
embankments and road works and ordinary earth work in general.
3 Cutting in disintegrated rock not requiring blasting to be removed by pick axes Cum 139.77 0.00 0.00 0.00 0.00
and crow bars and depositing materials within 50m initial lead and 1.5m initial lift
including rough dressing as per direction and specification of the department
including stacking the useful materials separately as ordered.
4 Back filling available excavated earth (excluding rock) in trenches, plinth, sides of Cum 69.89 0.00 0.00 0.00 0.00
foundations etc. in layers not exceeding 20 cm in depth, consolidating each
deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
4 Carriage / disposal of excavated surplus earth from the worksite by mechanical Cum 279.53 0.00 0.00 0.00 0.00
means within a lead of 5Km including loading and unloading etc. complete. in all
respect as per direction of Engineer-in-Charge.
5 Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers Cum 345.30 0.00 0.00 0.00 0.00
including watering and ramming with cost, conveyance, royalties and taxes of
sand with labour and T&P required for the work etc. complete (Measurement will
be taken on finished compacted section only).
6 Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation and Cum 56.37 0.00 0.00 0.00 0.00
floors using 4cm (1 1/2") 0 mm & down grade black hard crusher broken granite
stone metal, washed and screened sharp sand of approved quality from approved
quarry including hoisting, lowering, laying the concrete, ramming, watering and
curing etc. complete to required thickness including cost of all materials,
conveyance, loading, unloading,cost of labours, T&P, hire & running charges of
concrete mixer, etc. all complete as per the direction of the Engineer -in -charge.
7 Providing & laying Plain cement concrete (1:2:4) using 12mm size black hard
crusher broken granite chips of approved quality from approved quarry including
hoisting, lowering and laying concrete in layers, watering, curing etc. complete
including cost, conveyance, royalties and taxes of all materials with labour, cess
and T&P etc. required for the work complete.
A GROUND FLOOR
a Foundation & bases of column cum 72.14 0.00 0.00 0.00 0.00
b Plinth Beam cum 13.07 0.00 0.00 0.00 0.00
c Pedestal & Columns cum 19.95 0.00 0.00 0.00 0.00
d Roof Beam cum 13.60 0.00 0.00 0.00 0.00
e Lintel cum 2.28 0.00 0.00 0.00 0.00
f Chajja sqm 15.45 0.00 0.00 0.00 0.00
g R.C.C. floor and roof slab cum 20.83 0.00 0.00 0.00 0.00
h R.C.C. staircase cum 3.43 0.00 0.00 0.00 0.00
B FIRST FLOOR & HEAD ROOM
a Columns cum 6.77 0.00 0.00 0.00 0.00
b Roof Beam cum 12.91 0.00 0.00 0.00 0.00
c Lintel cum 2.63 0.00 0.00 0.00 0.00
d Chajja sqm 3.44 0.00 0.00 0.00 0.00
e R.C.C. floor and roof slabs cum 23.14 0.00 0.00 0.00 0.00
f R.C.C. staircase cum 3.43 0.00 0.00 0.00 0.00
9 Cutting, straightening coiled or bent up M.S. rods, HYSD steel or Tor Steel
welding or jointing if necessary, bending, binding, tying the grills as required for
RCC works, and hoisting, lowering and placing in proper position according to
approved designs and drawings including cost, conveyance, loading, unloading,
M.S. rods, HYSD steel or Tor steel and binding wires of 18 to 20 gauge required
for the work and cost of all labour, sundries, T&P and scaffolding complete in all
respect as directed by the Engineer-in-Charge (payment will be made according
to the actual weight of M.S. rod, HYSD steel or Tor steel consumed in the work
and no separate payment will be made towards weight of binding wires which is
to be borne by the contractor at his own cost).
A GROUND FLOOR Qntl 187.46 0.00 0.00 0.00 0.00
B FIRST FLOOR Qntl 64.99 0.00 0.00 0.00 0.00
10 Fly Ash brick masonry using fly ash bricks of size 25 cm. x 12 cm. x 8 cm. having
crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6)
with ordinary portland cement (OPC) and screened & washed sand for mortar
after immersing the bricks for 6 (Six) hours in water before use including splays
cutting, circular moulding, corbelling, chamfering and similar such type of works,
watering and curing etc. including cost, conveyance, loading, unloading, royalties
of all materials, cost of all labour, scaffolding, sundries, T&P required for the
works etc. complete in all respect as directed by the Engineer-in-charge
A Foundation & Plinth Cum 28.43 0.00 0.00 0.00 0.00
B GROUND FLOOR Cum 57.24 0.00 0.00 0.00 0.00
C FIRST FLOOR & HEAD ROOM Cum 61.31 0.00 0.00 0.00 0.00
11 Fly Ash brick masonry using fly ash bricks of size 25 cm. x 12 cm. x 8 cm. having
crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:4)
with ordinary portland cement (OPC) and screened & washed sand for mortar
after immersing the bricks for 6 (Six) hours in water before use in Superstructure
including splays cutting, circular moulding, corbelling, chamfering and similar such
type of works, watering and curing etc. including cost, conveyance, loading,
unloading, royaltiesof all materials, cost of all labour, scaffolding, sundries, T&P
required for the works etc. complete in all respect as directed by the Engineer-in-
charge
A GROUND FLOOR cum 2.67 0.00 0.00 0.00 0.00
B FIRST FLOOR & HEAD ROOM cum 2.25 0.00 0.00 0.00 0.00
12 Providing 16 mm. thick cement plaster (1:6) finished smooth to inside brick walls
after racking out the joints including watering and curing with cost, conveyance,
loading, unloading, royalties of all materials, cost of all labour, T&P, sundries and
scaffolding required for the work etc. with providing grooves as directed by the
Engineer in charge.
A GROUND FLOOR Sqm 402.87 0.00 0.00 0.00 0.00
B FIRST FLOOR & HEAD ROOM Sqm 454.42 0.00 0.00 0.00 0.00
13 Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces
such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams
and lofts etc. including roughening/chipping, scraping and cleaning and finishing
the plastered surface smooth using wooden floats, bars, etc. only to proper
plumbs and level, making grooves, beads and drip coarse to give required
ornamental finish as per drawing including cost of all materials, conveyance,
loading and unloading, royalties, cost of all labour, scaffolding, staging, watering
before plastering and curing, sundries and T&P, etc. complete as per direction of
the Engineer-in-charge.
A FIRST FLOOR & HEAD ROOM Sqm 214.38 0.00 0.00 0.00 0.00
36 Providing & applying of pre constructional anti-termite treatment by drilling 12mm Sqm 148.46 0.00 0.00 0.00 0.00
dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep
enough to reach the soil below & chemical emulsion (PREMISE, IMIDACHLOPRIED
30.5SC OF BAYER MAKE mixed with 47.5ltr water) pumped these holes to soak
the soil @ 1 ltr solution of each hole as per manufactures specification & the holes
should be pluged the filling materials including cost of all materials,
labour,conveyance, T&P , all taxes and hire charges of machinaries as per
direction of Engineer-in-charge.
37 Providing and fixing of UPVC sliding windows 2 /3track sliding-60 series/Top
hung ventilator of any approved make ,duly manufactured using upvc reinforced
profiles of 62mm x 60mm x 2.25mm for outer frame, 66mm x 38mm x 2.25mm
for sliding shutter frames capable of mounting single glazing system,structurally
reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.2
mm prefabricated and welded through fusion welding & the window sash shall be
fitted with 5 mm thick clear float glass of reputed make duly fixed with EPDM
weathering seal including the cost of all materials,necessary locking arrangements
,fittings,cost of labour,T&P ,etc complete as per direction of Engineer-in-charge.
8 Providing 12 mm. thick cement plaster in all floors at all height with cement SQM 122.50 0.00 0.00 0.00 0.00
mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside
rough surface of brick masonry walls after racking out joints including watering
and curing rounding of corners etc. complete with cost, coveyance, loading and
unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries
and scaffolding required for the work etc. with providing grooves as directed by
the Engineer in charge.
Total COVERED DRAIN FOR TRANSIT HOUSE (E.2) 0.00
E.3 PLINTH PROTECTION FOR TRANSIT HOUSE
1 Earth work in excavation in all kinds of soil (Ordinary, hard soil & stoney earth CUM 7.00 0.00 0.00 0.00 0.00
soil ) for foundation trenches within 50m. Initial lead and 1.5m initial lift including
rough dressing and beaking clods to maximum 5 cm to 7 cm and laying in layers
not exceeding 0.3 m in depth and as per specification approved by the
department.
2 Supplying, filling in foundation and plinth with sand including watering and CUM 7.88 0.00 0.00 0.00 0.00
ramming with cost, conveyance, royalties of sand with labour and T&P required
for the work etc. complete (Measurement will be taken on finished compacted
section only).
3 Providing & laying Plain Cement concrete (PCC ) of proportion (1:4:8) in CUM 3.15 0.00 0.00 0.00 0.00
foundation and floors using 4cm (1½”) size clean hard black crusher broken
granite stone metal of approved quality and from approved quarry including
hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to
the required level ramming, watering, curing etc. complete including cost,
conveyance, royalties and ,es of all materials with all labour, cess and T&P
required for the work etc. complete in all respect.
4 Providing & laying Plain cement concrete (1:2:4) using 12mm size black hard CUM 2.10 0.00 0.00 0.00 0.00
crusher broken granite chips of approved quality from approved quarry including
hoisting, lowering and laying concrete in layers, watering, curing etc. complete
including cost, conveyance, royalties of all materials with labour, cess and T&P
etc. required for the work complete.
5 Providing Brick work with Fly ash bricks 23cm x 11cm x 8cm size having CUM 8.40 0.00 0.00 0.00 0.00
crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2
percent in cement mortar (1:6) ( 1 cement: 6 sand), with all necessary projection,
splay cutting, circular moulding, corbelling, etc., including cost of all materials,
labour, conveyance, loading ,and unloadining, royalties, scaffolding, watering,
curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-
charge.
6 Providing 12 mm. thick cement plaster in all floors at all height with cement SQM 35.00 0.00 0.00 0.00 0.00
mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside
rough surface of brick masonry walls after racking out joints including watering
and curing rounding of corners etc. complete with cost, coveyance, loading and
unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries
and scaffolding required for the work etc. with providing grooves as directed by
the Engineer in charge.
Total PLINTH PROTECTION FOR TRANSIT HOUSE (E.3) 0.00
E.4 TRANSIT HOUSE ELECTRICALS
All the electrical work as mentioned below shall be complete in all
aspect for proper, safe operation and as per instruction of site engineer
including the cost of all material & accessories, T & P, labour as
required.
1.1(a) GROUP A :Wiring for light point/ fan point/ exhaust fan point/ call bell point with Nos. 10 0.00 0.00 0.00 0.00
1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /
recessed medium class PVC conduit, with modular switch, modular plate, suitable
GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable etc. as required. ((Make
:Legrand(Myrius)/MK(elements)/Pansonic(Europa)/Hager(Insysta)/Eq
make
(b) GROUP B: Wiring for light point/ fan point/ exhaust fan point/ call bell point Nos. 10 0.00 0.00 0.00 0.00
with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface
/ recessed medium class PVC conduit, with modular switch, modular plate,
suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable etc. as required. ((Make
:Legrand(Myrius)/MK(elements)/Pansonic(Europa)/Hager(Insysta)/Eq
make
(c) GROUP C: Wiring for light point/ fan point/ exhaust fan point/ call bell point Nos. 20 0.00 0.00 0.00 0.00
with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface
/ recessed medium class PVC conduit, with modular switch, modular plate,
suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable etc. as required. ((Make
:Legrand(Myrius)/MK(elements)/Pansonic(Europa)/Hager(Insysta)/Eq
make
(b) Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call Nos. 10 0.00 0.00 0.00 0.00
bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated
copper conductor single core cable in surface/ recessed PVC conduit, and earthing
the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable
etc. as required. ((Make
:Legrand(Myrius)/MK(elements)/Pansonic(Europa)/Hager(Insysta)/Eq
make
(e) Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated Nos. 8 0.00 0.00 0.00 0.00
single core multistrand copper conductor of ISI marked in recess 20 mm dia non-
metalic PVC flexible conduit with modular type switch ,4 module 18SWG modular
GI box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core
multistrand copper conductor for loop earthing etc. as required. ( Make of wire
Finolex / Anchor / Havels / V Guard/KEl )
1.2 Supplying and fixing of 4module GI box with cover on surface or in recess with Nos. 8 0.00 0.00 0.00 0.00
suitable size of phenolic laminated sheet cover in front including providing and
fixing 5 pin 15 / 16 amps socket outlet and 15 / 16 amps modular type switch,
connection, painting etc as required.(Make-Anchor/crabtree/Legrand)
1.3 Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated Nos. 8 0.00 0.00 0.00 0.00
single core multistrand copper conductor of ISI marked in recess 20 mm dia non-
metalic PVC flexible conduit with modular type switch ,6 module 18SWG modular
GI box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core
multistrand copper conductor for loop earthing etc. as required. ( Make of wire
Finolex / Anchor / Havels /KEI )
1.4 Supplying and fixing of 100W,step type regulator, 2 Module without base and Nos. 8 0.00 0.00 0.00 0.00
cover including connection etc as required.(Make
:Legrand(Myrius)/MK(elements)/schneider(Zencelo)
1.5 Supplying and fixing modular blanking plate on the existing modular plate & Nos. 2 0.00 0.00 0.00 0.00
switch box excluding modular plate as required.
1.6 2
Wiring to Telephone Socket Outlet from Junction Box with 0.5 mm Twin Pair Mtrs. 80 0.00 0.00 0.00 0.00
Copper Conductor Telephone Wire run inside prelaid PVC Conduit complete
including termination, testing etc complete as required and as per Direction of
Engineer-In-Charge. (Make
:Legrand(Myrius)/MK(elements)/schneider(Zencelo)
1.7 Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe Mtrs. 80 0.00 0.00 0.00 0.00
and making good the damages caused complete as required and as per Direction
of Engineer-In-Charge. (Make
:Legrand(Myrius)/MK(elements)/schneider(Zencelo)
1.8 Supplying and fixing of RJ11 telephone jack single with shutter & RJ 45 computer NO 4 0.00 0.00 0.00 0.00
jack with shutter, 2module modular base and cover including connection for
telephone and LAN . (Make
:Legrand(Myrius)/MK(elements)/schneider(Zencelo)
1.9 Supplying and fixing T.V. antenna socket outlet piano type ISI marked on the NO 4 0.00 0.00 0.00 0.00
existing switchboard / cover including connections etc as requird.
19.1 Supply, delivery and laying of following sizes of 2 mm Wall thickness rigid PVC
Conduit Concealed in Wall/ Column/ Roof Slab of the Building or mounted on
surface along with other accessories and 18 SWG GI Fish Wire complete for
Telephone / TV / Computer / Circuit or Sub main wiring as required & as per
Direction of Engineer-In-Charge.
(a) 20 mm dia. Mtrs. 40 0.00 0.00 0.00 0.00
(b) 25 mm dia. Mtrs. 45 0.00 0.00 0.00 0.00
2 Wiring for Circuits and Submain with following number & sizes of PVC insulated
1100 Volt Grade Multistranded Copper Conductor FRLS Wire run inside 2 mm
thick PVC Conduit Pipe Recessed in Ceiling / Column / Walls of Building including
supply of all materials such as wires, PVC Conduit, Junction Box & Pull Box etc.
complete with making good the damages caused as required and as per
Direction of Engineer-In-Charge. (Make of wire
Finolex/Anchor/Havels/KEI)
(a) 2 Nos. Single Core 1.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Mtrs. 200 0.00 0.00 0.00 0.00
Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD (Make of wire Anchor/Havels/KEI)
(b) 2 Nos. Single Core 2.5 mm
2 FRLS
Copper Wire for Phase and Neutral and 1 No. Mtrs. 150 0.00 0.00 0.00 0.00
2
Single Core 1.5 mm FRLS Copper Wire for Earth Continuity Conductor as per
SLD (from LDB to Room & Power Point and Common Light Point looped).(Make
of wire Anchor/Havels/KEI)
(c) 2 Nos. Single Core 4.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Mtrs. 100 0.00 0.00 0.00 0.00
Single Core 2.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD.(Make of wire Anchor/Havels/KEI)
(d) 2
4 Nos. Single Core 16.0 mm FRLS Copper Wire for Phase and Neutral and 2 No. Mtrs. 80 0.00 0.00 0.00 0.00
Single Core10 mm2 FRLS Copper Wire for Earth Continuity Conductor as per
SLD.(Make of wire Anchor/Havels/KEI)
3 BRANCH DISTRIBUTION BOARDS:
3.1 Supplying and fixing following way, Three pole and neutral, sheet steel, MCB Nos. 2 0.00 0.00 0.00 0.00
distribution board, 415 V, on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way,
TPN DB Double door
Make:LEGRAND(DX3)/SIEMENS(Betagaurd)/Schneider(Acti 9)/GE
3.2 Supplying and fixing following rating, 63 amp 4pole MCB , (Three phase and Nos. 2 0.00 0.00 0.00 0.00
neutral), 415 V having a sensitivity current 10 KA in the existing MCB DB
complete with connections, testing and commissioning etc. as
required.Make:LEGRAND(DX3)/SIEMENS(Betagaurd)/Schneider(Acti
9)/GE
3.3 Supplying and fixing 5 amps to 32 amps rating,Single pole 240/415 volts, "C" Nos. 20 0.00 0.00 0.00 0.00
curve, miniature circuit breaker suitable for inductive load of following poles in the
existing MCB DB complete with connections, testing and commissioning etc. as
required.
3.6 Supplying and fixing single pole blanking plate in the existing MCB DB complete Nos. 5 0.00 0.00 0.00 0.00
etc. as required.
4 MAIN DISTRIBUTION BOARD
Supplying, Installing, Testing and Energizing TYPE TESTED IEC61439 Panel Board
made of 2 mm thick CRCA Sheet with Hinged Door duly Fabricated with required
MS Angle and Channels of adequate size, duly treated and Powder Coated (shall
have Hinged Door at the Front and Detachable Plates at Back if requirement and
at Top / Bottom for Cable / Wire Entry / Exit as per the Direction of Engineer-In-
Charge and approved GA Drawing with following provisions. MAKE-L&T /
LEGRAND / C&S)
Main Panel Board: 100 Amp. 4P MCCB 36 KA (Thermal Magnetic Release) - set 1 0.00 0.00 0.00 0.00
1No,125 AMP 4WAY AUTO CHANGOVER SWITCH 1 NO,Equiments: 4 Nos. 1250
Amp. Copper Bus Bar coated with PVC Heat Shrunk Sleeve (Colour Code). 1 No.
VAF Digital Meter.3 Nos. RYB LED Indicator. 3 Nos.100 / 5 Amp. C.T. Operated.
Outgoing:3 NOS 63 Amp 4p MCB 10 KA, 3 Nos 40 AMP 2P MCB 10 KA,1 Nos of
sub Meter connection With spreadentinle & cable alloy 1no. Digital multi function
meter semealess integration ,industry standard modbus rtu protccol HMI LCD
display with following parameters displayed - Phase Current, Neutral Current,
Ground Current, Voltage Line-to-Line, Voltage Line-to-Neutral, Frequency, Real
Power (kW), Apparent Power (kVA), Power Factor, Energy (kW-Hours,
6 FITTINGS & FIXTURES:
6.1 Supply,Installation and testing of following types of LED Tube Fixtures Directly on
Wall / Ceiling/ Structure of Building with all accessories such as Electronics
Ballast, Lamps, Stove Enameled Box, Perplex Sheet Cover etc. complete assembly
With supply of required T&P and making connection from the suitable point outlet
as per the Direction of Engineer-In-Charge. Make- PHILIPS,
,WIPRO,LT,PANASONIC,BAJAJ,TRILUX, PAC,HALONIX/Eq make
(A) Supply of Surface mounted indoor type 20 WATT LED Inverter LED Batten with Nos. 10 0.00 0.00 0.00 0.00
Opal Diffuser, IP20, Battery back-up & Functioning as per Product TDS complete
assembly With supply of required T&P and making connection from the suitable
point outlet as per the Direction of Engineer-In-Charge(Make-Halonix Cat No LED
INVERTER BATTEN HLB-08-20-CW-INV/WIPRO/CROMPTON/LT/PHILIPS
(B) Supply of 18 watt Surface mounted indoor type Round LED Luminaire with Nos. 15 0.00 0.00 0.00 0.00
LED GLARE FREE opal diffuser ,IP20 Lamp complete assembly With supply of
required T&P and making connection from the suitable point outlet as per the
Direction of Engineer-In-Charge.
C) Supply 36 W LED premises LIGHT 6500 CCT complete assembly With supply of Nos. 2 0.00 0.00 0.00 0.00
required T&P and making connection from the suitable point outlet as per the
Direction of Engineer-In-Charge
E) Supply of 10 W LED Bulb in B-22 cap and with Opal Diffuser, Functioning as per Nos. 5 0.00 0.00 0.00 0.00
Product TDS Luminaire with LED complete assembly With supply of required
T&P and making connection from the suitable point outlet as per the Direction of
Engineer-In-Charge
F) Supply of 6 W LED Bulb in B-22 cap and with Opal Diffuser, Functioning as per Nos. 6 0.00 0.00 0.00 0.00
Product TDS Luminaire with LED complete assembly With supply of required
T&P and making connection from the suitable point outlet as per the Direction of
Engineer-In-Charge
6.2 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact Nos 38 0.00 0.00 0.00 0.00
fluorescent fitting of all types, complete with all accessories and tube/lamp etc.
directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC
insulated, copper conductor, single core cable and earthing etc. as required.
6.3 Numbering of ceiling fan/ exhaust fan/ light fittings as required. Nos. 50 0.00 0.00 0.00 0.00
7 Supply, delivery, installation and testing of following Sweeps of High Speed Nos. 8 0.00 0.00 0.00 0.00
Energy Efficient A.C 1200 mm 48 '' Sweep Ceiling Fan 210 CMM Air Delivery..
GOOD BYE Anti Dust Super striker Ceiling Fan complete with Fan Blades, Down
Rod, Canopies & Capacitor etc. including supply of Sundry Materials, making
connection from the suitable point outlet but excluding cost of Fan Regulator
complete as required and as per the Direction of Engineer-In-Charge.(Make-
USHA , Halonix ,Bajaj)
7.1 Supply, delivery, installation & testing of following Sweep & Speed 230 mm Nos. 5 0.00 0.00 0.00 0.00
EXHAUST FAN 1400 RPM. on Existing Sheet Metal Switch Board including loop
connections and making good the damages caused complete as required and as
per direction of Engineer-in-charge(Make-USHA , Halonix ,Bajaj)
8 EARTHING:
8.1 Providing and fixing 25 mm x 5 mm Copper earth strip in 40 mm dia G.I. pipe meter 30 0.00 0.00 0.00 0.00
surface or in recess as strip electrode for connections etc. as required.and
making good the damages caused complete as required and as per direction of
Engineer-in-charge
8.2 Extra for using salt and charcoal for G.I or copper plate earth as required and set 2 0.00 0.00 0.00 0.00
making good the damages caused complete as required and as per direction of
Engineer-in-charge
8.3 Providing and fixing 8 SWG COPPER wire on surface or in recess for loop earthing Mtrs. 35 0.00 0.00 0.00 0.00
along with existing surface / recessed conduit / submain wiring / cable as
required and making good the damages caused complete as required and as per
direction of Engineer-in-charge
8.4 Earthing with COPPER plate 600 mm x 600mm x 6 mm thick ISI marked set 2 0.00 0.00 0.00 0.00
including accessories and providing masonary with cover plate having loccking
arrangement and watering pipe etc (But wih out charcoal and salt) as
required.and making good the damages caused complete as required and as per
direction of Engineer-in-charge
CABLE 0.00 0.00 0.00 0.00
9 Laying of one number of PVC insulated and PVC seathed / XLPE power cable of Mtr 50 0.00 0.00 0.00 0.00
1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in
ground in the same trench in one , sand cushioning, protective covering and
refilling the trench etc. as required.
10 Supply, Laying and Testing of following Size XLPE insulated 1.1 Kv alluminium
armoued cable making good the damages caused as required complete as per
Direction of Engineer-In-Charge. (Make: polycab,KEI)
a) 2
50 mm 3 1⁄2 Core , Al Armoured , XLPE Cable Mtrs. 90 0.00 0.00 0.00 0.00
11 Supply of all materials like cable lugs, gland etc as required & terminal of below
mentioned cable complete as per required technical specifications & direction of
EIC
(a) 50 mm2 3 1⁄2 Core , Al Armoured , XLPE Cable Nos 2 0.00 0.00 0.00 0.00
12 Supplying of following Materials
a) First Aid Box. Set. 1 0.00 0.00 0.00 0.00
b) Shock Treatment Chart (Odia / Hindi & English). Set 1 0.00 0.00 0.00 0.00
c) 8 mm thick Rubber Mat. Sqmtr. 12 0.00 0.00 0.00 0.00
d) ABS type Fire Extinguisher of 4.5 Kg. Set 2 0.00 0.00 0.00 0.00
e) Danger Board. Set 1 0.00 0.00 0.00 0.00
TOTAL TRANSIT HOUSE ELECTRICALS-(E.4) 0.00
E.5 TRANSIT HOUSE PH WORK
A WATER SUPPLY & SANITARY WORKS
1 Providing, Supplying & Fixing of Rimless, Blind Installation wall Hung WC of CERA EACH 5.00 0.00 0.00 0.00 0.00
(CAT NO S1059102and Cistern-B1510121), (Size :520x360x390mm) with PP soft
close slim seat cover (Cat. No. B1510121 Cajol seat cover), Hinges, Accessories
with all fittings & fixtures complete including making good the damages .
including cost of all materials, labour, T&P, lead, royality etc.complete in all
respects as per direction of Architect /Engineer in charge.
2 Providing, Supplying & Fixing of Toilet roll Holder with Stainless steel flap of CERA EACH 5.00 0.00 0.00 0.00 0.00
(CAT- F5001109) with all fittings & fixtures complete including making good the
damages . including cost of all materials, labour, T&P, lead, royality etc.complete
in all respects as per direction of Architect /Engineer in charge.
3 Providing, Supplying & Fixing of Hand Shower (Health Faucet) with 8mm dia, each 5.00 0.00 0.00 0.00 0.00
1.2m long flexible tube and wall hook of CERA (F8030103)with all fittings &
fixtures complete including making good the damages . including cost of all
materials, labour, T&P, lead, royality etc.complete in all respects as per direction
of Architect /Engineer in charge.
4 Providing, Supplying & Fixing of Stop cock, male end with wall flange of each 5.00 0.00 0.00 0.00 0.00
CERA(F1018201) will all fittings & fixtures complete including making good the
damages including cost of all materials, labour, T&P, lead, royality etc. complete
in all respects as per direction of Architec/Engineer in charge.
5 Providing, Supplying & Fixing of 2 Way Bib cock with wall flange of CERA each 5.00 0.00 0.00 0.00 0.00
(F1018163) with all fittings & fixtures complete including making good the
damages. including cost of all mateials, labour, T&P, lead, royality etc. complete
in all respects as per direction of Architect/Engineer in charge.
6 Providing, Supplying & Fixing Basin of CERA of size 515x410x195 mm (CAT-NO. EACH 5.00 0.00 0.00 0.00 0.00
S2040120) with full pedestal height 850MM (CAT NO. S2090113 ) with all fitings
& fixtures complete including cost of all materials, labour, T&P, lead, royality etc.
complete in all respects as per direction of Architect/ Engineer in charge
7 Providing, Supplyin & Fixing of Basin inlet connection (angle valve) of CERA EACH 5.00 0.00 0.00 0.00 0.00
(F1018201) with all fittings & fixtures complete including cost of all materials,
labour, T&P, lead, royality etc. complete in all respects as per direction of
Architect/Engineer in charge.
8 Providing, Supplying & Fixing Glass Shelf 300X300mm long of CERA (F5005103) EACH 5.00 0.00 0.00 0.00 0.00
with all fittings & fixtures complete including making good the damages. including
cost of all materials, labour, T&P, lead, royality etc. complete in all respects as per
direction of Architect/Engineer in charge.
9 Providing, Supplying & Fixing pillar cock with aerator with long screws, shanks each 5.00 0.00 0.00 0.00 0.00
and back nuts of CERA (CAT-F2007101) with all fittings & fixtures complete
including making good the damages. including cost of all materials, labour, T&P,
lead, royality etc. complete in all respects as per direction of Architect/Engineer in
charge.
10 Providing, Supplying & Fixing standard sized Single Towel rail of 600mm long, each 5.00 0.00 0.00 0.00 0.00
stainless steel complete with Chromiun Plated brass brackets of CERA (F5003103)
with all fittings & fixtures complete including making good the damages. including
cost of all materials, labour, T&P, lead, royality etc. complete in all rescpects as
per direction of Architect/ Engineer in charge.
11 Providing, Supplying & Fixing standard sized Chromium Plated brass towel EACH 5.00 0.00 0.00 0.00 0.00
ring(round) of CERA (F5003105) with all fittings & fixtures complete including
making good the damages. including cost of all materials, labour, T&P, lead,
royalitity etc. complete in all respects as per direction of Architect/Engineer in
charge.
12 Providing, Supplying & Fixing Soap dish holder of CERA (F5007105) with all EACH 10.00 0.00 0.00 0.00 0.00
fittings & fixtures complete including making good the damages. including cost of
all materials, labour, T&P, lead, royality etc. complete in all respects as per
direction of Architect/Engineer in charge.
13 Providing, Supplying & Fixing Towel Shelf 600mm long with lower hangers, EACH 5.00 0.00 0.00 0.00 0.00
stainless steel complete with Chromiun Plated brass brackets ofCERA (F5007101)
with all fittings & fixtures completer including making good the damages.
including cost of all materials, labour, T&P, lead, royality etc. complete in all
respects as per direction of Architect/Engineer in charge.
14 Providing, Supplying & Fixing of Bib cock short body (with straight line model) each 5.00 0.00 0.00 0.00 0.00
with wall flange polished bright ofCERA (F2013151) with all fittings & fixtures
completer including making good the damages. including cost of all materials,
labour, T&P, lead, royality etc. complete in all respects as per direction of
Architect/Engineer in charge.
15 Providing, Supplying & Fixing of Long body Bib cock with wall flange polished each 5.00 0.00 0.00 0.00 0.00
bright of CERA (CAT-SQT-512KN) with all fittings & fixtures completer including
making good the damages. including cost of all materials, labour, T&P, lead,
royality etc. complete in all respects as per direction of Architect/Engineer in
charge.
16 Providing, Supplying & Fixing Overhead shower 70mm Round shape single flow each 5.00 0.00 0.00 0.00 0.00
(ABS Body Chorme plated with Gray face plate) with Rubit cleaning system (EOS-
542A) and Shower arm 235mm long (Light weight) round shape for wall mounted
showers with wall flange (ALE-536A) of CERAwith all fittings & fixtures completer
including making good the damages. including cost of all materials, labour, T&P,
lead, royality etc. complete in all respects as per direction of Architect/Engineer in
charge.
17 Providing, Supplying & Fixing of Concealed Stop cock, Heavy Body with Cap of each 5.00 0.00 0.00 0.00 0.00
CERA (F1018201) with all fittings & fixtures completer including making good the
damages. including cost of all materials, labour, T&P, lead, royality etc. complete
in all respects as per direction of Architect/Engineer in charge.
18 Providing, Supplying & Fixing Double Coat hook ofCERA (F5003108) with all each 5.00 0.00 0.00 0.00 0.00
fittings & fixtures completer including making good the damages. including cost of
all materials, labour, T&P, lead, royality etc. complete in all respects as per
direction of Architect/Engineer in charge.
19 Providing, Supplying & Fixing 600mm x 300mm bevelled edge mirror of superior EACH 5.00 0.00 0.00 0.00 0.00
glass mounted on 5mm thick A.C sheet or plywood sheet with all fittings &
fixtures completer including making good the damages. including cost of all
materials, labour, T&P, lead, royality etc. complete in all respects as per direction
of Architect/Engineer in charge.
20 Providing & Fixing of PVC nahani trap with 125mm stainless steel grating with/ without EACH 10.00 0.00 0.00 0.00 0.00
hole for waste pipe in floors / at any location cost includes all materials, labour,
tools,plant etc. complete in all respects.as per price list of ASTRAL
21 Providing, Supplying and Fixing Stainless Stell A ISI 304 (18/8) wash Kitchen sink EACH 1.00 0.00 0.00 0.00 0.00
conforming to IS 13983 with C.I. Brackets, stainless steel waste coupling, 32mm dia PVC
waste pipe and stainless steel plug 40 mm including painting of fittings and brackets of
Parryware (CAT-C856299) with all fittings & fixtures complete including making good
the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in
all respects as per direction of Architect /Engineer in charge.
22 Fixing of sink cock with swinging long swivel spout (wall mounted model) with Aerator EACH 1.00 0.00 0.00 0.00 0.00
of CERA(CAT-F1003251) with all fittings & fixtures complete including making good
the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in
all respects as per direction of Architect /Engineer in charge.
23 Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste
ventilating pipes (type-A / ring fit type ) with all PVC fittings of
ASTRAL/AJAY/SUPREME make as per IS 13592 to walls with nails, bobbins and
laying in trenches including all pipe fittings, jointing materials, tools plant, labour
& all material, earthwork in excavation in all kinds of soil and refilling of trenches
as per specification and direction of the engineer in charge.
a) 160mm dia PVC (SWR) pipe class "A" ( with wall thickness of 3.2mm to 3.8mm) MTR 35.00 0.00 0.00 0.00 0.00
b) 110 mm dia PVC (SWR) pipe Class „A‟ (with wall thick of 2.20 mm to 2.70 mm) MTR 50.00 0.00 0.00 0.00 0.00
c) 75 mm dia PVC (SWR) pipe Class „A‟ (with wall thick of 1.8 mm to 2.20 mm ) MTR 50.00 0.00 0.00 0.00 0.00
25 Providing all materials, labour and T&P for fixing of Upvc SWR fittings
a 75 x 75 x 75mm single Tee with door Each 8.00 0.00 0.00 0.00 0.00
b 110 x 110 x 110 mm single Tee with door Each 8.00 0.00 0.00 0.00 0.00
c 75 x 75 x 75mm single Tee without door Each 6.00 0.00 0.00 0.00 0.00
d 110 x 110 x 110 mm single Tee without door Each 6.00 0.00 0.00 0.00 0.00
e 160 x 160x 110 mm Reducing Tee with door Each 10.00 0.00 0.00 0.00 0.00
f 110 x 110 x 75 mm Reducing Tee with door Each 10.00 0.00 0.00 0.00 0.00
g 75 mm x 87.50 Plane Bend Each 15.00 0.00 0.00 0.00 0.00
h 110 mm x 87.50 Plane Bend Each 15.00 0.00 0.00 0.00 0.00
i 75mm coupler Each 15.00 0.00 0.00 0.00 0.00
j 110mm coupler Each 30.00 0.00 0.00 0.00 0.00
k 75 mm vent cowl with SS Jali Each 8.00 0.00 0.00 0.00 0.00
l 110 mm vent cowl with SS Jali Each 8.00 0.00 0.00 0.00 0.00
m 75mm pipe clip Each 50.00 0.00 0.00 0.00 0.00
n 110mm pipe clip Each 50.00 0.00 0.00 0.00 0.00
o 160mm pipe clip Each 50.00 0.00 0.00 0.00 0.00
p 110 mm x 75 mm Nahani Trap without Jali Each 10.00 0.00 0.00 0.00 0.00
q 110 mm Square Gully Trap Each 6.00 0.00 0.00 0.00 0.00
r 125 x 110mm WC Connector Each 6.00 0.00 0.00 0.00 0.00
s 110mm WC Connector (Bend) Each 6.00 0.00 0.00 0.00 0.00
t 110mm WC Connector (Straight) Each 6.00 0.00 0.00 0.00 0.00
24 Providing and laying in trench cement concrete ( 1:4:8 ) with 40mm size hard MTR 100.00 0.00 0.00 0.00 0.00
granite metal in the following type of bedding for 150mm diameter including
curing complete as per specification
25 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of (
ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal
stability for hot & cold water supply SDR 11 , including all CPVC plain & brass
threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step CPVC solvent cement and
testing of joints complete as per direction of Engineer in Charge.
Internal work
V GROUND FLOOR
a 15 mm nominal outer dia Pipes MTR 25.00 0.00 0.00 0.00 0.00
b 20 mm nominal outer dia Pipes MTR 20.00 0.00 0.00 0.00 0.00
c 25 mm nominal outer dia Pipes MTR 20.00 0.00 0.00 0.00 0.00
VI FIRST FLOOR
a 15 mm nominal outer dia Pipes MTR 15.00 0.00 0.00 0.00 0.00
b 20 mm nominal outer dia Pipes MTR 15.00 0.00 0.00 0.00 0.00
c 25 mm nominal outer dia Pipes MTR 15.00 0.00 0.00 0.00 0.00
26 Providing all materials, labour, T&P for laying/fixing to wall or ceiling and floor
uPVC solvent weld pipe Sch-80 as per ASTM-D-1785 and pipe fittings of following
nominal bore with clamps including making good the wall, ceiling & floor all
complete as per specification.
External work
V GROUND FLOOR
e 40 mm nominal outer dia Pipes MTR 30.00 0.00 0.00 0.00 0.00
VI FIRST FLOOR
e 40 mm nominal outer dia Pipes MTR 20.00 0.00 0.00 0.00 0.00
f 50 mm nominal outer dia Pipes MTR 50.00 0.00 0.00 0.00 0.00
27 Cutting grooves in pucca floors and walls for taking GI/PVC /CPVC pipes including MTR 50.00 0.00 0.00 0.00 0.00
making good the damages caused with cost of all material,labour, scafolding,
tools, plant, royalty etc. complete in all respects.
28 Supplying all materials, jointing materials, labour and T&P and fixing of uPVC
pressure fittings (Sch-80) as per ASTM-D 2467 (Make: ASTRAL)
a 20 mm EACH 15.00 0.00 0.00 0.00 0.00
b 25 mm EACH 15.00 0.00 0.00 0.00 0.00
c 32 mm EACH 15.00 0.00 0.00 0.00 0.00
d 40 mm EACH 15.00 0.00 0.00 0.00 0.00
e 50 mm EACH 15.00 0.00 0.00 0.00 0.00
29 Supplying all materials,labours,T&P and cutting holes through existing brickwork EACH 30.00 0.00 0.00 0.00 0.00
including making good the damages in cement mortar (1:4) for taking GI /CPVC
/PVC pipes and fittings etc all complete as per PH specification and direction of
Engineer-in-charge.
30 Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene NO 1.00 0.00 0.00 0.00 0.00
cylindrical vertical water storage tanks conforming to IS : 12701--1996 including
cutting holes through the tank and fixing mild steel tubes and fittings and
providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto
a height of 5 metres above ground level and placing the tank to the required
position and providing 1st class Fly ash brickwork in cement mortar (1:6) of
0.46m height in staging and in circular protection wall to support the tank, 12mm
thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and
0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement
concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,
watering, curing, conveyance of all materials to worksite etc all complete as per
specification and direction of the Engineer in charge. Fixing 2000Ltr Roto-moulded
water storage tank (Syntax Make) In first Floor
5 Providing & laying Plain Cement concrete (PCC ) of proportion (1:3:6) in CUM 4.32 0.00 0.00 0.00 0.00
foundation and floors using 4cm (1½”) size clean hard black crusher broken
granite stone metal of approved quality and from approved quarry including
hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to
the required level ramming, watering, curing etc. complete including cost,
conveyance, royalties and taxes of all materials with all labour, cess and T&P
required for the work etc. complete in all respect.
6 Cutting, straightening coiled or bent up M.S. rods, HYSD steel or Tor Steel CUM 2.88 0.00 0.00 0.00 0.00
welding or jointing if necessary, bending, binding, tying the grills as required for
RCC works, and hoisting, lowering and placing in proper position according to
approved designs and drawings including cost, conveyance, loading, unloading,
M.S. rods, HYSD steel or Tor steel and binding wires of 18 to 20 gauge required
for the work and cost of all labour, sundries, T&P and scaffolding complete in all
respect as directed by the Engineer-in-Charge (payment will be made according
to the actual weight of M.S. rod, HYSD steel or Tor steel consumed in the work
and no separate payment will be made towards weight of binding wires which is
to be borne by the contractor at his own cost).
7 Providing strong, rigid, leveled, and plumbed centering and shuttering to required
shape and size , for floors with ply or steel centering materials with all necessary
bracing and tiles and supports with leveling centering covered with plastic sheet
with provisions necessary holes and pockets for electrical conduits, pipes, P.H.
pipes, for hooks or boxes, switch and board insert plates, clamps and extension
bars etc., including dismantling the same after the required interval from the date
of casting including cost of all materials, labour, conveyance, loading and
unloading, taxes, royalties, scaffolding, watering, curing, sundries, tools and
plants, etc., complete as per the direction of the Engineer-in-charge.
a. R.C.C. floor and roof slabs, landings, balconies, projecting sun shades and chajjas SQM 28.80 0.00 0.00 0.00 0.00
upto 4.3m height
8 Reinforcement for RCC work including straightening, cutting, bending, placing in QNTL 2.88 0.00 0.00 0.00 0.00
position and binding all complete. lifting and placing in position as per design
complete including cost of bars , binding wires , including cost of all materials,
labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and
plants, etc. complete as per the direction of the Engineer-in-charge. (linear
measurement will be taken and quantity will be calculated on standard weight for
all heights)-Thermo Mechanically Treated bars
9 Providing Brick work with Fly ash bricks 25cm x 12m x 8cm size having crushing
strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in
cement mortar ( 1 cement: 6 sand), with all necessary projection, splay cutting,
circular moulding, corbelling, etc., including cost of all materials, labour,
conveyance, loading ,and unloadining, taxes, royalties, scaffolding, watering,
curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-
charge.
Foundation & Plinth CUM 25.99 0.00 0.00 0.00 0.00
10 Providing 16 mm. thick cement plaster in all floors at all height with cement SQM 107.58 0.00 0.00 0.00 0.00
mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside
rough surface of brick masonry walls after racking out joints including watering
and curing rounding of corners etc. complete with cost, coveyance, loading and
unloading, royalties and taxes of all materials and cost of all labour, T&P, sundries
and scaffolding required for the work etc. with providing grooves as directed by
the Engineer in charge.
11 Providing neat cement punning over plastered/ concrete surface including SQM 107.58 0.00 0.00 0.00 0.00
watering and curing complete with cost, coveyance, loading and unloading,
royalties and taxes of all materials and cost of all labour, T&P, sundries and
scaffolding required for the work etc. as directed by the Engineer in charge.
12 Providing 6 mm. thick cement plaster in all floors at all height with cement mortar SQM 28.80 0.00 0.00 0.00 0.00
of mix (1:4) with portland slag cement (PSC) finished smooth to inside rough
surface of brick masonry walls after racking out joints including watering and
curing rounding of corners etc. complete with cost, coveyance, loading and
unloading, royalties and taxes of all materials and cost of all labour, T&P, sundries
and scaffolding required for the work etc. with providing grooves as directed by
the Engineer in charge.
13 Supplying & Fixing of Manhole cover ( heavy duty ) 450mm x 450mm water tight NO 2.00 0.00 0.00 0.00 0.00
type including frame cost includes all material,labour, tax,lead tools & plant etc.
complete
14 Supplying all materials,labours,T&P and constructing 1.22m dia and 2.1m depth NO 1.00 0.00 0.00 0.00 0.00
soakway pit with precast RCC rings joined loose,gravel backing in the rear of well
steining,precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg
chips fitted with iron lifting handles including cutting hole in the rings for inlet
pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity
around the pit & painting the iron works, watering, curing, conveyance of all
materials to worksite, payment of royalty, taxes etc all complete as per approved
specification and direction of Engineer-in-charge
Total - SEPTIC TANK & SOAKPIT (E.5-B) 0.00
TOTAL TRANSIT HOUSE PH WORK (E.5-A+E.5-B) 0.00
TRANSIT HOUSE TOTAL (E.1+E.2+E.3+E.4+E.5) 0.00
TOTAL CIVIL_SUBSTATION (A+B+C+D+E) 0.00
CIVIL WORKS _TRANSMISSION LINE
DESCRIPTION OF ITEMS(SCHEDULE-VIIC-LINE) UNIT QUANTITY: BASIC PRICE PER CGST @ 9% PER OGST @ 9% Total F&I TOTAL TOTAL PRICE FOR
Sl. No. CIVIL WORK COMPONENT OF THE WORKS CONTRACT OF FOLLOWING UNIT (Taxable UNIT PER UNIT PRICE PER UNIT THE QUANTITY
EQUIPMENTS (As per Technical Specification) Value) In Rs (INTRA-STATE) (INTRA-STATE) ( In Rs)
1.1 Preliminary survey, Detail survey and resurvey (required for avoiding ROW
problem) including but not limited to taking of levels, profile plotting, tower
spotting ,marking of towers locations at site including showing P&T line, power
line, Railway line, river crossing, roads and submission of route map and survey KM. 8.705 0.00 0.00 0.00 0.00
report etc. The P&T lines and railway lines for a minimum distance of 8 kms on
either side of alignment shall be clearly indicated.
1.2 Check survey including supply of all labour, T&P as per instruction of Engineer in KM.
8.705 0.00 0.00 0.00 0.00
Charge and as per the approved profile.
1.3 Preparation of land schedule with HAL & SAVIK classification on revenue
maps indicating alignment therein duly authenticated by Revenue Inspector &
Tahasildar, enumeration of trees with the help of Forest officer and other KM. 8.705 0.00 0.00 0.00 0.00
prominent features required for alignment of the proposed 132 KV line. Final
route to be plotted on 1:50000 topo sheet for approval.
3.1.3 Cutting bending hooking, fixing and binding in poisition of MS bars for
rainforcement of foundation concrete of towers including supply of wire for MT 3 0.00 0.00 0.00 0.00
binding With supply of steel rod(TATA/RINL/SAIL Make) and head loading. No
other make of steel shall be allowed.
4 PILE FOUNDATION (UNDER-REAM PILE) BORING &CONCRETE WORKS
Boring for under ream cast-in-Situ piling, with Manual Auger method or by using
Motor driven Machinery ,including supply of Bentonite required for as per
4.1 required procedure depending on the length of the bore stabilization bore of
required diameter bore holes as per required design length of the bore.
Supply of Steel of different size (as per design ) with cutting, bending,
welding,binding in position of M.S.Rod for reinfocement of foundation concrete of
4.4.3 Pile Risers including supply of binding wire With supply of steel rod ( MT. 0 0.00 0.00 0.00 0.00
TATA/RINL/SAIL make only) and head loading. No other make steel shall be
accepted.
Supply of borrowed earth/morrum for back filling for
4
foundation/revertment works
4.1 Beyond 30 mtr lead CUM 100 0.00 0.00 0.00 0.00
4.2 beyond 100 mtr lead CUM 300 0.00 0.00 0.00 0.00
SHORING & SHUTTERING- Required in special locations (wet / submerged) of
5 open cast/shallow type foundations with supply of all materials,T&P and Labour. SQ.MTR. 1000 0.00 0.00 0.00 0.00
7.1 Excavation in all type of soil including rock & back filling including supply of sand
CUM 200 0.00 0.00 0.00 0.00
with back filling.
7.2 Lean concrete in the ratio 1:3:6(grade-M10) including supply of sand & chips etc.
CUM 30 0.00 0.00 0.00 0.00
7.3 PCC in the ratio 1:2:4(grade-M15) as above CUM 10 0.00 0.00 0.00 0.00
7.4 RR masonary work in the ratio 1:5 CUM 200 0.00 0.00 0.00 0.00
8 Approval for PTCC , railway crossing, NHAI, Forest, Water and other
Statutory/Govt. bodies clearances (except payment of statutory fees) has to be
obtained by submitting the required documents to the concerned department
through OPTCL. The documents for above clearances including required drawings Lot 1 0.00 0.00 0.00 0.00
etc has to be submitted by the contractor within 3 months of award of contract.
Beyond the above period L.D as applicable & the amount shall be deducted as
specified in the specification.
9 RIGHT OF WAY COMPENSATION
9.1 Per location for foundation and erection of tower Per Loc 30 0.00 0.00 0.00 0.00
9.2 Per Kilometer for stringing Per Km. 8.705 0.00 0.00 0.00 0.00
TOTAL OF (Civil Work) (PART-B)_TRANSMISSION LINE 0.00
TOTAL OF CIVIL WORKS COMPONET OF WORKS CONTRACT PRICE_ SS
& TRANSMISSION LINE (A+B) 0.00
NOTE
1 Before filling up rate/amount etc. in the schedules bidders are requested to read carefully the instruction given in Vol-I of Bidding Document.
2 Bidders are required to fill up only blue shaded cells.
3 Bidders are requested to not leave any column blank. If any column is left blank it shall be considered that amount against those items are included in any other item and the total amount for that item shall be calculated as free of
4 Basic Price (taxable value) for supply includes Packing & Forwarding, freight & insurance etc. excluding GST with full Input Tax Credit)
ODISHA POWER TRANSMISSION CORPORATION LIMITED
Total of GST and any other Taxes and Duties for Schedule VIIA_ Transmission line
1.2.2
Supply of Equipment/materials in INR
TOTAL of Supply Component Schedule VIIA _TRANSMISSION LINE
0.00
(Equipment/materials).
1.3 Schedule VIIA_MANDATORY SPARES
Total Basic Price (Taxable value) exclusive of GST and any other taxes & duties for
1.3.1
Schedule VIIA_ Mandatory Spares Supply of Equipment/materials in INR
Total of GST and any other Taxes and Duties for Schedule VIIA_ Mandatory Supply of
1.3.2
Equipment/materials in INR
TOTAL of Supply Component Schedule VIIA _MANDATORY
0.00
SPARES(Equipment/materials).
TOTAL of Supply Component- Schedule VIIA _(SS+LINE+MANDATORY
1.3 0.00
SPARES) (Equipment/materials ).
2.0 PART -II ERECTION COMPONENT OF THE WORKS CONTRACT
2.1 Schedule VIIB_Sub-station Erection
Total Basic Price (Taxable value) exclusive of GST and any other taxes and Duties for
2.1.1
Schedule VIIB_Sub-station Erection (Electrical Works) Equipment/materials in INR
Total of GST and any other Taxes and Duties for Schedule VIIB_Substation Erection
2.1.2
(Electrical Works) Equipment/materials in INR
TOTAL of Schedule VIIB_Substation Erection Charges 0.00
2.2 Schedule VIIB_Line Erection (ELECTRICAL WORKS )
Total Basic Price (Taxable value) exclusive of GST and any other taxes and Duties for
2.2.1
Schedule VIIB_Transmission line Erection (Electrical Works) Equipment/materials in INR
Total of GST and any other Taxes and Duties for Schedule VIIB_Transmission line
2.2.2
(Electrical Works) Equipment/materials in INR
TOTAL of Schedule VIIB_Line Erection Charges 0.00
TOTAL of Erection Component- Schedule VIIB _(SS+LINE) (Equipment/materials
2.3 0.00
).
3.0 PART -III CIVIL WORK COMPONENT OF THE WORKS CONTRACT
3.1 Schedule VIIC_Sub-station Civil Works
Total Basic Price (Taxable value) exclusive of GST for CIVIL WORKS in Schedule
3.1.1
VIIC_Sub-Station Equipment/materials in INR
Total of GST and anyother Taxes and Duties for CIVIL WORKS in Schedule VIIC_Sub-
3.1.2
Station Equipment/materials in INR
Total of CIVIL WORKS for Schedule VIIC_Sub-Station 0.00
3.2 Schedule VIIC_Line Civil Works
Total Basic Price (Taxable value) exclusive of GST for CIVIL WORKS in Schedule
3.2.1
VIIC_Transmission line Equipment/materials in INR
Total of GST and anyother Taxes and Duties for CIVIL WORKS in Schedule
3.2.2
VIIC_Transmission line Equipment/materials in INR
Total of CIVIL WORKS for Schedule VIIC_Line 0.00
3.3 TOTAL of Schedule VIIC_CIVIL WORKS 0.00
4.0 TOTAL WORKS CONTRACT PRICE IN INR 0.00
5.0 TOTAL DISCOUNT OFFERED ON OWRKS CONTRACT IN INR