Corning® Laboratory Stirrer/

Hot Plate
Instruction Manual

Catalog Number
230V 230V 230V
Model No. Description 120V 100V (Non-Europe) (Europe) (China)
PC-400D Hot Plate 6795-400D 6797-400D 6798-400D 6796-400D 6799-400D
PC-410D Stirrer 6795-410D 6797-410D 6798-410D 6796-410D 6799-410D
PC-420D Stirring Hot Plate 6795-420D 6797-420D 6798-420D 6796-420D 6799-420D
PC-600D Hot Plate 6795-600D 6797-600D 6798-600D 6796-600D 6799-600D
PC-610D Stirrer 6795-610D 6797-610D 6798-610D 6796-610D 6799-610D
PC-620D Stirring Hot Plate 6795-620D 6797-620D 6798-620D 6796-620D 6799-620D
External Temperature
6795PR (all models)
Controller
Table of Contents
1.0 Safety Information...............................................................................................................................1

2.0 Operating Conditions...........................................................................................................................2

3.0 Product Controls and Indicators........................................................................................................3

4.0 Product Connections............................................................................................................................3

5.0 Stirring Instructions.............................................................................................................................4

6.0 Heating Instructions............................................................................................................................4

7.0 Heating Operation................................................................................................................................6

8.0 Repair.......................................................................................................................................................7

9.0 Maintenance..........................................................................................................................................7

10.0 Accessories..............................................................................................................................................8

11.0 Technical Specifications.......................................................................................................................9

12.0 Frequently Asked Questions........................................................................................................... 10

13.0 Limited Warranty............................................................................................................................... 11

14.0 Equipment Disposal.......................................................................................................................... 11


1.0 Safety Information
This instruction manual contains important operating and maintenance instructions that
must be read, understood, and followed by the product user. Failure to use this product
according to this instruction manual may degrade or defeat the protection normally provided
by this product. Read this instruction manual prior to product use and keep this instruction
manual for future reference.
Product Voltages
Hot plates, stirrers, and stirring hot plates are available in different voltages. Before initial
use, check that the unit you received is the correct voltage for your location.

Symbols and Conventions


CAUTION: Risk of Danger: Cautions there is material in the instruction manual
which must be read, understood, and followed in order to preserve product
safety features.

CAUTION: Hot Surface: Cautions that the top plate is too hot to touch

Indicates that the unit is plugged into power supply.

Indicates that the accessory external temperature controller is properly plugged


into the unit.

Safety Precautions

Personal Injury
 If the equipment is used in a manner not specified by this manual,
the equipment may become unsafe to operate, could harm the user
or the device, and may void the warranty. Changes or modifications not
expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
 This product is designed for use in laboratory environments by persons
knowledgeable in safe laboratory practices.
 Always wear safety glasses and other appropriate protective equipment when
operating this product.

Electric Shock
 This product must be connected to a grounded power outlet for safe
functioning.
 Use only the power cord supplied with the product.
 Position the product for use so the power cord can be easily disconnected
without having to move the product.
 Disconnect the power cord before moving or cleaning the unit.

Instruction Manual 1
Product Damage
 Keep the product dry and clean.
 Do not immerse the product for cleaning.
 The ceramic top may break if impacted.
 The maximum gross weight placed on the top surface must not exceed 25 lbs.
(11 kg).
 These units are not explosion- or spark-proof.
 Do not heat or stir volatile or flammable materials.
 Do not operate this product near volatile or flammable materials.
 Do not use this product with a metal vessel.
 The temperature probe must always be inside the media to close the heating
control loop and should not be operated unattended.
 Corning strongly recommends to not leave the product unattended while
operating.
 Corning recommends to disconnect the unit when not in use.

2.0 Operating Conditions


Corning® hot plates, stirrers, and stirring hot plates, are designed to be safe when used under
the following conditions:
 Product should be placed on a flat surface at least 12 in. (30.5 cm) from walls, 48 in.
(122 cm) from ceilings, and 12 in. (30.5 cm) from other stirrers if using multiple units
 Indoor use
 Pollution Degree 2
 Altitude up to 2,000 meters
 Ambient temperatures of 5°C to 40°C
 Ambient humidity of ≤80% at 31°C, decreasing linearly to 50% relative humidity at 40°C
 Installation Category II
 Protection Class IP21

2 CORNING LABORATORY STIRRER/HOT PLATE


3.0 Product Controls and Indicators

1
7 6

3 5

2 4

1. Power Indicator: Illuminates at all times when the product is properly connected to input power.
2. Stir Control Knob: Turn the knob all the way counterclockwise to turn off stirring function.
Turn the knob clockwise to set desired stirring speed.
3. Stirring Speed Display: Shows the speed set for stirring.
4. Heat Control Knob: Turn the knob all the way counterclockwise to turn off heating
function. Turn the knob clockwise to set the desired heating temperature.
5. Heating Temperature Display: Shows the temperature set for heating.
6. Hot Top Indicator: Illuminates when the temperature of the top is too hot to touch
(greater than approx. 60°C).
7. Temperature Probe In-Use Indicator: Illuminates when the external temperature probe
is connected to the unit.

4.0 Product Connections


1. Power Cord Input: Connect the supplied power cord into this connector.
2. External Temperature Controller Input: Connect the optional External Temperature
Controller (Cat. No. 6795PR) into this connector.

2 1

To Connect/Disconnect the External Temperature Controller


3. Turn the Stir Control Knob and Heat Control Knob to the OFF position.
4. Disconnect power cord.
5. Insert/remove external temperature controller connector into/from the input connector.
6. Reconnect power cord.
7. Product is now ready for use.

Instruction Manual 3
5.0 Stirring Instructions
For Models: PC-410D, PC-420D, PC-610D, PC-620D
1. Fill the vessel with solution to be stirred.
2. Place the stir bar into the vessel.
3. Place the vessel in the center of the top surface.
4. Turn Stir Control Knob until the Stirring Speed Display shows the desired speed. The speed
setting can be adjusted according to the table below.
Operating Range Adjustable
(rpm) Increment (rpm)
60 - 100 5
100 - 200 10
200 - 400 20
400 - 1,150 50

 Flashing Display: The number will FLASH when the actual stirring speed is not at set
speed.
 Constant Display: The number will not flash when the actual stirring speed is at the set
speed. The number will remain constantly ON when the actual stirring speed is at the
set speed.
5. When desired stirring is complete, turn the Stir Control Knob to the OFF position. Allow
stir bar to cease rotation before removing the vessel from the unit.
6. Heating and stirring can be performed simultaneously with the PC-420D and PC-620D
models, which offer both heating and stirring functions.
NOTE: The viscosity of the stirred material will affect the ability of the stir bar to remain
coupled to the rotating ring magnet. Materials of high viscosity must be stirred at slower
speed settings.

6.0 Heating Instructions


Without the External Temperature Controller for Models: PC-400D, PC-420D, PC-600D,
and PC-620D
1. Fill the vessel with solution to be heated.
2. If using a PC-420D or PC-620D model and the stirring function, place the stir bar into
the vessel.
3. Place vessel in the center of the top surface.
4. Turn Heat Control Knob until the Heating Temperature Display shows the desired
temperature. The temperature setting can be adjusted in 5°C increments.
 Flashing Display: The number shown on the Heating Temperature Display will FLASH
when the actual heating temperature is not at the set temperature.
 Constant Display: The number shown on the Heating Temperature Display will remain
constantly ON when the actual heating temperature is at the set temperature.
 Hot Top Indicator: The Hot Top Indicator will be ON at all times when the temperature
of the top surface is too hot to touch (greater than approx. 60°C).

4 CORNING LABORATORY STIRRER/HOT PLATE


 The Hot Top Indicator will FLASH when the Heat Control Knob is turned OFF but the top
surface is still too hot to touch.
 The Hot Top Indicator will be OFF when the temperature of the top is less than approx. 60°C.
CAUTION: The Hot Top Indicator will turn OFF when the power cord is
disconnected from the product even if the temperature of the top surface
is still too hot to touch.

With the External Temperature Controller (Corning 6795PR) for Models: PC-400D, PC-420D,
PC-600D, PC-620D, and 6795PR
1. Connect the External Temperature Controller to the connector on the back of the unit.
 Temperature Probe in Use Indicator: This will illuminate when the External Temperature
Controller is properly connected.
2. Fill the vessel with solution to be heated.
3. If using a PC-420D or PC-620D model and the stirring function, place the stir bar into the vessel.
4. Place the vessel in the center of the top surface.
5. Insert the tip of the External Temperature Probe into the solution (see section 10.0
diagram for proper usage).
 The tip should be located in the center of the vessel and at approximately one-half
of the depth of the solution.
6. Secure the position of the External Temperature Controller by using a ring stand/support
rod and clamp.
 Ensure the cable of the External Temperature Controller does not come into contact with
the heating surface.
7. Turn the Heat Control Knob until the Heating Temperature Display shows the desired
heating temperature.
 Flashing Display: The number shown on the Heating Temperature Display will FLASH
when the actual heating temperature is not at the set temperature.
 Constant Display: The number shown on the Heating Temperature Display will remain
constantly ON when the actual heating temperature is at the set temperature.
 Hot Top Indicator: The Hot Top Indicator will be ON at all times when the temperature
of the top surface is too hot to touch (greater than approx. 60°C).
 The Hot Top Indicator will FLASH when the Heat Control Knob is turned OFF but the top
surface is still too hot to touch.
 The Hot Top Indicator will be OFF when the temperature of the top is less than approx. 60°C.
CAUTION: The Hot Top Indicator will turn OFF when the power cord is
disconnected from the product even if the temperature of the top surface is still
too hot to touch.

Instruction Manual 5
7.0 Heating Operation
7.1 Principles
The heating element and a temperature sensor are located just beneath the ceramic top
surface of the product. The microprocessor-controlled heat, generated by the heating
element, is based upon the sensor temperature and the value set on the Heating
Temperature Display. When the sensor temperature is not within range of the value set on
the display, the display will FLASH. When the sensor temperature is within range, the value
displayed will remain constantly ON.
The Heating Temperature Display does not indicate the actual temperature of materials
placed on top of the product or the actual temperature of the ceramic top surface.
The following table shows a typical difference between the temperature set on the Heating
Temperature Display and the actual temperature measurement of the ceramic top surface.
Temp. Set on Actual Top Surface Temp. Set on Actual Top Surface
Display (°C) Temp. (°C) Display (°C) Temp. (°C)
50 45 350 285
100 85 400 325
150 125 450 365
200 165 500 405
250 205 550 440
300 245

(This information was taken using a 6795-420D with no top load in 20°C ambient conditions).
Using the External Temperature Controller (Cat. No. 6795PR) enables precision temperature control
of materials placed in vessels on top of the product.
When the External Temperature Controller is connected to the product, the closed loop
control process is extended to include temperature input from the External Temperature
Controller. The microprocessor-controlled heat, generated by the heating element, is based
upon the sensor temperature located in the tip of the External Temperature Controller
and the value set on the Heating Temperature Display. When the sensor temperature is
not within range of the value set on the display, the display will FLASH. When the sensor
temperature is within range, the value displayed will remain constantly ON.
To directly control the temperature of liquid in a vessel on the top surface, place the External
Temperature Controller into the liquid and connect the Controller to the product. The
Heating Temperature Display shows the temperature of the liquid and can be used to adjust
the temperature of the liquid. See Section 10.0 for ordering information.
CAUTION: The top surface and the vessel used may be at substantially higher
temperatures than indicated by the setting on the Heating Temperature Display
as the controller regulates the liquid temperature inside the vessel.

7.2 Safety
The microprocessor-controlled system has built-in error routines to detect product operation
in some unfavorable conditions. The type of error routines which may be active in a product
varies depending upon the functionality of the model and the operating software version.
If an error routine is engaged, the product will typically shut down. Some error routines will

6 CORNING LABORATORY STIRRER/HOT PLATE


display an error code number in the left digital location of the Heating Temperature Display
when the product is shut down. For more information on error codes, contact Corning
Scientific Support at 978.442.2200.
A product shut down by an error routine must be disconnected and reconnected to mains input
before it can be used again. Please contact Corning Life Sciences or a Corning authorized repair
facility (visit www.corning.com/lifesciences) if a product does not reset from the error routine
shut down or if it continues to shut down after resetting.
CAUTION: Error routines built into these products do not substitute the need to
use these products per the specified operating conditions and according to safe
laboratory practices. There are potential failure modes in product functionality or
in the process of use that could result in uncontrolled or unexpected heating of
the top surface. Reaction plans should be developed and safety precautions put
in place based on the worst case scenario that any materials placed on the top
surface could be subjected to a continuous supply of heat, raising the material
temperature to levels in excess of 550°C.

8.0 Repair
There are no direct user serviceable components inside this series of products.
Please contact Corning or a Corning authorized repair facility for repair or maintenance issues.

9.0 Maintenance
Power

CAUTION: Disconnect power to the product by unplugging the power cord before
performing any maintenance or inspection procedures.

 Inspect the power cord regularly and replace if damaged. Use only replacement power
cords available from Corning or Corning authorized product distributors.
 Ceramic Top Plate
 These products are supplied with a Pyroceram® top that is easy to clean and highly
resistant to scratches, corrosion, and chemical attack.
 The ceramic top may break during use if not properly maintained.
 Keep the ceramic top clean. A nonabrasive cleaner may be used to clean the ceramic top.
 Inspect the ceramic top for damage during cleaning.
 Discontinue product use if the ceramic top is chipped, etched, or shows excessive scratching.
 Contact Corning or a Corning authorized repair facility for a top replacement.
 General
 It is important to keep this product dry and clean.
 Remove minor exterior liquid spills promptly.
 Clean exterior surfaces with a nonabrasive cleaner. Do not reconnect product to power
input until all cleaned surfaces have dried.
 If liquid or wet solid material gets inside the product, immediately disconnect the power
to the product and discontinue use. Contact Corning for additional instructions regarding
interior spills.

Instruction Manual 7
10.0 Accessories
Support rod
(440129)

Boss head clamp


(440140)
Holding rod
(440141)

External
temperature
controller
(6795PR)

Stir bar retriever


(6970SR)

Accessories (Shown with Cat. No. 6795-420D)

Cat. No. Description


6795PR External temperature controller for digital display hot plates and stirring hot plates.
Use with all PC-400D, 420D, 600D, and 620D models.
440129 Vertical support rod. Supplied as two 9 in. (22.86 cm) rods which can be screwed
together. Use with all PC-400D, PC-410D, PC-420D, PC-600D, PC-610D, PC-620D
series products. Stainless steel.
400430 PTFE-coated magnetic stir bar, 39 x 2 in. (1 x 5.1 cm) – recommended size for all PC-
610D and 620D models
401435 PTFE-coated magnetic stir bar, 39 x 1 in. (1 x 2.5 cm) – recommended size for all PC-
410D and 420D models
6970SR Stir bar retriever, polypropylene

8 CORNING LABORATORY STIRRER/HOT PLATE


Cat. No. Description
6795KIT Corning® Digital Display Hot Plate and Stirring Hot Plate Accessory Kit
This accessory kit is designed for all Corning digital display hot plates and stirring
hot plates (Models PC-400D, PC-420D, PC-600D, PC-620D).
This kit includes: external temperature controller (Cat. No. 6795PR), vertical support
rod (Cat. No 440129), Supplied as two 9 inch (22.9 cm) support rods that can be
screwed together (18 inches), stir bar retriever (Cat. No. 6970SR).
6795-420KIT Corning 5 x 7 in. Top PC-420D Stirring Hot Plate Kit with Digital Displays, 120V/60Hz
This kit includes: One stirring hot plate (Cat. No. 6795-420D), external temperature
controller Cat. No. 6795PR, vertical support rod (Cat. No 440129). Supplied as two
9 inch (22.9 cm) support rods that can be screwed together (18 inches), stir bar
retriever (Cat. No. 6970SR).
6795-620KIT 6795-620KIT Corning 10 x 10 in. Top PC-620D Stirring Hot Plate Kit with Digital
Displays, 120V/60Hz
This kit includes: One stirring hot plate (Cat. No. 6795-620D), external temperature
controller (Cat. No. 6795PR), vertical support rod (Cat. No 440129). Supplied as two
9 inch (22.9 cm) support rods that can be screwed together (18 inches), stir bar
retriever (Cat. No. 6970SR).

Available for purchase separately and not included in the kits


440140 Boss head clamp. Use for connecting the holding rod (Cat. No. 440141) at a 90° angle
to the support rod (Cat. No. 440129). Aluminum.
440141 Holding rod. Use for holding the external temperature controller (Cat. No. 6795PR)
in position. Aluminum.

11.0 Technical Specifications


Power
120V/60Hz 100V/60Hz 230V/50Hz 230V/50Hz Stir Range
Model No. (6795 Cat. Nos.) (6797 Cat. Nos.) (6796 Cat. Nos.) (6798 Cat. Nos.)1 Temp. Range2 (rpm) Weight
5°C-550°C 5.5 lbs.
PC-400D 665W/5.5A 685W/6.9A 635W/2.7A 635W/2.7A —
(41°F-1,022°F) (2.5 kg)
6.2 lbs.
PC-410D 15W/0.1A 15W/ 0.15A 15W/ 0.06A 15W/0.06A — 60-1,150
(2.8 kg)
5°C-550°C 6.2 lbs.
PC-420D 675W/5.6A 695W/6.9A 645W2.8A 645W/2.8A 60-1,150
(41°F-1,022°F) (2.8 kg)
5°C-550°C 10.0 lbs.
PC-600D 1043W/8.7A 1043W/10.5A 1043W/4.5A 1043W/4.5A –
(41°F-1,022°F) (4.5 kg)
11.5 lbs.
PC-610D 73W/0.7A 78W/0.8A 73W/0.3A 73W/0.3A — 60-1,150
(5.2 kg)
5°C-550°C 11.5 lbs.
PC-620D 1113W/9.3A 1113W/11.2A 1113W/4.8A 1113W/4.8A 60-1,150
(41°F-1,022°F) (5.2 kg)

Cat. Nos. beginning with 6798 in 230V are non-European configuration models.
1

The Temperature Range using the External Temperature Controller is 5°C to 200°C (41°F to 392°F).
2

Model No. Top Plate Size Dimensions


PC-400D/410D/420D 5 x 7 in. 10.8 x 7.8 x 4.3 in.
(12.7 x 17.8 cm) (27.5 x 19.7 x 10.9 cm)
PC-600D/610D/620D 10 x 10 in. 4.625 x 11 x 15.375 in.
(25.4 x 25.4 cm) (11.75 x 19.7 x 39.05 cm)

Instruction Manual 9
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the centrifuge is operated in a
commercial environment. The equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the user manual, may cause harmful
interference to radio communications. Operation of equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the
interference.
CAUTION: This equipment is not intended for use in residential environments and may not
provide adequate protection to radio reception in such environments.
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme NMB-001 du Canada.

12.0 Frequently Asked Questions


 I have a beaker of water on my hot plate and the temperature is set for 550°C. Why does
the display setting blink and not remain constant?
The display will blink at any time when the temperature sensor is not within range
of the set temperature value. The temperature measured by the sensor is a composite of
the temperature of the heating element located beneath the sensor, the ceramic top above
the sensor, and the very small air space around the sensor. Water requires a substantial
amount of heat in order to boil yet remains at a constant temperature of 100°C for the
duration of the boiling process. Although the heating element is producing maximum
heat at the 550°C setting, the water consumes this heat so quickly during the boiling
process that the heat is unable to raise the temperature measured by the sensor to within
the range of the 550°C set value.
 How long does it take to bring a beaker of water to a boil?
Using a 600 mL beaker with 400 mL of water at 25°C, it takes approximately 15 minutes to
bring the water to a full, rolling boil.
 Can I use a metal tray on top of my Corning® hot plate?
No. The metal will act as a heat sink, and have a high probability of creating an abnormal
heating condition. If an abnormal condition is detected, the product will shut down.
A metal vessel will also scratch the ceramic top plate.
 The stir bar keeps decoupling. Why and what can I do to stop this?
These units are programmed to minimize decoupling. However, liquid viscosity, stir bar
magnetic strength, vessel used, and speed changes can cause decoupling. High viscosity
liquids must be stirred at slower speed settings. The magnetic strength of stir bars can
weaken over time and may need to be replaced. The vessels used need to have thin, flat
bottoms to insure optimal performance. Rapid decreases in stir speed can cause decoupling
as the magnet slows down quicker than the stir bar and the liquid.
 What size vessel should I use?
The vessels used on the top of a hot plate must not be larger than the top plate.

10 CORNING LABORATORY STIRRER/HOT PLATE


13.0 Limited Warranty
Corning Incorporated (Corning) warrants that this product will be free from defects in material
and workmanship for a period of two (2) years from date of purchase. CORNING DISCLAIMS
ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. Corning’s sole
obligation shall be to repair or replace, at its option, any product or part thereof that proves
defective in material or workmanship within the warranty period, provided the purchaser
notifies Corning of any such defect. Corning is not liable for any incidental or consequential
damages, commercial loss, or any other damages from the use of this product.
This warranty is valid only if the product is used for its intended purpose and within the
guidelines specified in the supplied instruction manual. This warranty does not cover damage
caused by accident, neglect, misuse, improper service, natural forces, or other causes not
arising from defects in original material or workmanship. This warranty does not cover motor
brushes, fuses, light bulbs, batteries, or damage to paint or finish. Claims for transit damage
should be filed with the transportation carrier.
In the event this product fails within the specified period of time because of a defect in
material or workmanship, contact Corning Customer Service at: USA/Canada 1.800.492.1110,
outside the U.S. +1.978.442.2200, visit www.corning.com/lifesciences, or contact your local
support office.
Corning Customer Service will help arrange local service where available or coordinate
a return authorization number and shipping instructions. Products received without proper
authorization will be returned. All items returned for service should be sent postage prepaid
in the original packaging or other suitable carton, padded to avoid damage. Corning will not
be responsible for damage incurred by improper packaging. Corning may elect for onsite
service for larger equipment.
Some states do not allow limitation on the length of implied warranties or the exclusion
or limitation of incidental or consequential damages. This warranty gives you specific legal
rights. You may have other rights which vary from state to state.
No individual may accept for, or on behalf of Corning, any other obligation of liability,
or extend the period of this warranty.
For your reference, make a note of the model number, serial number, date of purchase,
and supplier here.
Model No. _________________________ Date Purchased__________________________
Serial No. __________________________ Supplier________________________________

14.0 Equipment Disposal


According to Directive 2012/19/EU of the European Parliament and Council
of 4th July 2012 on waste and electronic equipment (WEEE) as amended, this
product is marked with the crossed-out wheeled bin and must not be disposed
of with domestic waste.
Consequently, the buyer shall follow the instructions for reuse and recycling
of waste electronic and electrical equipment (WEEE) provided with the
products and available at the following link: www.corning.com/weee.

Instruction Manual 11
Warranty/Disclaimer: Unless otherwise specified, all products are for research use or general
laboratory use only.* Not intended for use in diagnostic or therapeutic procedures. Not for
use in humans. These products are not intended to mitigate the presence of microorganisms
on surfaces or in the environment, where such organisms can be deleterious to humans or
the environment. Corning Life Sciences makes no claims regarding the performance of these
products for clinical or diagnostic applications. *For a listing of US medical devices, regulatory
classifications or specific information on claims, visit www.corning.com/resources.
Corning’s products are not specifically designed and tested for diagnostic testing. Many
Corning products, though not specific for diagnostic testing, can be used in the workflow and
preparation of the test at the customers discretion. Customers may use these products to
support their claims. We cannot make any claims or statements that our products are approved
for diagnostic testing either directly or indirectly. The customer is responsible for any testing,
validation, and/or regulatory submissions that may be required to support the safety and
efficacy of their intended application.

NORTH AMERICA EUROPE


t 800.492.1110 [email protected]
t 978.442.2200 France
Corning Incorporated t 0800 916 882
Life Sciences ASIA/PACIFIC
Germany
Australia/New Zealand t 0800 101 1153
www.corning.com/lifesciences
t 61 427286832
The Netherlands
Chinese Mainland t 020 655 79 28
t 86 21 3338 4338
United Kingdom
India t 0800 376 8660
t 91 124 4604000
All Other European
Japan Countries
t 81 3-3586 1996 t +31 (0) 206 59 60 51
Korea
t 82 2-796-9500 LATIN AMERICA
Singapore [email protected]
t 65 6572-9740 Brazil
Taiwan t 55 (11) 3089-7400
t 886 2-2716-0338 Mexico
t (52-81) 8158-8400

For a listing of trademarks, visit www.corning.com/clstrademarks. All other trademarks are the property of their respective owners.
© 2011-2023 Corning Incorporated. All rights reserved. 10/23 CLS-EQ-091DOC REV3

You might also like